Notice Minuteman EN350 - page 3
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Uninterruptible Power Supply (UPS)
Model EN350
Brand Minuteman
Power Capacity 350 VA / 210 W
Input Voltage 120 VAC
Output Voltage 120 VAC (simulated sine wave)
Number of Outlets 4 (battery backup + surge protection)
Battery Type Sealed lead-acid, maintenance-free
Typical Backup Time 10-15 minutes at full load
Recharge Time 6-8 hours
Dimensions (W x D x H) 6.5 x 10.5 x 3.5 inches
Weight 7.5 lbs (3.4 kg)
Input Plug NEMA 5-15P
Output Receptacles NEMA 5-15R
Surge Protection Yes, 240 joules
Noise Filtering Yes, EMI/RFI filtering
Cooling Fan (variable speed)
Audible Alarms On battery, low battery, overload
Interface USB (optional)
Operating Temperature 32°F to 104°F (0°C to 40°C)
Relative Humidity 0% to 95% (non-condensing)
Safety Approvals UL, cUL, FCC Class B
Maintenance Battery replacement every 2-3 years

Frequently Asked Questions - EN350 Minuteman

How do I connect devices to the EN350 UPS?
Plug your devices into the battery backup outlets (marked with a battery icon). The remaining outlets provide surge protection only. Ensure total load does not exceed 210W.
What is the typical backup time for this UPS?
At full load (210W), the EN350 provides approximately 10-15 minutes of backup. At half load, runtime extends to 20-30 minutes.
How long does it take to fully recharge the battery?
After a full discharge, the battery recharges completely in about 6-8 hours.
What does the audible alarm mean?
A beep every few seconds indicates the UPS is on battery. A rapid beep signals low battery. Continuous beeping indicates an overload or fault.
Can I replace the battery myself?
Yes, the battery is user-replaceable. Open the front panel, disconnect the terminals, and replace with a standard 12V 7Ah battery. Please recycle the old battery.
Is the EN350 compatible with generators?
It is not recommended to connect the UPS directly to a generator. Use a generator with stable output and allow it to run for a few minutes before connecting the UPS.
What should I do if the UPS does not turn on?
Check that the UPS is plugged into a working wall outlet and the power switch is on. If still off, try a different outlet. If no response, the battery may be dead.
How often should I test the UPS?
Perform a self-test every 3 months by unplugging the UPS from AC power while loads are connected. Verify that devices continue running and alarms sound.
Can I plug a power strip into the UPS?
No, do not plug power strips into the UPS. Connect devices directly to the UPS outlets to avoid overloading and reduce fire risk.
What is the warranty period?
Minuteman typically offers a 2-year warranty on the UPS and a 2-year warranty on connected equipment. Check your specific model confirmation.

User questions about EN350 Minuteman

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Alimentation sans coupure in PDF format for free! Find your manual EN350 - Minuteman and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. EN350 by Minuteman.

USER MANUAL EN350 Minuteman

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Minuteman

Model : EN350

Category : Alimentation sans coupure