| Product Type | Swimming Pool Pump |
| Brand | AstralPool |
| Model | CTX 360 |
| Dimensions (L x W x H) | Approx. 600 x 250 x 350 mm |
| Weight | Approx. 15 kg |
| Power Supply | 230 V / 50 Hz, single phase |
| Motor Power | 1.5 HP (1.1 kW) |
| Flow Rate | Up to 12 m³/h at 10 m head |
| Maximum Head | 15 m |
| Suction Connection | 1 1/2" (DN40) female thread |
| Discharge Connection | 1 1/2" (DN40) female thread |
| Pre-Filter Volume | 2.5 L |
| Self-Priming | Yes, up to 2 m |
| Protection Class | IPX5 |
| Insulation Class | F |
| Noise Level | < 70 dB(A) |
| Operating Temperature | 5°C - 40°C |
| Functions | Water circulation, filtration, heating support |
| Maintenance | Clean pre-filter basket weekly; check seals annually |
| Safety Features | Thermal overload protection, IPX5 water resistance |
| Spare Parts Availability | Mechanical seal, impeller, O-rings, pre-filter basket |
| Repairability Index | 7/10 (common parts available) |
| Warranty | 2 years (manufacturer) |
| Included Accessories | Installation manual, O-rings, connection adapters |
Frequently Asked Questions - CTX 360 ASTRALPOOL
How do I prime the CTX 360 pump?
Ensure the pump is filled with water before starting. Open the pre-filter lid, fill the basket with water, then close tightly. Start the pump; it should self-prime up to 2 m. If not, check for air leaks.
What is the recommended maintenance schedule?
Clean the pre-filter basket weekly during peak season. Inspect mechanical seal and O-rings annually. Lubricate O-rings with silicone grease if needed.
Can the pump run dry?
No, running dry can damage the mechanical seal and motor. Always ensure water supply before operation. The pump has thermal protection but avoid dry running.
What type of lubricant should I use for O-rings?
Use silicone-based lubricant only. Petroleum-based products can damage the O-rings.
How do I replace the mechanical seal?
Disconnect power, drain pump, remove motor and impeller. Replace the seal assembly (rotating and stationary parts). Reassemble and check for leaks. See manual for torque specs.
Why is the pump making a loud noise?
Possible causes: cavitation (low water level), air in system, worn bearings, or debris in impeller. Check water level, bleed air, and inspect impeller.
What are the electrical requirements?
The pump requires 230 V / 50 Hz single-phase supply, connected via a 10 A circuit breaker. Ensure proper grounding.
Can I use the pump for saltwater pools?
Yes, the CTX 360 is compatible with saltwater (up to 5 g/L). However, rinse the pump with fresh water after winterization to prevent corrosion.
How do I winterize the pump?
Drain all water from pump, remove drain plugs, store in a dry frost-free area. Clean filter basket and seal. Cover intake and discharge openings.
What is the maximum operating pressure?
The maximum working pressure is 2.5 bar (36 psi). Do not exceed this to avoid damage.