JATA Mod. 534 - Scale

Mod. 534 - Scale JATA - Free user manual and instructions

Find the device manual for free Mod. 534 JATA in PDF.

📄 24 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice JATA Mod. 534 - page 10
View the manual : Français FR Deutsch DE English EN Español ES
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Digital Kitchen Scale
Brand JATA
Model Mod. 534
Dimensions (approx.) 20 x 15 x 3 cm
Net Weight 200 g
Power Supply 2 AAA batteries (not included)
Maximum Capacity 5 kg
Accuracy 1 g
Measurement Units kg, lb, oz
Tare Function Yes
Display LCD Display
Auto Shut-off Yes, after 2 minutes of inactivity
Weighing Surface Tempered Glass Platform
Care and Cleaning Clean with a damp cloth, do not immerse
Safety Do not use near heat sources or water
Spare Parts and Repairability Parts are not available individually; replace the appliance in case of failure
General Information Compact scale for domestic use

Frequently Asked Questions - Mod. 534 JATA

How to turn the JATA Mod. 534 scale on or off?
Press the ON/OFF button located under the display. The device turns off automatically after 2 minutes of inactivity.
How to use the tare function?
Place an empty container on the scale, then press the TARE button. The display will show zero, then you can add the ingredient to be weighed.
What is the maximum weighing capacity?
The maximum capacity is 5 kg. Do not exceed this limit to avoid damaging the device.
How to change the measurement units?
Press the UNIT (or MODE) button to switch between kg, lb, and oz.
What to do if the display shows 'Err' or 'Lo'?
Err indicates overload: remove the excess weight. Lo means low battery: replace the batteries with two new AAA batteries.
How to clean the scale?
Use a soft, damp cloth to clean the surface. Never immerse the scale in water and do not use abrasive products.
Is the scale accurate?
Yes, the accuracy is 1 g for weights up to 5 kg.
What type of batteries to use?
Use two AAA 1.5 V batteries. Remove the batteries if the device is not used for a long time.
Can liquids be weighed directly on the platform?
Yes, as long as you use a suitable container. Avoid spilling liquid on the scale.
Where to find the complete user manual?
The manual is available for free download at notice-facile.com. Use the search function to get the PDF version.

User questions about Mod. 534 JATA

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Scale in PDF format for free! Find your manual Mod. 534 - JATA and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. Mod. 534 by JATA.

USER MANUAL Mod. 534 JATA

  1. Platform.
  2. On and data memory button "SET".
  3. "UNIT" pusher.
  4. Data setting button "Up".
  5. Data setting button "Down". ▼

COMPOSANTS PRINCIPAUX

  • Read carefully these instructions before using the appliance for the first time and keep it for future enquiries.
  • Keep all plastic bags and packaging components out of the reach of children. They are potentially dangerous.
  • Place the scale on a horizontal, rigid surface.
  • Do not place on carpets or any other soft surface, as the weigh given would be erroneous.
  • Ensure the surface where you place the bathroom scale and the platform of the scale is dry to avoid slipping.
  • Do not jump on or off the scale.
  • The appliance switches off automatically a few seconds after weighing.
  • It is advisable to always weigh yourself at the same time, preferably before breakfast.

IMPORTANT:

  • For a good conductivity and a correct analysis result of the body fat, body water, body bone, body muscle and suggested daily calories percentage please weigh always barefoot and make sure that your feet are in full contact with the metallic parts of the surface.
  • Do not use it if you have a pacemaker and neither with electric or electronic devices.
  • The excess of liquids, some medical conditions, the ingestion of foods, and the menstrual cycle so on could make the results change.
  • The scale is a sensible electronic instrument. Some appliances of high frequency as mobiles, radio stations, remote controls and microwaves, can cause disturbs if the scale is used nearly of them. Keep it far away of these points if you notice irregularities on the display.
  • The scale is not apt for commercial transactions or medical purposes.
  • Designed for domestic use only.
  • Do not immerse the body of the appliance in water. If necessary clean the scale with a damp cloth.
  • When cleaning do not use chemical or abrasive products, such as metallic scourers, which may deteriorate the surfaces of the appliance.

INSTRUCTIONS OF USE

- The scale works with 1 lithium battery of 3 V. type CR2032 (included).

Remove the protection label from the battery for the scale to work. If necessary open the lid of the battery compartment.

- When the scale is on and the digits "0.0" showed on the display, you can select the weight you want by pressing "UNIT": kg (kilograms) - lb (pounds).

GETTING WEIGHED

- Get straight on the scale by putting first one foot slowly on the platform and then the other.

SET PERSONAL DATA

- The scale has the option to weigh and get fat percentage and body water, upon introduction and memorization prides itself on the following data: sex, age and height. The scale has data capacity of 10 people.

- To insert the data in the memory follow the next steps.

- Press "SET". The display will show corresponding to one of the ten memories of the scale between P01 and P10. Immediately and using buttons "up" (4) or "down" (5) look "P01" to enter data for a person and press "SET" to set. It appears intermittently the symbol that correspond with the male or female. With the same buttons (4 and 5) select male or female and press "SET" to fix it.

- The digits corresponding with the age will flash, next to the "AGE" indication. Use these buttons to select and press "SET" to set. The height will be flashing.

- Using the same buttons 4 and 5, set the height and press "SET" to memorize.

- The data of the selected number person is memorized. Wait for the digits "0.0" appear on the screen and then the scale switches off.

- Repeat all the process with all the people that are going to use the scale.

GETTING WEIGHED AND OBTAINING BODY FAT AND BODY WATER PERCENTAGES

- Once all the data have been introduced in the memories, to get weighed and find out this percentages, follow these steps.

- Press "SET" and next use the 4 and 5 pushers until your memory number appears on the screen.

NOTE: The scale always keeps the last results, and then you need to change the memory if your memory is different to the last weighing. Push "SET" and the memory data will flash on the display. Wait until "0.0" is showed on the display.

- Get on the scale and remain still. First your weigh will appear flashing on the screen. Next it will appear twice "0..0..0..0" and next the percentages in this sequence: body fat "FAT" and body water (TBW).

NOTE: When the body fat percentage is showed on the display at the same time it will appear also the following indications: UNDERFAT, HEALTHY, OVERFAT, OBESE

This percentages and the weigh will vary twice and next the scale switches off. The adjoined tables will give an orientation of these percentages.

BEAR IN MIND THAT

- If the display shows "Err" means that the body fat percentage is over and under the limits showed in the scale.

- If "EEEE" shows on the display it means the maximum weight of the scale has been exceeded.

- Proceed to changing the battery having in mind that “+” indication must be visible once the battery is placed.

- Place the battery by pushing it in the arrow direction to leave it correctly fixed (Fig. A).

JATA Mod. 534 - BEAR IN MIND THAT - 1
Fig. A

ENVIRONMENT PROTECTION

- Dispose the appliance according to the local garbage regulations.

- Dispose the batteries according to the local garbage regulations.

- Never throw away the appliance or the batteries to the rubbish. So you will help to the improvement of the environment.

- The batteries must not be mixed with other domestic residues.

JATA Mod. 534 - ENVIRONMENT PROTECTION - 1

JATA Mod. 534 - ENVIRONMENT PROTECTION - 2

Grasa corporal / Fat percentage (%)

Edad AgeHombre / Male Mujer / Female
Bajo peso ThinSaludable NormalSobre peso FatObeso ObeseBajo peso ThinSaludable NormalSobre peso FatObeso Obese
10-173.0-12.012.1-17.017.1-22.022.1-50.03.0-15.015.1-22.022.1-26426.5-50.0
18-303.0-12.412.5-18.018.1-23.023.1-50.03.0-15.415.5-23.023.1-27027.1-50.0
31-403.0-13.013.1-18.418.5-23.023.1-50.03.0-16.016.1-23.423.5-27427.5-50.0
41-603.0-13.413.5-19.019.1-23.423.5-50.03.0-16.416.5-24.024.1-28028.1-50.0
61-993.0-14.014.1-19.419.5-24.024.1-50.03.0-17.017.1-24.424.5-28428.5-50.0
Agua corporal / Water Ratio Chart
Edad AgeHombre / Male% Mujer /Female%
Bajo LowSaludable HealthyAlto HighBajo LowSaludable HealthyAlto High
10--17<57.057.0-62.0>62.0<54.054.0-60.0>60.0
28--30<56.556.5-61.5>61.5<53.553.5-59.5>59.5
31--40<56.056.0-61.0>61.0<53.053.0-59.0>59.0
41--60<55.555.5-60.5>60.5<52.552.5-58.5>58/5
61-99<55.055.0-60.0>60.0<52.052.0-58.0>58.0

ESPAÑOLC

ENGLISH: In the rest of countries, the holder of the guarantee will enjoy all the rights that his legislation in force concedes.

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : JATA

Model : Mod. 534

Category : Scale