LINCOLN ELECTRIC

FlexCut 125 - Welding machine LINCOLN ELECTRIC - Free user manual and instructions

Find the device manual for free FlexCut 125 LINCOLN ELECTRIC in PDF.

📄 58 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice LINCOLN ELECTRIC FlexCut 125 - page 4
Pick your language and provide your email: we'll send you a specifically translated version.
Product TypePlasma Cutter
BrandLincoln Electric
ModelFlexCut 125
Input Voltage120/240 V AC, 1 Phase, 50/60 Hz
Input Current20 A at 120 V, 15 A at 240 V
Output Current Range20 – 125 A
Duty Cycle60% at 125 A (40% at 240 V input)
Cutting Capacity (Mild Steel)Up to 1/2 in (12.7 mm) at full power
Severance CutUp to 5/8 in (15.9 mm)
Gas RequirementCompressed air, 4.5 scfm at 60 psi (0.4 MPa)
Weight33 lb (15 kg)
Dimensions (H x W x D)18 x 9 x 14 in (457 x 229 x 356 mm)
Pilot ArcYes, for grid cutting
Dual VoltageAuto-connect, 120 V and 240 V
CNC InterfacePort for mechanized cutting
Overload ProtectionThermal and current overload
CertificationsCSA, CE
Included ConsumablesElectrode, nozzle, shield, swirl ring
Warranty3 years on power supply, 1 year on torch
MaintenanceInspect and replace consumables; clean air filter monthly
Spare Parts AvailabilityAuthorized distributors and online store

Frequently Asked Questions - FlexCut 125 LINCOLN ELECTRIC

What thickness of metal can the FlexCut 125 cut?
At full output, the FlexCut 125 can cut mild steel up to 1/2 inch (12.7 mm) and sever up to 5/8 inch (15.9 mm).
Does the FlexCut 125 run on 120V or 240V?
It has dual voltage auto-connect capability. It automatically adjusts to either 120 V (20 A) or 240 V (15 A) input.
What gas is required for the FlexCut 125?
It uses compressed air at a flow of 4.5 scfm and pressure of 60 psi (0.4 MPa). Clean, dry air is recommended.
How do I change consumables on the FlexCut 125?
Disconnect power, remove the torch shield, unscrew the old nozzle, electrode, and swirl ring. Install new parts in reverse order. Torque to specifications in the manual.
What is the duty cycle of the FlexCut 125?
At 125 A output, the duty cycle is 60% on 240 V input and 40% on 120 V input. This means you can cut for 6 minutes out of 10 before cooling.
Can the FlexCut 125 be used for welding?
No, the FlexCut 125 is a plasma cutter only. It is not designed for welding. For welding, consider Lincoln Electric's welding machines.
What safety precautions should I take when using the FlexCut 125?
Always wear welding helmet with shade 5-8, gloves, and flame-resistant clothing. Ensure proper ventilation to avoid fumes. Disconnect power before servicing.
How often should I perform maintenance on my FlexCut 125?
Check consumables daily for wear. Replace as needed. Clean the air filter monthly. Inspect cables and torch for damage before each use.
What does error code E-01 mean on the FlexCut 125?
Error E-01 usually indicates input voltage too low. Check that the power cord is plugged into a proper outlet and the voltage is within range (90-135 V for 120 V, 180-265 V for 240 V).
Where can I buy spare parts for the FlexCut 125?
Genuine Lincoln Electric consumables and parts are available through authorized distributors and the Lincoln Electric online store. Use part numbers from the manual.

User questions about FlexCut 125 LINCOLN ELECTRIC

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Welding machine in PDF format for free! Find your manual FlexCut 125 - LINCOLN ELECTRIC and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. FlexCut 125 by LINCOLN ELECTRIC.

USER MANUAL FlexCut 125 LINCOLN ELECTRIC

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : LINCOLN ELECTRIC

Model : FlexCut 125

Category : Welding machine