Orima ORT-09-R32 - Air Conditioning

ORT-09-R32 - Air Conditioning Orima - Free user manual and instructions

Find the device manual for free ORT-09-R32 Orima in PDF.

📄 81 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Orima ORT-09-R32 - page 56
View the manual : English EN Español ES
Pick your language and provide your email: we'll send you a specifically translated version.
BrandOrima
ModelORT-09-R32
Product TypeSplit Air Conditioner (Wall-Mounted)
RefrigerantR32
Cooling Capacity9000 BTU/h (2.6 kW)
Heating Capacity9000 BTU/h (2.6 kW)
Energy Efficiency Ratio (EER)3.5 (approx.)
Power Supply220-240V ~ 50Hz
Dimensions (Indoor Unit)800 x 285 x 210 mm (WxHxD)
Dimensions (Outdoor Unit)720 x 495 x 265 mm (WxHxD)
Weight (Indoor Unit)10 kg
Weight (Outdoor Unit)25 kg
FunctionsCooling, Heating, Dehumidification, Fan, Auto Mode, Sleep Mode, Timer
ControlRemote Control with LCD Display
Airflow4-Speed Fan (Auto, Low, Medium, High)
FilterWashable and Reusable with Antibacterial Coating
MaintenanceClean filter every 2 weeks; Check drain regularly
Safety FeaturesOverheat Protection, Anti-Freeze, Auto-Restart, Child Lock
Spare PartsRemote Control, Filter (available as accessory)
RepairabilityModular design: mainboard, compressor, fan motor replaceable
Noise Level (Indoor)≤ 40 dB(A) (Low Speed)
Noise Level (Outdoor)≤ 52 dB(A)

Frequently Asked Questions - ORT-09-R32 Orima

How do I clean the air filter?
Open the front panel, remove the filter, wash it with lukewarm water and mild detergent, dry thoroughly, and reinstall. Clean every 2 weeks for optimal performance.
What does error code E1 mean?
Error E1 indicates a room temperature sensor fault. Check sensor connection or contact a technician.
Can I use an extension cord?
No, direct connection to a dedicated wall outlet is required. Extension cords may cause overheating or fire hazard.
How often should I service the outdoor unit?
At least once a year, clean the condenser coils and check for debris. Professional maintenance recommended.
What is the recommended room size for this unit?
Up to 25 m² (approx. 270 ft²) for cooling and heating.
How do I set the timer?
Press TIMER on remote, then use +/- to set desired ON/OFF time. Confirm with SET. Max delay 24 hours.
Why is water leaking from the indoor unit?
Check if the drain pipe is blocked or bent. Clean the pipe and ensure proper slope.
Is R32 refrigerant safe?
R32 is slightly flammable but safe when used properly. The unit has safety valves and leak detection.
How do I reset the unit?
Unplug the unit for 5 minutes, then plug it back in. Or press RESET hole on remote with a pin.
Can I use the air conditioner in winter?
Yes, it has a heating mode (heat pump) effective down to -7°C outdoor temperature.

User questions about ORT-09-R32 Orima

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Air Conditioning in PDF format for free! Find your manual ORT-09-R32 - Orima and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. ORT-09-R32 by Orima.

USER MANUAL ORT-09-R32 Orima

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Orima

Model : ORT-09-R32

Category : Air Conditioning