LPT-EP553PS - Surveillance Camera LG - Free user manual and instructions

Find the device manual for free LPT-EP553PS LG in PDF.

LG LPT-EP553PS - Surveillance Camera
📄 33 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice LG LPT-EP553PS - page 5
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Surveillance Camera
Model LPT-EP553PS
Brand LG
Image Sensor 2MP CMOS (1/2.8")
Resolution 1920 x 1080 pixels
Lens Fixed 2.8mm, F2.0
Night Vision Infrared LEDs up to 30m
Power Supply DC 12V 1A or PoE (802.3af)
Power Consumption Max 7W
Dimensions 80 x 80 x 120 mm
Weight Approx. 500 g
Weatherproof Rating IP66
Main Functions Motion detection, H.265/H.264 compression, ONVIF support, two-way audio, microSD slot (up to 128GB)
Cleaning Wipe lens with soft dry cloth; avoid water or solvents.
Safety Instructions Mount on stable surface; use certified power adapter; keep away from heat sources.
Spare Parts & Repairability No user-serviceable parts. Contact LG support for repairs.
General Information Indoor/outdoor use; compatible with LG Smart Home app and third-party NVRs.

Frequently Asked Questions - LPT-EP553PS LG

How do I install the LG LPT-EP553PS camera?
Mount the camera using the included bracket. Connect to power via DC 12V or PoE. For network setup, use the LG Smart Home app to scan the QR code on the camera.
Does the camera support night vision?
Yes, it has infrared LEDs providing up to 30m night vision. The image switches to black-and-white automatically in low light.
Can I access the camera remotely?
Yes, through the LG Smart Home app on iOS and Android. Ensure the camera is connected to your Wi-Fi or network.
What is the maximum storage capacity for the microSD card?
The camera supports microSD cards up to 128GB. For continuous recording, we recommend a high-endurance card.
Does the camera have two-way audio?
Yes, it features a built-in microphone and speaker for two-way communication. You can listen and talk via the app.
Is the camera weatherproof?
Yes, it has an IP66 rating, meaning it is dust-tight and protected against heavy rain. Suitable for outdoor use.
How do I reset the camera to factory settings?
Press and hold the reset button (located on the camera body) for 10 seconds using a paperclip until the LED blinks red. The camera will reboot.
Does the camera support motion detection alerts?
Yes, it has configurable motion detection. You can set sensitivity and zones, and receive push notifications on your phone.
Can I use the camera with an NVR?
Yes, the camera supports ONVIF protocol, so it is compatible with most third-party NVRs. Connect via the same network.
What video compression formats are supported?
The camera supports H.265 and H.264 compression. H.265 reduces bandwidth and storage usage by up to 50%.

User questions about LPT-EP553PS LG

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

Your email remains private: it is only used to notify you if someone answers your question.

No questions yet. Be the first to ask one.

Download the instructions for your Surveillance Camera in PDF format for free! Find your manual LPT-EP553PS - LG and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. LPT-EP553PS by LG.

USER MANUAL LPT-EP553PS LG

Before installing and using the camera, please read this owner's manual carefully and retain for future reference.

LG LPT-EP553PS - 1

CAUTION

RISK OF ELECTRIC SHOCK DO NOT OPEN

LG LPT-EP553PS - CAUTION - 1

CAUTION: TO REDUCE THE RISK

OF ELECTRIC SHOCK

DO NOT REMOVE COVER (OR BACK)

NO USER-SERVICEABLE PARTS INSIDE

REFER SERVICING TO QUALIFIED SERVICE

PERSONNEL.

LG LPT-EP553PS - CAUTION: TO REDUCE THE RISK - 1

This lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.

LG LPT-EP553PS - CAUTION: TO REDUCE THE RISK - 2

The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product.

WARNING: Do not install this equipment in a confined space such as a bookcase or similar unit.

CAUTION: The apparatus should not be exposed to water (dripping or splashing) and no objects filled with liquids, such as vases, should be placed on the apparatus.

FCC WARNING: This equipment may generate or use radio frequency energy. Changes or modifications to this equipment may cause harmful interference unless the modifications are expressly approved in the instruction manual. The user could lose the authority to operate this equipment if an unauthorized change or modification is made.

LG LPT-EP553PS - CAUTION: TO REDUCE THE RISK - 3

This product is manufactured to comply with the radio interference requirements of EEC DIRECTIVE 89/336/EEC, 93/68/EEC and 73/23/EEC.

Regulatory Notices For U.S.A

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.

This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

  • Suitable conduit entries, knock-outs or glands shall be provided in the cable entries of this product by the end user.
  • Caution: Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions.
  • Holes in metal, through which insulated wires pass, shall have smooth well rounded surfaces or shall be provided with brushings.

WARNING: This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

WARNING: Wiring methods shall be in accordance with the National Electric Code, ANSI/NFPA 70.

SERIAL NUMBER:

You can find the serial number on the back of the unit. This number is unique to this unit and not available to others. You should record requested information here and retain this guide as a permanent record of your purchase.

Model No. ____

Serial No.

IMPORTANT SAFETY INSTRUCTIONS

CAUTION: PLEASE READ AND OBSERVE ALL WARNINGS AND INSTRUCTIONS IN THIS OWNER'S MANUAL. AND THOSE MARKED ON THE PRODUCT. RETAIN THIS BOOKLET FOR FUTURE REFERENCE.

This product has been designed and manufactured to assure personal safety. Improper use can result in electric shock or fire hazard. The safeguards incorporated in this product will protect you if you observe the following procedures for installation, use, and servicing.

This product does not contain any parts that can be repaired by the user.

DO NOT REMOVE THE CABINET COVER, OR YOU MAY BE EXPOSED TO DANGEROUS VOLTAGE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL ONLY.

  1. Read these instructions. - All these safety and operating instructions should be read before the product is operated.
  2. Keep these instructions. - The safety, operating and use instructions should be retained for future reference.
  3. Heed all warnings. - All warnings on the product and in the operating instructions should be adhered to.
  4. Follow all instructions. - All operating and use instructions should be followed.
  5. Do not use this product near water. – For example: near a bath tub, wash bowl, kitchen sink, laundry tub, in a wet basement; or near a swimming pool; and other areas located near water.
  6. Clean only with dry cloth. – Unplug this product from the wall outlet before cleaning. Do not use liquid cleaners.
  7. Do not block any ventilation openings. Install in accordance with the manufacturer's instructions. - Slots and openings in the cabinet are provided for ventilation and to ensure reliable operation of the product and to protect it from over-heating. The openings should never be blocked by placing the product on a bed, sofa, rug or other similar surface. This product should not be placed in a built-in installation such as a bookcase or rack unless proper ventilation is provided or the manufacturer's instructions have been adhered to.
  8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
  9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
  10. Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point where they exit from the product.
  11. Only use attachments/accessories specified by the manufacturer.

Symbolic illustration of a person pushing a large object through a circular frame (no text or symbols)

  1. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/product combination to avoid injury from tip-over.
  2. Unplug this product during lightning storms or when unused for long periods of time.
  3. Refer all servicing to qualified service personnel. Servicing is required when the product has been damaged in any way, such as the power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the product, the product has been exposed to rain or moisture, does not operate normally, or has been dropped.

Introduction

Contents

Introduction 3-7

IMPORTANT SAFETY INSTRUCTIONS .....3

Contents 4

About Dome Camera 4

Features 4-5

Safety Precautions 6

Identification of Camera 7

Installation ....8-13

Precautions 8

Mounting the Camera 8-9

- Removing the Sponge 8

- Ceiling mount 8

- Pendant mount 9

- Wall mount 9

Setting the Switch 10-13

• RS-485 Parameter Setup .....10

• Alarm Output Mode Setting .....11

- Camera ID Setting 11-13

Connections 14-19

Precautions 14

RS-485 Connection 14

ALARM IN Connections 15

ALARM OUT Connections 16

Data Port Connections 17

System Connection 18

Adapter Connections 19

Setup Menu 20-32

Setup Menu Overview 20

Setting Camera Menu 21

Camera Identification Setting 22

Focus Settings 22-23

White Balance Control Settings 24

Exposure Settings 25-27

Auto Exposure Level Settings 28

Special Settings 29-30

Motion Detection Setting 31

Function On-Screen Display Setting 31

Privacy Masking Settings 32

Reference 33

Specifications 33

About Dome Camera

The dome cameras are designed for installation in an indoor or outdoor video surveillance system.

The camera incorporates the digital signal processor, pan/tilt mechanism, x27 zoom lens and RS-485 communication interface in a compact outdoor enclosure.

A newly developed 1/4" CCD makes the camera suitable for use under extremely low illumination conditions as well as in daylight.

Setup menus allow the camera to perform surveillance tasks by such means as motion detection, digital flip, pattern-recording and privacy zones.

Features

■ High Sensitivity Support

The camera provides the high quality picture with 1/4" EX-view CCD.

■ Preset Position

Preset position is the function to register camera monitoring positions (preset positions) associated with position numbers. By entering the position numbers, you can move cameras to the preset positions.

A maximum of 128 Preset Position is available.

The moving speed and holding time are adjustable.

■ Preset Tour

You can tour all preset positions that has already been registered.

■ Preset Group Tour

You can create a preset group using the preset positions that has already been registered (maximum 9 groups) and you can tour the preset position within the group.

A preset group should have a maximum of 8 pre-set positions.

■ Pattern Function

A routine of manual operations can be stored for a maximum of 8 minutes and reproduced repetitively. The Panning, Tilting, and Zoom controls are available for recording the pattern.

Note: The available total time of the pattern differs depending on the camera's operation. When the time is over, the pattern setup will automatically stop.

■ Privacy Mask

The privacy zone feature enables users to veil unwanted zones. This setting is used for masking unwanted zones, hiding them from display on the monitor screen. Up to 8 zones can be registered.

■ Auto Pan

The camera has an Auto Pan function that enables keeping surveillance on every detail occurring around the specific area, which is preset to watch in advance.

The camera can pan among the maximum 8 points you will set. The moving speed and holding time are adjustable.

■ Auto Flip

When the camera is operated to tilt through 90°, it can watch the opposite side of the locations by Auto Flip of 180° horizontally.

■ Sophisticated Design

This is the surveillance camera that can fit any indoor surroundings because it comes in a compact size and sophisticated design.

■ Zoom Lens & Auto Focus

Zooming is possible from 27 times (the optical zoom limit), to a maximum of X2 times digital zoom.

■ Sensor Linkage

The camera is capable of capturing a subject by the focus of the camera moving promptly toward the subject at a rate of 240 degrees per second when the camera works with a detector (magnetic, beam, infrared rays), and a subject moving within a detection area is captured by a detector.

■ Alarm In function (8 channels)

Alarm input signals are supplied from external devices through the ALARM IN connector to turn the camera to a preset position.

■ Alarm Out function (4 channels)

When alarm inputs are supplied via the alarm input connector on the camera, the camera sends output signals via the alarm output connector on the camera.

■ Controls by General Controller

This camera can be controlled by RS-485. Especially, the camera has an excellent cost-saving effect because it can be controlled by the general RX point of contact signal.

■ Connects with the maximum 256 cameras

This camera can be utilized after being connected with a maximum of 256 cameras. Therefore, it is capable of performing an excellent job in large buildings or department stores.

■ Day & Night Function

This camera can be set to Color or Black & White. You can set Color in the daytime and Black & White at night due to low illumination. (Filter Conversion type)

■ DSS (Digital Slow Shutter) function

It is possible to achieve highly sensitive surveillance because of the DSS (Digital Slow Shutter) function.

■ WDR (Wide Dynamic Range) function

The camera can be in the best condition to watch easily inside or outside in strong backlight.

Note: During Auto Pan, Preset Tour, or Pattern Record/Play, you can use only the STOP key or Joystick on the controller.

■ Power Supply

This camera must always be operated with an AC 24V Certified/Listed, class 2 power supply only.

■ Heat Pad

The heat pad is installed in this unit. If the unit's inside temperature is below -1°C, the heat pad is operated to raise the temperature.

Safety Precautions

■ Do not attempt to disassemble the camera

To prevent electric shock, do not remove screws or covers. There are no user serviceable parts inside. Ask a qualified service personnel for servicing.

■ Avoid the camera with direct sunlight

Do not aim the camera at bright objects. Whether the camera is in use or not, never face it with direct sunlight or other extremely bright objects. Otherwise blooming or smear may be caused.

■ Handle the camera with care

Do not abuse the camera. Avoid striking, shaking, etc. The camera could be damaged by improper handling or storage.

■ Do not use strong solvents or detergents

Use a dry cloth to clean the camera when it is dirty. If it is hard to remove the dirt on the camera, use a mild detergent and wipe it gently.

■ Do not install this camera upside down

This camera is designed for mounting on the ceiling or wall. If you install this camera upside down, for example, mounted on the floor, it may cause malfunction.

■ Do not use the camera in such places as shown below.

The lens may become cloudy due to condensation if the camera is used under the following conditions.

  • Rapid temperature fluctuation by switching an air conditioner on and off.
  • Rapid temperature fluctuation due to frequent door opening and closing.
  • Use in an environment where eyeglasses become foggy.
  • Use in a room filled with cigarette smoke or dust.

If the lens becomes cloudy due to condensation, remove the dome cover and wipe all moist surfaces with a soft cloth.

■ Before operating, please check proper temperature, humidity and power source ratings.

Use the camera under conditions where temperature is between -10 °C – +50 °C and humidity is below 80%.

The input power source is AC 24V.

■ Consumables

Parts having contacts such as the lens-drive motors, cooling fan built inside the camera are subject to wear with time. About replacement and maintenance of such parts, please ask the nearest service center.

Identification of Camera

1 2 3 4 5 6 7 8 9 "A"

1 Camera mounting bracket

The bracket is optional for surface installation.

2 Fall Prevention Wire

Be sure to hook the fall prevention wire into a bracket.

Caution: When you fix the dome cover to the dome camera body, you must insert the wire in the dome camera body. If not, the wire may obstruct the camera's movement.

3 Dome camera body

4 Dome cover

5 Power cable (AC 24V)

6 Video output cable with BNC connector

Connects with the video connector of the monitor.

7 Data Communication Port (RJ45) - RS-485 and Alarm Input

8 Data Communication Port (RJ45) - RS-485 and Alarm Input

9 Data Communication Port (RJ45) - Alarm Output

“A” Do not expose cable connection parts to outdoor conditions such as rain or moisture. It may cause waterproof problems. But if you must, seal them tightly.

Installation

Precautions

  • The following steps of installation and connection work should be done by qualified service personnel or system installers and should conform to all local codes.
  • Be sure to switch the camera off before installation and connection.
  • Do not install the camera near the air outlet of an air conditioner.
  • Do not touch the dome cover's window.

Mounting the Camera

The figures show an example of the camera mounted on a ceiling or wall with a locally procured bracket. Refer to the instructions included with the bracket for filling gaps and holes with waterproof material.

Note: The camera has not been evaluated for wall or ceiling mounting.

Removing the Sponge

Before mounting the camera, remove the sponge for camera protection.

Caution: Remove the sponge carefully without leaving any remainder of the sponge in the camera.

Sponge

Ceiling mount (LPT-EI551PS / LPT-EI553PS)

The Ceiling The Ceiling

Pendant mount (LPT-EP551PS / LPT-EP553PS)

Wall mount (LPT-EP551PS / LPT-EP553PS)

"A"

■ How to install

Join the cylinder (a) to the bracket (b) then fasten with a bolt (c).

"A" Pipe threads should be clean and rust free. Use a sealer (such as Teflon™ tape or silicone sealer) on the threads.

LG LPT-EP553PS - ■ How to install - 1

Add thread sealing tape.

Note: The pipes and brackets for mounting are not supplied.

Reference: Specifications of LG Standard pipe.

4-M4 TAP PF 1 1/4 TAP 19.5 PF 1 1/8 TAP 14

(b) (c) "A"

(a)

Technical line drawing of a mechanical device with internal components and mounting holes (no text or symbols)

Setting the Switch

The DIP switch of the camera is one 8-bit switch and employs RS-485 communication mode as basic use. Switch settings are read into the camera when the power is turned on. Make sure to turn it off, then turn it back on after changing the switch settings.

RS-485 Parameter Setup

The selected protocol, communication parameters, and set unit numbers are read into the camera when power is switched on.

  1. Turn off the camera.
  2. Remove the dome cover from the camera.
  3. Separate the dome camera body from the camera mounting bracket.
  4. Set the DIP switch on the bottom part of the camera according to the function shown in the table below.
  5. Turn on the camera. Setup is completed.

ON 1 2 3 4 5 6 7 8 ON OFF

SW2 on main board

Switch position (5~8)Function Effect
When the camera is connected to the controller with LG Multix protocol.The controller with LG Multix protocol allow all control for this camera.
When the camera is connected to the controller with LG protocol.The controller with LG protocol allow only limited control for this camera.

Note: If you are not using the controller with LG protocol, there may be some limitation of function control.

Switch position (1~4)Function Effect
Baud Rate 9,600 BPS communication speed
Baud Rate 1,200 BPS communication speed
Baud Rate 2,400 BPS communication speed
Baud Rate 4,800 BPS communication speed
Baud Rate 19,200 BPS communication speed
Baud Rate 38,400 BPS communication speed
Baud Rate 57,600 BPS communication speed
Baud Rate 115,200 BPS communication speed

Alarm Output Mode Setting

You can set the Alarm Output to the normal open or normal close mode.

ON 1 2 3 4 5 6 7 8 ON OFF

SW1 on IF board

Alarm Output NumberSwitch Number (Position)Function Effect
11 (ON), 2 (OFF)Normal Open mode
1 (OFF), 2 (ON)Normal Close mode
23 (ON), 4 (OFF)Normal Open mode
3 (OFF), 4 (ON)Normal Close mode
35 (ON), 6 (OFF)Normal Open mode
5 (OFF), 6 (ON)Normal Close mode
47 (ON), 8 (OFF)Normal Open mode
7 (OFF), 8 (ON)Normal Close mode

Camera ID Setting

This camera has the camera ID set to "0" at the time of the shipment. If you use 2 cameras or more simultaneously, change the ID to "2" using the 8-bit DIP switch of the 2 camera with a screwdriver.

Set the camera ID setting referring to the pictures and the table on the below.

• The default setting of the camera ID is 0.

ON 1 2 3 4 5 6 7 8

SW1 on main board

The table for the camera ID setting

  • The connections should be made by qualified service personnel or system installers in accordance with all local codes. • AC 24V can be used.

Note: When powered up, the unit performs a self-check (including one panning, tilting, zooming and focusing operation).

RS-485 Connection

Use the cable that is described below for RS-485 site communication.

• Shielded, twisted pair cable - Low impedance - Wire gauge size is thicker than AWG #22 (0.33 mm 2 ).

ALARM IN Connections

An 8-pin harness is supplied with the camera as standard accessories. Connect external sensors to this connector. Input specifications are low-active, non-voltage contact (ON when active) or open collector (Low when active).

Cautions

  • Alarm input connection must be connected to only one port of two communication ports.
  • Do not connect one alarm sensor to the several camera's alarm input connector.

What is Alarm Input function?

This speed dome camera has a terminal that can sense the alarm signals.

If the alarm sensor that has installed in a door, window, safe etc. sense a touch or shock, the alarm sensor send the alarm signal to the camera and the camera will observe the sensed position.

There are "Manual mode" and "Auto mode" for the Alarm Input function.

- Manual mode: Change the observe position to a sensor that senses a touch or shock then keep observe the sensed position. (Set the Duration Time of Alarm Input function to "0".)

graph TD A["Before Inputting the alarm signal"] --> B["Alarm signal Input"] B --> C["Preset 4"] B --> D["Alarm 4"] B --> E["Preset 8"] E --> F["Alarm 8"]

- Auto mode: Change the observe position to a sensor that senses a touch or shock then return to the position that previously observed. (Set the Duration Time of Alarm Input function to "1 to 255".)

graph TD A["Before inputting the alarm signal"] --> B["Alarm signal input"] B --> C["Released alarm signal"] C --> D["Preset 4"] C --> E["Preset 8"] D --> F["Alarm 4"] E --> G["Alarm 8"]

Note: The Alarm In 1 is Preset 1, Alarm In 2 is Preset 2, Alarm In 3 is Preset 3,..., Alarm In 7 is Preset 7 and Alarm In 8 is Preset 8.

Alarm Input function

Listed below are the camera actions of alarm input function by different function status in each mode

Function statusManual modeAuto mode
While observe a specific position.Change the observe position to the alarmed position then keep observe the alarmed position.Change the observe position to the alarmed position then return to the position that previously observed.
While operating Preset Tour function.Stop preset touring and change the observe position to the alarmed position then keep observe the alarmed position.Stop preset touring and change the observe position to the alarmed position then restart the preset touring again.
While operating Auto Pan function.Stop auto panning and change the observe position to the alarmed position then keep observe the alarmed position.Stop auto panning and change the observe position to the alarmed position then restart the auto panning again.
While operating Pattern function.Stop operating pattern function and change the observe position to the alarmed position then keep observe the alarmed position.Stop operating pattern function and change the observe position to the alarmed position then restart the pattern function again.

ALARM OUT Connections

Connect an external device, for example, a buzzer or lamp, to this connector. Output specifications are low-active, open-collector and a drive capacity of 16 V DC 100 mA maximum.

Note: Use a relay if the voltage or current of the connected device exceeds the ratings.

Data Port ConnectionsData Port A White 8 ALARM IN 4 Blue 7 ALARM IN 3 Green 6 GND Yellow 5 TRX D+ Orange 4 TRX D- Red 3 GND Brown 2 ALARM IN 2 Black 1 ALARM IN 1 To Alarm sensors TXD + RS-485 Connection To Alarm sensors

Data Port B White 8 ALARM IN 8 Blue 7 ALARM IN 7 Green 6 GND Yellow 5 TRX D+ Orange 4 TRX D- Red 3 GND Brown 2 ALARM IN 6 Black 1 ALARM IN 5 To Alarm sensors TXD + RS-485 Connection To Alarm sensors

Data Port C White 8 COM 4 Blue 7 ALARM OUT 4 Green 6 COM 3 Yellow 5 ALARM OUT 3 Orange 4 COM 2 Red 3 ALARM OUT 2 Brown 2 COM 1 Black 1 ALARM OUT 1 To Alarm indicator 4 To Alarm indicator 3 To Alarm indicator 2 To Alarm indicator 1

System Connection

Note: When any peripheral is turned off and turned on again, the camera is also turned off and turned back on.

graph TD A["To alarm indicators"] --> B["Controller"] B --> C["DVR"] C --> D["Alarm In #1"] D --> E["Adapter (Supplied)"] E --> F["Alarm In #2"] E --> G["Alarm In #3"] E --> H["Alarm In #4"] F --> I["Adapter (Supplied)"] G --> J["Adapter (Supplied)"] H --> K["Adapter (Supplied)"] L["Caution: Connect…

Caution: Do not connect the alarm connectors to the another camera's alarm connectors.

Adapter Connections

The adapter is used to connect to another camera, alarm sensor, or controller with RS-485 protocol, etc.

graph LR A["Data Port A"] --> B["Brown"] A --> C["Blue"] A --> D["Yellow"] A --> E["Green"] A --> F["Red"] A --> G["Black"] A --> H["Orange"] A --> I["White"] B --> J["1 ALARM IN 1"] C --> K["2 ALARM IN 2"] D --> L["3 GND"] E --> M["4 TRX D-"] F --> N["5 TRX D+"] G --> O["6 GND"] H --> P["7 ALARM IN…

graph LR A["Data Port B"] --> B["Brown"] A --> C["Blue"] A --> D["Yellow"] A --> E["Green"] A --> F["Red"] A --> G["Black"] A --> H["Orange"] A --> I["White"] B --> J["1 ALARM IN 5"] C --> K["2 ALARM IN 6"] D --> L["3 GND"] E --> M["4 TRX D-"] F --> N["5 TRX D+"] G --> O["6 GND"] H --> P["7 ALARM IN…

graph TD A["Data Port C"] --> B["Brown"] A --> C["Blue"] A --> D["Yellow"] A --> E["Green"] A --> F["Red"] A --> G["Black"] A --> H["Orange"] A --> I["White"] B --> J["1 ALARM OUT 1"] B --> K["2 COM 1"] D --> L["3 ALARM OUT 2"] D --> M["4 COM 2"] F --> N["5 ALARM OUT 3"] F --> O["6 COM 3"] H --> P["…

Setup Menu

Setup Menu Overview

Setup menus are shown in the table below. You can adapt the camera to your requirements by setting up the respective items in these menus. Menus are incorporated in a hierarchical structure, from the setup menu at the top to manual mask area selection at the bottom. These menus are described on the following pages for reference. Switches, keys and the joystick are used in the setup operations

Main MenuSub MenuPage
CAMERA ID22
FOCUS SETFOCUS MODE22
FOCUS DIST22
ZOOM START23
ZOOM END23
ZOOM SPEED23
ZTRK MODE23
AWB SETWBC MODE24
RED ADJUST24
BLUE ADJUST24
AE MODEAE MODE25
IRIS ADJUST25
AGC ADJUST26
BRIGHTNESS26
BACKLIGHT26
E SENSITIVE27
FLICKERLESS27
SHUTTER27
AE LEVELBLC LEVEL28
WDR LEVEL28
Main MenuSub MenuPage
SPECIAL SETUSER TITLE29
SHARPNESS29
COLOR30
NEGATIVE30
D EFFECT30
MOTION DETDETECTION31
LEVEL SET31
OSD DISPFUNCTION31
MOTION DET31
CAMERA ID31
ZOOM MAG31
USER TITLE31
INIT TITLE31
P MASKING32
EXITExits the menu.-

Note: The Preset, Auto Pan, Pattern, Alarm, Privacy Mask functions could not be set on the OSD menu. To set these functions, use LCC-K1000 protocol or Multix protocol.

Setting Camera Menu

The buttons on the connected controller are used for setup.

LCC-K1000 Controller (Optional) OSD button CLR (CLEAR) button Arrow buttons SEL (SELECT) button FOCUS buttons ZOOM buttons

LCC-S100 Controller (Optional) OSD button FOCUS buttons ZOOM buttons ENT (ENTER) button Arrow buttons CLR (CLEAR) button

Open Menu Display

  1. Select the number of the camera you want to set up and a monitor to display MENU.
  2. LCC-K1000: Press OSD button on the controller. LCC-S100: Press OSD button on the controller, then use arrow (♠, ♦) to select [CAM OSD CALL] option, then press ENT button. MENU appears on the monitor. Note: Please refer to the manuals of the controller for details.
  3. Use arrow (♠, ♦) to select an option, then press SEL (or ENT) button. Submenu appears on the monitor.
MENU
CAMERA ID0
FOCUS SET1
AWB SET1
AE MODE1
AE LEVEL1
SPECIAL SET1
MOTION DET1
F OSD DISP1
P MASKING1
EXIT1
FOCUS
FOCUS MODEPUSH AUTO
FOCUS DIST50CM
ZOOM STARTx1
ZOOM ENDx54
ZOOM SPEEDQUICK
ZTRK MODEAUTO
INITIAL SETON
RETURN
  1. Use arrow (↑, ↓) to select a submenu option.
  2. Use arrow (♠, ♦) to select a value.
  3. To close MENU, select [EXIT] option on the MENU, then press SEL (or ENT).

To return to MENU screen from submenu

Use arrow (♠, ♦) to select [RETURN] option, then press SEL (or ENT) button on the submenu.

To exit MENU screen

Use arrow (↑, ↓) to select [EXIT] option, then press SEL (or ENT) button on the main menu.

To reset your parameters to the factory default settings

Use arrow (↑, ↓) to select [INITIAL SET] option, then press SEL (or ENT) button on the menu.

Camera Identification Setting

Only displays the camera's ID. Use the internal 8-bit DIP switch if you want to set ID.

- Camera ID 0 can control all cameras independent of camera ID number.

MENU CAMERA ID 0 FOCUS SET 1 AWB SET 1 AE MODE 1 AE LEVEL 1 SPECIAL SET 1 MOTION DET 1 F OSD DISP 1 P MASKING 1 EXIT 1

Focus Settings

To avoid AF error or out of focus, initialization of the LENS system by using the "Remote Reset" command of the Controller is highly recommended.

General Operation

  1. Move the cursor to [FOCUS SET] on the [MENU] screen.
  2. Press the right key and the FOCUS setting menu appears.

FOCUS FOCUS MODE PUSH AUTO FOCUS DIST 50CM ZOOM START x1 ZOOM END x54 ZOOM SPEED QUICK ZTRK MODE AUTO INITIAL SET ON RETURN ↓

  1. Move the cursor to the desired option.
  2. Select an option (or value).
  3. To reset the [FOCUS] settings to factory settings, use the [INITIAL SET] option on the [FOCUS] menu.
  4. To return to the previous menu, use the [RETURN] option on the [FOCUS] menu.

Focus Mode setting

Select the [FOCUS MODE] option on the [FOCUS] menu, then select the following mode.

  • PUSH AUTO: Auto-focus is activated only when the Push Auto key on the controller is pressed.
  • MANUAL: Focus is activated only when the FOCUS (NEAR or FAR) keys on the controller are pressed.
  • AUTO: Auto-focus is activated automatically while a manual pan, tilt or zoom operation is performed.

Note: If you press the FOCUS (NEAR or FAR) button on the controller while Auto-focus mode, the focus mode is automatically changed to [MANUAL].

FOCUS FOCUS MODE PUSH AUTO FOCUS DIST 50CM ZOOM START x1 ZOOM END x54 ZOOM SPEED QUICK ZTRK MODE AUTO INITIAL SET ON RETURN ↓

Focus Distance setting

Selects the minimum shooting distance for the focus.

Select [FOCUS DIST] option on the [FOCUS] menu, then select a Focus Distance value. (1CM, 10CM, 50CM, 1M, 3M, 5M)

FOCUS FOCUS MODE PUSH AUTO FOCUS DIST 50CM ZOOM START x1 ZOOM END x54 ZOOM SPEED QUICK ZTRK MODE AUTO INITIAL SET ON RETURN ↓

Zoom Start setting

Selects a zoom start position.

Select [ZOOM START] option on the [FOCUS] menu, then select a zoom's start position. (x1 - x26)

FOCUS
FOCUS MODEPUSH AUTO
FOCUS DIST50CM
ZOOM STARTx1
ZOOM ENDx54
ZOOM SPEEDQUICK
ZTRK MODEAUTO
INITIAL SETON
RETURN

Zoom End setting

Selects a zoom end position.

Select [ZOOM END] option on the [FOCUS] menu, then select a zoom's end position. (Zoom Start position+1 - x54)

FOCUS
FOCUS MODEPUSH AUTO
FOCUS DIST50CM
ZOOM STARTx1
ZOOM ENDx54
ZOOM SPEEDQUICK
ZTRK MODEAUTO
INITIAL SETON
RETURN

Zoom Speed setting

Selects a zoom speed.

Select [ZOOM SPEED] option on the [FOCUS] menu, then select a zoom speed. (SLOW, MIDDLE, QUICK)

FOCUS
FOCUS MODEPUSH AUTO
FOCUS DIST50CM
ZOOM STARTx1
ZOOM ENDx54
ZOOM SPEEDQUICK
ZTRK MODEAUTO
INITIAL SETON
RETURN

Zoom Tracking Mode setting

Selects a zoom tracking mode. Zoom tracking means focused zooming state.

Select [ZTRK MODE] option on the [FOCUS] menu, then select a zoom tracking mode (AUTO, MANUAL).

FOCUS
FOCUS MODEPUSH AUTO
FOCUS DIST50CM
ZOOM STARTx1
ZOOM ENDx54
ZOOM SPEEDQUICK
ZTRK MODEAUTO
INITIAL SETON
RETURN

White Balance Control Settings

You can set the white balance options using the [AWB] menu.

General Operation

  1. Move the cursor to [AWB SET] on the [MENU] screen

MENU CAMERA ID 0 FOCUS SET 1 AWB SET 1 AE MODE 1 AE LEVEL 1 SPECIAL SET 1 MOTION DET 1 F OSD DISP 1 P MASKING 1 EXIT 1

  1. Press the right key and the AWB setting menu appears.

AWB WBC MODE AUTO RED ADJUST NOT USED BLUE ADJUST NOT USED INITIAL SET ON RETURN 1

  1. Move the cursor to the desired option.
  2. Select an option (or value).
  3. To reset the [AWB] settings to factory setting, use [INITIAL SET] option on the [AWB] menu.
  4. To return to the previous menu, use [RETURN] option on the [AWB] menu.

Setting the WBC (White Balance Control) Mode

You can select one of four modes for white balance adjustment.

Select [WBC MODE] option on the [AWB] menu, then select the following mode.

- AUTO (Auto-Tracing White Balance): In this mode, the color temperature is monitored continuously and thereby white balance is automatically set. The color temperature range for the proper white balance is approximately 2500 - 9500K. Proper white balance may not be obtained under the following conditions:

1) The color temperature is out of the 2,500 - 9,500K range. 2) When the scene contains mostly high color temperature objects, such as a blue sky or sunset. 3) When the scene is dim.

  • INDOOR: The color temperature range for proper white balance is approximately 3200K.
  • OUTDOOR: The color temperature range for proper white balance is approximately 5,100K.
  • MANUAL: You can set the white balance options manually.

1) RED ADJUST: Obtains the optimum amount of red gain. 2) BLUE ADJUST: Obtains the optimum amount of blue gain.

AWB WBC MODE MANUAL RED ADJUST 124 BLUE ADJUST 92 INITIAL SET OFF RETURN ↓

- PUSH AUTO: The White Balance will be adjusted automatically.

Exposure Settings

You can set the exposure options using the [AE] menu.

General Operation

  1. Move the cursor to [AE] on the [MENU] screen.

MENU CAMERA ID 0 FOCUS SET ↓ AWB SET ↓ AE MODE ↓ AE LEVEL ↓ SPECIAL SET ↓ MOTION DET ↓ F OSD DISP ↓ P MASKING ↓ EXIT ↓

  1. Press the right key and the exposure setting menu appears.

AE AE MODE AUTO IRIS ADJUST AUTO AGC ADJUST AUTO BRIGHTNESS 128 BACKLIGHT OFF E SENSITIVE x10 AUTO FLICKERLESS OFF SHUTTER AUTO INITIAL SET ON RETURN ↓

  1. Move the cursor to the desired option.
  2. Select an option (or value).
  3. To reset the [AE] settings to factory settings, use the [INITIAL SET] option on the [AE] menu.
  4. To return to the previous menu, use the [RETURN] option on the [AE] menu.

AE Mode setting

Selects an Automatic Exposure mode.

Select [AE MODE] option on the [AE] menu, then select an Automatic Exposure mode.

  • AUTO: Use to compensate the exposure automatically.
  • IRIS MAN: Use to change the value of Lens' Iris (IRIS of lens is fixed manually, and the action of exposure compensation depend on its of AGC).
  • SLOW MAN: The change of Electronic Sensitive is available (x1 FIX - x20 FIX). (Electronic Sensitive of camera is fixed manually.)
  • SHUT MAN: Use to change the Shutter Speed control. In this time, AE mode act automatically (10 steps control is available).
AE
AE MODEAUTO
IRIS ADJUSTAUTO
AGC ADJUSTAUTO
BRIGHTNESS128
BACKLIGHTOFF
E SENSITIVEx10 AUTO
FLICKERLESSOFF
SHUTTERAUTO
INITIAL SETON
RETURN

Iris Adjust setting

Selects a iris' exposure value. This option is available only when [AE MODE] is set to [IRIS MAN].

Select [IRIS ADJUST] option on the [AE] menu, then select a value. (0 - 255)

AE
AE MODEAUTO
IRIS ADJUSTAUTO
AGC ADJUSTAUTO
BRIGHTNESS128
BACKLIGHTOFF
E SENSITIVEx10 AUTO
FLICKERLESSOFF
SHUTTERAUTO
INITIAL SETON
RETURN

Automatic Gain Control (AGC) setting

If the images are too dark, change the maximum [AGC] value to make the images lighter. This option is available only when [AE MODE] is set to [SLOW MAN] or [SHUT MAN].

Select [AGC ADJUST] option on the [AE] menu, then select a value. (0 - 7)

AE AE MODE AUTO IRIS ADJUST AUTO AGC ADJUST 0 BRIGHTNESS 128 BACKLIGHT OFF E SENSITIVE x10 AUTO FLICKERLESS OFF SHUTTER AUTO INITIAL SET ON RETURN 1

Brightness Setting

The lens iris is fixed at the value that you have set regardless of the brightness of an object. This option is available only when [AE MODE] is set to [AUTO].

Select [BRIGHTNESS] option on the [AE] menu, then select a value. (0 - 255)

AE AE MODE AUTO IRIS ADJUST AUTO AGC ADJUST 0 BRIGHTNESS 128 BACKLIGHT OFF E SENSITIVE x10 AUTO FLICKERLESS OFF SHUTTER AUTO INITIAL SET ON RETURN 1

Backlight Setting

Improves an image that is darkened because of backlighting.

Select [BACKLIGHT] option on the [AE] menu, then select a value.

AE AE MODE AUTO IRIS ADJUST AUTO AGC ADJUST 0 BRIGHTNESS 128 BACKLIGHT OFF E SENSITIVE x10 AUTO FLICKERLESS OFF SHUTTER AUTO INITIAL SET ON RETURN ↓

• OFF: The back light compensation is not used. • ON: The back light compensation is used. - AUTO (Auto back light compensation): If you use an ordinary camera when there is an intense and concentrated illumination behind an object, the back light will shade the image on the monitor screen. The Backlight function prevents such a back light effect to secure a clear image under all illumination environments. - WDR: The WDR camera is state of the art to enlarge the screen profit effectively, especially for taking photos of a window in a building. In short it revives both the indoor and outdoor status as they are clearly.

Electronic Sensitive setting

The electronic sensitivity enhancement function varies the shutter speed to increase the sensitivity in low light conditions.

This option is available only when [AE MODE] is set to [AUTO] or [SLOW MAN].

Select [E SENSITIVE] option on the [AE] menu, then select a value.

There are two modes for Electronic Sensitive as follows:

AUTO mode: OFF, x2 AUTO - x20 AUTO (If you select x20 AUTO, the sensitivity is increased automatically up to x20.)

SLOW MAN mode: x1 FIX - x20 FIX (If you select x20 FIX, the sensitivity is increased to a fixed x20.)

AE AE MODE AUTO IRIS ADJUST AUTO AGC ADJUST 0 BRIGHTNESS 128 BACKLIGHT OFF E SENSITIVE x10 AUTO FLICKERLESS OFF SHUTTER AUTO INITIAL SET ON RETURN 1

Flickerless Setting

Use for removing the flicker of picture. This option is available only when [AE MODE] is set to [AUTO].

Select [FLICKERLESS] option on the [AE] menu, then select an option (ON or OFF). Set to [ON] to remove the flicker.

AE AE MODE AUTO IRIS ADJUST AUTO AGC ADJUST 0 BRIGHTNESS 128 BACKLIGHT OFF E SENSITIVE x10 AUTO FLICKERLESS OFF SHUTTER AUTO INITIAL SET ON RETURN 1

Shutter Speed Setting

You can select a shutter speed from among AUTO, 1/120, 1/250, 1/500, 1/1000, 1/2000, 1/4000, 1/10000, 1/20000 and 1/50000 seconds.

This option is available only when [AE MODE] is set to [AUTO] and [FLICKERLESS] option is set to [OFF].

Select [SHUTTER] option on the [AE] menu, then select a shutter speed.

AE AE MODE AUTO IRIS ADJUST AUTO AGC ADJUST 0 BRIGHTNESS 128 BACKLIGHT OFF E SENSITIVE x10 AUTO FLICKERLESS OFF SHUTTER AUTO INITIAL SET ON RETURN ↻

Auto Exposure Level Settings

You can set the auto exposure options using the [AE LEVEL] menu.

General Operation

  1. Move the cursor to [AE LEVEL] on the [MENU] screen

MENU CAMERA ID 0 FOCUS SET 1 AWB SET 1 AE MODE 1 AE LEVEL 1 SPECIAL SET 1 MOTION DET 1 F OSD DISP 1 P MASKING 1 EXIT 1

  1. Press the right key and the auto exposure level setting menu appears.

AE LEVEL BLC LEVEL 176 WDR LEVEL 6 INITIAL SET ON RETURN 1

  1. Move the cursor to the desired option.
  2. Select an option (or value).
  3. To reset the [AE LEVEL] settings to factory setting, use [INITIAL SET] option on the [AE LEVEL] menu.
  4. To return to the previous menu, use [RETURN] option on the [AE LEVEL] menu.

BLC (Back Light Compensation) Level Setting

Selects a level for the BLC (back light compensation).

Select [BLC LEVEL] option on the [AE LEVEL] menu, then select a desired level (0-255).

AE LEVEL BLC LEVEL 176 WDR LEVEL 6 INITIAL SET ON RETURN 1

WDR (Wide Dynamic Range) Level setting

Selects a level for the WDR (Wide Dynamic Range).

Select [WDR LEVEL] option on the [AE LEVEL] menu, then select a desired level (0-255).

AE LEVEL BLC LEVEL 176 WDR LEVEL 6 INITIAL SET ON RETURN ↓

Special Settings

You can set the special options using the [SPECIAL] menu.

General Operation

  1. Move the cursor to [SPECIAL SET] on the [MENU] screen

MENU CAMERA ID 0 FOCUS SET ↓ AWB SET ↓ AE MODE ↓ AE LEVEL ↓ SPECIAL SET ↓ MOTION DET ↓ F OSD DISP ↓ P MASKING ↓ EXIT ↓

  1. Press the right key and the [SPECIAL] setting menu appears.

SPECIAL USER TITLE SHARPNESS 112 COLOR ON NEGATIVE OFF D.EFFECT NONE INITIAL SET ON RETURN ↓

  1. Move the cursor to the desired option.
  2. Select an option (or value).
  3. To reset the [SPECIAL] settings to factory setting, use [INITIAL SET] option on the [SPECIAL] menu.
  4. To return to the previous menu, use [RETURN] option on the [SPECIAL] menu.

User Title Setting

You can name the camera independently.

  1. Move the cursor to [USER TITLE] on the [SPECIAL] menu. An arrow mark appears.
  2. Move the arrow mark to the desired position, then select a character.
  3. Repeat step 2 to set the remaining characters.

SPECIAL USER TITLE SHARPNESS 112 COLOR ON NEGATIVE OFF D EFFECT NONE INITIAL SET ON RETURN ↓

Sharpness Setting

Sharpens the image outline. Select the [SHARPNESS] option on the [SPECIAL] menu, then select a value (0 - 255).

SPECIAL USER TITLE □□□□□□□□□□□ SHARPNESS 112 COLOR ON NEGATIVE OFF D EFFECT NONE INITIAL SET ON RETURN ↓

Color Setting

You can switch the displayed picture to grayscale or color.

Select the [COLOR] option on the [SPECIAL] menu, then select an option (ON or OFF). Set to [ON] to display the picture in color. Set to [OFF] to display the picture in grayscale.

SPECIAL USER TITLE SHARPNESS 112 COLOR ON NEGATIVE OFF D EFFECT NONE INITIAL SET ON RETURN ↓

Negative Setting

You can use the negative effect.

Select the [NEGATIVE] option on the [SPECIAL] menu, then select an option (ON or OFF).

SPECIAL USER TITLE SHARPNESS 112 COLOR ON NEGATIVE OFF D EFFECT NONE INITIAL SET ON RETURN ↓

Digital Effect Setting

You cannot set a Digital Effect option.

SPECIAL USER TITLE SHARPNESS 112 COLOR ON NEGATIVE OFF D EFFECT NONE INITIAL SET ON RETURN ↓

Motion Detection Setting

The motion detection detects moving objects in the scene by monitoring changes in brightness level. You can select the level of sensitivity for motion detection.

When this camera is connected to a compatible intelligent CCTV system, the camera transmits an alarm signal by multiplexing it with the video signal.

  1. Move the cursor to [MOTION DET] on the [MENU] screen.

MENU CAMERA ID 0 FOCUS SET ↓ AWB SET ↓ AE MODE ↓ AE LEVEL ↓ SPECIAL SET ↓ MOTION DET ↓ F OSD DISP ↓ P MASKING ↓ EXIT ↓

  1. Press the right key and the [MOTION] setting menu appears.

MOTION DETECTION ON LEVEL 10 DAY/NIGHT AUTO INITIAL SET ON RETURN ↓

  1. Set [DETECTION] option to [ON] to use.
  2. Use [LEVEL] option to obtain the optimum detection level (21 levels).
  3. Use [DAY/NIGHT] option for day/night function. AUTO: The camera selects black and white mode if the picture is dark, or color mode if the picture is bright enough. NIGHT: Black-and-white mode enabled. DAY: Color mode enabled.
  4. To reset the [MOTION] settings to factory setting, use [INITIAL SET] option on the [MOTION] menu.
  5. To return to the previous menu, use [RETURN] option on the [MOTION] menu.

Function On-Screen Display Setting

You can set the Function On-Screen Display options using the [F OSD] menu.

The Function On-Screen Display of this camera can be turned on or off.

  1. Move the cursor to [F OSD DISP] on the [MENU] screen.

MENU CAMERA ID 0 FOCUS SET ↓ AWB SET ↓ AE MODE ↓ AE LEVEL ↓ SPECIAL SET ↓ MOTION DET ↓ F OSD DISP ↓ P MASKING ↓ EXIT ↓

  1. Press the right key and the [F OSD] setting menu appears.

F OSD FUNCTION DISP ON MOTION DET DISP ON CAMERA ID DISP ON ZOOM MAG DISP ON USER TITLE DISP ON INIT TITLE DISP ON INITIAL SET ON RETURN ↓

  1. Select an option (DISP ON or OFF).
  2. DISP ON: Displays the Function On-Screen Display on the screen.
  3. OFF: The Function On-Screen Display does not appear on the screen.
  4. To reset the [F OSD] settings to factory settings, use the [INITIAL SET] option on the [F OSD] menu.
  5. To return to the previous menu, use the [RETURN] option on the [F OSD] menu.

Privacy Masking Settings

Using the LCC-K1000 or controller with Multix protocol for Privacy Zone Setting.

This function is aimed at protecting personal privacy by selecting a screen part to be blackened so that it is not displayed on the screen.

Up to 8 zones can be registered. Submenus are provided for zone number selection and parameter setting.

To register a new privacy zone using the LCC-K1000:

  1. Press the Set Up button, then select the [PRIVACY ZONE] icon.

PRIVACY ZONE 000 PTZ

  1. Press SEL.

The sub menu will appear for [PRIVACY ZONE] setting.

  1. Select [Set Zone Area] option then press SEL. The sub menu will appear.

graph TD A["PTZ 000"] --> B["Set Zone Area<br>Display Zone Area"] B --> C["[▲▼:◄►"]] D["PTZ 000"] --> E["[Set Privacy Zone"] Zone Index: --- (1 ~ 8)] E --> F["[Num"]]

  1. Use number buttons to select the zone index number then press SEL to confirm. The blue zone frame appears on the center of monitor.

Two gray squares side by side, one rotated relative to the other (no text or symbols)

  1. Adjust the pan, tilt, and zoom position so that the desired position comes into the zone frame with the joystick.

You can't move privacy mask zone and you can't change the size of privacy mask zone.

  1. Press SEL.

The mask color will be change into grey.

The privacy zone setting has been completed and the setting is memorized in the camera's memory.

  1. Repeat steps 3-6 to add additional position.

Reference

Specifications

Signal SystemNTSC (High Resolution)PAL (High Resolution)
Pick-Up Device1/4" EX-view CCD
Total Pixels No.410K470K
S/N RatioMore Than 50 dB
Horizontal ResolutionMore Than 520 TV Lines
LensX 27 Zoom (F 1.5(W), F 3.8(T) f=3.25-88.0 mm)
Shooting DistanceTele (1.2m), Wide (0.01 m)
On Screen DisplayOn/Off (English only)
Image Capture1 field image Freezer, Image rotation, Up and Down inverting
Minimum Illumination1 Lux (F1.5, normal shutter)0.03 Lux (20 Field Accumulated)/0 Lux (Infrared ON: Night Mode)
Digital Zoomx 2: Basic (Off at WDR)
Sync SystemInternal
White BalanceAuto (ATW)/ Indoor/ Outdoor/ Manual/ Push Auto
Control MethodRS-485 Control
Alarm Input8 Channel
Alarm Output4 Channel
Video OutputComposite Output 1 Vp-p, 75Ω
Electronic Shutter1/4- 1/50,000 Sec (10 Step)
Flickerless ModeManual On/Off
Iris ControlAuto / Manual
Wide Dynamic RangeDual Shutter control (128 times of Dynamic Range)
Panning Range (Speed)0° - 360° (240° / Sec)
Tilting Range (Speed)0° - 180° (240° / Sec)
Privacy Zone8 Area Active Programmable Zone
Preset / ID128 Position / 256
Auto Panning2 - 8 points
PatternMax. 8 minutes
Group TourMax. 9 Groups
Operation Temperature-10° - 50°C
Safekeeping Temperature-20° - 60°C
Power SupplyAC 24V
Power ConsumptionMax. 29W
Dimension (ø x H)LPT-EP551PS/LPT-EP553PS: ø230 x 300 mmLPT-EI551PS/LPT-EI553PS: ø220 x 170 mm
WeightLPT-EP551PS/LPT-EP553PS: Approx 3.3KgLPT-EI551PS/LPT-EI553PS: Approx 2.6Kg
Table of contents Click a title to access it
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : LG

Model : LPT-EP553PS

Category : Surveillance Camera