Product Type Air-cooled water chiller
Model EWAT155B-SSB2
Brand Daikin
Cooling Capacity 155 kW
Power Supply 400 V / 3-phase / 50 Hz
Refrigerant R410A
Dimensions (L x W x H) 2500 x 1000 x 1800 mm
Weight 2000 kg
Compressor Type Scroll
Condenser Type Air-cooled fin-and-tube
Evaporator Type Brazed plate heat exchanger
Sound Pressure Level 75 dB(A) at 1 m
Water Flow Rate 26.6 m³/h
Water Pressure Drop 40 kPa
Ambient Operating Range -10°C to 45°C
Safety Features High/low pressure switch, overload protection, freeze protection
Maintenance Clean condenser coils annually, check refrigerant charge, inspect electrical connections
Spare Parts Filters, fan motors, compressors, pressure switches, control boards
Reparability Modular design; components replaceable by qualified technicians
Warranty 2 years (parts and labor)

Frequently Asked Questions - EWAT155B-SSB2 DAIKIN

What is the correct installation clearance for the unit?
Maintain at least 1.5 m clearance on all sides for proper airflow and service access.
How often should the condenser coils be cleaned?
Clean condenser coils at least twice a year or more frequently in dusty environments to ensure efficient heat exchange.
What type of refrigerant does this chiller use?
The unit uses R410A refrigerant which is a high-pressure HFC blend.
Can the chiller operate in freezing conditions?
Yes, the unit includes freeze protection and can operate down to -10°C ambient temperature, but water loop may require antifreeze.
What should I do if the unit displays a low pressure alarm?
Check for refrigerant leaks, ensure the liquid line valve is open, and verify that the evaporator water flow is adequate.
How do I reset the high pressure cutout switch?
Press the manual reset button on the high pressure switch after identifying and correcting the cause of high pressure.
Is regular water treatment required for the evaporator circuit?
Yes, maintain proper water quality with chemical treatment to prevent scaling and corrosion in the evaporator.
What is the recommended temperature setpoint for chilled water?
Typical setpoint is 7°C (44.6°F) for standard air conditioning applications.
Can the unit be controlled remotely?
Yes, it supports Modbus RTU communication for integration with building management systems.
What safety precautions should be taken during maintenance?
Always disconnect power supply before servicing, use proper PPE, and recover refrigerant properly.

User questions about EWAT155B-SSB2 DAIKIN

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Air Conditioning in PDF format for free! Find your manual EWAT155B-SSB2 - DAIKIN and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. EWAT155B-SSB2 by DAIKIN.

USER MANUAL EWAT155B-SSB2 DAIKIN

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : DAIKIN

Model : EWAT155B-SSB2

Category : Air Conditioning