UTD2062CM - Uncategorized Uni-T - Free user manual and instructions
Find the device manual for free UTD2062CM Uni-T in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Product Type | Digital Storage Oscilloscope |
| Brand | Uni-T |
| Model | UTD2062CM |
| Bandwidth | 60 MHz |
| Channels | 2 |
| Sample Rate | 1 GS/s (Real-time) |
| Record Length | Up to 25 kpts per channel |
| Vertical Sensitivity | 2 mV/div to 10 V/div |
| Timebase Range | 2 ns/div to 50 s/div |
| Display | 7-inch Color LCD, 800 x 480 pixels |
| Input Impedance | 1 MΩ ± 2% in parallel with 15 pF ± 3 pF |
| Maximum Input Voltage | CAT I 300 Vrms, CAT II 100 Vrms |
| Power Supply | AC 100-240 V, 50/60 Hz, 30 VA max |
| Dimensions | 320 x 160 x 130 mm |
| Weight | Approx. 3.5 kg |
| Operating Temperature | 0°C to 40°C |
| Storage Temperature | -20°C to 60°C |
| Interface | USB Host, USB Device, Pass/Fail output |
| Probe Compensation | 1 kHz square wave, 3 Vpp |
| Accessories Included | 2 probes, power cord, USB cable, user manual |
| Maintenance | Clean with a dry cloth; avoid solvents. Calibrate annually. |
| Safety Standards | EN 61010-1, Pollution Degree 2 |
| Spare Parts | Probes, fuses, power cord; contact Uni-T service center |
Frequently Asked Questions - UTD2062CM Uni-T
What is the bandwidth of the Uni-T UTD2062CM?
The Uni-T UTD2062CM has a bandwidth of 60 MHz, suitable for general-purpose electronic measurements.
How many channels does the UTD2062CM have?
It features 2 analog channels, allowing simultaneous measurement of two signals.
What is the maximum real-time sample rate?
The maximum real-time sample rate is 1 GS/s (gigasamples per second) per channel.
Does the UTD2062CM include probes?
Yes, it comes with 2 passive probes (usually 10x attenuation) and a probe compensation output.
What type of display does it have?
It has a 7-inch color LCD with a resolution of 800 x 480 pixels for clear waveform viewing.
What is the input impedance?
The input impedance is 1 MΩ ± 2% in parallel with approximately 15 pF capacitance.
What is the maximum input voltage?
The maximum safe input voltage is CAT I 300 Vrms or CAT II 100 Vrms. Do not exceed these limits.
How do I perform probe compensation?
Connect the probe to the 1 kHz, 3 Vpp square wave output and adjust the probe's compensation capacitor until the waveform is flat.
Can I connect the oscilloscope to a PC?
Yes, via the USB device port. It can be used with Uni-T software for data transfer and remote control.
What maintenance does the oscilloscope require?
Keep the unit clean and dry. It is recommended to have annual calibration to ensure accuracy.
User questions about UTD2062CM Uni-T
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.
Download the instructions for your Uncategorized in PDF format for free! Find your manual UTD2062CM - Uni-T and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. UTD2062CM by Uni-T.