| Product type | Heating blanket |
| Brand | Medisana |
| Model | HP 622 |
| Dimensions | 180 x 130 cm |
| Weight | 1.5 kg |
| Power supply | 220-240 V ~ 50/60 Hz |
| Power | 100 W |
| Number of heat levels | 6 levels |
| Automatic shut-off function | Yes, after 3 hours |
| Overheat protection | Yes, with integrated sensor |
| Machine washable | Yes, up to 30 °C |
| Material | Microfleece |
| Color | White or grey (depending on availability) |
| Cable length | 2.5 m |
| Controls | Rotary knob with illumination |
| Display | Level LED |
| Usage | On bed or sofa |
| Certifications | CE, Oeko-Tex Standard 100 |
| Warranty | 2 years |
| Package contents | Blanket, user manual |
Frequently Asked Questions - HP 622 MEDISANA
User questions about HP 622 MEDISANA
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Heated blanket in PDF format for free! Find your manual HP 622 - MEDISANA and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. HP 622 by MEDISANA.
USER MANUAL HP 622 MEDISANA
Tested for harmful substances.
www.oeko-tex.com/standard100

Art. 61156


Gebrauchsanweisung
Instruction Manual
Mode d'emploi
Please read carefully!
1 Safety Information 8
2 Operating 12
3 Miscellaneous ....13
4 Warranty 14
FR Mode d'emploi
Please fold out this page and leave it folded out for quick reference.
Heat pad for neck and shoulder
Control unit with sliding switch
Read the instruction manual carefully before using this device, especially the safety instructions, and keep the instruction manual for future use.
Should you give this device to another person, it is vital that you also pass on these instructions for use.
Explanation of symbols

This instruction manual belongs to this device.
It contains important information about starting up and operation.
Read the instruction manual thoroughly.
Non-observance of these instructions can result in serious injury or damage to the device.

WARNING
These warning notes must be observed to prevent any injury to the user.

CAUTION
These notes must be observed to prevent any damage to the device.

NOTE
These notes give you useful additional information on the installation or operation.

Protection category II

Lot number

Manufacturer

Do not puncture the heated cushion!

Do not use the heated cushion when it is folded!

Not to be used by very young children (0-3 years)!

Only use the heated cushion indoors!

40° Delicate wash!

Do not bleach!

Do not dry the heated cushion in a tumble drier!
You may dry the cushion cover in a tumble drier!

Do not iron the heated cushion! You may iron the cushion cover at a low temperature!

Do not dry clean!
- Carefully check the heat pad before each use for damages or wear and tear.
- Do not use if you notice wear, damage or signs of improper use on the device, the switch or the cables or if the device is not working.
- Before connecting the device to your power supply, please ensure that the supply voltage stated on the rating plate is compatible with your mains supply.
- Do not fold or crease the heat pad during use.
- Neither pierce the pad with, nor attach safety pins or other spiky or sharp objects to the pad.
- Do not use the device on children or persons who are disabled, asleep or insensitive to heat (persons who cannot react on overheating).
- Children below the age of 3 years are not allowed to use this device, because they are not able to react on overheating.
- The device must not be used by young children over the age of 3 years, unless the control unit has been adjusted accordingly by its parents or legal guardians or unless the child has been well instructed how to use the control unit properly.
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
• Children shall not play with the appliance. - Cleaning and user maintenance shall not be made by children without supervision.
- Never use the pad unsupervised.
- The unit is designed for home use only.
- Do not fall asleep while the heat pad is switched on.
-
Prolonged use of the heated cushion at a high setting could lead to skin burns.
-
Do not cover the pad with any other cushions. The control switch should not be covered or placed on or below the pad while the unit is in operation.
- Do not sit on the heat pad. Instead, rest the pad on or against the part of the body to be treated.
- Never touch a heat pad that has fallen into water. Unplug the unit from the mains outlet immediately.
- Keep the mains lead away from hot surfaces.
- Never carry, pull or turn the heat pad by the mains lead and do not let the lead get tangled.
- Do not use the heat pad when wet and only use it in dry environments (not in the bathroom or similar environments).
- The controls and leads must not be exposed to any kind of moisture.
- If a fault occurs, do not attempt to repair the unit yourself. Repairs must only be carried out by an authorized specialist dealer or other suitably qualified personnel.
- If the power supply cable is damaged, it may only be replaced by MEDISANA, an authorised dealer or by qualified personnel. In order to prevent hazards, always send the unit in to the service centre.
- The heat pad may only be operated with the control unit (HP 622) supplied.
- When storing the heat pad, allow it to cool down before folding.
- Should you have any concerns about health issues, consult your doctor before using the heat pad.
- Do not use the heat pad on parts of the body that are swollen, injured or inflamed.
- Should you experience persistent pains in the muscles and joints, please inform your doctor. Persistent pains can be a symptom of serious illness.
- If you experience any pain or discomfort while using the unit, stop using it immediately.
- The device is only for private use and is not to be used in hospitals.
Thank you very much for your confidence in us and congratulations!
With this Heat pad for neck and shoulder you have purchased a quality product by MEDISANA. To ensure the best results and long-term satisfaction with your Heat pad for neck and shoulder, we recommend that you read the following operating and maintenance instructions carefully.
2.1 Items supplied and packaging
Please check first of all that the unit is complete and is not damaged in any way. If in doubt, do not use the appliance. Send it to a service point.
The following parts are included:
• 1 MEDISANA Heat pad for neck and shoulder HP 622 with removable control unit
• 1 Instruction manual

The packaging can be reused or recycled. Please dispose properly of any packaging material no longer required. If you notice any transport damage during unpacking, we contact your dealer without delay.

WARNING
Please ensure that the polythene packing is kept away from the reach of children! Risk of suffocation!
2.2 Operation
You can use the MEDISANA Heat pad for neck and shoulder HP 622 to gently warm and relax these parts of the body. Using the heat pad stimulates blood circulation in hardened muscles and helps you to relax after a strenuous day. The heat pad features an electric temperature control that regulates the temperature according to the chosen setting.
Make sure, the connection cable of the control unit is properly connected to the plug of the heat pad. Plug the unit into the mains outlet and move the slider control from position 0 to position 1. The power LED will light up. When switching up and down the different levels, the indicator lamp flashes twice briefly and then comes on permanently.
After a few minutes you will be able to feel the pad getting noticeably warmer. If you require a higher temperature setting, move the switch to the next position 2, 3, 4, 5 or the maximum heat setting, position 6. If the heat pad gets too hot for you, move the slider back to position 5, 4, 3, 2 or 1. After a short time, the heat pad will cool down.
Level 2 - 6 of the device is intended for heating up, only level 1 is for continuous operation.
To switch the unit off, move the switch back to position 0. The power LED will go out, indicating that the unit is switched off. Unplug the unit from the mains outlet.
Move the switch to position 1 for any continuous use. The heat pad will switch off automatically after approx. 90 minutes of continuous use. To switch it back on again, move the slider switch to position 0 and then back to the desired heat setting. Unplug the unit from the mains outlet once you have finished using it.
3.1 Cleaning and maintenance
- Before cleaning the pad, unplug it from the mains outlet and let it cool down for at least ten minutes.
- The heat pad is equipped with a removable control unit. Unplug the control unit from the heat pad by pulling out the connection cable from the plug on the heat pad.
- The heat pad can be cleaned with a soft brush when dry.
- The appliance can be machine washed at 40° in a delicate programme or by hand gently. The best way to do this is to put the heated underblanket in a bath with lukewarm water and some mild detergent and then gently squeeze it out
- Rinse the pad several times to get rid of any remaining detergent.
- Never use strong detergents or hard brushes.
- To dry, lay the pad flat on a moisture-absorbent towel or mat.
- Only use the blanket again once it is completely dry.
- Reconnect the control unit to the heat pad in the correct manner (please see the sketch, the arrow markings are showing towards each other).
- You should untangle the cable from time to time.
- Store the unit in a clean and dry place, laid out flat with nothing covering or resting on top of it.
- Do not crease the appliance by placing items on top of it during storage.
3.3 Disposal

This product must not be disposed together with the domestic waste. All users are obliged to hand in all electrical or electronic devices, regardless of whether or not they contain toxic substances, at a municipal or commercial collection point so that they can be disposed of in an environmentally acceptable manner. Consult your municipal authority or your dealer for information about disposal.
3.4 Technical specifications
Name and model : MEDISANA Heat pad for neck and shoulder HP 622
Voltage, frequency : 220-240V\~ 50Hz
Heat output : 100 watts
Automatic switch off : After approx. 90 minutes
Dimensions approx. : approx. 56 x 52 cm
Weight approx. : approx. 0.5 kg
Mains lead length approx. : approx. 2 m
Operating conditions : Only use in dry rooms as described in the operating instructions
Storage conditions : Clean and dry
Art. no. : 61156
EAN no. : 40 15588 61156 8



In accordance with our policy of continual product improvement, we reserve the right for technical and design changes without notice.
The current version of this instruction manual can be found under www.medisana.com
4.1 Warranty and repair terms
Please contact your supplier or the service centre in case of a claim under the warranty. If you have to return the unit, please enclose a copy of your receipt and state what the defect is.
The following warranty terms apply:
- The warranty period for MEDISANA products is three years from date of purchase. In case of a warranty claim, the date of purchase has to be proven by means of the sales receipt or invoice.
- Defects in material or workmanship will be removed free of charge within the warranty period.
- Repairs under warranty do not extend the warranty period either for the unit or for the replacement parts.
-
The following is excluded under the warranty:
a. All damage which has arisen due to improper treatment, e.g. non-observance of the user instructions.
b. All damage which is due to repairs or tampering by the customer or unauthorised third parties.
c. Damage which has arisen during transport from the manufacturer to the consumer or during transport to the service centre.
d. Accessories which are subject to normal wear and tear. -
Liability for direct or indirect consequential losses caused by the unit are excluded even if the damage to the unit is accepted as a warranty claim.

MEDISANA GmbH
Jagenbergstraße 19
41468 NEUSS
GERMANY
The service centre address is shown on the attached leaflet.