Megger

PAT120 - Measuring equipment Megger - Free user manual and instructions

Find the device manual for free PAT120 Megger in PDF.

📄 20 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Megger PAT120 - page 3
Pick your language and provide your email: we'll send you a specifically translated version.
Product TypePortable Appliance Tester (PAT)
BrandMegger
ModelPAT120
CategoryMeasuring Equipment
Dimensions (W x H x D)315 x 285 x 155 mm
Weight3.5 kg
Power Supply230 V AC, 50/60 Hz, 100 VA
DisplayLCD with backlight
Insulation Resistance Test250 V / 500 V, up to 200 MΩ
Earth Continuity Test200 mA, 0.01 – 2 Ω
Polarity Test2 A, detects polarity reversal
Load Test10 A, up to 2.5 kVA
Leakage Current Test0.1 – 20 mA
Safety RatingCAT II 300 V, IEC 61010
Operating Temperature0 °C to 40 °C
Storage Temperature-10 °C to 50 °C
Humidity Range20 % to 80 % non-condensing
Included AccessoriesTest leads, mains cable, carry case
Optional AccessoriesRemote probe, printer, software
Calibration Interval12 months
Warranty1 year
LanguagesEnglish, French, German, Spanish
Manual TypePDF user manual (20 pages)

Frequently Asked Questions - PAT120 Megger

How do I perform an insulation resistance test with the PAT120?
Connect the test leads to the appliance and select the insulation resistance function. Choose 250 V or 500 V test voltage, then press the test button. The result will be displayed in MΩ.
What is the maximum test voltage for insulation testing?
The PAT120 offers two insulation test voltages: 250 V and 500 V.
How can I replace the fuse in the PAT120?
Disconnect the device from the mains. Open the fuse holder on the side panel. Replace the blown fuse with one of the same rating (e.g., 1 A, 250 V). Close the holder securely.
What does error code E1 mean on the PAT120?
Error code E1 indicates a test lead connection issue. Check that the leads are securely connected and not damaged. Reconnect and try again.
Can the PAT120 test IT equipment?
Yes, but IT equipment may require a soft start or specific test sequence. Refer to the manual for guidance on testing sensitive electronics.
How to clean the Megger PAT120?
Use a dry, lint-free cloth to wipe the exterior. Do not use solvents or abrasive cleaners. Keep the test leads and connectors clean.
What is the weight of the PAT120?
The device weighs approximately 3.5 kg, making it portable for field use.
How do I update the firmware on the PAT120?
Firmware updates are done via the Megger software and a USB connection. Download the latest firmware from the Megger website and follow the update instructions.
Where can I find the serial number on the PAT120?
The serial number is located on the rear panel label near the power input. It is also found in the 'Settings' menu under 'Info'.
Is the PAT120 suitable for testing 3-phase appliances?
Yes, with the appropriate adapter (optional). The PAT120 can test 3-phase appliances by sequentially testing each phase against neutral and earth.

User questions about PAT120 Megger

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Measuring equipment in PDF format for free! Find your manual PAT120 - Megger and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. PAT120 by Megger.

USER MANUAL PAT120 Megger

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Megger

Model : PAT120

Category : Measuring equipment