Product TypeCompressed Air Flow Sensor
ModelSFAM-90-5000L-TG1-2SA-M12
Measuring Range90 ... 5000 L/min (standard conditions)
Output Signal2 x switching outputs (PNP/NPN) + analog output 4...20 mA
Operating Voltage24 V DC (10...30 V DC)
Process ConnectionG1/2" (TG1)
Electrical ConnectionM12x1, 5-pin
Pressure RatingMax. 10 bar
MediumCompressed air, inert gases
Measuring PrincipleThermal (calorimetric)
Accuracy±3% of measured value ±0.3% of full scale
Repeatability±0.5% of measured value
Response TimeTyp. 100 ms
Temperature Range (Medium)-10 ... 50 °C
Ambient Temperature-10 ... 60 °C
Protection ClassIP65
Material (Housing)Aluminum, anodized
Material (Seals)NBR
Dimensions (L x W x H)Approx. 90 x 60 x 60 mm
WeightApprox. 250 g
MaintenanceNo moving parts; clean with a damp cloth if needed
RepairabilityNon-repairable; replace unit if defective

Frequently Asked Questions - SFAM-90-5000L-TG1-2SA-M12 Festo

How do I connect the SFAM-90-5000L-TG1-2SA-M12?
Use a 5-pin M12 connector. Pin 1: +24V, Pin 2: analog output, Pin 3: 0V, Pin 4: switching output 1, Pin 5: switching output 2. Refer to the manual for wiring details.
What is the measuring range of this flow sensor?
The sensor measures flow from 90 to 5000 L/min under standard conditions (20 °C, 1 bar absolute).
Can I use the SFAM-90-5000L with liquids?
No, it is designed for compressed air and inert gases only. Do not use with liquids.
How do I clean the flow sensor?
Clean the exterior with a soft, damp cloth. Avoid solvents. The sensing element is internal and does not require cleaning under normal conditions.
What is the output signal type?
It has two PNP switching outputs (configurable as NPN) and a 4-20 mA analog output proportional to flow.
How do I set the zero point?
With zero flow, press and hold the 'Set' button for 3 seconds until LED flashes. The zero point is saved automatically.
What is the maximum working pressure?
The maximum pressure is 10 bar. Exceeding this may damage the sensor.
Can the sensor be mounted in any orientation?
For best accuracy, mount horizontally with the display facing up. Refer to manual for orientation effects.
How do I interpret the analog output?
The 4-20 mA output scales linearly with flow: 4 mA = 0 L/min, 20 mA = 5000 L/min. Use a PLC or multimeter to read the current.
What do the LEDs indicate?
Green LED: power on. Yellow LED: switching output active. Flashing red: error or overrange.

User questions about SFAM-90-5000L-TG1-2SA-M12 Festo

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Measurement in PDF format for free! Find your manual SFAM-90-5000L-TG1-2SA-M12 - Festo and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. SFAM-90-5000L-TG1-2SA-M12 by Festo.

USER MANUAL SFAM-90-5000L-TG1-2SA-M12 Festo

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Festo

Model : SFAM-90-5000L-TG1-2SA-M12

Category : Measurement