Owon

SDS200 - Measuring equipment Owon - Free user manual and instructions

Find the device manual for free SDS200 Owon in PDF.

📄 74 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Owon SDS200 - page 1
Pick your language and provide your email: we'll send you a specifically translated version.
Product TypeDigital Storage Oscilloscope
Bandwidth200 MHz
Sample Rate (Real-Time)1 GSa/s
Channels2
Display7-inch TFT LCD, 800x480 pixels
Vertical Resolution8 bits
Input Impedance1 MΩ ±2% // 15 pF ±3 pF
Timebase Range2 ns/div to 100 s/div
Trigger TypesEdge, Pulse, Video, Slope
Math Functions+, -, ×, ÷, FFT
Dimensions (W×H×D)320 × 150 × 120 mm
Weight2.5 kg
Power SupplyAC 100-240 V, 50/60 Hz
Power Consumption30 W (max)
StorageUSB host for waveform storage
ConnectivityUSB Device, USB Host, LAN (optional)
Safety ComplianceEN 61010-1, CAT I 300V
CleaningWipe with dry cloth; no solvents
Spare Parts / RepairContact Owon service center
Warranty3 years

Frequently Asked Questions - SDS200 Owon

How do I calibrate the SDS200?
Access the calibration menu via Utility > Calibration. Ensure the device is warmed up for 30 minutes and no signal is applied.
What probes are compatible with the SDS200?
Standard BNC probes with 1x/10x attenuation are compatible. The input impedance is 1 MΩ, so use 10x probes for high-frequency signals.
Can I use the SDS200 to measure AC mains voltage?
No, the SDS200 is rated for CAT I 300V only. Do not connect directly to mains. Use a differential probe if necessary.
How do I save waveforms to a USB drive?
Insert a USB drive, press Save, choose Waveform format, and select the destination. The device supports FAT32 formatted drives.
What is the maximum input voltage?
The maximum input voltage is 300 V peak (CAT I) when using a 10x probe. Direct input limit is 40 V peak.
How do I update the firmware?
Download the latest firmware from Owon's website, copy to a USB drive, go to Utility > Update Firmware, and follow on-screen instructions.
Why is the waveform noisy?
Check probe ground connection, ensure proper shielding, and use bandwidth limit (20 MHz) via Channel menu to reduce high-frequency noise.
How do I perform an FFT analysis?
Press Math, select FFT, choose source channel, and set vertical scale and position. Use time/div to adjust frequency resolution.
What does the 'Auto Set' button do?
The Auto Set button automatically adjusts vertical, horizontal, and trigger settings to display a stable waveform for the input signal.
How do I measure frequency or period?
Press Measure, select Frequency or Period, and choose the source channel. The measurement is displayed at the bottom of the screen.

User questions about SDS200 Owon

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Measuring equipment in PDF format for free! Find your manual SDS200 - Owon and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. SDS200 by Owon.

USER MANUAL SDS200 Owon

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Owon

Model : SDS200

Category : Measuring equipment