T6-1000 - Measuring equipment FLUKE - Free user manual and instructions
Find the device manual for free T6-1000 FLUKE in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Type | Non-Contact Voltage Tester & Continuity Tester |
| Model | T6-1000 |
| Brand | Fluke |
| Voltage Range (AC/DC) | 1000 V |
| Current Range (AC) | 0.1 A to 200 A |
| Resistance Range | Up to 100 kΩ |
| FieldSense Technology | Yes, measures voltage and current without test leads |
| Continuity Detection | Audible beeper & visual indication |
| Dimensions | 210 x 60 x 35 mm (8.3 x 2.4 x 1.4 in) |
| Weight | 260 g (9.2 oz) including batteries |
| Power Supply | 2 x AAA alkaline batteries (1.5 V) |
| Battery Life | Approximately 200 hours typical |
| Display | Digital LCD, 6000 counts |
| Safety Rating | CAT IV 600V, CAT III 1000V |
| IP Rating | IP42 (protected against small objects and dripping water) |
| Operating Temperature | -10 °C to 50 °C (14 °F to 122 °F) |
| Storage Temperature | -30 °C to 60 °C (-22 °F to 140 °F) |
| Humidity | 10% to 90% RH non-condensing |
| Maintenance | Clean with damp cloth; no solvents; replace batteries when low |
| Safety Compliance | IEC 61010-1, IEC 61010-2-033 |
| Included Accessories | Batteries including (2 x AAA), quick reference guide |
| Warranty | 3 years |
Frequently Asked Questions - T6-1000 FLUKE
What is FieldSense technology?
FieldSense technology allows the T6-1000 to measure voltage and current without needing test leads. It uses the fork-shaped jaw to detect electric fields, providing accurate readings safely.
How do I measure current with the T6-1000?
Open the jaw and clamp it around a single conductor. The meter will automatically display the AC current value. Ensure the conductor is not carrying more than 200 A.
Can the T6-1000 measure DC current?
No, the T6-1000 measures AC current only. For DC current, you would need a different meter like the Fluke 376 FC.
What is the maximum voltage the T6-1000 can measure?
It can measure up to 1000 V AC and 1000 V DC using the FieldSense or test lead modes.
How do I replace the batteries?
Turn off the meter. Remove the battery door screw (if any) and slide off the cover. Replace the two AAA batteries with fresh ones, ensuring correct polarity. Reattach the cover.
Is the T6-1000 safe for CAT IV environments?
Yes, it is rated CAT IV 600 V and CAT III 1000 V, making it suitable for distribution boards and outdoor installations.
How do I test continuity?
Select the continuity range (Ω with beeper symbol). Touch the test leads together to verify the beeper works. Then probe the circuit; if resistance is below about 50 Ω, the beeper sounds.
What does the 'OL' display mean?
'OL' stands for Over Limit. It means the measured value exceeds the maximum range of the selected function. Select a higher range if available, or check the circuit.
Can I measure resistance with FieldSense?
No, resistance measurements require the test leads. FieldSense is for voltage and current only.
How do I clean the T6-1000?
Use a damp cloth with mild soap and water. Do not use solvents or abrasive cleaners. Ensure the meter is dry before use.
User questions about T6-1000 FLUKE
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.
Download the instructions for your Measuring equipment in PDF format for free! Find your manual T6-1000 - FLUKE and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. T6-1000 by FLUKE.