IP175199C - Boiler Rinnai - Free user manual and instructions
Find the device manual for free IP175199C Rinnai in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Brand | Rinnai |
| Model | IP175199C |
| Product type | Gas condensing wall-hung boiler |
| Use | Central heating and domestic hot water production |
| Energy supply | Natural gas (G20) / LPG (G30/G31) |
| Nominal thermal power | 24 kW |
| Efficiency | Up to 98% (GCV) |
| Heating temperature range | 30°C to 80°C |
| DHW temperature range | 35°C to 60°C |
| Maximum operating pressure | 3 bar |
| Dimensions (W x H x D) | 450 x 700 x 300 mm |
| Net weight | 28 kg |
| Gas connection | 3/4" M |
| Heating connection | 3/4" M |
| DHW connection | 1/2" M |
| Flue gas evacuation | Concentric Ø60/100 mm or separate Ø80 mm |
| Energy efficiency class | A |
| Draft type | Sealed combustion |
| Ignition | Electronic |
| Control | Room thermostat or outdoor sensor |
| Protection index | IPX4 |
| Maintenance | Annual cleaning of burner and condenser by a professional |
| Warranty | 2 years parts and labor |
Frequently Asked Questions - IP175199C Rinnai
What is the recommended gas pressure for this model?
The inlet gas pressure must be 20 mbar for natural gas (G20) and 37 mbar for LPG (G30). Check with a manometer.
How do I reset the boiler after a fault?
Press the Reset button for 2 seconds. If the fault persists, check the displayed error code and the manual.
What type of radiator can I use with this boiler?
All radiators compatible with a closed hot water circuit can be used. A flow temperature of 80°C max is recommended.
Is annual maintenance mandatory?
Yes, annual maintenance is mandatory to ensure safety and efficiency. It must be carried out by a qualified professional.
Can the boiler be installed outdoors?
No, this model is designed for indoor installation. Use a shelter if necessary, in a dry and ventilated room.
What does error code E10 mean?
Code E10 indicates a water pressure fault. Check that the heating circuit pressure is between 1 and 1.5 bar.
How do I bleed air from the heating circuit?
Use the manual bleeder valves on each radiator, starting from the lowest and moving up. The boiler must be in shutdown mode.
What diameter of flue gas exhaust duct?
The concentric duct diameter is 60/100 mm. In separate, use 80 mm for air and 80 mm for flue gases.
Is it possible to connect a hot water tank?
Yes, this boiler can supply an indirect DHW tank via a heat exchanger. Consult an installer for the connection.
What is the electrical consumption in standby?
Standby consumption is less than 5 W. During operation, it varies from 80 to 150 W depending on power.
User questions about IP175199C Rinnai
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.
Download the instructions for your Boiler in PDF format for free! Find your manual IP175199C - Rinnai and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. IP175199C by Rinnai.