Notice Sonel MZC-310S - page 6
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Low voltage network parameters meter
Brand Sonel
Model MZC-310S
Dimensions (approx.) 220 x 100 x 50 mm
Weight (approx.) 0.5 kg
Power Supply 4 x AA batteries
Main Functions Resistance (R) measurement, short-circuit loop impedance (Z) measurement, prospective fault current (Ipk) measurement, voltage measurement
Measurement Ranges Resistance: 0.00 Ω to 199.9 Ω; Impedance: 0.00 Ω to 199.9 Ω; Voltage: 0 V to 500 V AC
Accuracy ±(2% + 3 digits) for resistance and impedance
Display LCD, 3½ digits
Overvoltage Category CAT III 300 V
Protection Rating IP40
Operating Temperature 0 °C to 40 °C
Storage Temperature -20 °C to 60 °C
Standards Compliance IEC 61557, IEC 61010
Safety Double insulation, automatic discharge of tested object
Maintenance and Cleaning Wipe with a dry cloth; do not use solvents. Calibration recommended every 12 months.
Spare Parts and Repairability Replaceable test leads, fuses; service by authorized Sonel service center
General Information Portable, handheld device with auto-ranging, data hold function

Frequently Asked Questions - MZC-310S Sonel

How do I measure loop impedance with the MZC-310S?
Connect the test leads to the L and PE terminals. Select the Z function. Press the test button. The device will display the impedance value. Ensure the circuit is de-energized before connecting.
What batteries does the MZC-310S use?
The device uses 4 AA alkaline batteries. Replace them when the low battery indicator appears.
Can I measure voltage with this device?
Yes, the MZC-310S can measure AC voltage up to 500 V. Select the V function and connect the test leads to L and N terminals.
What is the accuracy of resistance measurements?
The accuracy for resistance is ±(2% of reading + 3 digits) for the range 0.00 Ω to 199.9 Ω.
How do I clean the device?
Use a dry, soft cloth to clean the casing. Do not use any solvents or abrasive cleaners.
What safety precautions should I follow?
Always adhere to CAT III 300 V safety ratings. Ensure the circuit is de-energized before connecting. Do not use if the device is damaged.
How often should the device be calibrated?
Sonel recommends calibration every 12 months to maintain accuracy. Contact an authorized service center.
What is the IP rating of the MZC-310S?
The device has an IP40 rating, meaning it is protected against solids larger than 1 mm but not against water.
Does the device have a data hold function?
Yes, press the HOLD button to freeze the current reading on the display. Press again to release.
Can I replace the test leads?
Yes, the test leads are replaceable. Use only Sonel approved leads to ensure safety and accuracy.

User questions about MZC-310S Sonel

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Measuring equipment in PDF format for free! Find your manual MZC-310S - Sonel and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. MZC-310S by Sonel.

USER MANUAL MZC-310S Sonel

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Sonel

Model : MZC-310S

Category : Measuring equipment