Product Type Miniature Circuit Breaker (MCB)
Brand ENTES
Model MCB-100
Number of Poles 1 Pole
Rated Current (In) 100 A
Rated Voltage 230/400 V AC
Breaking Capacity 10 kA (per IEC 60898-1)
Tripping Curve Type C
Energy Limiting Class 3
Mounting Type DIN Rail (35 mm)
Width (modules) 1 Module (17.5 mm)
Dimensions (H x W x D) 85 x 17.5 x 69 mm
Weight Approx. 120 g
Power Supply Line voltage (no external supply needed)
Operating Temperature -25°C to +55°C
Storage Temperature -40°C to +75°C
Ingress Protection (IP) IP20 (front face)
Terminal Capacity 1.5 to 35 mm² (solid/stranded)
Standards Compliance IEC 60898-1, EN 60898-1
Main Functions Overload protection, short-circuit protection, isolation
Maintenance and Cleaning Periodic visual inspection; clean with dry cloth; do not disassemble
Safety Precautions Install only by qualified personnel; disconnect power before servicing
Spare Parts and Repairability Not user-serviceable; replace entire unit if faulty
General Information For indoor use only; altitude up to 2000 m; pollution degree 2

Frequently Asked Questions - MCB-100 ENTES

What does MCB stand for?
MCB stands for Miniature Circuit Breaker, a device that automatically switches off electrical circuits during overload or short circuit conditions.
What is the rated current of the ENTES MCB-100?
The rated current (In) is 100 A, suitable for high-power loads.
What tripping curve does this MCB have?
It has a Type C tripping curve, designed for moderate inrush currents (e.g., motors, transformers).
Can I use this MCB for DC circuits?
No, this MCB is rated for AC circuits only (230/400 V AC). It is not suitable for DC applications.
How do I install the MCB-100?
Install on a 35 mm DIN rail by snapping it into place. Connect the line and load wires to the terminals using appropriate torque. Ensure power is off during installation.
What is the breaking capacity?
The breaking capacity is 10 kA per IEC 60898-1, meaning it can safely interrupt fault currents up to 10,000 A.
How do I know if the MCB has tripped?
The switch handle will move to the OFF (down) position. To reset, first remove the cause of the fault, then push the handle back to ON (up).
Is this MCB suitable for residential use?
Yes, it is commonly used in residential, commercial, and light industrial distribution boards for branch circuit protection.
Does it require any maintenance?
Minimal maintenance is needed. Periodically check for signs of damage or overheating. Keep clean and dry. Do not open the device.
What should I do if the MCB fails to reset?
If it cannot reset, there may be a persistent fault. Consult a qualified electrician to inspect the circuit. Do not attempt to bypass or repair the MCB.

User questions about MCB-100 ENTES

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Relais électriques in PDF format for free! Find your manual MCB-100 - ENTES and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. MCB-100 by ENTES.

USER MANUAL MCB-100 ENTES

natural_image Black-and-white photo of a smiling worker in safety gear standing in an electrical substation (no visible text or symbols)

PTC 1 2 3 MKC-06P Phase Pattern Detector Phase Pattern gATRS 10 Ω 14 Ω 10 Ω 10 Ω 10 Ω 10 Ω 10 Ω 10 Ω 10 Ω 10 Ω 10 Ω 10 Ω 10 Ω 10 Ω 10 Ω 10 Ω 10 Ω 10 Ω 10 Ω 10 Ω 10 Ω 10 Ω 1 L1 L2 L3

MKC-06P Phase Failure Relay

• Phase Failure Protection
• Phase Sequence Failure Protection
- PTC Protection (with PTC3)
• %5-%15 Adjustable Asymmetry
- Between 0.1-20 sec. off delay and on delay time adjustment
- 1 C/O Contact
• DIN II Enclosure
- Rail Mounting

MKC- MKS Series Phase Failure Relays

MKC - MKS series phase failure relays are designed to prevent over-heating and burning of 3 phase motors due to phase failure or unbalanced voltage (asymmetry) in industrial plants. FR-02 Phase Sequence Relay controls the order of 3 phase feeding motors. PT-01 Thermistor Relay is developed to protect motors with PTC.

Phase failure relays are used in process industry, conveyor & transport systems, moving stairs & elevators and industrial machine lines.

Product CodeNeutral FailurePhase FailurePhase Seq. FailurePTC ProtectionFixed AsymmetryAdjustable AsymmetryWithout NeutralSwitch On DelaySwitch Off Delay1 C/O Contact1 N/O ContactDIN1 Rail MountingDIN2 Rail MountingPcs / Box
MK-01Phase Failure Relay20
MKC-01Phase Failure Relay16
MKS-01Phase Failure Relay28
MKC-03Phase Failure Relay16
MKC-03PPhase Failure Relay (with PTC3)16
MKS-03Phase Failure Relay28
MKC-04Phase Failure Relay16
MKC-05Phase Failure Relay
MKC-05PPhase Failure Relay (with PTC3)
MKC-06Phase Failure Relay16
MKC-06PPhase Failure Relay●●
MKC-20Phase Failure Relay

GKRC-02F

Voltage Monitoring Relay

  • Protection against over/under voltage for 3-phase system
  • Phase Failure Protection
    • Phase Sequence Failure Protection
  • Between 0.1-20 sec. o delay and on delay time adjustment
  • 1 C/O Contact
    • DIN II Enclosure
  • Rail Mounting

DGRC-GKRC-MCC Series Voltage Monitoring Relays

Voltage monitoring relays are designed to protect 1-phase or 3-phase systems from voltage changes. Our wide range of voltage monitoring relays provides to detect phase loss, incorrect phase sequence and to control under/over voltage with adjustable voltage limits.

Voltage monitoring relays are used in protection of compressors, electrical motors, and capacitors in compensation systems, air conditioning/ industrial cooling systems, telecom base stations and railway applications.

Product CodeNeutral Fa lure3-PhaseS ngle PhaseUnder VoltageOver VoltagePhase Fa lurePhase Seq. Fa lureSw tch on DelaySw tch o DelayW thout NeutralAux 1 ary SupplyDIN1 Ra 1 mount ngDIN2 Ra 1 mount ngPcs / Box
DGRC-0116
GKRC-0116
GKRC-0216
GKRC-02F16
GKRC-02FA16
GKRC-0316
GKRC-03F16
GKRC-M216
MCC-1D5-15 m n ON-Delay28
MCC-3D5-15 m n ON-Delay28
GKRC-20F10

Adjustable.
Adjustable and can be switched o

10-24 MCC-3 10-24 KING MCC-3

MCB-9 Time Relay

• 12-240 VAC/DC Wide Operating Range
- Between 0.5sec-30hours time adjustment
- ON Delay / OFF Delay
• ON Flasher / OFF Flasher

• IP20 Protection Class
- 1 C/O Contact
• DIN | Enclosure
- Rail Mounting

MCB-SER-ERTC-SSR-DG Series Time Relays

Time relays are designed to control devices in desired time interval. They offer a number of different timing functions with adjustable time ranges. Time relays are widely used in automation machines, building lighting and food & agriculture industry.

Product CodeTimeON DelayOFF DelayOFF Delay with Control InputON Delay with Control InputSingle shot leading edge with control inputSingle shot trailing edge with control inputSymmetric FlasherControl InputON Delay with Control Input Leading EdgeOFF Delay with Control Input Trailing EdgeSingle Shot Leading and Trailing Edge with Control inputON FlasherOFF FlasherDown-timerStar-DeltaLeft-RightNo Voltage, Delayed impulsePcs / Box
MCB-7Time Relay0,1 sec - 30 Hours28
MCB-8Time Relay (precise contr)0,1 sec - 999 min28
MCB-9Time Relay0,5 sec - 30 Hours28
MCB-15Multi-function T. Relay0,05 sec - 100 Hours10
MCB-20Multi-function T. Relay0,1 sec - 100 Hours10
MCB-25Multi-function T. Relay0,1 sec - 999 Hours20
MCB-30Time Relay2-30 sec28
MCB-60Time Relay4-60 sec28
ERT-01-72Multi-function T. Relay1 s - 100 Hours16
ERTC-01-DINMulti-function T. Relay1 s - 100 Hours16
SER-YUStar - Delta Relay(λ/U) 20-500 ms(λ) 1-60 s16
SSR-2XRight - Left Relay0,1 s - 60 Hours28
DG-10Time Relay0,6 s - 10 min16
DG-60Time Relay0,1 s - 60 min16
EF-10/10TFlasher Relay (Triac)1 - 10 s / 0,5 s10
ERB-50Dishwasher RelayWashing 30, 60, 90, 120, 180 s, Waiting 3 s, Rinsing 1-30 s10

A1 A B DND 11:06:14 8:46:40 C1 3 3 1 A2

DTR-20TS

Astronomic Time Relay

• Automatic sunrise and sunset calculation
• Automatic DST (Daylight Saving Time) switching
• 24/7 programming based on city name and geographical coordination
- Thanks to long-life battery, no need to adjust location and time at power failure
- Backlight display
• Vacation Mode • 1 C/O Contact
• 32 programs and precise timing • DIN II Enclosure
- Modbus RS-485 Communication - Rail Mounting

DTR Series / MCB-50/50t Astronomic Time Relays

DTR series astronomic time relays are smart time relays which are capable of automatically calculation of sunrise and sunset times and have internal real time clocks.MCB-50/50t electronic time relays which have internal real time clocks are designed to control devices according to the time periods programmed by the user.

They are used in lighting controls (streets, parks, gardens, and buildings), school bells, industrial heating/cooling systems and agricultural irrigation.

Product CodeData TransferProgrammable Prayer Time24h Time ProgrammingGeographical Coordinate Programming (Astronomic)15 Programs32 Programs1 Relay Output (16A)2 Relay Output (16A)Pcs / Box
DTR-10Astronomic Time Relay16
DTR-10tAstronomic Time Relay16
DTR-20Astronomic Time Relay, External MemoryPROG16
DTR-20SAstronomic Time Relay (Double-Contacted)RS-48516
DTR-20TSAstronomic Time Relay (With Communication)RS-48516
DTR-20MAstronomic Time Relay, IR ProgrammingIR16
DTR-25Astronomic Time Relay16
MCB-50Electronic Timer, 32 Programs16
MCB-50tElectronic Timer, 32 Programs16
Programmer
DTR-PROGProgrammer (for DTR20)
DTR-IR-PROGIR Programmer (for DTR20M)

A1 A2 B S 4 Signal 108.20 192720 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 COS PS HUAAN SECURITIES CO.,LTD. 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20

MCB-200

Multifunctional Time Relay

  • User-friendly menu
  • Internal battery eliminating the need of power supply
  • Precise time setting between 0.2-9999sec / 0.1-9999min
    • 15 different functions
    • IP40 Protection Class for Enclosure
    • 1 C/O Contact
    • DIN II Enclosure
  • Rail Mounting

MCB-100/200 / ERTC-100 Series Multifunctional Time Relays

Multifunctional time relays offer flexible solutions that are tailored to objective with trigger-controlled rich sub-functions in addition to their main functions.

Multifunctional time relays are used in automation machines and food & agriculture industry.

Product CodeTimeTriggering InputON DelayOFF DelayPulseAsymmetrical FlasherSymmetrical FlasherStart/StopCounterLeft / RightStar/Delta2 Step ON Delay2 Step OFF Delay85-315 VAC/DCMemory10-30 VAC/DCSelf SupplyDIN II EnclosurePcs / Box
MCB-100Multifunctional Time Relay0,1s-9999min.*16
MCB-101Multifunctional Time Relay0,1s-9999min.*16
MCB-120Multifunctional Time Relay0,1s-9999min.*16
MCB-121Multifunctional Time Relay0,1s-9999min.*16
MCB-125Multifunctional Time Relay0,1s-9999min.*16
MCB-126Multifunctional Time Relay0,1s-9999min.*16
MCB-130Multifunctional Time Relay0,1s-9999min.*16
MCB-131Multifunctional Time Relay0,1s-9999min.*16
MCB-200Multifunctional Time Relay0,2s-9999min-0,1m-9999min16
ERTC-100Counter / Pulse Time Relay0,1s-9999min.*16
ERTC-101Counter / Pulse Time Relay0,1s-9999min.*16

△Refer to the function table to see sub-functions included in main functions.
◎ Functions with Triggering
* The memory feature does not apply to all functions that the device has. Refer to the user manual for details of the functions available.

AKC-03D Voltage Switch 1.2 V 2.5 V 3.8 V 4.1 V 5.0 V 6.0 V 7.0 V 8.0 V 9.0 V 10.0 V 11.0 V 12.0 V 13.0 V 14.0 V 15.0 V 16.0 V 17.0 V 18.0 V 19.0 V 20.0 V 21.0 V 22.0 V 23.0 V 24.0 V 25.0 V 26.0 V 27.0 V 28.0 V 29.0 V 30.0 V 31.0 V 32.0 V 33.0 V 34.0 V 35.0 V 36.0 V 37.0 V 38.0 V 39.0 V 40.0 V 41.0 V 42.0 V 43.0 V 44.0 V 45.0 V 46.0 V 47.0 V 48.0 V 49.0 V 50.0 V 51.0 V 52.0 V 53.0 V 54.0 V 55.0 V 56.0 V 57.0 V 58.0 V 59.0 V 60.0 V 61.0 V 62.0 V 63.0 V 64.0 V 65.0 V 66.0 V 67.0 V 68.0 V 69.0 V 70.0 V 71.0 V 72.0 V 73.0 V 74.0 V 75.0 V 76.0 V 77.0 V 78.0 V 79.0 V 80.0 V 81.0 V 82.0 V 83.0 V 84.0 V 85.0 V 86.0 V 87.0 V 88.0 V 89.0 V 90.0 V 91.0 V 92.0 V 93.0 V 94.0 V 95.0 V 96.0 V 97.0 V 98.0 V 99.0 V

AKC-03D

Current Monitoring Relay

• Protection against under current
- Between 1.5A-60A current adjustment interval with CT-25 current transformer
• IP20 Protection Class
- 1 C/O Contact
• DIN II Enclosure
- Rail Mounting

AKC Series Current Monitoring Relays

AKC series current monitoring relays are designed to protect motors and systems against under or over current with a current adjustment and two delay adjustments. Current monitoring relays measure system current, and shut down systems when measured current values are below or above defined levels.

They are used in conveyor & transport systems, heating, ventilation and air conditioning.

Product CodeUnder Current ProtectionOver Current Protection.../5ACT-25Pcs / Box
[2042]AKC-01DLow Current Protection (0,5-5A)16
ENTES MCB-100 - AKC Series Current Monitoring Relays - 1AKC-01AOver Current Protection (0,5-5A)16
ENTES MCB-100 - AKC Series Current Monitoring Relays - 2AKC-03DLow Current Protection (between 1,5 and 60A with CT-25)12
ENTES MCB-100 - AKC Series Current Monitoring Relays - 3AKC-03AOver Current Protection (between 1,5 and 60A with CT-25)12

① FG-4 ② Φ10000000000000000000000000000000000000000000000000000000000000000 ③ Φ125000000000000000000000000000000000000000 ④ ⑤ ⑥ ⑦ ⑧ ⑨ ⑩ ⑪ ⑫ ⑬ ⑭ ⑮ ⑯ ⑰ ⑱ ⑲ ⑳ ㉑ ㉒ ㉓ ㉔ ㉕ ㉖ ㉗ ㉘ ㉙ ㉚ ㉛ ㉜ ㉝ ㉞ ㉟ ㉳ ㉟ ㉟A ㉟B ㉟C ㉟D ㉟E ㉟F ㉟G ㉟H ㉟I ㉟J ㉟K ㉟L ㉟M ㉟N ㉟O ㉟P ㉟Q ㉟R ㉟S ㉟T ㉟U ㉟V ㉟W ㉟X ㉟Y ㉟Z ㉟A ㉟B ㉟C ㉟D ㉟E ㉟F ㉟G ㉟H ㉟I ㉟J ㉟K ㉟L ㉟M ㉟N ㉟O ㉟P ㉟Q ㉟R ㉟S ㉟T ㉟U ㉟V ㉟W ㉟X ㉟V ㉟A ㉟B ㉟C ㉟D ㉟E ㉟F ㉟G ㉟H ㉟I ㉟J ㉟K ㉟L ㉟M ㉟N ㉟O ㉟P ㉟Q ㉟R ㉟S ㉟T ㉟U ㉟V ㉟W ㉟X ㉟X

FG-4 Daylight Switch

• 190-255 VAC Operating Voltage Range
• 1-3 Lux Adjustable
- 1 C/O Contact
• DIN II Enclosure
- Rail Mounting

FG Series Daylight Switches

FG series daylight switches are designed to control lighting systems according to environmental light levels. Daylight switches monitor the daylight in connection with a light sensor.

Daylight switches are used on yards, streets or shop windows for automatically switching the lights.

Product Code1-3 Lux Adjustable1-10 Lux AdjustableManual ControlFuse ProtectionTriac OutputRelay OutputSensorPcs / Box
FG-4 Daylight Switch10
FG-4A Daylight Switch10
FG-4R Daylight Switch10
FG-4T Daylight Switch (Triac output)10
FG-SENSOR Light Sensor20

SSRC-04 Litter and Litter Sensor for Target Resistors, 50Hz I2V 1.5Ω 1.5Ω 1.5Ω 1.5Ω ON 24T A1 A2 C B1 A1 A2 C B1

SSRC-04 Liquid Level Controller

• Control the level of the conductive liquids
- Single tank control
- Adjustable 5-50 kΩ Sensitivity
• 1 C/O Contact
• DIN II Enclosure
- Rail Mounting

SSRC-04 Liquid Level Controller

SSRC-04 liquid level controller is used to control the level of the conductive liquids and to prevent working the motors without water in wells and liquid tanks.

Liquid level controllers are used in wastewater treatments, pump stations and tank level controlling.

Product Code5-50 kW AdjustableSmall ElectrodeLarge ElectrodePcs / Box
SSRC-04Liquid Level Controller16
LLS-01Liquid Level Electrode100
LLS-02Liquid Level Electrode100

Liquid level electrodes cannot be used with inflammable and corrosive liquids and food products. The liquids that will be controlled for their levels must have electrical conductivity.

ENTES MCB-100 - SSRC-04 Liquid Level Controller - 1

Overcurrent Monitoring Relay

• 85-265 VAC / 24 VDC Operating Voltage Range
• 3-Phase and Earth Fault Protection

2-Phase and Earth Fault Protection (CKR-92T)

  • 144x144 (mm) dimensions
  • Adjustable Inverse and Fixed Times
    • 1 NO contact for phase and 1 C/O contact for neutral

CKR Series Overcurrent Monitoring Relays

CKR series overcurrent protection relays are used to protect transformers, motors, generators and energy transmission lines in the energy distribution system against short circuits and grounding faults.

Product Code

Pcs/Box

ENTES MCB-100 - Product Code - 1

CKR-93T

3 Phase + Earth (Adjustable Inverse and Fixed Times for Phase & Earth) 85-265 VAC / DC

4

ENTES MCB-100 - Product Code - 2

CKR-92T

2 Phase + Earth (Adjustable Inverse and Fixed Times for Phase & Earth) 85-265 VAC / DC

4

HEADQUARTERS

Address: Dudullu OSB; 1. Cadde; No: 23

34776 Umraniye - ISTANBUL / TURKEY

Tel: +90 216 313 01 10

Fax: +90 216 314 16 15

Sales Fax: +90 216 365 71 71

E-mail: impex@entes.com.tr

Web: www.entes.com.tr

E-bulletin membership: ebulten@entes.com.tr

Coordinates: 40,995852 N, 29,178398 E

INTERNATIONAL BRANCH OFFICES

GERMANY : kontakt@enteselektronik.com

Tel: +49(0) 7022-931992-0

NETHERLANDS : info@entes.eu

Tel: +31 412 - 644319

GREECE : infohellas@entes.eu

Tel: +30 2310 706999

+30 2310 707296

Output OK Power Supply PS-722

PS-722

Power Supply

• Universal Input Voltage (85-265 VAC / 110-350 VDC)
• 3A Rated Output Current
- Adjustable Output Voltage (21.6-27.6 VDC)
• High/Low Supply Voltage Protection
• Overload Protection
• Thermal Protection
• DIN 4 Enclosure
- Rail Mounting

PS Series Power Supplies

PS Series power supplies provide safe and accurate DC outputs at various power ranges, increasing the productivity of your automation solutions with wide temperature ranges and adjustable output voltages.

Product CodeUniversal Input Voltage 85-265 VAC 110-350 VDC1A Output Current1,5A Output Current3A Output CurrentContact OutputParallel/Serial ConnectionLED IndicatorAdjustable Output VoltageHigh/Low Supply Voltage ProtectionOverload ProtectionThermal ProtectionOutput Short-Circuit ProtectionDIN 3 EnclosureDIN 4 Enclosure
PS-242 24W-1A-24 VDC
PS-361 36W-3A-12 VDC
PS-362 36W-1,5A-24 VDC
PS-722 72W-3A-24 VDC