MWH-130ECNCR - Boiler MIDEA - Free user manual and instructions
Find the device manual for free MWH-130ECNCR MIDEA in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Product Type | Wall-mounted gas boiler |
| Brand | Midea |
| Model | MWH-130ECNCR |
| Dimensions (H x W x D) | 700 x 400 x 300 mm |
| Weight | 28 kg |
| Fuel | Natural gas / Propane (convertible) |
| Heating capacity | 24 kW |
| DHW flow rate | 10 L/min (ΔT 30°C) |
| Expansion vessel capacity | 8 L |
| Heating temperature range | 30 - 80 °C |
| DHW temperature range | 35 - 65 °C |
| Efficiency | Up to 93% (NCV) |
| Main functions | Central heating, domestic hot water production, thermostatic regulation, anti-freeze, automatic bleed |
| Maintenance and cleaning | Cleaning primary circuit filter, bleeding radiators, checking pressure (1-2 bar) |
| Safety | Overheating safety, water shortage safety, anti-freeze safety, gas lockout |
| Spare parts and repairability | Available parts: heat exchanger, circulation pump, expansion vessel, electrodes, thermostat |
| Installation | Flue connection, gas and electrical supply 230V/50Hz |
| Energy class | Class A (according to ErP directive) |
| Warranty | 2 years parts and labor |
Frequently Asked Questions - MWH-130ECNCR MIDEA
How to turn on the Midea MWH-130ECNCR boiler?
Ensure gas and electrical power are connected. Press the ON/OFF button. The green indicator lights up. The boiler goes into standby. To activate heating, adjust the room thermostat.
What to do if the red light comes on?
The red light indicates a fault. Check the error code displayed on the screen. Common codes: E01 (sensor failure), E02 (overheating). Reset the device by turning off the power for 10 seconds. If it persists, contact a professional.
How to drain the boiler for winter?
Turn off gas and electrical power. Close the flow and return valves. Connect a hose to the drain valve and open it. For extended shutdown, completely drain the heating circuit.
What water pressure is recommended?
The pressure should be maintained between 1 and 2 bars (cold). If it drops below 0.5 bar, refill via the filling tap to 1.5 bar. If it exceeds 2.5 bars, bleed the radiators.
How to bleed the radiators?
Turn off the heating. Open the radiator bleed valve with a key until water comes out or no more air is released. Close it. Check the boiler pressure and adjust if necessary.
The boiler is making an abnormal noise, why?
Noises can come from air in the circuit (bleed), insufficient pressure (refill), or a build-up of limescale (descaling). If the noise persists, check the circulation pump or heat exchanger.
What annual maintenance is required?
Maintenance by a professional is mandatory (chimney sweep, burner check, heat exchanger cleaning, safety check). You can clean the primary circuit filter yourself.
How to adjust the hot water temperature?
Use the dial or buttons on the control panel. The domestic hot water temperature can be set between 35°C (summer) and 65°C (winter). For heating, adjust the room thermostat.
What to do in case of a water leak?
Immediately turn off the water supply and electrical power. Identify the source (seal, expansion vessel, heat exchanger). Contact a heating engineer. Do not attempt repairs without qualifications.
Where to find spare parts?
Spare parts (heat exchanger, circulation pump, expansion vessel, electrodes) are available from Midea authorized dealers or online. Use the model number MWH-130ECNCR to identify the part.