Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Sound Level Meter (SLM)
Brand PCE Instruments
Model SLM 10
Measurement Range 30 dB to 130 dB (A and C weighting)
Frequency Weighting A and C (selectable)
Time Weighting Fast (125 ms) and Slow (1 s)
Accuracy ±1.5 dB (at reference conditions)
Resolution 0.1 dB
Display LCD with backlight, 4-digit
Data Hold Yes (MAX/MIN hold)
Auto Power Off Yes (adjustable or disable)
Calibration External calibrator recommended (94 dB at 1 kHz)
Power Supply 9V battery (6F22 or equivalent) or optional AC adapter
Battery Life Approximately 50 hours (continuous use)
Dimensions 230 x 70 x 30 mm
Weight 200 g (including battery)
Operating Temperature 0°C to 40°C (32°F to 104°F)
Humidity Range 10% to 90% RH (non-condensing)
Accessories Included Windscreen, carrying case, user manual, 9V battery
Standards Compliance IEC 61672-1 Class 2 (equivalent)
Maintenance Clean with dry cloth; store in dry environment; replace battery when low
Spare Parts & Repairability Contact PCE Instruments or authorized service centers for repairs; no user-serviceable parts
Safety Use only as intended; avoid exposure to rain or excessive dust; do not disassemble
General Information Compact and lightweight design for portable noise measurement; suitable for industrial, educational, and environmental applications

Frequently Asked Questions - SLM 10 PCE Instruments

How do I calibrate the PCE Instruments SLM 10 sound level meter?
To calibrate, use an external sound calibrator (94 dB at 1 kHz). Insert the microphone into the calibrator, turn the calibrator on, and adjust the calibration screw on the meter (if available) until the display reads 94.0 dB. For best accuracy, calibrate before each use.
What is the difference between A-weighting and C-weighting?
A-weighting filters low frequencies to approximate human hearing sensitivity, ideal for environmental noise. C-weighting has a flatter response, used for peak or impact noise. The SLM 10 allows you to select either weighting depending on your measurement purpose.
How do I change the battery on the SLM 10?
Turn off the meter and slide the battery cover open at the back. Replace the old 9V battery with a new one (type 6F22 or equivalent). Ensure correct polarity. Close the cover securely. Dispose of old batteries properly.
Can I use the SLM 10 outdoors?
Yes, but always attach the supplied windscreen to the microphone to reduce wind noise. Avoid using the meter in heavy rain or extreme humidity. The operating temperature range is 0°C to 40°C.
What do the 'MAX' and 'MIN' hold functions do?
Press the 'MAX' button to capture and hold the highest sound level measured since pressing. Press 'MIN' to hold the lowest level. Press again to return to real-time measurement. Use these functions to monitor peak or trough noise levels.
How do I set the time weighting (Fast/Slow)?
Press the 'F/S' button to toggle between Fast (125 ms response) for fluctuating sounds and Slow (1 s response) for steady noise. The current setting is usually indicated on the display.
What does the 'dB' resolution mean?
The SLM 10 measures sound pressure levels with a resolution of 0.1 dB. This means the display updates in increments of 0.1 dB, providing fine granularity for accurate readings.
Why does my meter show 'ERR' or a dashed display?
An 'ERR' message may indicate an overload (sound level above 130 dB) or an open microphone connection. Check that the microphone is properly attached and not blocked. Reduce the measurement range if applicable (though SLM 10 auto-ranges). If the problem persists, contact support.
Can I connect the SLM 10 to a computer?
The standard SLM 10 does not have a data output port. It is a standalone meter with manual reading. For data logging, consider the PCE-SLM 10 data logging version (if available) or use an external data recorder.
How do I clean and maintain the SLM 10?
Use a soft, dry cloth to clean the exterior. Do not use solvents or water. Store the meter in a dry, dust-free environment when not in use. Remove the battery if storing for extended periods. Calibrate regularly for accurate readings.

User questions about SLM 10 PCE Instruments

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Sound Level Meter in PDF format for free! Find your manual SLM 10 - PCE Instruments and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. SLM 10 by PCE Instruments.

USER MANUAL SLM 10 PCE Instruments

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : PCE Instruments

Model : SLM 10

Category : Sound Level Meter