Product Type Commercial Refrigerated Display Case (Merchandiser)
Brand Structural Concepts
Model Reveal NE4827HSV
Width 48 inches
Depth 27 inches
Height Approximately 77 inches (6.4 ft)
Weight Approximately 280 lbs
Power Supply 115 V, 60 Hz, 8.5 A
Plug Type NEMA 5-15P, grounded
Refrigerant R290 (hydrocarbon, environmentally friendly)
Temperature Range 33°F to 41°F (0.5°C to 5°C)
Doors Two hinged glass doors (self-closing)
Shelving Adjustable wire shelves (4-6 included)
Lighting Interior LED lighting, energy-efficient
Temperature Control Digital thermostat with external display
Defrost System Automatic electric defrost (cycle timer)
Leveling Four adjustable leveling legs
Cleaning & Maintenance Daily interior wipe-down; monthly condenser coil cleaning
Safety Features Grounded plug, tip-over restraint brackets (optional)
Energy Consumption Approximately 8 kWh/day (Energy Star certified)
Certifications NSF/ANSI 7, UL, cUL
Spare Parts Availability Shelves, door gaskets, thermostats, LEDs, casters (optional)
Warranty 3 years parts and labor (limited)

Frequently Asked Questions - Reveal NE4827HSV Structural Concepts

How do I adjust the temperature on my Structural Concepts Reveal NE4827HSV?
The temperature is adjusted via the digital controller located on the top front of the unit. Press and hold the SET button until the display flashes, then use the UP/DOWN arrows to set the desired temperature between 33°F and 41°F. Press SET again to confirm. Refer to the manual for detailed programming options.
What type of refrigerant does the NE4827HSV use?
This unit uses R290 refrigerant (propane), which is a natural hydrocarbon with zero ODP and low GWP. It is environmentally friendly but flammable. Ensure proper ventilation and avoid damaging the refrigerant circuit.
Why is my unit not cooling properly?
Common causes include: dirty condenser coils (clean with a brush/ vacuum), blocked airflow inside (overstocking), door gasket leaks (check for gaps), or incorrect temperature setting. If the problem persists, the thermistor or compressor may be faulty—contact a qualified technician.
How often should I clean the condenser coils?
Clean the coils every month for optimal performance. Use a soft brush or vacuum with a crevice tool. For heavy dust, compressed air can be used. Never use water or liquid cleaners on the coils.
Can I install this unit outdoors or in direct sunlight?
No. The Reveal NE4827HSV is designed for indoor use only in a climate-controlled environment. Direct sunlight or temperatures above 100°F (38°C) can cause overheating and reduce efficiency. Ambient temperature should be between 60°F and 80°F.
How do I defrost the unit?
The unit features an automatic electric defrost system. The controller initiates a defrost cycle every 6 hours (adjustable). During defrost, the evaporator coils warm up to melt frost. Water drains into a tray that evaporates. Manual defrost is not needed.
What are the dimensions and weight of the NE4827HSV?
The unit is approximately 48 inches wide, 27 inches deep, and 77 inches high. Weight is around 280 lbs. Ensure your floor can support the load and that there is clearance for ventilation.
How do I change the interior LED lights?
The LED lights are integrated and should last for years. If replacement is needed, contact Structural Concepts parts. To access, unplug the unit, remove the light cover (usually held by screws or clips), and disconnect the wiring harness. Use only genuine replacement LEDs rated for refrigerated environments.
Is this unit Energy Star certified?
Yes, the Reveal NE4827HSV is Energy Star certified. It typically consumes about 8 kWh per day, though actual usage varies with ambient temperature and loading. It meets strict efficiency guidelines set by the EPA.
What spare parts are available for this model?
Common spare parts include: replacement shelves, door gaskets, digital thermostats, LED light strips, leveling legs, and casters. Contact your dealer or Structural Concepts directly with the model and serial number for ordering.

User questions about Reveal NE4827HSV Structural Concepts

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Heated display case in PDF format for free! Find your manual Reveal NE4827HSV - Structural Concepts and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. Reveal NE4827HSV by Structural Concepts.

USER MANUAL Reveal NE4827HSV Structural Concepts

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Structural Concepts

Model : Reveal NE4827HSV

Category : Heated display case