Product Type Laser Displacement Sensor
Model HG-C1050-P
Brand Panasonic
Measuring Range 50 mm
Accuracy ±0.1% of F.S.
Resolution 0.5 µm
Light Source Red laser diode, 650 nm
Laser Class Class 2
Output Type PNP
Supply Voltage 12–24 VDC
Power Consumption 50 mA max
Dimensions (L×W×H) 20 × 44 × 25 mm
Weight Approx. 35 g
Operating Temperature −10 to +50 °C
Ingress Protection IP67
Housing Material Stainless steel / resin
Cable Length 2 m
Setting Method Teach-in via button
Display 2-digit LED

Frequently Asked Questions - HG-C1050-P PANASONIC

How do I set the measurement range on the HG-C1050-P?
To set the measurement range, press and hold the Teach button for 2 seconds until the LED flashes. Then place the target at the desired reference position and press the button again to store the setting.
What is the output type of this sensor?
The HG-C1050-P features a PNP output (open collector). It can be connected to most PLCs with PNP input modules.
Can I use this sensor for transparent object detection?
Yes, the laser displacement sensor can detect transparent objects, but accuracy may depend on the object's surface and reflectivity. Use a stable mounting setup for best results.
What is the laser class and is it safe for eyes?
The sensor uses a Class 2 laser (650 nm). It is safe for accidental exposure but avoid direct eye contact for prolonged periods. Do not stare into the beam.
How do I clean the lens?
Clean the lens gently with a lint-free cloth and isopropyl alcohol. Avoid abrasive materials that could scratch the optical surface.
What is the power supply requirement?
The sensor requires a 12–24 VDC power supply. Ensure the power source can deliver at least 50 mA per sensor.
How to connect the sensor to a PLC?
Connect the brown wire to +V, blue wire to 0V, and black wire (output) to the PLC input. For PNP, the output is active high.
What is the response time?
The response time is typically 0.5 ms for the analog output and 1 ms for the digital output. This allows high-speed measurement.
Can I use a longer cable than the supplied 2 m?
The sensor can be used with extension cables up to 10 m total length. Use shielded twisted-pair cable to minimize electrical noise.
Where can I download the manual?
The full user manual in PDF format is available for free download on notice-facile.com or from the Panasonic support website.

User questions about HG-C1050-P PANASONIC

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Uncategorized in PDF format for free! Find your manual HG-C1050-P - PANASONIC and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. HG-C1050-P by PANASONIC.

USER MANUAL HG-C1050-P PANASONIC

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : PANASONIC

Model : HG-C1050-P

Category : Uncategorized