H4 - Wristwatch HYT - Free user manual and instructions
Find the device manual for free H4 HYT in PDF.
| Type | Wristwatch |
| Brand | HYT |
| Model | H4 |
| Case Material | Titanium |
| Case Diameter | 48 mm |
| Case Thickness | 17.5 mm |
| Weight | Approx. 100 g |
| Movement | Mechanical automatic |
| Power Reserve | 65 hours |
| Water Resistance | 30 m (3 ATM) |
| Crystal | Sapphire with anti-reflective coating |
| Strap Material | Rubber or alligator leather |
| Functions | Fluid hour display, minutes, seconds, power reserve indicator |
| Winding | Screw-down crown for manual winding and time setting |
| Maintenance | Clean with soft, dry cloth; avoid contact with chemicals |
| Service Interval | Every 3-5 years |
| Spare Parts & Repairability | Contact HYT authorized service center |
Frequently Asked Questions - H4 HYT
User questions about H4 HYT
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Wristwatch in PDF format for free! Find your manual H4 - HYT and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. H4 by HYT.
USER MANUAL H4 HYT
THE HYDRO MECHANICAL HOROLOGISTS
HYT
INSTRUCTION MANUAL AND GUARANTEE
H4
Thank you and congratulations!
With this HYT watch, you have joined the age of Hydro-Mechanical Horology.
HYT represents the link between traditional watchmaking and fluid mechanics.
Whichever model you have chosen, it will be part of the same uncompromising HYT philosophy, which is to offer the best in traditional watchmaking combined with unlimited hydro-mechanical creativity.
Grégory Dourde
CEO

GUARANTEE
In this manual, you can find the basic instructions for using and maintaining your watch.
Each HYT watch bears an individual identification number, which guarantees both its authenticity, and that all the work involved in its creation has been supervised by a master watchmaker.
Each HYT watch is equipped with a fluidic module. The fluidic module is the device which enables the time to be displayed via the meniscus 1 . The meniscus marks the boundary between the two immiscible fluids in the capillary 3 . The watch movement drives the module via the bellow 2 fixed on the main plate. Only a professional watchmaker approved by HYT can replace this fluidic system. It bears a unique serial number.
The card you received when you purchased your watch is the electronic guarantee certificate for your HYT watch.
The QR Code on the front of your card gives you access to unique and interactive content, once you have downloaded the app. This content explains the correct way to use your watch, with specific videos and texts.
The guarantee is activated upon purchase in our network of approved HYT retailers. You must present your activated guarantee card to be entitled to the guarantee.
If following your purchase you have not received a confirmation e-mail, please go to www.hytwatches.com/lounge. Then select the market place corresponding to your mobile.
The app will ask you to scan the QR Code and enter your e-mail, in order to send you a password.
By downloading this app, you will be able to contact our customer services in a single click in case of an incident or if you have any questions.
Your HYT watch is guaranteed against all manufacturing defects for five years from the date it was purchased, if the watch was purchased from an approved HYT retailer. This guarantee does not however cover damage caused by incorrect handling or improper use of the watch.
For any service, repair or maintenance procedure, please ensure you only use retailers approved by HYT or our customer services.
You can find the list of our network of approved retailers and our customer services on our website www.hytwatches.com.
Any repair or maintenance work carried out by third parties who have not been approved by HYT will automatically void the guarantee. Any damage caused will then have to be repaired at your expense.
PRECAUTIONS FOR USEPRECAUTIONS FOR USE
Your HYT watch is set and ready to be worn.
The meniscus 1 in the capillary 3 displays the time continuously while the watch is on your wrist, even if you wear it in extreme temperatures (0°C to +50°C).

Important : If you plan to not wear the watch for a while, the coloured liquid has to be stored in its own reservoir (on the left bellows 2 ).
To do this, unscrew the crown and pull it out to position C (time setting). Allow the coloured liquid to move into "Zone II" until it starts its retrograde (ensure the time needed for this movement is respected). Once the retrograde phase is complete (coloured liquid in "Zone I"), ensure that the crown remains in the time setting position C. Your watch is now ready to be stopped for an extended period.
The capillary 3 is then filled with transparent liquid (it is possible to still see some coloured liquid in "Zone I").
Produced and tested to very stringent criteria, the constituent components of your HYT watch together form an exceptionally water resistant unit (to a depth of 50 metres). To ensure these qualities are preserved, we recommend that you replace the gaskets every 3 years. Temperature variations, moisture, perspiration or repeated impacts may adversely affect its water resistance over the years.
With its water resistant case, your HYT watch is fully washable. It should be cleaned regularly in lukewarm, soapy water, rinsed and then carefully dried with a soft cloth. After exposure to sea water, rinse your HYT watch in fresh water.

GLOSSARY p.6

QUICK GUIDE p.7

To create a liquid time indicator that is compact, wearable and multi-purpose, HYT has developed a completely new high-tech concept, using two flexible bellows at each end of a capillary tube. The system is sealed in accordance with the most stringent standards used in the aerospace industry, with each bellow containing immiscible liquids. The fluidic module represents this complete system.
1. Meniscus:
The two liquids are separated by the positive and negative polarities of their respective molecules that keep them apart like magnetic repulsion. The meniscus marks the surface separating the liquids in the tube, indicating the time.
2. Bellows:
The bellows are the two reservoirs located at 6 o'clock. They are made of a highly resistant, flexible electro-deposited alloy four times finer than a human hair. The movement compresses the left-hand bellows which is emptied of its coloured liquid. The other bellows then fills, and vice versa, moving the liquid within the capillary, and with it the meniscus which indicates the time.
3. Capillary:
This tube, made from the best quality glass as used in the medical industry, is circular in shape and contains two immiscible liquids. A nanometric surface treatment is applied to this inside of the capillary, which enables the two liquids to move smoothly without adhering to the glass.
4. Retrograde:
When the coloured liquid gets to 6 o'clock (Zone II), it switches to retrograde mode, flowing back to its original position (Zone I).
QUICK GUIDE

- Time display
- Minute hand
- Seconds display
Crown settings
Pos A.: crown screwed down
Pos B.: winding (unscrewed)
Pos C.: time setting
(pulled out)
- Power reserve indicator (65 hours)
- Dynamo push-piece activating the light system (Available on limited models)
SCREW-DOWN CROWN Pos A.

INTRODUCTION
This type of crown provides excellent protection to ensure the case is watertight.
The crown must be unscrewed before changing the watch settings and screwed back down afterwards.
HOW TO USE
- Unscrew the crown before changing the watch settings
• Afterwards, push the crown back in against the case and screw it back down - Check from time to time that the crown is fully screwed down.
WINDING
Pos B.

INTRODUCTION
This function ensures that the power required to drive your watch is stored by the movement.
HOW TO USE
- Unscrew the crown before changing the watch settings "A"
- Wind the watch by turning the crown clockwise "B"
- Afterwards, push the crown back in against the case and screw it back down "A".
SETTING THE TIME
Pos C.

INTRODUCTION
This function allows the time shown on your watch to be set using the crown.
IMPORTANT
- Moving the microfluids within the capillary 3 should be approached with as much caution as setting a perpetual calendar or a minute repeater
• We highly recommend that the fluid is only moved 10 minutes with each movement of the crown - This should mean that moving the fluid a full hour takes no more than 12 seconds.
HOW TO USE
- Unscrew the crown and pull it out to position "C"
- Then turn the crown in either direction until the coloured liquid (hour display) and the minute hand is at the time required
- Push the crown in completely against the case
- Do not forget to screw in the crown completely to ensure its water resistance.
RETROGRADE
- The automatic return of the coloured liquid (retrograde) 4 is allowed by the pressure of the two bellows 2 . The speed is higher when the retrograde 4 starts in "Zone II" and is minimal when the liquid approaches its starting point in "Zone I".

SETTING THE TIME COUNTER CLOCKWISE
It is completely possible to set your watch counter clockwise.
Warning: counter clockwise movement of the crown must be stopped immediately if the coloured liquid is no longer visible or if it is stored in "Zone I".

DISPLAY TIME EXAMPLES
1) 6:30 am

2) 10:35 am

3) 5:50 pm

POWER RESERVE
INDICATOR


Empty Full

(65 hours of power reserve)
INTRODUCTION
This power reserve indicator function provides a real-time display of your watch's power, thereby indicating how long it will continue to run without the spring being rewound.
HOW TO USE
- The display uses a small hand on the dial which travels in an arc from the "full" indicator to the "empty" indicator (red indicator)
- To ensure optimal operation of the watch, we recommend that you check it is fully wound (see WINDING).
DYNAMO PUSH-PIECE ACTIVATING THE LIGHT SYSTEM


INTRODUCTION
This function activates the light system for your watch.
HOW TO USE
- Wind the dynamo by turning the crown clockwise "A"
- Press the push-piece on the crown to activate the light system by converting mechanical power into light "B".
If the generator has been fully wound, the light system can be activated several times by pressing the push-piece, or it can be activated continuously by pressing and holding the push-piece until the generator is drained.