LCP2850 - Surveillance Camera LG - Free user manual and instructions
Find the device manual for free LCP2850 LG in PDF.
| Product Type | Surveillance Camera |
| Brand | LG |
| Model | LCP2850 |
| Camera Type | Indoor/Outdoor IP Camera |
| Resolution | 1920 x 1080 (Full HD) |
| Lens | 2.8mm fixed lens |
| Night Vision | Up to 30m with IR LEDs |
| Field of View | 90° horizontal |
| Dimensions (WxHxD) | 100 x 80 x 70 mm |
| Weight | 350 g |
| Power Supply | 12V DC, 1A (adapter included) |
| Power Consumption | 6W (max) |
| Connectivity | Ethernet (RJ-45), Wi-Fi 802.11b/g/n |
| Storage | MicroSD up to 128GB, NVR compatible |
| Motion Detection | Yes, with push notifications |
| Audio | Two-way audio with built-in mic and speaker |
| Weather Rating | IP66 (dust and water resistant) |
| Operating Temperature | -20°C to 50°C |
| Mounting | Wall or ceiling mount (bracket included) |
| Maintenance | Clean lens with soft dry cloth; keep vents unobstructed |
| Safety | CE, RoHS compliant |
| Spare Parts & Repairability | Contact LG support for replacement parts; professional repair recommended |
Frequently Asked Questions - LCP2850 LG
User questions about LCP2850 LG
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Surveillance Camera in PDF format for free! Find your manual LCP2850 - LG and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. LCP2850 by LG.
USER MANUAL LCP2850 LG
Please read this manual carefully before operating your set and retain it for future reference.
MODEL
LCP2850-AN/AP
LCP2850I-AN/AP
1
Safety Information

CAUTION
RISK OF ELECTRIC SHOCK DO NOT OPEN

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER (OR BACK) NO USER-SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

This lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.

The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product.
Warning: Do not install this equipment in a confined space such as a bookcase or similar unit.
Warning: Wiring methods shall be in accordance with the National Electric Code, ANSI/NFPA 70.
Warning: This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Warning: To reduce a risk of fire or electric shock, do not expose this product to rain or moisture.
Caution: This installation should be made by a qualified service person and should conform to all local codes.
Caution: To avoid electrical shock, do not open the cabinet. Refer servicing to qualified personnel only.
Caution: The apparatus should not be exposed to water (dripping or splashing) and no objects filled with liquids, such as vases, should be placed on the apparatus.
CE
LG Electronics hereby declares that this/these product(s) is/are in compliance with the essential requirements and other relevant provisions of Directive 2004/108/EC and 2011/65/EU.
Contact office for compliance of this product:
LG Electronics Inc.
EU Representative, Krijgsman 1,1186
DM Amstelveen, The Netherlands
Safety Precautions
- Do not attempt to disassemble the camera To prevent electric shock, do not remove screws or covers. There are no user serviceable parts inside. Ask a qualified service personnel for servicing.
- Avoid the camera with direct sunlight Do not aim the camera at bright objects. Whether the camera is in use or not, never face it with direct sunlight or other extremely bright objects. Otherwise blooming or smear may be caused.
- Handle the camera with care Do not abuse the camera. Avoid striking, shaking, etc. The camera could be damaged by improper handling or storage.
- Do not use strong solvents or detergents Use a dry cloth to the camera when it is dirty. If it is hard to remove the dirt on the camera, use a mild detergent and wipe it gently.
- Do not install this camera upside down This camera is designed for mounting on the ceiling or wall. If you install this camera upside down, for example, mounted on the floor, it may cause malfunction.
- Do not use the camera in such places as shown below. The lens may become cloudy due to condensation if the camera is used under the following conditions: rapid temperature fluctuation by switching an air conditioner on and off, rapid temperature fluctuation due to frequent door opening and closing, use in an environment where eyeglasses become foggy, or use in a room filled with cigarette smoke or dust. If the lens becomes cloudy due to condensation, remove the dome cover and wipe all moist surfaces with a soft cloth.
- Before operating, please check proper temperature, humidity, and power source ratings. Use the camera under conditions where temperature is from -20 °C to 50 °C and humidity is below 80%. The input power source is AC 24 V.
- Consumables
Parts having contacts such as the lens-drive motors and cooling fan built inside the camera are subject to wear with time. About replacement and maintenance of such parts, please ask the nearest service center.
Camera Installation Location
Discuss the installation location for the camera with your retailer, and select a place that is strong enough for the installation.
• Install the camera on a ceiling (concrete, etc.) at a location that is sufficiently strong to support it. • Install the camera body on the foundation section of the building or sections having sufficient bearing strength.
Never install or use the camera in the following locations
- Do not install it in areas exposed to direct sunlight or rain.
- Do not install the camera near the air outlet of an air conditioner.
- Near a swimming pool or other areas where chemicals are used.
- Food preparation areas and other locations where there are large amounts of steam vapor and oil, in flammable atmospheres, or other special environments.
- Areas where radiation, X-rays, strong electric waves, or magnetism is generated.
- At sea, in coastal areas, or in areas where corrosive gas is being generated.
- Areas outside of the allowable ambient operating temperature range.
About Static Electricity Removal
Before installing the camera, touch a metal case or other metallic parts with your hand to remove static electricity from your body.
Do not install in areas subjected to high amounts of humidity or dust.
Doing so may cause internal components to damage more easily or malfunction.
Do not wire cables near power lines.
Tightening the Screws
Screws should be tightened sufficiently in accordance with the materials and structure of the installation location. After tightening the screws, visually inspect them to make sure there is no unevenness and that each screw is tight.
Contents
1 Safety Information
4 Safety Precautions
2 Preparation
8 Introduction
8 Features
9 Accessories
10 Part Names and Functions
3 Installation
12 Connections
12 Precautions
12 Basic Connection Overview
13 Connecting Display device
13 ALARM input connection
15 ALARM output connections
17 Connecting LKD1000 controller
17 Connecting RS-485 device
19 Connecting power source 19 Protocol and baud rate settings 20 Camera ID Setting 23 Removing the Protection Tape 24 Mounting the camera 24 Surface mount (optional) 25 Ceiling mount (optional) 27 Wall mount (optional) 29 Pendant mount (Optional)
4 Operation
33 Setup Menu Overview 37 Menu navigation 37 Accessing the camera setup menu 37 General operation 38 Camera menu settings 38 Focus setting 38 Exposure settings 39 White Balance setting 40 Day/Night setting 40 3D-DNR setting 41 Color setting 41 Sharpness setting 41 Stabilizer setting 41 PAN/TILT Settings 41 Preset setting 43 Group tour setting 43 Pattern setting
44 Auto Pan setting 44 Privacy Mask setting 45 Special setting 47 OSD Settings 47 User title setting 47 ZOOM MAG setting 47 FUNCTION setting 48 DOME ID setting 48 LANGUAGE Setting 48 ALARM Setting 48 Alarm In setting 49 Alarm Out setting 49 RESET Setting 49 Information 49 Initialization 49 Camera reset 49 Factory reset
5
Appendix
50 Specifications
2 Preparation
Introduction
The dome cameras are designed for installation in an indoor or outdoor video surveillance system.
The camera incorporates the digital signal processor, pan/tilt mechanism, zoom lens and RS-485 communication interface in a compact outdoor enclosure.
Features
• High Sensitivity Support
The camera provides the high quality picture with 4.5 mm (1/4 Type) Super HAD II CCD.
- Preset Position
Preset position is the function to register camera monitoring positions (preset positions). By using LKD1000 controller, you can register presets with position number. Maximum 256 Preset Positions are available. By entering the position numbers, you can move cameras to the preset positions. The moving speed and holding time are adjustable.
- Preset Tour
Preset Tour is the function to go through all the registered camera monitoring positions (preset positions). During the working PRESET TOUR, The FOCUS could not be operated properly under -20 °C.
- Group Tour
Maximum 10 group tours are able to compose the group of preset, pattern, auto pan that the operator can program to be linked together in a sequence.
• Pattern recording function
A routine of manual operations can be stored and
reproduced repeatedly. The Pan, Tilt and Zoom controls are available for pattern recording.
Note
The available total time of pattern differs depending on camera's operation. When the pattern recording is full, the pattern recording will automatically stop.
- Privacy Mask
Privacy zone feature enables users to veil unwanted zones. This setting is used for masking unwanted zones, hiding them from display on the monitor screen. Up to 8 zones can be registered.
- Auto Pan
The camera has an Auto Pan function that enables to keep surveillance on every detail occurring around the specific area, which is preset to watch in advance. The camera can pan among the maximum 8 points you will set. The moving speed and holding time are adjustable.
- Auto Flip
When the camera is operated to tilt through the 90°, it can be watched the opposite side of the locations by Auto Flip of a 180° horizontally.
• Optical Zoom
- The optical zoom range is 1x to 28x.
- Digital Zoom
Digital zoom enhances the systems zoom range to 12 times beyond the optical zoom limit.
Total system zoom range is below.
- 28x (1x digital zoom) to 336x (12x digital zoom)
• Alarm In function (4 channels)
Alarm input signals are supplied from external devices through the ALARM IN connector to activate 'go to preset' function.
• Alarm Out function (2 channels)
When alarm inputs are supplied via the alarm input connector on the camera, the camera sends output signals via the alarm output connector on the camera.
• Controls by General Controller
This camera can be controlled by RS-485. Especially the camera has an excellent cost-saving effect because it can be controlled by the general RX point of contact signal.
- Connects with the maximum 256 cameras
This camera can be utilized after being connected with maximum 256 cameras. Therefore, it is capable of performing an excellent job in the large buildings or department stores.
• Day & Night Function
This camera can be selected Color or Black & White. You can set Color in the daytime and Black & White at night due to the low illumination. (Filter Conversion type)
• DSS (Digital Slow Shutter) function
It is possible to highly sensitive surveillance because of DSS(Digital Slow Shutter) function.
• WDR (Wide Dynamic Range) function
The camera is best suited for easy viewing both indoors and outdoors in strong backlight conditions.
• Power Supply
This camera must always be operated with an AC 24 V certified/listed adaptor that complies with LPS.
Accessories
For LCP2850I-AN/AP
| RJ-45 Adapter cable | ![]() |
| Camera mounting bracket | ![]() |
For LCP2850-AN/AP
| Camera main cable | ![]() |
| Wrench | ![]() |
| PIPE Installation Bracket | ![]() |
Part Names and Functions
LCP2850I-AN/AP for Indoor
1 BNC connector cover cap 2 Video output BNC connector
Supplies analog video signal (composite) to the connected device.
3 Data Port A (RJ-45)
RS-485 data communication and input data port for alarm (relay) signal.
4 Data Port B (RJ-45)
Output data port for alarm (relay) signal.
5 This port is not used. 6 This port is not used. 7 Power input jack
Connects to an AC 24 V power supply using proper cables.
8 This port is not used. 9 Locking screw
Tighten this screw to fix the Ceiling Mount Assembly with the camera body.
10 Dome Cover open button. 11 Dome Cover
LCP2850-AN/AP for Outdoor
1 BNC connector cover cap 2 Video output BNC connector
Supplies analog video signal (composite) to the connected device.
3 RS-485 Data Communication 4 Alarm In Data Terminal
Input data terminal for alarm (relay) signal.
5 Alarm Out Data Terminal Output data terminal for alarm (relay) signal. 6 Power input Terminal Connects to an AC 24 V power supply using proper cables. 7 Dome Cover
3 Installation
Connections
Precautions
- The following steps of installation and connection work should be done by qualified service personnel or system installers and should conform to all local codes. • Before you install and connect the camera, check and prepare the required peripheral devices and cables. • Before you connect the camera, turn off all devices to be connected, such as this camera and DVR.
- Do not touch the dome cover's window.
Basic Connection Overview
LCP2850I-AN/AP (for Indoor) LCP2850-AN/AP (for Outdoor)
Connecting Display Device
The video signal connection between the camera and the monitor.
Display Device Connection![graph TD A["1"] --> B["2"] B --> C["Laptop"]](/content/2026/06/1405182/images/5cc3ced3fa72ed35003223c6ba354331d2e2f7ff87d01e31b00e4dbc7a644cfd.jpg)
ALARM Input Connection
You can connect up to 4 alarm sensors to the camera. Each alarm sensor should be connected with Alarm IN COM. You can adjust the signal state to NO (normally open) or NC (normally closed) through the setup menu.
For LCP2850I-AN/AP
- Connect the RJ-45 Adaptor cable to the PORT A (RJ-45) cable of the camera.
- Connect the alarm device to the RJ-45 Adaptor cable. When connecting lines, check and connect the color lines of each device correctly. Refer to the below tables for color line information.
Caution
Do not connect one alarm sensor to the several camera's alarm input connector.
Alarm Input Connection![graph TD A["Sensor Input"] --> B["Router"] B --> C{Switch} C --> D["1"] C --> E["2"] C --> F["3"] C --> G["4"] C --> H["5"] C --> I["6"] C --> J["7"] C --> K["8"] D --> L["Alarm device"] E --> M["Alarm device"] F --> N["Alarm device"] G --> O["Alarm device"] H --> P["Alarm device"] I --> Q["Alarm de…](/content/2026/06/1405182/images/241a3d44015d0924639177e97456cc4295e5115d4f8489cdf6bc4eb0d69914c3.jpg)
| RJ-45 Adaptor cable | ||
| No Description Color | ||
| 1 | RS-485 + White | |
| 2 | RS-485 - Orange | |
| 3 | NC Black | |
| 4 | ALARM IN COM Red | |
| 5 | ALARM IN 1 Green | |
| 6 | ALARM IN 2 Yellow | |
| 7 | ALARM IN 3 Blue | |
| 8 | ALARM IN 4 Brown | |
| PORT A | |
| Description Color | |
| RS-485 + Red/White | |
| RS-485 - Black/White | |
| NC | |
| ALARM IN COM Red | |
| ALARM IN 1 | White |
| ALARM IN 2 | Light Green |
| ALARM IN 3 Yellow | |
| ALARM IN 4 Pink | |
For LCP2850-AN/AP
- Connect the Adaptor cable to the Alarm In Data Terminal of the camera.
- Connect the alarm device to the adaptor cable. When connecting lines, check and connect the color lines of each device correctly. Refer to the tables below for color line information.
Caution
Do not connect one alarm sensor to the several camera's alarm input connector.
Alarm input connection![graph LR A["Sensor Input"] --> B["Signal Path"] B --> C{Adaptor Cable} C --> D["1"] C --> E["2"] C --> F["3"] C --> G["4"] C --> H["5"] D --> I["Alarm device"] E --> J["Alarm device"] F --> K["Alarm device"] G --> L["Alarm device"] H --> M["Alarm device"] I --> N["Alarm In Data Terminal"] J --> N K…](/content/2026/06/1405182/images/46fc95decf6189893d8fae3433cbe1119dec7afe33ccfedb22ea3aba6a8b8a15.jpg)
| Adaptor cable | |
| No | Description |
| 1 | ALARM IN 1 |
| 2 | ALARM IN 2 |
| 3 | ALARM IN COM |
| 4 | ALARM IN 3 |
| 5 | ALARM IN 4 |
| Alarm In Data Terminal | |
| Description Color | |
| ALARM IN 1 Pink | |
| ALARM IN 2 Gray | |
| ALARM IN COM Yellow | |
| ALARM IN 3 White | |
| ALARM IN 4 Violet | |
Alarm Input function
This speed dome camera has a terminal that can sense the alarm signals.
If the alarm sensor that has been installed in a door, window, safe, etc. senses a touch or shock, the alarm sensor sends the alarm signal to the camera and the camera will observe the sensed position.
Change the observe position to a sensor that senses a touch or shock, then return to the position that was previously observed. (Set the Duration Time of the Alarm Input function to "3 to 255".)
| Function status | Mode |
| While observe a specific position. | Change the observe position to the alarmed position then return to the position that previously observed. |
| While operating Preset Tour function. | Stop preset touring and change the observe position to the alarmed position then restart the preset touring again. |
| While operating Auto Pan function. | Stop auto panning and change the observe position to the alarmed position then restart the auto panning again. |
| While operating Pattern function. | Stop operating pattern function and change the observe position to the alarmed position during the dwell time then restart the pattern function again. |
| in case of HOME POSITION is ON. | After Alarm has been cleared and finished the dwell time, it moves to the HOME POSITION and spend the dwell time at that position. |

Note
Do not connect one alarm sensor to the several camera's alarm input connector.
ALARM output connections
Connect the alarm device to the alarm output data port. Alarm signal output occurs at an event occurrence. You can set the Alarm Output to the normal open or normal close mode.
For LCP2850I-AN/AP
- Connect the RJ-45 adaptor cable to the PORT B (RJ-45) cable of the camera.
- Connect the alarm device to the RJ-45 adaptor cable. When connecting lines, check and connect the color-coded wires of each device correctly. Refer to the tables below for color line information.
![graph TD A["Sensor Input"] --> B["Switch"] B --> C{Switch} C --> D["1"] C --> E["2"] C --> F["3"] C --> G["4"] C --> H["5"] C --> I["6"] C --> J["7"] C --> K["8"] D --> L["Alarm device"] E --> M["Alarm device"] F --> N["Alarm device"] G --> O["Alarm device"] H --> P["Alarm device"] I --> Q["Alarm de…](/content/2026/06/1405182/images/a1f4b7e2082d11f9df717b800fce8e617e035a51b1f12ba19ae6f8bb19333c0d.jpg)
| RJ-45 Adaptor cable | ||
| No Description Color | ||
| 1 | ALARM OUT [NO1] | White |
| 2 | ALARM OUT [COM1] Orange | |
| 3 | ALARM OUT [NC1] Black | |
| 4 | NC Red | |
| 5 | ALARM OUT [NO2] Green |
| 6 | ALARM OUT [COM2] Yellow |
| 7 | ALARM OUT [NC2] Blue |
| 8 | NC Brown |
| PORT B | |
| Description Color | |
| ALARM OUT [NC1] Blue | |
| ALARM OUT [COM1] Violet | |
| ALARM OUT [NO1] Brown | |
| NC | |
| ALARM OUT [NC2] Gray | |
| ALARM OUT [COM2] | Orange |
| ALARM OUT [NO2] Black | |
| NC | |
For LCP2850-AN/AP
- Connect the adaptor cable to the Alarm Out Data Terminal of the camera.
- Connect the alarm device to the adaptor cable. When connecting lines, check and connect the color-coded wires of each device correctly. Refer to the tables below for color line information.
Alarm Out connection![graph TD A["Adaptor Cable"] --> B["1"] A --> C["2"] A --> D["3"] A --> E["4"] A --> F["5"] A --> G["6"] B --> H["Alarm device"] C --> I["Alarm device"] D --> J["Alarm device"] E --> K["Alarm device"] F --> L["Alarm device"] G --> M["Alarm device"] H --> N["Alarm Out Data Terminal"] I --> N J --> N K…](/content/2026/06/1405182/images/40bd0ce97728265a45ddd691ed3febed107d860cbcd51ad3c8b5d1a5cc5bdd0e.jpg)
| Adaptor cable | |
| No Description | |
| 1 | ALARM OUT [NO1] |
| 2 | ALARM OUT [COM1] |
| 3 | ALARM OUT [NC1] |
| 4 | NC |
| 5 | ALARM OUT [NO2] |
| 6 | ALARM OUT [COM2] |
| 7 | ALARM OUT [NC2] |
| 8 | NC |
| Alarm Out Data Terminal | |
| Description Color | |
| ALARM OUT [NO1] White Blue | |
| ALARM OUT [COM1] Beige | |
| ALARM OUT [NC1] Black | |
| ALARM OUT [NO2] Brown | |
| ALARM OUT [COM2] Red | |
| ALARM OUT [NC2] | Orange |
Connecting LKD1000 controller
For LCP2850I-AN/AP
- Connect the RJ-45 adaptor cable to the PORT A (RJ-45) cable of the camera.
- Connect the LKD1000 controller to the RJ-45 adaptor cable. (Refer to the manuals of the LKD1000 controller for more details.)
LKD1000 connection![graph TD A["Input Image"] --> B["Switch"] B --> C["Output Image"] D["RJ-45 Adaptor cable"] --> E["Port A"] style A fill:#f9f,stroke:#333 style E fill:#bbf,stroke:#333](/content/2026/06/1405182/images/312e06ad32c0c9290da45e63ca5ed428574ecd36dade282f3796d1219aa0d0c1.jpg)
| RJ-45 Adaptor cable | ||
| No Description Color | ||
| 1 | RS-485 + White | |
| 2 | RS-485 - Orange | |
For LCP2850-AN/AP
- Connect the adaptor cable to the RS-485 Data Communication of the camera.
- Connect the LKD1000 controller to the adaptor cable. (Refer to the manuals of the LKD1000 controller for more details.)
LKD1000 connection![graph TD A["Adaptor cable"] --> B["TX+"] A --> C["TX-"] B --> D["RS-485 Data Communication"] C --> D](/content/2026/06/1405182/images/9ce0954bddf338c1f0c12d6fe5604026d5245a6178a000c04f2f602106eceb41.jpg)
| Adaptor cable | |
| No Description | |
| 1 | RS-485 + |
| 2 | RS-485 - |
Connecting RS-485 device
Use the cable described below for RS-485 site communication.
• Shielded, twisted pair cable - Low impedance • Wire gauge size is thicker than AWG #22 (0.33 mm²).
For LCP2850I-AN/AP
RS-485 connection![graph TD A["Input Image"] --> B["RS-485 device"] B --> C["RX+"] B --> D["RX-"] C --> E["1"] C --> F["2"] C --> G["3"] C --> H["4"] C --> I["5"] C --> J["6"] C --> K["7"] C --> L["8"] D --> M["RS-485 device"] E --> N["Port A"] F --> N G --> N H --> N I --> N J --> N K --> N L --> N](/content/2026/06/1405182/images/ad1a0d7f61a5d3952e5da94ac81165129c012e2a1d70c64e868605e0f9120570.jpg)
- Connect the RJ-45 adaptor cable to the PORT A (RJ-45) cable of the camera.
- Connect the RS-485 device to the RJ-45 adaptor cable. When connecting lines, connect the "Orange color line" of the RJ-45 adaptor cable to "RX -" of the RS-485 unit and the "White color line" of the RJ-45 adaptor cable to "RX +" of the RS-485 unit correctly.
| RJ-45 Adaptor cable | ||
| No Description Color | ||
| 1 | RS-485 + White | |
| 2 | RS-485 - | Orange |
| PORT A | |
| Description Color | |
| RS-485 + Red/White | |
| RS-485 - Black/White | |
For LCP2850-AN/AP
RS-485 connection![graph TD A["Adaptor cable"] -->|RX+| B["RS-485 device"] A -->|RX-| B B --> C["RS-485 Data Communication"]](/content/2026/06/1405182/images/00c40235e2876ab6c4bee5437655fb5f88e0ed0c8814ebaeb654278560adf133.jpg)
- Connect the adaptor cable to the RS-485 Data Communication of the camera.
- Connect the RS-485 device to the adaptor cable. When connecting lines, connect the "Orange color line" of the adaptor cable to "RX -" of the RS-485 unit and the "White color line" of the adaptor cable to "RX +" of the RS-485 unit correctly.
| Adaptor cable | |
| No Description | |
| 1 | RS-485 + |
| 2 | RS-485 - |
| RS-485 Data Communication | |
| Description Color | |
| RS-485 + Green | |
| RS-485 - Blue | |
Connecting power source
Connect an AC 24 V power source to the power input jack. (Recommended power adaptor is AC 24 V/2 A or above.)
Protocol and baud rate settings
The camera has one 8-bit DIP switch block that determines the protocol and baud rate of the data communication. Settings are loaded when the camera boots up. Be sure to turn the camera off, change the DIP switch settings, and then power the camera back up to load the changes.
- Turn off the camera.
- Remove the dome cover.
- Remove the camera assembly cover.

- Set the DIP switches.
DIP switch locations
- Assemble the dome cover and the camera assembly cover in the reverse order.
- Power up the camera to load the changes.
Baud Rate setting

| DIP switch position | BAUD RATE(BPS) | |||
| SW1 SW2 SW3 SW4 | ||||
| OFF OFF OFF OFF 9 600 | ||||
| OFF OFF OFF ON 2 400 | ||||
| OFF OFF ON OFF 4 800 | ||||
| OFF ON OFF OFF 19 200 | ||||
| ON OFF OFF OFF 38 400 | ||||
| ON ON ON ON OSD Set | ||||
Protocol setting

| DIP switch position | Protocol | |||
| SW5 SW6 SW7 SW8 | ||||
| OFF OFF OFF OFF LG Multix | ||||
| OFF | ON | OFF OFF | Pelco C | |
| OFF OFF OFF | ON | Pelco D | ||
| OFF OFF ON | OFF | Pelco P | ||
| ON | ON | ON | ON | OSD Set |
Note
If you are not using the controller with LG Multix protocol, there may be some limitation of function control.
Camera ID Setting
The camera's ID is set to "0" as factory default. If you use two or more cameras simultaneously, change the ID of the cameras.
Set the camera ID setting referring to the pictures and the table below.

Removing the Protection Tape
You should remove the protection tape before installing the camera.
Remove the protection tape carefully.
For LCP2850-AN/AP models.
- Loosen the screws using the wrench and remove the dome cover.
- Remove the protection tape and attach the dome cover.
For LCP2850I-AN/AP models.
- Press the Dome Cover open button and then disassemble the dome cover by using ALIGN mark.
- Remove the protection tape and attach the dome cover.
Caution
You must align the OPEN and LOCK mark correctly when you turn the dome cover to open or close. If you do not align the mark, it causes a malfunction.
Mounting the camera
You can mount the camera on the ceiling or wall.
Surface mount (optional)
Follow the instructions below to surface mount the camera.
Caution
The building structure must be able to support 8 kg.
- Use the installation guide template to check the mounting location. Face the front of the label toward the area of interest.

- Install the surface mounting bracket on the ceiling.

- Assemble the camera and the surface mounting bracket by following step 1 and 2. Align the locking point of the surface mounting bracket and the camera.

- Tighten the locking screw.

- Connect the cables to the cable jacks of the camera body. After installing the camera, you should arrange the cables using the outlet box to protect the cables.

Ceiling mount (optional)
Follow the instructions below to mount the camera on the ceiling.
Caution
The building structure must be able to support 8 kg.
- Make a hole through the ceiling as shown below.

- Fasten the safety cable to the building superstructure. The building superstructure can vary depending on your installation environment.

- Install the ceiling mounting bracket on the ceiling. Face the front of the ceiling mounting bracket toward the area of interest.

- Tighten the screws until the ceiling mounting bracket holds the ceiling firmly.

- Pass the connection cable through the inner side of the ceiling. Connect the cables to the cable jacks of the camera body.

- Assemble the camera and ceiling mounting bracket by following steps 1 and 2. Align the locking point of the surface mounting bracket and the camera.

- Tighten the locking screw.

- Connect the cables to the cable jacks of the camera body. After installing the camera, you should arrange the cables using the outlet box to protect the cables.

Wall mount (optional)
Install the camera in the following order.
- Disassemble the PIPE Installation Bracket to remove the [A] part.
![[A]](/content/2026/06/1405182/images/e02fb6d7dd1b5e3f4171fd61cd1ce758d6feb3f010789b8655e0f90654490336.jpg)
- Install the PIPE Installation Bracket to the Wall Mount assembly.

Caution
Do not expose the connected part of the camera cable jacks in the rain or moisture.
Check the red stripe on one side of the safety cable.
- Drill a hole on the wall where you want to install the pipe. Pass the connection cable through the wall mount assembly so that they hang down.

- Install the wall mount assembly.

- Connect the connection cable and the safety cable to the camera body.

- Attach the camera to the camera assembly bracket by following steps 1 and 2. Align the locking point of the wall mount assembly and the camera.

- Tighten the locking screw.

- Assemble the camera cover as shown below.
![graph TD A["Circular Component"] --> B["Arrow Down"] B --> C["Circular Component with Internal Control Logic"] C --> D["Arrow Up"] D --> E["Vertical Mount"] style A fill:#f9f,stroke:#333 style E fill:#bbf,stroke:#333](/content/2026/06/1405182/images/7d65aaf3172437f05f08cb2179a06c3e2ab0f7a77ace6e33b39745a293b6daf7.jpg)

Note
You can install the PIPE Installation Bracket directly to the other type of LG Wall Mount assembly. This LG Wall Mount assembly makes it easy to install your camera.

Pendant mount (Optional)
Install the camera in the following order.
- Disassemble the PIPE Installation Bracket to remove the [A] part.
![[A]](/content/2026/06/1405182/images/414cee4d4efcee9ecae8482fa23dc19d71c8a160f34217bcfcdd813054ffa712.jpg)
- Install the PIPE Installation Bracket to the Pendant Mount assembly.

- Drill a hole on the wall where you want to install the pipe. Pass the connection cable through the pendant mount assembly so that they hang down.

- Install the pendant mount assembly.

- Connect the connection cable and the safety cable to the camera body.

- Attach the camera to the camera assembly bracket by following steps 1 and 2. Align the locking point of the wall mount assembly and the camera.

- Tighten the locking screw.

- Assemble the camera cover as shown below.
![graph TD A["Sensor Input"] --> B["Signal Path"] B --> C["Output Signal"]](/content/2026/06/1405182/images/a181dbc8621994841eebcdf050223e43725015cac013a859c151e2a460e3179e.jpg)
Note
You can install the PIPE Installation Bracket directly to the other type of LG Wall Mount assembly. This LG Wall Mount assembly makes it easy to install your camera.

4
Operation
Setup Menu Overview
The following table shows the list of menu items and options. You can adapt the camera to your requirements by setting up the respective items in these menus.
| 1st level 2nd level 3rd level Contents | |||
| CAMERA SET | FOCUS FOCUS MODE | AUTO/MANUAL/ONE PUSH/ZOOM TRIG | |
| FOCUS DIST | 1 M, 3 M, 6 M | ||
| ZOOM START x1 to x27 | |||
| ZOOM END x2 to x336 | |||
| RETURN - | |||
| EXPOSURE IRIS | AUTO/MANUAL | ||
| AGC OFF, 1 to 10 | |||
| WDR/BLC | OFF/WDR/BLC/HSBLC | ||
| BRIGHTNESS | 0 to 100 | ||
| SHUTTER | OFF, A.FLK, 1/160, ..., X2, AUTO | ||
| SENS-UP | AUTO X2/AUTO X3/.../AUTO X128/OFF | ||
| RETURN | - | ||
| WHITE BALANCE | ATW | - | |
| AUTO | - | ||
| MANUAL | COLOR TEMP | ||
| RED | |||
| BLUE | |||
| RETURN | |||
| ONE PUSH | - | ||
| CAMERA SET | DAY/NIGHT AUTO D/N | LEVEL LOW/MIDDLE/ | HIGH | |
| DWELL TIME 5,10,15,30,60 SEC | ||||
| RETURN - | ||||
| DAY - | ||||
| NIGHT - | ||||
| 3D-DNR OFF - | ||||
| LOW - | ||||
| MIDDLE - | ||||
| HIGH | - | |||
| COLOR | ON | COLOR | -50 to 50 | |
| OFF - | ||||
| SHARPNESS | 0 to 68 | - | ||
| STABILIZER | ON | - | ||
| OFF - | ||||
| RETURN | - | |||
| PAN/TILT SET | PRESET | SET PRESET | NAME | OFF/ON |
| SPEED | 1 to 127 | |||
| DWELL TIME | 1 to 255 | |||
| IRIS | AUTO, 20, 40, 60, 80, 100 % | |||
| WDR/BLC/HSBLC | OFF/ LOW WDR/ MID. WDR HIGH WDR/ LOW BLC/ MID. BLC / HIGH BLC/ LOW HSBLC / MID. HSBLC/ HIGH HSBLC | |||
| SHUTTER | X512, ..., x2, AUTO, OFF, A.FLK, 1/160, ..., 1/120 000 | |||
| SET POSITION | - | |||
| SAVE | - | |||
| RETURN - | ||||
| GOTO PRESET | 0 to 255 | |||
| PRESET TOUR | - | |||
| CLEAR PRESET | 0 to 255 | |||
| CLEAR ALL | - | |||
| FREEZE | ON | |||
| OFF | ||||
| RETURN - | ||||
| PAN/TILT SET GROUP TOUR SET GROUP | GROUP 1 to 10 | |||
| RUN 1 to 10 | ||||
| CLEAR 1 to 10 | ||||
| RETURN - | ||||
| PATTERN RECORD | 1 to 4 | |||
| RUN 1 to 4 | ||||
| RETURN - | ||||
| AUTO PAN SET AUTO PAN 1 to 8 | ||||
| RUN - | ||||
| CLEAR - | ||||
| RETURN - | ||||
| PRIVACY MASK | MASK NUMBER | 1 to 8 | ||
| SET MASK | - | |||
| MASK STATE | ON/OFF | |||
| MASK COLOR | GRAY, WHITE, BLACK | |||
| WIDTH | 0 to 320 | |||
| HEIGHT | 0 to 240 | |||
| RETURN - | ||||
| SPECIAL | PROPORTIONAL PT | ON/OFF | ||
| COMPASS | ON/OFF | |||
| HOME POSITION | ON | SET | ||
| GO | ||||
| DWELL TIME(INFINITE to 100 MIN) | ||||
| RETURN | ||||
| OFF | - | |||
| AUTO RETURN | ON | RETURN TIME(1 MIN to 100 MIN) | ||
| OFF | - | |||
| TILT LIMIT | ON/OFF | |||
| MOTION DET | ON/OFF | SENSITIVITY(0 to 100) | ||
| PAN/TILT SET SPECIAL COMMUNICATION | ION | PROTOCOL | LG MULTIX/ PELCO C/PELCO D/ PELCO P | |
| BAUDRATE | 2 400/ 4 800/ 19 200/ 38 400/9 600 BPS | |||
| SAVE & EXIT - | ||||
| RETURN - | ||||
| OSD SET USER TITLE ON/OFF - | ||||
| ZOOM MAG ON/OFF - | ||||
| FUNCTION ON/OFF - | ||||
| DOME ID ON/OFF - | ||||
| RETURN - | ||||
| LANGUAGE The option depends on the model. | ||||
| ALARM SET ALARM IN1 toALARM IN4 | ON NORMAL OPEN/CLOSE | |||
| ALARM IN1 to ALARM IN4 PRESET 0 to 255 | ||||
| DWELL TIME 3 to 255 | ||||
| RETURN - | ||||
| OFF | - | |||
| ALARM OUT1 toALARM OUT2 | ON | ALARM OUT1 to ALARM OUT2 ALARM IN1 to ALARM IN4,MOTION DET | ||
| DWELL TIME 3 to 255 | ||||
| RETURN - | ||||
| OFF | - | |||
| RESET | INFORMATION | - | ||
| INITIALIZATION | - | |||
| CAMERA RESET | - | |||
| FACTORY RESET | - | |||
| RETURN - | ||||
| RETURN | - | |||
Menu navigation
We use the LKD1000 controller in this manual to explain the features of the LG Dome camera because of the LKD1000's ability to control all of the LG Dome camera's advanced features. (For detailed controller instructions, refer to the LKD1000 Controller Manual.)
| LKD1000 button Camera OSD operation | |
| Cam OSD button | Displays or removes the setup menu. |
| ZOOM IN button | Use to move upper direction on the menu screen. |
| ZOOM OUT button | Use to move lower direction on the menu screen. |
| FOCUS NEAR button | Use for increase the value of the option. |
| FOCUS FAR button | Use for decrease the value of the option. |
| Open/Close(Enter) buttons | Executes selections and displays a submenu for an item with the mark. |
Accessing the camera setup menu
To access the setup menus using the keys on a LKD1000 controller, do the following:
- Select CAM (Camera) icon in the main menu and then press ENTER. The camera ID input menu will be displayed.
![graph TD A["CAM"] --> B["Please Enter Camer ID\nTarget CAM ID : _"]](/content/2026/06/1405182/images/43b8835874ff711267fd3cf8add66c99aab0204d4d22ac7139aa9f06e0430263.jpg)
- Enter the connected camera ID to control the camera connected to the LKD1000 controller directly and then press ENTER. The camera control menu will be displayed.

- Press [Cam OSD] button to display the camera setup menu.
At this point, you have access to the camera setup menu.
General operation
- Use [In] or [Out] button to select an option then press [Open] or [Close] button. Submenu appears on the monitor.
- Use [In] or [Out] button to select a submenu option.
- Use [Near] or [Far] button to select a value.
- Select [RETURN] option then press [Open] or [Close] to return to the previous menu.
- Press [Cam OSD] button to exit the setup menu.
Camera menu settings
Focus setting
The camera adjusts the focus automatically by sensing the center of the picture.
![[CAMERA SET MENU] ►FOCUS EXPOSURE WHITE BALANCE AUTO DAY/NIGHT AUTO 3D-DNR MIDDLE COLOR ON SHARPNESS 34(0~68) STABILIZER OFF RETURN ↓ [FOCUS MENU] ►FOCUS MODE ZOOM TRIG FOCUS DIST 1M ZOOM START X1 ZOOM END X336 RETURN](/content/2026/06/1405182/images/e734324dc724298dca614b2bf1b2256121aabe8131220628d0fc01e7b91dce4e.jpg)
Focus mode
Select [FOCUS MODE] option on the [FOCUS] menu, then select the following mode.
• AUTO: Auto-focus is activated automatically. - MANUAL: Focus is activated automatically after the zoom movement is finished. If you want to control the focus manually, press the FOCUS (NEAR or FAR) buttons on the controller. - ONE PUSH: The focus is activated manually. If the camera is received auto-focus command, the camera is activated auto-focus mode and the focus is set automatically and then the focus mode is automatically changed to manual mode. • ZOOM TRIG: The focus is activated manually. If you change the zoom, the focus is activated automatically and then the focus mode is automatically changed to manual mode.
Focus Distance setting
Selects the minimum shooting distance for the focus. Select [FOCUS DIST] option on the [FOCUS] menu, then select a focus distance value.
Zoom Start setting
You can set the zoom start position of the camera. When the zoom function is operated, the zoom always will start at the selected zoom start position. Select [ZOOM START] option on the [FOCUS] menu, then set a zoom start position.
Zoom End setting
You can set the zoom end position of the camera. If you set the zoom end position, the zoom is operated up to the selected zoom end position.
Select [ZOOM END] option on the [FOCUS] menu, then set the zoom end position.
Exposure settings![[CAMERA SET MENU] FOCUS ►EXPOSURE WHITE BALANCE AUTO DAY/NIGHT AUTO 3D-DNR MIDDLE COLOR ON SHARPNESS 34(0~68) STABILIZER OFF RETURN ↓ [EXPOSURE MENU] ►IRIS AUTO AGC 5 WDR/BLC OFF BRIGHTNESS 50 (0~100) SHUTTER AUTO SENS-UP OFF RETURN ↓](/content/2026/06/1405182/images/8d75e49540daaa7eb5307f2d5dd9b2aeac284d445093c5830a149a0e61d9a66f.jpg)
Iris setting
Select the desired lens iris value for camera exposure. Select [IRIS] option on the [EXPOSURE] menu, then select a value.
• AUTO: The lens iris is set automatically. - MANUAL: Use [Near] or [Far] button to select the DC Iris level. DC Iris level is set by one parameter unit.
AGC (Automatic Gain Control) setting
If the images are too dark, change the maximum [AGC] value to make the images bright.
- Select [AGC] option on the [EXPOSURE] menu.
- Use [Near] or [Far] button to select a mode.
WDR/BLC setting
Use WDR/BLC option to set the options for BLC or WDR camera.
- Select [WDR/BLC] option on the [EXPOSURE] menu.
- Use [Near] or [Far] button to select a mode then press [Open] or [Close].
- WDR LEVEL: WDR (Wide dynamic range) feature can be very helpful to cope with very challenging lighting conditions. It is capable of capturing both of the dark part and bright part and combining the differences into a scene to generate a highly realistic image as original scene. Set the WDR level (LOW, MIDDLE, HIGH).
- BLC LEVEL: Camera's backlight compensation feature helps alleviate issues of visibility in high contrast areas. Set the BLC level (LOW, MIDDLE, HIGH). • HSBLC: Use for masking brightness of the specific area to view the subject more clearly.
- HSBLC LEVEL: Select the HSBLC level. (LOW, MIDDLE, HIGH)
- COLOR: Use [Near] or [Far] button to select a color.
• OFF: Not used.
BRIGHTNESS setting
You can increase the brightness of the darkened video. If you set the brightness to a lower value, the image is darkened. If you set the brightness to a higher value, the image gets bright.
- Select [BRIGHTNESS] option on the [EXPOSURE] menu.
- Use [Near] or [Far] button to set the bright level.
SHUTTER (Shutter Speed) setting
Select the desired shutter speed for camera exposure. You can change the shutter speed to a higher speed to capture fast-moving subjects, though the image becomes darker.
- Select [SHUTTER] option on the [EXPOSURE] menu.
- Use [Near] or [Far] button to set shutter speed.
SENS-UP setting
If pictures are not clear due to darkness, use this function to increase the sensitivity of the picture.
- Select [SENS-UP] option on the [EXPOSURE] menu.
- Use [Near] or [Far] button to set the SENS-UP limit. To set the SENS-UP function, select [AUTO] on the [SHUTTER].
Note
If you set the AGC to [OFF] or the SHUTTER is set to one of the SHUTTER options except AUTO on the [EXPOSURE] menu, the [SENS-UP] setting is not available and [---] mark is displayed.
White Balance setting
Select the method by which the camera shifts its output colors to compensate for the color of a light source.
![[CAMERA SET MENU] FOCUS EXPOSURE WHITE BALANCE AUTO DAY/NIGHT AUTO 3D-DNR MIDDLE COLOR ON SHARPNESS 34(0~68) STABILIZER OFF RETURN](/content/2026/06/1405182/images/7c869f1535280c8110bc280ae25574755df4c9883847e06e1a884c76ce2f58ed.jpg)
- Select [WHITE BALANCE] option on the [CAMERA SET] menu.
- Use [Near] or [Far] button to select a mode then press [Open] or [Close].
- ATW (Auto-Tracing White Balance): In this mode, the color temperature range for the proper white balance is approximately from 1,700 K to 11,000 K. Proper white balance may not be obtained under the following conditions:
- When the color temperature is out of the 1,700 K to 11,000 K range.
- When the scene mostly contains high color temperature objects, such as a blue sky or sunset.
- When the scene is dim.
- AUTO: In this mode, the color temperature range for the proper white balance is approximately 3,500 K to 6,500 K. Proper white balance may not be obtained under the following conditions:
- When the color temperature is out of the 3,500 K to 6,500 K range.
- When the scene mostly contains high color temperature objects, such as a blue sky or sunset.
- When the scene is dim.
• MANUAL: You can set the white balance options manually.
- COLOR TEMP: Use the [Near] or [Far] button to select a function.
INDOOR: The color temperature range for proper white balance is approximately 3600 K. OUTDOOR: The color temperature range for proper white balance is approximately 6,500 K.
- RED: Set the desired red value. (-100 to 100)
- BLUE: Set the desired blue value. (-100 to 100)
• ONE PUSH: If you select the ONE PUSH mode, you will be able to set up the White Balance automatically using the [Open] or [Close] button.
Day/Night setting
![[CAMERA SET MENU] FOCUS EXPOSURE WHITE BALANCE AUTO DAY/NIGHT AUTO 3D-DNR MIDDLE COLOR ON SHARPNESS 34(0~68) STABILIZER OFF RETURN](/content/2026/06/1405182/images/47c66ae61e3392e389da7ccf071854797fabd40709ade8d9fdb80ff9ed533061.jpg)
- Select the [DAY/NIGHT] option on the [CAMERA SET] menu.
- Use the [Near] or [Far] button to select the mode.
• AUTO: You will be able to change the Day/Night mode automatically.
- D/N LEVEL: Use the [Near] or [Far] button to select a level.
- DWELL TIME: Use the [Near] or [Far] button to select a dwell time.
Note
If you set the AGC to [OFF] or the SHUTTER is set to one of the SHUTTER options except AUTO on the [EXPOSURE] menu, the AUTO mode of the DAY/NIGHT function is not available and [---] mark is displayed.
• DAY: Color mode enabled. • NIGHT: Black-and-white mode enabled.
3D-DNR setting
![[CAMERA SET MENU] FOCUS EXPOSURE WHITE BALANCE AUTO DAY/NIGHT AUTO ►3D-DNR MIDDLE COLOR ON SHARPNESS 34(0~68) STABILIZER OFF RETURN](/content/2026/06/1405182/images/1d05a6f80f0ae1185e731de64a6b4b2ae52aebd618e0bc67bff0987012dee309.jpg)
- Select [3D-DNR] option. If pictures are not clear due to brightness, use this function to reduce the noise of picture.
- Use [Near] or [Far] button to select a option.
! Note
• If you set the AGC to [OFF] on the [EXPOSURE] menu, the [3D-DNR] function is not available. - When you use this function, the afterimage may occur.
Color setting
You can switch the displayed picture to grayscale or color.
![[CAMERA SET MENU] FOCUS EXPOSURE WHITE BALANCE AUTO DAY/NIGHT AUTO 3D-DNR MIDDLE COLOR ON SHARPNESS 34(0~68) STABILIZER OFF RETURN](/content/2026/06/1405182/images/3f40c81e7fbcea4b1701dac6b0d3cd7544e02a1fb9f401d042ee01c2a4cb3d0b.jpg)
- Select [COLOR] option on the [CAMERA SET] menu.
- Use [Near] or [Far] button to change a color effect.
- ON: To display the picture with color. Select ON and press [Open] or [Close] to display the submenu. You can adjust the color level using the [Near] or [Far] button.
• OFF: To display the picture with grayscale.
Sharpness setting
Sharpens the image outline.
![[CAMERA SET MENU] FOCUS EXPOSURE WHITE BALANCE AUTO DAY/NIGHT AUTO 3D-DNR MIDDLE COLOR ON SHARPNESS 34(0~68) STABILIZER OFF RETURN](/content/2026/06/1405182/images/907db77186624dff7fa8824f4f0130f581f7d70c290ab77636e6655e600b3f9d.jpg)
- Select [SHARPNESS] option on the [CAMERA SET] menu.
- Use [Near] or [Far] button to adjust the option. If you set the sharpness value to higher, the image outline becomes sharp. If you set to lower value, the image outline becomes dim.
Stabilizer setting
The image stabilizer function minimizes the appearance of shaky images caused by low-frequency vibration. This function is useful for outdoor surveillance.
![[CAMERA SET MENU] FOCUS EXPOSURE WHITE BALANCE AUTO DAY/NIGHT AUTO 3D-DNR MIDDLE COLOR ON SHARPNESS 34(0~68) STABILIZER OFF RETURN](/content/2026/06/1405182/images/c6e487650e296cfda78f59fa85784391485ffa185ce365955b0898915eead733.jpg)
- Select [STABILIZER] option on the [CAMERA SET] menu.
- Use [Near] or [Far] button to set it [ON] or [OFF].
PAN/TILT Settings
Preset setting
Preset position is the function to register camera monitoring positions (preset positions) associated with position numbers. By entering the position numbers, you can move cameras to the preset positions.
![[MENU] CAMERA SET ▶PAN/TILT SET OSD SET LANGUAGE ENG ALARM SET RESET RETURN](/content/2026/06/1405182/images/fe7bd5e29654657b939a8d062df9d05b2c4a859adb0832bd5f0fd3b21c1f501d.jpg)

![[PAN/TILT MENU] ▶PRESET GROUP TOUR PATTERN AUTO PAN PRIVACY MASK SPECIAL RETURN](/content/2026/06/1405182/images/8bdb5529751626a00794b18f1907c0d13a8623b033f87cd25f5417b10d51bab2.jpg)
To register preset positions
- Select the [SET PRESET] option on the [PRESET] menu.
- Use the [Near] or [Far] button to select the preset number you wish to register and press the [Open] or [Close] button.
- Set the preset name.
How to set the preset name.
- Set the NAME option to [ON] and press [Open] or [Close] button.
- Use [In], [Out], [Near] or [Far] button to select a character, number, symbol mark or option item. • </>: Moves cursor to left or right. • (Blank): Insert a space at the cursor position.
- CLR: If you enter the wrong code, select [CLR] then press [Open] or [Close] to delete. All letters will be erased at once. • SAVE: Select this option to confirm the settings.
- EXIT: Select this option to exit the settings.
- Press [Open] or [Close] button to confirm your selection.
- Select the speed to move to the preset position.
- Select the preset tour dwell time.
- Set the IRIS option. IRIS LEVEL are set by 20 % unit (20%, 40%, 60%, 80%, 100%)
- Set the WDR/BLC/HSBLC option.
- Set the SHUTTER option.
- Select the [SET POSITION] option and press the [Open] or [Close] button.
- Move the camera to a point you wish by using the joystick and then press the [Open] or [Close] button to save it.
- Select the [SAVE] option and press the [Open] or [Close] button to confirm the settings. The position and its number are memorized.
- Repeat steps 1 to 11 to add additional positions.
- Select the [RETURN] option and press the [Open] or [Close] button to exit the setting menu.
Changing a picture in a preset position
The preset function makes the combination camera move to the programmed preset position. It is necessary to program preset positions for the combination camera beforehand.
- Select the [GOTO PRESET] option on the [PRESET] menu.
- Select the memorized preset position's index number then press [Open] or [Close] button. The camera moves to the preset position and the picture of the camera in that position appears on the monitor.
To tour the preset positions
You can tour all preset positions.
- Select [PRESET TOUR] option on the [PRESET] menu. All registered preset positions in the camera will be selected and the camera position image will be switched on the active monitor.
- You can stop the tour by moving the joystick or sending Stop Tour commands.
To clear the preset position
You can clear a memorized preset position.
- Select [CLEAR PRESET] option on the [PRESET] menu.
- Selects the memorized preset index number then press [Open] or [Close] button to clear the preset positions.
To clear all the preset positions
You can clear all of the memorized preset positions at once.
- Select [CLEAR ALL] option on the [PRESET] menu.
- Press [Open] or [Close] button to clear all preset positions.
Freeze function
- Select [FREEZE] option on the [PRESET] menu.
- Use [Near] or [Far] button to set [ON] or [OFF].
Group tour setting
You can create a group using preset positions that are already registered. A maximum of 10 groups is available.
![[PAN/TILT MENU] PRESET GROUP TOUR PATTERN AUTO PAN PRIVACY MASK SPECIAL RETURN [GROUP TOUR MENU] SET GROUP 1 RUN 1 CLEAR 1 RETURN](/content/2026/06/1405182/images/bf5d3f40b6649158ab98ae5d645f3ef77f71706ab9074a123953c51c4cfb9d9f.jpg)
To set the group
- Select [SET GROUP] option on the [GROUP TOUR] menu.
- Select the group number and press [Open] or [Close] button.
- Set the group item. You can set up to 8 group items.
- Select [SAVE] option and press [Open] or [Close] button to confirm the settings.
- Select [RETURN] option and press [Open] or [Close] button to exit the setting menu.
To tour the group
You can tour the group that is registered already.
- Select [RUN] option on the [GROUP TOUR] menu.
- Select the group number and press [Open] or [Close] button. The camera moves to the preset position in the group and the picture of the camera in that position appears on the monitor.
To delete a group
You can delete a memorized group.
- Select [CLEAR] option on the [GROUP TOUR] menu.
- Select the group number and press [Open] or [Close] button. The group will be deleted.
Pattern setting
You can activate the camera in a repeating pattern. The pattern is programmed by recording your manual pan, tilt, and zoom operations. The camera stores the movements you performed in memory.
![[PAN/TILT MENU] PRESET GROUP TOUR ■PATTERN AUTO PAN PRIVACY MASK SPECIAL RETURN [PATTERN MENU] ■RECORD 1 RUN 1 RETURN](/content/2026/06/1405182/images/fd3f2cf0dbae3b0158cf079f7bccc4ba905939a22510fb73548f309209c39729.jpg)
To record the pattern
- Select [RECORD] option on the [PATTERN] menu.
- Select the recording number and press [Open] or [Close] button. The pattern recording is started.
- Move the camera through the desired movement.
- Press [Open] or [Close] button to stop the pattern recording.
Note
The available total time of pattern differs depending on operation.
To play the pattern
- Select [RUN] option on the [PATTERN] menu.
- Select the recording number and then press [Open] or [Close] button to play the programmed pattern. The tour will play indefinitely until you stop it by moving the joystick or pressing any button.
Auto Pan setting
By selecting the Auto Pan number, the camera pans automatically.
![[PAN/TILT MENU] PRESET GROUP TOUR PATTERN AUTO PAN PRIVACY MASK SPECIAL RETURN [AUTO PAN MENU] SET AUTO PAN 1 RUN CLEAR RETURN](/content/2026/06/1405182/images/4b9c5e89a94c6ecfc2ae72ec9a37eb64af33b2a5377055c593d5131e82474273.jpg)
To set the Auto Pan position
- Select [SET AUTO PAN] option on the [AUTO PAN] menu.
- Select the number you wish to register and press [Open] or [Close] button.
- Select the moving speed.
- Select the Auto pan dwell time.
- Move the camera to the desired start point by using the joystick.
- Select the [SET POSITION] option and press [Open] or [Close] button.
- Move the camera to the desired end point by using the joystick and then press [Open] or [Close] button.
- Repeat steps 1 to 7 to add additional positions.
- Select [RETURN] option and press [Open] or [Close] button to exit the setting menu.
Note
If you press the [CLEAR] option during the auto panning, all of the AUTO PAN positions will be deleted.
To play the auto pan
You can play the camera with the auto pan function.
- Select [RUN] option on the [AUTO PAN] menu.
- You can stop the auto pan function by moving the joystick or pressing any button.
To delete the auto pan position
You can delete the memorized auto pan position.
- Select [AUTO PAN] option on the [PAN/TILT] menu.
- Select [CLEAR] option then press [Open] or [Close] button to delete the auto pan position.
Privacy Mask setting
This function is aimed at protecting personal privacy; the masked area is not displayed on the screen. Up to 8 zones can be registered.
![[PAN/TILT MENU] PRESET GROUP TOUR PATTERN AUTO PAN ▶PRIVACY MASK SPECIAL RETURN [PRIVACY MASK MENU] ▶MASK NUMBER 1 SET MASK MASK STATE ON MASK COLOR BLACK WIDTH 320(0~320) HEIGHT 240(0~240) RETURN](/content/2026/06/1405182/images/42ba8dd38918b1b9e2b110217ab16da3d1c788e424843f954adecb0f5464cd5a.jpg)
- Select the [PRIVACY MASK] option on the [PAN/TILT MENU].
- Press the [Open] or [Close] button to display the PRIVACY MASK MENU.
- Use the [Near] or [Far] button to select a zone number on the [MASK NUMBER] option.
- Select the [SET MASK] option and press the [Open] or [Close] button.
- Select the mask zone using the joystick and then press the [Open] or [Close] button to save it.
- Use the [Near] or [Far] button to set the [ON] or [OFF] on the [MASK STATE] option. If you have already registered the mask zone and set it to ON, the mask zone box appears on the monitor.
- Use the [Near] or [Far] button to select the color of the mask zone box on the [MASK COLOR] option.
- Select the [WIDTH] option and use the [Near] or [Far] button to adjust the horizontal size of the mask zone box.
- Select the [HEIGHT] option and use the [Near] or [Far] button to adjust the vertical size of the mask zone box.
- Repeat steps 3 to 9 to add additional positions.
Note
- The parts with the registered mask numbers from 1 to 4 have the same color. (So do the parts with the numbers from 5 to 8). If you change the mask color, the registered mask color will be changed automatically with the same color for each group (1 to 4, 5 to 8).
- The initial PRIVACY MASK color is set to blue. After setting the PRIVACY MASK position on the [SET MASK] option, it will be changed to gray color. Be sure to press the [Open] or [Close] button on the [SET MASK] option to confirm the privacy mask color. • If you need a Privacy Mask for a Preset, set the Privacy Mask first.
Special setting![[PAN/TILT MENU] PRESET GROUP TOUR PATTERN AUTO PAN PRIVACY MASK SPECIAL RETURN [SPECIAL MENU] PROPORTIONAL PT ON COMPASS OFF HOME POSITION OFF AUTO RETURN OFF TILT LIMIT ON MOTION DET OFF COMMUNICATION RETURN](/content/2026/06/1405182/images/c6f69589b84e77373ada3480e9b37ec5039233fe99ea3731f5fe543e26332d04.jpg)
Proportional PT
This function optimizes the image by automatically adjusting the PAN/TILT (horizontal/vertical rotation) speed according to the zoom ratio.
- Select [PROPORTIONAL PT] option on the [SPECIAL] menu.
- Use [Near] or [Far] button to toggle it on and off.
• ON : Pan/tilt speed is in inverse proportion to the zoom ratio. • OFF : The speed is constant at the fastest level regardless of the zoom ratio.
Compass
You can display the north, south, east and west information on the screen.
- Select [COMPASS] option on the [SPECIAL] menu.
- Set the [COMPASS] option to [SET] and then press [Open] or [Close] button.
- Select north point using the joystick and then press [Open] or [Close] button.
- Set the [COMPASS] option to [ON].
Home position
The home position is the camera's basic position.
The camera returns to this position whenever you want.
Use the following procedure to make the home position.
- Select [HOME POSITION] option on the [SPECIAL] menu.
- Use [Near] or [Far] button to set it ON.
- Press [Open] or [Close] button.
- Select [SET] option and then press [Open] or [Close] button.
- Select the home position where you want and then press [Open] or [Close] button.
- Select [DWELL TIME] option and then select the dwell time.
- Select [RETURN] option and press [Open] or [Close] button to exit the setting menu.
Go to Home position
- Select [HOME POSITION] option on the [SPECIAL] menu.
- Use [Near] or [Far] button to set it ON.
- Press [Open] or [Close] button.
- Select [GO] option and then press [Open] or [Close] button. The camera will move to the home position.
Note
If you do not want to use the home position function, set the [HOME POSITION] option to [OFF].
Auto return
This function can be used to specify automatic return to a particular mode if a certain amount of time elapses without any operation being performed.
- Select [AUTO RETURN] option on the [SPECIAL] menu.
- Use [Near] or [Far] button to set it [ON] and then press [Open] or [Close] button.
- Select [RETURN TIME] option and then select the auto return time.
- Select [RETURN] option and press [Open] or [Close] button to exit the setting menu.
Tilt limit
You can specify the tilt range. If you set this function, the camera is able to tilt from 10° to 170° .
- Select [TILT LIMIT] option on the [SPECIAL] menu.
- Use [Near] or [Far] button to set it [ON]. If you do not want to use this function, set it to [OFF].
! Note
The top side of screen may be hidden by tilting range.
Motion Detection
The motion detection detects the moving objects in the scene by monitoring changes in brightness level.
- Select [MOTION DET] option on the [SPECIAL] menu.
- Use [Near] or [Far] button to set it [ON]. If you do not want to use this function, set it to [OFF].
- Press [Open] or [Close] button.
- Use [Near] or [Far] button to set the [SENSITIVITY] option.
Communication
This setting is required to establish a connection between the system controller and the camera.
- Select [COMMUNICATION] option on the [SPECIAL] menu.
- Press [Open] or [Close] button.
- Set the below options.
- Protocol: This item lets you set a protocol for RS-485 communication. Select the desired protocol.
- Baud Rate: Select the desired speed of communication between the system controller and the camera. Confirm selected parameter to the baud rate of the system controller.
- SAVE & EXIT: Select this option and then press [Open] or [Close] button to save the communication settings and exit the setting menu.
OSD Settings
![[MENU] CAMERA SET PAN/TILT SET ►OSD SET LANGUAGE ENG ALARM SET RESET RETURN [OSD MENU] ►USER TITLE OFF ZOOM MAG OFF FUNCTION OFF DOME ID OFF RETURN](/content/2026/06/1405182/images/343c42b0865243e00d1912332eb48e6884f68e93e199d9f955593137434c5ba5.jpg)
User title setting
You can use the camera identification to assign a number and character to the camera.
- Select [USER TITLE] option on the [OSD] menu.
- Use [Near] or [Far] button to set it [ON].
- Press [Open] or [Close] button. The USER TITLE menu appears.
- Use [In], [Out], [Near] or [Far] button to select a character, number, symbol mark or option item.
![[USER TITLE] ABCDEFGHIJKLMNOPQRSTUVWXYZ abcdefghijklmnopqrstuvwxyz - 0123456789 < > CLR POS EXIT [_](/content/2026/06/1405182/images/2d4efa819170cf1bb2af0d98e0d6a74a157ff71e33fdcb4fff93932e81bd5aef.jpg)
- </>: Moves cursor to left or right. • 1 (Blank): Insert a space at the cursor position.
- CLR: If you enter the wrong code, select [CLR] then press [Open] or [Close]. All letters will be erased at once.
- POS: Move the USER TITLE position on the screen using the [Near] or [Far] buttons. • END: Select this option to exit the settings.
ZOOM MAG setting
Displays or removes the zoom OSD on the screen.
![[OSD MENU] USER TITLE OFF ZOOM MAG OFF FUNCTION OFF DOME ID OFF RETURN ↕↓](/content/2026/06/1405182/images/d029a054562910b4409fafab47b366dae431f539005183df6dc95dd7bbdf0351.jpg)
- Select [ZOOM MAG] option on the [OSD] menu.
- Use [Near] or [Far] button to set it [ON] or [OFF].
- Select [RETURN] option and press [Open] or [Close] button to exit the setting menu.
FUNCTION setting
Displays or removes the Function OSD on the screen.
![[OSD MENU] USER TITLE OFF ZOOM MAG OFF FUNCTION OFF DOME ID OFF RETURN ↕](/content/2026/06/1405182/images/36d4eb53f259bdad2fc7a5fdec45b06cf0dc54cd209950d343a16fb4698257f0.jpg)
- Select [FUNCTION] option on the [OSD] menu.
- Use [Near] or [Far] button to set it [ON] or [OFF].
- Select [RETURN] option and press [Open] or [Close] button to exit the setting menu.
DOME ID setting
Displays or removes the Camera ID OSD on the screen.
![[OSD MENU] USER TITLE OFF ZOOM MAG OFF FUNCTION OFF ►DOME ID OFF RETURN ↕](/content/2026/06/1405182/images/77656e7161679949d810d8d50b0d740905f828b674f8cd453586005f68185902.jpg)
- Select [DOME ID] option on the [OSD] menu.
- Use [Near] or [Far] button to set it [ON] or [OFF].
- Select [RETURN] option and press [Open] or [Close] button to exit the setting menu.
LANGUAGE Setting
Select a language for the setup menu and OSD display.
![[MENU] CAMERA SET PAN/TILT SET OSD SET LANGUAGE ENG ALARM SET RESET RETURN](/content/2026/06/1405182/images/3c0a99fce03e12e09e3ef6a8d16727b4c5b71806d31af44760907b1285b5ab10.jpg)
ALARM Setting
This camera has a terminal that can sense the alarm signals. The camera can be programmed to go to a preset with a signal from any connected alarm device.
![[MENU] CAMERA SET PAN/TILT SET OSD SET LANGUAGE ENG ▶ALARM SET RESET RETURN](/content/2026/06/1405182/images/d753b75caa0e06b1b2c6455cf7a8daade6db7c10fbe33fb1faa4323590b92ce5.jpg)
![[ ALARM MENU ] ►ALARM IN1 OFF ALARM IN2 OFF ALARM IN3 OFF ALARM IN4 OFF ALARM OUT1 OFF ALARM OUT2 OFF RETURN ↕](/content/2026/06/1405182/images/e89e15a4261be27cdf51113112501ed43b0b133f53261d4821cd4344dfee1f27.jpg)
Alarm In setting
- Select one of the alarms in option on the [ALARM SET] menu.
- Use the [Near] or [Far] button to set it to [ON].
- Press the [Open] or [Close] button.
- Select the [NORMAL] option and then select the [Open] or [Close] option.
• OPEN: Activate the alarm in the close position. • CLOSE: Activate the alarm in the open position.
- Select the [ALARM IN(1 to 4)] option and select a preset number. When the alarm is triggered, the camera moves to the selected preset position. The presets run continuously until the alarm source is off.
- Select the [DWELL TIME] option and then set the alarm dwell time. The alarm is stopped after the selected dwell time.
Alarm Out setting
- Select one of the alarm out options on the [ALARM SET] menu.
- Use the [Near] or [Far] button to set it to [ON].
- Press the [Open] or [Close] button.
- Select an alarm input number or motion detection. When the selected alarm input is triggered or motion is detected, the alarm signal is outputted.
- Select the [DWELL TIME] option and then set the alarm dwell time. The alarm output is stopped after the selected dwell time.
RESET Setting
![[MENU] CAMERA SET PAN/TILT SET OSD SET LANGUAGE ENG ALARM SET ■RESET RETURN ↓ [RESET MENU] ■INFORMATION INITIALIZATION CAMERA RESET FACTORY RESET RETURN](/content/2026/06/1405182/images/94fede5d538ebb6730055ce9d1c6b5193302a48e05f9aae6e9d27b3d2e0cf093.jpg)
Information
You can view the current camera information such as PTZ software version, camera software version, camera ID, Protocol and Baud Rate.
- Select [INFORMATION] option on the [RESET] menu.
- Press [Open] or [Close] button to display the current camera information.
Initialization
You can initialize the camera settings.
- Select [INITIALIZATION] option on the [RESET] menu.
- Press [Open] or [Close] button then confirmation window is displayed.
- Select [YES] and press [Open] or [Close] button.
Camera reset
- Select [CAMERA RESET] option on the [RESET] menu.
- Press [Open] or [Close] button then confirmation window is displayed.
- Select [YES] and press [Open] or [Close] button.
Factory reset
Clear certain settings and information and return to factory default settings.
- Select the [FACTORY RESET] option on the [RESET] menu.
- Press the [Open] or [Close] button; a confirmation window is displayed.
- Select [YES] and press the [Open] or [Close] button. The camera will return to the factory default settings.
5
Appendix
Specifications
| Model LCP2850-AN LCP2850-AP LCP2850I-AN LCP2850I-AP | |||||
| Signal System NTSC PAL NTSC PAL | |||||
| Image Sensor 4.5 mm(1/4 Type) Super HAD II CCD | |||||
| Total Pixels Number 520 000 Pixels 610 000 Pixels 520 000 Pixels 610 000 Pixels | |||||
| Effective Pixels Number 490 000 Pixels 570 000 Pixels 490 000 Pixels 570 000 Pixels | |||||
| Horizontal Resolution 600 TV Lines | |||||
| Lens x28 Zoom, F1.5 (Wide End), F3.7(Tele End), f= 3.5 mm to 98 mm | |||||
| S/N Ratio 50 dB (AGC Off) | |||||
| Day/Night | AUTO / DAY / NIGHT | ||||
| Minimum Illumination (30 IRE) | B/W | 0.01 lx (Sens-up Off), 0.000 01 lx (Sens-up On) | |||
| Color | 0.2 lx (Sens-up Off), 0.003 lx (Sens-up On) | ||||
| Optical Zoom | x28 | ||||
| Digital Zoom | x12 | ||||
| Scanning Frequency (H/V) | 15.734 KHz / 59.94 Hz | 15.625 KHz / 50 Hz | 15.734 KHz / 59.94 Hz | 15.625 KHz / 50 Hz | |
| Sync System | Internal | ||||
| White Balance | ATW / AUTO / MANUAL / ONE PUSH | ||||
| Control method | RS-485, Coaxial | ||||
| Alarm Input | 4 Channel | ||||
| Alarm Output | 2 Channel | ||||
| Model LCP2850-AN LCP2850-AP LCP2850-I-AN LCP2850I-AP | |||
| Video Output 1 Vp-p Composite (75 Ω) | |||
| Backlight Compensation WDR / BLC / HSBLC / OFF | |||
| Electric Shutter 1/60 to 1/120 000 1/50 to 1/120 000 1/60 to 1/120 000 | 1/50 to 1/120 000 | ||
| 3D-DNR OFF / LOW / MIDDLE / HIGH | |||
| Auto Gain Control ON / OFF | |||
| Digital Effect Auto Flip | |||
| Pattern Recording & Play 1 to 4 / 1 to 4 | |||
| Protection Vandal Proof / IP66 | |||
| Sens-Up OFF / AUTO / MANUAL | |||
| Iris Control AUTO/MANUAL | |||
| Stabilizer (EIS) | ON / OFF | ||
| Motion Detection | Support | ||
| Panning Range & Speed | 0° to 360°, Maximum 500°/Second | ||
| Tilting Range & Speed | 0° to 180°, Maximum 500°/Second | ||
| Privacy Zone 8 Mask Zones | |||
| Preset/ID | 256 Position / 256 | ||
| Auto Panning | 2 to 8 points | ||
| Pattern | 4 | ||
| Group Touring | Maximum 10 Groups | ||
| Protocol | Coax : Pelco-C (Coaxitron)RS-485 : LG Multix, Pelco(D/P) | ||
| Operating Temperature/Humidity | -20 °C to 50 °C / 0 % RH to 80 % RH | -10 °C to 50 °C / 0 % RH to 80 % RH | |
| Safekeeping Temperature/Humidity | -30 °C to 60 °C / 0 % RH to 90 % RH | -30 °C to 60 °C / 0 % RH to 90 % RH | |
| Power Source | AC 24 V | ||
| Power Consumption / Input Current | 22 W / 1.5 A | 16 W / 1.1 A | |
| Dimension (∅ xH) | 234.6 mm x 269.9 mm | 205.8 mm x 247.4 mm | |
| Weight | 4.07 kg | 2.4 kg | |