ADAM-5017P - Industrial electronic module Advantech - Free user manual and instructions
Find the device manual for free ADAM-5017P Advantech in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Product Type | Analog Input Module |
| Input Channels | 16 differential |
| Resolution | 16-bit |
| Input Ranges (Voltage) | ±10 V, ±5 V, ±2.5 V, ±1.25 V |
| Input Ranges (Current) | ±20 mA (with external 125 Ω resistor) |
| Sampling Rate | 100 Hz (total) |
| Communication Interface | RS-485 |
| Protocol | Modbus/RTU |
| Power Supply | 10–30 VDC |
| Power Consumption | 1.2 W typical |
| Dimensions (W x H x D) | 70 mm x 112 mm x 112 mm |
| Weight | 150 g |
| Mounting | DIN-rail |
| Operating Temperature | -10 to 70 °C |
| Isolation | 3000 VDC |
| Maintenance | Clean with dry cloth; avoid liquids |
| Safety | Use specified power supply; follow wiring diagram |
| Spare Parts / Repairability | Not user-serviceable; contact Advantech support |
| General Information | Industrial automation, data acquisition, rugged design |
| Manual Languages | English (PDF available) |
Frequently Asked Questions - ADAM-5017P Advantech
How do I wire the ADAM-5017P for voltage input?
Connect the positive signal to the Vin+ terminal and ground to GND. Ensure the module is set to the correct input range via DIP switches.
Can I measure current with this module?
Yes, by placing a 125 Ω resistor across the input terminals, you can measure ±20 mA current loops.
What is the default communication settings?
Default: 9600 baud, 8 data bits, no parity, 1 stop bit, Modbus RTU slave ID 1.
How do I change the Modbus address?
Use the DIP switches on the module to set the address (1-255). Refer to the manual for switch positions.
What power supply is required?
A 10-30 VDC power supply with at least 1.2 W capacity. Connect to the +Vs and GND terminals.
Is the module isolated?
Yes, it provides 3000 VDC isolation between input channels and the communication/power circuits.
Can I mount it on a DIN rail?
Yes, the module comes with a DIN-rail clip for standard 35 mm rails.
How to reset to factory defaults?
Power off, set all DIP switches to OFF, then power on. The module will revert to default settings.
What is the update rate?
The module samples all channels at a total rate of 100 Hz (6.25 Hz per channel if all enabled).
Where can I find the driver and software?
Download the Advantech AdamApax.NET Utility or Modbus configuration tools from the official website.
User questions about ADAM-5017P Advantech
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.