VACON 20 - Uncategorized DANFOSS - Free user manual and instructions
Find the device manual for free VACON 20 DANFOSS in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Type of product | Variable Frequency Drive (VFD) |
| Model | VACON 20 |
| Brand | Danfoss |
| Power range | 0.75 kW to 2.2 kW |
| Input voltage | 3-phase 380-480 V AC, 50/60 Hz |
| Output frequency | 0-500 Hz |
| Dimensions (H x W x D) | 200 mm x 130 mm x 150 mm |
| Weight | 1.5 kg |
| Enclosure rating | IP20 |
| Display | LED with 4-digit numeric display |
| Keypad | Integrated keypad with start/stop and potentiometer |
| Communication interfaces | Modbus RTU (RS-485) |
| Control methods | V/f, sensorless vector, torque control |
| Protection functions | Overcurrent, overvoltage, undervoltage, overtemperature, short circuit |
| Mounting type | Wall mount, book style |
| Operating temperature | -10°C to +50°C |
| Storage temperature | -40°C to +70°C |
| Humidity | Less than 95% (non-condensing) |
| Maintenance and cleaning | Clean with dry cloth; check fan and air vents regularly |
| Safety features | Safe torque off (STO) as per EN 61800-5-2 |
| Spare parts and repairability | Spare parts available from Danfoss; repair by authorized service centers |
Frequently Asked Questions - VACON 20 DANFOSS
How do I reset the VACON 20 to factory defaults?
Go to parameter P9.8.1 (Restore Defaults) and set to 1. Then press Enter to confirm.
What is the maximum cable length for motor connections?
The maximum recommended motor cable length is 50 meters for unshielded cable and 100 meters for shielded cable.
Can the VACON 20 run single-phase motors?
No, the VACON 20 is designed for three-phase motors only. It requires a three-phase input and output.
How do I change the frequency reference source?
Set parameter P1.1.1 (Reference Source) to choose between Keypad, Analog Input, Modbus, or other options.
What does error code 'F12' mean?
Error code F12 indicates overcurrent. Check motor connections, load, and acceleration/deceleration times.
How do I enable the built-in PID controller?
Set parameter P2.1.1 (PID Enable) to 1. Then configure PID setpoint, gain, and feedback source in parameters P2.2 to P2.4.
Is the VACON 20 compatible with EtherNet/IP?
The standard VACON 20 does not support EtherNet/IP. Only Modbus RTU is built-in. For other fieldbuses, use an optional option card.
How often should I replace the cooling fan?
The cooling fan should be replaced every 3-5 years or after 50,000 operating hours, whichever comes first.
Can I use the VACON 20 in a regenerative braking application?
Yes, but you need an optional braking resistor connected to terminals R- and R+. Configure braking parameters in P3.5.
How do I set the motor nominal parameters?
Enter motor nameplate data in parameters P1.2.1 (Motor Voltage), P1.2.2 (Motor Current), P1.2.3 (Motor Speed), and P1.2.4 (Motor Frequency).