OLS2000ECXL - Inverter CyberPower - Free user manual and instructions
Find the device manual for free OLS2000ECXL CyberPower in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Product Type | Online Double-Conversion UPS |
| Model | OLS2000ECXL |
| Brand | CyberPower |
| Power Capacity | 2000 VA / 1800 W |
| Input Voltage | 220-240 VAC |
| Output Voltage | 220-240 VAC (regulated) |
| Frequency | 50/60 Hz (auto-sensing) |
| Waveform | Pure Sine Wave |
| Battery Type | Sealed Lead-Acid (maintenance-free) |
| Battery Quantity | 2 x 12V/9Ah (internal) |
| Typical Runtime (half load) | Approx. 20-30 minutes |
| Outlets | 8 x IEC 320 C13 (battery & surge), 1 x IEC 320 C19 (battery & surge) |
| Surge Protection | Yes (Joules rating not specified) |
| Management | USB, RS-232, SNMP slot (optional card) |
| Display | LCD panel with status indicators |
| Dimensions (W x H x D) | 17.2 x 3.5 x 17.5 in (437 x 89 x 445 mm) |
| Weight | Approx. 45 lbs (20.4 kg) |
| Form Factor | Rackmount/Tower convertible (2U) |
| Cooling Fan | Variable speed, temperature-controlled |
| Operating Temperature | 32-104°F (0-40°C) |
| Safety Certifications | UL 1778, CSA, FCC Class A |
| Maintenance | Periodic battery check and replacement every 3-5 years |
Frequently Asked Questions - OLS2000ECXL CyberPower
What is the typical runtime of the OLS2000ECXL at half load?
The typical runtime at half load (900W) is approximately 20-30 minutes, depending on battery age and condition.
How do I replace the batteries in the OLS2000ECXL?
The unit uses internal sealed lead-acid batteries. To replace, disconnect from mains, open the front panel, remove the battery tray, disconnect and replace batteries (2 x 12V/9Ah). Observe polarity and recycle old batteries properly.
Can the OLS2000ECXL be mounted in a rack?
Yes, it is a 2U rackmount/tower convertible form factor. Rackmount brackets and ear are included.
Does this UPS provide pure sine wave output?
Yes, the OLS2000ECXL produces a pure sine wave output, making it suitable for sensitive electronics.
What management interfaces are available?
It has USB and RS-232 ports, plus an expansion slot for an optional SNMP/network management card.
How often should I test the UPS?
It is recommended to perform a self-test monthly to ensure proper operation. The UPS can also be configured for automatic self-tests.
Can I connect a generator to the OLS2000ECXL?
Yes, but ensure the generator output is stable and within the input voltage range (220-240V). The UPS may switch between utility and generator power.
What type of output receptacles are included?
It includes 8x IEC C13 and 1x IEC C19 outlets, all providing battery backup and surge protection.
Is the OLS2000ECXL compatible with external battery packs?
Yes, it supports the BP48 series battery packs for extended runtime (sold separately).
What does the LCD display show?
The LCD shows input/output voltage, load level, battery capacity, and status alerts (e.g., on battery, overload, low battery).
User questions about OLS2000ECXL CyberPower
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.
Download the instructions for your Inverter in PDF format for free! Find your manual OLS2000ECXL - CyberPower and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. OLS2000ECXL by CyberPower.