HS60 - Ultrasonic cleaner SAMSUNG - Free user manual and instructions

Find the device manual for free HS60 SAMSUNG in PDF.

SAMSUNG HS60 - Ultrasonic cleaner
📄 282 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice SAMSUNG HS60 - page 11
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Ultrasonic Cleaner
Brand Samsung
Model HS60
Dimensions (L x W x H) Approx. 200 x 150 x 120 mm
Tank Capacity 600 ml
Power Supply AC 220-240V, 50/60 Hz
Ultrasonic Frequency 42 kHz
Timer Setting Up to 30 minutes, adjustable
Main Functions Ultrasonic cleaning, degassing, timer, auto shut-off
Operation Method Touch button or dial control
Material Stainless steel tank, ABS plastic body
Weight Approx. 1.2 kg
Maintenance Clean tank after each use; wipe dry; descale monthly
Cleaning Agent Compatibility Water or mild cleaning solution; avoid flammable solvents
Safety Features Auto shut-off, overheat protection, water level sensor
Spare Parts Available Replacement tank, transducer, control board
Repairability Modular design; user-serviceable with manual
General Information Ideal for cleaning jewelry, eyeglasses, coins, small parts

Frequently Asked Questions - HS60 SAMSUNG

What items can I clean with the Samsung HS60?
The HS60 is designed for cleaning jewelry, eyeglasses, watches, coins, and other small household items. Do not clean gemstones that are porous or heat-sensitive.
What liquid should I use in the ultrasonic cleaner?
Use warm water (not hot) with a few drops of mild dish soap or a dedicated ultrasonic cleaning solution. Do not use flammable or abrasive liquids.
How long should a cleaning cycle last?
For most items, a cycle of 3-5 minutes is sufficient. Heavily soiled items may require up to 10 minutes. The timer can be set up to 30 minutes.
Can I clean electronic devices?
Only if they are fully waterproof and turned off. Submerging electronics is risky; consult your device manual first. For watches, ensure they are water-resistant.
How do I maintain the ultrasonic cleaner?
After each use, empty the tank and wipe it dry with a soft cloth. Descale monthly using a vinegar-water solution. Store in a dry place.
Why is the cleaner not starting?
Check that the tank has enough water (above the min level) and that the power cord is securely connected. The safety sensor prevents operation without water.
What does the degassing function do?
Degassing removes dissolved air from the cleaning solution, improving ultrasonic cavitation for more effective cleaning. It is especially useful for new or degassed solutions.
Can I use the HS60 continuously?
The device is not designed for continuous operation. Allow it to rest for 10 minutes after each cycle to prevent overheating.
Where can I find spare parts?
Spare parts such as the tank, transducer, and control board are available through Samsung authorized service centers or online retailers. Use only genuine parts.
Is the HS60 safe for all metals?
Yes, stainless steel, gold, silver, and platinum are safe. Avoid cleaning soft stones like pearls, opals, and emeralds, as they may be damaged by ultrasonic waves.

User questions about HS60 SAMSUNG

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

Your email remains private: it is only used to notify you if someone answers your question.

No questions yet. Be the first to ask one.

Download the instructions for your Ultrasonic cleaner in PDF format for free! Find your manual HS60 - SAMSUNG and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. HS60 by SAMSUNG.

USER MANUAL HS60 SAMSUNG

Version 1.00

HS50/HS60

User Manual

English

Table of Contents – Volume 2

Chapter 6 Starting Diagnosis

System Power 6-3

Turning the Power On 6-3

Shutting Down the System....6-3

Probes and Applications 6-4

Selecting Probes and Applications 6-5

Creating UserPreset 6-5

Modifying UserPreset....6-5

Deleting UserPreset....6-5

Patient Information 6-6

Patient Information for Each Application 6-9

Searching Patient Information....6-16

Chapter 7 Diagnosis Modes

Information....7-3

Types of Diagnosis Modes....7-3

Basic Use 7-5

Basic Mode 7-8

2D Mode 7-8

M Mode 7-23

Color Doppler Mode 7-26

Power Doppler Mode....7-31

PW Spectral Doppler Mode 7-33

CW Spectral Doppler Mode 7-38

TDI Mode 7-40

TDW Mode 7-41

ElastoScan Mode 7-42

Combined Mode 7-51

2D/C/PW Mode 7-51 2D/PD/PW Mode 7-51 2D/C/CW Mode 7-51 2D/C/M Mode 7-51 2D/TDI/TDW Mode 7-52 Dual Live Mode 7-52

Multi-Image Mode 7-53

Dual Mode 7-53 Quad Mode 7-54

3D/4D Mode 7-55

3D Stand By 7-59 3D View – MPR 7-61 5D Follicle 7-69 VOCAL 7-71 3D XI 7-78 XI VOCAL 7-88 XI STIC 7-95 4D 7-98 3D Utility Menu 7-99

Chapter 8 Measurements and Calculations

Measurement Accuracy 8-3

Causes of Measurement Errors 8-3 Optimization of Measurement Accuracy 8-5 Measurement Accuracy Table 8-7

Basic Measurements 8-9

Distance Measurement 8-13 Circumference and Area measurement 8-23 Volume Measurement 8-26

Calculations by Application 8-29

Things to Note 8-29

Common Measurement Methods 8-33

OB Calculations 8-37

Fetal Heart Calculations 8-46

Gynecology Calculations 8-49

Cardiac Calculations 8-52

Abdomen Calculations 8-66

Pediatric Hips Calculations 8-68

Urology Calculations 8-70

Small Parts Calculations 8-71

Musculoskeletal Calculations 8-75

Vascular Calculations 8-76

Reports 8-85

Viewing Reports 8-85

Report Preview 8-86

Editing Report (Worksheet) 8-89

Adding Comments 8-92

Print Reports....8-94

Saving Reports....8-94

Store SR 8-95

Images 8-95

OB Graph 8-97

Description 8-102

Closing Reports....8-104

Chapter 9 Image Managements

Cine/Loop 9-3

Annotating Images....9-5

Annotation 9-5

BodyMarker 9-10

Saving, Playing and Transferring Images 9-12

Saving Images....9-12

Playing Images 9-13

Transferring Images....9-14

Printing Images 9-15

Printing Images 9-15

SonoView Mode....9-16

Exam List....9-17

Review – Exam Mode 9-19

Review – Compare Mode....9-24

DICOM Q/R....9-31

**Reference Manual

Samsung Medison is providing an additional HS50/HS60 Reference Manual (English version).

Starting Diagnosis

System Power 6-3

Turning the Power On 6-3

Shutting Down the System 6-3

■ Probes and Applications 6-4

Selecting Probes and Applications....6-5

Creating UserPreset 6-5

Modifying UserPreset 6-5

Deleting UserPreset 6-5

■ Patient Information ...... 6-6

Patient Information for Each Application....6-9

Searching Patient Information......6-16

:: System Power

Boot up the system for use.

SAMSUNG HS60 - :: System Power - 1

CAUTION: Make sure to connect the probes and peripheral devices that will be used before powering on the system. If you attempt to connect them during system use, it may lead to patient injury or irreparable damage to the console.

Turning the Power On

Press the On/Off button when the power is off. Booting begins, and the product logo appears on the screen. When booting is completed, the 2D mode screen appears in End Exam status.

SAMSUNG HS60 - Turning the Power On - 1

CAUTION: Before starting the diagnosis, you must register the patient information.

SAMSUNG HS60 - Turning the Power On - 2

NOTE:

The product should turn on about 10 seconds after the power switch at the back of the product is turned on. During system booting, do not press any key on the keyboard. It may cause product malfunction. If you turn on the power after turning it off suddenly, the system may turn on and off momentarily. This is one of the characteristics of the Intel PC main board, not a system error.

Shutting Down the System

Press the On/Off button while using the system to initiate shutdown.

SAMSUNG HS60 - Shutting Down the System - 1

CAUTION:

When the system is not turned off, holding down the On/Off button for five seconds or longer forces the product to power off. If the ultrasound system is unplugged while working or turned off by forcibly shutting down, the files may get corrupted and it may result in system down or data loss. To ensure that the product is safely cut off from electrical power, set the power switch at the rear of the product to Off position after using the product.

Probes and Applications

Before scanning, select a probe and an application.

SAMSUNG HS60 - Probes and Applications - 1

CAUTION: Refer to 'Chapter 5. Probes' for more information on probes and applications supported by the system.

Probe Selection Screen

Press the Probe button on the Touch Screen to load the Probe Selection screen. In this screen, you can select/change probe or application you want to use and change the probe presets.

The Probe Selection screen is divided into four lists.

① Probe list: Displays a list of probes currently connected to the system. ② Application list: Displays a list of applications the selected probe supports. ③ Preset list: Displays a list of presets the selected application supports. ④ UserPreset list: Displays a list of presets you can configure according to your preferences.

LA3-14AD CA1-7AD PE2-4 EA2-11B OB Abdomen GYN Pediatric Small Parts Vascular MSK 1st Trimester 2nd Trimester 3rd Trimester Fetal Heart Preset Setup Save +

[Figure 6.1 Probe Selection]

Selecting Probes and Applications

The selected probe, preset, or userpreset appear in the screen area of the monitor screen.

  1. Select the items in the following order: Probe → Application → Preset/UserPreset.
  2. When you select Preset/UserPreset, the system automatically applies your selections and switches to Diagnosis mode. Press the Probe button to cancel.

Creating UserPreset

  1. Tap + on the touch screen to create a UserPreset.
  2. The Preset setup window will open.
  3. Enter the name you want to use and tap Save. Tap Close to cancel.

Modifying UserPreset

  1. Enter the Preset Setup by tapping Preset Setup on the touch screen.
  2. Select a Preset to rename and press Rename.
  3. The Preset setup window will open.
  4. In the Preset setup window, enter a new Preset name and press Save. To cancel it, tap Close.

Deleting UserPreset

  1. Enter the Preset Setup by tapping Preset Setup on the touch screen.
  2. After selecting a preset to delete, tap Delete.
  3. The Preset setup window will open.
  4. Tap Delete to delete the UserPreset. Tap Close to cancel it.

Patient Information

Press the Patient button on the control panel to display the Patient Information screen.

This screen allows you to enter, search, or modify patient information. Patient information includes basic details such as patient ID, name, date of birth, and gender, as well as additional application-specific information.

SAMSUNG HS60 - Patient Information - 1

NOTE: The ID is required.

Entering Basic Patient Information

Enter or modify general patient information in the General Information section.

Use the trackball to move the pointer to the desired field. Tap a button on the touch screen to enter information using the touch screen.

After entering information, click OK on the screen or tap OK on the touch screen to save. Click Cancel or tap Cancel on the touch screen to cancel.

Patient Patient ID Date of birth (Age) YYYY-MM-DD Gender None Indication Study Information Height cm Weight kg Application Cardiac BSA m² Accession Number Diag. Physician Ref. Physician Operator Description Search Hide Search by Patient ID Patient ID Patient Name Date of Birth Gender Exam Date Appli…

[Figure 6.2 General Patient Information]

Patient Worklist Auto ID Creation New Patient Start EzExam+ Search by Patient ID Patient Name Date of Birth Today Last Week Last Month Exam Date Review Images SonoView Send Delete Exam List Review Exam EzCompare OK Cancel

[Figure 6.3 General Patient Information – Touch Screen]

Patient ID

Enter a patient ID.

Last Name

Enter the patient's last name.

First Name

Enter the patient's first name.

Middle Name

Enter the patient's middle name.

SAMSUNG HS60 - Middle Name - 1

NOTE: The name that you have entered will appear in the title area and reports.

Date of Birth (Age)

Enter the patient's date of birth in the specified format.

Gender

Select the patient's gender.

Accession Number

When viewing the worklist for a patient via the DICOM server, this information is automatically displayed in the appropriate fields.

Diag. Physician

Enter the name of the physician who diagnosed the patient.

Ref. Physician

Enter the name of the referring physician.

Operator

Enter the name of the operator who scanned the patient. Up to 20 persons may be entered.

Search through the information stored in the system.

Worklist

Perform a search by connecting to the DICOM Modality Worklist server in the hospital network.

New

Enter new patient information.

Auto ID Creation

Create temporary patient information using a temporary ID.

Keyboard

Use the keyboard displayed on the touch screen to enter text.

Start Ez Exam+

This function helps you to link an exam with Ez Exam+ when the exam starts.

Patient Information for Each Application

In Study Information, enter additional patient information or change the existing patient information for each application.

  1. Use Application on the monitor to select an application.
  2. Enter additional information required for diagnosis.

OB

Select OB from Application. Enter the additional obstetrical information.

LMP

Enter the last menstrual period for a patient.

DOC

Indicates the patient's date of conception.

EDD

Indicates the patient's expected date of delivery.

GA (LMP)

Indicates the gestational age of a patient.

Ovulation Date

Enter expected ovulation date in accordance with defined format

Day of Cycle

Enter length of menstrual cycle in days (Date).

Fetuses No.

Enter the number of fetuses. Up to four may be entered.

Gravida

Enter the number of pregnancies.

Para

Enter the number of deliveries.

Aborta

Enter the number of miscarriages.

Ectopic

Enter the number of ectopic pregnancies.

Description

Enter a description of the diagnosis.

SAMSUNG HS60 - Description - 1

NOTE:

Refer to 'Chapter 3. Utilities' Setup > System > Patient > User Defined List. Up to 20 persons may be entered per application.

Study Information Application OB LMP DOC Ovulation Date YYYY-MM-DD Accession Number YYYY-MM-DD EDD (LMP) GA (LMP) Day of Cycle Diag. Physician W d Fetuses No. Gravida Para Aborta Ectopic Ref. Physician 1 Description Operator

[Figure 6.4 Study Information - OB]

SAMSUNG HS60 - NOTE: - 2

GYN

Select GYN from Application. Enter additional information for Gyn. This is the same information as for OB.

Study Information Application GYN LMP Ovulation Date YYYY-MM-DD YYYY-MM-DD Gravida Para Aborta Ectopic Description Accession Number Diag. Physician Ref. Physician Operator

[Figure 6.5 Study Information - GYN]

SAMSUNG HS60 - GYN - 2

Urology

Select Urology from Application. Enter urological information.

PSA

Enter the Prostate Specific Antigen (PSA) value.

PPSA Coefficient 1

Enter predicted PSA coefficient 1.

PPSA Coefficient 2

Enter predicted PSA coefficient 2.

Study Information Application Urology PSA PPSA Coefficient 1 PPSA Coefficient 2 Description Accession Number Diag. Physician Ref. Physician Operator

[Figure 6.6 Study Information – Urology]

SAMSUNG HS60 - PPSA Coefficient 2 - 2

Vascular

Select Vascular from Application. Enter vascular-related information.

Left Systole

Enter left systole blood pressure.

Left Diastole

Enter left diastole blood pressure.

Right Systole

Enter right systole blood pressure.

Right Diastole

Enter right diastole blood pressure.

Study Information Application Vascular Left Systole Left Diastole mmHg mmHg Right Systole Right Diastole mmHg mmHg Description Accession Number Diag. Physician Ref. Physician Operator

[Figure 6.7 Study Information – Vascular]

SAMSUNG HS60 - Right Diastole - 2

Abdomen

Select Abdomen from Application.

Study Information Height cm Weight kg Description Application Abdomen Accession Number Diag. Physician Ref. Physician Operator

[Figure 6.8 Study Information – Abdomen]

Height

Enter the patient's height. Enter height in cm, ft, or in.

Weight

Enter the patient's weight. Enter weight in kg, lb, or oz.

SAMSUNG HS60 - Weight - 1

MSK

Select MSK from Application.

Study Information Application MSK Description Accession Number Diag. Physician Ref. Physician Operator

[Figure 6.9 Study Information - MSK]

SAMSUNG HS60 - MSK - 2

Pediatric

Select Pediatric from Application.

Study Information Application Pediatric Description Accession Number Diag. Physician Ref. Physician Operator

[Figure 6.10 Study Information – Pediatric]

SAMSUNG HS60 - Pediatric - 2

Small Parts

Select Small Parts from Application.

Study Information Application Small Parts Description Accession Number Diag. Physician Ref. Physician Operator

[Figure 6.11 Study Information – Small Parts]

SAMSUNG HS60 - Small Parts - 2

Cardiac

Select Cardiac in Application.

Study Information Application Cardiac Height Weight BSA Accession Number cm kg m² Description Diag. Physician Ref. Physician Operator

[Figure 6.12 Study Information – Cardiac]

Height

Enter the patient's height in cm, ft and in.

Weight

Enter the patient's body weight in kg, lb and oz.

BSA

When the height and weight are entered, the BSA (Body Surface Area) is automatically calculated and displayed.

Searching Patient Information

Search

Search through the information stored in the system.

Search Hide Search by Patient ID 20160509-033713PM Send Delete Patient ID Patient Name Date of Birth Gender Exam Date Application 20160509-03371... None 2016-05-09 Abdomen Exam List Review Images SonoView Continue Exam EzCompare

[Figure 6.13 Search]

  1. When a search term is entered in the search field, the list of patients who match the criteria will be displayed. Click the Search By button to search patients by condition.
  2. Double click a list where a desirable patient list is selected. The selected patient information will be applied to the system.

Show/Hide

Show/Hide buttons or lists in the search area.

Search by

User can enter a search criteria.

Exam List

Show the exam list for a patient selected from the patient list.

Patient 20160610-105817AM Date of Birth (Age) Gender YYYY-MM-DD None Indication Study Information Application Cardiac Height Weight BSA Accession Number cm kg m Description Diag. Physician Ref. Physician Operator Start Exbeam Exam List Exam Data Application Description Image No. Image Size 2016-06-1…

[Figure 6.14 Exam List]

Return to the search area.

Review Images

Show the image of a selected exam on Review Images screen.

Patient Review Images 2016/06/10-1958:1AM Name Continue Exam ExCompare Back Hide Annotation 2016-06-10 (5) 0 1 2 4 5 3

[Figure 6.15 Review Images]

① Continue Exam: This is activated when an exam that is less than 24 hours old is selected. The page moves to 2D image screen of the selected exam. ② Hide Annotation: Hide any annotations made to an image. ③ View Scale: Set the image size for review. Select either the Small, Mid, or Large buttons. ④ Favorite: Add/remove a selected image from Favorites. ⑤ Select/Deselect All: Select/deselect all images regardless of the exam date.

SonoView

You can review a selected exam from SonoView.

Review Exam

The exams that were performed more than 24 hours before present, and their images, are displayed. When an exam is selected, the button is activated. When enabled, you can continue to view the exam images.

Continue Exam

Exams that were performed more than 24 hours ago can be edited. When an exam is selected, the button is activated. You can use this button to go to the edit exam page.

EzCompare

Press this button to view dual image of a selected exam image and a live scan image currently filming.

Send

Send images to the DICOM server.

Delete

Delete the exam.

SAMSUNG HS60 - Delete - 1

Perform a search by connecting to the DICOM Modality Worklist server in the hospital network.

SAMSUNG HS60 - Worklist Search - 1

NOTE: A worklist search is available only when DICOM is enabled. You can select the worklist server in Setup > Connectivity > DICOM. Refer to the 'DICOM Settings' section of 'Chapter 3. Utilities'

  1. Select Worklist from Patient on the monitor or touch screen.
  2. After entering at least one item out of Patient ID, Last Name, Worklist Number (Accession Number), Procedure ID, Exam Date, and/or name of the equipment being used for exam (AE Title), click Search. The list of patients who match the criteria will be displayed.

SAMSUNG HS60 - Worklist Search - 2

Clicking items such as Date/Time or Patient Name sorts entries into alphabetical or numerical order for the selected criteria.

Select Today, Last Week, Last Month, or Manual as Exam Date.

After running a search, the date of the last update is displayed in the bottom right corner.

  1. Double click on the desired patient list. This applies the selected patient information to the system.

Patient Patient ID Last Name Accession Number Procedure ID Patient Worklist Exam Date Manual : YYYY-MM-DD : YYYY-MM-DD AE Title Any Hide Search Auto ID Creation + New Patient OK Cancel

[Figure 6.16 Search – Worklist]

Diagnosis Modes

Information 7-3

Types of Diagnosis Modes 7-3

Basic Use 7-5

Basic Mode....7-8

2D Mode....7-8

M Mode 7-23

Color Doppler Mode 7-26

Power Doppler Mode 7-31

PW Spectral Doppler Mode....7-33

CW Spectral Doppler Mode 7-38

TDI Mode....7-40

TDW Mode....7-41

ElastoScan Mode....7-42

■ Combined Mode....7-51

2D/C/PW Mode....7-51

2D/PD/PW Mode....7-51

2D/C/CW Mode....7-51

2D/C/M Mode....7-51

2D/TDI/TDW Mode....7-52

Dual Live Mode....7-52

■ Multi-Image Mode 7-53

Dual Mode....7-53

Quad Mode 7-54

Chapter 7

☐ 3D/4D Mode ....7-55

3D Stand By....7-59 3D View - MPR 7-61 5D Follicle 7-69 VOCAL....7-71 3D XI 7-78 XI VOCAL 7-88 XI STIC 7-95 4D 7-98 3D Utility Menu....7-99

Information

Types of Diagnosis Modes

This product supports a variety of diagnosis modes including Basic Mode, Combined Mode, Multi-Image Mode, and 3D/4D Mode.

Basic Mode: Consists of different modes, each of which has a specific usage and function. By default, 2D Mode is applied together with another mode. Combined Mode: For an image, two or three Basic Modes are applied at the same time. By default, 2D Mode is applied together with another mode. An image is viewed in a single screen. Multi-Image Mode: The screen is divided into two (dual) or four (quad) sub screens, each of which is used to view an image. Since each sub screen can display a different image, it can be a very useful feature, allowing multilateral views of an organ. 3D/4D Mode: 3D and 4D images can be obtained.

The types of diagnosis mode that are available with the product are shown below:

Mode Type
Basic Mode2D ModeColor Doppler ModePower Doppler ModeM ModePW Spectral Doppler ModeCW Spectral Doppler ModeTDI (Tissue Doppler Imaging) ModeTDW (Tissue Doppler Wave) ModeElastoScan Mode
Combined Mode2D/C/PW Mode2D/PD/PW Mode2D/C/CW Mode2D/PD/CW Mode2D/C/M Mode2D/TDI/TDW ModeDual Live Mode
Multi-Image ModeDual ModeQuad Mode
3D/4D Mode3D Mode4D Mode

SAMSUNG HS60 - Types of Diagnosis Modes - 1

NOTE: The functionalities for each mode may be restricted by the selected probe.

Basic Use

The items that are commonly used in each diagnosis mode are shown below:

SAMSUNG HS60 - Basic Use - 1

Using the Control Panel

The items that can be used in each diagnosis mode are provided as menu items. You can change the image format or optimize an image to facilitate your diagnosis.

Gain

Use the dial-button on the control panel. The Gain button appears differently depending on the diagnosis mode, but it is usually in the form of a dial-button used to select a diagnosis mode.

You can adjust the brightness of an image. If you rotate the Gain dial-button clockwise, its value increases.

TGC (Time Gain Compensation)

Tap the TGC button on the touch screen to open the TGC window for use.

In general, ultrasound penetration gets weaker with depth. TGC can be used to compensate for this effect.

The product provides eight TGC sliders for varying depths, allowing you to adjust Gain by area. Among the eight sliders, the top slider represents the shallowest area, while the lower sliders represent the deeper ones.

Move the slider to the right to increase Gain, brightening the image.

When the TGC preset is selected, the TGC preset is applied to the system and then the system is switched to diagnosis mode. The user can adjust TGC as needed, and press Save to save it for use.

Focus

Use the Focus switch on the control panel to adjust the location of the focus.

Depth

Use the Depth switch on the control panel to adjust the image scanning depth. The allowable range for adjustment varies depending on the probe type.

Zoom

Use the Zoom dial-button on the control panel.

You can magnify an image. An image can be magnified by either Read Zoom or Write Zoom.

Read Zoom: This function is used for zooming in on images that are stored on the hard disk.

  1. Rotate the Zoom dial-button on the control panel.
  2. Adjust the position of the zoomed-in screen with the trackball.
  3. Observe the magnified image.

Write Zoom: This function allows you to magnify and scan an image in real time.

  1. Press the Zoom dial-button on the control panel. The Write Zoom box will appear on the screen.
  2. Use the Change button to move and resize the Zoom box.
  3. To finish Zoom mode, press the Zoom dial-button once again. Or press the Exit button on the control panel.

Quick Scan

SAMSUNG HS60 - Quick Scan - 1

NOTE: The Quick Scan function is available in all probes' applications.

Use the Q Scan button on the control panel. The 'Q Scan' icon mark will appear at the top of an image.

In 2D Mode, it is used to optimize the contrast and brightness of an image by adjusting Gain and TGC automatically. In PW Spectral Doppler Mode, it is used to optimize the spectrum by adjusting Scale and Baseline automatically.

To finish QuickScan mode, press the Exit button on the control panel.

SAMSUNG HS60 - Quick Scan - 2

Using Touch Screen Menus

The items that can be used in each diagnosis mode are provided as touch screen menu items. You can change the image format or optimize an image to facilitate your diagnosis.

  1. In diagnosis mode, the menu for the diagnosis mode currently being used is displayed on the touch screen. In a combined mode that uses more than one diagnosis mode, tap the relevant tab on the touch screen to specify settings for each mode.
  2. Select a value by pressing a button or by rotating the dial-button on the control panel.

Basic Mode

2D Mode

This basic mode, also referred to as B Mode (Brightness mode), provides scan planes of organs. This is used to display two-dimensional anatomy images in the direction of scanning in real time.

SAMSUNG HS60 - 2D Mode - 1

Entering 2D Mode

SAMSUNG HS60 - Entering 2D Mode - 1

NOTE: Because 2D Mode is applied by default for all diagnosis modes, it cannot be terminated.

Press the 2D dial-button on the control panel.

If you press the 2D dial-button in other diagnosis modes, it will switch to the basic 2D Mode.

SAMSUNG HS60 - Entering 2D Mode - 2

2D Mode Menu

2D Harmonic Frequency Line Density L/R Flip < Res > < Medium > S-Harmonic ClearVision Biopsy Guide U/D Flip < 5 > < Off > Dual Live MultiVision Trapezoid Rotation < Medium > ElastoScan Panoramic Needle Mate+ Edge Enhance < Off > DR 126 Focus Number 1 Image Size 8S Steer Angle 0 Power 90 Frame Averag…

[Figure 7.1 2D Mode - Touch Screen]

Harmonic

Turn this function on or off by tapping Harmonic on the touch screen. The image information will show the 'Har' mark. This product provides the OHI (Optimal Harmonic Imaging) high frequency function to optimize images.

SAMSUNG HS60 - Harmonic - 1

NOTE: The Harmonic function only works with certain probes.

Frequency

Tap Frequency on the touch screen. This enables you to configure the probe's frequency.

The selected frequency is displayed in the image area of the monitor, allowing you to easily determine the state of the current frequency.

▶ Res2 (Resolution): The highest frequency ▶ Res1 (Resolution): High frequency ▶ Gen (General): General frequency Pen1 (Penetration): Low frequency Pen2 (Penetration): The lowest frequency

Line Density

Tap Line Density on the touch screen. Set the scan line density. Select Low, Med, or High by tapping the button.

Selecting High increases the number of scan lines and improves the image resolution. However, the frame rate is reduced.

L/R Flip (Left/Right Flip)

Tap L/R Flip on the touch screen.

Pressing this button flips the image horizontally (Left/Right Flip). The direction marker on the top of the image indicates the orientation of the current image.

S-Harmonic

Turn this function on or off by tapping S-Harmonic on the touch screen. The 'S-HAR' mark will be displayed in the Image Information.

Tap the S-Harmonic button on the touch screen. S-Harmonic inverts the pulses to sharpen the displayed image. If it is On, the phrase 'S-Harmonic' will be shown in the image information.

SAMSUNG HS60 - S-Harmonic - 1

NOTE:

The Harmonic and S-Harmonic functions are only available for specific probes. ▶ S-Harmonic function may show lines in the near field of certain probes when non-scan mode is used. This is due to the technical features that improve the sensitivity and resolution of the ultrasound images and does not cause any problems in scan mode.

ClearVision

Tap ClearVision on the touch screen. When turned on, ClearVision removes noise from the image and enhances outlines to help show the image more clearly. The 'ClearVision' mark will be displayed in the Image Information.

Tap the touch screen button to select an Index between 1 and 5. Select Off to turn off the feature.

Biopsy Guide

Tap Biopsy Guide on the touch screen.

SAMSUNG HS60 - Biopsy Guide - 1

NOTE: Make sure to adjust the biopsy guideline before using the biopsy feature.

2D Harmonic Frequency Res > Line Density Medium > L/R Flip S-Harmonic ClearVision 5 > Biopsy Guide 1 > U/D Flip Dual Live MultiVision Medium > Trapezoid Rotation 0 ° > ElastoScan Panoramic Needle Mate* Off > Edge Enhance TGC DR 126 Focus Number 1 Image Size 85 Steer Angle 0 Power 90 Frame Average 6…

[Figure 7.2 Biopsy]

Tips!

Setting the Biopsy Guideline

SAMSUNG HS60 - Setting the Biopsy Guideline - 1

NOTE:

If the system is rebooted, the biopsy guideline settings are restored to the default. Make sure to adjust the biopsy guideline before using the biopsy feature.

▶ Support for Multiple Guidelines

If the probe supports multiple biopsy angles, the user may select the biopsy guide angle as desired.

Starting and Finishing a Biopsy

  1. Tap Biopsy Guide on the touch screen.
  2. Insert the needle along the guideline. And then perform the biopsy as desired.
  3. When all procedures are complete, tap Biopsy Guide again to turn this Off. Biopsy will end.

Biopsy Guide Edit Mode

SAMSUNG HS60 - Biopsy Guide Edit Mode - 1

NOTE:

▶ Only available in 2D mode and Single mode. Not available in Dual Live or Freeze state. Not available in Write Zoom or Read Zoom state.

Starting and Ending Biopsy Guide Edit Mode

  1. Tap Biopsy Guide on the touch screen.
  2. Use the Angle dial-button on the control panel to enter Biopsy Guide Edit mode.
  3. When you enter Biopsy Guide Edit mode, Angle Offset appears.
  4. Rotate the Angle dial-button to select Angle Offset or Lateral Offset.
  5. Angle Offset: This is the angle for the currently selected biopsy guide; the maximum adjustable offset is the guideline's outer line angle. Adjustments can be made in 0.1° increments.
  6. Lateral Offset: This is the lateral direction for the currently selected biopsy guide. Adjustments can be made in 0.1 mm increments.
  7. Press the Angle dial-button to exit Biopsy Guide Edit mode.

U/D Flip (Up/Down Flip)

Tap U/D Flip on the touch screen.

Each press of the button flips the image vertically.

Dual Live

Tap Dual Live on the touch screen and select On or Off.

View the 2D/Color Doppler images of the scanned area simultaneously in real time.

When viewing Cine images in Dual Live mode, various settings are applied only to the Cine image on the right side, allowing you to compare it with the unaffected Cine image on the left side.

MultiVision

Tap MultiVision on the touch screen. MultiVision uses a multi-beam to improve the image quality displayed on the screen. When this feature is turned on, the 'MultiVision' mark will be displayed in the image information. Tap the button on the touch screen to set MultiVision to Low, Med, or High. Note that MultiVision can only be set to Low in 2D/C Mode. Select Off to turn off the feature.

SAMSUNG HS60 - MultiVision - 1

NOTE: This feature only works with certain probes. For more information, refer to 'Probe List' in 'Chapter 5. Probes'.

Trapezoid

Tap Trapezoidal on the touch screen to turn it on or off.

The rectangular frame provided by a Linear Probe is changed to a trapezoidal shape. This allows a wider view of an image.

SAMSUNG HS60 - Trapezoid - 1

NOTE: Trapezoid function only works with Linear probes.

Rotation

Tap Rotation on the touch screen to rotate a 2D image. Select a rotation angle to either 0° , 90° , 180° , or 270° .

ElastoScan

Tap ElastoScan on the touch screen. For more information, please refer to 'ElastoScan Mode' in this chapter.

SAMSUNG HS60 - ElastoScan - 1

NOTE:

▶ ElastoScan is an optional feature of this product. This feature only works with certain probes. For more information, refer to 'Probe List' in 'Chapter 5. Probes'.

Panoramic

Tap Panoramic on the touch screen. For more information, please refer to 'Panoramic' in this chapter.

SAMSUNG HS60 - Panoramic - 1

NOTE:

▶ Panoramic is an optional feature of this product. This feature only works with certain probes. For more information, refer to 'Probe List' in 'Chapter 5. Probes'.

Needle Mate+

Tap Needle Mate+ on the touch screen. Needle Mate+ is a feature that helps visualize the biopsy needle clearly in an ultrasound image. Choose the direction to optimize the image between From Left and From Right. Select Off to turn off the feature.

From Left From Right
DescriptionFrom the upper left to lower right or from the lower right to upper left.From the upper right to lower left or from the lower left to upper right.
PurposeSelect this if the needle is being inserted from the upper left to lower right or from the lower right to upper left.Select this if the needle is being inserted from the upper right to lower left or from the lower left to upper right.

When turned on, Needle Enhance and Needle Angle are enabled.

SAMSUNG HS60 - Needle Mate+ - 1

NOTE:

▶ Needle Mate+ is an optional feature of this product. This feature only works with certain probes. For more information, refer to 'Probe List' in 'Chapter 5. Probes'.

Needle Enhance

This feature only works when Needle Mate+ is on. Select 1, 2, 3, or 4 by tapping the button on the touch screen to select the degree of needle enhancement.

1: The needle is thin with weak enhancement. ▶ 2: The needle is thin with strong enhancement. 3: The needle is thick with weak enhancement. 4: The needle is thick with strong enhancement.

Needle Angle

Needle Angle is a function to set the needle injection angle for efficient beam steering and needle enhancement. Select one from either Shallow, Medium, or Steep.

DR (Dynamic Range)

Select a value between 30 and 256 by using the DR dial-button on the touch screen. The Dynamic Range function adjusts contrast by changing the ratio of the minimum and maximum values of the input signals. When this value increases, the image is displayed more smoothly.

Frame Average

Tap the Frame Average dial-button on the touch screen. Select a value between 0 and 9 by using the dial-button on the touch screen. Use this to minimize the appearance of speckles in updated images when the same location is scanned repeatedly.

Focus Number

Change the number of focus points at the target location you wish to study. Select a value between 1 and 4 by using the dial-button on the touch screen.

Reject

Use the Reject dial-button on the touch screen to select a value between 0 and 30.

This function is used to eliminate noise or low level echo for clearer signals.

Image Size

Select a value between 70 and 100 by tapping the Image Size button on the touch screen. Used to specify 2D image size.

Gray Map

Select a value between 1 and 12 by tapping the Gray Map dial-button on the touch screen. This changes the 2D Post Curve.

Chroma Map

Use the Chroma Map dial-button on the touch screen to select either Off or a value between 1 and 11.

Edge Enhance

Allows you to view more accurate images of organ or tissue boundaries. A higher value provides more accurate images of boundaries.

Select a value between -3 and 3 by tapping the touch screen button or using the Soft Menu dial-button on the control panel.

Power

Use the Power dial-button on the touch screen to select a value between 2 and 100 for the power of the ultrasound output.

Scan Area

Use the Scan Area dial-button on the touch screen to select a value between 40 and 100 as the image width (%). Increasing the image width reduces the frame rate. You may also press the Change button on the control panel to change the trackball state to ROI Size and then use the trackball to adjust the view area.

Steer Angle

You can adjust the angle of the ultrasound beam without moving the probe by using the Steer Angle dial-button.

SAMSUNG HS60 - Steer Angle - 1

NOTE: The Steer function only appears on the soft menu when a linear probe is used.

SAMSUNG HS60 - Steer Angle - 2

CEUS+

This mode is used for imaging the contrasting effect within blood vessels by infusing an ultrasound contrast agent.

SAMSUNG HS60 - CEUS+ - 1

NOTE:

CEUS+ is supported in all countries except the USA. CEUS+ is an optional feature of this product.

CEUS+ Timer 1 Frequency Line Density < Pen > < Med > L/R Flip Timer 2 ClearVision Frame Limit < 1 > U/D Flip Dual Live Chroma Map Ref. Line Contrast CEUS+ Flash TGC Frame Average 0 Image Size 90 MI Control 0.5 Flash Frame 3 DB 120 Reject 2 Gray Map 1 Chroma Map

[Figure 7.3 CEUS+ - Touch Screen]

Tap CEUS+ on the touch screen to select on or off. When 'On' is selected, the touch screen is switched to the CEUS+ screen.

SAMSUNG HS60 - NOTE: - 2

CEUS+ Mode

CEUS stands for Contrast Enhanced Ultrasound, and aids the diagnosis by enhancing the contrast on the ultrasound image. When entering CEUS+ mode, Dual mode is displayed by default. ▶ Functions such as Harmonic and S-Harmonic are not available.

Timer 1/Timer 2

Starts or resets the timer.

Press the button to start the timer. When the button is re-tapped, the timer stops and the time is reset. If you don't tap the button again, the timer will keep running even when the CEUS+ On/Off state is changed.

Dual Live

Tap Dual Live on the touch screen and select On or Off. When 'On' is selected, Dual Live mode is activated to display both Contrast and 2D images side-by-side. When 'Off' is selected, Single mode is activated.

Ref. Line

This option displays the Ref. Line on an image. Select On or Off by tapping Ref. Line on the touch screen. The Ref. Line in CEUS+ mode is used to indicate the same location on the Agent and Tissue images in Dual Live mode.

Contrast

Select a CEUS+ type. Tap the button on the touch screen to select either Contrast or 2D.

Contrast: It displays contrast-applied images. ▶ 2D: Displays image in 2D Mode.

Flash

Tap the button on the touch screen and select On or Off. For the defined frames in Frame, brighter images are produced.

Flash Frame

Set a value between 3 and 100 frames to specify the period of time during which the Flash function will operate.

MI Control

Select a value for the mechanical index by tapping the touch screen button or by using the Soft Menu dial-button on the control panel.

Frame Average

Frame Avg averages the present image and the previous image when an image is updated. Select a value between 0 and 9 by tapping the touch screen button or using the Soft Menu dial-button on the control panel.

Reject

This function reduces noises or echoes from an image in order to make the image clearer. Select a value between 0 and 30 by tapping a button on the touch screen or using the dial-button.

Cine Play

Play or stop Cine images.

Trim Start

After specifying the position of the first frame by rotating the dial-button or using the trackball, tap the dial-button to save it.

Trim End

After specifying the position of the last frame by rotating the dial-button or using the trackball, press the dial-button to save it.

Cine Speed

Rotate the dial-button to adjust the auto playback speed.

SAMSUNG HS60 - Cine Speed - 1

NOTE: For more information on other touch screen items, refer to the '2D Mode'. (The setting values may vary depending on the selected probe type, application, and other settings.)

SAMSUNG HS60 - Cine Speed - 2

Panoramic

SAMSUNG HS60 - Panoramic - 1

NOTE: This feature only works with certain probes. For more information, refer to 'Probe List' in 'Chapter 5. Probes'.

Panoramic Imaging is the function that acquires images over a wider range by using continuous ultrasonographic images. Up to 1,000 frames can be used.

Acquiring a Panoramic Image

  1. Tap Panoramic on the touch screen. The touch screen will be switched to the Panoramic Ready screen.
  2. Tap Start/Stop on the touch screen. The system will begin to acquire a panoramic image.
  3. Press Start/Stop to finish acquiring the panoramic image. The touch screen will switch to the Panoramic Review screen.

Tips!

Things to remember when acquiring a Panoramic image

When scanning a curved surface, ensure that the scan surface and the contact surface of the probe are always at right angles. ▶ Moving in the opposite direction while acquiring an image erases the previously saved frames and saves new frames. The image quality may deteriorate if the contact surface of the probe loses contact with the scan surface. If the scan speed is fast or the angle of the contact surface of the probe changes, artifacts may occur.

Panoramic TGC Panoramic Start/Stop

[Figure 7.4 Panoramic Ready – Touch Screen]

Reviewing a Panoramic Image

SAMSUNG HS60 - Reviewing a Panoramic Image - 1

NOTE: L/R Flip, U/D Flip, and Zoom are available only when the Layout is set to Full Screen.

Panoramic L/R Flip U/D Flip Return Ruler Panoramic Layout < Full Screen >

[Figure 7.5 Panoramic Review – Touch Screen]

L/R Flip: Flip the panoramic image horizontally. ▶ U/D Flip: Flip the panoramic image vertically. ▶ Ruler: Press this button to turn this option on or off. When turned on, a ruler is displayed on the panoramic image. Layout: Specify how the panoramic image will be displayed on the screen. – Full Screen: Display the panoramic image in full screen mode. - Up/Down: Display the 2D and panoramic images at the top and bottom of the screen, respectively. - Side by side: Display the 2D and panoramic images on the left and right of the screen, respectively. ▶ Return: Return to the Panoramic Ready screen. Tap the Panoramic button again on the touch screen to exit Panoramic Imaging.

M Mode

The M Mode is used to specify an observation area in a 2D image with the M Line, and display changes over time.

This mode is appropriate for the observation of organs with a lot of movement, such as cardiac valves. The 2D Mode image is also shown, allowing the marking and adjustment of an observation area within the entire image.

2D Frequency < Gen > Display Format < Up/Down > M Sweep Speed < 44 mm/s > Display Size < 50/50 > TGC DR 120 Steer Angle 0 Power 90 M Mode Map 5 Chrono Map Off 3.1mm Distan 0

[Figure 7.6 M Mode - Touch Screen]

SAMSUNG HS60 - M Mode - 2

Entering & Exiting M Mode

Entering M Mode

  1. Press the M dial-button on the control panel.
  2. Configure settings relating to M image acquisition on the touch screen.
  3. Press the M dial-button again to enter M Mode and display the M image on the screen.

Exiting M Mode

Press the M dial-button while the M image is being displayed. You can also press the 2D dial-button to exit M Mode.

SAMSUNG HS60 - Exiting M Mode - 1

M Mode Screen

M Line

Use the trackball on the control panel to move the line to the right or left. The M Line indicates the relative position of the M Mode image in the 2D image. Therefore, you can move the M Line to change the observation area.

SAMSUNG HS60 - M Line - 1

M Mode Menu

Anatomical M

SAMSUNG HS60 - Anatomical M - 1

NOTE: Available only with the phased array probe or the cardiac application.

Tap the Anatomical M dial-button on the touch screen to turn it on or off. If it is 'On', position and angle of AMM Line can be adjusted.

▶ AMM Angle: Use the touch screen dial-button to rotate the cursor line for Anatomical M. You can select an angle from 0 to 179.

Sweep Speed

Tap Sweep Speed on the touch screen. Allows the user to adjust the sweep speed so that he can view various spectrums in a screen.

Display Format

Tap Display Format on the touch screen. Select either Up/Down, Side by Side, or M Only using the touch screen button.

Display Size

The display size can be changed to a range of values between 30/70, 50/50, 70/30 tapping the relevant button on the touch screen. This option is not enabled if Display Format is set to M Only.

M Mode Map

Used to configure the post curve in M. Select a value between 1 and 12 by using the dial-button.

Steer Angle

Adjust the angle of the ultrasound beam. Steered M line can be selected by rotating Steer Angle dial-button.

SAMSUNG HS60 - Steer Angle - 1

NOTE: The Steer function appears on the soft menu only when a linear probe is used.

SAMSUNG HS60 - Steer Angle - 2

NOTE: For more information on other soft menu options and functions, refer to the '2D Mode' section.

Color Doppler Mode

This mode displays the colored blood flow pattern of the ROI (Region of Interest) within the 2D image. It is appropriate for examining the presence of blood flow, its average speed, and its direction. The 2D Mode image is also shown, allowing the marking and adjustment of the ROI within the entire image.

2D C TGC Scale 1.5 Sensitivity 2 Baseline 0 Power 90 Frame Average 3 Filter 2 Color Map 6 Balance 16 Smoothing 3

[Figure 7.7 Color Doppler Mode – Touch Screen]

SAMSUNG HS60 - Color Doppler Mode - 2

Entering & Exiting C Mode

Press the Color dial-button on the control panel. Press this button again to exit Color Doppler mode and return to 2D mode.

SAMSUNG HS60 - Entering &amp; Exiting C Mode - 1

C Mode Screen

ROI Box

ROI stands for Region of Interest. The ROI Box outlines the area of the 2D image where color (blood flow) information is displayed in Color Doppler Mode.

Use the Change button to reposition or resize the ROI box. Each time you press the Change button, the current state of the ROI box is displayed in the lower middle of the screen.

ROI Position: In this state, the position of the ROI box can be changed. Use the trackball to move and position the ROI Box. ROI Size: In this state, the size of the ROI box can be changed. Use the trackball to move the ROI Box and specify its size.

Color Bar

In Color Doppler mode, the color bar indicates the direction and speed of blood flow. Based on the Baseline at the middle, red indicates the direction and speed of blood flow toward the probe. By contrast, the blue color indicates the direction and speed of blood flow away from the probe.

Adjusting the color bar baseline: Use the Baseline dial-button on the touch screen. If you rotate the Baseline dial-button clockwise, the baseline on the color bar rises.

SAMSUNG HS60 - Color Bar - 1

C Mode Menu

Hide Color

Select C mode to use. If you tap Hide Color on the touch screen, the Color mode image will not be displayed in the Color ROI area, and only the B mode image will be displayed. Tap this button again to cancel the selection and return to Color + B/W mode.

Frequency

Tap Frequency on the touch screen. This enables you to configure the probe's frequency.

The selected frequency is displayed in the title area, allowing you to determine the state of the current frequency easily.

Line Density

Select the density of the scan line. Select Low, Med, or High by tapping the button on the touch screen or using the dial-button.

Selecting High increases the number of scan lines and improves the image resolution. However, the frame rate is reduced.

Invert

Tap Invert on the touch screen. The color bar is inverted each time this button is tapped. When the color bar is inverted, the color displayed on the image is also inverted.

Vel + Var

Tap Vel + Var on the touch screen to turn it on or off. It expresses the blood flow velocity in green on the Color Bar. Vel and Var stand for Velocity and Variance respectively.

SAMSUNG HS60 - Vel + Var - 1

NOTE: Vel + Var feature is available in the following applications and presets:

Cardiac - Adult Echo, Ped Echo, Arotic Arch OB - Fetal Heart ▶ Vascular - Carotid, Arterial, Venous

TDI

Change to TDI mode. TDI stands for Tissue Doppler Imaging.

SAMSUNG HS60 - TDI - 1

NOTE:

This can only be used when the cardiac application is selected in Phased Array Probe. For more information on TDI, refer to 'TDI Mode'.

Auto Gain

Tap Auto Gain on the touch screen to turn it on or off. If it is turned on, the brightness of an image will be adjusted automatically.

SAMSUNG HS60 - Auto Gain - 1

NOTE: Auto Gain is applied only when the mode is live for the Carotid and Arterial presets of the linear probe.

Steer Invert

Tap Steer Invert on the touch screen. Tapping the button inverts the angle of the Sample Volume.

SAMSUNG HS60 - Steer Invert - 1

NOTE: Steer Invert is only enabled when using a linear probe.

Scale

Use by rotating the Scale dial-button on the touch screen. Rotating Scale dial-button clockwise increases the scale, extending the range of blood flow speed. Rotating the dial-button in the counter-clockwise decreases the scale, displaying a narrower range of blood flow speed.

Sensitivity

It enhances sensitivity and accuracy or frame rate of color images.

Adjust the Sensitivity value between 0 and 5 by using the Sensitivity dial-button on the touch screen.

Filter

Select Filter on the touch screen or use the dial-button on the control panel to select a value between 1 and 4.

This is an electric filter to remove the low-frequency doppler signals generated by the movement of blood vessel walls. Adjust the Cutoff Frequency to remove doppler signals whose frequency is lower than the cutoff frequency.

BaseLine

Rotating the dial-button clockwise increases the Baseline. In Color Doppler mode, the color bar indicates the direction and speed of blood flow. Based on the Baseline at the middle, red indicates the direction and speed of blood flow toward the probe. By contrast, the blue color indicates the direction and speed of blood flow away from the probe.

Color Map

Used to configure the post curve in a color image. Select a value between 1 and 12 by using the Color Map dial-button on the touch screen. This can help to display blood flow with greater clarity.

Steer Angle

Adjust the angle of the ultrasound beam. Loss of color information resulting from the angle of the ultrasound beam is minimized. You can adjust the angle of the ultrasound beam by using the Steer Angle dial-button on the touch screen.

SAMSUNG HS60 - Steer Angle - 1

NOTE: The Steer function only appears on the soft menu when a linear probe is used.

Balance

Select a balance value from 0 to 16 by using the Balance dial-button on the touch screen. The range of a color image is adjusted by comparing the gray levels of 2D images with the doppler signal values of color images. When the Balance value increases, the color image also appears in the part where the gray level of a 2D image is high (the bright part), increasing the range of the color image.

Smoothing (Spatial Filter)

Select a smoothing value between 0 and 5 by using the Smoothing dial-button. This allows smoother display of color images.

SAMSUNG HS60 - Smoothing (Spatial Filter) - 1

NOTE: For more information on other touch screen items, refer to the '2D Mode'. (Different values can be selected.)

Power Doppler Mode

This mode displays the color intensity of blood flow within the ROI in the 2D image.

It is appropriate for examining the presence and amount of blood flow. The 2D Mode image is also shown, allowing the marking and adjustment of the ROI within the entire image.

2D PD Hide Color Frequency Line Density < Res > < Med > Dual Live S-Flow Steer Invert TGC Scale 0.8 Sensitivity 3 Steer Angle 0 Power 90 Frame Average 3 Filter 2 Color Map 4 Balance 16 Smoothing 1

[Figure 7.8 Power Doppler Mode - Touch Screen]

SAMSUNG HS60 - Power Doppler Mode - 2

Entering & Exiting PD Mode

Press the PD button on the control panel to enter PD mode. Press this button again. PD Mode will be terminated and the mode will switch to 2D.

SAMSUNG HS60 - Entering &amp; Exiting PD Mode - 1

PD Mode Screen

Color Bar

In PD mode, the color bar displayed varies depending on the Power Doppler mode display method that is in use. The color bar indicates the presence of blood flow and its amount. The top of the color bar is the brightest section, where the amount of blood flow is at its highest.

ROI Box

The ROI (Region of Interest) outlines the area of the 2D image where color (blood flow) information is displayed in Power Doppler Mode.

SAMSUNG HS60 - ROI Box - 1

PD Mode Menu

S-Flow

Tap S-Flow on the touch screen. The direction of the blood flow will be displayed.

Auto Gain

Tap Auto Gain on the touch screen to turn it on or off. If it is turned on, the brightness of an image will be adjusted automatically.

SAMSUNG HS60 - Auto Gain - 1

NOTE: Auto Gain is applied only when the mode is in live for the Carotid and Arterial presets of the linear probe.

SAMSUNG HS60 - Auto Gain - 2

NOTE: The description of touch screen menu items is the same as for 'Color Doppler Mode'.

PW Spectral Doppler Mode

PW stands for Pulse Wave. This mode displays the blood flow speed at a specific blood vessel location within a specific time frame. Distance (depth) information can also be obtained by transmitting pulses over particular time frames.

This mode is useful for measuring low-speed blood flow, such as in the abdomen and peripheral vessels. The 2D Mode image is also shown, allowing the marking and adjustment of an observation area within the entire image.

2D PW Simultaneous Display Format < Up/Down > Invert Sweep Speed < 44 mm/s > Display Size < 50/50 > Threshold < 0 > Auto Calc < Off > Trace Method < Max > Trace Direction < Both > TGC SV Size 2.0 Baseline 0 Doppler Map 11 Chroma Map 3 Sound 50

[Figure 7.9 PW Spectral Doppler Mode - Touch Screen]

SAMSUNG HS60 - PW Spectral Doppler Mode - 2

Entering & Exiting PW Spectral Doppler Mode

Entering PW Spectral Doppler Mode

  1. Press the PW button on the control panel to enter PW Spectral Doppler Mode.
  2. Configure settings relating to Doppler image acquisition on the touch screen.
  3. Press the PW dial-button again to enter PW Spectral Doppler Mode and display the Doppler image on the screen.

Exiting PW Spectral Doppler Mode

Press the PW dial-button while the Doppler image is being displayed. You can also press the 2D dial-button to exit PW Spectral Doppler Mode.

Press the Set button on the control panel to obtain a spectral doppler image.

SAMSUNG HS60 - Exiting PW Spectral Doppler Mode - 1

NOTE: The doppler image can only be obtained in the D Only or Simultaneous states.

PW Spectral Doppler Mode Screen Sample Volume

The Doppler spectrum is displayed when the Sample Volume is located above the blood flow on the 2D image. The size of the Sample Volume is displayed in mm units. Use the trackball to adjust the position of the Sample Volume.

▶ Moving Sample Volume: Use the trackball on the control panel. ▶ Resizing Sample Volume: Using the touch screen: Select the SV Size dial-button on the touch screen. Adjusting Sample Volume Angle: Rotate the Angle dial-button on the control panel to select a value between -80-80 degrees. Press the Angle dial-button to select either -60, 0, or 60 degrees.

Adjusting Doppler Baseline

Adjust the Baseline by rotating the dial-button on the touch screen.

HPRF (High PRF) Function

Adjust the blood flow above the speed limit at a specific depth. The scale is increased; this can only be used in PW Spectral Doppler mode (D Only).

SAMSUNG HS60 - HPRF (High PRF) Function - 1

NOTE: Setup > Imaging > Common > HPRF

Activating HPRF

Increasing the scale at a specific depth to a certain point automatically activates HPRF. The Phantom Gate will appear on the D Line at a position higher than the sample volume. Once HPRF starts, PRF does not increase even if you increase the scale value.

Finishing HPRF

While HPRF is in use, decrease the scale value by one step to finish HPRF. Here, the PRF value becomes the maximum value in the current PW Spectral Doppler mode.

▶ Moving Sample Volume

To move the Sample Volume position in the D Only state, the system calculates PRF values and the Phantom Gate position, and updates them on the PW Spectral Doppler image. HPRF is terminated when HPRF cannot be activated.

When Sample Volume is moved in the 2D Only state, the PRF values don't change.

SAMSUNG HS60 - ▶ Moving Sample Volume - 1

CAUTION:

The Phantom Gate position can be located outside the 2D image area in Zoom Mode. Make sure that sample volume and Phantom Gate are not placed together in the measuring area. If more than two Sample Volumes are located in the vessels, all Doppler components will appear in the spectrum, causing noise.

PW Spectral Doppler Mode Menu

Simultaneous

Tap Simultaneous on the touch screen. Each time you tap the button, the Simultaneous function turns on or off. If the Simultaneous option is turned on, you can view real-time 2D and spectral Doppler images at the same time. If the option is not turned on, however, you will only be able to view the image from one of the modes. The Simultaneous function decreases Doppler PRF, thus decreasing the measurable speed range.

Invert

Tap Invert on the touch screen. Each time the button is tapped, the speed indicator (+/-) for a spectrum is inverted.

Auto Calc

Tap Auto Calc on the touch screen to select Off, Live, or Frozen.

Live setting: The PS, ED, MD, PI, RI, PS/ED, ED/PS, HR, TAmax, and TAmean are calculated after acquiring the Doppler Trace. Frozen setting: The PS, ED, MD, PI, RI, PS/ED, ED/PS, HR, TAmax, and TAmean are calculated when the image is frozen.

Values that are displayed on screen are selected at Setup > Measurement > AutoCalc. For selecting displayed values, refer to the measurement settings in 'Chapter 3. Utilities'.

SAMSUNG HS60 - Auto Calc - 1

CAUTION: The measurements carried out by Auto Trace under Measure and Real Time Automatic Doppler Trace (Automatic Calculator) may be different from each other. This is because the algorithms for these two methods are different. It is recommended that you use Auto Trace under Measure for more accurate measurement.

Tips!

Things to Consider when using Real Time Automatic Doppler Trace

  1. Aliasing occurs because PRF is too low in comparison to the image speed, or the spectrum is clustered around the baseline because PRF is too high.
  2. Peak is indistinctive or intermittent such as in Spectral waveforms for veins.
  3. Meaningful spectrum distinction becomes difficult because Doppler Gain is set too high or too low.
  4. An index is displayed during the transition time after Sample Volume is moved with the trackball.
  5. The major spectral signals are cut off because Doppler Wall Filter is set too high.
  6. Peak Trace is interrupted due to abnormal Doppler noise or artifact, and the heart rate is above approximately 140 bpm.

If any of the above apply, Real Time Automatic Doppler Trace may not produce an accurate trace or results. In addition, during auto calculation, results will not be displayed if the Freeze function is run against inaccurate values.

Threshold

Specify the minimum range of Threshold. It can be adjusted between 0 and 10 by using the touch screen button.

Tips!

Threshold

Threshold is a function to adjust Trace Line in the Auto Trace or Limited Trace. Increase the value to capture a wider area, use a smaller value to make the waveform clearer.

Trace Method

Tap Trace Method on the touch screen. Max or Mean Trace for the selected spectrum is performed. It will not be performed if set to Off.

Trace Direction

Tap Trace Direction on the touch screen. Select the part of the spectrum to calculate with AutoCalc from Both, Above, or Below.

Sound

Adjusts the doppler volume. Select a value between 0 and 100 by rotating the Sound dial-button.

Display Format

Tap Display Format on the touch screen. Select either Up/Down, Side by Side, or Doppler Only by using the button on the touch screen.

Doppler Map

Used to configure the post curve in doppler mode. Select a value between 1 and 12 by using the Doppler Map dial-button on the touch screen.

TDW

Switches to TDW Mode. TDW stands for Tissue Doppler Wave.

SAMSUNG HS60 - TDW - 1

NOTE: This can only be used when the cardiac application is selected in Phased Array Probe.

SAMSUNG HS60 - TDW - 2

NOTE: For more information on other touch screen menu items, refer to '2D Mode' and 'Color Doppler Mode' sections.

CW Spectral Doppler Mode

CW stands for Continuous Wave. This mode displays the blood flow speed and direction at a specific blood vessel location within a specific time frame. Unlike PW Spectral Doppler Mode, it does not provide Sample Volume.

SAMSUNG HS60 - CW Spectral Doppler Mode - 1

NOTE:

CW Spectral Doppler mode is an optional feature of this product. This dial-button can be used with the Phased Array or Static CW probes.

Steered CW Spectral Doppler Mode

This mode can only be used if the Phased Array probe is used. The 2D Mode image is also shown, allowing the marking and adjusting of an observation area within the entire image.

Static CW Spectral Doppler Mode

This mode is only available with a Static CW Probe. The 2D image is not displayed.

SAMSUNG HS60 - Static CW Spectral Doppler Mode - 1

Entering & Exiting CW Spectral Doppler Mode

Entering CW Spectral Doppler Mode

  1. Press the CW button on the control panel to enter CW Spectral Doppler Mode.
  2. Configure settings relating to Doppler image acquisition on the touch screen.
  3. Press the CW dial-button again to enter CW Spectral Doppler Mode and display the Doppler image on the screen.

Exiting CW Spectral Doppler Mode

Press the CW dial-button while the Doppler image is being displayed. You can also press the 2D dial-button to exit CW Spectral Doppler Mode.

SAMSUNG HS60 - Exiting CW Spectral Doppler Mode - 1

CW Spectral Doppler Mode Menu

2D CW Invert Sweep Speed < 44 mm/s > Threshold < 3 > Auto Calc < Off > Trace Method < Max > Trace Direction < Both > TGC Scale 4.2 Baseline 0 Power 90 DR 90 Filter 1 Doppler Map 7 Chroma Map 1 Sound 20

[Figure 7.10 CW Spectral Doppler Mode - Touch Screen]

SAMSUNG HS60 - CW Spectral Doppler Mode Menu - 2

NOTE: The menu for CW Spectral Doppler Mode is identical to that of PW Spectral Doppler Mode.

TDI Mode

SAMSUNG HS60 - TDI Mode - 1

NOTE: Appears on the Soft Menu only when using the phased array probe and the cardiac application.

TDI stands for Tissue Doppler Imaging. It visualizes the movement of rapidly moving tissues such as the heart.

It is available in Color Doppler Mode. In Color Doppler Mode, TDI provides color information for cardiac tissues.

Starting and Ending TDI Mode

In Color Doppler Mode, tap TDI on the touch screen. Pressing the button once more switches the mode from TDI to C.

SAMSUNG HS60 - Starting and Ending TDI Mode - 1

NOTE: For information about the touch screen menu, refer to 'Color Doppler Mode'.

TDW Mode

TDW stands for Tissue Doppler Wave. It visualizes the movement of rapidly moving tissues such as the heart. TDW Mode is available in the PW Spectral Doppler Mode. If it is used in Spectral Doppler Mode along with Color Doppler mode, changes in cardiac tissues over time can be observed.

SAMSUNG HS60 - TDW Mode - 1

NOTE: This can only be used when the cardiac application is selected in Phased Array Probe.

Starting and Ending TDW Mode

Tap TDW on the touch screen in PW Spectral Doppler Mode to run it. Pressing the button once more switches the mode from TDW to PW Spectral Doppler.

SAMSUNG HS60 - Starting and Ending TDW Mode - 1

NOTE: For information about the touch screen menu, refer to the 'PW Spectral Mode' section.

ElastoScan Mode

The elasticity of ROI in a 2D image is shown in color. The 2D Mode image is also shown, allowing the marking and adjustment of the ROI within the scanned image.

SAMSUNG HS60 - ElastoScan Mode - 1

NOTE:

▶ ElastoScan mode is an optional feature of this product. The probes, applications, and presets that support ElastoScan are as follows:

Probe Application Preset
LA3-14ADMSK General
Smallparts Breast, Thyroid
LA4-18BDMSK General
Smallparts Breast, Thyroid
EA2-11BGYN Uterus, Adnexa
Urology Prostate
ER4-9GYN Uterus, Adnexa
Urology Prostate
V5-9GYN Uterus, Adnexa
Urology Prostate
LA3-16AMSK General
Smallparts Breast, Thyroid

This function is not available in E mode. Angle, View Area, ECG

2D ROI Mode Frequency Line Density Pen > Med > Invert Dual Live ElastoScan 0 pixels / 1 pixel TGC Contrast 0 E Gain 50 Persistence Level 85 Color Map 6 Blending Level 50 Enhancement 50

[Figure 7.11 ElastoScan Mode]

SAMSUNG HS60 - NOTE: - 2

ElastoScan

An elastogram is the elasticity imaging of an object, based on continuous ultrasound images. The function that measures the elasticity of an object and converts it to images is called ElastoScan. ElastoScan visualizes the presence of a solid mass or stiffness in tissue.

It is already well known that lesions such as tumors are different from healthy tissue in terms of their stiffness. Up until now, palpation has been used for examination, but this method has certain depth limitations.

EDual Mode

In this mode, the elastogram and the 2D image are displayed together on the screen. It can be selected by tapping Single on the control panel and Dual on the touch screen.

To facilitate comparative observation, the 2D image is shown on the left and an E image is shown on the right.

SAMSUNG HS60 - EDual Mode - 1

NOTE:

For ElastoScan, Wide Dual View is set as default. For details about Wide Dual View setting, refer to Setup > Imaging > Display Settings in the 'Chapter 3. Utilities'.

MSK SAMSUNG General LA3-10A 4.0 cm 22 Hz [3b] Gen Gm 50 DB 126 Map7 FA 5 P 90% [8] Pen Gm 50 Map6 HBO FENO 3 1 2 3 4 ROI Position ROI Size SoundType: 6 EFW Input: 5 EFW Mixture: 6 Exit: 1. Stamps/Press 2. Stamps/Print 3. Stamps/Press Tls 0.18 MI 1.36 2016-06-10 11:26:09 AM Sub

[Figure 7.12 E Dual Mode]

E Single Mode

In E Single Mode, only an E image is displayed in the screen. It can be selected by pressing the Single button on the control panel.

MSK SAMSUNG General LA3-16A 4.0 cm 22 Hz [20] Gen Gn 50 Oil 126 Map 7 FA 5 P 90% [E] Pen Gn 50 Map 6 ROI Position | ROI Size Epo/Print: 8 Sat Exit 1 State/Pent EPO Result: 5 2 State/Pent EPO Measure: 6 3 State/Pent Tls 0.18 MI 1.36 2016-06-10 11:25:13 AM Sat: Holt: 3 4 Image: 0

[Figure 7.13 E Single Mode]

ROI Mode

ROI stands for Region of Interest. In E Mode, the ROI Box represents the area where elasticity information is processed and shown. Tap ROI Mode on the touch screen to turn ROI Mode on or off.

It is important that only the effective tissues are included in the ROI, avoiding ineffective components such as bone and air, to obtain a good elasticity image. If the ratio of effective image is insufficient, no elasticity image can be displayed even when tissues are pressured. To scan the breast, it is best to set the ROI as wide as possible in the lateral direction and to include the subcutaneous layer and muscle in the axial direction to obtain a good-quality elasticity image, but it can be flexible to adjust to the real situation.

You can adjust the position and size of the ROI box by using the Change button on the control panel. Each time the Change button is pressed, the current status of the ROI Box is shown in the User Information area of the screen.

ROI Position: The position of the ROI Box can be changed. Move the ROI Box with the trackball to confirm the new position. ROI Size: The size of the ROI Box can be changed. Resize the ROI Box with the trackball and press the Change button to confirm the new size.

MSK SAMSUNG General LA3-16A 4.0 cm 22 Hz [2D] Gen Gm 50 DS 136 Map7 FA 5 P 90% [8] Pen Gm 50 Map6 HSD0 HSD0 ROI Position ROI Size ScorePrint: 6 Sat: 25 Exit: EFW Result: 5 EFW Measure: 6 1. ScorePrint 2. ScorePrint 3. ScorePrint Image: 0

[Figure 7.14 ROI Mode]

SAMSUNG HS60 - ROI Mode - 2

NOTE: ROI Mode is available in E Single Mode as well as in E Dual Mode.

SAMSUNG HS60 - ROI Mode - 3

Starting and Closing E Mode

In 2D Mode, tap ElastoScan on the touch screen. Press the button again to return to 2D Mode.

SAMSUNG HS60 - Starting and Closing E Mode - 1

E Mode Screen

Color Bar

In E Mode, the color bar indicates the stiffness of a tissue. Regardless of the color, the lower section of the bar indicates that the target area is stiffer than the surrounding tissues, and the upper section indicates that the target area is less stiff than the surrounding tissues.

SAMSUNG HS60 - Color Bar - 1

Compression Guide Bar

The strength and status of compression are shown in different numbers of blocks and colors between Steps 0 and 7. All blocks are empty at Step 0, which appears when the probe is almost stationary, the ROI has insufficient region, or matching between images is poor. Step 1 – Step 2 (in grey) mean inadequate compression, and Step 3 – Step 7 (in blue or green) mean adequate compression; the number of blocks filled represents the number of step level.

SAMSUNG HS60 - Compression Guide Bar - 1

SAMSUNG HS60 - Compression Guide Bar - 2

Performing a Scan

When using E mode, place a probe onto the surface of an area to observe and position the ROI appropriately on a lesion to observe. Then use the probe to periodically compress the region. When the compression guide is supported, refer to this guide to adjust the size of the compression. If the region being examined is quite deep, it is best to increase the compression.

SAMSUNG HS60 - Performing a Scan - 1

Precautions for Scanning

To closely observe the location of the lesion, minimize the movement of tissues.

A breast is a complex organ which consists of lactiferous ducts, lactiferous glands, fatty tissue, fibrous tissue, and chest muscles. An axial movement of the probe may cause an unintended movement of the tissues.

The prostate and the thyroid consist of tissues that are simpler than those of a breast and there are relatively fewer unintended movements.

SAMSUNG HS60 - Precautions for Scanning - 1

E Mode Menu

2D ROI Mode Frequency Pen > Line Density Medium > E Invert Dual Live ElastoScan 0 Scan Options - - TGC Contrast 0 50 Persistence Level 85 Color Map 6 Blending Level 50 Enhancement 50 E Gain

[Figure 7.15 ElastoScan Mode – Touch Screen]

Invert

Tap this button on the touch screen to invert the Color Bar. Inverting the color bar also inverts the color displayed on the image.

Dual Live

The elastogram and the 2D image are displayed together on the screen. Pressing Single on the control panel displays the E image only on the screen.

EGain

Adjust the brightness of the elastogram image. Use the dial-button to select a setting between 0 and 100%.

Persistence Level

Specify the speed of change between frames. Use the dial-button to select a setting between 0 and 100%. Selecting a higher value increases the rate of frame change.

Contrast

Adjust the contrast of the elastogram. Use the dial-button to select a setting between 0 and 100%.

Color Map

Select the color of the elastogram. Select a value between 1 and 6 by using the dial-button on the touch screen. If you change the Color Map, the color bar will also change accordingly.

Blending Level

Select the ratio of Alpha Blending. Use the dial-button to select a setting between 0 and 100%. Setting the value to 0% shows an E image only and setting it to 100% shows a 2D image only.

Enhancement

Adjusts the enhancement of the image. Use the dial-button to select a setting between 0 and 100%. A higher setting provides more clearly defined boundaries, at the expense of increased noise.

SAMSUNG HS60 - Enhancement - 1

E-Strain

This function assists with the examination of breast lesions. It calculates the strain ratio between the area of the suspected lesion (ROI) and normal breast fat and displays the results.

SAMSUNG HS60 - E-Strain - 1

NOTE:

▶ E-Strain is an optional feature of this product. ▶ E-Strain is supported in countries except the USA and Canada. The E-Strain button is only activated on the touch screen when the following conditions are satisfied: – Application: Breast, Thyroid - Freeze state

E-Strain

  1. Press the Freeze button on the control panel and then press the E-Strain button.
  2. Specify the position and size of the ROI in the area of suspected lesion.

- Make sure that the fat tissue is visible at the same level as, or above, the ROI.

- Adjust the size of the ROI by using the trackball and the Change button.

  1. Press the Set button. The calculation is automatically performed and the results will be displayed on the screen.
  2. Target Strain: Mean strain value inside the ROI (supported in all countries except the USA and Canada) – Ref. Strain: Mean strain value of areas considered normal outside the ROI (supported in all countries except the U.S.A. and Canada). – Strain Ratio: Ratio of Strain values (Target Strain/Ref. Strain)

E-Strain Reset

When you tap this button on the touch screen, the E-Strain measurements will be reset.

Combined Mode

In Combined Mode, three different modes are combined, including the default 2D Mode. Note that, in 2D/C Live Mode, only two modes are combined: 2D and Color Doppler Modes.

2D/C/PW Mode

Color Doppler Mode and PW Spectral Doppler Mode are displayed simultaneously.

In Color Doppler Mode, press the PW dial-button on the control panel. Or, in PW Spectral Doppler Mode, press the C dial-button on the control panel.

2D/PD/PW Mode

Power Doppler Mode and PW Spectral Doppler Mode are displayed simultaneously.

In Power Doppler Mode, press the PW dial-button on the control panel. Or, in PW Spectral Doppler Mode, press the PD button on the control panel.

2D/C/CW Mode

Color Doppler Mode and CW Spectral Doppler Mode are displayed simultaneously. This mode is available only with certain probes.

In Color Doppler Mode, press the CW dial-button on the control panel. Or, in CW Spectral Doppler Mode, press the C/Z dial-button on the control panel.

2D/C/M Mode

Color Doppler Mode and M Mode are displayed simultaneously.

2D/TDI/TDW Mode

SAMSUNG HS60 - 2D/TDI/TDW Mode - 1

NOTE: This can only be used when the cardiac application is selected in Phased Array Probe.

TDI Mode and TDW Mode are displayed simultaneously. In PD mode or Color Doppler mode, press the TDI, and then press the PW dial-button.

Dual Live Mode

2D Mode and Color Doppler Mode are displayed simultaneously. In either 2D mode or C mode, select Dual Live on the touch screen.

Changing Combined Mode Format

Changing Trackball State

In Combined Mode, more than two image modes are used at the same time.

Depending on the trackball's state, you can change the position or size of: ROI on the active image; the Sample Volume; M line, etc. Press the Change button on the control panel to change the state of the trackball.

Note that when frozen, you can press the Change button to select the type of Cine image.

Changing the Menu

You can change the menu and touch screen menu items without changing the active image mode. The functions of the buttons on the control panel vary depending on the active image mode.

For example, when the touch screen menu for 2D mode is displayed on the screen in 2D/C/PW mode, you can select another mode from the touch screen menu to switch to that mode.

SAMSUNG HS60 - Changing the Menu - 1

NOTE: For information on optimizing an image in Combined Mode, please refer to 'Basic Mode'.

Multi-Image Mode

The product supports Dual Mode and Quad Mode.

In Multi-Image Mode, an image can be displayed in different combined modes. Button operations in an active area are the same as in Combined Mode.

Dual Mode

Press the L or R button on the control panel.

You can compare two independent images with each other. Each time you press the L or R button, one of the two images is selected. The currently active image mode is indicated by a blue marker at the top of the image. The buttons and menu operate according to the image mode that is currently in use.

To exit from Dual mode, press the 2D dial-button.

MSK SAMSUNG General LA3-16A 4.0 cm 51 Hz [20] Geln Grn 32 DR 126 Map 7 FA 5 P 90% HSN7 HsN7 Volume/Print 4 EPII Result 5 EPII Measure 6 Test Set Test 1. Stave Print 2. Stave Print 3. Stave Print Tis 0.36 MI 1.36 2016-06-10 11:26:55 AM Images 0

[Figure 7.16 Dual Mode]

Quad Mode

Press the Quad button on the control panel to enter Quad Mode.

You can compare four different images at the same time. Each time you tap the Quad or Set button, one of the four images is selected. The currently active image mode is indicated by a blue marker at the top of the image. The buttons and menu operate according to the image mode that is currently in use.

To exit Quad mode, press the Single button or the 2D dial-button on the control panel.

SAMSUNG HS60 - Quad Mode - 1

[Figure 7.17 Quad Mode]

SAMSUNG HS60 - Quad Mode - 2

NOTE: For information on optimizing an image in Multi-image mode, please refer to 'Basic Mode'.

3D/4D Mode

These modes show 3D images of the region being examined. HS50/HS60 provides 3D Mode, 4D Mode (optional) and XI STIC (optional).

SAMSUNG HS60 - 3D/4D Mode - 1

NOTE: Standard probes cannot be used for 3D/4D Modes.

Entering and Exiting 3D/4D Mode

Press the 3D/4D button on the control panel. Press the button again to exit 3D/4D mode and return to 2D mode.

3D/4D Mode Screen

ROI Box

In 3D/4D mode, the ROI box is also referred to as the volume box. The box is used to indicate 3D/4D conversion areas.

You can adjust the position and size of the ROI box by using the Change button on the control panel. Each time the Change button is pressed, the state of the ROI box is displayed in the lower middle part of the screen as follows:

ROI Position: In this state, the position of the ROI box can be changed. You can move the ROI box by using the trackball. ROI Size: In this state, the size of the ROI box can be changed. After resizing the ROI box with the trackball, press the Change button to confirm the new size.

SAMSUNG HS60 - ROI Box - 1

3D Mode

The product uses the 3D probe to provide 3D mode and XI STIC.

OB SAMSUNG Tlb 0.23 MI 1.05 2016-06-16 05:50:27 PM MPR SQ Alta Mix 60:40 Th 40 RD C+ Superficle:Liscio Pointer | MOVE | ROI StoreFirst 4 | Sal | EOE | 1 StoreFirst StoreFirst 5 | Sal | EOE | 2 StoreFirst StoreFirst 6 | Sal | EOE | 3 StoreFirst Images 0

[Figure 7.18 3D Mode]

3D

In this mode, you can obtain 3D images by using a 3D probe.

XI STIC

In this mode, fetal cardiac cycle and STIC volume data can be obtained with 3D probes. For more information, please refer to 'XI STIC' in this chapter.

SAMSUNG HS60 - XI STIC - 1

NOTE: XI STIC is an option of this product.

SAMSUNG HS60 - XI STIC - 2

4D Mode

In 4D Mode, 3D images can be obtained in real time with 3D probes. This mode is also called Live 3D Mode.

SAMSUNG HS60 - 4D Mode - 1

NOTE: 4D Mode is an optional feature of this product.

OB SAMSUNG Tib 0.23 MI 1.00 2016-06-16 05:52:04 PM MPR SQ Alca Mix 40:60 Th 38 BD C+ Superflicie:Lucie MOVE Store/Print 4 Store/Print 5 Store/Print 6 Est Exit 1. Store/Print 2. Store/Print 3. Store/Print Images 0 CAP

[Figure 7.19 4D Mode]

SAMSUNG HS60 - 4D Mode - 3

Acquiring 3D/4D Images

  1. Specify the location and size of the ROI Box as desired.
  2. Set the required parameters in the 3D StandBy screen on the touch screen.

Select the menu tab for 3D/4D mode, and configure in the following order: View Mode → Rendering Preset → Other Items.

  1. Press the Freeze or Set button on the control panel. The system will start acquiring 3D images.
  2. Once 3D image acquisition is complete, the 3D View screen will be shown (if configured to do so).
  3. You can perform diagnosis by optimizing images. Press the 3D/4D button to acquire 3D images again.

Tips!

How to Improve 3D Image Quality

Consider the direction, size and section of the viewpoint as well as the visibility of an object. Before acquiring 3D images, adjust the contrast in 2D Mode. The bigger the ROI box, the slower the rendering speed. Therefore, set an appropriate ROI box size. To see the 3D image of a fetus in frontal view, position the fetal head in the direction of the Direction Mark, putting it in the coronal plane. Then scan the fetus from back to abdomen. To determine surface contour, subjects such as amniotic fluid that do not generate echoes should be insulated with hypo-echoic textures. Once 3D image acquisition is complete, you can adjust the low-threshold level to clean up the image. The general rule is not to adjust High Threshold; set it to the maximum value of 255.

3D Stand By

This screen is displayed on the touch screen when 3D/4D Modes are entered. Set the required parameters to specify how 3D images are acquired.

2D 3D/4D 3D 4D XI STIC Curved ROI MPR MSV Oblique Default Surface Skeleton Brain NT User1 User2 User3 Scan Quality High Volume Angle 65

[Figure 7.20 3D StandBy - Touch Screen]

Select a tab for 3D/4D Modes. Different tabs are displayed on the touch screen depending on the probe currently being used.

SAMSUNG HS60 - Menu Tab - 1

Adjusting 2D Images in 3D/4D Modes

Tap the 2D Menu tab on the touch screen to optimize a 2D image before acquiring the corresponding 3D image.

Once the 2D image is optimized, tap 3D Menu on the touch screen to return to 3D StandBy mode.

View Mode

Select a view mode to use after 3D images are acquired.

3D View

The standard view mode for 3D image review. Press MPR to select.

SAMSUNG HS60 - 3D View - 1

Rendering Preset

Selects a Preset for 3D images. For more information, refer to the preset information contained in the '3D View-MPR Mode' section.

SAMSUNG HS60 - Rendering Preset - 1

Scan Quality

Selects the quality of 3D images. Select Low, Med, or High by tapping the button on the touch screen or using the dial-button.

▶ High: Image quality is high, but the speed of capturing (or rendering) 3D image is low. Med2: Provides better image capturing speed and lower image quality than the High setting. Med1: Provides better image capturing speed and lower image quality than the Med2 setting. Low: Provides the highest 3D image capturing speed and the lowest image quality.

SAMSUNG HS60 - Scan Quality - 1

NOTE: Scan Quality is not available in the XI STIC menu tab.

SAMSUNG HS60 - Scan Quality - 2

Volume Angle

Set the scan angle by tapping the touch screen or using the dial-button. The setting range varies depending on the selected probe.

SAMSUNG HS60 - Volume Angle - 1

NOTE: In XI STIC, set the scan angle between 10° and 60° .

3D View - MPR

This view mode is enabled upon acquisition of images when MPR is selected in 3D StandBy. You can optimize 3D images, perform diagnosis, and take measurements.

SAMSUNG HS60 - 3D View - MPR - 1

Changing View Mode

Select the 3D Menu tab on the touch screen to change the view mode.

The Basics of 3D View Mode

Screen LayoutOB SAMSUNG Tib 0.23 MI 1.05 2016-06-16 05:50:27 PM MPR SQ Alca Mix 80:40 Tib 40 RD C+ Superficial:Liscle ① ② ③ ④ ⑤ Pointer MOVE RD Score/Point 6 Set Est 1 Score/Point Score/Point 5 Store/Point 6 2 Store/Point 3 Store/Point Images: 0 CAP

[Figure 7.21 3D View]

① A Plane: The slice image of the axial section. ② B Plane: The slice image of the sagittal section. ③ C Plane: The slice image of the coronal section. 4 3D Image

5 Trackball state indication: The current state of the trackball is displayed at the bottom of the monitor screen. You can select Pointer, Move, or ROI for trackball. Press the Change button on the control panel to change the trackball state. The trackball state changes sequentially each time the button is pressed.

- Pointer: Re-adjusts the position of ROI Box. Pressing the Pointer button on the control panel switches to Pointer state. You can rotate the ROI box around the image axis by using the pointer while pressing the Set button. Press the Change button again to switch to another state.

- Move: Moves the 3D image with the trackball. The acquired 3D image moves as you move the trackball.

- ROI: You can resize the ROI box with the trackball. The ROI box on the 3D image is resized as you move the trackball.

Touch Screen Layout

Only those buttons that are available in the current mode are enabled.

MPR MSV Oblique VOCAL XI VOCAL Ref. Image A B C C Clear Vision < 2 > Mode Display Format 3D Rotation Init 2D VCT Render 5D Follicle Realistic Vue 5D NT MagiCut Accept ROI Curved ROI 3D Cine Post Processing Render Setup Chroma Preset Select 3D Position 10 Bias 20 Mix 60:40 Th.Low 40 Transparency 100

[Figure 7.22 3D View Menu]

Post Gain

Works independently from 2D Gain, with a separate value. The initial value is 0, but this value can be set to any value from -255 to 255. In 4D mode, Post Gain works during Freeze.

Zooming In to/Out of Images

Turn the Zoom dial-button on the control panel to zoom in to/out of images. The current zoom factor appears at the bottom of the screen.

VCT Zoom

SAMSUNG HS60 - VCT Zoom - 1

NOTE: This option is available with VCT.

After tapping VCT Zoom on the touch screen, press the Zoom dial-button on the control panel to convert it to VCT Zoom function. Turn the dial-button to zoom in to/out of VCT images. The current VCT Zoom factor appears at the bottom of the screen.

Rotating Image around X Axis

Use the M/x dial-button on the control panel.

Rotating Image around Y Axis

Use the PW/y dial-button on the control panel.

Rotating Image around Z Axis

Use the Color/z dial-button on the control panel.

Calculations by Application

SAMSUNG HS60 - Calculations by Application - 1

NOTE:

In the 4D mode, measurements of XI STIC and VOCAL are not available. In MSV mode, measurement is not available if the display format is 2x3 or higher.

Press the Calculator button on the control panel. Measurement methods are identical to those described in 'Chapter 8. Measurements and Calculations'.

Basic Measurement

Press the Calculator button on the control panel. For more information, refer to 'Basic Measurement' in 'Chapter 8. Measurements and Calculations'.

Tap Save on the touch screen to finish saving. To cancel it, press the Exit button on the control panel.

Saving Images

SAMSUNG HS60 - Saving Images - 1

NOTE: If volume data contains both 4D and 3D Cine images, choose either 4D or 3D for saving.

  1. Press the Store/Print mapping button on the control panel. The touch screen will show the 3D Data Save screen.
  2. Specify settings such as Data Type, Save Item, and Volume Format.
  3. Tap Save on the touch screen to finish saving. To cancel it, press the Exit button on the control panel.

Tips!

Volume Data

  1. If volume data contains a Cine image, it is saved at the same time.
  2. If images are saved with volume data, they can be converted to new 3D rendering images with SonoView.

graph TD A["Save"] --> B["Data Type"] B --> C["Image"] B --> D["Volume"] E["Save Item"] --> F["3D Cine"] E --> G["4D Img. Cine"] E --> H["4D Vol. Cine"] I["Volume Format"] --> J["Default"] I --> K["Cartesian"] L["Exit"] --> M["Save"]

[Figure 7.23 3D Data Save]

Printing Images

Go to Set up > Customize > Buttons and customize U1, U2, U3, U4, U5, and U6 buttons as you want.

SAMSUNG HS60 - Printing Images - 1

Mode

Select the display format in which 3D images are presented.

Render

Axial, Sagittal, or Coronal plane images are displayed together with the 3D image.

2D

Axial, Sagittal and Coronal plane images, along with OH (Orientation Help), are displayed on the screen. OH indicates the relative position of the currently selected plane in regard to volume data.

SAMSUNG HS60 - 2D - 1

Tap Single on the touch screen for a more detailed view.

VCT

Axial, Sagittal and Coronal plane images and combinations of them are displayed. Each plane is displayed with a different colored frame. VCT is an abbreviation for Volume CT.

SAMSUNG HS60 - VCT - 1

NOTE: Accept ROI is available in Render. Tap the touch screen to turn it on or off. If it is turned on, ROI is not shown.

SAMSUNG HS60 - VCT - 2

Display Format

You can change the display format by using the touch screen. The display format varies for each mode.

▶ Single: Switches to Full screen. Dual: Switches to 2D/3D screen. Quad: Switches to ROI 3D screen.

SAMSUNG HS60 - Display Format - 1

NOTE: In 2D or VCT mode, only Single or Quad Format can be used.

Ref. Image

Tap the corresponding button on the touch screen to select a reference image from among A, B, and C. The selected image will be highlighted with blue borders.

A: Axial Section B: Sagittal Section C: Coronal Section

OH (Orientation Help)

SAMSUNG HS60 - OH (Orientation Help) - 1

NOTE: This option may be used in 2D and Render.

Tap the corresponding button on the touch screen to turn it on or off. If it is turned on, a 3D image will be displayed along with OH.

ClearVision

ClearVision removes noise from the image and enhances outlines to help show the image more clearly. You can select off or adjust the index between 1 and 5 by tapping the touch screen.

3D Rotation

SAMSUNG HS60 - 3D Rotation - 1

NOTE: Mix, Th.Low, and Transparency are available in Render mode.

Select -90° , 90° , or 180° by tapping the button on the touch screen. The coordinate system rotates based on the current 3D image.

Init

When you tap the touch screen, the position information of the 3D image is initialized.

SAMSUNG HS60 - Init - 1

Mix

Configure the mix of Render modes 1 and 2. Use the dial-button to select a ratio between 0:100(%) and 100:0(%).

SAMSUNG HS60 - Mix - 1

NOTE: For details on Render mode, refer to 'Render Setup' in '3D Utility Menu'.

SAMSUNG HS60 - Mix - 2

Th. Low

Specify the minimum range of Threshold. Use the dial-button to select a value between 0 and 254.

SAMSUNG HS60 - Th. Low - 1

Threshold

This option allows you to adjust the threshold value in order to eliminate unnecessary data from images. As the number increases, cyst elements become more apparent. As the number decreases, bone elements become more apparent.

SAMSUNG HS60 - Threshold - 1

Select

Select Post Curve. Use the dial-button to select 2D, 3D, 2D Color, or 3D Color.

SAMSUNG HS60 - Select - 1

Position

Set the position of the post curve selected under Select. Use the dial-button to select a value between 0 and 100.

SAMSUNG HS60 - Position - 1

Bias

Set the bias of the post curve selected under Select. Use the dial-button to select a value between -100 and 100.

SAMSUNG HS60 - Bias - 1

Transparency

Set the transparency of a 3D image. Use the dial-button to select a value between 20 and 250.

The lowest value (20) is for complete transparency, and the highest value (250) is for complete opacity.

HDVI

SAMSUNG HS60 - HDVI - 1

NOTE: HDVI is an optional feature of this product.

Filters 3D images to express outlines more vividly and improve images. Five predefined indices are available.

HDVI Index

Tap HDVI Index on the touch screen. Select an index between 1 and 5 by tapping the button on the touch screen.

HDVI Type

Tap the touchscreen button or use the dial-button to select the part to measure among Face, Brain, Early OB, Heart, Spine, Gyn, Breast, Thyroid, Carotid, Abdomen, Kidney, and Surface and adjust the image.

SAMSUNG HS60 - HDVI Type - 1

NOTE: The ClearVision and HDVI options are enabled in MPR, MSV, Oblique View mode.

SAMSUNG HS60 - HDVI Type - 2

NOTE: The following are enabled in MPR mode: MagiCut, Realistic Vue, 3D Cine, 4D Cine, Render Setup, Preset, Post Processing, Curved ROI, Chroma.

Geometry

Move, magnify, or rotate an image rendered in 3D Mode.

▶ Rotation: Use the X/Y/Z button to rotate the rendered image. Magnification: Use the Zoom button to magnify the rendered image. ▶ Move: Use the trackball to move the rendered image.

5D Follicle

SAMSUNG HS60 - 5D Follicle - 1

NOTE: 5D Follicle is an optional feature of this product.

This feature assists with diagnosis by estimating the size and volume of a follicle in the ovary. Tap this button on the touch screen to switch to the 5D Follicle screen. Press Exit to finish 5D Follicle.

Run 5D Follicle, and the touch screen will switch to the 5D Follicle screen.

  1. Specify the position of scanning. Use the Position dial-button on the touch screen to select between Left Ovary and Right Ovary.
  2. Select a measurement method.

▶ Auto: The follicle is located and measured automatically.

  1. When the measurement is finished, its result is shown on the screen. The scanned parts are color-coded and numbered.

5D Follicle Auto Exit Post Processing Chroma

[Figure 7.24 5D Follicle - Touch Screen]

OB SAMSUNG Tlb 0.24 MI 0.80 2016-06-21 08:33:15 AM MPR SQ High Mix 60:40 Tb 40 RD C= Surface:smooth Pointer SonoPrint 6 Sat Ret 1 SonoPrint SonoPrint 5 Sat Ret 2 SonoPrint SonoPrint 6 Sat Ret 3 SonoPrint Images:0

[Figure 7.25.5D Follicle]

VOCAL

Measure the volume of tissues within the human body. VOCAL is an abbreviation for Virtual Organ Computer Aided anaLysis.

VOCAL can be performed in the following order: VOCAL Define → VOCAL Edit → VOCAL

OB VOCAL SQ Alta Spenco 1/6 SAMSUNG Tib 0.24 MI 1.01 2016-06-16 05:57:48 PM Pointer Store/Print 4 Store/Print 3 Store/Print 6 Est Eat 1 Store/Print 2 Store/Print 3 Store/Print Image: 0

[Figure 7.26 VOCAL]

VOCAL Define

Specify the settings required for VOCAL execution.

SAMSUNG HS60 - VOCAL Define - 1

Contour Type

Select the contour line type. A contour line is automatically created for all types except Manual.

Solid

Used for object data with many echoes.

General

Draw a contour line based on a typical object. This is faster than other automatic contour types but less accurate.

Prostate

Used for prostate data.

Cystic

Used for object data with fewer echoes.

Sphere

After creating a spherical object, edit its contour to make it into the desired shape.

Manual

Create the desired shape of an object manually.

SAMSUNG HS60 - Manual - 1

Ref. Image

Tap the corresponding button on the touch screen to select a reference image from among A, B, and C. The selected image will be highlighted with blue borders.

SAMSUNG HS60 - Ref. Image - 1

Step Angle

Set the rotation angle. Select 12, 18 or 30 by tapping the corresponding button on the touch screen.

SAMSUNG HS60 - Step Angle - 1

Moving Pole Points by Using the Trackball

Set the range to perform VOCAL in a reference image. In a reference image, Pole 1 indicates the position of the upper arrow and Pole 2 indicates the position of the lower arrow. Adjust by using either the trackball and Set button on the control panel or the dial-button on the touch screen.

SAMSUNG HS60 - Moving Pole Points by Using the Trackball - 1

Init

When you tap the touch screen, the position information of the 3D image is initialized.

SAMSUNG HS60 - Init - 1

Next

Tap the touch screen to begin creation of VOCAL data.

SAMSUNG HS60 - Next - 1

When Contour Type is set to Manual

  1. Tap Next on the touch screen. The Image Position screen will be displayed on the touch screen.
  2. After tapping the Set button over an image, move the trackball to contour.

Tap Next to move to the next frame. Tap Previous to move to the previous frame.

  1. Tap Done on the touch screen. Start VOCAL.

If you tap Done without contouring, VOCAL is performed over a sphere.

MPR MSV Oblique VOCAL XI VOCAL Ref. Image A B Init C Step Angle 12° 18° 30° Contour Type Solid General Prostate Cystic Sphere Manual Next Pole1 100 Pole2 240

[Figure 7.27 VOCAL Define - Touch Screen]

VOCAL Edit

Once VOCAL data is created, volume information will be displayed on the screen. In VOCAL Edit Mode, you can modify or redo the existing contour lines.

SAMSUNG HS60 - VOCAL Edit - 1

Shell Mode

Set the shell of an object based on its contour line.

Off

Do not use Shell Mode. The created contour and the shell overlap.

Inside

The shell is drawn inside the contour generated by the specified Shell Thick.

Outside

The shell is drawn outside the contour generated by the specified Shell Thick.

Symmetric

Half the shell is drawn inside the contour and the other half is drawn outside the contour, with each drawn at half of the specified Shell Thick.

SAMSUNG HS60 - Symmetric - 1

Shell Thick.

Set the shell thickness of an object. Use the dial-button to select a value between 1 and 20mm. This option appears on the touch screen only when Shell Mode is used.

SAMSUNG HS60 - Shell Thick. - 1

Image Position

Review contour lines for each frame. Use Previous and Next to move through frames.

SAMSUNG HS60 - Image Position - 1

Multi Edit

Modify more than one contour line at once. Tap this button on the touch screen to turn this feature on or off. If it is turned on, up to 6 contour lines can be displayed simultaneously on the screen. When there are more than 6 lines, use the MEV Page dial-button to navigate through pages. MEV is an abbreviation for Multi Edit View.

Use Pole 1 and Pole 2 to edit contour lines. You can also use the trackball and the Set button on the control panel to edit contour lines. Once editing is complete, tap Exit Multi Edit again to turn it off.

SAMSUNG HS60 - Multi Edit - 1

Clear Contour

When you tap this button on the touch screen, the VOCAL data are deleted, the settings are maintained, and the system returns to the VOCAL Define step.

SAMSUNG HS60 - Clear Contour - 1

New Contour

Tap the button on the touch screen to move from VOCAL Manual page to VOCAL Setup page. This button only appears if Contour Type is set to Manual.

SAMSUNG HS60 - New Contour - 1

Accept Contour

Tap the button on the touch screen to apply changes. The screen will switch to the VOCAL data review screen.

MPR MSV Oblique VOCAL XI VOCAL Shell Mode Off Inside Outside Symmetric Multi Edit Clear Contour Image Position Previous Next Accept Contour

[Figure 7.28 VOCAL Edit – Touch Screen]

VOCAL

Optimizes VOCAL data for review.

SAMSUNG HS60 - VOCAL - 1

VOCAL Mode

Specify how VOCAL data are presented.

ROI 3D

Shows images in the Axial, Sagittal and Coronal planes, together with VOCAL data.

Fixed 3D

Shows images in the Axial, Sagittal and Coronal planes, together with 3D images for VOCAL data.

VCT

Shows actual combinations of images in the Axial, Sagittal and Coronal planes and VOCAL data. Use the VCT Type dial-button to select one from Type 1-Type 8.

SAMSUNG HS60 - VCT - 1

Display Format

When you tap this button on the touch screen and select Single or Quad, the VOCAL data are displayed in full screen. This can be used in every mode. When you press this button again, the display returns to the previous screen.

SAMSUNG HS60 - Display Format - 1

Ref. Image

Tap the corresponding button on the touch screen to select a reference image from among A, B, and C. The selected image will be highlighted with blue borders.

SAMSUNG HS60 - Ref. Image - 1

VOCAL Edit

Tap the corresponding button on the touch screen to return to the VOCAL Edit stage.

SAMSUNG HS60 - VOCAL Edit - 1

Init

When you tap the touch screen, the position information of the 3D image is initialized.

SAMSUNG HS60 - Init - 1

Mode

SAMSUNG HS60 - Mode - 1

NOTE: This option is available with ROI 3D.

Specify how the surface of VOCAL data is presented. Use the dial-button to select Surface or Wireframe.

Surface: VOCAL data are represented using the method of expressing the exterior of images by curves. ▶ Wireframe: VOCAL data are represented by dots and lines.

MPR MSV Oblique VOCAL XI VOCAL Def Image A B Init ROI 3D C VCT Fixed 3D VOCAL Edit Chroma Mode Surface

[Figure 7.29 VOCAL - Touch Screen]

3D XI

SAMSUNG HS60 - 3D XI - 1

NOTE:

3D XI is an optional feature of this product. 3D XI is available only when 3D probes are used.

This view mode is enabled if 3D image acquisition is completed when MSV or Oblique View is selected in 3D StandBy. An image can be viewed in multiple slices.

MSV

An image can be viewed in multiple slices. MSV is an abbreviation for Multi-Slice View.

OB SAMSUNG Tib 0.24 MI 1.01 2016-06-16 06:04:28 PM MSV SQ Altia 0.5 mm RF, A 20.5mm /20% 20.5mm /20% 20.5mm /20% 40.5mm /20% 40.5mm /20% 40.5mm /20% 41.5mm /20% 41.5mm /20% 41.5mm /20% MOVE StonePrint 4 StonePrint 5 StonePrint 6 1 StonePrint 2 StonePrint 3 StonePrint Images: 3

[Figure 7.30 Multi Slice View]

SAMSUNG HS60 - MSV - 2

NOTE: Available options are Calculator, Caliper, Text and Arrow.

SAMSUNG HS60 - MSV - 3

MSV Screen

The images sliced at the thickness set in Slice Thick. are displayed on the screen. Slice Number/Total Number of Slices is shown at the bottom of each slice image. The currently selected slice image is indicated by a blue contour.

The image information displays the current mode, Ref. Image, and Slice Thick.

Rotating Image

Rotating the reference plane affects all other planes.

X-axis Rotation: Use the M/X dial-button on the control panel. If the trackball is in Pointer mode, place the Pointer near the X-axis in an image and then move the trackball while pressing the Set button. Y-axis Rotation: Use the PW/Y dial-button on the control panel. If the trackball is in Pointer mode, place the Pointer near the Y-axis in an image and then move the trackball while pressing the Set button. Z-axis Rotation: Use the Color/Z dial-button on the control panel. If the trackball is in Pointer mode, place the Pointer near the Z-axis in an image and then move the trackball while pressing the Set button.

Moving Image

Set the trackball in Move Mode, and then move it up/down/left/right. The image will move along the X and Y axes.

MPR MSV Oblique VOCAL XI VOCAL Ref.Image A B Init Clear Vision < 2 > Display Format Page Orientation Dot Post Processing Chroma Preset Select 2D Position 50 Bias 0 Selected Slice 77 Slice Thick. 0.5 Ruler None

[Figure 7.31 Multi Slice View – Touch Screen]

Display Format

Set the layout of slice images. Select from 1*1, 2*1, 2*2, 3*2, 3*3, or 4*3 by tapping the corresponding button on the touch screen. The number of indices that can be displayed simultaneously on the screen varies depending on this setting. If the layout is changed, the selected slice image moves to the first position on the screen.

Ref. Image

Tap the corresponding button on the touch screen to select a reference image from among A, B, and C.

MSV OH

Tap the ON button on the touch screen to turn it on or off. If this function is turned on, the A, B, and C planes of the selected slice image will be displayed on the screen. The selected slice and reference images will be highlighted with blue borders.

ClearVision

ClearVision removes noise from the image and enhances outlines to help show the image more clearly. You can select off or adjust the index between 1 and 5 by tapping the touch screen.

Page

Change the page on the screen. This option can be useful when the total number of slice images exceeds what is specified in Display Format. Select a page by tapping the Previous and Next buttons on the touch screen.

Selected Slice

Select a slice image to observe. Use the dial-button to select an Index. The selected index will be highlighted with blue borders.

SAMSUNG HS60 - Selected Slice - 1

Slice Thick.

SAMSUNG HS60 - Slice Thick. - 1

NOTE: The Slice Thick. represents the slice width in volume data, rather than the actual anatomical position.

Set the cut depth of images. Use the dial-button to select 0.5, 1.0, 2.0, 3.0, 4.0, 5.0, or 10.0mm. Depending on your selection, the number of indices and pages will vary.

SAMSUNG HS60 - Slice Thick. - 2

Position

Set the position of the post curve. Use the dial-button to select a value between 0 and 100.

SAMSUNG HS60 - Position - 1

Bias

Set the bias of the post curve. Use the dial-button to select a value between -100 and 100.

SAMSUNG HS60 - Bias - 1

Ruler

Set the position of the ruler. Use the dial-button to select None, Right, Left, Top, Bottom or All.

SAMSUNG HS60 - Ruler - 1

Select

Select Post Curve. Use the dial-button to select 2D or 2D Color.

SAMSUNG HS60 - Select - 1

NOTE:

The following 3D Utility Menu items are enabled in MSV mode: Orientation Dot, Chroma, 4D Cine, Post Processing, Preset

For more information on 3D Utility, see '3D Utility Menu'.

Oblique View

After drawing a straight or curved line in the selected image in MSV Mode, you can study the related oblique image. To do this, follow the procedure below:

  1. Select Display Format and then specify the number of oblique images to study.
  2. Set the Cut Type.
  3. Draw a straight or curved line in a reference image by using the trackball and the Set button. An oblique image will appear with the start (S) and end (E) points shown.

If the trackball is in Move state, the position of the line can be changed.

  1. Optimize the image for observation by using other buttons on the touch screen.

SAMSUNG HS60 - Oblique View - 1

NOTE:

Functions such as Text and Arrow can be used. When Display Format is 2*1, measurement functions such as Calculator and Caliper can be used.

OB SAMSUNG Tib 0.24 Mt 1.01 2016-06-16 06:05:35 PM Oblique SQ Alta Lines RIF, A S1 E1 24 lines 7/18/20 Pointer SonoPrint: 0 Sat 1 SonoPrint SonoPrint: 5 End 2 SonoPrint SonoPrint: 0 3 SonoPrint Images: 0 CAP

[Figure 7.32 Oblique View]

SAMSUNG HS60 - NOTE: - 2

Oblique View Screen

The reference image that is selected in MSV Mode is displayed on the screen. The reference image is highlighted with blue borders and always placed in the top left corner of the screen.

When more than one line is used for observation, each line is indicated by a different color and number.

The image information displays the current mode, Ref.Image, Oblique Cut Type, and Plumb Size (or Slice Thick.).

SAMSUNG HS60 - Oblique View Screen - 1

NOTE: When OVIX is used, the image information also displays OVIX Line Offset, Mix, Threshold Low, and Render Mode 1, 2.

SAMSUNG HS60 - Oblique View Screen - 2

Direction of View of Oblique Image

The observer is located perpendicular to the section of a reference image. Please see the view direction below:

View Direction End point Start point

Start point End point View Direction

SAMSUNG HS60 - Direction of View of Oblique Image - 3

Display Format

Set the layout of oblique images. Select 2*1, 3*2 or 3*3 by tapping the corresponding button on the touch screen. Depending on this setting, the number of oblique images and the Oblique Cut Type will vary.

SAMSUNG HS60 - Display Format - 1

Cut Type

Specify how images are cut by tapping the corresponding button on the touch screen.

Line

The oblique image of a straight line can be studied.

Contour

The oblique image of a curved line or contour line can be studied.

Tips!

Multi Line & Multi Contour

If Display Format is set to 3*2 or 3*3, enable Auto Increment to draw more than one line.

Parallel

SAMSUNG HS60 - Parallel - 1

NOTE: This cannot be used when Display Format is 2*1.

The oblique image of a straight line and its parallel lines can be studied. If a straight line is drawn, its parallel lines are automatically shown on the screen.

Plumb

SAMSUNG HS60 - Plumb - 1

NOTE: This cannot be used when Display Format is 2*1.

The oblique image of a straight line and its perpendicular lines can be observed. If a straight line is drawn, its perpendicular lines are automatically shown on the screen.

ClearVision

ClearVision removes noise from the image and enhances outlines to help show the image more clearly. You can select off or adjust the index between 1 and 5 by tapping the touch screen.

SAMSUNG HS60 - ClearVision - 1

Image Rotation

Specify the direction of an oblique image. Select 90°, 180° or -90°, by tapping the button on the screen. Select the oblique image that you wish to change the direction of from Selected Slice.

SAMSUNG HS60 - Image Rotation - 1

Clear Line

Tap the touch screen to delete an oblique image.

SAMSUNG HS60 - Clear Line - 1

Selected Slice

SAMSUNG HS60 - Selected Slice - 1

NOTE: This cannot be used when Display Format is 2*1.

Use the dial-button to select a line. The oblique image of the selected line is indicated by white contour.

SAMSUNG HS60 - Selected Slice - 2

Plumb Size

SAMSUNG HS60 - Plumb Size - 1

NOTE: This is used only when Cut Type is Plumb.

Use the dial-button to adjust the length of the perpendicular line. The length of the centermost line may be adjusted by 1mm; its current length is displayed in image information.

SAMSUNG HS60 - Plumb Size - 2

Slice Thick.

SAMSUNG HS60 - Slice Thick. - 1

NOTE: This is used only when Oblique Cut Type is Parallel.

Use the dial-button to adjust the interval between the perpendicular lines. The length of the centermost line may be adjusted by 1 mm; its current length is displayed in image information.

SAMSUNG HS60 - Slice Thick. - 2

Rotate Line

SAMSUNG HS60 - Rotate Line - 1

NOTE: This cannot be used when:

▶ Cut Type is Contour; or when the Selected Slice is Selected Slice Select All.

Use the dial-button to rotate a line. When the line is rotated, the oblique image is also changed accordingly.

SAMSUNG HS60 - Rotate Line - 2

OVIX

SAMSUNG HS60 - OVIX - 1

NOTE: This cannot be used when Cut Type is Contour.

OVIX is the abbreviation for Oblique View eXtended, which sets the cross-sectional thickness of an oblique image and shows the image in 3D.

Tap the corresponding button on the touch screen to turn it on or off. When this is on, an OVIX Line appears in the reference image, which indicates the cross-sectional thickness of the oblique image of the reference image.

The thickness of the OVIX Line can be adjusted with OVIX Thick. To change the 3D image settings, select and adjust Setting or OVIX Post Curve from the 3D Utility Menu.

SAMSUNG HS60 - OVIX - 2

OVIX Thick.

Use the dial-button to adjust the thickness of OVIX. The 3D image for the set thickness appears.

SAMSUNG HS60 - OVIX Thick. - 1

Select

Select Post Curve. Use the dial-button to select 2D, OVIX, 2D Color, or OVIX Color.

SAMSUNG HS60 - Select - 1

Init

Tap the touch screen to delete the Oblique image and reset the position information for Ref. Image.

SAMSUNG HS60 - Init - 1

NOTE: The following 3D utility menu items are enabled in Oblique View mode: Orientation Dot, 4D Cine, Post Processing, Render Setup, Chroma, Preset

For more information on 3D Utility, refer to '3D Utility Menu'.

MPR MSV Oblique VOCAL XI VOCAL Cut Type Line Contour Init Auto Increment Clear Line OVIX Display Format Image Rotation Clear Vision 2 > Orientation Dot Post Processing Chroma Preset Select 2D Position 50 Bias 0 Rotate Line

[Figure 7.33 Oblique View - Touch Screen]

XI VOCAL

SAMSUNG HS60 - XI VOCAL - 1

NOTE: XI VOCAL is one of the 3D XI features. It is available as an optional feature of this product.

Measure the volume of tissues in 3D XI Mode.

OB SAMSUNG Tib 0.24 MI 1.01 2016-06-16 06:06:24 PM XI VOCAL SQ Alta 1/7 VS VS VS RS RS RS RS RS RS RS RS RS RS RS RS RS RS RS RS RS RS RS RS RS RS RS RS RS RS RS RS RS RS RS RS RS RS RS RS RS RS RS RS RS RS RS RS RS RS RS RS RS RS Ratience Value : 10.000 (x1) Pointer SoreXFlex 4 Sat 1 RR 1 SoreXFlex…

[Figure 7.34 XI VOCAL]

SAMSUNG HS60 - XI VOCAL - 3

VOCAL vs XI VOCAL

▶ VOCAL: Measures the volume of an object in a general 3D image. Uses rotating slices. XI VOCAL: Measures the volume of an object in the selected reference image in MSV Mode by using parallel slices. Uses parallel slices. Calculates the volume of an object by cutting it into multiple slices.

XI VOCAL is performed in the following order: XI VOCAL Define → XI VOCAL Edit → XI VOCAL

XI VOCAL Define

Specify how slice and contour lines are extracted.

Reference images and slice lines are displayed on the left side of the screen. Slice images with the start (S) and end (E) points of a slice line are displayed on the right side of the screen.

OB X1 VOCAL SQ AEA REF. A Manual 5 SAMSUNG Tib 0.24 MI 1.01 2016-06-16 06:06:52 PM Start End Volume: 23.00mm Unreal: 5.917mm MOVE Stave/Point 4 Stave/Point 8 Stave/Point 6 Exit 1 Stave/Point Exit 2 Stave/Point Exit 3 Stave/Point Image 0 CAP

[Figure 7.35 XI VOCAL Define]

Contour Type

Select the contour line type. A contour line is automatically created for all types except Manual.

Solid

Used for object data with many echoes.

Cystic

Used for object data with fewer echoes.

General

Draw a contour line based on a typical object. This is faster than other automatic contour types but less accurate.

Manual

Create the desired shape of an object manually. A contour line can be specified in the XI VOCAL Edit screen.

SAMSUNG HS60 - Manual - 1

Ref. Image

Tap the corresponding button on the touch screen to select a reference image from among A, B, and C. The selected image will be highlighted with blue borders.

Ref. Contour

Tap this button on the touch screen to turn this feature on or off. If it is turned on, a contour line can be drawn by using the trackball and the Set button.

SAMSUNG HS60 - Ref. Contour - 1

Slice Direction

Set the direction of a slice line. Select from Vertical or Horizontal by tapping the corresponding button on the touch screen. Changing the direction of a slice line also changes the slice image displayed on the screen.

SAMSUNG HS60 - Slice Direction - 1

Init

When you tap the touch screen, the position information of the 3D image is initialized.

SAMSUNG HS60 - Init - 1

Next

Tap the touch screen to switch to the XI VOCAL Edit screen.

SAMSUNG HS60 - Next - 1

NOTE: If Contour Type is set to Manual, the system switches to the XI VOCAL screen when Next is pressed.

SAMSUNG HS60 - Next - 2

# of Slices

Specify the number of slice images. Use the dial-button to select 5, 10, 15, or 20. Depending on the selected number of images, the interval between slices will vary.

MPR MSV Oblique VOCAL XI VOCAL Ref Image A B Init C Ref. Contour Slice Direction Contour Type Solid Cystic General Manual Next of Slices 5

[Figure 7.36 XI VOCAL Define - Touch Screen]

XI VOCAL Edit

Specify the contour extraction range or run XI VOCAL.

Based on slice lines, slice images and pole points will be displayed on the screen. A pole point is a reference point against which an object contour is extracted. Two pole points appear in each slice image.

The selected slice image is highlighted with blue borders. 'The image number/the total number of slice images' is shown at the bottom of each image.

Tips!

Reference Image and Slice Line

These always appear in the bottom right corner of the XI VOCAL Edit screen. They can be useful when the position of a slice image needs to be considered.

OB SAMSUNG Tib 0.24 MI 1.01 2016-06-15 08:07:23 PM XI VOCAL SQ Alta 1/1 4%

[Figure 7.37 XI VOCAL Edit]

Ref. Page

Use the dial-button to change the screen page.

New Contour

Tap the corresponding button on the touch screen to delete the current data and return to the XI VOCAL Define stage.

SAMSUNG HS60 - New Contour - 1

Accept Contour

Tap the button on the touch screen to apply changes and run XI VOCAL. The system will switch to the XI VOCAL screen.

SAMSUNG HS60 - Accept Contour - 1

When Contour Type is set to Manual

Use the Set button and the trackball to draw a contour line before pressing Accept Contour. If you press Accept Contour without drawing a contour line, a general type contour line will be extracted.

MPR MSV Oblique VOCAL XI VOCAL Edit Contour New Contour View All Slice Accept Contour TGC Pole1 119 Pole2 277 Ref.Page 1/1

[Figure 7.38 XI VOCAL Edit – Touch Screen]

XI VOCAL

Optimize XI VOCAL data for review.

Slice images with their contour line shown and 3D reference images are displayed. The 3D reference image is highlighted with blue borders, and the calculated volume is shown at the bottom of the image.

SAMSUNG HS60 - XI VOCAL - 1

3D Reference Image

Use XI VOCAL to display an object for which volume has been obtained in 3D. Use the Zoom, M/x, PW/y or Color/z dial-buttons on the control panel to zoom or rotate for observation.

SAMSUNG HS60 - 3D Reference Image - 1

View All Slices

Tap this button on the touch screen to turn this feature on or off. If it is turned on, all XI VOCAL data – including reference image, slice line and slice image – will be displayed simultaneously on the screen.

SAMSUNG HS60 - View All Slices - 1

Edit Contour

Tap the touch screen to return to the XI VOCAL Edit screen. You can edit the contour line by using the trackball and the Set button.

MPR MSV Oblique VOCAL XI VOCAL Edit Contour New Contour View All Slice TGC Ref.Page 1/1

[Figure 7.39 XI VOCAL – Touch Screen]

XI STIC

SAMSUNG HS60 - XI STIC - 1

NOTE:

XI STIC is an optional feature of this product. XI STIC is only available when 3D probes are used. This only appears when the Application is set to OB. When you enter 3D Standby in Fetal Heart Preset, the system will automatically switch to STIC.

This option can be used to obtain the fetal cardiac cycle with volume data on the fetal cardiac area, and to recompile the volume data for display. STIC is an abbreviation for Spatio-Temporal Image Correlation.

OB SAMSUNG Tib 0.24 MI 1.01 2016-06-16 06:09:21 PM MPR Mix 25/75 TB 60 RD A+ Superficle/Liacto XI STIC Heart Rate 153 Scan Time 10s Img. Angle 37.5° Val. Angle 20.0° Vol.Index 40x40 MOVE SOI StorePrint 4 StorePrint 5 StorePrint 6 1. StorePrint 2. StorePrint 3. StorePrint Images 8 CAP

[Figure 7.40 XI STIC]

Acquiring XI STIC Images

SAMSUNG HS60 - Acquiring XI STIC Images - 1

NOTE: If the motion artifacting is severe, data does not contain the cardiac cycle, or the heart rate cannot be calculated for any other reason, you will be returned to the XI STIC image preparation screen.

  1. Select the XI STIC tab in the 3D Stand By screen on the touch screen.
  2. Set the various parameters as you would for acquisition of standard 3D images.
  3. Press the Freeze or Set button on the control panel. The system will begin acquiring 3D images.
  4. When image acquisition is complete, XI STIC is displayed on the monitor screen and the XI STIC Confirm screen appears on the touch screen. Check the fetal cardiac cycle calculated.
  5. Tap Yes on the touch screen to continue. Tap No to cancel and acquire the images again.
  6. You can perform diagnosis by optimizing images.

Tips!

To Obtain Superior STIC Volume Data

Volume Angle: If the size of the fetal heart is small, use a smaller Volume Angle. ROI Position: Adjust the scan position so that the center of the Volume Angle and the fetal heart are aligned properly. ROI Box: Adjust the size of the volume box so that it nearly fits the size of the fetal heart.

SAMSUNG HS60 - To Obtain Superior STIC Volume Data - 1

Volume Angle

Set the scan angle. Select a value between 10 and 60 by using the dial-button.

SAMSUNG HS60 - Volume Angle - 1

Scan Time

Set the image acquisition time. Use the dial-button to select between 7 and 15 seconds.

SAMSUNG HS60 - Scan Time - 1

Trimester

Set the pregnancy trimester. Use the dial-button to select 1st, 2nd, or 3rd.

SAMSUNG HS60 - Trimester - 1

Trimester

If the 1st to 3rd trimesters are selected, the recommended scan time and STIC angle are automatically set for the specified trimester. Please see the following table:

Trimester 1st 2nd 3rd
Scan Time 10 seconds12 seconds 15 seconds
Volume Angle 20° 25° 30°

If a scan time and Volume Angle other than those in the above table are set, the trimester is displayed as User Set.

SAMSUNG HS60 - Trimester - 1

NOTE: For information on other usage, please refer to the "3D Stand By" section.

Reviewing XI STIC Image

XI STIC image is played as a Volume Cine; on the left side of the screen, XI STIC information including HR, Scan Time, Img. Angle, Vol. Angle, and Volume Index are displayed.

SAMSUNG HS60 - Reviewing XI STIC Image - 1

NOTE: During Volume Cine, only MPR, MSV, and Oblique View Modes are available.

Press the Freeze button on the control panel to stop Volume Cine playback.

Speed

Select the playback speed for XI STIC images. Use the dial-button to select Very Slow, Slow, Normal, Fast, or Fastest. This rate is based on the fetal heart rate (100%).

Vol. Index

Use the dial-button to select an Index.

SAMSUNG HS60 - Vol. Index - 1

NOTE:

This option is only available when Freeze is enabled. Refer to 3D View-MPR and 3D XI for further information on its use.

MPR MSV Oblique Ref Image A B Init 2D C OH Clear Vision < Off > Mode Display Format 3D Rotation Realistic Vue MagiCut Accept ROI Post Processing Render Setup Chroma Preset Select 3D Position 60 Bias 30 Mix 25:75 Th.Low 60 Speed Normal Transparency 70

[Figure 7.41 XI STIC - Touch Screen]

4D

SAMSUNG HS60 - 4D - 1

NOTE:

4D Mode is an optional feature of this product. ▶ 4D Mode is available only when 3D probes are used.

In 4D Mode, 3D images can be obtained in real time with 3D probes. This mode is also called Live 3D Mode.

Images can be acquired in the same way as for standard 3D images.

SAMSUNG HS60 - NOTE: - 1

4D Mode Screen

Press the Freeze button on the control panel to switch to the 4D Cine screen.

SAMSUNG HS60 - 4D Mode Screen - 1

NOTE: In 4D state, only MPR, MSV, and Oblique View modes are available. For more information, see 3D View-MPR and 3D XI.

3D Utility Menu

SAMSUNG HS60 - 3D Utility Menu - 1

3D Cine

The 3D images saved temporarily in the system can be reviewed. The 3D Cine Define screen is displayed on the touch screen.

3D Cine Define

Specify the settings needed for creation of a Cine image.

Rotate Angle

Set the overall rotation angle by tapping the corresponding button on the touch screen. Select a value from 30, 45, 60, 90, 180 or 360°.

Step Angle

Set the rotation angle for a single step in an image by tapping the corresponding button on the touch screen. Select a value from 1, 3, 5, or 15 degrees.

SAMSUNG HS60 - Step Angle - 1

The Difference between Rotate Angle and Step Angle

A Cine image rotates to the angle specified under Rotate Angle. During this process, each rotational step is equivalent to the angle specified under Step Angle. For example, if Rotate Angle is set to 360 degrees and Step Angle is set to 15 degrees, a 3D Cine image rotates to 360 degrees in 25 steps, each of which involves a rotation of 15 degrees.

Rotate Axis

Set the rotational axis by tapping the corresponding button on the touch screen.

Generate

Cine images are generated by applying the current settings. Once the images are generated, the touch screen switches to 3D Cine Review.

Review

Review Cine images generated previously. The touch screen switches to 3D Cine Review.

Start Angle

Use the dial-button to set the start angle of a Cine image. When Start Angle is set, Rotate Angle is cancelled.

End Angle

Use the dial-button to set the end angle of a Cine image. When End Angle is set, Rotate Angle is cancelled.

3D Cine Rotate Angle 30° 45° 60° 90° 180° 360° Exit Step Angle 1° 3° 5° 15° Generate Start Angle -22 End Angle 23 Rotate Axis Y

[Figure 7.42 3D Cine Define - Touch Screen]

3D Cine Review

Specify the settings needed for review of a Cine image.

OB SAMSUNG Tib 0.24 MI 1.01 2016-06-15 06:11:08 PM MPR SQ Alta Mix 60:40 Th 40 RD C* SuperFlect:Lucie Cine 3/4 Store/Point 4 Set Exit 1 Store/Point Store/Point 5 Store/Point 6 Store/Point 7 Store/Point Images 0 CAP

[Figure 7.43 3D Cine Review]

Play Mode

Select the play mode for Cine images. Select from Loop or Yoyo by using knob button.

▶ Loop: Repeats playback in one direction. ▶ Yoyo: Plays until the end in one direction, and then plays in the reverse direction.

Cine Play

Tap this button on the touch screen to turn this feature on or off. Cine images are played when this is on. If it is turned off, Cine Frame will appear on the touch screen.

New Cine

Clears the current Cine image and creates a new one. The system switches to the 3D Cine Define screen.

Speed

Use the dial-button to select the playback speed of a Cine image. Select from Very Slow, Slow, Normal, Fast, or Fastest.

Trim Start

After specifying the position of the first frame by using the dial-button, tap the dial-button to save it.

Trim End

After specifying the position of the last frame by using the dial-button, tap the dial-button to save it.

Cine Frame

SAMSUNG HS60 - Cine Frame - 1

NOTE: This option is available when Play is turned off. It can be adjusted by as many as the total number of Cine frames by using the knob button with the 'current Cine frame number' being shown on the monitor screen.

Select a Cine frame to review. Use the dial-button or move the trackball left or right to select.

3D Cine Exit Speed Normal Play Mode Loop Trim Start 1 Cine Frame 2 Trim End

[Figure 7.44 3D Cine Review - Touch Screen]

SAMSUNG HS60 - Cine Frame - 3

MagiCut

SAMSUNG HS60 - MagiCut - 1

NOTE:

▶ Select this in MPR mode. If MagiCut is enabled, Accept ROI is turned on automatically. After MagiCut is enabled, if the system is switched to a mode other than MPR Mode, MagiCut is disabled.

The MagiCut screen is displayed on the touch screen. You can cut the parts that are not relevant to diagnosis away from 3D images. Set the area to cut by using the trackball and the Set button.

Mode

Set how parts are cut by tapping the corresponding button on the touch screen.

▶ Inside Contour: Cuts the inside of the selected area. ▶ Outside Contour: Cuts the outside of the selected area. Inside Box: Cuts the inside of the box. Outside Box: Cuts the outside of the box. ▶ Small Eraser: Cuts the selected contour line. ▶ Big Eraser: Cuts the selected contour line. This uses a thicker contour line than Small Eraser.

Full Depth

Tap the corresponding button on the touch screen to turn Full Depth on or off. If it is turned on, the entire area will be cut. If it is turned off, Depth will appear on the touch screen.

Depth

Set the cut depth. Use the dial-button to select a value between 1 and 100.

Undo

Cancel the previous task(s).

▶ Undo: Cancel the last task. ▶ Undo All: Cancel all tasks that have been done so far.

Mix

Configure the mix of Render modes 1 and 2. Use the dial-button to select a ratio between 0:100(%) and 100:0(%).

Th.Low

Specify the minimum range of Threshold. Use the dial-button to select a value between 0 and 254.

MagiCut Full Depth Exit Inside Contour Outside Contour Inside Box Outside Box Small Eraser Big Eraser Mix 40:60 Th.Low 38

[Figure 7.45 MagiCut – Touch Screen]

SAMSUNG HS60 - Th.Low - 2

Orientation Dot

Tap the corresponding button on the touch screen to turn the Orientation Dot on or off. When this is on, a dot appears at the center of the reference image.

SAMSUNG HS60 - Orientation Dot - 1

Render Setup

SAMSUNG HS60 - Render Setup - 1

NOTE: In Oblique View Mode, this option is available only when OVIX is On.

The Settings screen appears on the touch screen. Specify the image rendering method.

After selecting the rendering mode tab on the touch screen, specify the required settings including Render Direction and Render Mode. The specified settings will be displayed in the image information area.

This product provides four Render modes – Gray, Inversion, Color, and SeeThru.

Gray Render Direction Render Mode 1 Render Mode 2 Inversion Smooth Surface Smooth Light Max Min Max Min X-Ray X-Ray Exit Transparency 100 Mix 40:60 Th.Low 38 Th.High 255

Gray

Specify how volume data acquired with the gray method should be rendered into 3D images.

Render Direction

Set the rendering direction by clicking the corresponding button on the touch screen.

Render Mode 1, 2

Enter Render Modes 1 and 2 by tapping the corresponding buttons on the touch screen.

Surface: Represents 3D images in the Ray-Casting method, which shows the shell of an image with curved surfaces. Smooth: Represents 3D images that are smoother than those created by the Surface method. Max: Represents 3D images at maximum intensity. It can be useful for the observation of bone structures in a human body. Min: Represents 3D images at minimum intensity. It can be useful for observation of vessels or hollow parts in a human body. Light: Represents the depth of 3D images in terms of brightness. X-Ray: Represents 3D images in terms of average intensity. This shows images that are similar to X-ray images.

SAMSUNG HS60 - Render Mode 1, 2 - 1

NOTE: For descriptions of other menu items, see 'Render Setup'.

Mix

Configure the mix of Render modes 1 and 2. Use the dial-button to select a value between 0 and 100.

Th.High

Used to specify the maximum threshold range. Use the dial-button to select a value between 1 and 255.

Th.Low

Specify the minimum range of Threshold. Use the dial-button to select a value between 0 and 254.

SAMSUNG HS60 - Th.Low - 1

Threshold

This option allows you to adjust the threshold value in order to eliminate unnecessary data from images. As the number increases, cyst elements become more apparent. As the number decreases, bone elements become more apparent.

Th.Power

Specify the Threshold for color. Use the dial-button to select a value between 0 and 255. As this value increases, more color is removed from an image.

Color

Specify how the volume data acquired with the Angio/CFM method are rendered into 3D images. Other settings are configured in the same way as Gray Render Mode.

See Thru

Set the method for rendering the data from Gray+Angio, Gray+CFM combinations as a 3D image. Settings other than Render Mode 1 and 2 are configured in the same way as Gray Render Mode.

Transparent-Transparent

Adjust the transparencies of both Gray and Color data, so that the Color data inside the Gray data may be studied. The parts that are obscured by the Gray data are displayed slightly darker.

Transparent-Surface

Adjust the transparency of Gray data, so that the Color data inside the Gray data may be studied. The parts that are obscured by the Gray data are displayed slightly darker.

Max-Transparent

Set Gray data to 'Max', and Color data to 'Transp', to study Color data. The parts that are obscured by the Gray data are displayed slightly lighter.

Max-Surface

Set Gray data to 'Max', and Color data to 'Surface', to study Color data. The parts that are obscured by the Gray data are displayed slightly lighter.

Inversion

This option shows inverted images when the volume data acquired by the gray method is rendered into 3D images. Other settings can be specified in the same way as with Gray Render Mode.

SAMSUNG HS60 - Inversion - 1

Realistic Vue

Semi-translucent rendering is used for a realistic display of fetal images. When you press the Realistic Vue button, Clear SFVI, HDVI, and VC are turned on.

SAMSUNG HS60 - Realistic Vue - 1

NOTE:

Realistic Vue is an optional feature of this product. HDVI is an optional feature of this product and only available for HS60.

Light Direction

Use the touch screen or the trackball to reposition the direction of the light that is applied to volume.

SAMSUNG HS60 - Light Direction - 1

NOTE: You need to press the Move Light button to enter trackball mode.

Set Color

Use the dial-button to select the Set Color applied to Realistic Vue.

SAMSUNG HS60 - Set Color - 1

NOTE: You can set color by using the Hue, Saturation, and Lightness dial-buttons

MPR MSV Oblique VOCAL XI VOCAL Ref.Image A B C OH Clear Vision < 2 > Mode Display Format 3D Rotation 2D VCT Render 5D Follicle Realistic Vue 5D NT MagiCut Accept ROI 3D Cine Ab/Cine Post Processing Render Setup Chroma Preset Select 3D Position 0 Bias 100 Mix 70:30 Th.Low 30 Transparency 250

[Figure 7.47 Realistic Vue - Touch Screen]

SAMSUNG HS60 - Set Color - 3

Chroma

The Chroma Map screen is displayed on the touch screen. Set the color of 2D and 3D images by tapping the corresponding button on the touch screen.

Chroma 2D Chroma Map Map 1 Map 2 Map 3 Map 4 Map 5 Map 6 Map 7 Map 8 Map 9 Map 10 3D Chroma Map Map 1 Map 2 Map 3 Map 4 Map 5 Map 6 Map 7 Map 8 Map 9 Map 10 Exit

[Figure 7.48 Chroma Map - Touch Screen]

SAMSUNG HS60 - Chroma - 2

Post Processing

The Post Processing screen is displayed on the touch screen.

Post Processing Exit Auto Contrast Negative Threshold Sharpen 3D CI Gradient Mask Flip Image

[Figure 7.49 Post Processing – Touch Screen]

Gradient Mask

Adjust the brightness of a specific area in an image. Make a selection by tapping the corresponding button on the touch screen.

Flip Image

Inverts the position of an image.

SAMSUNG HS60 - Flip Image - 1

NOTE: This option is only available in MSV Mode.

Tap the image on the touch screen and flip the image left and right or up and down.

Negative

Tap this button on the touch screen to turn this feature on or off. If it is turned on, the brightness of an image will be inverted.

Auto Contrast

Tap this button on the touch screen to turn this feature on or off. If it is turned on, the contrast of an image will be adjusted automatically.

Threshold

Tap this button on the touch screen to turn this feature on or off. If it is turned on, the Th.Low or Th.High dial-buttons can be used to adjust the threshold.

Sharpen

Tap this button on the touch screen to turn this feature on or off. If it is turned on, the boundary of an image will become more apparent. Select a value between 100 and 400 by using the Sharp dial-button.

3D CI

Tap this button on the touch screen to turn this feature on or off. 3D CI is an abbreviation for 3D Compound Imaging.

If set to On, images are compounded to reduce noise and enhance image quality. Use the 3D CI Offset dial-button to select a value between 1–10 as the distance between images used for 3D CI.

SAMSUNG HS60 - 3D CI - 1

Preset

The Preset screen appears on the touch screen. You can set the currently selected Preset or rename the Rendering Preset. Default is the default value of the system.

Preset Default Surface Skeleton Brain NT User1 User2 User3 Exit Load Rename Save

[Figure 7.50 Preset - Touch Screen]

Default

Use the default setting (General Preset) for the probe.

Load

When you tap this button on the touch screen, the currently selected Preset is applied to the system. Then the Preset screen is closed.

Save

Tap Save. When you tap this button on the touch screen, the current Preset is saved.

Rename

Change the name of the selected Rendering Preset. When you tap this button on the touch screen, the Name screen appears. After changing the name, tap Save to save the changed name. Tap Close to cancel the change.

Reset

When you tap this button on the touch screen, the Preset is reset to its default value.

SAMSUNG HS60 - Reset - 1

4D Cine

The 4D images saved temporarily in the system can be reviewed. The 4D Cine screen is displayed on the touch screen.

SAMSUNG HS60 - 4D Cine - 1

NOTE: You can also press the Freeze button in 4D Mode to execute 4D Cine.

Play Mode

Select the play mode for Cine images. Use the touch screen to select either Loop or Yoyo.

▶ Loop: Repeats playback in one direction. ▶ Yoyo: Plays until the end in one direction, and then plays in the reverse direction.

Cine Type

Select the Cine image type by tapping the corresponding button on the touch screen.

Volume: This button appears when Cine images are played. The MPR, MSV, or Oblique buttons are enabled, depending on the state before the 4D Cine was started. Cine images can be played by changing Display Format, etc. ▶ Image: This is the general Cine playing method.

Cine Play

Volume: Tap the Play button on the touch screen to play; tap the Freeze button to freeze. Image: Tap the Play button on the touch screen to play; tap Play again to freeze.

Cine Speed

Set the speed at which Cine images are played. Use the dial-button to select Very Slow, Slow, Normal, Fast, or Fastest.

Vol.Index

Move the trackball or use the dial-button to select an Index. The current volume data number/total number of volume data is displayed.

4D Cine Cine Type Image Volume Play Mode Loop Yoyo Exit Display Format Speed Normal Trim Start 1 Trim End 38 VolIndex 38/38

[Figure 7.51 4D Cine - Touch Screen]

SAMSUNG HS60 - Vol.Index - 2

5D NT

SAMSUNG HS60 - 5D NT - 1

NOTE:

5D NT is an optional feature of this product. These options are only available in MPR mode.

This feature locates the Mid-Sagittal View and measures the thickness of the nuchal translucency (NT) of the fetus. The 5D NT window appears on the touch screen.

Use the trackball to place NT Seed in NT area, and press the Set button to display the NT measurement on the A Plane.

Tips!

How To get good results

▶ You can get better results when the Sagittal View of the fetus is captured as accurately as possible. The higher the contrast between the fetus's palate and nasal bone, the better. It is preferable to have the lateral direction of the probe be parallel to the body orientation of the fetus. It is preferable to have the probe's angle to the fetus's nasal bone as close to 30 degrees as possible.

NT Caliper Placement

Tap the touch screen to select the NT measurement type.

On to On: Measure by placing the cursor on the NT's inner-inner.

SAMSUNG HS60 - NT Caliper Placement - 1

On to Max Brightness: One side of the cursor is placed on the outside of the NT, and measurement is taken with inner-outer. This method is used when Harmonic is used and one side of the nuchal translucency is blurred.

Cursor

In to In: Similar to On to On, this method takes measurement with inner-inner, albeit with a narrower cursor interval.

Cursor

Items

NT: The acquired A, B, and C plane images and the automatically measured NT are displayed in the 3D View screen. IT: Locates mid-sagittal view and tests the fetus for spina bifida.

Assign

Tap the touch screen to include the selected items in the OB report.

5D NT

This function helps the user to easily see the NT measurement process. This assigns a certain thickness to A, B and C sections of the image and displays 3D Rendering image.

Init

The image's position information is reset.

Hide All

Pressing this button will hide the marker and the measurements for NT and IT from the screen.

Auto

Tap the corresponding button on the touch screen to turn this feature on or off. If set to On, automatically locates Mid-Sagittal View. To calculate NT, place the cursor on NT area and press the Set button on the control panel.

Edit

Edit markers for each item that is displayed as a result.

If the trackball's state is Cursor, move the cursor near a + marker.

Press the Set button and move the trackball to edit the marker as desired.

ROI Height

Use the dial-button to adjust the ROI Line's Height to define the scope of the application. The ROI Height may be adjusted while measurements are being taken or in Edit mode.

Marker Size

Tap on the touch screen or use the dial-button to select Small, Medium, or Large.

Measurements and Calculations

■ Measurement Accuracy.... 8-3

Causes of Measurement Errors 8-3

Optimization of Measurement Accuracy .....8-5

Measurement Accuracy Table 8-7

■ Basic Measurements.... 8-9

Distance Measurement....8-13

Circumference and Area measurement....8-23

Volume Measurement....8-26

■ Calculations by Application......8-29

Things to Note....8-29

Common Measurement Methods ....8-33

OB Calculations 8-37

Fetal Heart Calculations....8-46

Gynecology Calculations....8-49

Cardiac Calculations....8-52

Abdomen Calculations 8-66

Pediatric Hips Calculations....8-68

Urology Calculations....8-70

Small Parts Calculations....8-71

Musculoskeletal Calculations 8-75

Vascular Calculations 8-76

Chapter 8

Reports 8-85

Viewing Reports 8-85

Report Preview 8-86

Editing Report (Worksheet) 8-89

Adding Comments 8-92

Print Reports 8-94

Saving Reports 8-94

Store SR 8-95

Images 8-95

OB Graph 8-97

Description 8-102

Closing Reports 8-104

Measurement Accuracy

Measurement values can vary depending on the nature of the ultrasound wave, the body's response to ultrasound waves, the measurement tools, algorithms, product settings, probe type, and the actions performed by the user.

Before using this product, make sure to read and understand the following information regarding the causes of measurement errors, and measurement optimization.

Causes of Measurement Errors

Image Resolution

The resolution of an ultrasound image may be limited by spatial causes.

Errors caused by signal range may be minimized by adjusting the focus settings. Optimizing the focus settings increases the resolution of the measurement area. In general, the lateral resolution is lower than the axial resolution. Therefore, measurements should be performed along the axis of the ultrasound beam to obtain accurate values. Gain has a direct impact on the resolution. Gain can be adjusted by using the Gain button for each mode. In general, increasing the frequency of ultrasound enhances resolution.

Pixel Size

This product's ultrasound images consist of pixels. Since a single pixel represents the basic unit of an image, a measurement error may result in the displacement of approximately ±1 pixel when compared to the original image size. However, this error becomes significant only when a narrow area in an image is measured.

Ultrasound Velocity

The average velocity of ultrasound used for measurement is usually 1,540 m/s. The velocity of ultrasound used varies depending on the cell type. The possible range of error is approximately 2-5% depending on the structure of cells (about 2% for typical cells and about 5% for fatty cells).

Doppler Signal Adjustment

During velocity measurement, an error may occur, depending on the cosine angle between the blood flow and the ultrasound beam. For Doppler velocity measurements, the most accurate results can be ensured by aligning the ultrasound beam in parallel with the blood flow. If that is not possible, the angle between them should be adjusted by using the Angle option.

Aliasing

PW Spectral Doppler Mode uses a signal sampling technique to calculate the frequency (or velocity) spectrum. Adjust the baseline or the velocity scale to minimize aliasing. A lower frequency probe can also be used to reduce aliasing.

Calculation Equation

Some of the calculation equations used for clinical purposes originate from hypotheses and approximations. All calculation equations are based on medical reports and articles.

Human Error

Human error may occur due to inappropriate use or lack of experience. This can be minimized through compliance with and thorough understanding of the manuals.

Optimization of Measurement Accuracy

SAMSUNG HS60 - Optimization of Measurement Accuracy - 1

2D Mode

▶ Resolution is in proportion to the frequency of the probe. ▶ Penetration is inversely proportional to the frequency of the probe. The highest resolution can be obtained at the focus of the probe where the ultrasound beam is narrowest. The most accurate measurements can be obtained at the focus depth. As the distance from the focus increases, the beam width increases, which results in lower accuracy. Using the zoom function or minimizing the depth display makes distance or area measurements more accurate.

SAMSUNG HS60 - 2D Mode - 1

M Mode

The accuracy of time measurements can be increased by setting the sweep velocity and the display format to higher values. The accuracy of distance measurements can be increased by setting the display format to a higher value.

SAMSUNG HS60 - M Mode - 1

Doppler Mode

Using lower frequency ultrasound is recommended for measurement of faster blood flows. The size of the sample volume is limited by the axial direction of the ultrasound. ▶ Using lower frequency ultrasound increases penetration. The accuracy of time measurements can be increased when the sweep velocity is increased. The accuracy of velocity measurements can be increased when the vertical scale is set to smaller values. It is most important to use an optimal Doppler angle to enhance the accuracy of velocity measurements.

Color/Power Doppler Mode

A protocol has not been specified for images in Color Doppler Mode or Power Doppler Mode. Therefore, the same limitations imposed on measurements taken in B/W images also apply to the accuracy of measurements taken in Color Doppler and Power Doppler Modes. Using Color/Power Doppler Mode images to measure accurate blood flow velocity is not recommended. The amount of blood flow is calculated based on the average velocity rather than the peak velocity. In all applications, the amount of blood flow is measured in PW Spectral Doppler mode.

Cursor Position

All measurements are affected by input data. Adjust the images on the screen so that they are displayed at maximum granularity. ▶ Use the front edge or boundary point of a probe to make the start and end points of a measurement object more distinct. Make sure that the probe direction remains aligned during measurement.

Measurement Accuracy Table

The following tables show the accuracy of the measurements that can be taken using this product. Ensure that the results of measurement accuracy checks are kept within the ranges specified in the table. Except for certain applications or probes, the following accuracy ranges should be maintained for measurement of distance on a straight line.

SAMSUNG HS60 - Measurement Accuracy Table - 1

NOTE: In case of doubt in the measurements, an accuracy test can be requested via your local Samsung Medison Service Department.

2D ModeSAMSUNG HS60 - Measurement Accuracy Table - 2

MeasurementsAccuracy(Whichever is greater)TestMethodologyAccuracyBased onRange
Axial Distance < ± 4% or 1mm Phantom Acquisition Full Screen
Lateral Distance < ± 4% or 2mm Phantom Acquisition Full Screen
Area < ± 8% or 4 mm 2 Calculation Equation Full Screen
Volume < ± 12% or 8 mm 3 Calculation Equation Full Screen
Angle < ± 4% or 1° Calculation Equation Full Screen

M ModeSAMSUNG HS60 - Measurement Accuracy Table - 3

MeasurementsAccuracy(Whichever is greater)TestMethodologyAccuracyBased onRange
Time< ± 5% or 1 msSignal GeneratorAcquisition0.01 – 11.3 sec
Slope< ± 8% or 4 mm/msCalculation Equation Full Screen

PW/CW Spectral Doppler ModeSAMSUNG HS60 - Measurement Accuracy Table - 4

Doppler MeasurementsAccuracy(Whichever is greater)Test MethodologyAccuracy Based onRange
Velocity < ± 15% Phantom Acquisition 0.1 cm/s – 8.8 m/s
Time < ± 5%Signal Generator Acquisition 10 ms – 9.44 s
Heart Rate < ± 5% or 1 bpm Calculation Equation1 – 43,200 bpm

Basic Measurements

Press the Caliper button on the control panel.

SAMSUNG HS60 - Basic Measurements - 1

NOTE: Take basic measurements of distance and area regardless of the application. For information on measurements for each application, please refer to the 'Measurements by Application' section of this chapter.

The available measurement methods vary depending on the current diagnosis mode. Please refer to the following table:

Measurement Category Diagnosis Modes Measurement Method
Distance measurement2D, M, DDistanceTrace LengthOpen Spline3 Points Angle2 Lines Angle%SStenosis(D)
MDistance(M)SlopeHR(M)Time(M)
DVelocityAccelRIManual TraceLimited TraceHR(D)VolumeFlow(D)VolumeFlow(A)Time(D)Auto TraceS/D RatioD/S Ratio
Circumference and Area measurement2D, M, DEllipseTraceClosed Spline%Stenosis(A)
Volume measurement 2D, M, D1 Dist. Volume2 Dist. Volume3 Dist. VolumeEllipse VolumeEllipse + Dist.VolDisk Volume

[Table 8.1 Basic Measurements by Diagnosis Mode]

Basic Measurement Operations

The following is the information on common button operations for basic measurements:

Selecting/Changing Measurement Method

Select a measurement method using the touch screen. The menu items that can be selected on the touch screen vary according to the diagnosis mode. The selected measurement method is displayed in the User Information area.

Adjusting Font Size

Go to Setup > Measurement > General > Result > Font Size and either enter the font size to be used in the measurement results, or use the 'Font Size' knob button to select a desirable size from 8 to 20.

Canceling Measurement Results

Delete Last: Tap Delete Last on the touch screen to delete the last measurement taken. The value displayed on the corresponding application report will also be deleted.

Specifying the Measurement Result Position

Place the pointer over the measurement and press the Set button. Use the trackball to move the measurement to the desired location, and press the Set button to place the movement at that location.

Resetting Measurement Result Position

Go to Setup > Measurement > General Page, and change the value for Position on 2D Mode or Position On M/D in Result to reset the position of the measurement results as desired.

SAMSUNG HS60 - Resetting Measurement Result Position - 1

NOTE: You may select Left-Top, Left-Bottom, Right-Bottom, Right-Top, or Custom.

Deleting Measurement Results

Clear: Tap Clear on the control panel or the touch screen to delete the measurement.

Printing Measurement Results

Press the established U Key with the Store/Print button on the control panel.

SAMSUNG HS60 - Printing Measurement Results - 1

NOTE: Go to Setup > Customize > Buttons and choose a button to set as Store/Print from the U1 U2 U3 U4 U5 and U6 buttons.

Exiting Basic Measurement

After completing (or canceling) all in-progress measurements, press the Exit button on the control panel.

SAMSUNG HS60 - Exiting Basic Measurement - 1

NOTE: To change measurement units and other settings, select Setup > Measurement > General on the keyboard. For more information, refer to 'Chapter 3. Utilities' in this manual.

2D Distance Trace Trace Length Ellipse Open Spline Closed Spline %Stenosis(D) %Stenosis(A) 2 Lines Angle 3 Points Angle 1 Dist Volume 2 Dist Volume 3 Dist Volume Ellipse Volume Ellipse + Dist Vol Disk Volume Exit Font Size 12

[Figure 8.1 Caliper]

Distance Measurement

SAMSUNG HS60 - Distance Measurement - 1

Distance

This is a basic measurement that is available in all diagnosis modes. Specify two points on a 2D image and measure the length of the straight line between the points.

  1. Select Distance on the monitor or touch screen. Use the trackball and the Set button on the control panel to specify the end points of the measurement.

Use the trackball to place the cursor at the desired position and then press the Set button.

SAMSUNG HS60 - Distance - 1

Repositioning a Point

Instead of pressing the Set button to confirm the point position, you can press the Change button to reset it.

  1. Specify both end points and then the distance between them will be measured.
  2. When the distance has been measured, the result is shown on the screen.

SAMSUNG HS60 - Repositioning a Point - 1

Trace Length

This is a basic measurement that is available in all diagnosis modes. Specify a point on a 2D image and trace a curve from that point to measure its length.

  1. Select Trace Length on the monitor or touch screen. Use the trackball and the Set button on the control panel to specify the start point of the measurement.

Use the trackball to place the cursor at the desired position and then press the Set button.

  1. Use the trackball to draw the desired curve and then press the Set button to set the end point.
  2. Specify both end points and then the length of the curve will be measured.

SAMSUNG HS60 - Trace Length - 1

Editing Curves

Before specifying the end point by pressing the Set button, you can delete part of the curve being traced by rotating the soft menu dial-button 5 counter-clockwise. To restore the deleted curve, rotate the dial-button clockwise.

Open Spline

This is a basic measurement that is available in all diagnosis modes. Specify multiple points on a 2D image to measure the length of the resulting Open Spline curve.

  1. Select Open Spline on the monitor or touch screen. Use the trackball and the Set button on the control panel to specify as many points as desired. After specifying the last point of the Open Spline, press the Set button twice to finish measuring the Open Spline.

At least two points must be specified before the Open Spline can be measured.

  1. The length of the Open Spline curve created with the points you have specified will be calculated and displayed on screen.

3 Points Angle

This is a basic measurement that is available in all diagnosis modes. Place three points on a 2D image and measure the angle formed by the points.

  1. Tap 3 Points Angle on the touch screen.
  2. Specify three points.
  3. The angle formed by the three points will be calculated and displayed on the screen.

2 Lines Angle

This is a basic measurement that is available in all diagnosis modes. Specify two straight lines on a 2D image to measure the angle between the two lines.

  1. Tap 2 Lines Angle on the touch screen.
  2. Draw two straight lines. Refer to 'Distance' for instructions on how to draw a straight line.
  3. The angle between two lines will be calculated and displayed on the screen.

When two angles are calculated, the smaller angle is displayed.

SAMSUNG HS60 - Lines Angle - 1

%Stenosis(D)

StD stands for Stenosis Distance, which is a basic measurement available in all diagnosis modes. The diameter of a blood vessel is measured on a 2D image to calculate its stenosis ratio (%).

  1. Select %Stenosis (D) on the monitor or touch screen.
  2. Measure the total diameter of a blood vessel using the Distance measurement method.
  3. When the second cursor appears, measure the diameter of the vessel's inner wall under stenosis.
  4. Calculate %StD using the following equation:

%Stenosis (D) = (Outer Distance - Inner Distance) / Outer Distance x 100

SAMSUNG HS60 - %Stenosis(D) - 1

Distance(M)

This is a basic measurement that is only available in M mode. Specify two points on an M image, and measure the distance between the two points.

  1. Select Distance (M) on the monitor or touch screen. Specify two points and measure the length of the straight line between the points. This measurement is taken in the same way as 'Distance'.
  2. When the distance has been measured, the result is shown on the screen.

SAMSUNG HS60 - Distance(M) - 1

Slope

This is a basic measurement that is only available in M mode. Specify two points on an M image, and measure the velocity between the two points.

  1. Select Slope on the monitor or touch screen.
  2. Specify two points and measure the length of the straight line between the points. This measurement is taken in the same way as 'Distance'.
  3. When the distance has been measured, the result is shown on the screen.

HR(M)

This is a basic measurement that is only available in M mode. Specify two bars on an image and measure the heart rate between the two bars.

  1. Select HR(M) on the monitor or touch screen.
  2. Use the trackball and the Set button on the control panel to select two bars.
  3. When the measurement has been taken, the result is shown on the screen.

Time(M)

This is a basic measurement that is only available in M mode. Specify two bars on an M image and measure the time between the two bars.

  1. Select Time(M) on the monitor or touch screen.
  2. Use the trackball and the Set button on the control panel to select two bars.
  3. When the measurement has been taken, the result is shown on the screen.

Velocity

This is a basic measurement that is only available in Spectral Doppler mode. Specify one point on a Spectral Doppler image to measure the velocity.

SAMSUNG HS60 - Velocity - 1

NOTE: In a Spectral Doppler image, the X- and Y-axes represent time and velocity, respectively.

  1. Select Velocity on the monitor or touch screen.
  2. Specify a point.
  3. When the measurement has been taken, the result is shown on the screen.

SAMSUNG HS60 - Velocity - 2

Accel

This is a basic measurement that is only available in Spectral Doppler mode. Specify two points on a Spectral Doppler image and measure the velocity at each point to calculate the time and acceleration.

  1. Select Accel on the monitor or touch screen.
  2. Specify two points and measure the length of the straight line between the points. This measurement is taken in the same way as 'Distance'.
  3. When the measurement has been taken, the result is shown on the screen.

The following equation is used for Accel measurement:

Accel = (V _ 2 - V _ 1)(T _ 2 - T _ 1) = dV/dT

SAMSUNG HS60 - Accel - 1

RI

This is a basic measurement that is only available in Spectral Doppler mode. Specify two points on a Spectral Doppler image and measure the velocity at each point to calculate the Resistivity Index (RI).

  1. Tap RI on the touch screen.
  2. Specify two points on a Spectral Doppler image, and measure the velocity at each point.
  3. When the measurement has been taken, the result is shown on the screen.

The equations used for D RI measurement are as follows:

RI = V _ 1 - V _ 2V _ 1

SAMSUNG HS60 - RI - 1

Manual Trace

This is a basic measurement that is only available in Spectral Doppler mode. You can specify a point on a Spectral Doppler image and trace a curve from that point to calculate the blood flow velocity, mean velocity, RI and Pulsatility Index (PI).

  1. Select Manual Trace on the monitor or touch screen.
  2. Trace the curve. When the measurement has been taken, the result is shown on the screen. The measurement results displayed will vary, depending on the settings you have selected in Setup > Measurement > Library > Caliper > D > Manual Trace.

PS: Peak Systolic Velocity

PI: Pulsatility Index

MD: Min Diastolic Velocity

RI: Resistivity Index

ED: End Diastolic Velocity

PS/ED: PS ED Ratio

TAmax: Time Averaged Max Velocity

ED/PS: ED PS Ratio

The equations used for Trace measurement are as follows:

V mean = VTI / Duration of flow, RI = (PS - ED) / PS, PI = (PS - ED) / Vmean

SAMSUNG HS60 - Manual Trace - 1

Limited Trace

This is a basic measurement that is only available in Spectral Doppler mode. Specify two bars on a Spectral Doppler image to calculate the mean velocity between the bars, RI and Pulsatility Index (PI).

  1. Select Limited Trace on the monitor or touch screen. Use the trackball and the Set button on the control panel to select two bars.
  2. When the measurement has been taken, the result is shown on the screen.

PS: Peak Systolic Velocity

PI: Pulsatility Index

MD: Min Diastolic Velocity

RI: Resistivity Index

ED: End Diastolic Velocity

PS/ED: PS ED Ratio

TAmax: Time Averaged Max Velocity

ED/PS: ED PS Ratio

TAMEAN: Time Average Mean Velocity

HR

The equations used for D Limited Trace measurement are as follows:

meanV = VTI / Duration of flow; RI = (PS - ED) / PS; PI = (PS - ED) / Vmean; V1/V2 = V1 / V2

SAMSUNG HS60 - Limited Trace - 1

VolumeFlow(D)

This is a basic measurement that is only available in Spectral Doppler mode and 2D Image Mode. Specify two bars on a Spectral Doppler image, and specify two points in 2D Image mode, to calculate the VolumeFlow.

  1. Select VolumeFlow(D) on the monitor or touch screen.
  2. Use the trackball and the Set button on the control panel to select two bars. This measurement is taken in the same way as 'M Time'. This can only be done in the Loop area.
  3. Use the trackball and the Set button on the control panel to select two points. 2D Image Mode will activate automatically so that you can measure the distance. This measurement is taken in the same way as 'Distance'.
  4. When the measurement has been taken, the result is shown on the screen.

SAMSUNG HS60 - VolumeFlow(D) - 1

Time(D)

This is a basic measurement that is only available in Spectral Doppler mode. Place two bars on a Spectral Doppler image to calculate the time between the bars.

  1. Tap D Time on the touch screen.
  2. Set two bars on the spectrum with the trackball and the Set button.
  3. When the measurement has been taken, the result is shown on the screen.

SAMSUNG HS60 - Time(D) - 1

HR(D)

This is a basic measurement that is only available in Spectral Doppler mode. Place two bars on an image and measure the heart rate between the two bars.

  1. Select HR(D) on the monitor or touch screen.
  2. Use the trackball and the Set button on the control panel to select two bars.
  3. When the measurement has been taken, the result is shown on the screen.

SAMSUNG HS60 - HR(D) - 1

Auto Trace

Spectrum is traced automatically. This can be enabled in the measurement menu in Spectral Doppler mode.

  1. Press Auto Trace in the Measurement menu.
  2. The system traces the spectrum automatically.
  3. When the Trace is complete, the measurement results are displayed on the screen.

SAMSUNG HS60 - Auto Trace - 1

Things to Consider when using Doppler Spectrum Auto Trace

The state of a Doppler Spectrum may affect the measurement results. Please pay attention to the following:

Causes for Trace Failure

  • If the Gain is changed while a Doppler image is in Freeze state, Contour Trace and Peak Trace will not work.
  • If there is little or no noise in an image without a spectrum, Contour Trace will not work.
  • If there is severe noise in an image, Contour Trace will not work.
  • If the Clutter Filter is set too high, AutoTrace and Limited Trace may not work.

Possible Causes of Inaccurate Peak Trace

  • If the PRF (Pulse Repetition Frequency) is lower than the velocity at the site being examined, aliasing may occur. If the original signals are separated from aliasing, a Trace can be carried out, but the peak measurement may not be accurate.
  • If the peak of a spectral waveform is not clear or occurs intermittently, a Trace can be carried out, but the peak measurement may not be accurate.
  • If the Doppler Gain is set too high or too low, it becomes difficult to distinguish spectra. This may result in measurement error.
  • If the Wall Filter is set too high, the spectrum will only be partially displayed. In this case, a Trace can be carried out, but Peak measurement may not be accurate.
  • If abnormal noise or artifacts occur, a Trace can be carried out, but Peak measurement may not be accurate.

Other

– Use of the CW Probe may result in measurement error(s). - Limited Trace is supported only for two-peak spectrums, such as Mitral Valve Inflow and Tricuspid Valve Inflow in the cardiology application.

SAMSUNG HS60 - Other - 1

S/D Ratio, D/S Ratio

This is a basic measurement that is only available in Spectral Doppler mode. After designating two points in a Spectral Doppler image, calculate the velocity ratio by measuring the velocity at each point.

SAMSUNG HS60 - S/D Ratio, D/S Ratio - 1

NOTE: In a Spectral Doppler image, the X- and Y-axes represent time and velocity, respectively.

  1. Tap the S/D button on the touch screen.
  2. After designating two points, measure the velocity at each point. The measurement method is the same as 'RI'.
  3. When the measurement has been taken, the result is shown on the screen.

Circumference and Area measurement

SAMSUNG HS60 - Circumference and Area measurement - 1

Ellipse

This is a basic measurement that is available in all diagnosis modes. Measure the circumference and area of circle (ellipse)-shaped objects on a 2D image.

  1. Click Ellipse on the monitor or tap Ellipse on the touch screen.
  2. Use the trackball and the Set button on the control panel to specify the diameter (axis) of the measurement area.

Use the trackball to place the cursor at the desired position and then press the Set button.

SAMSUNG HS60 - Ellipse - 1

Repositioning Point

Before pressing the Set button to confirm the position, you can press the Change button to reset the position of the point.

  1. Specify the size of the circle (ellipse).

Adjust the size using the trackball and then press the Set button.

  1. When the measurement has been taken, the result is shown on the screen.

The following equation is used for Ellipse measurement:

Circ = π (a + b) · (1 + 3 (a - b/a + b) ^ 21 0 + √ 4 - 3 (a - b/a + b) ^ 2), (a: Half Long axis, b: Half Short axis)

Area = π (x, b: Akis)

Trace

This is a basic measurement that is available in all diagnosis modes. Measure the circumference and area of an irregularly shaped object on a 2D image.

  1. Select Trace on the monitor or touch screen.
  2. Use the trackball and the Set button on the control panel to specify the start point for tracing over the contour of the measurement area. Use the trackball to place the cursor at the desired position and then press the Set button.
  3. Trace the curve so that the measurement cursor returns to the start point, and then press the Set button.

SAMSUNG HS60 - Trace - 1

NOTE: The Trace Line must be a closed curve. If you press the Set button before tracing is complete, a straight line will be traced between the current position and the start point, resulting in a significant error.

  1. When the measurement has been taken, the result is shown on the screen.

The equations used for Trace measurement are as follows:

\triangleright Circ = sum\sqrt{\left{X(n) - X(n - 1)\right}^2 + \left{Y(n) - Y(n - 1)\right}^2} , (N = 1, 2... last point) Area = sum[√X(n-1)×Y(n)-X(n)×Y(n-1)], (N=1,2... last point)

Tips!

Editing Curves

Before specifying the end point by pressing the Set button, you can delete part of the curve being traced by rotating the soft menu dial-button 5 clockwise. To restore the deleted curve, rotate it counter-clockwise.

SAMSUNG HS60 - Editing Curves - 1

Closed Spline

This is a basic measurement that is available in all diagnosis modes. Specify multiple points on a 2D image to measure the circumference and area of the resulting closed spline.

  1. Select Closed Spline on the monitor or touch screen. Use the trackball and the Set button on the control panel to specify as many points as desired. After specifying the last point of the Spline, press the Set button twice to finish measuring the Spline.

At least three points must be specified before spline can be measured.

  1. The circumference and area of the closed spline created with the points you have specified will be calculated and displayed on screen.

SAMSUNG HS60 - Closed Spline - 1

%Stenosis(A)

StA stands for Stenosis Area, which is a basic measurement available in all diagnosis modes. The area of a blood vessel is measured on a 2D image to calculate its stenosis ratio (%).

  1. Select %Stenosis(A) on the monitor or touch screen. Measure the area of the vessel outer wall using the 'Ellipse' measurement method.
  2. When the second cursor appears, measure the area of the stenosed vessel's inner wall. This measurement is taken in the same way as 'Trace'.
  3. Calculate %Stenosis (A) with the following equation:

%Stenosis (A) = (Outer Area - Inner Area) / Outer Area x 100

SAMSUNG HS60 - %Stenosis(A) - 1

VolumeFlow(A)

This is a basic measurement that is only available in Spectral Doppler mode and 2D Image mode. Specify two bars on a Spectral Doppler image and specify an ellipse in 2D Image mode to calculate the VolumeFlow.

  1. Select VolumeFlow(A) on the monitor or touch screen. Use the trackball and the Set button on the control panel to select two bars. This measurement is taken in the same way as 'M Time'. This can only be done in the Loop area.
  2. Use the trackball and the Set button on the control panel to select an ellipse. 2D Image Mode will activate automatically so that you can measure the ellipse. This measurement is taken in the same way as 'Ellipse'.
  3. When the measurement has been taken, the result is shown on the screen.

Volume Measurement

SAMSUNG HS60 - Volume Measurement - 1

NOTE: Since Dual Mode simultaneously displays two images on the screen, you don't have to return to the diagnosis mode to measure volume in Dual Mode.

SAMSUNG HS60 - Volume Measurement - 2

1 Distance Volume

This is a basic measurement that is available in all diagnosis modes. Measure the volume of an object by using only one straight line on a 2D image.

  1. Select 1 Distance Volume on the monitor or touch screen. Specify two points and measure the length of the straight line between the points. This measurement is taken in the same way as 'Distance'.
  2. When the measurement has been taken, the result is shown on the screen. The volume (Vol.) will be calculated along with the length of the line.

The equations used for 1 Distance measurement are as follows:

Vol = 4/3 π · (D/2)3, (D: distance)

SAMSUNG HS60 - Distance Volume - 1

2 Distance Volume

This is a basic measurement that is available in all diagnosis modes. Measure the volume of an object by using two straight lines on a 2D image.

  1. Select 2 Distance Volume on the monitor or touch screen. Specify two points and measure the length of the straight line between the points. This measurement is taken in the same way as 'Distance'.
  2. Measure the length of the last remaining straight line using the same method as above.
  3. When the measurement has been taken, the result is shown on the screen. The volume (Vol.) will be calculated along with the length of each line.

The equations used for 2 Distance measurement are as follows:

D1 gt; D2, π/6 · D12 · D2, (D: distance)

SAMSUNG HS60 - Distance Volume - 1

3 Distance Volume

This is a basic measurement that is available in all diagnosis modes. Measure the volume of an object by using three straight lines on a 2D image.

  1. Select 3 Distance Volume on the monitor or touch screen. Specify two points and measure the length of the straight line between the points. This measurement is taken in the same way as 'Distance'.
  2. Measure the length of the remaining two straight lines using the same method as above.
  3. When the measurement has been taken, the result is shown on the screen. The volume (Vol.) will be calculated along with the length of each line.

The equations used for 3 Distance measurement are as follows:

Vol = 4/3 π · D1/2 · D2/2 · D3/2, (D: distance)

SAMSUNG HS60 - Distance Volume - 1

Ellipse Volume

This is a basic measurement that is available in all diagnosis modes. Measure the volume of a cone-shaped object by using one circle (ellipse) on a 2D image.

  1. Tap Ellipse Volume on the touch screen. Specify the size of the circle (ellipse). This measurement is taken in the same way as 'Ellipse'.
  2. When the measurement has been taken, the result is shown on the screen.

The following equation is used for Ellipse measurement:

Vol. = 4/3 π · Long /2 · Short /2 · Short /2

SAMSUNG HS60 - Ellipse Volume - 1

Ellipse+Dist Vol.

This is a basic measurement that is available in all diagnosis modes. Measure the volume of an object by using one straight line and one circle (ellipse) on a 2D image.

  1. Tap Ellipse+Dist Vol. on the touch screen. Specify the size of the circle (ellipse). This measurement is taken in the same way as 'Ellipse'.
  2. Specify two points and measure the length of the straight line between the points. This measurement is taken in the same way as 'Distance'.
  3. When the measurement has been taken, the result is shown on the screen.

The equation for measuring Ellipse+Dist Vol. is as follows:

Vol = π/6 × a × b × d, (a: Short axis , b: Long axis , d: Distance )

SAMSUNG HS60 - Ellipse+Dist Vol. - 1

Disk Volume

This is a basic measurement that is available in all diagnosis modes. Calculate the volume of an irregularly shaped object by measuring the area and the length of its long axis on a 2D image.

  1. Select Disk Volume on the monitor or touch screen. Draw the contour of the area to be measured. This measurement is taken in the same way as 'Trace'.
  2. Measure the length of the long axis. This measurement is taken in the same way as 'Distance'.
  3. When the measurement has been taken, the result is shown on the screen.

D: The length of a straight line Area: The area of a circle Volume: Volume

Tips!

Editing Curves

Before specifying the end point by pressing the Set button, you can delete part of the curve being traced by rotating the soft menu dial-button 5 counter-clockwise. To restore the deleted curve, rotate it clockwise.

Calculations by Application

Press the Calculator button on the control panel.

Things to Note

Before Starting Measurement

Register Patient

Make sure the currently registered patient information is correct. If the patient is not registered, press the Patient button on the control panel to register the patient. Use the Study Information tab to enter or change a patient's information per diagnosis item. For information on the Patient Information menu and how to enter the information, refer to 'Patient Information' in 'Chapter 6. Starting Diagnosis'.

Check the Probe, Application, and Preset

Check the name of the probe and the application displayed in Title area. To use a different probe or application, press the Probe button on the control panel. In the Probe Selection screen, check the Preset settings.

Measurement Menu Settings

Set the related menus for convenient measurement. For menus related to measurement and their settings, refer to the 'Measurement Settings' in 'Chapter 3. Utilities' of this manual.

Measurement Operations

The following gives information on the common button operations for measurements:

Select Measurement Item

Select from the measurement item menu on the touch screen.

Change Measurement Method

If the current measurement may be taken in more ways than one, the measurement method may be changed. While taking a measurement, you may rotate the dial-button below the Change Tool menu on the touch screen to change the measurement method.

Delete Trace Line

While taking Trace Length or Trace measurements, rotating the touch screen Undo/Redo dial-button clockwise will delete the traced curve. To restore the deleted curve, rotate it counter-clockwise. Move the trackball in the opposite direction to delete the traced line. You can only delete the line while you are manually tracing the Doppler Spectrum.

Deleting Measurement Results

Press the Clear button on the control panel.

SAMSUNG HS60 - Deleting Measurement Results - 1

NOTE: The measurement results are deleted from the screen, but still shown on the report for the corresponding application.

Printing Measurement Results

Press the established button with the Store/Print button on the control panel.

Exiting Measurement

After completing (or canceling) all in-process measurements, press the Exit button on the control panel.

End Diagnosis

Press the End Exam button on the control panel. The study for the currently registered patient will end, and all measurement results will be saved.

Fetus

Either click the Fetus button displayed at the top of the left menu, or rotate the dial-button 1 to select the fetus to measure among A, B, C, and D.

Direction

Either click the Direction button displayed at the top of the left-hand menu or rotate the dial-button 2 to select the direction of the object to measure between left and right. This is only displayed in specific packages.

Location

Either click the Location button displayed at the top of the left-hand menu or rotate the dial-button 3 to select the location of the object to measure from Prox, Mid, and Distal.

Trace Direction

Tap Trace Direction on the touch screen to set the trace direction of the Doppler Spectrum. This is activated only after Limited Trace has been performed in Spectral Doppler mode.

▶ Above: Only the + part of the Doppler waveform is traced. Below: Only the – part of the Doppler waveform is traced. Both: All parts of the Doppler waveform are traced.

Measured Frame

Save the measurement frame. Rotate dial-button 1 to go to the measurement frame.

Threshold

Adjust elimination of weak signals when measuring trace in Spectral Doppler mode.

HR Cycle

Settings may be configured for each application at Setup > Measurement > Applications. In Heart Rate, the number of cycles for heart rate (HR) may be specified at Heart Rate Cycle.

Specifying Measurement Result Position

Place the pointer over the measurement and press the Set button. Use the trackball to move the measurement to the desired location, and press the Set button to place the movement at that location.

Deleting Recent Measurement Item

Tap Delete Latest on the touch screen to cancel the last measurement taken.

Report

Press the Report button on the control panel to switch to the Report screen.

Common Measurement Methods

This section provides information on the common measurement methods used for applications.

SAMSUNG HS60 - Common Measurement Methods - 1

Measurements in Spectral Doppler mode

In general, if you trace a Doppler Spectrum, you obtain results for various measurement items automatically. There are 3 ways to trace a Doppler Spectrum.

Also, HS50/HS60 can select a specific item under the measurement menu and take measurements individually without tracing a Doppler Spectrum.

Auto Trace

Spectrum is traced automatically. This can be enabled in the measurement menu in Spectral Doppler mode.

  1. Press Auto Trace in the measurement menu.
  2. The system traces the spectrum automatically.
  3. When the Trace is complete, the measurement results are displayed on the screen.

Limited Trace

Specify a measurement range, and a spectrum will be traced automatically. This can be enabled in the measurement menu in Spectral Doppler mode.

  1. Select Limited Trace in the measurement menu. A bar will appear, with which you can specify range.
  2. Specify the measurement range. Place the bar at a desired position with the trackball, and press the Set button.
  3. The system traces spectrums within the specified range automatically.
  4. When the Trace is complete, the measurement results are displayed on the screen.

Manual Trace

A spectrum is traced manually. This can be enabled in the measurement menu in Spectral Doppler Mode.

  1. Select Manual Trace in the measurement menu. The measurement cursor will appear over the spectrum.
  2. Trace the spectrum.
  3. When the Trace is complete, the measurement results are displayed on the screen.

Measurement by Item

In the Measurement menu, select an individual item and take a measurement.

  1. Press the Calculator button on the control panel after obtaining a desired image.
  2. Select the item you want from the Measurement menu. The + cursor will appear over the spectral waveform.
  3. Position the "+" cursor and press the Set button.
  4. The measurement results for the selected item are displayed on the screen.
Item Category Unit Formula
PSV (Peak Systolic Velocity) Velocity cm/s
ED (End Diastolic Velocity) Velocity cm/s
MD (Minimum Diastole Velocity) Velocity cm/s
PI (Pulsatility Index) Calculation Ratio (PS-ED)/TAMAX
RI (Resistivity Index) Calculation Ratio(PS-ED)/PS or (PS-MD)/PS
PS/ED (Ratio of PS to ED)Calculation RatioPS/ED
ED/PS (Ratio of ED to PS)Calculation RatioED/PS
TAMAX (Time Average Max Velocity)Velocity cm/s
TAMEAN (Time Average Mean Velocity)Velocity cm/s

SAMSUNG HS60 - Measurement by Item - 1

Taking Measurements via Auto Calc.

You can use Auto Calc to take measurements on predetermined item(s). Measurement items are as follows. For information on setting measurement item(s), please refer to 'Measurement' in 'Chapter 3. Utilities'.

▶ Peak Systolic Velocity (PS) ▶ End Diastolic Velocity (ED) Min Diastole Velocity (MD) ▶ Time Averaged Peak Velocity (TAMAX) ▶ Time Averaged Mean Velocity (TAMEAN) ▶ Resistive Index (RI) Pulsatility Index (PI) Systole/Diastole Ratio (PS/ED) Diastole/Systole Ratio (ED/PS) ▶ Heart Rate (HR) Max Pressure Gradient (PGmax) ▶ Mean Pressure Gradient (PGmean) ▶ Velocity Time Integral (VTI) ▶ Peak A (Peak A)

Volume Flow Measurement

Select Volume Flow in the measurement menu.

Volume Flow can be calculated by measuring an area or distance. For information on measuring distance or area, refer to 'Basic Measurement'. TAMEAN (Time Avg. Mean Velocity) value is measured automatically.

Vesl. Area (Vessel Area)

Measure the area of a blood vessel to calculate TAMEAN and Volume Flow.

VolumeFlow(A) = Area × TAMEAN × 60

Vessel Distance

Measure the width of a blood vessel to calculate TAMEAN and Volume Flow.

VolumeFlow(D) = (π × d²) / 4 × TAMEAN × 60

SAMSUNG HS60 - Vessel Distance - 1

Stenosis Measurement

You can measure the stenosis of each blood vessel system by measuring and calculating an area or distance.

%Stenosis(A)

Measures the area of the inner wall and the outer wall of the blood vessel. %Stenosis(A) stands for Stenosis Area.

  1. Select the %Stenosis(A) menu and the first cursor will appear in 2D Mode.
  2. Measure the area of the vessel's outer wall using the Circ/Area measurement method.
  3. When the second cursor appears, measure the area of the stenosed vessel's inner wall.

%Stenosis (A) = (Outer Area - Inner Area) / Outer Area x 100

%Stenosis(D)

Measure the diameter of the blood vessel. Stenosis(D) stands for Stenosis Distance.

  1. Select the %Stenosis(D) menu and the first cursor will appear in 2D Mode.
  2. Measure the total diameter of a vessel using the Distance measurement method.
  3. When the second cursor appears, measure the diameter of the vessel's inner wall under stenosis.

%Stenosis (D) = (Outer Distance - Inner Distance) / Outer Distance x 100

SAMSUNG HS60 - %Stenosis(D) - 1

Heart Rate Measurement

HR (Heart Rate)

You can calculate heart rates for a certain period of time.

  1. Select HR from the Measurement menu. A bar will appear, with which you can specify range.
  2. Specify the measurement range. Place the bar at a desired position with the trackball, and press the Set button.
  3. The system will automatically measure the heart rate within the measurement range. The measurement result is displayed on screen.

OB Calculations

SAMSUNG HS60 - OB Calculations - 1

NOTE:

Ductus Venosus and Fetal HR can only be measured in Doppler Mode. For information on basic measurement methods, refer to 'Basic Measurements' and 'Common Measurement Methods' in this chapter. For references on measurement items, see 'Reference Manual Part 1'.

Before Taking OB Measurements

OB Basic Information

Enter the information required for OB diagnosis in the Patient Information screen. The basic OB information includes LMP (Last Menstrual Period) and Number of Fetuses.

Once LMP is entered, EDD (Estimated Delivery Date) and GA (Gestational Age) are calculated automatically. LMP is required for the calculation of values such as EDD and SD in obstetrics measurement.

▶ EDD (LMP) = LMP + 280 days ▶ GA (LMP) = Current System Date – LMP LMP = Ovul. Date -14

The physician may choose to override the LMP and manually enter the EDD into 'EDD (LMP)'.

Once the expected delivery date is entered, GA (Gestational Age) is automatically calculated and displayed. EDD (LMP) is renamed to EDD, while GA (LMP) is renamed to GA (EDD).

Once DOC is entered, EDD (Estimated Delivery Date) and GA (Gestational Age) are calculated automatically. EDD (LMP) is renamed to EDD (DOC), while GA (LMP) is renamed to GA (DOC).

Once GA is entered, EDD (Estimated Delivery Date) is entered automatically. EDD (LMP) is renamed to EDD (GA), while GA (LMP) is renamed to GA (Clin).

A maximum of four fetuses can be entered as Number of Fetuses. The default value is '1'. In the case of twins, enter '2'.

For further information about patient information menus and how to input patient information, refer to 'Patient Information' of 'Chapter 6. Starting Diagnosis'.

OB Measurement Menu Settings

Set up the GA Equation, GA Table, and OB measurement menus that are used in obstetrics measurements. The user can manually write, back up or restore GA Tables. For more information on the GA Equation and Table, refer to the Reference Manual Part 1.

SAMSUNG HS60 - OB Measurement Menu Settings - 1

NOTE: For twins, distinguish fetuses by specifying them as Fetus A and Fetus B in the Measurement menu. Either click the Fetus button displayed at the top of the left-hand menu or rotate the dial-button 1 to select the fetus to measure among A, B, C, and D.

For menus related to measurement and their settings, refer to the 'Measurement Settings' in 'Chapter 3. Utilities' of this manual.

1 Trim. Measurement Menu

When the measurements for the selected items are complete, the measurements and gestational age are displayed on the screen. The measurement method for each item is the same as for basic measurement. Measured items are automatically entered into the report.

Measurement Menu Item Mode Method Unit
Fetal BiometryGS All Distance measurement cm
YS All Distance measurement cm
CRL All Distance measurement cm
BPD All Distance measurement cm
FL All Distance measurement cm
ACAllCircumference measurementcm
Fetal CranuimNT All Distance measurement mm
ITAll Distance measurement mm
NBAll Distance measurement cm
Ductus VenosusS Vmax PW Velocity measurement cm/s
D Vmax PW Velocity measurement cm/s
A Vmax PW Velocity measurement cm/s
Auto Trace PW Doppler Spectrum trace
Limited Trace PW Doppler Spectrum trace
Manual Trace PW Doppler Spectrum trace
PS PW Velocity measurement cm/s
ED PW Velocity measurement cm/s
MDPW Velocity measurement cm/s
PIPW Velocity measurement –
RIPW Velocity measurement –
S/DPWContinuous measurement –
Fetal HRPWHeart Ratebpm

SAMSUNG HS60 - Trim. Measurement Menu - 1

Automatic Calculation

Some items in the measurement menu are automatically calculated based on measurements of other items.

SAMSUNG HS60 - Automatic Calculation - 1

NOTE: For reference, the Osaka University/Tokyo University methods are mainly used in Asia, the Merz method in Europe, and the Shepard/Hadlock methods on the American continent.

SAMSUNG HS60 - Automatic Calculation - 2

2-3 Trim. Measurement Menu

When the measurements for the selected items are complete, the measurements and gestational age are displayed on the screen. The measurement method for each item is the same as for basic measurement. Measured items are automatically entered into the report.

Measurement Menu Item Mode Method Unit
Fetal BiometryGS All Distance measurement cm
CRL All Distance measurement cm
YS All Distance measurement cm
BPD, OFD All Continuous measurement
BPD All Distance measurement cm
OFD All Distance measurement cm
HCAllCircumference measurementcm
APAD, TADAll Continuous measurement
APADAll Distance measurement cm
TADAllDistance measurementcm
ACAllCircumference measurementcm
FTAAllArea measurement cm2
FL All Distance measurement cm
SL All Distance measurement cm
APTD, TTDAll Continuous measurement
APTDAllDistance measurementcm
TTD All Distance measurement cm
ThCAllCircumference measurementcm
EFW All- -
Fetal Long BonesHL All Distance measurement cm
ULNA All Distance measurement cm
TIB All Distance measurement cm
RAD All Distance measurement cm
FIB All Distance measurement cm
CLAV All Distance measurement cm
LV All Distance measurement cm
Fetal CraniumNT All Distance measurement mm
IT All Distance measurement mm
NBAll Distance measurement cm
NF All Distance measurement cm
CEREBAll Distance measurement cm
CMAll Distance measurement cm
Lat VentAll Distance measurement cm
OODAll Distance measurement cm
IODAll Distance measurement cm
HWAll Distance measurement cm
FMF angleAllAngle calculationdegree
Lt. Fetal Others Rt. Fetal OthersFootAll Distance measurement cm
Ear All Distance measurement cm
MPAll Distance measurement cm
Renal LAll Distance measurement cm
Renal APAll Distance measurement cm
Pelvis All Distance measurement cm
AFIQ1All Distance measurement cm
Q2All Distance measurement cm
Q3All Distance measurement cm
Q4All Distance measurement cm
MVPAll Distance measurement cm
CTARThD ap All Distance measurement cm
ThD trans All Distance measurement cm
HrtD ap All Distance measurement cm
HrtD trans All Distance measurement cm
ThA All Area measurement cm2
HrtAAll Area measurement cm2
Maternal OthersCervix L All Distance measurement cm
Placenta ThickAllDistance measurementcm
PLIS Vmax PWVelocity measurement cm/s
D Vmax PWVelocity measurement cm/s
A Vmax PW Velocity measurement cm/s
Umbilical A Lt. Mid Cereb A Rt. Mid Cereb A Lt. Uterine A Rt. Uterine A Placenta A Lt. Fetal Carotids Rt. Fetal Carotids Fetal Aorta Lt. Renal A Rt. Renal A%StDAllCalculation after distance measurement%
%StAAllCalculation after area measurement%
Auto TracePWDoppler spectrum trace
Limited TracePWDoppler spectrum trace
Manual TracePWDoppler spectrum trace
PSPWVelocity measurementcm/s
EDPWVelocity measurementcm/s
MDPWVelocity measurementcm/s
PIPWVelocity measurement-
RIPWVelocity measurement-
S/DPWContinuous measurement
VF(D)PWCalculate after measuring TAmean, Vesl., and Dist.ml/min
VF(A)PWCalculate after measuring TAmean, Vesl., and Areaml/min
Fetal HRFetal HRM, PWHeart Ratebpm
Ductus VenosusS Vmax PW Velocity measurement cm/s
D Vmax PW Velocity measurement cm/s
A Vmax PW Velocity measurement cm/s
Auto Trace PW Doppler spectrum trace
Limited Trace PW Doppler spectrum trace
Manual Trace PW Doppler spectrum trace
PS PW Velocity measurement cm/s
ED PW Velocity measurement cm/s
MDPW Velocity measurement cm/s
PIPW Velocity measurement –
RIPW Velocity measurement –
S/DPWContinuous measurement –

SAMSUNG HS60 - 2-3 Trim. Measurement Menu - 1

AFI (Amniotic Fluid Index)

Measure the amniotic fluid index. Measurements are performed by dividing the pregnant woman's abdomen into four parts. The distance between the fetus and the farthest point of each area is measured. To obtain a specific image from each quadrant plane, press the Freeze button to go to the diagnosis mode. After obtaining the image, press the Freeze button again to return to the measurement mode.

SAMSUNG HS60 - AFI (Amniotic Fluid Index) - 1

Calculating Estimated Fetal Weight (EFW)

When measurements for the following items are complete, the system uses the results to calculate the estimated fetal weight automatically. For an equation for calculating fetal weight, please refer to 'Estimated Fetal Weight Formula' in the Reference Manual Part 1.

BPD and AC

BPD, FL, and FTA

BPD, APTD, TTD, and FL

BPD, APTD, TTD, and SL

BPD and TTD

AC and FL

BPD, AC, and FL

HC, AC, and FL

BPD, HC, AC, and FL

AC

Continuous Measurement/Review for EFW Calculation

You can measure a series of OB items to calculate the EFW.

Tips!

Before starting measurement

  1. Make sure that the User Key has been set for EFW continuous measurements. You can configure the User Key for EFW continuous measurements at Setup > Customize > Buttons > User Key > EFW Measure. For more information, refer to 'Peripheral Device Settings' in 'Chapter 3. Utilities'.
  2. Check EFW Reference. If it is not set, or if you want to change it, select it at Setup > Measurement > Author > Estimated Fetal Weight.

SAMSUNG HS60 - Before starting measurement - 1

NOTE: This function is not available in 3D mode.

Measurement method

  1. Press User Key 1 (or User Key 2, 3, 4, 5, 6) on the control panel. The OB Measurement menu will be displayed on screen.
  2. Measure the items for EFW calculation by using the trackball and the Set button.
  3. Use the trackball and the Set button on the control panel again to start the measurement of the following items.
  4. Once all measurements have been taken, the EFW is displayed on screen.

The EFW measurements taken and the order in which they are measured are as follows:

Reference Measure Item (by Order)
Campbell AC
HadlockAC→BPD
Hadlock1AC→FL
Hadlock2BPD→AC→FL
Hadlock3HC→AC→FL
Hadlock4BPD, HC→AC→FL
HansmannBPD→TTD
MerzBPD→AC
OsakaBPD→FL→FTA
PerssonBPD→FL→APAD→TAD
SchildHC→AC→FL
ShepardAC→BPD
Shinozuka1BPD→FL→AC
Shinozuka2BP→APTD, TTD→SL
Shinozuka3BPD→APTD, TTD→FL
TokyoBPD→APTD, TTD→FL

Review the Result of EFW Calculation

  1. Press User Key 1 (or User Key 2, 3, 4, 5, 6) on the control panel. The measured items taken for calculating EFW will be displayed on screen together with the result.
  2. To remove the results from the screen, press the Clear button on the control panel.

Fetal Heart Calculations

The measurement method for each item is the same as for basic measurement. In addition, measurement items are similar to those of cardiology measurements (Cardiac Calculations). Measured items are automatically entered into the report.

SAMSUNG HS60 - Fetal Heart Calculations - 1

NOTE:

For information on basic measurement methods, refer to 'Basic Measurements' and 'Common Measurement Methods' in this chapter. For references on measurement items, see 'Reference Manual Part 1'.

Measurement Menu Item Mode Method Unit
LV Vol. (Simpson)LVEDV A2C All Dist20 ml
LVESV A2C All Dist20 ml
LVEDV A4C All Dist20 ml
LVESV A4C All Dist20 ml
2D EchoAsc Ao All Distance measurement cm
MPA DiamAll Distance measurement cm
Duct Art All Distance measurement cm
LA Diam All Distance measurement cm
RA DiamAll Distance measurement cm
RVDdAll Distance measurement cm
IVSAll Distance measurement cm
LVIDd All Distance measurement cm
LVIDsAll Distance measurement cm
LVPWAll Distance measurement cm
HrtCAllCircumference measurementcm
ThCAllCircumference measurementcm
CTARThD ap All Distance measurement cm
ThD trans All Distance measurement cm
HrtD ap All Distance measurement cm
HrtD trans All Distance measurement cm
ThAAllArea measurement cm2
HrtAAllArea measurement cm2
Fetal HRFetal HRM, PWHeart Ratebpm
M EchoIVSdMDistance measurement cm
LVIDdMDistance measurement cm
LVIDsMDistance measurement cm
LVPWdMDistance measurementcm
IVSsMDistance measurement cm
LVPWs MDistance measurement cm
RVDdMDistance measurement cm
MPA Duct Arteriosus IVC Asc Aorta Dsc AortaAuto TracePWDoppler spectrum trace
Limited TracePWDoppler spectrum trace
Manual TracePWDoppler spectrum trace
PSPW Velocity measurement cm/s
EDPW Velocity measurement cm/s
MD PW Velocity measurement cm/s
PIPW Velocity measurement -
RIPW Velocity measurement -
S/D PWContinuous measurement
Duct VenosusSVmax PWVelocity measurement cm/s
DVmax PWVelocity measurement cm/s
AVmax PW Velocity measurement cm/s
MV TVE PW Velocity measurement cm/s
A PW Velocity measurement cm/s
Vmax PW Velocity measurement cm/s
PLIS Vmax PW Velocity measurement cm/s
D Vmax PW Velocity measurement cm/s
A Vmax PW Velocity measurement cm/s
TEITST PW Time measurement ms
ET PW Time measurement ms

CTAR (Cardio-Thorax Area Ratio)

This measurement compares the size of the fetus' heart in relation to the size of its thorax. ThD ap, ThD trans, HrtD ap, and HrtD trans values are acquired to obtain the comparative value.

CTAR = HrtDap × HrtDtrans/ThDap × ThDtrans × 1 0 0

Gynecology Calculations

SAMSUNG HS60 - Gynecology Calculations - 1

NOTE:

For information on basic measurement methods, refer to 'Basic Measurements' and 'Common Measurement Methods' in this chapter. For references on measurement items, refer to the Reference Manual Part 2.

SAMSUNG HS60 - NOTE: - 1

Before Taking GYN Measurements

Enter the information required for GYN diagnosis in the Patient Information screen. Basic information for gynecology includes Gravida, Para, Aborta, and Ectopic.

SAMSUNG HS60 - Before Taking GYN Measurements - 1

Measurement Menu

The measurement method for each item is the same as for basic measurement. Measured items are automatically entered into the report.

Measurement Menu Item Mode Method Unit
UterusLength All Distance measurement cm
Width All Distance measurement cm
Height All Distance measurement cm
Endo.Thick All Distance measurement cm
CervixLt. CystRt. CystLt. OvaryRt. OvaryLength All Distance measurement cm
Width All Distance measurement cm
Height All Distance measurement cm
Measurement Menu Item Mode Method Unit
Lt. Follicle Rt. FollicleFollicle #1 All Volume measurement ml
Follicle #2 All Volume measurement ml
Follicle #3 All Volume measurement ml
Follicle #4 All Volume measurement ml
Follicle #5 All Volume measurement ml
Follicle #6 All Volume measurement ml
Follicle #7 All Volume measurement ml
Follicle #8 All Volume measurement ml
Follicle #9 All Volume measurement ml
Follicle #10 All Volume measurement ml
Follicle #11 All Volume measurement ml
Follicle #12 All Volume measurement ml
Lt. Ovarian A Rt. Ovarian A Lt. Uterine A Rt. Uterine A Pericystic Endometrial%StD AllCalculation after distance measurement%
%StA AllCalculation after area measurement%
Auto Trace PW Doppler spectrum trace
Limited Trace PW Doppler spectrum trace
Manual Trace PW Doppler spectrum trace
PS PW Velocity measurement cm/s
EDPW Velocity measurement cm/s
MDPW Velocity measurement cm/s
PIPW Velocity measurement -
RIPW Velocity measurement -
Vol.Flow(D)PWCalculate after measuring TAmean, Vesl., and Dist.ml/min
Vol.Flow(A)PWCalculate after measuring TAmean, Vesl., and Areaml/min
S/DPWContinuous measurement-
Measurement Menu Item Mode Method Unit
Mass1Mass2Mass3Endo. PolypLt. Ovarian MassRt. Ovarian MassUterine Fibroid1Uterine Fibroid2Uterine Fibroid3Cervical FibroidEctopicLength All Distance measurement cm
Width All Distance measurement cm
Height All Distance measurement cm
Auto Trace PW Doppler spectrum trace
Limited Trace PW Doppler spectrum trace
Manual Trace PW Doppler spectrum trace
PSPW Velocity measurementcm/s
EDPW Velocity measurementcm/s
MDPW Velocity measurementcm/s
PIPW Velocity measurement-
RIPW Velocity measurement-
S/DPWContinuous measurement-

Most of the gynecology measurements are distance measurements and volume measurements based on the distance measurement results. If multiple images, such as long axis images and transverse axis images are needed, press the Freeze button to switch to Scan Mode and obtain images from another perspective.

Cardiac Calculations

SAMSUNG HS60 - Cardiac Calculations - 1

NOTE: Cardiac measurement is an optional item.

The measurement method for each item is the same as for basic measurement. Measured items are automatically entered into the report.

SAMSUNG HS60 - Cardiac Calculations - 2

NOTE:

For information on basic measurement methods, refer to 'Basic Measurements' and 'Common Measurement Methods' in this chapter. For references on measurement items, refer to the Reference Manual Part 2.

Measurement Menu Item Mode Method Unit
LV (2D)All LV (2D) All Continuous measurement
All LVd (2D) All Continuous measurement
IVSd All Distance measurement cm
LVIDd All Distance measurement cm
LVPWdAll Distance measurement cm
All LVs (2D)All Continuous measurement
IVSsAll Distance measurement cm
LVIDsAll Distance measurement cm
LVPWsAll Distance measurement cm
LV(2D)HRAllHeart Ratebpm
RV (2D)RVAWdAllDistance measurementcm
RVIDdAll Distance measurement cm
RVAdAllArea measurement cm2
RVAWsAllDistance measurementcm
RVIDsAll Distance measurement cm
RVAsAllArea measurement cm2
RV MajorAll Distance measurement cm
RV MinorAll Distance measurement cm
LV (M)All LV/RV (M) M Continuous measurement
All LV (M) M Continuous measurement
LV EF(M) M Continuous measurement
IVSd M Distance measurement cm
LVIDd M Distance measurement cm
LVPWd M Distance measurement cm
IVSsM Distance measurement cm
LVIDsM Distance measurement cm
LVPWsM Distance measurement cm
LVETMTime measurementms
LVPEPM Time measurement ms
LV(M) HR MHeart Rate bpm
Time Septal to PWM Time measurement ms
MAPSEM Distance measurement cm
RV (M)All RV (M) M Continuous measurement
RVAWd M Distance measurement cm
RVIDdM Distance measurement cm
RVAWsM Distance measurement cm
RVIDsM Distance measurement cm
RVPEPMTime measurementms
RVETM Time measurement ms
TAPSEM Distance measurement cm
LV Vol. (Simpson)LVEDV A2CAllDist 20ml
LVESV A2CAllDist 20ml
LVEDV A4CAllDist 20ml
LVESV A4CAllDist 20ml
BP HRAllHeart Ratebpm
LV Vol. (A/L)LVEDV A2C AL All Dist 20 ml
LVESV A2C AL All Dist 20 ml
HR A2C All Heart Rate bpm
LVEDV A4C AL All Dist 20 ml
LVESV A4C AL All Dist 20 ml
HR A4C All Heart Rate bpm
LV Vol. (Bullet)LVAd SAX MV All Area measurement cm 2
LVAs SAX MV All Area measurement cm 2
LVLd ApicalAllDistance measurementcm
LVLs ApicalAllDistance measurementcm
HR BulletAll Heart Rate bpm
LV MassAll LV MassAllContinuous measurement-
LVAd SAX PM EpiAll Area measurement cm 2
LVAd SAX PM All Area measurement cm 2
LVLd apicalAllDistance measurementcm
LV TE aAllDistance measurementcm
LV TE dAllDistance measurementcm
AortaAo Diam (2D)AllDistance measurementcm
Ao Diam(M)MDistance measurementcm
Asc Ao DiamAllDistance measurementcm
Desc Ao DiamAllDistance measurementcm
Ao Arch DiamAllDistance measurementcm
Ao Isth DiamAllDistance measurementcm
Ao ST Junct DiamAllDistance measurementcm
Ao Sinus DiamAllDistance measurementcm
LAAll LA Vol. All Continuous measurement
LA/Ao (2D) All Distance measurement cm
LA Diam (2D) All Distance measurement cm
LA/Ao(M) M Distance measurement cm
LA/Diam(M) M Distance measurement cm
LA Major All Distance measurement cm
LA Minor All Distance measurement cm
LAAd A2C AllArea measurementcm 2
LAAs A2C AllArea measurementcm 2
LAAd A4C AllArea measurementcm 2
LAAs A4C AllArea measurementcm 2
LA Vol. (Simpson)LAEDV A2C AllDist 20ml
LAESV A2C AllDist 20ml
LAEDV A4C AllDist 20ml
LAESV A4C AllDist 20ml
RARA Diam (2D)All Distance measurement cm
RA Major All Distance measurement cm
RA MinorAll Distance measurement cm
RAAdAllArea measurement cm2
RAAsAllArea measurement cm2
RAEDVAllDist 20ml
RAESVAllDist 20ml
LVOTAuto Trace PW Doppler Spectrum trace
Limited Trace PW Doppler Spectrum trace
Manual Trace PW Doppler Spectrum trace
LVOT Diam All Distance measurement cm
LVOT Vmax PW Velocity measurement cm/s
LVOT VTI PW Doppler Spectrum trace cm
LOVT HR PWHeart Rate bpm
RA Vol. (Simpson)RAEDV A2CAllDist 20ml
RAESV A2C AllDist 20 ml
RAEDV A4CAllDist 20ml
RAESV A4C AllDist 20 ml
RVOTAuto Trace PW Doppler Spectrum trace
Limited Trace PW Doppler Spectrum trace
Manual Trace PW Doppler Spectrum trace
RVOT Diam All Distance measurement cm
RVOT VmaxPW Velocity measurement cm/s
RVOT VTIPW Doppler Spectrum trace cm
RVOT HRPWHeart Ratebpm
AVAV Auto Trace PWDoppler Spectrum trace
AV Limited Trace PWDoppler Spectrum trace
AV Manual Trace PWDoppler Spectrum trace
AV Cusp All Distance measurement cm
AV Cusp(M) M Distance measurement cm
AV Diam All Distance measurement cm
AVA PlanimetryAllArea measurement cm2
Q to AV OpenMTime measurementms
R-R IntM, PWHeart Ratebpm
AV Vmax PWVelocity measurement cm/s
AV PHT PWTime measurement ms
AV VTIPWDoppler Spectrum tracecm
AV AccT PWTime measurement ms
AV ETPWTime measurementms
AV AccT/ETPWContinuous measurement
AV DecTPWTime measurementms
Desc. Ao Vel.PWVelocity measurementcm/s
AR Auto Trace PWDoppler Spectrum trace
AR Limited Trace PWDoppler Spectrum trace
AVAR Manual Trace PWDoppler Spectrum trace
AR VCW All Distance measurement cm
AR Vmax PW Velocity measurement cm/s
AR ed Vmax PW Velocity measurement cm/s
AR PHT PW Time measurement ms
AR VTI PW Doppler Spectrum trace cm
AR AccT PW Time measurement ms
AR DecTPW Time measurement ms
AR PISA Rad CPISA-Radius cm
AVOPW Time measurement ms
AVCPW Time measurement ms
AR Jet DiamAll Distance measurement cm
AR Jet AreaAllArea measurement cm2
MVAll MV(M)MContinuous measurement -
MV D-E ExcursionM Distance measurement cm
MV E-F SlopeMVelocity measurement cm/s
MV A-C IntervalMTime measurement ms
MV EPSS M Distance measurement cm
MV VpMVelocity measurement cm/s
MV Ann DiamAll Distance measurement cm
MV Diam1All Distance measurement cm
MV Diam2All Distance measurement cm
MVA PlanimetryAllArea measurement cm2
MV Auto TracePWDoppler Spectrum trace
MV Limited TracePW Doppler Spectrum trace
MV Manual TracePW Doppler Spectrum trace
MVMV E-DT-A PW Continuous measurement
MV E/A PW Continuous measurement -
MV Peak E PW Velocity measurement cm/s
MV Peak A PW Velocity measurement cm/s
MV VTI PW Distance measurement cm
MV VmaxPW Velocity measurement cm/s
MV PHTPW Time measurementms
MV AccTPW Time measurementms
MV DecT PWTime measurement ms
MV A Dur PWTime measurement ms
MV ETPW Time measurementms
R-R Int M, PWHeart Rate bpm
MR Auto TracePW Doppler Spectrum trace
MR Limited TracePW Doppler Spectrum trace
MR Manual TracePW Doppler Spectrum trace
MR VCW All Distance measurement cm
MR VmaxPW Velocity measurement cm/s
MR VTI PW Doppler Spectrum trace cm
MR dp/dt PW Continuous measurement mmHg/s
MV IVRT PWTime measurement ms
MR PISA Rad CPISA-Radius cm
MV HRPW Heart Ratebpm
E/E'PW Continuous measurement
Measurement Menu Item Mode Method Unit
TVTV D-E Excursion M Distance measurement cm
TV E-F Slope M Velocity measurement cm/s
TV A-C Interval M Time measurement ms
TV Auto Trace PWDoppler Spectrum trace
TV Limited TracePWDoppler Spectrum trace
TV Manual TracePWDoppler Spectrum trace
TV Ann DiamAllDistance measurementcm, mm
TV Diam1AllDistance measurement cm
TV Diam2AllDistance measurement cm
TVA PlanimetryAllArea measurementcm
Q to TV OpenM Time measurement ms
TV VmaxPWVelocity measurement cm/s
TV VTIPWDoppler Spectrum tracecm
TV E/APWContinuous measurement -
TV Peak EPWVelocity measurement cm/s
TV Peak APWVelocity measurement cm/s
TV PHT PWTime measurement ms
TV AccTPWTime measurement ms
TV DecT PWTime measurement ms
TV A DurPWTime measurement ms
R-R IntM, PWHeart Ratebpm
TR Auto Trace PWDoppler Spectrum trace
TR Limited TracePWDoppler Spectrum trace
TR Manual TracePWDoppler Spectrum trace
TR VCWAllDistance measurementcm
TR VmaxPWVelocity measurement cm/s
TVTR VTI PW Doppler Spectrum trace cm
TR dp/dtPWCalculation after time measurement mmHg/s
TR PISA Rad C PISA-A Radius cm
RAP M, PW RAPmmHg
TV HRPWHeart Ratebpm
PVPV Auto TracePW Doppler Spectrum trace
PV Limited TracePW Doppler Spectrum trace
PV Manual TracePW Doppler Spectrum trace
PV Ann DiamAllDistance measurementcm
PVA PlanimetryAllArea measurement cm2
PV VmaxPWVelocity measurementcm/s, m/s
PV PHTPWVelocity measurementcm/s
PV VTI PW Doppler Spectrum trace cm
PV AccT/ETPWContinuous measurement
PV AccT PWTime measurement ms
PV ETPWTime measurementms
PV DecTPWTime measurementms
R-R IntM, PWHeart Ratebpm
Q to PV OpenMTime measurementms
Q to PV CloseMTime measurementms
PR Auto TracePW Doppler Spectrum trace
PR Limited TracePW Doppler Spectrum trace
PR Manual TracePW Doppler Spectrum trace
MPA VmaxPWVelocity measurementcm/s
PR VCW AllDistance measurement cm
PR VmaxPWVelocity measurementcm/s
PVPR PHT PW Time measurement ms
PR VTI PW Doppler Spectrum trace cm
PR AccT PW Time measurement ms
PR DecT PW Time measurement ms
PR End Vel. PW Velocity measurement cm/s
PR PISA Rad CPISA-Radius cm
Tei IndexAll LV Tei IndexPWContinuous measurement
LV TST PW Time measurement ms
MV ET PW Time measurement ms
LV IVCTPW Time measurement ms
LV IVRT PW Time measurement ms
All RV Tei IndexPWContinuous measurement
RV TSTPW Time measurement ms
RV ET PW Time measurement ms
RV IVCT PW Time measurement ms
RV IVRTPW Time measurement ms
Pulm. VeinsP Vein S/D PWContinuous measurement
P Vein S VmaxPW Velocity measurement cm/s
P Vein D VmaxPW Velocity measurement cm/s
P Vein A VmaxPW Velocity measurement cm/s
P Vein A DurPW Time measurement ms
Hepatic VeinsH Vein S/D PWContinuous measurement
H Vein S VmaxPW Velocity measurement cm/s
H Vein D VmaxPW Velocity measurement cm/s
H Vein A VmaxPW Velocity measurement cm/s
H Vein A DurPW Time measurement ms
Tissue DopplerLV E'-A'-S' PW Continuous measurement
LV Peak E' PW Velocity measurement cm/s
LV Peak A' PW Velocity measurement cm/s
LV Peak S' PW Velocity measurement cm/s
LV AccT PW Time measurement ms
LV DecT PW Time measurement ms
RV E'-A'-S'PW Continuous measurement
RV Peak E'PW Velocity measurement cm/s
RV Peak A'PW Velocity measurement cm/s
RV Peak S'PW Velocity measurement cm/s
RV AccTPW Time measurement ms
RV DecT PWTime measurement ms
LV Lat E'-A'-S'PW Continuous measurement
LV Lat Peak E'PW Velocity measurement cm/s
LV Lat Peak A'PW Velocity measurement cm/s
LV Lat Peak S'PW Velocity measurement cm/s
LV Lat AccTPWTime measurement ms
LV Lat DecTPWTime measurement ms
Qp/QsSystemic VTI PWDoppler Spectrum trace cm
Systemic HR PWHeart Rate bpm
Pulmonic VTIPWDoppler Spectrum trace cm
Pulmonic HRPWHeart Ratebpm
ShuntsMPA Diam All Distance measurement cm
LPA Diam All Distance measurement cm
RPA Diam All Distance measurement cm
SVC Diam, Exp All Distance measurement cm
SVC Diam, Insp All Distance measurement cm
SVC S/D PW Continuous measurement
SVC S Vmax PW Velocity measurement cm/s
SVC D VmaxPW Velocity measurement cm/s
SVC A VmaxPW Velocity measurement cm/s
SVC A Dur PWTime measurement ms
IVC S/DPW Continuous measurement
IVC S VmaxPW Velocity measurement cm/s
IVC D VmaxPW Velocity measurement cm/s
IVC A VmaxPW Velocity measurement cm/s
IVC A Dur PWTime measurement ms
PEdAll Distance measurement cm
PEsAll Distance measurement cm
IVCIVC Diam, ExpAll Distance measurement cm
IVC Diam, Insp All Distance measurement cm
IVC Diam, Exp(M)M Distance measurement cm
IVC Diam, Insp(M)M Distance measurement cm

Dist 20

Trace the circumference of the heart and then draw the axis of the heart. The system automatically draws 20 lines perpendicular to the axis to calculate the volume.

SAMSUNG HS60 - Dist 20 - 1

NOTE:

▶ MR dp/dt can be measured only at 1-3 m/s. In Dual 2D Mode, two images can be viewed simultaneously. For RVAWd, RVIDd, RVAWs, and RVIDs, see the LV measurement method. MPA Diam, RPA Diam, and LPA Diam are measured under Aortic Valve Level in Parasternal Short Axis. ▶ C Mode is mainly used for measuring reverse cardiac blood flow. Since velocity data is required for measuring PISA-Radius or PISA-Alias Vel., set color display to Velocity or Vel + Var in C mode. For relevant settings, please refer to 'Color Doppler Mode' in 'Chapter 7. Diagnosis Mode'. ▶ Tissue Doppler can be measured in TDI Mode.

Abdomen Calculations

The measurement method for each item is the same as for basic measurement. Measured items are automatically entered into the report.

SAMSUNG HS60 - Abdomen Calculations - 1

NOTE:

It is convenient to calculate each measurement value on the Spectral Doppler image. For information on basic measurement methods, refer to 'Basic Measurements' and 'Common Measurement Methods' in this chapter.

Abdomen Measurement MenuSAMSUNG HS60 - NOTE: - 1

Measurement Menu Item Mode Method Unit
GallbladderCBD All Distance measurement cm
GB Wall All Distance measurement cm
Length All Distance measurement cm
Width All Distance measurement cm
Height All Distance measurement cm
PancreasHead All Distance measurement cm
BodyAll Distance measurement cm
TailAll Distance measurement cm
DuctAll Distance measurement cm
BowelStomach WallAllDistance measurementcm
Small Bowel WallAllDistance measurementcm
Large Bowel WallAllDistance measurementcm
Lt. Kidney Vol.Rt. Kidney Vol.LiverSpleenLength All Distance measurement cm
Height All Distance measurement cm
Width All Distance measurement cm
AortaLt.RARt.RALt.Seg.ARt.Seg ALt.Arc.ARt.Arc ACeliac ASplenic AC Hepatic AR Hepatic AL Hepatic ASMAIMA%StD AllCalculation after distance measurement%
%StA AllCalculation after area measurement%
Auto Trace PW Doppler Spectrum trace
Limited Trace PW Doppler Spectrum trace
Manual Trace PW Doppler Spectrum trace
PS PW Velocity measurement cm/s
EDPW Velocity measurement cm/s
MDPW Velocity measurement cm/s
PIPW Velocity measurement -
RIPW Velocity measurement -
S/D PWContinuous measurement
Vol.Folw(D)PWCalculate after measuring TAmean, Vesl., and Dist.ml/min
Vol.Flow(A)PWCalculate after measuring TAmean, Vesl., and Areaml/min
IVCRenal VR Potal VM Potal VL Potal VR Hepatic VM Hepatic VL Hepatic VSMVIMVSplenic VVMaxPW Velocity measurement cm/s
Dur T PWTime measurement ms
Vesl.Dist.PWDistance measurementcm
Vesl.AreaPWArea measurement cm2

Pediatric Hips Calculations

SAMSUNG HS60 - Pediatric Hips Calculations - 1

Measurement Menu

The measurement method for each item is the same as for basic measurement. Measured items are automatically entered into the report.

SAMSUNG HS60 - Measurement Menu - 1

NOTE: For information on basic measurement methods, refer to 'Basic Measurements' and 'Common Measurement Methods' in this chapter.

Measurement Menu Item Mode Method Unit
Hip Angle Type ALLCalculation of angle after measurement of three straight linesdegree

SAMSUNG HS60 - Measurement Menu - 2

Measurement Methods

  1. Specify the first straight line by using the trackball and the Set button.

Use the trackball to place the cursor at the desired position and then press the Set button.

SAMSUNG HS60 - Measurement Methods - 1

Repositioning a Point

Before pressing the Set button to confirm the position, you can press the Change button to reset the position of the point.

  1. Repeat the above process to specify two other straight lines.
  2. The angle between them will be calculated automatically.

α: The angle between the first and the second straight lines β: The angle between the first and the third straight lines

  1. When the measurement has been taken, the result is shown on the screen.

See the table below for Hip Joint Type information:

Type α β
1a 60 ≤ α < 90 0 < β < 55
1b 60 ≤ α < 90 55 ≤ β < 90
2a/b 50 ≤ α < 60 0 < β < 90
2c 43 ≤ α < 50 77 ≤ β < 90
d 43 ≤ α < 50 0 < β < 77
3/4 0 < α < 43

[Table 8.2 Hip Joint Type Table]

Urology Calculations

SAMSUNG HS60 - Urology Calculations - 1

Before Taking Urology Measurements

Set the related menus for convenient measurement.

Refer to the 'Setting Measurements' section in 'Chapter 3. Utilities' for additional information.

SAMSUNG HS60 - Before Taking Urology Measurements - 1

Measurement Menu

The measurement method for each item is the same as for basic measurement. Measured items are automatically entered into the report.

SAMSUNG HS60 - Measurement Menu - 1

NOTE:

For information on basic measurement methods, refer to 'Basic Measurements' and 'Common Measurement Methods' in this chapter. For references on measurement items, refer to the Reference Manual Part 2.

3Distance

Calculate a volume by measuring three distances.

Measurement Menu Item Mode Method Unit
WG ProstateT-ZoneBladderPre ResidualPost ResidualLength All Distance measurement cm
Height All Distance measurement cm
Width All Distance measurement cm
Lt. RenalRt. RenalLength All Distance measurement cm
Height All Distance measurement cm
Width All Distance measurement cm
Renal Pelvis All Distance measurement cm

Small Parts Calculations

The measurement method for each item is the same as for basic measurement. Measured items are automatically entered into the report.

SAMSUNG HS60 - Small Parts Calculations - 1

NOTE:

It is convenient to calculate each measurement value on the Spectral Doppler image. For information on basic measurement methods, refer to 'Basic Measurements' and 'Common Measurement Methods' in this chapter.

Thyroid Measurement MenuSAMSUNG HS60 - NOTE: - 1

Measurement Menu Item Mode Method Unit
Lt. Thyroid Vol.Rt. Thyroid Vol.Length All Distance measurement cm
Height All Distance measurement cm
Width All Distance measurement cm
Lt. Thyroid FlowRt. Thyroid Flow%StDAllCalculation after distance measurement%
%StAAllCalculation after area measurement%
Auto TracePWDoppler Spectrum trace
Limited TracePWDoppler Spectrum trace
Manual TracePWDoppler Spectrum trace
PSPW Velocity measurement cm/s
EDPW Velocity measurement cm/s
MDPW Velocity measurement cm/s
PIPW Velocity measurement –
RIPW Velocity measurement –
S/DPWContinuous measurement –
Vol.Flow(D)PWCalculate after measuring TAmean, Vesl., and Dist.ml/min
Vol.Flow(A)PWCalculate after measuring TAmean, Vesl., and Areaml/min
Lt. Mass 1–5Rt. Mass 1–5Length All Distance measurement cm
Height All Distance measurement cm
Width All Distance measurement cm

Breast Measurement MenuSAMSUNG HS60 - NOTE: - 2

Measurement Menu Item Mode Method Unit
Lt. Mass 1–10Rt. Mass 1–10Length All Distance measurement cm
Height All Distance measurement cm
Width All Distance measurement cm
Lt. Breast FlowRt. Breast Flow%StD AllCalculation after distance measurement%
%StA AllCalculation after area measurement%
Auto Trace PWDoppler Spectrum trace
Limited TracePWDoppler Spectrum trace
Manual TracePWDoppler Spectrum trace
PSPW Velocity measurement cm/s
EDPW Velocity measurement cm/s
MDPW Velocity measurement cm/s
PIPW Velocity measurement –
RIPW Velocity measurement –
S/DPWContinuous measurement
Vol.Flow(D)PWCalculate after measuring TAmean, Vesl., and Dist.ml/min
Vol.Flow(A)PWCalculate after measuring TAmean, Vesl., and Areaml/min

Testis CalculationsSAMSUNG HS60 - NOTE: - 3

Measurement Menu Item Mode Method Unit
Lt. Testis Vol.Rt. Testis Vol.Length All Distance measurement cm
Height All Distance measurement cm
Width All Distance measurement cm
EpididymisD1 All Distance measurement cm
D2 All Distance measurement cm
Lt. Testis FlowRt. Testis Flow%StDAllCalculation after distance measurement%
%StAAllCalculation after area measurement%
Auto TracePWDoppler Spectrum trace
Limited TracePWDoppler Spectrum trace
Manual TracePWDoppler Spectrum trace
PSPW Velocity measurement cm/s
EDPW Velocity measurement cm/s
MDPW Velocity measurement cm/s
PIPW Velocity measurement -
RIPW Velocity measurement -
S/DPWContinuous measurement -
Vol.Flow(D)PWCalculate after measuring TAmean, Vesl., and Dist.ml/min
Vol.Flow(A)PWCalculate after measuring TAmean, Vesl., and Areaml/min
Lt. Mass 1-5Rt. Mass 1-5Length All Distance measurement cm
Height All Distance measurement cm
Width All Distance measurement cm

Superficial CalculationsSAMSUNG HS60 - NOTE: - 4

Measurement Menu Item Mode Method Unit
Lt. Superficial Vol.Rt. Superficial Vol.Length All Distance measurement cm
Height All Distance measurement cm
Width All Distance measurement cm
Lt. Superficial FlowRt. Superficial Flow%StD AllCalculation after distance measurement%
%StA AllCalculation after area measurement%
Auto Trace PW Doppler Spectrum trace
Limited TracePW Doppler Spectrum trace
Manual TracePW Doppler Spectrum trace
PSPW Velocity measurement cm/s
EDPW Velocity measurement cm/s
MDPW Velocity measurement cm/s
PIPW Velocity measurement -
RIPW Velocity measurement -
S/DPWContinuous measurement -
Vol.Flow(D)PWCalculate after measuring TAmean, Vesl., and Dist.ml/min
Vol.Flow(A)PWCalculate after measuring TAmean, Vesl., and Areaml/min
Vel APW Velocity measurement cm/s
Vel B PW Velocity measurement cm/s
Lt. Mass 1-5Rt. Mass 1-5Length All Distance measurement cm
Height All Distance measurement cm
Width All Distance measurement cm

Musculoskeletal Calculations

SAMSUNG HS60 - Musculoskeletal Calculations - 1

Measurement Menu

The measurement method for each item is the same as for basic measurement. Measured items are automatically entered into the report.

SAMSUNG HS60 - Measurement Menu - 1

NOTE: For information on basic measurement methods, refer to 'Basic Measurements' and 'Common Measurement Methods' in this chapter.

Measurement Menu Item Method Unit
Lt. ShoulderRt. Shoulder#1~#10 Distancemeasurement cm
Lt. WristRt. Wrist#1~#10 Distancemeasurement cm
Lt. KneeRt. Knee#1~#10 Distancemeasurement cm
Lt. AnkleRt. Ankle#1~#10 Distancemeasurement cm

Vascular Calculations

The measurement method for each item is the same as for basic measurement. Measured items are automatically entered into the report.

SAMSUNG HS60 - Vascular Calculations - 1

NOTE:

For information on basic measurement methods, refer to 'Basic Measurements' and 'Common Measurement Methods' in this chapter. For references on measurement items, see 'Reference Manual Part 1'.

Carotid Measurement Menu

Measurement Menu Item Mode Method Unit
Lt. CCA Rt. CCA Lt. Bulb Rt. Bulb Lt. ICA Rt. ICA Lt. ECA Rt. ECA%StD AllCalculation after distance measurement%
%StA AllCalculation after area measurement%
IMT All Distance measurement mm
IMT Mean AllAverage calculation after distance measurementmm
Auto TracePWDoppler Spectrum trace
Limited TracePWDoppler Spectrum trace
Manual TracePWDoppler Spectrum trace
PSPW Velocity measurement cm/s
ED PW Velocity measurement cm/s
MDPW Velocity measurement cm/s
PIPW Velocity measurement -
RIPW Velocity measurement -
S/DPWContinuous measurement
Vol.Flow(D)PWCalculate after measuring TAmean, Vesl., and Dist.ml/min
Vol.Flow(A)PWCalculate after measuring TAmean, Vesl., and Areaml/min
Lt. Subclavian A Rt. Subclavian A Lt. Vertebral A Rt. Vertebral A%StD AllCalculation after distance measurement%
%StA AllCalculation after area measurement%
Auto Trace PWDoppler spectrum trace
Limited Trace PWDoppler spectrum trace
Manual Trace PWDoppler spectrum trace
PS PW Velocity measurement cm/s
EDPW Velocity measurement cm/s
MDPW Velocity measurement cm/s
PIPW Velocity measurement -
RIPW Velocity measurement -
S/DPWContinuous measurement
Vol.Flow(D)PWCalculation after measurement of TAmean, Vesl. Distml/min
Vol.Flow(A)PWCalculation after measurement of TAmean, Vesl. Areaml/min

SAMSUNG HS60 - NOTE: - 1

Auto IMT+

This function allows you to take IMT measurements easily and quickly.

SAMSUNG HS60 - Auto IMT+ - 1

NOTE:

▶ Auto IMT+ is an optional feature of this product. Auto IMT+ is available only under the following conditions:

  • Probe: Linear Probe
  • Application: Vascular – Diagnosis Mode: 2D Freeze Mode

Auto IMT+ Screen

Auto IMT + SAMSUNG 20160621-032528PM Tls 0.19 MI 1.35 2016-06-21 03:25:48 PM CarMax LA3-10AD 3.5 cm 44 Hz [2D] Run 1 Gm 100 DR 112 Map? FA 7 P 90% Min: 100 min Max: 100 min Min: 100 min Max: 100 min Min: 100 min Max: 100 min Max: 100 min Max: 100 min Max: 100 min Max: 100 min Max: 100 min Max: 100 m…

[Figure 8.2 Auto IMT+]

Auto IMT+ Measurement

  1. After checking the probe and the application, start a carotid scan.
  2. Press Freeze to obtain the desired image. Use the trackball to select the image you want to measure the IMT on.
  3. Tap Auto IMT+ on the touch screen. The Auto IMT+ screen will appear.
  4. Use the trackball and the Set button to set a location for IMT measurement.

Measure the length of a specific section. Press and hold the Set button at the starting point and use the trackball to specify the end point. You can change the Near and Far positions of the measured area by using the Change button on the control panel.

  1. Once the measurement finishes, measurement values will be listed in a table.
  2. Use the touch screen, or the dial-button to select the measurement label, the location of the blood vessel, and the direction of blood flow.

Setting Up Measurement Items

On the touch screen menu, you may set up the measurement item, the location of the blood vessel, and the direction of blood flow.

▶ Measurement item: Select measurement items among CCA, Bulb, ICA, and ECA. Use the touch screen button. Direction: Select the blood flow direction either left or right. Use dial-button 2. ▶ Location: Select Prox(Proximal), Mid(Middle), or Dist(Distal) as the location of the blood vessel to measure. Use dial-button 3.

SAMSUNG HS60 - Setting Up Measurement Items - 1

NOTE: Exit Auto IMT+ using following functions:

▶ Change Image Mode and Zoom Annotation, BodyMarker, Patient, SonoView, Report, Setup, Help

Measurement Result

Max: The maximum thickness of the Intima/Adventitia pair. Mean: The average thickness of the Intima/Adventitia pair. SD: Standard Deviation QI: The distance ratio of the measured point in a distance for Quality Index measurement.

SAMSUNG HS60 - Measurement Result - 1

NOTE: Location of measurement result window cannot be changed and it is displayed in the position established before Auto IMT+ measurement.

Applying to the Report

Auto IMT+ measurement results are automatically applied to the report. Report\Auto IMT+ measurement results can be checked.

Auto IMT+ Measurement Analysis

  1. Tapping the Analysis on the touch screen opens Analysis screen.
  2. Select the desired analysis from Framingham/CHD, Risk Factor, Normal IMT, or User Graph by using the trackball and the Set button. The bar that corresponds to the measurement will be displayed on each graph. However, if the measurement is smaller than Framingham/CHD, or Risk Factor, no bar will be displayed.

Tips!

User Graph

You can use User Graph to adjust the graph and analyze the measurement results as you want.

  1. To finish analyzing, tap the Exit button on the touch screen.
  2. The following materials were referred to when analyzing the measurements of Auto IMT+.

Framingham/CHD

Correlation between the Framingham Risk Score and Intima Media Thickness: the Paroi Arterielle et Risque Cardio-vasculair (PARC) Study.

Pierre-Jean Touboul, EricVicaut, Julien Labreuche, Jean-Pierre Belliard, Serge Cohen, Serge Kownator, Jean-Jacques Portal, Isabelle Pithois-Merli, Pierre Amarenco. On behalf of PARC Study participating physicians.

Risk Factor

Mannheim Carotid Intima-Media Thickness Consensus (2004–2006)

P.J. Touboul, M.G. Hennerici, S.Meairs, H.Adams, P.Amarenco, N.Borstein, L.Csiba, M.Desvarieux, S.Ebrahim, M.Fatar, R.Hernandez Hernandez, M.Jaff, S.Kownator, P.Prati, T.Rundek, M.Sitzer, U.Schiminke, J.C. Tardif, A.Taylor, E.Vicaut, K.S.Woo, F.Zannad, M.Zureik

Normal IMT

Simon A, Gariepy J, Chironi G, Megnien JL, Levenson J: Intima-media thickness: a new tool for diagnosis and treatment of cardiovascular risk. Journal of Hypertension 20:159-169, 2002

UE Artery Measurement MenuSAMSUNG HS60 - Normal IMT - 1

Measurement Menu Item Mode Method Unit
Lt. Subclavian A Rt. Subclavian A Lt. Axillary A Rt. Axillary A Lt. Brachial A Rt. Brachial A Lt. Radial A Rt. Radial A Lt. Ulnar A Rt. Ulnar A Lt. SPA Rt. SPA%StD AllCalculation after distance measurement%
%StA AllCalculation after area measurement%
Auto Trace PWDoppler Spectrum trace
Limited Trace PWDoppler Spectrum trace
Manual Trace PWDoppler Spectrum trace
PS PWVelocity measurement cm/s
EDPWVelocity measurementcm/s
MDPWVelocity measurementcm/s
PIPWVelocity measurement-
RIPWVelocity measurement-
S/DPWContinuous measurement
Vol. Flow(D)PWCalculate after measuring TAmean, Vesl., and Dist.ml/min
Vol. Flow(A)PWCalculate after measuring TAmean, Vesl., and Areaml/min

UE Vein Measurement MenuSAMSUNG HS60 - Normal IMT - 2

Measurement Menu Item Mode Method Unit
Lt. Internal Jugular V Rt. Internal Jugular V Lt. Innominate V Rt. Innominate V Lt. Subclavian V Rt. Subclavian V Lt. Axillary V Rt. Axillary V Lt. Brachial V Rt. Brachial V Lt. Cephalic V Rt. Cephalic V Lt. Basilic V Rt. Basilic V Lt. Radial V Rt. Radial V Lt. Ulnar V Rt. Ulnar VVmax PW Velocity measurement cm/s
Dur T PW Time measurement ms
Vesl. Dist PW Distance measurement cm
Vesl. Area PWVolume measurementcm2

LE Artery Measurement MenuSAMSUNG HS60 - Normal IMT - 3

Measurement Menu Item Mode Method Unit
Lt. CIA, Rt. CIA Lt. IIA, Rt. IIA Lt. EIA, Rt. EIA Lt. CFA, Rt. CFA Lt. SFA, Rt. SFA Lt. DF, Rt. DF Lt. Popliteal A Rt. Popliteal A Lt. ATA, Rt. ATA Lt. PTA, Rt. PTA Lt. Peroneal A Rt. Peroneal A Lt. DPA, Rt. DPA Lt. MPA, Rt. MPALt. LPA, Rt. LPALt. Metatarsal A Rt. Metatarsal A Lt. DigitalA Rt. Digital A%StD AllCalculation after distance measurement%
%StA AllCalculation after area measurement%
Auto Trace PWDoppler Spectrum trace
Limited Trace PWDoppler Spectrum trace
Manual Trace PWDoppler Spectrum trace
PS PW Velocity measurement cm/s
EDPW Velocity measurement cm/s
MDPW Velocity measurement cm/s
PIPW Velocity measurement -
RIPW Velocity measurement -
S/DPWContinuous measurement
Vol.Flow(D)PWCalculate after measuring TAmean, Vesl., and Dist.ml/min
Vol.Flow(A)PWCalculate after measuring TAmean, Vesl., and Areaml/min

LE Vein Measurement MenuSAMSUNG HS60 - Normal IMT - 4

Measurement Menu Item Mode Method Unit
Lt. CIV, Rt. CIVLt. IIV, Rt. IIVLt. EIV, Rt. EIVLt. CFV, Rt. CFVLt. PFV, Rt. PFVLt. SFV, Rt. SFVLt. GSV, Rt. GSVLt. Popliteal VRt. Popliteal VLt. LSV, Rt. LSVLt. ATV, Rt. ATVLt. PTV, Rt. PTVLt. Peroneal VRt. Peroneal VLt. MPV, Rt. MPVLT. LPV, Rt. LPVLt. Metatarsal VRt. Metatarsal VLt. Digital VRt. Digital VVmax PW Velocity measurement cm/s
Dur T PW Time measurement ms
Vesl.Dist PW Distance measurement cm
Vesl.Area. PW Volume measurement cm2

Reports

The measurement results are summarized by application, and shown on the screen in a report format.

Viewing Reports

Press the Report button on the control panel to switch to the Ultrasound measure Report screen.

The measurement results are summarized by application, and shown on the screen in a report format.

SAMSUNG HS60 - Viewing Reports - 1

NOTE: Reports are displayed only for the applications that have measurement results.

Page

Pages are divided into Worksheet, Description, Comment, and image for each application; opening a report will show the Preview screen by default. You can go to each section from the Left Menu or Touch; if a section contains large amount of data to display, it will be divided into multiple pages, which you may navigate pages using Touch or dial-button.

Report Preview

It provides report preview before print-out.

SAMSUNG HS60 - Report Preview - 1

Property

Print

Set the type of Printer, Application, Print color, and Page.

Settings

You can set Header & Footer, Logo, Title, Patient Info, and Table Form of a report.

Report Province Worksheet S: Procedure longitudinal Date of birth/age) Indication Step. Physician Ref. Physician Operator LWP Component GA Average BW AKR/DFF GA(LWP) GA(AUR) AC/FL 11x20 122 g (19) g BD(LWP) BD(AUR) BD(15-13) Initial Inlogic Scarble Aortic Para Aorta WEL/LAMP First Memory MS 2.82 0.8…

[Figure 8.3 Report Preview]

Printer

Select a USB Printer connected to the equipment.

Range

Set a page to save the print-out or images. Current Page selects the currently active page and All Applications selects all pages.

Application

Set application to save the Preview screen, printout, or images. Current Application will select applications established in the worksheet, while All Application will select all applications.

Color (Print)

Set the color of report in printout.

Color (Store)

Set the color of image to save images.

Page

Set pages to save the Preview screen, printout, or images. Echo Page will select a landscape-formed report.

Set the header and footer. Checking Show Date in Footer will display the date at the bottom right-hand side.

Report Printer Worksheet SAMSUNG MEDISON ID 0198020-05564444 Date of Birth/Aggs Casider Indicators Drug Physician Ref. Physician Operator LMP GAS(LMP) BOD(LMP) Crude Compass GA AIG(AIG) 17m3d ED(SA) PPM NASLOCK1 AC.FI 132 g/19 g 100x100g MELEMAN Fetal Bioenergy m1 m2 m3 GA DS 2.83 2.83 on Last Total…

[Figure 8.4 Header & Footer]

Set a logo on the top of the report. It can be changed once it is connected to a USB.

Title

Set the title. User-selected title or a title set in the Patient will be shown.

Patient Info.

Set Patient information shown on the page. Only the 1st page shows the Patient information only on the first page.

Table Form

Set the report form. Selection of Brief will show the results only, while selection of 2 Columns will show measure items in the two columns.

Report Preview Worksheet DB 201603-104/05/05 Date of Birth (Page) Indicator Blog Physician Ref. Physician Operator LBP Compost GA Average SPX BASOCH GAL(MP) GAL(AA) 17x3d 172 g x1TB g (No valid) GB BDO(LMP) BDO(AA) 2017-03-13 Greede Single Pure Aberta BILLOWS Total Geometry RST RST RST SA GS 2.83 3.…

[Figure 8.5 Columns]

Editing Report (Worksheet)

When you move the focus to a value that can be edited on a Worksheet, the borders of the edit window will be marked in blue, and Edit mode will start by clicking.

Report Preview Worksheet 2010083-030308PM Indication Diag. Physician Ref. Physician Operator LMP GA(Cm) EDG(GA) Gravida Para Composite GA Average GA(AUA) 9w5d EDG(AUA) 2017-03-03 Aboriginal Extragen EFW HADLOCK AC FL 57 g ≥9 g (2oz ≥9oz) HADLOCK Fetal Biometry Label Value GA CP m1 m2 m3 Method AvUS…

[Figure 8.6 Worksheet]

Preview Worksheet Application Store SR H12 Export Print Exit Main Description Image Comment OB Graph Fetus Compare Default Author Delete Cell Delete Line Prev Next Fetus A Page 1/1

[Figure 8.7 Worksheet - Touch Screen]

SAMSUNG HS60 - Editing Report (Worksheet) - 3

Modify Measurements

After you have edited a value and moved the focus away from the value or pressed Enter on the keyboard, the edited value will be applied. Edited values will be indicated with an asterisk (*) in front of them. To delete a value, click the value you wish to delete; the Delete button will be activated on the touch screen. Press this button to delete the value immediately.

Default Author

Reverts to the author of Setup settings.

Delete Cell

Select and delete a measurement value.

Delete Line

Delete all values with the same label as the selected value.

SAMSUNG HS60 - Delete Line - 1

NOTE: If you change the Author in a Worksheet, the GA value will be changed. The Author you change in a Report is only valid within the Report; the Author of the Setup will be used for calculating the GA when you are taking measurements in Measurement mode.

AV.US

If Composite GA is Average, you may select or exclude GA values from each Label Av.US that have been used for calculation.

Measurement Display Method

The product allows you to measure one measurement item multiple times. However, only the first three measurement results are saved in a report.

When taking measurements for the same item more than once, measurements can be displayed in four ways. On the Edit Report screen, you can specify or change the measurement display method.

Go to Set Up > Measurement > Application > Doppler > Display Absolute Value and select 'On' to display absolute values in the report.

Average

Obtain the average of the measurements and display it on the screen.

Last

Display the last measurement on the screen.

Max

Display the largest value of the measurements on the screen.

Min

Display the smallest value of the measurements on the screen.

Adding Comments

Tap Comment on the touch screen or click Comment in the left-hand menu on the Ultrasound Report screen. A screen in which you can enter opinions will appear.

Tap the bottom of the entry window or the Comment button on the touch screen and a window will open to let you select a comment you have previously entered in Setup. Select Comment in the window and the selected text will be entered at the location of the cursor in the comment entry window.

SAMSUNG HS60 - Adding Comments - 1

NOTE: Comments may be added at Setup > Report > Comment. For more information, refer to 'Report' in 'Chapter 3. Utilities'.

Report Preview Worksheet 20160817-45032PM Indication Diag. Physician Ref. Physician Operator Application OB Comment Main OB Graph Description Image Store SR Exit Comments Format A Page 1 / 3 Images 1

[Figure 8.8 Comment]

Preview Worksheet Application Store SR HL7 Export Print Exit Main Description Image Comment OB Graph Fetus Compare Clear Comments Fetus A Page 1/1

[Figure 8.9 Comment – Touch Screen]

In the Preview screen, tap the Print button on the touch screen or press Print in the left-hand menu on the Report screen. The measurement report for the selected application will be printed on a connected printer.

SAMSUNG HS60 - Print Reports - 1

NOTE: You can change the printer settings for printing measurement reports at Report > Preview > Property > Print. For more information, refer to 'Peripheral Device Settings' in 'Chapter 3. Utilities'.

Saving Reports

In the Preview screen, tap Export on the touch screen. Or press Export in the left-hand side of the Report screen. The Export button is activated only when it is connected to a USB. The Export window will appear and save the report in the external storage media.

The Export window will appear and specify the directory, drive, file name, and file format. Click OK on the screen to save the report. Tap Cancel to cancel.

Export Drive F:\ F:\ ► 19.Printer Driver ► EVE_Image_Capture ► HS50,60 ► HS70A_Image_Capture ► IMAGE ► MDX1 ► R7 ► RMS File Name 20160412-103542AM_OB File Format PDF F:\20160412-103542AM_OB.PDF OK Cancel

[Figure 8.10 Export]

Store SR

Tap Store SR on the touch screen or the Left Menu to save the Measure SR Information.

Images

Select this if you want to attach images to the report. Tap the Image button on the touch screen or press Image in the Left Menu on the Ultrasound Report screen to open a window where you can select images.

Report Preview Worksheet application OB Main OB Graph Description Comment Store SR Exit 20160817-05832PM 2016-06-17 Main OB Graph Description Comment Store SR Exit Fetus A Page 1 / 1 Images 1

[Figure 8.11 Image]

Preview Worksheet Application Store SR HLP Export Print Exit Main Description Image Comment OB Graph Fetus Compare Add Delete Delete All □ ■ ■ Prev Next Fetus A Page 1/1

[Figure 8.12 Image - Touch Screen]

  1. Select images from the thumbnail on the right.
  2. When images are selected, the Add button becomes active on the touch screen. Tap the Add button to attach the selected images to the report. Alternatively, double-click selected images among the thumbnails to attach the associated images.
  3. If you select images attached to a report, the Delete button becomes active so that you may delete attached images. Press the Delete All button to delete all attached images.
  4. You may select 1x1, 2x2, 3x3, or 4x4 for layout.

OB Graph

After taking OB measurements, press Report on the touchscreen or control panel. Tapping OB Graph on the touch screen displays the Graph screen.

Click/tap the Single or Quad button on the screen/touch screen. Select the layout on the graph screen. You can review the graph and trends. To return to the Report screen, tap Preview on the touch screen or the Left Menu.

SAMSUNG HS60 - OB Graph - 1

NOTE: The graph function can only be used with OB reports.

The list of measured items appears on the right side of the screen. If you select an item, a graph for the selected item will appear on the screen.

SAMSUNG HS60 - OB Graph - 2

NOTE:

To execute the graph function, at least one Label containing a Growth Table must be measured, and only a Label that has been measured may display graphs. A graph is created based on the patient ID, LMP and measurement date.

Report Preview Worksheet 20100803-03008PM Indication Diag. Physician Ref. Physician Operator EMP GA(Clin) GA(AUA) 9w5d ESO(GA) EDO(AUA) 2017-03-03 Gravida Alberta Para Ectopic OB Compound GA Average GA(AUA) 9w5d Label Value GP GA EFW 57 g GS 0.56 cm CRL 0.41 cm SPD 0.45 cm FL 0.91 cm AC 5.68 cm 11w5…

[Figure 8.13 OB Graph]

Preview Worksheet Application Store SR HCT Export Print Exit Main Description Image Comment OB Graph Fetus Compare Trend Current User History Manual Trend Select All Unselect All Hide Grid All Fetus Prev Next Fetus A Change Marker 2014-07-06 Page 2 / 6

[Figure 8.14 OB Graph - Touch Screen]

Select a Graph

Use the Trackball and the Set button to select an item from the list.

Single

A graph representing one obstetrics measurement will be displayed.

Quad

A graph representing four obstetrics measurements will be displayed.

Hide Grid

Erase the grids on a graph.

All Fetus

Display graphs for all measured fetuses.

Current Fetus

Display graphs for the fetus currently being measured.

Trend

Tap Trend on the touch screen. The past and present measurement values for a fetus are displayed in the order of study date. It is shown on the graph with different markers for different study dates.

Current

Tap Current on the touch screen. The current measurements for a fetus are displayed by study date.

User History

The past and present measurement values for the fetus are displayed in a table format.

Manual Trend

Display the measurement values manually entered by the user, which are to be displayed on the OB Growth Curve in Trend. Enter manually in Patient window.

Prev

Return to the previous page.

Next

Move on to the next page.

Tips!

Standard Deviation & Percentile

Among the OB information, the Growth table and the typical fetal distribution, for the same number of weeks, are used to determine the following information:

The normal distribution curve. The measurements for an actual fetus or a position in EFW distribution. Whether or not a distribution point is within the normal range.

The number of weeks referenced for the Growth table can be set to LMP, Estab., DD, or Average US GA, under Pctl. Criteria; the typical setting is LMP.

When the LMP is not known or uncertain, or when the difference between the LMP and the Average US GA is substantial, care must be taken, as selecting different Pctl. Criteria can result in a significant difference.

The distribution of the number of weeks in the Growth table for the selected reference is a normal distribution. It is laterally symmetrical around 50% (the average) and it shows the distance from the average as a deviation. The deviation can be represented by Standard Deviation (SD) or Percentile terms.

| Standard Deviation | Percentage | | ------------------ | ---------- | | m-3σ | 0% | | m-2σ | 0% | | m-σ | 68.3% | | m | 68.3% | | m+σ | 0% | | m+2σ | 0% | | m+3σ | 0% |

[Figure 8.15 Distribution of Growth Table for the Selected Week (m: mean, σ: standard deviation)]

SAMSUNG HS60 - Standard Deviation &amp; Percentile - 2

When represented by SD, a point near to the average indicates a value closer to ±0 SD and a point further away from the average indicates a value closer to the maximum or minimum value. The greater part of the range falls within ±3 SD, with ±1 SD representing 68.3% of the entire range. Thus it can be seen that most fetal measurements are tightly clustered around the average value.

The Percentile represents a point in a distribution from 0 to 100 inclusive. Therefore, the average point is represented as the 50th Percentile.

As shown in the figure, the average point corresponds to 0 SD (that is, the 50th Percentile). If a point is in the range between -1 SD and +1 SD, it falls within 68.3% of the entire range. This means that the point falls within the range between 16 and 84.

Further, if a point is in the range between -2 SD and +2 SD, it falls within 95.5% of the entire range. Thus, the point falls in the range between 3 and 97.

The SD and Percentile are interchangeable. Percentile can be used when a fetal measurement ranking is desired, while SD can be used when the distance between actual fetal measurements and the average measurement is sought.

While the range of Growth table references that are primarily used with OB measurement data varies depending on the user, the typical range accepted by most users is as below:

When references are created based on SD:

  • -2.0 SD - +2.0 SD (when converted to Percentile: 2.28 Percentile - 97.72 Percentile)
  • -1.5 SD - +1.5 SD (when converted to Percentile: 6.68 Percentile - 93.32 Percentile)
  • -1.0 SD - +1.0 SD (when converted to Percentile: 15.87 Percentile - 84.13 Percentile)

When references are created based on Percentile:

  • 2.5 Percentile – 97.5 Percentile (when converted to SD: -1.96 SD – 1.96 SD)
  • 5.0 Percentile - 95.0 Percentile (when converted to SD: -1.645 SD - 1.645 SD)
  • 10.0 Percentile - 90.0 Percentile (when converted to SD: -1.288 SD - 1.288 SD)

Description

Tap Description on the touch screen. OB and Gyn applications have their own preset items; for other applications, only user-added items are available.

General OB

This item only becomes active when OB measurement is available. Tap the General OB button on the touch screen and you can select a description for the selected item.

Early OB

This item only becomes active when OB measurement is available. Tap the Early OB button on the touch screen and you can select a description for the selected item.

Biophysical Profiles

5 items of Breathing, Movement, Tone, AFV, and NST may be left blank or set as 0, 1, or 2; the sum of each item will be displayed as Total.

SAMSUNG HS60 - Biophysical Profiles - 1

NOTE: Biophysical Profile is activated only when OB measurement values exist.

Default

This value has been preset in advance by the user.

Save as Default

Save the values currently set on the screen as default values.

Clear

Delete all items.

Fetus Compare

In the OB Study Information screen, select the Number of Fetuses to enable measurement for each fetus when taking OB measurement. Tap the Fetus Compare button on the touch screen and measurement for each fetus is displayed.

Report Preview Worksheet 2010-06-17 05:32:2PM Indication Diag. Physician Ref. Physician Operator LMP GA(LMP) EDD(LMP) Gravida Pure Composite GA Average GA(AUA) 7x93d EDD(AUA) 2017-01-31 Alberta Octopic OB General Descriptions Fetal Brain Fetal Description Lateral Ventricles Fetal Position Cist Magne…

[Figure 8.16 Description]

Preview Worksheet Main Description Image Comment OB Graph Fetus Compare Store SR General OD Biophysical Profile Early OB Default Save as Default Exit Clear Next Fetus A Page 1/3

[Figure 8.17 Description – Touch Screen]

Closing Reports

Tap Exit on the touch screen or in the Left Menu. Alternatively, press the Report button on the control panel.

Image Managements

Cine/Loop 9-3 ■ Annotating Images.... 9-5

Annotation 9-5

BodyMarker 9-10

Saving, Playing and

Transferring Images 9-12

Saving Images....9-12

Playing Images....9-13

Transferring Images 9-14

■ Printing Images....9-15

Printing Images 9-15

SonoView Mode 9-16

Exam List 9-17

Review – Exam Mode 9-19

Review – Compare Mode......9-24

DICOM Q/R 9-31

Cine/Loop

Images are automatically saved in the memory during scanning. The saved images are useful for patient diagnosis and review.

The saved images can be in Cine or Loop, depending on the diagnosis mode.

2D Cine: These are images temporarily saved in all diagnosis modes except M Mode and Spectral Mode. Trace Cine: Images that are saved in M Mode and Spectral Mode.

OB SAMSUNG 2016012B-111557AM Tts 0.5 MI 1.4 2016-01-28 11:32:02 AM 1st Trimester LAE-18SD 4.D cm 47 Hz [2D] Gen Gm 76 DR 124 Map 7 FA 5 P 94% Freeze Pointer 47 / 96 Sound/Point A Set Set 1 Stand/Point Sound/Point B Sound/Point A 1 Stand/Point 2 Stand/Point 3 Stand/Point Images 5

[Figure 9.1 Cine]

Starting and Finishing Image Review

During scanning, press the Freeze button on the control panel. The scanning is stopped and the system switches to the image review mode screen.

Press the Freeze button again to return to the scan mode.

How to Review Images

Move the cursor to the Cine or Bar in the user information area to review an image. You can search through saved images by moving the cursor with the trackball. The total number of saved images and the number of the image currently being reviewed are shown next to the bar.

Selecting Loop

Select an image to play by pressing the Change button in the control panel.

The touch screen menu is changed when images are reviewed.

2D ClearVision < Off > Strain+ Cine Play L/R Flip U/D Flip Rotation < 0° > Cine Speed < 100% > Edge Enhance < -3 > Trim Start 1 Trim End 28 Image Size 95 Gray Map 2 Chroma Map Off

[Figure 9.2 Reviewing Images - Touch Screen]

Cine Play

Tap Cine Play on the touch screen. You can stop or resume playback of an image by tapping the button.

Cine Speed

Use the Cine Speed button on the touch screen to adjust the automatic playback speed of 2D Cine or Trace Cine. Speed may be adjusted between 6-300%.

SAMSUNG HS60 - Cine Speed - 1

NOTE: For an explanation of the other items on the touch screen, refer to Basic Mode in 'Chapter 7. Diagnosis Mode'.

Reviewing Image in Multi-image Mode

Only the images in an active area can be reviewed. To review images in another area, change the active area by using the Dual or Quad button on the control panel.

Annotating Images

Annotation

Enter or display text, Arrow, or BodyMarker on an image. This function is useful for differentiating or marking a diagnosis area.

SAMSUNG HS60 - Annotation - 1

Starting Annotation Mode

Press the Text or Arrow button on the control panel.

MSK SAMSUNG 20160610-11:27:05AM General LA3-16A 4.0 cm 31 Hz [20] Gen Gn 32 DR 126 Map 7 FA 5 P 90% Text Arrow Gera/Test 4 EFW Result 5 TFW Measure 6 Est 1 Scale/Test 2 Scale/Test 3 Scale/Test TIs 0.36 MI 1.36 2016-06-10 11:34:24 AM Image 2

[Figure 9.3 Annotation Mode]

SAMSUNG HS60 - Starting Annotation Mode - 2

Typing Text

Press the Text button in the control panel and enter text directly with the keyboard, or select predefined text on the touch screen.

You can move the cursor by using the trackball.

SAMSUNG HS60 - Typing Text - 1

Text Mode in Soft Menu

1st Trimester Change Lib. Keyboard Arrow Set Home Home Exit Layer A Rt Lt Proximal Middle Distal Posterior Transverse Sagittal Coronal Uterus Endometrium Cervix Ovary Myoma Placenta Amnion Yolk Sac Gestational Sac Fetal Pole < 1/2 > Delete All Words Delete Last Word Enter Font Size 12

[Figure 9.4 Screen Keyboard]

Change App.

Tap the touch screen or use the dial-button to change application. The text list will change depending on the selected application.

Keyboard

Tapping the 📄 button on the touch screen opens the on-screen keyboard.

Arrow

You can enter an arrow in a place you want over an image.

Delete Last Word

Erase the last entered text. Alternatively, use the Annotation key on the keyboard.

Delete All Words

All of the entered text has been erased. Alternatively, use the Delete All key on the keyboard.

SAMSUNG HS60 - Delete All Words - 1

NOTE: Selecting Setup > Annotation > Select Library allows you to edit the entire page.

For a more detailed description, refer to 'Chapter 3. Utilities'.

Home

When tapping the Home button on the touch screen, it is moved to the established cursor location by Set Home button.

Set Home

Set the initial cursor position when Annotation mode starts. Place the cursor on the screen and tap Set Home on the touch screen.

Layer

Set Layer A and B.

Font Size

Select the font size to use. Select a value between 8 and 72 by using the dial-button on the touch screen.

SAMSUNG HS60 - Font Size - 1

Deleting Text

Press the Clear button on the control panel. All the text entered on the screen will be deleted.

SAMSUNG HS60 - Deleting Text - 1

Exiting Text Mode

Press the Exit button on the control panel or tap the Exit button on the touch screen.

Arrow Mode

You can enter an arrow over an image. This function is useful for differentiating or marking a diagnosis area.

MSK SAMSUNG 20160610-112705AM General LA3 16A 4.8 cm 51 Hz [2D] Gen Gn 32 DB 126 Map7 FA 5 P 90% (buA3.40M/FV 0.25%) Freeze 1525 / 1525 SunRfree 4 E/W Result 5 E/W Measure 6 Test Arrow Est 1. SunRfree 2. SunRfree 3. SunRfree Image 1 Tls 0.36 MI 1.36 2016-06-10 11:34:54 AM

[Figure 9.5 Arrow Mode]

Entering Arrow

  1. When pressing the Arrow button on the control panel, it is converted to the entry mode. Or press the Arrow button in the keyboard.
  2. Use the dial-button's Arrow Type to select the type of arrow you want.
  3. Move the arrow to the desired position by using the trackball.
  4. To adjust the size of the arrow, use the dial-button's Arrow Size.
  5. To adjust the rotation angle of the arrow, use the dial-button's Rotate Arrow.
  6. Press the Set button to finish. Press Exit to cancel.

SAMSUNG HS60 - Entering Arrow - 1

Arrow and Pointer Button

Pointer function is available in Annotation mode.

Deleting Arrows

Press the Clear and Delete All Arrows button on the control panel to delete all arrows displayed on the screen. To delete the last arrow entered, tap Delete Last Arrow on the touch screen.

Exiting Arrow Mode

Press the Exit button on the touch screen or control panel.

BodyMarker

Enter a BodyMarker over an image. This function is useful for differentiating or marking a diagnosis area.

Entering BodyMarker Mode

When pressing Marker/Ref Knob on the control, it is converted to BodyMarker entry mode and the touch screen shows BodyMarker.

Small Parts SAMSUNG 20160610-112705AM Breast LAS-16A 4.0 cm 51 Hz [28] Gen Gm 40 DB 126 Map7 FA 5 P 90% [0xA3, HSPV, 5x727] Probe Body Marker ScorePaint 4 Sun Edd 1 ScorePaint EPW Result 5 2 ScorePaint EPW Measure 6 3 ScorePaint Images 7

[Figure 9.6 BodyMarker Mode]

Inserting BodyMarker

  1. BodyMarkers will appear on the touch screen.

The types of BodyMarker shown on the touch screen vary depending on the selected application. Up to 19 BodyMarkers can be listed on the screen at one time.

When more BodyMarkers are provided, use the > button on the touch screen to navigate the pages.

  1. Tap the touch screen button or dial button for the BodyMarker you want; the BodyMarker will then be displayed on the image.
  2. When pressing Change Lib, it can be immediately changed to a desirable application.
  3. Select a desirable probe shape by using the Probe Type dial-button.
  4. Adjust cursor angle by using the Rotate Probe dial-button or the Angle button on the control panel.
  5. Adjust the cursor size by using the Size dial-button.
  6. Set the initial cursor position when BodyMarker starts. Place the cursor on the screen and tap Store Probe Position on the touch screen.
  7. To finish entering BodyMarkers, press the Set or Exit button on the control panel. To cancel it, press Clear on the touch screen or tap the Delete button on the touch screen.

Changing BodyMarker Position

  1. Press the Change button on the control panel.
  2. Move the BodyMarker to a desired position by using the Trackball.
  3. Press the Set button on the control panel again to confirm the new position.

Deleting a BodyMarker

Press Clear on the touch screen or tap the Delete button on the touch screen.

Exiting BodyMarker Mode

Tap the Exit button on the control panel or touch screen.

SAMSUNG HS60 - Exiting BodyMarker Mode - 1

NOTE: Go to Setup > BodyMarker > Library to set the library of BodyMarker. For a more detailed description, refer to 'Chapter 3. Utilities'.

Saving, Playing and Transferring Images

Saving Images

SAMSUNG HS60 - Saving Images - 1

WARNING: You must always enter the patient ID, because all images are saved according to patient ID. Failure to enter a patient ID may result in a loss of and/or critical errors in previously saved images.

The saved images are displayed in the thumbnail area.

Saving Image

If no patient information has been entered, a Temp ID will be created and saved. The saved images can then be edited and managed in SonoView mode.

Saving (Still Image/Multi Frame Image)

Use the Store Clip function of U1-6 button to save it. For a detailed description for Store/Print settings, refer to 'Chapter 3. Utilities'.

When frozen, specify the range of the image you want to save by using the trackball or the Trim Start and Trim End buttons on the touch screen, then tap the configured U1-6 buttons to save the Cine image. Live Mode works as shown below according to settings. For information about the settings, please refer to 'Chapter 3. Utilities'.

If patient information does not exist, saving Cine in Freeze Mode will create a Temp ID for saving.

If all frames are saved in Live Mode, the saving process is automatically finished according to a predefined time.

The saved images are added to the thumbnail list on the right side of the screen.

Playing Images

You can play the saved images in SonoView and Diagnosis Modes.

SAMSUNG HS60 - Playing Images - 1

Playing Images in SonoView

SAMSUNG HS60 - Playing Images in SonoView - 1

NOTE: Refer to 'SonoView' in this chapter.

SAMSUNG HS60 - Playing Images in SonoView - 2

Viewing Images in Diagnosis Mode

Use the Pointer button on the control panel. Note that this function is available only when there are images saved in the thumbnail list. Press the Pointer button and the cursor will appear on the screen.

Transferring Images

HS50/HS60 allows you to transfer images to a PACS system that supports DICOM. You can transfer all saved images automatically, or select a desired image and transfer it manually. For information on the DICOM server settings and DICOM operations, please refer to 'Connectivity Settings' in 'Chapter 3. Utilities'.

SAMSUNG HS60 - Transferring Images - 1

Transferring Images in Diagnosis Mode

You can transfer images automatically. Images are transferred by using the storage server transmission method in Setup > Connectivity > DICOM. Please refer to "Connectivity Settings" in 'Chapter 3. Utilities' of this manual.

SAMSUNG HS60 - Transferring Images in Diagnosis Mode - 1

Transferring Images in SonoView

You can transfer images manually. The following two methods are available:

Sending Exam

Send all images for an exam.

  1. Select an exam from the Exam List.
  2. Click the Send button on the left side of the screen. All images for the selected exam will be sent.

Sending Selected Images

Select a desired image from among the images for an exam and send it out.

  1. Select the image in the SonoView screen.
  2. Click the Send button on the left side of the screen. The selected images will be sent.

Printing Images

SAMSUNG HS60 - Printing Images - 1

NOTE:

Use it after establishing functions in Setup > Peripherals > Printer. Configure the Store/Print functions in Setup > Customize > Buttons before use.

Printing Images

Press the U1-6 buttons on the control panel. Images are printed via an echo printer. For information on how to set up a printer, please refer to 'Chapter 3. Utilities'.

SonoView Mode

This is the HS50/HS60's integrated image management program. It provides image saving/filing, preview, delete, and other PC-compatible export features.

The image file types used in this product follow the international standard DICOM (Digital Imaging and Communication in Medicine). As a result, the PACS (Picture Archiving Communication System) can be implemented without any additional costs, and it's easy to exchange image files with other hospitals or equipment.

This product supports the Bitmap file format (.bmp), which is commonly used on standard PCs, ensuring easier exchange of image data.

Launching SonoView Mode

Press the SonoView button on the control panel. This will launch the SonoView screen.

If there are saved images available for the current exam, the information and saved images for the exam will appear when SonoView Mode starts.

SAMSUNG HS60 - Launching SonoView Mode - 1

WARNING:

Before saving images or using SonoView Mode, you must register the patient information. All diagnosis information in the product is saved and managed for each patient ID. As a result, saving images without entering a patient ID may result in a loss of and/or critical errors in previously saved images.

Exam List

Appears when the SonoView button is pressed. Or tap Exam List in Review Mode to see the exam list.

Exam List H00 Period Manual: YYYY-MM-DD ~ YYYY-MM-DD Search Hide Patient ID Patient Name Exam Date Application Image Size SR EC Q Description Lock 20160704-023655PM 2016-07... CB 1 89.1 KB 20160704-094901A... 2016-07... CB 1 87.2 KB 20160704-091130A... 2016-07... CB 1 99.0 KB 20160701-102246A... 201…

[Figure 9.7 Exam List]

Enter search criteria at the top of the Exam List screen, and press Search. Search results will be listed on the screen.

You can select an exam from the list and examine, delete, or send it.

Refer also to 'Printing Images' and 'Transferring Images via DICOM' later in the document.

You can select the data storage location. HDD, Media, and Q/R are provided.

SAMSUNG HS60 - Exam List - 2

Hides the Exam list.

SAMSUNG HS60 - Hide Search - 1

Shows hidden Exam list.

Backup Exam

Gets activated when selecting an exam in HDD. Continue to back up the selected exam. Select a drive to back up to and press Yes to continue the backup process.

Restore Exam

Gets activated when selecting an exam from USB storage or CD/DVD. Load the selected exam to HDD.

Review

When one or more exams are selected, the button is activated. The review screen for the selected exams will open. For a more detailed description, refer to 'Review Exam Mode'.

Continue

Is activated when an exam from the last 24 hours is selected. This allows you to modify the exam.

Review – Exam Mode

Press Exam in the upper left corner of the screen.

In the Exam Mode, you can review the current or saved exam.

The image that is selected on the screen will be highlighted with a white border.

SAMSUNG HS60 - Review – Exam Mode - 1

Exam Mode Screen

Exams for each patient ID are displayed by date in a tree structure on the left-hand side of the screen. The number represents the number of saved images. To show or hide exams, use the trackball and the Set button to select a desired ID.

SonoView Exam Compare Exam List Current Exam 20160610-112705AM 2016-09-16:17 Close Close All Exit 2016-09-16 Images 7

[Figure 9.8 Exam Mode]

Exam Compare Pan Reset Select All Unselect All Exam List Current Exam Favorite Delete Exit Send Export Mobile Export Print Page 1/2

[Figure 9.9 Exam Mode - Touch Screen]

SAMSUNG HS60 - Exam Mode Screen - 3

Exam Select

Use the trackball and the Set button to select a desired exam from the list on the left-hand side of the screen. The selected exam will be marked on the list in blue. The saved image will also be displayed on screen.

Reviewing the current exam

Click Current Exam. The current exam and its images are displayed on the screen. This button is only enabled when the patient ID is registered. Exams brought from the ExamList can be closed by using the Close or Close All button.

Reviewing exams performed within the last 24 hours

Double-click an image. The exams that were performed within the last 24 hours and their images are displayed. The first performance date of the exam appears in the feedback area.

You can place measurements, annotations, and BodyMarkers on the loaded exam screen. In addition, you can update the exam with new image scans.

Reviewing exams performed prior to the last 24 hours

Double-click an image. The exams that were performed prior to the last 24 hours and their images are displayed. The first performance date of the exam appears in the feedback area.

You can place measurements, annotations, and BodyMarkers on the loaded exam screen. However, you cannot update the exam with new image scans.

SAMSUNG HS60 - Reviewing exams performed prior to the last 24 hours - 1

Exam Scroll

The image of the previous or next page is displayed on the screen. Access by rotating the Page dial-button on the touch screen. Rotating the dial-button to the left displays the previous page image, while rotating it to the right displays the next page image.

However, this button may not be used when the number of exams saved is less than the number of images that appear on a page under the current layout.

SAMSUNG HS60 - Exam Scroll - 1

Closing Exam Review

Tap Close on the touch screen. To close all exams in the list, click the Close All button.

SAMSUNG HS60 - Closing Exam Review - 1

Pan

You can use the Set button to move the image or scan within the selected image layout.

SAMSUNG HS60 - Pan - 1

Reset

Reset the selected image or scan to the initially saved screen.

SAMSUNG HS60 - Reset - 1

Select All

All images in the current exam will be selected.

SAMSUNG HS60 - Select All - 1

Unselect All

All images in the selected exam will be deselected.

SAMSUNG HS60 - Unselect All - 1

Favorite

After selecting an image in the Exam SonoView Mode, you'll be able to use the Favorite button on the touch screen.

When you select a Favorite, it will be displayed as ★ in the top right-hand corner of the thumbnail image.

SAMSUNG HS60 - Favorite - 1

Delete

Delete the selected image.

SAMSUNG HS60 - Delete - 1

Zoom

Use by rotating the Zoom dial-button on the touch screen. You can adjust the selected images between 3 and 200. This appears when an image is selected.

SAMSUNG HS60 - Zoom - 1

Page

Run by rotating the Page dial-button on the touch screen. Move images of the selected exam.

Layouts

You can adjust the number of images displayed on the screen. Use the touch screen button that represents the layout. Up to 9 images (3×3) can be compared at the same time.

The numbers shown in the layout section indicate the column and row of where an image will be displayed on the screen. You can change the numbers shown in the layout section to customize the layout.

Displaying in Full Screen

Place the cursor on the image and double click the Set button to display the thumbnail loading screen in Scan Mode.

Reviewing 3D Images

If the saved image is 3D, the 3D indicator appears at the bottom of the image. Double clicking the screen will start 3D View for image review.

Cine play

Tap the Cine Play button on the touch screen if the saved image is Cine. You can use Play, Pause, and Stop to navigate the image forwards and backwards.

Review – Compare Mode

Press Compare in the upper left corner of the screen. In Compare Mode, you can select the images related to an exam to compare and review them. The image that is selected on the screen will be highlighted with a blue border.

SAMSUNG HS60 - Review – Compare Mode - 1

Compare Mode Screen

As in Exam Mode, exams for each ID appear on the screen. In addition, images for the selected exam are displayed in thumbnail format.

SonoView Exam Compare Exam List Current Exam 20160618-112705AM [2016-06-10 (7)] Close Close All Exit Image 3

[Figure 9.10 Compare Mode]

Exam Compare Pan Reset Select All Unselect All Exam List Current Exam Favorite Delete Exit Send Export Mobile Export Print Image Scroll Thumbnail Scroll

[Figure 9.11 Compare Mode - Touch Screen]

All functions except *Page and the details below are the same as those in Exam Mode.

SAMSUNG HS60 - Compare Mode Screen - 3

Select an Image

Use the trackball and the Set button to select an image from the thumbnail list. The selected image is highlighted in blue in the list. Select a location on the screen where the image will be displayed and then the selected image will appear.

SAMSUNG HS60 - Select an Image - 1

NOTE: Only scanned data can be loaded into the image area.

SAMSUNG HS60 - Select an Image - 2

Thumbnail Scroll

Images of the previous or next pages are displayed in the thumbnail list. Select the desired image by scrolling with the trackball or using the Thumb Scroll dial-button on the touch screen. Rotating the dial-button to the left displays the previous page's images in the thumbnail list. Rotating it to the right displays the next page's images in the thumbnail list.

Image Scroll

The image of the previous or next page is displayed on the screen. Select the desired image by using the trackball or using the Image Scroll dial-button on the touch screen.

Mobile Export

Mobile Export ① Selected Files Movie 3 Image 2 SR (No Data) ② Connection Status Disconnected. ③ Stand by ④ QR Code ⑤ Send Close

[Figure 9.12 Exam Mode – Mobile Export]

① Selected Files: It shows types of selected images.

When selecting SR checkbox, it will only be transferred when the file to be transferred contains an SR.

② Connection Status: The phone number of the connected smartphone (if connected via Wi-Fi) will be displayed. ③ Stand by: Displays data conversion and transfer status. ④ QR Code: Use the smartphone's QR code scanner to download the Mobile Export application. ⑤ Send: Send the selected images to the smartphone. ⑥ Close: Close Mobile Export.

SAMSUNG HS60 - Mobile Export - 2

NOTE:

▶ Mobile Export is an optional feature of this product. Images that can be transferred through the Mobile Export are available only for acquired still image or recorded video. Enter the clinic name in the system setting. The clinic's name will be displayed at the bottom of the application screen when you run the Mobile Export application.

SAMSUNG HS60 - NOTE: - 1

Preparation

To use Mobile Export, the system and your smartphone need to be connected via Wi-Fi or a USB data cable. You can use the USB Wi-Fi Dongle Key to set up Wi-Fi on the system.

SAMSUNG HS60 - Preparation - 1

Printing Images

  1. Press the Print button. The Print window will be displayed.
  2. Select the type, printing direction, and options for the printer.
  3. Click the Print button to print the image. Click Close to cancel.

SAMSUNG HS60 - Printing Images - 1

Canceling a Print Job in Progress

To cancel a print job in progress, use Setup > Peripherals > Peripherals > Printer > Printer Setting. Select the printer with the print job you want to cancel, and press the Clear Print Setting button. For more information, refer to 'Chapter 3. Utilities' in this manual.

SAMSUNG HS60 - Canceling a Print Job in Progress - 1

NOTE: If Thermal Printer is selected, Include Header and Include Page Numbers will be inactive, and headers and page numbers will not be printed on the pages.

Print Printer Sony UP-D897 Setup Patient Info Orientation Patient Info Preview Portrait Show Landscape Page All Format Layout Images and Report Column 1 - + Images Only Row 1 - + Report Only Order Options Image → Report Copies 1 - + Report → Image White Background 1/1 Print Close

[Figure 9.13 Image Print]

SAMSUNG HS60 - Canceling a Print Job in Progress - 3

Transferring Images via DICOM

Transfer the selected image and measurement data via DICOM. The icon is enabled only when an image is selected. The icon is disabled in a system where DICOM is not enabled.

  1. Select an image and click the Send button on the screen. The DICOM Storage window will appear.
  2. Press the Send button to transfer the selected image to the DICOM server. Click Close to cancel.

Send DICOM Storage Service Name AE Title Host Ping Verify Storage CONQUESTSRV1 10.50.41.114 Success Success Verify Send Close

[Figure 9.14 DICOM Storage]

SAMSUNG HS60 - Transferring Images via DICOM - 2

Transferring Images

  1. Press the Export button. The Export window will open.
  2. Specify the various parameters, such as directory, drive, filename, and file format.

Select the Create Patient Folder(s) checkbox to automatically create folders using patient information. If the Hide Patient Information checkbox has been selected, patient information is not displayed. You can select Low, Mid, or High for Image Quality.

  1. Click the Export button to start a transfer. Click the Close button to cancel.

Export Drive F:\Available Size 11.1 GB Estimated Size 202.5 KB F:\EVE_Image_Capture HS50,60 HS70A_Image_Capture MDX1 NPKI R7 RS80A SanDiskSecureAccessV2 File Name File Format JPEG(Lossy) ✓ Create Patient Folder(s) Image Quality Low Mid High ✓ Hide Patient Information Export Close

[Figure 9.15 Image Export]

SAMSUNG HS60 - Transferring Images - 2

Exiting SonoView

Click the Exit button on the screen. Alternatively, you can press the SonoView button or the Exit button on the control panel to exit SonoView Mode.

DICOM Q/R

At least one server should be registered in the DICOM Q/R settings.

SAMSUNG HS60 - DICOM Q/R - 1

NOTE: Before using this feature, make sure that DICOM Q/R is properly configured. To configure DICOM Q/R, please refer to 'Chapter 3. Utilities' and configure Setup > Connectivity > DICOM functions before use. There is no limit on the number of DICOM Q/R servers you can register.

SAMSUNG HS60 - DICOM Q/R - 2

Run DICOM Q/R

Retrieve an image from the selected server by following this process:

  1. After entering the ID in the Patient window, register or start an exam.

In the SonoView mode, enter an Exam List and select the combobox to Q/R.

  1. Enter the Patient ID, Accession Number, or Last Name as a search term.

Alternatively, search by selecting the modality you wish to find. You may select MR, CT, Mammo, US, DR, or PET for the modality. You may search by designating a period. Select Period. Select either Today, Last Week, Last Month, or Manual in the combo box. If Manual is selected, you do not have to select date separately.

  1. Press the Search button to search.
  2. Patient ID, Patient Name, Modality, Exam Date, Accession Number, Description, and Series Count will appear on the Study List search result.
  3. Up to three studies can be selected from the Study List of the same Patient ID.
  4. Select a study on the Study List to search within a series. Modality, Exam Date, Description, Series No., Image Count, and Status will appear on the Series List search result.
  5. After searching for Series, select the Series you wish to retrieve. You may select or deselect up to 10 series by using the Select All checkbox. Click Retrieve. If 10 series are selected, no additional series can be selected.

Exam List Q/R Patient ID 1 Exam Data Manual YYYY-MM-DD - YYYY-MM-DD Modality MR CT Mammo US DR PET Search Hide Selected: 0 (Choose Up to 3) Total Queries: 0 Patient ID Patient Name Exam Date Modality Description Accession Number Series Count Selected: 0 (Choose Up to 18) Total Queries: 0 Modality Ex…

[Figure 9.16 DICOM Q/R]

SAMSUNG HS60 - Run DICOM Q/R - 2

Retrieval Data Manager

  1. Press Retrieval Data Manager to display the Retrieved Data Manager window.
  2. In the Retrieved Data Manager window, select the series by using the checkbox.

SAMSUNG HS60 - Retrieval Data Manager - 1

NOTE: If you have not started the diagnosis, select the series in the Data Manager window by using the checkbox and press Delete to delete. Locked exams cannot be deleted by using the checkbox.

  1. Press the SonoView button to view the selected exam image in the SonoView window.
  2. This function can be used to compare data by pressing Compare.
  3. Checking Show Only Selected will show the selected exams only.
  4. Tap Close on the screen.

Retrieval Data Manager Show only selected Selected : 1 Patient ID Patient Name Modality Exam Date Description Series #Retrieve date Images Lock 12-05-2014-0002 US 2014-12-05 1 2016-05-02 3 Delete SonoView Close Total Series : 1

[Figure 9.17 Retrieval Data Manager]

Table of contents Click a title to access it
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : SAMSUNG

Model : HS60

Category : Ultrasonic cleaner