| Product Type | Floor Standing Air Conditioner |
| Indoor Unit Dimensions (H x W x D) | 1850 x 500 x 250 mm |
| Outdoor Unit Dimensions (H x W x D) | 900 x 870 x 320 mm |
| Indoor Unit Weight | 38 kg |
| Outdoor Unit Weight | 60 kg |
| Power Supply | 230V / 50Hz / 1-phase |
| Cooling Capacity (Nominal) | 6.0 kW |
| Heating Capacity (Nominal) | 6.8 kW |
| Energy Efficiency Ratio (EER) | 3.2 |
| Coefficient of Performance (COP) | 3.6 |
| Refrigerant Type | R32 |
| Operating Temperature Range (Cooling) | -10°C to 46°C |
| Operating Temperature Range (Heating) | -15°C to 24°C |
| Indoor Sound Power Level | 45 - 60 dB(A) |
| Outdoor Sound Pressure Level | 55 dB(A) |
| Air Flow Rate (Indoor Unit) | 900 m³/h |
| Functions | Auto Restart, Programmable Timer, Sleep Mode, Swing Louver, Filter Cleaning Indicator, Self-Cleaning |
| Air Filter Type | Washable, Electrostatic |
| Installation Requirement | Professional installation recommended |
| Warranty | 2 years |
| Maintenance | Clean filter every 3 months, annual professional service |
| Safety Features | Overheat protection, auto shut-off, child lock (remote control) |
Frequently Asked Questions - FFA60A2VEB9 DAIKIN
What is the recommended installation height for the indoor unit?
For optimal airflow, install the indoor unit at least 15 cm from the ceiling and 10 cm from walls. Follow the dimensions in the installation manual.
How often should I clean the air filter?
Clean the air filter every 3 months or more frequently in dusty environments. A clogged filter reduces efficiency and may cause frosting.
Can I use this air conditioner in winter?
Yes, this model is a heat pump and can provide heating down to -15°C outdoor temperature.
Why is my air conditioner leaking water?
Common causes: clogged drain pipe, dirty filter, or improper installation. Clean the drain pipe and filter, and ensure the unit is level.
What do the error codes on the remote mean?
Error codes indicate specific faults. Refer to the manual's troubleshooting section. Common codes include E0 (sensor error) and E3 (refrigerant leak).
How do I enable the sleep mode?
Press the SLEEP button on the remote. The temperature will gradually adjust to provide comfort while saving energy.
Is this air conditioner compatible with a smart home system?
This model does not include built-in Wi-Fi. However, you can use a third-party smart plug for basic on/off control, or install a Daikin Wi-Fi adapter (sold separately).
What is the maximum length for refrigerant piping?
The maximum total piping length is 30 meters with a maximum vertical lift of 20 meters. Exceeding these limits may reduce performance.
How do I reset the filter cleaning indicator?
After cleaning the filter, press and hold the FILTER RESET button on the remote for 3 seconds until the indicator turns off.
What type of refrigerant does this unit use?
This unit uses R32 refrigerant, which has lower environmental impact than R410A and is more energy efficient.
User questions about FFA60A2VEB9 DAIKIN
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.
Download the instructions for your Air Conditioning in PDF format for free! Find your manual FFA60A2VEB9 - DAIKIN and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. FFA60A2VEB9 by DAIKIN.