OLS3000ECXL - Inverter CyberPower - Free user manual and instructions
Find the device manual for free OLS3000ECXL CyberPower in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Product Type | Uninterruptible Power Supply (UPS) |
| Model | OLS3000ECXL |
| Brand | CyberPower |
| Capacity (VA / Watts) | 3000 VA / 2700 W |
| Topology | Online Double Conversion |
| Input Voltage Range | 160–275 VAC (adjustable) |
| Output Voltage | 230 VAC ± 2% (on battery) |
| Output Frequency | 50/60 Hz ± 0.1% (auto sensing) |
| Waveform Type | Pure Sine Wave |
| Number of Outlets | 8 (IEC C13) + 1 (IEC C19) |
| Battery Type | Sealed Lead-Acid (maintenance-free) |
| Battery Size | 12V / 9 Ah (x6 internal) |
| Typical Backup Time (half load) | ~15 minutes |
| Recharge Time | 4-6 hours to 90% |
| Dimensions (H x W x D) | 440 x 86 x 630 mm (rackmount 2U) |
| Weight | 45 kg (with batteries) |
| Operating Temperature | 0°C to 40°C |
| Relative Humidity | 0% to 95% (non-condensing) |
| Management Interface | RS-232, USB, and optional SNMP/Network card |
| Safety Certifications | CE, IEC 62040, EN 50091 |
| Warranty | 2 years (battery 1 year) |
Frequently Asked Questions - OLS3000ECXL CyberPower
What is the capacity of the CyberPower OLS3000ECXL UPS?
The OLS3000ECXL has a capacity of 3000 VA / 2700 W, suitable for server rooms and network equipment.
How long does the battery last on the OLS3000ECXL?
Battery runtime depends on load. At half load (1350W), expect approximately 15 minutes. Full load runtime is around 5-7 minutes.
Can I replace the batteries in the OLS3000ECXL?
Yes, batteries are field-replaceable hot-swappable. Use CyberPower RB1290 or equivalent 12V 9Ah batteries. Ensure the UPS is in bypass mode during replacement.
What type of output waveform does this UPS provide?
It provides a pure sine wave output, ensuring compatibility with sensitive electronics and active PFC power supplies.
Is the OLS3000ECXL rackmountable?
Yes, it fits a standard 19-inch rack with 2U height. Rackmount rails are included or optional depending on package.
How do I connect the UPS to my network for monitoring?
Use the included USB or RS-232 cable, or install an optional SNMP/Network Management Card (e.g., RCCARD) for remote monitoring via PowerPanel software.
What is the input voltage range of the OLS3000ECXL?
The input voltage range is 160–275 VAC. It can operate at lower voltages with reduced performance. Adjustable via software.
Can I use the UPS with a generator?
Yes, but ensure the generator provides a stable sine wave output. The UPS may switch to battery if voltage or frequency fluctuates too much.
What maintenance does the OLS3000ECXL require?
Periodic battery check (every 6 months) and cleaning of air filters. Keep vents unobstructed. Replace batteries every 3-5 years.
Does the OLS3000ECXL have surge protection for data lines?
Yes, it includes RJ11/RJ45 surge protection for telephone and network lines, protecting against power surges.