Product TypeCarbon Monoxide Alarm with Digital Display
BrandKidde
ModelKN-COP-DP-B
Dimensions (H x W x D)4.7 x 3.2 x 1.5 inches
Weight0.5 lb (227 g)
Power Source120V AC hardwired with 9V battery backup
Detection TypeElectrochemical CO sensor
DisplayDigital LED display showing CO concentration (ppm)
Alarm LevelsAudible alarm at 85 dB at 10 feet
FeaturesTest/Hush button, peak level memory, end-of-life warning
InstallationWall mount or plug-in (adapter included)
Operating Temperature40°F to 100°F (4°C to 38°C)
Humidity Range5% to 95% relative humidity (non-condensing)
Battery Backup9V alkaline (lasts up to 1 year)
Sensor Life10 years from date of manufacture
End-of-LifeUnit chirps and displays 'END' after 10 years
ComplianceUL 2034, CSA 6.19-01
Warranty5-year limited
MaintenanceVacuum monthly; test weekly; replace unit every 10 years
Spare PartsBattery (9V alkaline); no user-replaceable sensors

Frequently Asked Questions - KN-COP-DP-B KIDDE

Where should I install the Kidde KN-COP-DP-B?
Install the alarm in a location where it can detect CO from all sleeping areas. Avoid kitchens, garages, and areas with high humidity. Mount at least 5 feet from the floor and 10 feet from appliances.
What does the digital display show?
The display shows the current carbon monoxide concentration in parts per million (ppm). It also shows peak levels recorded and error codes for troubleshooting.
Why is my alarm chirping intermittently?
Intermittent chirps can indicate low battery, end-of-life (after 10 years), or a sensor fault. Check the display for an error code (e.g., 'Err' or 'End'). Replace the battery if needed.
How often should I test the alarm?
Test the alarm weekly by pressing and holding the Test/Hush button until the alarm sounds. The test checks the sensor, electronics, and horn.
What should I do if the alarm sounds continuously?
If the alarm sounds (4 beeps, pause, repeat), treat it as a real emergency. Evacuate immediately, call 911, and do not re-enter until responders clear the area.
Can I use this alarm in a recreational vehicle (RV)?
The KN-COP-DP-B is designed for residential use and may not be suitable for RVs due to voltage variations and environmental factors. Consult the manual for specific guidelines.
How long does the battery backup last?
A fresh 9V alkaline battery provides backup power for about 1 year under normal conditions. Replace the battery annually or when the low-battery chirp occurs.
What is the end-of-life warning?
After 10 years from the date of manufacture, the alarm will chirp and display 'END'. You must replace the entire unit, as the sensor is not replaceable.
How do I clean and maintain the alarm?
Use a vacuum cleaner with a soft brush attachment to gently remove dust from the vents. Wipe the exterior with a damp cloth. Do not use cleaners or solvents.
What does 'Err' on the display mean?
'Err' indicates a sensor or internal fault. Try cleaning the unit and pressing the test button. If the error persists, replace the alarm immediately.

User questions about KN-COP-DP-B KIDDE

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Gas detector in PDF format for free! Find your manual KN-COP-DP-B - KIDDE and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. KN-COP-DP-B by KIDDE.

USER MANUAL KN-COP-DP-B KIDDE

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : KIDDE

Model : KN-COP-DP-B

Category : Gas detector