Product Type Oxygen Meter
Model Oxy 3690 MP
Brand Greisinger
Measurement Range 0.0 to 100.0% O2
Resolution 0.1% O2
Accuracy ±0.2% O2 (at 20°C)
Display LCD, 4-digit
Power Supply 9V battery (6LR61)
Battery Life Approx. 200 hours continuous use
Dimensions 142 × 71 × 26 mm
Weight 235 g (with battery)
Operating Temperature 0 to 50°C
Storage Temperature -20 to 60°C
Sensor Type Electrochemical cell
Key Functions Hold, Min/Max, Auto-off, Calibration
Calibration Manual calibration in fresh air (20.9% O2)
Maintenance Periodic sensor replacement; clean housing with damp cloth
Safety CE compliant; not for medical use
Accessories Included Battery, protective cap, manual
Spare Parts Availability Sensor and battery available from Greisinger service

Frequently Asked Questions - Oxy 3690 MP Greisinger

How do I calibrate the Oxy 3690 MP?
To calibrate, turn on the device and hold it in fresh, clean air (20.9% O2). Press the CAL button until the display shows 'CAL' and the value stabilizes. The device automatically adjusts to 20.9%.
What type of battery does the device use?
It uses a standard 9V battery (6LR61). For best performance, use alkaline batteries.
How often should I replace the oxygen sensor?
The electrochemical sensor typically lasts 1-2 years depending on usage and storage conditions. Replace it when calibration fails or readings become unstable.
Can I measure oxygen in liquids?
No, the Oxy 3690 MP is designed for gaseous oxygen measurement in air. Do not immerse the sensor in liquids.
What does the 'Hold' function do?
The Hold function freezes the current reading on the display. Press HOLD to capture a value; press again to release.
Why does the device show inaccurate readings?
Common causes: sensor expired, low battery, need for calibration, or exposure to extreme temperatures. Check battery, recalibrate, and if still inaccurate, replace the sensor.
Is the device suitable for medical use?
No, the Oxy 3690 MP is a general-purpose measuring instrument and is not certified for medical applications. For medical oxygen monitoring, use a dedicated medical device.
How do I clean the device?
Use a soft, damp cloth to clean the housing. Do not use solvents or abrasive cleaners. Avoid moisture entering the sensor area.
What is the auto-off feature?
To conserve battery, the device automatically turns off after 10 minutes of inactivity. Press any button to wake it.
Where can I purchase replacement sensors?
Replacement sensors can be ordered from Greisinger or authorized distributors. Use only genuine Greisinger sensors for accurate measurements.

User questions about Oxy 3690 MP Greisinger

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Measuring equipment in PDF format for free! Find your manual Oxy 3690 MP - Greisinger and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. Oxy 3690 MP by Greisinger.

USER MANUAL Oxy 3690 MP Greisinger

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Greisinger

Model : Oxy 3690 MP

Category : Measuring equipment