QUINT4-PS/3AC/24DC/20 - Uncategorized Phoenix Contact - Free user manual and instructions
Find the device manual for free QUINT4-PS/3AC/24DC/20 Phoenix Contact in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Product Type | Power Supply Unit |
| Input Voltage | 3-Phase AC 400-500 V AC |
| Output Voltage | 24 V DC |
| Output Current | 20 A |
| Power Rating | 480 W |
| Dimensions (H x W x D) | 125 x 125 x 130 mm |
| Weight | 1.2 kg |
| Efficiency | > 95% |
| Operating Temperature | -25°C to +70°C |
| Protection Functions | Overload, short-circuit, overvoltage |
| Connection Type | Screw terminals |
| Certifications | CE, UL 508, cUL |
| Maintenance | No maintenance required |
| Parallel Operation | Yes, for redundancy or increased power |
| LED Indicators | Status: OK, overload, error |
| Warranty | 5 years |
Frequently Asked Questions - QUINT4-PS/3AC/24DC/20 Phoenix Contact
What is the input voltage range for the QUINT4-PS/3AC/24DC/20?
The input voltage range is 3-phase AC 400-500 V AC. It can handle a wide range of 3-phase supplies.
Can this power supply be used with single-phase input?
No, the QUINT4-PS/3AC/24DC/20 is designed for 3-phase input only. Using single-phase may cause damage or improper operation.
What is the output current rating?
The output current rating is 20 A at 24 V DC, providing a total power of 480 W.
Does it have overvoltage protection?
Yes, it includes overvoltage protection to safeguard connected devices from voltage spikes.
How do I connect the input wires?
Connect the three phases to terminals labeled L1, L2, L3, and the ground to PE. Use screw terminals with appropriate torque.
What is the efficiency of this power supply?
Efficiency is typically greater than 95%, reducing energy loss and heat generation.
Is it suitable for harsh industrial environments?
Yes, it's designed for industrial use with wide temperature range and robust construction.
What is the operating temperature range?
The operating temperature range is -25°C to +70°C, suitable for demanding conditions.
Can multiple units be paralleled for higher current?
Yes, parallel operation is supported for increased power or redundancy. Follow the manual for proper configuration.
What certifications does the QUINT4-PS/3AC/24DC/20 have?
It carries CE, UL 508, and cUL certifications, ensuring compliance with international standards.