Product Type Motion Detector (Occupancy/Vacancy Sensor)
Brand Leviton
Model OSC04-IAW
Detection Technology Passive Infrared (PIR)
Coverage Angle 360 degrees
Maximum Coverage Area Up to 900 sq. ft. at 8 ft. mounting height
Mounting Type Ceiling mount
Dimensions (Diameter x Height) 4.2 in x 1.5 in
Weight 2.4 oz
Input Voltage 120-277 VAC, 50/60 Hz
Load Rating 800W incandescent, 1/2 HP motor, 1000VA LED/CFL
Time Delay Settings 30 seconds, 5 minutes, 15 minutes, 30 minutes
Ambient Light Sensor Adjustable (daylight harvesting option)
Manual Override Yes (manual-on/auto-off or auto-on/auto-off)
Wire Connections Pigtail leads (Black, White, Red, Green)
Operating Temperature 32°F to 131°F (0°C to 55°C)
Certifications UL Listed, Title 24 compliant
Warranty 5 years
Cleaning Instructions Wipe with a dry cloth; do not use liquid cleaners
Safety Disconnect power before installation; use approved wiring methods
Repairability No user-serviceable parts; replace unit if defective

Frequently Asked Questions - OSC04-IAW Leviton

What is the coverage area of the Leviton OSC04-IAW motion detector?
The sensor covers up to 900 sq. ft. with a 360-degree field of view when mounted at 8 ft. height.
How do I adjust the time delay?
Use the dial on the sensor to select among preset delays: 30 seconds, 5, 15, or 30 minutes.
Can I use this sensor with LED lights?
Yes, it is rated for up to 1000 VA of LED/CFL load.
Does the OSC04-IAW have a daylight sensor?
Yes, it includes an adjustable ambient light sensor for daylight harvesting.
What is the difference between occupancy and vacancy mode?
In occupancy mode, lights turn on automatically when motion is detected. In vacancy mode, lights must be turned on manually and turn off automatically when no motion is detected.
How do I install the motion detector?
Connect the black (line), white (neutral), red (load), and green (ground) wires using wire nuts, then mount to the ceiling. Ensure power is off.
What is the operating voltage?
It operates on 120-277 VAC, 50/60 Hz.
Can I use it with a dimmer?
This sensor is not designed for use with dimmers; use a compatible switch for dimming functions.
Why does the light stay on or not turn off?
Check the time delay setting, ensure the sensor is not blocked, and verify wiring connections. If the issue persists, the sensor may need replacement.
How do I clean the sensor?
Wipe with a dry, soft cloth. Avoid liquids or abrasive cleaners to prevent damage.

User questions about OSC04-IAW Leviton

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Motion detector in PDF format for free! Find your manual OSC04-IAW - Leviton and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. OSC04-IAW by Leviton.

USER MANUAL OSC04-IAW Leviton

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Leviton

Model : OSC04-IAW

Category : Motion detector