Product TypeOnline Double Conversion UPS
BrandEaton
Model9SX3000G
Capacity (VA/W)3000 VA / 2700 W
TopologyOnline Double Conversion
Output WaveformPure Sine Wave
Input Voltage Range208-240 VAC
Output Voltage208/220/230/240 VAC
Frequency50/60 Hz (Auto Sensing)
Battery TypeSealed Lead-Acid (VRLA)
Battery Runtime (Full Load)Approx. 5 minutes
Dimensions (H x W x D)432 x 130 x 650 mm (17.0 x 5.1 x 25.6 in)
Weight45 kg (99 lbs)
Communication PortsUSB, RS-232, EPO (Emergency Power Off)
CertificationsUL, CSA, FCC
Warranty3 years
Operating Temperature0°C to 40°C (32°F to 104°F)
Audible Noise< 50 dBA at 1 meter
MaintenanceHot-swappable batteries, front panel status indicators
Safety FeaturesOverload, short circuit, overheat protection

Frequently Asked Questions - 9SX3000G EATON

How do I start the UPS for the first time?
Connect the battery pack, plug the UPS into a wall outlet, and press the power button. The UPS will perform a self-test and then output power.
What does the LED display show?
The LED display shows input/output voltage, load level, battery status, and alarm conditions. Refer to the manual for detailed explanations of each icon.
How often should I replace the batteries?
Under normal conditions, batteries should be replaced every 3-5 years. If runtime decreases significantly, consider replacement sooner.
Can I plug the UPS into a power strip?
No, plug the UPS directly into a wall outlet. Avoid using extension cords or power strips to prevent overloading and fire hazards.
How do I interpret the alarm sounds?
A continuous alarm indicates overload or fault. A beeping every few seconds means battery operation. Silence the alarm by pressing the alarm mute button if allowed.
What maintenance is required?
Periodically check the UPS for dust, ensure vents are clear, test runtime annually, and replace batteries as needed. No user maintenance of internal components other than batteries.
Can I connect a generator to the UPS?
Yes, but the generator must provide stable voltage and frequency. The UPS may switch to battery if the generator output is unstable. Use a generator with sufficient capacity.
How do I replace the battery?
Turn off the UPS and disconnect all loads. Remove the front bezel, slide out the battery tray, disconnect old battery, insert new battery, and reassemble. Refer to manual for detailed steps.
What does the overload indicator mean?
The overload indicator shows when the connected load exceeds the UPS capacity. Reduce the load immediately to prevent shutdown. The UPS will alarm and eventually shut off.
How do I update the firmware?
Firmware updates are done via the USB port using Eaton's software tools. Download the latest firmware from Eaton's website and follow the instructions in the software.

User questions about 9SX3000G EATON

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Inverter in PDF format for free! Find your manual 9SX3000G - EATON and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. 9SX3000G by EATON.

USER MANUAL 9SX3000G EATON

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : EATON

Model : 9SX3000G

Category : Inverter