Product Type Split System Air Conditioner
Model WH-UDZ12KE5
Brand Panasonic
Cooling Capacity (BTU/h) 12,000
Cooling Capacity (kW) 3.5
Power Supply 220-240V, 50Hz
Refrigerant R32
Indoor Unit Dimensions (WxHxD) 798 x 295 x 232 mm
Outdoor Unit Dimensions (WxHxD) 780 x 542 x 290 mm
Indoor Unit Weight 10.0 kg
Outdoor Unit Weight 28.0 kg
Energy Efficiency Ratio (EER) 3.2
Seasonal Energy Efficiency Ratio (SEER) 6.1
Noise Level Indoor (dB) 26 - 39
Noise Level Outdoor (dB) 48
Air Flow Volume (m³/h) 600
Inverter Technology Yes
Timer Function 24-hour on/off timer
Remote Control Included
Filter Type Washable, antibacterial
Pipe Connection Size (Liquid/Gas) 1/4 inch / 3/8 inch
Maximum Pipe Length 15 m
Operating Temperature Range (Cooling) -10°C to 46°C

Frequently Asked Questions - WH-UDZ12KE5 PANASONIC

How often should I clean the air filter?
The air filter should be cleaned every 2 weeks under normal usage. A clogged filter reduces efficiency and may cause freezing. Use a vacuum or wash with water and dry thoroughly before reinstalling.
What refrigerant does this model use?
The Panasonic WH-UDZ12KE5 uses R32 refrigerant, which has lower global warming potential compared to R410A. Ensure proper handling by a certified technician.
Can the air conditioner be used for heating?
No, this model is a cooling-only split air conditioner. It does not have a heat pump function. For heating, consider a reverse-cycle model.
What is the recommended room size for this unit?
The 12,000 BTU/h capacity is suitable for rooms up to 40-50 m², depending on insulation, sun exposure, and ceiling height.
How do I reset the unit after a power failure?
Simply turn the unit off and on using the remote control or the main power switch. The timer settings may need to be reprogrammed. If an error code appears, consult the manual.
What does error code H9 mean?
Error code H9 indicates a power supply voltage drop or failure. Check the voltage at the outlet and ensure the circuit breaker is not tripped. Reset the unit after restoring power.
How do I clean the outdoor unit?
Turn off the power before cleaning. Use a soft brush or vacuum to remove dust and debris from the fins and fan. Do not use water pressure directly on electrical components. Schedule professional maintenance annually.
Can I install the outdoor unit in a partially enclosed space?
The outdoor unit requires adequate airflow. Do not install in a confined space unless ventilation openings are provided. Minimum clearance: 30 cm on sides, 50 cm above, and 100 cm in front.
What is the energy efficiency rating?
The unit has an EER of 3.2 and SEER of 6.1, which corresponds to a high energy efficiency class (approx. A+/A++ depending on region). Actual consumption depends on usage.
How to use the timer function?
Press the TIMER button on the remote to set the on or off timer. Use the +/- buttons to set the hour. Confirm with SET. The unit will start/stop automatically at the programmed time.

User questions about WH-UDZ12KE5 PANASONIC

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Air Conditioning in PDF format for free! Find your manual WH-UDZ12KE5 - PANASONIC and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. WH-UDZ12KE5 by PANASONIC.

USER MANUAL WH-UDZ12KE5 PANASONIC

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : PANASONIC

Model : WH-UDZ12KE5

Category : Air Conditioning