MV DAC-30 - Measuring equipment Megger - Free user manual and instructions
Find the device manual for free MV DAC-30 Megger in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Product Type | Damped AC Voltage Test System |
| Model | MV DAC-30 |
| Brand | Megger |
| Dimensions (approx.) | 500 x 400 x 300 mm (19.7 x 15.7 x 11.8 in) |
| Weight (approx.) | 20 kg (44 lbs) |
| Power Supply | 230 V AC, 50/60 Hz, single phase |
| Rated Output Voltage | 30 kV peak (damped AC) |
| Output Frequency Range | 0.1 Hz to 1 Hz (damped AC) |
| Main Functions | Damped AC voltage withstand test, cable fault location, sheath testing |
| Measurement Modes | DAC (Damped AC), VLF (Very Low Frequency), DC (optional) |
| Safety Features | High-voltage interlock, emergency stop, ground connection monitoring |
| Interface | Touchscreen display with intuitive menu navigation |
| Data Storage | Internal memory for test results, USB export |
| Protection Class | IP54 (enclosure), suitable for field use |
| Operating Temperature | 0°C to 50°C (32°F to 122°F) |
| Standards Compliance | IEC 60060-3, IEEE 400.2 |
| Maintenance | Annual calibration recommended, clean with dry cloth |
| Spare Parts and Repairability | Replaceable high-voltage cable, fuse, and connectors; authorized service centers |
| Accessories Included | HV output cable, grounding set, power cord, user manual |
Frequently Asked Questions - MV DAC-30 Megger
What is the MV DAC-30 used for?
The Megger MV DAC-30 is used for damped AC (DAC) voltage testing of medium voltage cables, including withstand tests and fault location.
What is the maximum output voltage?
The maximum output voltage is 30 kV peak in damped AC mode.
What power supply does the MV DAC-30 require?
It requires a 230 V AC, 50/60 Hz, single-phase power supply.
How do I ensure safety while using the MV DAC-30?
Always use the high-voltage interlock, connect the ground cable properly, and follow the safety instructions in the manual. Never touch output terminals when energized.
Can the MV DAC-30 perform DC testing?
Yes, it has an optional DC test mode for additional diagnostics.
How often should the MV DAC-30 be calibrated?
Annual calibration is recommended to maintain measurement accuracy. Contact Megger or an authorized service center.
What types of cables can be tested with the MV DAC-30?
It is suitable for medium voltage cables (up to 30 kV) with capacitive loads. Typical applications include distribution and industrial cables.
Does the MV DAC-30 have data storage?
Yes, it has internal memory for storing test results and a USB port for data export.
What accessories are included with the MV DAC-30?
It comes with an HV output cable, grounding set, power cord, and user manual.
How do I clean the MV DAC-30?
Use a soft, dry cloth to clean the enclosure. Do not use solvents or water. Ensure the unit is turned off and disconnected.
User questions about MV DAC-30 Megger
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.
Download the instructions for your Measuring equipment in PDF format for free! Find your manual MV DAC-30 - Megger and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. MV DAC-30 by Megger.