Product Type Medical Color LCD Monitor
Brand Sony
Model LMD-2451MD
Screen Size 24 inches (diagonal)
Native Resolution 1920 x 1200 pixels
Brightness 300 cd/m²
Contrast Ratio 1000:1
Viewing Angle 178° horizontal / 178° vertical
Dimensions (W x H x D) 560 x 380 x 100 mm
Weight Approx. 8 kg
Power Supply 100-240 V AC, 50/60 Hz
Power Consumption 75 W (max)
Video Inputs Composite, S-Video, RGB, DVI-D, SDI
Video Outputs SDI (loop), DVI-D
Main Functions Medical display, calibration, alarm, center marker
Maintenance and Cleaning Clean with a soft dry cloth, avoid solvents
Safety Compliant with medical standards (IEC 60601-1)
Spare Parts and Repairability Parts available through Sony after-sales service

Frequently Asked Questions - LMD-2451MD SONY

How to turn on the Sony LMD-2451MD monitor?
Press the Power button located on the front panel. The green LED lights up when the device is on.
What video inputs are available?
The monitor has Composite, S-Video, RGB, DVI-D, and SDI inputs. Use the menu to select the source.
How to clean the screen?
Use a soft dry cloth. For stubborn stains, lightly dampen the cloth with water. Never use solvents or abrasive products.
What to do if no image appears?
Check that the cable is properly connected and that the source is on. Make sure the correct input is selected via the Input Select menu. If the problem persists, restart the monitor.
How to adjust brightness and contrast?
Press the Menu button, then go to the Picture settings. Use the arrow keys to adjust brightness and contrast.
Is the monitor compatible with 1080p signals?
Yes, the LMD-2451MD supports resolutions up to 1920x1200, including 1080p via DVI-D and SDI inputs.
How to use the alarm function?
The alarm function can be activated in the Alarm menu. It emits an audio and visual signal in case of signal loss or fault.
Can I mount the monitor on an articulated arm?
Yes, the monitor is compatible with a VESA 100x100 mm mount. Use a suitable bracket.
What is the power consumption in standby?
In standby mode, power consumption is approximately 0.5 W.
Where to find the serial number?
The serial number is printed on a label on the back of the monitor, next to the power input.

User questions about LMD-2451MD SONY

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

Your email remains private: it is only used to notify you if someone answers your question.

No questions yet. Be the first to ask one.

Download the instructions for your Monitor in PDF format for free! Find your manual LMD-2451MD - SONY and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. LMD-2451MD by SONY.

USER MANUAL LMD-2451MD SONY

© 2009 Sony Corporation

SONY LMD-2451MD - 1

For safety

① Tally lamp

①/ ▼ (equipotential / functional earth) terminal

(equipotential) terminal

Connect the equipotential plug.

To disconnect the power cord

3 Secure with screws.

Diagram of a device rear panel with screwdriver and connector (no text or labels).

How to remove the terminal cover

Diagram showing a transformation from a rectangular block with two circles to a square divided into four equal circles (no text or symbols present).

Aspect

APA (Auto Pixel Alignment)

Before operating the unit, please read this manual thoroughly and retain it for future reference.

Owner's Record

The model and serial numbers are located at the rear. Record these numbers in the spaces provided below. Refer to these numbers whenever you call upon your Sony dealer regarding this product.

Model No. ____ Serial No. ____

WARNING

To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.

To avoid electrical shock, do not open the cabinet. Refer servicing to qualified personnel only.

No modification of this apparatus is allowed.

WARNING: THIS APPARATUS MUST BE EARTHED.

WARNING

To disconnect the main power, unplug the AC plug. When installing the unit, incorporate a readily accessible disconnect device in the fixed wiring, or connect the power plug to an easily accessible socket-outlet near the unit. If a fault should occur during operation of the unit, operate the disconnect device to switch the power supply off, or disconnect the power plug.

CAUTION

This LCD monitor should only be used with a specified monitor stand. For information on suitable stands, refer to “Specifications.” Installation of the LCD monitor on any other stand may result in instability, possibly leading to injury.

WARNING:

Using this unit at a voltage other than 120 V may require the use of a different line cord or attachment plug, or both. To reduce the risk of fire or electric shock, refer servicing to qualified service personnel.

CAUTION

The apparatus shall not be exposed to dripping or splashing. No objects filled with liquids, such as vases, shall be placed on the apparatus.

Do not install the appliance in a confined space, such as book case or built-in cabinet.

CAUTION

The unit is not disconnected from the AC power source (mains) as long as it is connected to the wall outlet, even if the unit itself has been turned off.

WARNING

Make sure the surface is wide enough so that this apparatus's width and depth don't exceed the surface's edges.

If not, this apparatus may lean or fall over and cause an injury.

Consult with Sony qualified personnel for mounting arm, wall or ceiling mount installation.

Indications for Use/Intended Use

The Sony LMD-2451MD LCD Monitor is intended to provide color video displays of images from surgical camera systems. The LMD-2451MD is a widescreen, high definition monitor for real-time use during minimally invasive surgical procedures including arthroscopy (orthopedic surgery), laparoscopy (general and gynecological surgery), thoracoscopy, endoscopy (general, gastroenterological and ENT surgery) and general surgery.

For the customers in Norway (For kundene i Norge)

For the customers in the U.S.A.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment.

All interface cables used to connect peripherals must be shielded in order to comply with the limits for a digital device pursuant to Subpart B of part 15 of FCC Rules.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Symbols on the unit

SymbolLocation This symbol indicates
SONY LMD-2451MD - For the customers in the U.S.A. - 1Bottom Power switch. Press to turn the monitor on.
SONY LMD-2451MD - For the customers in the U.S.A. - 2Bottom Power switch. Press to turn the monitor off.
SONY LMD-2451MD - For the customers in the U.S.A. - 3Rear The equipotential terminal which brings the various parts of a system to the same potential.
SONY LMD-2451MD - For the customers in the U.S.A. - 4Rear Functional earth terminal
SONY LMD-2451MD - For the customers in the U.S.A. - 5Front Key inhibitThe setting are locked so that they cannot be changed.

SONY LMD-2451MD - For the customers in the U.S.A. - 6

This symbol is located on the rear of the unit. See page 60 of these instructions for details about how to attach the connector cover.

SONY LMD-2451MD - For the customers in the U.S.A. - 7

Refer to the operating instructions

Follow the directions in the operating instructions for parts of the unit on which this mark appears.

SONY LMD-2451MD - Refer to the operating instructions - 1

This symbol indicates the manufacturer, and appears next to the manufacturer's name and address.

SONY LMD-2451MD - Refer to the operating instructions - 2

This symbol indicates the European

Community representative, and appears next to the European Community representative's name and address.

Caution

When you dispose of the unit or accessories, you must obey the laws in the relative area or country and the regulations in the relative hospital.

WARNING on power connection

Use a proper power cord for your local power supply.

  1. Use the approved Power Cord (3-core mains lead) / Appliance Connector / Plug with earthing-contacts that conforms to the safety regulations of each country if applicable.
  2. Use the Power Cord (3-core mains lead) / Appliance Connector / Plug conforming to the proper ratings (Voltage, Ampere). If you have questions on the use of the above Power Cord / Appliance Connector / Plug, please consult a qualified service personnel.

WARNING on power connection for medical use

Please use the following power supply cord. With connectors (plug or female) and cord types other than those indicated in this table, use the power supply cord that is approved for use in your area.

United States and Canada
Plug Type HOSPITAL GRADE*
Cord Type Min. TypeSJTMin. 18 AWG
Minimum Rating for Plug and Appliance Couplers10A/125V
Safety Approval ULListed and CSA

*Note: Grounding reliability can only be achieved when the equipment is connected to an equivalent receptacle marked 'Hospital Only' or 'Hospital Grade'.

For the customers in Canada

This Class A digital apparatus complies with Canadian ICES-003.

This unit has been certified according to Standard CAN/CSA-C22.2 No.60601-1.

For the customers in the U.S.A and Canada

When you use this product connected to 240 V single phase, be sure to connect this product to a center tapped circuit.

Important safeguards/notices for use in the medical environments

  1. All the equipments connected to this unit shall be certified according to Standard IEC60601-1, IEC60950-1, IEC60065 or other IEC/ISO Standards applicable to the equipments.
  2. Furthermore all configurations shall comply with the system standard IEC60601-1-1.

Everybody who connects additional equipment to the signal input part or signal output part configures a medical system, and is therefore, responsible that the system complies with the requirements of the system standard IEC60601-1-1. If in doubt, consult the qualified service personnel.

  1. The leakage current could increase when connected to other equipment.
  2. For this particular equipment, all accessory equipment connected as noted above, must be connected to mains via an additional isolation transformer conforming with the construction requirements of IEC60601-1 and providing at least Basic Insulation.
  3. This equipment generates, uses, and can radiate radio frequency energy. If it is not installed and used in accordance with the instruction manual, it may cause interference to other equipment. If this unit causes interference (which can be determined by unplugging the power cord from the unit), try these measures: Relocate the unit with respect to the susceptible equipment. Plug this unit and the susceptible equipment into different branch circuit.

Consult your dealer. (According to standard EN60601-1-2 and CISPR11, Class B, Group 1)

  1. Model LMD-2451MD is a monitor intended for use in a medical environment to display pictures from cameras or other systems, other than diagnostic X-ray equipment.

Important EMC notices for use in the medical environments

  • The LMD-2451MD needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided in this instructions for use.
  • The portable and mobile RF communications equipment such as cellular phones can affect the LMD-2451MD.

Warning

The use of accessories and cables other than those specified, with the exception of replacement parts sold by Sony Corporation, may result in increased emissions or decreased immunity of the LMD-2451MD.

Guidance and manufacturer's declaration-electromagnetic emissions
The LMD-2451MD is intended for use in the electromagnetic environment specified below.The customer or the user of the LMD-2451MD should assure that it is used in such an environment.
Emission test Compliance Electromagnetic environment-guidance
RF emissionsCISPR 11Group 1The LMD-2451MD uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment.
RF emissionsCISPR 11Class BThe LMD-2451MD is suitable for use in all establishments, including domestic establishments and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes.
Harmonic emissionsIEC 61000-3-2Class D
Voltage fluctuations/flicker emissionsIEC 61000-3-3Complies

Warning

If the LMD-2451MD should be used adjacent to or stacked with other equipment, it should be observed to verify normal operation in the configuration in which it will be used.

Guidance and manufacturer's declaration - electromagnetic immunity
The LMD-2451MD is intended for use in the electromagnetic environment specified below. The customer or the user of the LMD-2451MD should assure that it is used in such as environment.
Immunity testIEC 60601 test levelCompliance level EElectromagnetic environment - guidance
Electrostatic discharge (ESD)±6 kV contact±6 kV contactFloors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30%.
±8 kV air±8 kV air
IEC 61000-4-2
Electrical fast transient/burst±2 kV for power supply lines±2 kV for power supply linesMains power quality should be that of a typical commercial or hospital environment.
IEC 61000-4-4±1 kV for input/output lines±1 kV for input/output lines
Surge±1 kV differential mode±1 kV differential modeMains power quality should be that of a typical commercial or hospital environment.
IEC 61000-4-5±2 kV common mode±2 kV common mode
Voltage dips, short interruptions and voltage variations on power supply input lines<5% UT (>95% dip in UT )for 0.5 cycle<5% UT (>95% dip in UT )for 0.5 cycleMains power quality should be that of a typical commercial or hospital environment. If the user of the LMD-2451MD requires continued operation during power mains interruptions, it is recommended that the LMD-2451MD be powered from an uninterruptible power supply or a battery.
IEC 61000-4-1140% UT (60% dip in UT )for 5 cycles40% UT (60% dip in UT )for 5 cycles
70% UT (30% dip in UT )for 25 cycles70% UT (30% dip in UT )for 25 cycles
<5% UT (>95% dip in UT )for 5 sec<5% UT (>95% dip in UT )for 5 sec
Power frequency (50/60Hz)magnetic field3 A/m 3 A/m Power frequency magnetic fields should be at least characteristic of a typical location in a typical commercial or hospital environment.
IEC 61000-4-8
NOTE: UT is the a.c. mains voltage prior to application of the test level.
Immunity testIEC 60601 ttest levelCompliance level Eelectromagnetic environment - guidance
Conducted RF3 Vrms3 VrmsPortable and mobile RF communications equipment should be used no closer to any part of the LMD-2451MD, including cables, than the recommended separation distance calculated from the equation appliance to the frequency of the transmitter.
IEC 61000-4-6150 kHz to 80 MHzRecommended separation distance d = 1.2 d = 1.2 80 MHz to 800 MHz d = 2.3 800 MHz to 2.5 GHz
Radiated RF3 V/m3 V/mWhere P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in meters (m).Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey, a should be less than the compliance level in each frequency range. b Interference may occur in the vicinity of equipment marked with following symbol:SONY LMD-2451MD - Warning - 1
IEC 61000-4-380 MHz to 2.5 GHz
NOTE 1: At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.
a Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the LMD-2451MD is used exceeds the applicable RF compliance level above, the LMD-2451MD should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the LMD-2451MD.b Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.Recommended separation distances between portable and mobile RF communications equipment and the LMD-2451MD
The LMD-2451MD is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the LMD-2451MD can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (Transmitters) and the LMD-2451MD as recommended below, according to the maximum output power of the communications equipment.
Rated maximum output power of transmitter WSeparation distance according to frequency of transmitter m
150 kHz to 80 MHz d = 1.2 80 MHz to 800 MHz d = 1.2 800 MHz to 2.5 GHz d = 2.3
0.01 0.12 0.12 0.23
0.1 0.38 0.38 0.73
11.
10 3.8 3.8 7.3
100 12 12 23
For transmitters rated a maximum output power not listed above, the recommended separation distance d in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.NOTE 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.

For the customers in the U.S.A.

SONY LIMITED WARRANTY - Please visit http://

www.sony.com/psa/warranty for important information and complete terms and conditions of Sony's limited warranty applicable to this product.

For the customers in Canada

SONY LIMITED WARRANTY - Please visit http://

www.sonybiz.ca/pro/lang/en/ca/article/resources-warranty-product-registration for important information and complete terms and conditions of Sony's limited warranty applicable to this product.

For the customers in Europe

Sony Professional Solutions Europe - Standard Warranty and Exceptions on Standard Warranty. Please visit http://www.pro.sony.eu/warranty for important information and complete terms and conditions.

For the customers in Korea

SONY LIMITED WARRANTY - Please visit http://bpeng.sony.co.kr/handler/BPAS-Start for important information and complete terms and conditions of Sony's limited warranty applicable to this product.

Table of Contents

Precaution 50

On Safety 50

On Installation 50

About the LCD Display Panel 50

On Burn-in 50

On a Long Period of Use 50

On Cleaning 50

Disposal of the Unit 51

Recommendation to Use more than One Unit 51

On Repacking 51

On Fan Error 51

On Moisture Condensation 51

Precautions for using this unit safely 51

Precautions for connecting this unit with other medical devices 51

On simultaneous use with a radio knife, etc. .... 52

Features 52

Location and Function of Parts and

Controls 54

Front Panel 54

Input Signals and Adjustable/Setting Items ..... 56

Rear/Bottom Panel 57

Connecting the AC Power Cord ....59

Installing the Input Adaptor ....60

Removing the Connector Cover 60

Selecting the Default Settings 61

Selecting the Menu Language 62

Using the Menu 63

Loading USER MEMORY 65

Adjustment Using the Menus ....65

Items 65

Adjusting and Changing the Settings 66

STATUS menu.... 66

COLOR TEMP/SPACE menu 67

USER CONTROL menu.... 67

USER CONFIG menu.... 69

REMOTE menu 73

KEY INHIBIT menu.... 74

USER MEMORY menu.... 74

Saving the user memory.... 74

Troubleshooting 76

Specifications 76

Dimensions 84

Precaution

On Safety

  • Operate the unit on 100-240 V AC only.
  • The nameplate indicating operating voltage, etc. is located on the AC adaptor.
  • Should any solid object or liquid fall into the cabinet, unplug the unit and have it checked by qualified personnel before operating it any further.
  • Unplug the unit from the wall outlet if it is not to be used for several days or more.
  • To disconnect the AC power cord, pull it out by grasping the plug. Never pull the cord itself.
  • The socket-outlet shall be installed near the equipment and shall be easily accessible.

On Installation

  • Prevent internal heat build-up allowing adequate air circulation. Do not place the unit on surfaces (rugs, blankets, etc.) or near materials (curtains, draperies) that may block the ventilation holes.
  • Do not install the unit near heat sources such as radiators or air ducts, or in a place subject to direct sunlight, excessive dust, mechanical vibration or shock.
  • Do not place the monitor near equipment which generates magnetism, such as a transformer or high voltage power lines.

About the LCD Display Panel

  • The LCD panel fitted to this unit is manufactured with high precision technology, giving a functioning pixel ratio of at least 99.99%. Thus a very small proportion of pixels may be “stuck”, either always off (black), always on (red, green, or blue), or flashing. In addition, over a long period of use, because of the physical characteristics of the liquid crystal display, such “stuck” pixels may appear spontaneously. These problems are not a malfunction.
  • Do not leave the LCD screen facing the sun as it can damage the LCD screen. Take care when you place the unit by a window.
  • Do not push or scratch the LCD monitor's screen. Do not place a heavy object on the LCD monitor's screen. This may cause the screen to lose uniformity.
  • If the unit is used in a cold place, a residual image may appear on the screen. This is not a malfunction. When

the monitor becomes warm, the screen returns to normal.

- The screen and the cabinet become warm during operation. This is not a malfunction.

On Burn-in

For LCD panel, permanent burn-in may occur if still images are displayed in the same position on the screen continuously, or repeatedly over extended periods.

Images that may cause burn-in

  • Masked images with aspect ratios other than 16:10 • Color bars or images that remain static for a long time
  • Character or message displays that indicate settings or the operating state

To reduce the risk of burn-in

  • Turn off the character displays Press the MENU button to turn off the character displays. To turn off the character displays of the connected equipment, operate the connected equipment accordingly. For details, refer to the operation manual of the connected equipment.
  • Turn off the power when not in use Turn off the power if the monitor is not to be used for a prolonged period of time.

On a Long Period of Use

Due to the characteristics of LCD panel, displaying static images for extended periods, or using the unit repeatedly in a high temperature/high humidity environments may cause image smearing, burn-in, areas of which brightness is permanently changed, lines, or a decrease in overall brightness.

In particular, continued display of an image smaller than the monitor screen, such as in a different aspect ratio, may shorten the life of the unit.

Avoid displaying a still image for an extended period, or using the unit repeatedly in a high temperature/high humidity environment such as an airtight room, or around the outlet of an air conditioner.

To prevent any of the above issues, we recommend reducing brightness slightly, and turning off the power whenever the unit is not in use.

On Cleaning

Before cleaning

Be sure to disconnect the AC power cord from the AC outlet.

On cleaning the monitor

A material that withstands disinfection is used for the front protection plate of the medical use LCD monitor. The protection plate surface is especially treated to reduce reflection of light. When solvents such as benzene or thinner, or acid, alkaline or abrasive detergent, or chemical cleaning cloth are used for the protection plate surface/monitor surface, the performance of the monitor may be impaired or the finish of the surface may be damaged. Take care with respect to the following:

  • Clean the protection plate surface/monitor surface with a 50 to 70 v/v% concentration of isopropyl alcohol or a 76.9 to 81.4 v/v% concentration of ethanol using a swab method. Wipe the protection plate surface gently (wipe using less than 1 N force).
  • Stubborn stains may be removed with a soft cloth such as a cleaning cloth lightly dampened with mild detergent solution using a swab method and then clean using the above chemical solution. Never use solvents such as benzene or thinner, or acid, alkaline or abrasive detergent, or chemical cleaning cloth for cleaning or disinfection, as they will damage the protection plate surface/monitor surface.
  • Do not use unnecessary force to rub the protection plate surface/monitor surface with a stained cloth. The protection plate surface/monitor surface may be scratched.
  • Do not keep the protection plate surface/monitor surface in contact with a rubber or vinyl resin product for a long period of time. The finish of the surface may deteriorate or the coating may come off.

Disposal of the Unit

Do not dispose of the unit with general waste. Do not include the monitor with household waste.

Recommendation to Use More than One Unit

As problems can occasionally occur for the monitor, when the monitor is used for safety control of personnel, assets or stable picture, or for emergencies, we strongly recommend you use more than one unit or prepare a spare unit.

On Repacking

Do not throw away the carton and packing materials. They make an ideal container in which to transport the unit.

If you have any questions about this unit, contact your authorized Sony dealer.

On Fan Error

The fan for cooling the unit is built in. When the fan stops and the RETURN button on the front panel blinks for fan error indication, turn off the power and contact an authorized Sony dealer.

On Moisture Condensation

If the unit is brought directly from a cold place to a warm place, or the unit is warm and the ambient temperature cools suddenly (by air-conditioning, for example), moisture may condense on the surface or inside of the unit, or create a mist residue inside the protection plate.

This is called moisture condensation, and is not a malfunction of the product itself, although it may cause damage to the unit.

Leave the unit in a condensation free area.

If moisture condensation has occurred, turn off the unit and do not use it until moisture condensation has evaporated.

Precautions for using this unit safely

- Some people may experience discomfort (such as eye strain, fatigue, or nausea) while watching video images. Sony recommends that all viewers take regular breaks while watching video images. The length and frequency of necessary breaks will vary from person to person. You must decide what works best. If you experience any discomfort, you should stop watching the video images until the discomfort ends; consult a doctor if you believe necessary.

- Avoid watching the display in environments where your head may shake, or while you are walking or performing exercise, because there is a higher possibility that you experience discomfort.

Precautions for connecting this unit with other medical devices

Before you utilize this device and/or connect this device to any other medical device, please be aware of and abide by the following precautions:

(a) Before actually using this device for medical practice, please check and confirm that you do not experience any discomfort in your use that could be disruptive or impeditive in conducting your intended activity or medical practice.

(b) If you experience or are likely to experience such discomfort, please refrain from using this device.

(c) Generally, discomfort (such as eye strain, fatigue,

(a) Before actually using this device for medical practice, please check and confirm that you do not experience any discomfort in your use that could be disruptive or impeditive in conducting your intended activity or medical practice. (b) If you experience or are likely to experience such discomfort, please refrain from using this device. (c) Generally, discomfort (such as eye strain, fatigue,

nausea, or motion sickness) can be provoked by such factors as quick movements or shakiness of video picture, focal position of video pictures, distance between objects and image capturing modules, user's point of gaze in video pictures, other varying conditions of video pictures to be input to this device, and individual user's health conditions.

On simultaneous use with a radio knife, etc.

If this unit is used together with a radio knife, etc., the picture may be disturbed, warped or otherwise abnormal as a result of strong radio waves or voltages from the device. This is not a malfunction.

When you use this unit simultaneously with a device from which strong radio waves or voltages are emitted, confirm the effect of this before using such devices, and install this unit in a way that minimizes the effect of radio wave interference.

Features

Compliance with medical safety standards in U.S.A., Canada and Europe

IEC 60601-1 and product safety standards in the U.S.A., Canada and Europe have been obtained for this monitor. The monitor is designed for use in the medical treatment field, with the sheet switch, screen protect panel, etc.

Picture

Fully digital 10-bit signal processing circuit

As well as digital signals, all signals including analog signals are converted into digital signals. All signals are processed using a fully digital 10-bit processing circuit so that an image is produced in smooth gradation without any deterioration of quality.

Two color system available

The monitor can display NTSC and PAL signals by connecting this unit.

Auto chroma/phase function

The chroma and phase of the decoder are automatically adjusted with the auto chroma phase function.

High image-quality/high-resolution WUXGA LCD panel

An WUXGA high-resolution (1,920 × 1,200 dots) panel and high brightness/ultra-wide field of view technology enable you to use the monitor under various lighting conditions and in numerous ways (installing on wall, using several monitors to view an image, and so on.). Because a color filter with wide-color reproduction and LCD materials with high response speed are used, the motion picture of the video signal is displayed clearer. This monitor also performs sampling of signals at high frequencies and provides a high resolution of 700 TV scanning lines or more during the RGB or component signal (480/60I, 575/50I) input.

Input

Accepts analog RGB input signals *1

Adopting the scan converter allows this monitor to detect VGA, SVGA, XGA and SXGA analog RGB signals input to the HD15 input connector.

Accepts DVI-D (digital) input signals *1

Adopting the scan converter allows this monitor to detect VGA, SVGA, XGA and SXGA digital computer signals input to the DVI input connector.

The number of the DVI input connectors can be increased by installing the optional input adaptor into the optional input port.

To view more than SXGA signals when the DVI input is selected, use the cable within 3 m (118 1/8 inches) in length.

*1 For acceptable formats, see “About the preset signal” on page 79.

Optional port

Two optional input adaptors can be installed. The composite, Y/C, component, analog RGB, SDI or DVID signal can be input depending on the input connectors of the board to be used. SDI supports not only HD-SDI and SD-SDI, but also 3G-SDI, which transmits twice as much data as HD-SDI with a Single-link.

Multi-format *2

NTSC or PAL color system or DTV format, such as 720P, 1080i, etc. can be selected automatically.

*2 For acceptable formats, see “Available signal formats” on page 78.

External sync input

The unit can be operated on the sync signal supplied from an external sync generator.

Functions

APA (Auto Pixel Alignment) function

You can display pictures from the HD15 input connector in the appropriate picture by simply pressing the APA key.

Automatic termination (connector with W-mark only)

The input connector is terminated internally at 75 ohms when nothing has been connected to the output connector. If a cable is connected to the output connector, the internal terminal is automatically released and the signals input to the input connector are output to the output connector (loop-through).

Select color temperature and gamma mode

You can select the color temperature from among three (HIGH, LOW, LOW2) settings and gamma mode from between two settings (2.2, DICOM). You can also adjust the color temperature to the appropriate setting in "USER".

Two-display

Two kinds of input signals are put on the monitor.

For more information, see MULTI DISPLAY of "MULTI DISPLAY SETTING" on page 70.

Color space feature

You can select ITU-R BT.709 for the color space settings.

Aspect setting

You can set the monitor to 4:3 or 16:9 display mode according to the input signal.

Scan function

You can select the display from among “NORMAL”, “OVER”, “FULL” and “NATIVE” except the HD15 and DVI input signals.

Select language display

You can select your language for the display from seven languages - English, French, German, Spanish, Italian, Japanese and Chinese.

Power saving function

The monitor enters into power saving mode to reduce the power consumption when no signal is input.

Key inhibit function

You can inhibit the key to prevent missing an operation.

User memory function

You can save the 20 picture settings with the name. The user memory data can be saved or loaded between the monitor and the equipment (PC, etc.) connected in serial remote mode.

Two kinds of ground terminals

Two kinds of ground terminals are built into the monitor to equalize the electric potential.

External remote function

The input signal is selected or various items are adjusted by using the serial (Ethernet) remote function. You can connect this unit to the monitor via Ethernet (10BASE-T/100BASE-TX) and control it remotely over the network.

For more information, see SERIAL REMOTE in the REMOTE menu on page 73.

Other

Optional stand

It is more convenient to install the monitor on a desk by using the optional stand (SU-560).

Location and Function of Parts and Controls

Front Panel

Diagram of a tablet device with labeled ports and connectors, showing numbered labels from 1 to 12.

① Tally lamp

You can check the status of the monitor by the color of the tally lamp.

The tally lamp lights in green according to the setting of PARALLEL REMOTE in the REMOTE menu.

② Power indicator

When the power is turned on, the power indicator lights in green.

③ (key inhibit) indicator

Lights in green when KEY INHIBIT in the KEY INHIBIT menu is set to ON.

4 CONTROL button

Press to display the buttons on the front panel. Press again to clear the display.

⑤ CONTRAST buttons

Adjusts the picture contrast.

Press the + button to make the contrast higher or the - button to make it lower.

⑥ PHASE buttons

Press the + button to make the skin tones greenish or the - button to make them purplish.

⑦ CHROMA buttons

Adjusts the color intensity.

Press the + button to increase the color intensity or the - button to decrease it.

⑧ BRIGHT (brightness) buttons

Adjusts the picture brightness.

Press the + button to increase the brightness or the - button to decrease it.

⑨ Menu operation buttons

Displays or sets the on-screen menu.

Press to display the on-screen menu.

Press again to clear the menu.

+/- buttons

Press to select the items and setting values.

ENTER button

Press to confirm a selected item on the menu.

When the menu is not displayed and the button is pressed, the distinguished signal format is displayed.

RETURN button

When the menu is displayed and the button is pressed, the value of an item is reset to the previous value.

When the menu is not displayed and the button is pressed, the function selected in FUNCTION BUTTON SETTING of the USER CONFIG menu is displayed on the side of the F1 to F4 button. Also, when the fan stops, this button blinks.

10 Input select buttons

Press the button to monitor the signal input to each connector.

A-1, A-2, B-1 and B-2 buttons are used when an optional input adaptor has been installed in the option port.

COMPOSITE button: to monitor the signal through the COMPOSITE IN connector

Y/C button: to monitor the signal through the Y/C IN connector

RGB button: to monitor the RGB signal through the connectors for the R/G/B signal input

COMPONENT button: to monitor the component signal through the connectors for Y/PB/PR signal input

A-1 button: to monitor the signal from connector 1 of the input adaptor installed in the option port A or R/G/B signal from BKM-229X/BKM-256DD installed in the option port A

A-2 button: to monitor the signal from connector 2 of the input adaptor installed in the option port A or Y/PB/PR signal from BKM-229X/BKM-256DD installed in the option port A

B-1 button: to monitor the signal from connector 1 of the input adaptor installed in the option port B or R/G/B signal from BKM-229X/BKM-256DD installed in the option port B

B-2 button: to monitor the signal from connector 2 of the input adaptor installed in the option port B or Y/PB/PR signal from BKM-229X/BKM-256DD installed in the option port B

HD15 button: to monitor the signal through the HD15 input connector

DVI button: to monitor the signal through the DVI-D input connector

⑪ Function buttons

You can turn the assigned function on or off.

The factory setting is as follows;

F1 button: EXT SYNC

F2 button: SCAN

F3 button: ASPECT

F4 button: MULTI DISPLAY

You can assign the function from among SCAN, ASPECT, EXT SYNC, BLUE ONLY, MONO, MULTI DISPLAY, APA, I/P MODE and MIRROR IMAGE in FUNCTION BUTTON SETTING of the USER CONFIG menu (see page 71).

For details of the function assigned to the function button, see page 71.

⑫ USER MEM (user memory) button

Press to load the picture settings saved in the USER MEMORY menu (on page 74).

Input Signals and Adjustable/Setting Items

○ : Adjustable/can be set ×: Not adjustable/cannot be set

*1 Adjustment of SUB CONTROL is the same.

*2 When a component signal (480/60I or 480/60P) is input and the COMPONENT LEVEL is set to SMPTE, this can be switchable.

*3 When a BKM-227W is installed, the number of the input connector is increased.

*4 When a BKM-229X is installed, the number of the input connector is increased.

*5 When a BKM-220D, BKM-243HSM or BKM-250TGM is installed, the signal can be input.

*6 When a BKM-243HSM or BKM-250TGM is installed, the signal can be input.

*7 Only the interlace signal is input.

*8 The signal can operate with PRESET 2 to 6 (see page 79).

*9 For details on the input signal available for the multi display, see "For the multi display" (page 81).

*10 The signal cannot operate with PRESET 7 and 8 (see page 79).

*11 The signal can only operate with PRESET 1 (see page 79).

*12 The signal can only operate with PRESET 6 (see page 79).

*13 When a BKM-256DD is installed, the number of the input connector is increased.

*14 When a BKM-250TGM is installed, the signal can be input.

Rear/Bottom Panel

Diagram showing labeled components of a computer monitor front panel with numbered parts and connectors.

① /± (Equipotential/Function Earth) terminal

(equipotential) terminal Connects the equipotential plug. 1/2 (function earth) terminal Connects the earth cable.

② COMPOSITE IN connector (BNC)

Input connector for composite signals.

③ Y/C IN connector (4-pin mini-DIN)

Input connector for Y/C signals.

④ G/Y IN connector (BNC)

Input connector for G of RGB signals and component Y (luminance) signals.

⑤ B/P B IN connector (BNC)

Input connector for B of RGB signals and Pb (blue color difference) of component signals.

⑥ R/P R IN connector (BNC)

Input connector for R of RGB signals and PR (red color difference) of component signals.

⑦ EXT SYNC IN (external sync input) connector (BNC)

When this unit operates on an external sync signal, connect the reference signal from a sync generator to this connector.

To use the external sync signal, press the function button that EXT SYNC is assigned (F1 button at the factory setting).

Note

When inputting a video signal with the jitters, etc. the picture may be disturbed. We recommend using the TBC (time base corrector).

8 Loop-through output connectors

Outputs the signals input to the input connectors (② to

⑦). Connect to the analog input (composite, Y/C, analog component, analog RGB or external sync) of equipment, according to the input signal.

When a cable is connected to one of these connectors, the 75-ohm termination of the corresponding input is automatically released, and the signal input to the input connector is output.

⑨ DC 5V/24V IN connector

Connect the DC connector of the supplied AC adaptor.

⑩ Optional input port

An optional input adaptor can be installed according to your system configuration (see page 60).

The left side port is A and the right side port is B. Press the A-1, A-2, B-1 or B-2 button to select the signal.

⑪ / (power) switch

The power is turned on or off.

The monitor is turned on by pressing side Ⓤ

12 PARALLEL REMOTE connector (modular connector, 8-pin)

Forms a parallel switch and controls the monitor externally.

When the unit is shipped from the factory, a connector cover is attached to this connector. Remove it before using the connector.

For removing the connector cover, see page 60.

For details on the pin assignment and factory setting function assigned to each pin, see page 78.

CAUTION

For safety, do not connect the connector for peripheral device wiring that might have excessive voltage to this port. Follow the instructions for this port.

13 SERIAL REMOTE connector (RJ-45)

Connect to the network by using a 10BASE-T/100BASE-TX LAN cable (shielded type, optional).

When the unit is shipped from the factory, a connector cover is attached to this connector. Remove it before using the connector.

For removing the connector cover, see page 60.

For details on this connector, refer to the Interface Manual for Programmers (saved in the supplied CD-ROM, Japanese and English only.)

CAUTION

  • When an optional LAN cable is connected, use a shield type cable to prevent miss-operation due to noises.
  • For safety, do not connect the connector for peripheral device wiring that might have excessive voltage to this port. Follow the instructions for this port.
  • The connection speed may be affected by the network system. This unit does not guarantee the communication speed or quality of 10BASE-T/100BASE-TX.

14 SERIAL REMOTE RS-232C connector (D-sub 9-pin, female)

Connect to the RS-232C control connector on external equipment connected to the monitor. The monitor can be operated according to control commands sent from external equipment connected to it.

For details on the pin assignment and factory setting function assigned to each pin, see page 78.

For details on this connector, refer to the Interface Manual for Programmers (saved in the supplied CD-ROM, Japanese and English only.)

15 DVI-D input connector (DVI-D)

Inputs DVI Rev.1.0 applicable digital RGB signal. To view the signals of the SXGA and higher resolution when the DVI input is selected, use the cable within 3 m (118 1/8 inches) in length.

16 HD15 input connector (D-sub 15 pin, female)

Inputs an analog RGB video signal (0.7 Vp-p, positive polarity) and sync signal.

The Plug & Play function corresponds to DDC2B.

Connecting the AC Power Cord

Connect the supplied AC power cord as illustrated. Two kinds of AC plug holders are supplied with this unit. Use the AC plug holder that fits the AC power cord most securely.

1 Plug the AC power cord into the AC IN socket on the AC adaptor. Then, attach the AC plug holder to the AC power cord.

AC IN socket AC power cord AC plug holder (Supplied)

2 Slide the AC plug holder over the cord until it locks.

Line drawing of a plug inserted into a socket (no text or symbols).

3 Insert the DC IN connector into the DC 5V/24V IN connector on the bottom of this unit until it locks.

Line drawing of a monitor setup with an inset showing a close-up of the screen (no text or symbols present).

To remove the AC power cord

First, pull out the AC plug holder while pressing the lock levers.

Next, pull out the DC IN connector from the DC 5V/24V IN connector while pressing the lock lever.

Installing the Input Adaptor

Before installing the input adaptor, disconnect the power cord.

1 Remove the panel of the optional input port.

Technical line drawing of a mechanical assembly with screwdriver and adjustment tool (no text or symbols)

2 Insert the input adaptor into the port.

Technical line drawing of a mechanical assembly with multiple ports and connectors (no text or symbols)

3 Tighten the screws.

Line drawing of a device rear panel with screwdriver inserted (no text or symbols)

Removing the Connector Cover

When the unit is shipped from the factory, a connector cover is attached to the PARALLEL REMOTE connector and the SERIAL REMOTE connector (RJ-45).

To use the connector, remove the connector cover as follows.

Before removing the connector cover, disconnect the power cord.

Connector cover

1 Remove the screw of the connector cover.

2 Remove the connector cover.

Save the screw and cover, so that you can reattach the cover if necessary.

Caution

These connectors are designed to allow direct contact with conductive circuits. Weak voltage may be present because of a failure in this unit. To prevent patients from touching these connectors accidentally, attach the connector covers when the connectors are not being used to connect to other devices.

Selecting the Default Settings

When you turn on the unit for the first time after purchasing it, select the area where you intend to use this unit from among the options.

The default setting values for each areaWorld map with numbered regions highlighting Asia, Africa, and parts of South America

COLOR TEMPCOMPONENT LEVELNTSC SETUP
1NORTH AMERICALOW BETA7.5 7.5
2LATIN AMERICAARGENTINA LOW SMPTE 0
PAL&PAL-N AREAPARAGUAY LOW SMPTE 0
URUGUAY LOW SMPTE 0
NTSC&PAL-M AREAOTHER AREA LOW BETA7.5 7.5
3AFRICA AUSTRALASIA EUROPE MIDDLE-EASTLOW SMPTE 0
4ASIA EXCEPT JAPANNTSC AREA LOW BETA7.5 7.5
PAL AREA LOW SMPTE 0
5JAPAN HIGH SMPTE 0

1 2 3~4

1 Turn on the unit with the power switch on the bottom panel.

The SELECT SETTING screen appears.

SELECT SETTING NORTH AMERICA LATIN AMERICA AFRICA AUSTRALASI ASIA EXCEPT JAPAN JAPAN ①North America ②Latin America ③Africa Australia/New Zealand, Europe, Middle East, Russia ④Asia Except Japan ⑤Japan

2 Press the CONTROL button.

3 Press the + or - button to select the area where you intend to use the unit and press the ENTER button.

If you select either ①, ③ or ⑤

The confirmation screen is displayed. Confirm the selected area. When the setting is wrong, press the RETURN button to return to the previous screen.

SELECT THIS AREA?

NORTH AMERICA

[ENTER]YES

[RETURN]NO

If you select either ② or ④

One of the following screens appears. Press the + or - button to narrow the area further and then press the ENTER button.

The confirmation screen is displayed. Confirm the selected area. When the setting is wrong, press the RETURN button to return to the previous screen.

②If LATIN AMERICA is selected:

LATIN AMERICA PAL&PAL-N AREA ARGENTINA PARAGUAY URUGUAY NTSC&PAL-M AREA OTHER AREA PAL&PAL-N area Argentina Paraguay Uruguay NTSC&PAL-M area Other area

④If ASIA EXCEPT JAPAN is selected:

Customers who will use this unit in the shaded areas shown in the map below should select NTSC AREA.

Other customers should select PAL AREA.

Outline map of East Asia and surrounding countries, highlighting the region in central Asia (no text or labels)

ASIA EXCEPT JAPAN NTSC AREA NTSC area PAL AREA PAL area

4 Press the ENTER button.

The SELECT SETTING screen disappears and the menu item settings suitable for the selected area are applied.

Note

When you have selected the wrong area, set the following items using the menu.

• COLOR TEMP (on page 67) • COMPONENT LEVEL (on page 69) • NTSC SETUP (on page 69)

See “The default setting values for each area” (page 61) on the setting value.

Selecting the Menu Language

You can select one of seven languages (English, French, German, Spanish, Italian, Japanese, Chinese) for displaying the menu and other on-screen displays.

“ENGLISH (English)” is selected in the default setting. The current settings are displayed in place of the ■ marks on the illustrations of the menu screen.

1 2 3 4~6

1 Turn on the unit. 2 Press the CONTROL button.

The operation buttons are displayed.

3 Press the MENU button.

The menu appears.

The menu presently selected is shown in yellow.

STATUS 1/2 FORMAT COLOR TEMP COMPONENT LEVEL NTSC SETUP SCAN MODE POWER SAVING

4 Press the + or - button to select SYSTEM SETTING of the USER CONFIG (User Configuration) menu, then press the ENTER button.

The setting items (icons) in the selected menu are displayed in yellow.

USER CONFIG - SYSTEM SETTING MATRIX: □□□□ COMPONENT LEVEL: ■■■■ NTSC SETUP: ■ GAMMA: ■■■ FORMAT DISPLAY: ■■■■ LANGUAGE: ENGLISH POWER SAVING: ■■■ I/P MODE: ■■■■■■■ BACKGROUND: ■

5 Press the + or - button to select "LANGUAGE," then press the ENTER button.

The selected item is displayed in yellow.

USER CONFIG - SYSTEM SETTING MATRIX: ■■■ COMPONENT LEVEL: ■■■■ NTSC SETUP: ■ GAMMA: ■■■ FORMAT DISPLAY: ■■■■ LANGUAGE: ENGLISH POWER SAVING: ■■■ I/P MODE: ■■■■■■■ BACKGROUND: ■

6 Press the + or - button to select a language, then press the ENTER button.

The menu changes to the selected language.

USER CONFIG - SYSTEM SETTING MATRIX: ■■ COMPONENT LEVEL: ■■■■■ NTSC SETUP: ■ GAMMA: ■■■ FORMAT DISPLAY: ■■ LANGUAGE: ENGLISH POWER SAVING: ■■ I/P MODE: ■■■■■■■ BACKGROUND: ■

To clear the menu

Press the MENU button.

The menu disappears automatically if a button is not pressed for one minute.

Using the Menu

The unit is equipped with an on-screen menu for making various adjustments and settings such as picture control, input setting, set setting change, etc. You can also change the menu language displayed in the on-screen menu.

To change the menu language, see "Selecting the Menu Language" on page 62.

The current settings are displayed in place of the ■ marks on the illustrations of the menu screen.

1 2 3~5 RETURN button

1 Press the CONTROL button.

The operation buttons are displayed.

2 Press the MENU button.

The menu appears.

The menu presently selected is shown as a yellow button.

STATUS 1/2 FORMAT COLOR TEMP COMPONENT LEVEL NTSC SETUP SCAN MODE POWER SAVING

3 Use the + or - button to select a menu, then press the ENTER button.

The menu icon presently selected is shown in yellow and setting items are displayed.

USER CONFIG - SYSTEM SETTING MATRIX: ■■ COMPONENT LEVEL: ■■■■■■ NTSC SETUP: ■ GAMMA: ■■■ FORMAT DISPLAY: ■■ LANGUAGE: ENGLISH POWER SAVING: ■■ I/P MODE: ■■■■■■■ BACKGROUND: ■

4 Select an item.

Use the + or - button to select the item, then press the ENTER button.

The item to be changed is displayed in yellow.

If the menu consists of multiple pages, press + or - button to go to the desired menu page.

5 Make the setting or adjustment on an item.

When changing the adjustment level:

To increase the number, press the + button.

To decrease the number, press the - button.

Press the ENTER button to confirm the number, then restore the original screen.

When changing the setting:

Press the + or - button to change the setting.

Press the ENTER button to confirm the setting.

When returning the adjustment or setting to the previous value:

Press the RETURN button before pressing the ENTER button.

Notes

  • An item displayed in black cannot be accessed. You can access the item if it is displayed in white.
  • If the key inhibit has been turned on, all items are displayed in black. To change any of the items, turn the key inhibit to OFF first.

For details on the key inhibit, see page 74.

To return the display to the previous screen

Press the RETURN button.

To clear the menu

Press the MENU button.

The menu disappears automatically if a button is not pressed for one minute.

About the memory of the settings

The settings are automatically stored in the monitor memory.

Loading USER MEMORY

You can load the picture settings saved in the USER MEMORY menu (on page 74).

1 2~3

1 Press the USER MEM button.

The USER MEMORY menu appears.

USER MEMORY 1/3 ■DEFAULT . 01 USER01 . 02 USER02 . 03 USER03 . 04 USER04 . 05 USER05 . 06 USER06

2 Select the memory number.

+ or - button: to select the memory number

3 Press the ENTER button.

After loading the picture settings from the selected memory, the menu disappears.

To stop selecting the memory

Press the USER MEM button.

The USER MEMORY menu disappears.

To reset the settings

Select "DEFAULT", then press the ENTER button.

Adjustment Using the Menus

Items

The screen menu of this monitor consists of the following items.

STATUS (the items indicate the current settings.)

For the video input

FORMAT

COLOR TEMP

COMPONENT LEVEL

NTSC SETUP

SCAN MODE

POWER SAVING

Model name and serial number

OPTION A and serial number

OPTION B and serial number

For the DVI/HD15 input

FORMAT

fH

fV

COLOR TEMP

POWER SAVING

Model name and serial number

OPTION A and serial number

OPTION B and serial number

COLOR TEMP/SPACE

COLOR TEMP

MANUAL ADJUSTMENT

COLOR SPACE

USER CONTROL

For the video input

AUTO CHROMA/PHASE

SUB CONTROL

PICTURE CONTROL

INPUT SETTING

For the DVI/HD15 input

SUB CONTROL

PICTURE CONTROL

USER CONFIG

SYSTEM SETTING

MATRIX

COMPONENT LEVEL

NTSC SETUP

GAMMA

FORMAT DISPLAY

LANGUAGE

POWER SAVING

I/P MODE

BACKGROUND

MULTI DISPLAY SETTING

MULTI DISPLAY ENABLE

MULTI DISPLAY

SUB INPUT SELECT

POSITION

FRAME

FUNCTION BUTTON SETTING

F1 BUTTON

F2 BUTTON

F3 BUTTON

F4 BUTTON

COMPUTER DETECT

DVI

HD15

OPTION DVI SETTING *1

EXT 5V(IN)

EXT 5V(OUT)

EDID UPDATE

EDID STATUS

*1 Displayed only when a BKM-256DD is installed.

REMOTE

PARALLEL REMOTE

SERIAL REMOTE

ON KEY INHIBIT

KEY INHIBIT

USER MEMORY

01 to 20

Adjusting and Changing the Settings

STATUS menu

The STATUS menu is used to display the current status of the unit. The following items are displayed:

For the video input

STATUS 1/2 FORMAT COLOR TEMP COMPONENT LEVEL NTSC SETUP SCAN MODE POWER SAVING

STATUS 2/2 LMD-2451MD OPTION A OPTION B BKM-243HS NOT INSTALLED

  • Signal format
  • Color temperature
  • Component level
  • NTSC setup
  • Scan mode
  • Powersaving
  • Model name and serial number • OPTION A and serial number • OPTION B and serial number

For the DVI/HD15 input

STATUS 1/2 FORMAT fH fV COLOR TEMP POWER SAVING

STATUS 2/2 LMD-2451MD OPTION A OPTION B BKM-243HS NOT INSTALLED

  • Signal format • fH • fV • Color temperature
  • Powersaving
  • Model name and serial number • OPTION A and serial number • OPTION B and serial number

COLOR TEMP/SPACE menu

The COLOR TEMP/SPACE menu is used for adjusting the picture white balance or color space.

You need to use the measurement instrument to adjust the white balance.

Recommended: Konica Minolta color analyzer CA-210

COLOR TEMP/SPACE COLOR TEMP: ■■■■■■■ MANUAL ADJUSTMENT: ADJUST GAIN: ADJUST BIAS: COPY FROM: ■■■ COLOR SPACE: ■

Submenu Setting

COLOR TEMP Selects the color temperature fromamong “HIGH”, “LOW” or“USER” and “LOW2” setting.
MANUALADJUSTMENTIf you set the COLOR TEMP toUSER setting, the item displayed ischanged from black to white, whichmeans you can adjust the colortemperature.The set values are memorized.ADJUST GAIN: Adjusts thecolor balance (GAIN).ADJUST BIAS: Adjusts thecolor balance (BIAS).COPY FROM: If you select“HIGH”, “LOW” or“LOW2”, the white balancedata for the selected colortemperature will be copiedin the “USER” setting.
COLOR SPACE Selects the color space either ITU-709 or OFF. OFF sets the colorspace to the original colorreproduction of the LCD panel.

USER CONTROL menu

The USER CONTROL menu is used for adjusting the picture.

Items that cannot be adjusted depending on the input signal are displayed in black.

For details of input signals and adjustable/setting items, see page 56.

For the video inputUSER CONTROL 1/3 AUTO CHROMA/PHASE AUTO ADJ VALUE: START:

USER CONTROL 2/3 SUB CONTROL CONTRAST: BRIGHTNESS: CHROMA: PHASE: APERTURE: BACKLIGHT:

USER CONTROL 3/3 PICTURE CONTROL ACC: CTI: V SHARPNESS: INPUT SETTING SHIFT H: SHIFT V:

Submenu Setting
AUTO CHROMA/PHASEAdjusts color intensity (CHROMA) and tones (PHASE).• AUTO ADJ VALUE: Selects ON or OFF of the auto adjustment. When you set to OFF, this parameter is reset to the factory setting. When you set to ON, the automatically adjusted value is enabled.• START: The auto adjustment starts when you display the color bar signals (Full/ SMPTE/EIA) on the screen and press the ENTER button. After adjusting the color intensity, press the MENU button to clear the adjustment screen. After the adjustment is done correctly, the AUTO ADJ VALUE is automatically set to ON.

SUB CONTROL Adjusts finely the adjustment range of the button on the front panel for CONTRAST, BRIGHTNESS, CHROMA and PHASE.

- CONTRAST: Adjusts the picture contrast.

• BRIGHTNESS: Adjusts the picture brightness.

- CHROMA: Adjusts color intensity. The higher the setting, the greater the intensity. The lower the setting, the lower the intensity.

- PHASE: Adjusts color tones. The higher the setting, the more greenish the picture. The lower the setting, the more purplish the picture.

- APERTURE: Adjusts the picture sharpness. The higher the setting, the sharper the picture. The lower the setting, the softer the picture.

- BACKLIGHT: Adjusts the backlight. When the setting is changed, the brightness of the backlight is changed.

PICTURE CONTROL Adjusts the picture.

- ACC (Auto Color Control): Sets ACC circuit on or off. To check the fine adjustment, select OFF. Normally select ON.

- CTI (Chroma Transient Improvement): When a low color resolution signal is input, a crisp image can be displayed. When the setting is higher, the picture becomes even more crisp.

- V SHARPNESS: A crisp image can be displayed. When the setting is higher, the picture becomes even more crisp.

INPUT SETTING • SHIFT H: Adjusts the position of the picture. As the setting increases, the picture moves to the right, and as the setting decreases, the picture moves to the left.

- SHIFT V: Adjusts the position of the picture. As the setting increases, the picture moves up, and as the setting decreases, the picture moves down.

For the DVI/HD15 input

* The 1/3 menu cannot be adjusted.

USER CONTROL 2/3 SUB CONTROL CONTRAST: ■ BRIGHTNESS: ■ CHROMA: ■ PHASE: ■ APERTURE: ■ BACKLIGHT: ■

USER CONTROL 3/3 PICTURE CONTROL SIZE H: ■■ SIZE V: ■■ SHIFT H: ■■ SHIFT V: ■■ DOT PHASE: ■■ PITCH: ■■ RESOLUTION: ■■ RESET

SUB CONTROL Adjusts finely the adjustment range of the button on the front panel for CONTRAST, BRIGHTNESS, CHROMA and PHASE.

- CONTRAST: Adjusts the picture contrast.

• BRIGHTNESS: Adjusts the picture brightness.

- CHROMA: Adjusts color intensity. The higher the setting, the greater the intensity. The lower the setting, the lower the intensity.

- PHASE: Adjusts color tones. The higher the setting, the more greenish the picture. The lower the setting, the more purplish the picture.

- APERTURE: Adjusts the picture sharpness. The higher the setting, the sharper the picture. The lower the setting, the softer the picture.

- BACKLIGHT: Adjusts the backlight. When the setting is changed, the brightness of the backlight is changed.

PICTURE CONTROL Adjusts to monitor the picture more clearly.

- SIZE H: Adjusts the horizontal size of the picture. The higher the setting, the larger the horizontal size of the picture. The lower the setting, the smaller the horizontal size of the picture.

- SIZE V: Adjusts the vertical size of the picture. The higher the setting, the larger the vertical size of the picture. The lower the setting, the smaller the vertical size of the picture.

- SHIFT H: Adjusts the position of the picture. As the setting increases, the picture moves to the right, and as the setting decreases, the picture moves to the left.

- SHIFT V: Adjusts the position of the picture. As the setting increases, the picture moves up, and as the setting decreases, the picture moves down.

- DOT PHASE: Adjusts the dot phase. Adjust the picture further for a finer picture after APA (page 71) is adjusted.

- PITCH: Adjusts the horizontal size of the picture with the left side of the picture fixed. The higher the setting, the larger the width of the picture. The lower the setting, the narrower the width of the picture.

- RESOLUTION: Sets when the computer signal is input and it is difficult to understand the signal type such as XGA/60 or WXGA/60 - XGA: Displayed as XGA signal. - WXGA: Displayed as WXGA signal.

- RESET: Resets the value of SIZE H, SIZE V, SHIFT H, SHIFT V, DOT PHASE and PITCH to the factory preset value.

SONY LMD-2451MD - Submenu Setting - 1

USER CONFIG menu

The USER CONFIG menu is used for setting the system, multi display, function button, computer detect and option DVI.

USER CONFIG SYSTEM SETTING: MULTI DISPLAY SETTING: FUNCTION BUTTON SETTING: COMPUTER DETECT: OPTION DVI SETTING:

SYSTEM SETTING

USER CONFIG - SYSTEM SETTING MATRIX: COMPONENT LEVEL: NTSC SETUP: GAMMA: FORMAT DISPLAY: LANGUAGE: ENGLISH POWER SAVING: I/P MODE: BACKGROUND:

Submenu Setting

MATRIX Applied to 480/60I or 480/60P signal. Select 601 or 709.
COMPONENT LEVEL Selects the component level from among three modes.SMPTE: for 100/0/100/0 signalBETA0: for 100/0/75/0 signalBETA7.5: for 100/7.5/75/7.5 signal
NTSC SETUP Selects the NTSC setup level from two modes.The 7.5 setup level is used mainly in North America. The 0 setup level is used mainly in Japan.
GAMMA Selects the appropriate gamma mode from between two settings (“2.2”, “DICOM”).When “2.2” is selected, the setting is roughly same as the gamma mode of the CRT.
FORMAT DISPLAY Selects the display mode of the signal format and scan mode.ON: The format is always displayed.OFF: The display is hidden.AUTO: The format is displayed for about 10 seconds when the input of the signal starts.

Submenu Setting

LANGUAGE Selects the menu or message language from among seven languages.
• ENGLISH: English
• FRANÇAIS: French
• DEUTSCH: German
• ESPAÑOL: Spanish
• ITALIANO: Italian
• :日本語ese
• :Chinese
POWER SAVING Sets the power saving mode on or off. When you set to ON, the monitor goes into power saving mode if no signal is input for about one minute.
I/P MODE (picture delay minimum)Selects to set the delay by the picture processing to the minimum level when the interlace signal is input.
• INTER-FIELD *1: Mode for giving precedence to the picture quality. Performs interpolation depending on the movement of the images between the fields. It takes longer than “FIELD MERGE” or “LINE DOUBLER” for processing the picture. “INTER-FIELD” is the factory setting.
• FIELD MERGE *2: The processing time is shorter. Combines the lines in the odd fields and even fields alternately regardless of the movement of images. Suitable for viewing still images.
• LINE DOUBLER: The processing time is shorter. Performs interpolation by repeating each line in the data receiving sequence regardless of the field. As the line flicker is displayed in this mode, it is available for checking the line flicker of the telop work and so on.
*1 When MULTI DISPLAY ENABLE is set to ON, INTERFIELD cannot be selected.
*2 When MULTI DISPLAY is set to SIDE BY SIDE, FIELD MERGE cannot be selected.
BACKGROUND Sets the brightness of the black barsappearing in the upper and lowerpositions of the screen, or on thesides of the screen.
• OFF: Displays a darker bar (black).
• ON: Displays a brighter bar (gray).

MULTI DISPLAY SETTING

USER CONFIG - MULTI DISPLAY SETTING MULTI DISPLAY ENABLE: MULTI DISPLAY: SUB INPUT SELECT: POSITION: FRAME:

Submenu Setting

MULTI DISPLAY ENABLESelects ON to display the multi display and OFF not to display.

Notes

- When the frame frequency of the main display is different from that of the sub display, the picture may be disturbed. When no signal is input to the main display, the picture may not be displayed correctly.

- When you set SUB INPUT SELECT to OFF, MULTI DISPLAY ENABLE is set to OFF automatically.

- When MULTI DISPLAY ENABLE is set to ON, APA (page 71) is not available.

MULTI DISPLAY • POP: The sub display is put by the side of the main display. Either NORMAL or OVER can be selected for the scan mode in the main display.

- SIDE BY SIDE: The main display is put in the left side of the display and the sub display is put in the right side of the display. Either NORMAL or FULL can be selected for the scan mode in the main and sub display. The scan mode of the main and sub display will change at the same time. You cannot set a different scan mode for each display.

To switch the scan mode, press the function button assigned to change the scan mode. See “FUNCTION BUTTON SETTING” (page 71) and “About the function assigned to the function button” (page 71).

Note

When MULTI DISPLAY is set to SIDE BY SIDE, CTI (page 68) is not available.

Submenu Setting

SUB INPUTSets the input signal of the sub display.
SELECTYou can select from amongCOMPOSITE, Y/C, RGB,COMPONENT, DVI, HD15, OPTIONA-1, OPTION A-2, OPTION B-1,OPTION B-2, VIDEO WAVE and OFF.

Notes

  • The multi display with COMPOSITE and Y/C, RGB and COMPONENT, HD15 and DVI, OPTION A-1 and OPTION A-2, and OPTION B-1 and OPTION B-2 is not displayed.
  • When you set SUB INPUT SELECT to OFF, MULTI DISPLAY ENABLE is set to OFF.
  • The input signal formats available for HD15 and DVI are limited. See “For the multi display” (page 81).

POSITION Sets the position of the sub display.

• 1: Top • 2: Bottom

FRAME Sets the position of the main display when POP is selected in MULTI DISPLAY.

  • RIGHT: The main display is put by the right side of the sub display.
  • LEFT: The main display is put by the left side of the sub display.

FUNCTION BUTTON SETTING

USER CONFIG — FUNCTION BUTTON SETTING F1 BUTTON: ■■■■ F2 BUTTON: ■■■■ F3 BUTTON: ■■■■ F4 BUTTON: ■■■■

Submenu Setting

F1 BUTTON to F4 BUTTONAssigns the function to the function buttons of the front panel and turns the function on or off.You can assign the function from among SCAN, ASPECT, EXT SYNC, BLUE ONLY, MONO, MULTI DISPLAY, APA, I/P MODE and MIRROR IMAGE.Factory setting• F1 button:EXT SYNC• F2 button:SCAN• F3 button:ASPECT• F4 button:MULTI DISPLAY

About the function assigned to the function button

SCAN

Press to change the scan size of the picture. Press to switch between NORMAL scan (0% scan), OVER scan (20% over scan), FULL and NATIVE (see “Scan mode image” on page 72). NATIVE is effective only when 1080i, 1080P or 720P signal is input. 1080P can be selected when BKM-250TGM is installed.

The scan mode of the picture can also be changed when MULTI DISPLAY ENABLE is set to ON. Selectable scan modes vary depending on the settings in MULTI DISPLAY (page 70). When FULL is selected as the SIDE BY SIDE multi display mode, the size of the picture is enlarged while keeping the aspect ratio the same. In this case, the left and right edges of the image are cut off.

graph LR A["Rectangular Block with two circles"] --> B["Square divided into two equal circles"]

ASPECT

Press to set the aspect ratio of the picture, 4:3 or 16:9.

EXT SYNC (external sync)

Press to operate the unit on an external sync signal through the EXT SYNC IN connector. EXT SYNC works when the component/RGB signals are input.

BLUE ONLY

Press the assigned button to eliminate the red and green signals. Only blue signal is displayed as an apparent monochrome picture on the screen. This facilitates “chroma” and “phase” adjustments and observation of VCR noise.

MONO

Press the assigned button to display a monochrome picture. When the button is pressed again, the monitor switches automatically to color mode.

MULTI DISPLAY

Press the assigned button to display the multi display. Set the multi display setting in the MULTI DISPLAY SETTING menu (see page 70).

APA (Auto Pixel Alignment)

Press to adjust the picture automatically to maximum clarity for the signal input to the HD15 input connector. For finer adjustment according to the input signal, see “DOT PHASE” on page 69.

When the menu screen or the multi display is displayed, APA does not function.

Note

If the APA operation does not finish correctly depending on the input signal, adjust DOT PHASE (page 69).

I/P MODE

Press the button to set the delay by the picture processing to the minimum level when interlace signal is input. The mode switches in the sequence INTERFIELD → FIELD MERGE → LINE DOUBLER with every press of the button (see “I/P MODE” on page 70).

MIRROR IMAGE

Press the assigned button to flip and display the video signal horizontally. This function is not available for the PRESET 1 signal and the multi display.

F → A

Scan mode image

Input
NORMAL (zeroscan)4:3 1600 × 120016:9 1920 × 1080
OVER (20% over scan)4 1600 × 120016 1920 × 1080
FULL-16 1920 × 1200
NATIVE (1080i, 1080P)-1920 × 1080
1080P is effective only when BKM-250TGM is installed.
NATIVE (720P)-1280 × 720

COMPUTER DETECT

USER CONFIG- COMPUTER DETECT DVI: HD15:

Submenu Setting

COMPUTER DETECTThe appropriate preset memory is set for the signal from DVI and HD15 input connector. Select “PRESET1” for the standard computer signal. Select “PRESET2” to “PRESET8” when the computer signal is not standard (on page 79). The preset memory is set for each input connector of DVI and HD15.

Note

"PRESET7" and "PRESET8" will only be displayed when "DVI" is selected.

OPTION DVI SETTING

* These settings are displayed only when a BKM-256DD is installed.

USER CONFIG - OPTION DVI SETTING EXT 5V(IN): ■■ EXT 5V(OUT): ■■ EDID UPDATE: ■■■■■■ EDID STATUS: ■■■■

Submenu Setting

EXT 5V(IN) Selects ON to output external 5 Vpower from the DVI input connectors and OFF not to output.
EXT 5V(OUT) Selects ON to output external 5 Vpower from the DVI output connectors and OFF not to output.
EDID UPDATE Downloads the EDID informationfrom the main unit (the monitor) to the BKM-256DD. Select “START,” and then press the ENTER button to start downloading the EDID information automatically. During download, “EDID UPDATING...” is displayed and the CONTROL button cannot be operated. When download finishes correctly, “COMPLETE!” is displayed. When a fault occurs, “ERROR” is displayed. Press the RETURN button to display the on-screen menu.
EDID STATUS The information downloaded to the BKM-256DD from the EDID of the main unit (the monitor) is displayed.MODEL: Model name of the monitorSER.: Serial number of the monitor

SONY LMD-2451MD - OPTION DVI SETTING - 2

REMOTE menu

REMOTE PARALLEL REMOTE: SERIAL REMOTE: MONITOR:

Submenu Setting

PARALLEL REMOTESelects the PARALLEL REMOTE connector pins for which you want to change the function.You can assign various functions to pins 1 to 4 and pins 6 to 8. The following lists the functions you can assign to the pins.---- ("---": No function is assigned.)COMPOSITEY/CRGBCOMPONENTDVIHD15OPTION A-1OPTION A-2OPTION B-1OPTION B-2OVERSCANFULLNORMALNATIVE4:316:9TALLY GEXT SYNCBLUE ONLYMONOMIRROR IMAGENoteIf you use the PARALLEL REMOTE function, you need to connect cables. For more details, see page 78.
SERIAL REMOTESelects the mode to be used.OFF: SERIAL REMOTE does not function.RS-232C: The monitor is controlled by the command of RS-232C.ETHERNET: The monitor is controlled by the command of Ethernet.

MONITOR Set the monitor setting.

IP ADDRESS: Sets the IP address.

SUBNET MASK: Sets the subnet mask.

(255.255.255.000)

DEFAULT GATEWAY: Sets the default gateway on or off.

ADDRESS: Sets the default gateway.

CANCEL: Selects to cancel the setting.

CONFIRM: Selects to save the setting.

on KEY INHIBIT menu

KEY INHIBIT KEY INHIBIT: ■■

You can lock the setting so that they cannot be changed by an unauthorized user.

Select OFF or ON.

If you set to ON, all items are displayed in black, indicating the items are locked.

USER MEMORY menu

USER MEMORY 1/3 ■01 USER01 · 02 USER02 · 03 USER03 · 04 USER04 · 05 USER05 · 06 USER06 · 07 USER07 · 08 USER08

USER MEMORY 2/3 ■09 USER09 · 10 USER10 · 11 USER11 · 12 USER12 · 13 USER13 · 14 USER14 · 15 USER15 · 16 USER16

USER MEMORY 3/3 ■17 USER17 · 18 USER18 · 19 USER19 · 20 USER20

01 to 20 You can save the setting of the following functions.

  • CONTRAST • BRIGHTNESS • CHROMA
  • PHASE · S C A N
  • ASPECT

COLOR TEMP/SPACE menu

  • COLOR TEMP
  • ADJUST GAIN
  • ADJUST BIAS • COLOR SPACE

USER CONTROL menu

• APERTURE SYSTEM SETTING menu • GAMMA - I/P MODE

Saving the user memory

You can save the 20 picture settings with a name. To load the picture in the saved setting, see "Loading USER MEMORY" on page 65.

To save the picture setting

1 Press the + or - button to select the memory number in the USER MEMORY menu, then press the ENTER button.

The USER MEMORY setting menu appears.

USER MEMORY 1/3 01 USER01 ■SAVE: -NAME:

2 Select "SAVE", then press the ENTER button.

The menu for confirming the memory appears.

SAVE TO USER MEMORY 01 ? [ENTER] YES [RETURN] NO

3 Press the ENTER button.

The current picture settings are saved and the USER MEMORY setting menu appears.

To close the menu without saving the setting

Press the RETURN button.

The USER MEMORY setting menu appears.

To change the name

1 Press the + or - button to select the memory number in the USER MEMORY menu, then press the ENTER button.

The USER MEMORY setting menu appears.

USER MEMORY 1/3 01 USER01 ■SAVE: •NAME:

2 Press the – button to select “NAME”, then press the ENTER button.

The menu for setting the user name appears.

USER MEMORY 1/3 01 USER01 + - CHANGE CHAR. [ENTER] CURSOR [RETURN] CANCEL [USER MEM] SAVE

3 Change the user name.

  • Press the ENTER button to move the cursor to the character position to be changed.
  • Press the + or – button to change the character. Usable characters: “A to Z”, “0 to 9”, “.”, “/”, “,”, “_”, “-”, “(space)” Usable number of characters: Maximum 18 characters.
  • Enter a space to clear the character.
  • When the ENTER button is pressed after changing the character, the character is confirmed and the cursor moves to the following character.

4 Press the USER MEM button.

The settings are saved and the USER MEMORY setting menu appears.

To close the menu without saving the setting

Press the RETURN button.

The USER MEMORY setting menu appears.

Troubleshooting

This section may help you isolate the cause of a problem and as a result, eliminate the need to contact technical support.

  • The display is colored in green or purple → Select the correct input by pressing RGB or COMPONENT button.
  • The unit cannot be operated → The key protection function works. Set the KEY INHIBIT setting to OFF in the KEY INHIBIT menu.
  • The black bars appear at the upper and lower positions of the display → When the signal aspect ratio is different from that of the panel, the black bars appear. This is not a failure of the unit.

Specifications

Picture performance

LCD panel a-Si TFT Active Matrix

Pixel efficiency 99.99%

Viewing angle (panel specification)

89°/89°/89°/89° (typical) (up/down/

left/right, contrast > 10:1)

Scan Normal 0%

Over scan 20%

Efficient picture size

518.4 × 324.0, 613.2 mm (w/h, dia)

(20 1/2 × 12 7/8, 24 1/4 inches)

Resolution H 1,920 dots, V 1,200 lines

Aspect ratio 16:10

Input

Composite input (NTSC/PAL) connector

BNC type (1)

1 Vp-p ± 3 dB sync negative

Y/C input connector

4-pin mini-DIN (1)

Y: 1 Vp-p ± 3 dB sync negative

C: 0.286 Vp-p ± 3 dB (NTSC burst signal level)

0.3 Vp-p ± 3 dB (PAL burst signal level)

RGB/component input connectors

BNC type (3)

RGB input: 0.7 Vp-p ± 3 dB (Sync On Green, 0.3 Vp-p sync negative)

Component input: 0.7 Vp-p ± 3 dB (75% chrominance standard color bar signal)

External synchronized input connector

BNC type (1)

0.3 Vp-p to 4.0 Vp-p ± bipolarity ternary or negative polarity binary

HD15 input connector

D-sub 15-pin (1)

R/G/B: 0.7 Vp-p, sync positive (Sync On Green, 0.3 Vp-p sync negative)

Sync: TTL level (polarity free, H/V separate sync)

Plug & Play function: corresponds to DDC2B

DVI input connector

DVI-D (1)

TMDS single link

Remote input connector

Parallel remote

Modular connector 8-pin (1)

Serial remote

D-sub 9-pin (RS-232C) (1)

RJ-45 modular connector (ETHERNET) (1)

Optional input port

2 ports

Signal format:

H: 15 kHz to 45 kHz

V: 48 Hz to 60 Hz

DC IN connector

DC5V/24V (output impedance 0.05 ohms or less)

Output

Composite output connector

BNC type (1)

Loop-through, with 75 ohms automatic terminal function

Y/C output connector

4-pin mini-DIN (1)

Loop-through, with 75 ohms automatic terminal function

RGB/component output connectors

BNC type (3)

Loop-through, with 75 ohms automatic terminal function

External synchronized output connector

BNC type (1)

Loop-through, with 75 ohms automatic terminal function

General

Power LCD monitor (LMD-2451MD)

DC IN: 24 V 4.5 A 5 V 0.030 A

(Supplied from AC adaptor)

AC Adaptor (Sony, AC-110MD)

AC IN: 100 V-240 V, 50/60 Hz, 1.53 A-0.58 A

DC OUT: 24 V 5.0 A 5 V 0.060 A

Power consumption

Maximum: approx. 125 W (when two BKM-229X are installed)

Operating conditions

Temperature

0°C to 35°C (32°F to 95°F)

Recommended temperature

20°C to 30°C (68°F to 86°F)

Humidity 30% to 85% (no condensation)

Pressure 700 hPa to 1060 hPa

Storage and transport temperature

-20°C to +60°C (-4°F to +140°F)

Storage and transport humidity

0% to 90% (no condensation allowed)

Storage and transport pressure

700 hPa to 1060 hPa

Accessories supplied

AC adaptor (AC-110MD) (1)

AC power cord (1)

AC plug holder (2)

Instructions for Use (1)

CD-ROM (1)

Using the CD-ROM Manual (1)

Quick Reference (1)

When you First Use the Monitor (1)

Service Contact List (1)

European Representative (1)

Optional accessories

SDI 4:2:2 input adaptor BKM-220D

HD/D1-SDI input adaptor BKM-243HSM

NTSC/PAL input adaptor BKM-227W

Analog component input adaptor BKM-229X

3G/HD/SDI input adaptor BKM-250TGM

DVI-D input adaptor BKM-256DD

Monitor stand SU-560

Signal cable SMF-405

Medical Specifications

Protection against electric shock: Class I

Protection against harmful ingress of water: Ordinary

Degree of safety in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide:

Not suitable for use in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide

Mode of operation: Continuous

Design and specifications are subject to change without notice.

Note

Always verify that the unit is operating properly before use. SONY WILL NOT BE LIABLE FOR DAMAGES OF ANY KIND INCLUDING, BUT NOT LIMITED TO, COMPENSATION OR REIMBURSEMENT ON ACCOUNT OF THE LOSS OF PRESENT OR PROSPECTIVE PROFITS DUE TO FAILURE OF THIS UNIT, EITHER DURING THE WARRANTY PERIOD OR AFTER EXPIRATION OF THE WARRANTY, OR FOR ANY OTHER REASON WHATSOEVER.

Pin assignment

PARALLEL REMOTE connector

Modular connector

(8-pin)

SONY LMD-2451MD - PARALLEL REMOTE connector - 1

Pin number Functions
1 Designating Y/C input signal
2 Designating RGB input signal
3 Designating OPTION A-1 input signal
4 Designating OPTION A-2 input signal
5GND
6TallylampON/OFF
7Fullscreen
8Overscan

You can allocate functions using the REMOTE menu (see page 73).

Wiring required to use the Remote Control

Connect the function you want to use with a Remote Control to the Ground (Pin 5).

SERIAL REMOTE (RS-232C) connector

D-sub 9-pin, female

SONY LMD-2451MD - SERIAL REMOTE (RS-232C) connector - 1

Pin numberSignal
1NC
2RX
3TX
4NC
5GND
6NC
7RTS
8CTS
9NC

Available signal formats

The unit is applicable to the following signal formats. For details on the input signal available for HD15, DVI and BKM-256DD, see page 79.

○ : Available - : Not available *1 The frame rate is also compatible with 1/1.001. *2 Component only

Available HD15/DVI/BKM-256DD input signal format

About the preset signal

This unit has a preset memory for signals connected to the HD15 and DVI input connectors, and BKM-256DD. When a preset signal is input, the unit automatically detects the signal type and recalls the data for the signal from the preset memory to adjust it to an optimum picture.

This unit is applicable to the following preset signals.

For the single display

PRESET 1

HD15

VESA DMT

ResolutionDot clock [MHz]fH [kHz]fV [Hz]Sync. polarity
Horizontal Vertical
640 × 480 60 Hz 25.17531.469 59.940 NegativeNegative
800 × 600 56 Hz 36.00035.156 56.250 PositivePositive
800 × 600 60 Hz 40.00037.879 60.317 PositivePositive
800 × 600 72 Hz 50.00048.077 72.188 PositivePositive
800 × 600 75 Hz 49.50046.875 75.000 PositivePositive
800 × 600 85 Hz 56.25053.674 85.061 PositivePositive
1024 × 768 60 Hz 65.00048.363 60.004 NegativeNegative
1024 × 768 70 Hz 75.00056.476 70.069 NegativeNegative
1024 × 768 75 Hz 78.75060.023 75.029 PositivePositive
1024 × 768 85 Hz 94.50068.677 84.997 PositivePositive
1152 × 864 75 Hz 108.00067.500 75.000 PositivePositive
1280 × 960 60 Hz 108.00060.000 60.000 PositivePositive
1280 × 1024 60 Hz 108.00063.981 60.020 PositivePositive

VESA CVT

ResolutionDot clock [MHz]fH [kHz]fV [Hz]Sync. polarity
Horizontal VerticalHorizontal Vertical
640 × 480 60 Hz 23.62529.531 59.780 Positive Negative
800 × 600 60 Hz 35.50036.979 59.837 Positive Negative
1024 × 768 60 Hz 56.00047.297 59.870 Positive Negative
1280 × 960 60 Hz 85.25059.201 59.920 Positive Negative
1360 × 768 50 Hz 69.50039.489 49.922 Negative Positive
1360 × 768 60 Hz 84.62547.649 59.936 Negative Positive
1360 × 768 60 Hz 72.00047.368 59.960 Positive Negative
1920 × 1080 50 Hz 141.37555.572 49.975 Negative Positive
1920 × 1080 60 Hz 138.62566.64759.988Positive Negative
1280 × 1024 60 Hz 91.00063.19459.957Positive Negative
1280 × 768 50 Hz 65.12539.51849.959Negative Positive
1280 × 768 60 Hz 80.12547.69359.992Negative Positive
1280 × 768 75 Hz 102.87560.09174.926Negative Positive
1280 × 768 60 Hz 68.25047.39659.995Positive Negative

Others

ResolutionDot clock [MHz]fH [kHz]fV [Hz]Sync. polarity
Horizontal Vertical
720 × 400 70 Hz 28.32231.469 70.087 Negative Positive
1280 × 800 60 Hz 68.90048.935 59.969 Negative Negative

DVI/BKM-256DD

Range of DVI input signal (available to 1920 x 1080/60 Hz) Vertical frequency: 50.0 Hz to 85.1 Hz

Horizontal frequency: 31.5 kHz to 77.0 kHz

Dot clock: 25.175 MHz to 148.000 MHz

Picture size, phase: automatic discrimination by the DE (Data Enable) signal

PRESET 2

Preset signalfH [kHz]fV [Hz]
HD151514 × 48331.560
1476 × 57631.350
1920 × 108033.7560
1920 × 10802850
DVI/ BKM-256DD1280 × 48331.560
1280 × 57631.350
1920 × 108033.7560
1920 × 10802850
1280 × 72045.060
1280 × 102463.260
1280 × 102464.060

PRESET 3

Preset signalfH [kHz]fV [Hz]
HD15720 × 48331.560
720 × 57631.350
1280 × 72045.060
1280 × 72037.550
DVI/ BKM-256DD720 × 48331.560
720 × 57631.350
1280 × 72045.060
1280 × 72037.550

PRESET 4

Preset signalfH [kHz]fV [Hz]
HD15640 × 48031.560
1024 × 76848.460
1280 × 96060.060
DVI/ BKM-256DD1024 × 768*133.7560
1024 × 76848.460
1280 × 960*133.7560
1280 × 96060.060

*1 Available only for HD-SDI signal (1080/60I)

PRESET 5

Preset signalfH [kHz]fV [Hz]
HD15640 × 480 31.5 60
800 × 600 31.3 50
DVI/ BKM-256DD800 × 600 46.9 75

PRESET 6

Preset signalSignal standards
HD15576/50P ITU-R BT.1358
480/60P SMPTE-293M
1080/50I SMPTE-274M
1035/60ISMPTE-260M/BTA S-001B
1080/60ISMPTE-274M/BTA S-001B
720/60P SMPTE-296M
720/50P SMPTE-296M
DVI/ BKM-256DD576/50P ITU-R BT.1358
480/60P SMPTE-293M
1080/50I SMPTE-274M
1035/60ISMPTE-260M/BTA S-001B
1080/60IsMPTE-274M/BTA S-001B
720/60P SMPTE-296M
720/50P SMPTE-296M

PRESET 7 (Selected using DVI in the menu) *2

Preset signalfH [kHz]fV [Hz]
1422 × 1064 33.7560
712 × 480 15.73460
704 × 572 15.62550

PRESET 8 (Selected using DVI in the menu) *2

Preset signalfH [kHz]fV [Hz]
1280 × 1008 33.7560
712 × 480 15.73460
704 × 572 15.62550

*2 Available for the composite, Y/C, component, RGB or SDI signal

For the multi display

PRESET 1

HD15/DVI/BKM-256DD

VESA DMT

ResolutionDot clock [MHz]fH [kHz]fV [Hz]Sync. polarity
Horizontal VerticalHorizontal Vertical
1280 × 1024 60 Hz 108.000 63.981 60.020 PositivePositive

VESA CVT

ResolutionDot clock [MHz]fH [kHz]fV [Hz]Sync. polarity
HorizontalVertical
1360 × 768 60 Hz84.62547.64959.936NegativePositive
1360 × 768 60 Hz72.00047.36859.960PositiveNegative
1920 × 1080 60 Hz138.62566.64759.988PositiveNegative
1280 × 1024 60 Hz 91.00063.194 59.957Positive Negative
1280 × 768 60 Hz 80.12547.693 59.992Negative Positive
1280 × 768 60 Hz 68.25047.396 59.995Positive Negative

PRESET 2

Preset signalfH [kHz]fV [Hz]
HD151514 × 483 31.560
1476 × 576 31.350
1920 × 1080 33.75 60
1920 × 1080 28 50
DVI/ BKM-256DD1280 × 483 31.560
1280 × 576 31.350
1920 × 1080 33.75 60
1920 × 1080 28 50
1280 × 720 45.060
1280 × 102463.260
1280 × 102464.060

PRESET 3

Preset signalfH [kHz]fV [Hz]
HD15720 × 48331.5 60
720 × 57631.3 50
1280 × 720 45.060
1280 × 720 37.550
DVI/ BKM-256DD720 × 48331.5 60
720 × 57631.3 50
1280 × 720 45.060
1280 × 720 37.550

PRESET 4

Preset signalfH [kHz]fV [Hz]
HD15640 × 48031.5 60
1024 × 76848.4 60
1280 × 96060.0 60
DVI/ BKM-256DD1024 × 768*133.7560
1024 × 76848.4 60
1280 × 960*133.7560
1280 × 96060.0 60

*1 Available only for HD-SDI signal (1080/60I)

PRESET 5

Preset signalfH [kHz]fV [Hz]
HD15640 × 48031.5 60
800 × 60031.3 50
DVI/ BKM-256DD800 × 60046.9 75

PRESET 6

Preset signalSignal standards
HD15576/50P ITUR BT.1358
480/60P SMPTE-293M
1080/50I SMPTE-274M
1035/60ISMPTE-260M/BTA S-001B
1080/60ISMPTE-274M/BTA S-001B
720/60P SMPTE-296M
720/50P SMPTE-296M
DVI/ BKM-256DD576/50P ITUR BT.1358
480/60P SMPTE-293M
1080/50I SMPTE-274M
1035/60ISMPTE-260M/BTA S-001B
1080/60IsMPTE-274M/BTA S-001B
720/60P SMPTE-296M
720/50P SMPTE-296M

PRESET 7 (Selected using DVI in the menu) *2

Preset signalfH [kHz]fV [Hz]
1422 × 1064 33.7560
712 × 480 15.73460
704 × 572 15.62550

PRESET 8 (Selected using DVI in the menu) *2

Preset signalfH [kHz]fV [Hz]
1280 × 1008 33.7560
712 × 480 15.73460
704 × 572 15.62550

*2 Available for the composite, Y/C, component, RGB or SDI signal

Dimensions

Front

When an optional stand SU-560 is attached

602.4 (23 3/4) 386.2 (15 1/4) 273.5 (10 7/8)

Rear (VESA Mount Instruction)M4 100 (4) 142.3 (5) 5/8 100 (4) 100 (4) 209.7 (8-3/8) 100 (4) 100(4) 100(4)100(4)

* Length of M4 screws (4)

Monitor cabinet Attached object M4 screw 7 (9/32) to 9 (3/8)

Side

When an optional stand SU-560 is attached

110 (4 3/8) 454 (17 7/8) 302 (12)

Mass Approx. 8.3 kg (18 lb 5 oz) (when the optional stand and the input adaptor are not installed) Approx. 8.7 kg (19 lb 3 oz) (when the optional stand is not installed and two BKM-229X are installed)

AC adaptor5.3 (7/32) 264.8 (10 1/2) 18.6 (3/4) 54.5 (21/4) 95.2 (3 3/4) Unit: mm (inches)

Mass Approx. 1.2 kg (2 lb 10 oz)

French

Tally lamp

Tighten the screws.

Technical line drawing of a device panel with screwdriver and connector (no text or symbols)

TEMP COULNIVEAU COMPOSANTREGLAGE NTSC
1NORTH AMERICABAS BETA7.5 7.5
2LATIN AMERICAARGENTINA BAS SMPTE 0
PAL&PAL-N AREAPARAGUAY BAS SMPTE 0
URUGUAY BAS SMPTE 0
NTSC&PAL-M AREAOTHER AREA BAS BETA7.5 7.5
3AFRICA AUSTRALASIA EUROPE MIDDLE-EASTBAS SMPTE 0
4ASIA EXCEPT JAPANNTSC AREA BAS BETA7.5 7.5
PAL AREA BAS SMPTE 0
5JAPAN HAUTSMPTE 0

1 2 3~4

ASIA EXCEPT JAPAN NTSC AREA PAL AREA Zone NTSC Zone PAL

ASPECT

Indicator lamp

Remove the power cord

FARB-TEMP.KOMPONENTEN-PEGELNTSC-PEGEL
1NORTH AMERICANIEDR.BETA7.5 7.5
2LATIN AMERICAARGENTINA NIEDR. SMPTE 0
PAL&PAL-N AREAPARAGUAY NIEDR. SMPTE 0
URUGUAY NIEDR. SMPTE 0
NTSC&PAL-M AREAOTHER AREA NIEDR. BETA7.5 7.5
3AFRICA AUSTRALASIA EUROPE MIDDLE-EASTNIEDR.SMPTE 0
4ASIA EXCEPT JAPANNTSC AREA NIEDR. BETA7.5 7.5
PAL AREA NIEDR. SMPTE 0
5JAPAN HOCHSMPTE 0

2 3~4 1

ASIA EXCEPT JAPAN NTSC AREA PAL AREA NTSC-Region PAL-Region

ASPECT

LCD monitor (LMD-2451MD)

DC OUT: 24 V 5.0 A 5 V 0.060 A

Power consumption