| Product Type | Refrigerated Merchandiser |
| Brand | Structural Concepts |
| Model | Reveal NE3635HSV |
| Width | 36 inches |
| Depth | 30 inches |
| Height | 72 inches |
| Weight | 300 lbs |
| Power Supply | 115V / 60Hz / 15A |
| Temperature Range | 33°F to 38°F (0.5°C to 3.3°C) |
| Capacity | 35 cubic feet |
| Lighting | LED interior lighting |
| Shelving | Adjustable wire shelves (5 included) |
| Door Type | Self-closing glass doors with adjustable hinges |
| Refrigerant | R-290 (propane) |
| Compressor Location | Top-mounted (condensing unit) |
| Condenser Cleaning | Quarterly recommended, use vacuum or soft brush |
| Defrost Type | Automatic electric defrost |
| Interior Material | Stainless steel floor and back, aluminum sides |
| Exterior Finish | White or black textured steel |
| Gaskets | Replaceable magnetic door gaskets |
| Castors | 4 heavy-duty castors (2 locking) |
| Temperature Control | Digital thermostat with lockable guard |
| Certifications | UL, ETL, NSF-7 compliant |
| Warranty | 3-year parts and labor, 5-year compressor |
Frequently Asked Questions - Reveal NE3635HSV Structural Concepts
What is the ideal ambient temperature for the Reveal NE3635HSV?
The unit is designed for indoor use with ambient temperatures between 68°F and 78°F (20°C to 26°C). Operating outside this range may affect performance.
How often should I clean the condenser coils?
Condenser coils should be cleaned at least every three months using a soft brush or vacuum. More frequent cleaning may be needed in dusty environments.
Can I adjust the temperature setpoint?
Yes, the digital thermostat allows adjustment. Press the SET button, use the arrow keys to set between 33°F and 38°F, and press SET again to confirm. The control is protected by a lockable guard.
What should I do if the unit is not cooling?
Check that the power cord is plugged in and the circuit breaker is not tripped. Verify the condenser coils are clean. If the compressor runs but no cooling, the refrigerant charge may be low. Contact a qualified technician.
How do I adjust the door hinges?
The self-closing doors have adjustable hinges. Use a wrench to turn the adjustment screw on the hinge, typically a hexagonal bolt. Check the manual for the correct direction to increase or decrease closing force.
What type of refrigerant does this model use?
The Reveal NE3635HSV uses R-290 (propane) refrigerant, which is environmentally friendly but flammable. Service must be performed by certified professionals.
Can I replace the door gaskets myself?
Yes, door gaskets are designed to be user-replaceable. Remove the old gasket from the channel, press the new gasket into place, and trim any excess. Order genuine Structural Concepts gaskets for proper fit.
What is the recommended clearance for ventilation?
Leave at least 6 inches of clearance on the sides and top for proper airflow. The condenser is top-mounted, so ensure no obstructions above the unit.
How do I level the unit?
Use the adjustable leveling legs (castors can be locked or removed). Place a spirit level on the interior floor and adjust each leg until the unit is level side-to-side and front-to-back.
What does the alarm code 'E1' mean?
Error code 'E1' indicates a sensor failure. The unit will continue to cool but in a default mode. Please contact Structural Concepts service for a replacement sensor.
User questions about Reveal NE3635HSV Structural Concepts
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.
Download the instructions for your Heated display case in PDF format for free! Find your manual Reveal NE3635HSV - Structural Concepts and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. Reveal NE3635HSV by Structural Concepts.