| Product Type | Portable Appliance Tester (PAT) |
| Brand | Megger |
| Model | PAT120 |
| Category | Measuring Equipment |
| Dimensions (W x H x D) | 315 x 285 x 155 mm |
| Weight | 3.5 kg |
| Power Supply | 230 V AC, 50/60 Hz, 100 VA |
| Display | LCD with backlight |
| Insulation Resistance Test | 250 V / 500 V, up to 200 MΩ |
| Earth Continuity Test | 200 mA, 0.01 – 2 Ω |
| Polarity Test | 2 A, detects polarity reversal |
| Load Test | 10 A, up to 2.5 kVA |
| Leakage Current Test | 0.1 – 20 mA |
| Safety Rating | CAT II 300 V, IEC 61010 |
| Operating Temperature | 0 °C to 40 °C |
| Storage Temperature | -10 °C to 50 °C |
| Humidity Range | 20 % to 80 % non-condensing |
| Included Accessories | Test leads, mains cable, carry case |
| Optional Accessories | Remote probe, printer, software |
| Calibration Interval | 12 months |
| Warranty | 1 year |
| Languages | English, French, German, Spanish |
| Manual Type | PDF user manual (20 pages) |
Frequently Asked Questions - PAT120 Megger
How do I perform an insulation resistance test with the PAT120?
Connect the test leads to the appliance and select the insulation resistance function. Choose 250 V or 500 V test voltage, then press the test button. The result will be displayed in MΩ.
What is the maximum test voltage for insulation testing?
The PAT120 offers two insulation test voltages: 250 V and 500 V.
How can I replace the fuse in the PAT120?
Disconnect the device from the mains. Open the fuse holder on the side panel. Replace the blown fuse with one of the same rating (e.g., 1 A, 250 V). Close the holder securely.
What does error code E1 mean on the PAT120?
Error code E1 indicates a test lead connection issue. Check that the leads are securely connected and not damaged. Reconnect and try again.
Can the PAT120 test IT equipment?
Yes, but IT equipment may require a soft start or specific test sequence. Refer to the manual for guidance on testing sensitive electronics.
How to clean the Megger PAT120?
Use a dry, lint-free cloth to wipe the exterior. Do not use solvents or abrasive cleaners. Keep the test leads and connectors clean.
What is the weight of the PAT120?
The device weighs approximately 3.5 kg, making it portable for field use.
How do I update the firmware on the PAT120?
Firmware updates are done via the Megger software and a USB connection. Download the latest firmware from the Megger website and follow the update instructions.
Where can I find the serial number on the PAT120?
The serial number is located on the rear panel label near the power input. It is also found in the 'Settings' menu under 'Info'.
Is the PAT120 suitable for testing 3-phase appliances?
Yes, with the appropriate adapter (optional). The PAT120 can test 3-phase appliances by sequentially testing each phase against neutral and earth.