EWS300AP - Access Point ENGENIUS - Free user manual and instructions
Find the device manual for free EWS300AP ENGENIUS in PDF.
| Product Type | Wireless Access Point |
| Brand | EnGenius |
| Model | EWS300AP |
| Wireless Standards | IEEE 802.11a/b/g/n/ac (Wave 2) |
| Frequency Bands | 2.4 GHz and 5 GHz |
| Max Data Rate | Up to 867 Mbps (5 GHz) and 300 Mbps (2.4 GHz) |
| Ethernet Ports | 1 x Gigabit Ethernet (PoE support) |
| Antennas | 2 internal omnidirectional antennas |
| Power Supply | PoE 802.3af or optional 12V/1A DC adapter |
| Power Consumption | < 10W |
| Dimensions (W x D x H) | 150 x 100 x 30 mm |
| Weight | 200 g |
| Mounting | Ceiling or wall (mounting kit included) |
| Security | WPA2, WPA3, MAC filtering, multiple SSIDs |
| Management | Web interface, SNMP, CLI |
| Operating Temperature | 0°C to 50°C |
| Humidity | 10% to 90% non-condensing |
| Certifications | CE, FCC |
| Package Contents | Access point, mounting bracket, quick start guide |
Frequently Asked Questions - EWS300AP ENGENIUS
User questions about EWS300AP ENGENIUS
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Access Point in PDF format for free! Find your manual EWS300AP - ENGENIUS and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. EWS300AP by ENGENIUS.
USER MANUAL EWS300AP ENGENIUS
natural_image
White EnGenius Bluetooth device with control buttons and indicator lights (no readable text or symbols beyond branding)EWS310AP
EWS320AP
version 1.0
Dual Band
Wireless N600 Manged Indoor Access Point
Wireless N900 Manged Indoor Access Point
Table of Contents
Chapter 1 .... 5
Key Features 6
Introduction....7
System Requirements....8
Package Contents 8
Applications 9
Technical Specifications 10
Physical Interface....11
Chapter 2....12
Considerations for Wireless Installation 13
Computer Settings....14
Hardware Installation....18
Mounting the EWS310AP/EWS320AP 19
Chapter 3....22
Default Settings....23
Web Configuration....24
Chapter 4....26
Device Status....27
Connections....30
Chapter 5....31
IPv4 Settings 32
IPv6 Settings 33
Spanning Tree Settings.... 34
Chapter 6....35
Wireless Settings....36
2.4GHz/5GHz SSID Profile 38
Wireless Security 40
Wireless MAC Filter 43
Traffic Shaping....44
Guest Network 45
Fast Handover 47
Management VLAN Settings....48
Chapter 7....49
SNMP Settings 50
CLI/SSH Settings....52
HTTPS Settings....53
Email Alert 54
Date and Time Settings 55
WiFi Scheduler....56
Tools....58
LED Control....61
Device Discovery....62
Chapter 8....63
Account Setting....64
Firmware Upgrade 65
Backup/Restore 66
System Log 67
Reset....68
Logout....69
Appendix 70
Appendix A - FCC Interference Statement 71
Appendix B - IC Interference Statement....72
Appendix C - CE Interference Statement....74
Chapter 1
Product Overview

natural_image
Exterior view of a white EnGenius 2.4.12 network device (no visible text or symbols on body)Introduction
Key Features
- Up to 28 dBm transmit power, enabling long range connectivity
- Supports IEEE802.11a/b/g/n wireless standards with up to 450 Mbps / 300Mbps data rate on each band
- Six/Four ^*2 internal 5dBi Omni-Directional MIMO antennas
- Can be used with included power adapter or via PoE with PoE 802.3at - capable Switches or Injectors
- Dual Band/Three Stream and Two Stream ^2
- Band Steering shifts dual band clients to 5 GHz for better throughput performance
• Secured Guest Network
Note: 1. EWS310AP supports 300Mbps; EWS320AP supports 450Mbps.
- EWS310AP has four antennas; EWS320AP has six antennas.
can be used with
802.3at
capable switches or injectors
Introduction
The EWS310AP/EWS320AP is an enhanced -powered, long-range, Dual-band concurrent Wireless 802.11a/b/g/n Access Point. It is designed to operate in numerous environments; from large homes, small and medium-sized businesses, multiple-floor offices, hotels, and other venues, to larger enterprise deployments. Its enhanced-powered, long-range characteristics make it a cost-effective alternative to ordinary Access Points that don't have the range and reach to connect to a growing number of wireless users who wish to connect to a large hotspot or business network.
The EWS310AP/EWS320AP supports the 2.4 GHz frequency band under the 802.11b/g/n mode while at the same time providing a 5 GHz band for communicating or transferring files in a less congested network frequency band.
The EWS310AP/EWS320AP also delivers up to 6x faster wireless speeds compared to legacy 802.11a/b/g wireless devices. Even though the EWS310AP/EWS320AP has been designed and engineered for heavy traffic and demanding business environments, in larger housing environments as it can efficiently extend the wireless range of an existing home router. This makes it especially ideal in architecturally-challenging structures, providing whole home connectivity.
To protect sensitive data during wireless transmissions, the EWS310AP/EWS320AP offers different encryption settings for wireless transmissions, including industry standard WPA and WPA2 encryption. The EWS310AP/EWS320AP also includes MAC address filtering to allow network administrators to offer network access only to known computers and other devices based on their MAC addresses.
Maximum data rates are based on IEEE 802.11 standards. Actual throughput and range may vary depending on many factors including environmental conditions, distance between devices, radio interference in the operating environment, and mix of devices in the network. Features and specifications subject to change without notice. Trademarks and registered trademarks are the property of their respective owners. For United States of America: Copyright © 2013 EnGenius Technologies, Inc. All rights reserved.
System Requirements
The following are the Minimum System Requirements in order to configure the device:
- Computer with an Ethernet interface or wireless network capability
- Windows OS (XP, Vista, 7, 8), Mac OS, or Linux-based operating systems
- Web-Browsing Application (i.e.: Internet Explorer, Firefox, Chrome, Safari, or another similar browser application)
Package Contents
The EWS310AP/EWS320AP package contains the following items (all items must be in package to issue a refund):
- EWS310AP or EWS320AP Access Point
- Power Adapter
- RJ-45 Ethernet Cable
- Quick Installation Guide
• Ceiling and Wall Mount Screw kit
Applications
Wireless LAN (WLAN) products are easy to install and highly efficient. The following list describes some of the many applications made possible through the power and flexibility of WLANs:
- Difficult-to-Wire Environments: There are many situations where wires cannot be installed, deployed easily, or cannot be hidden from view. Older buildings, sites with multiple buildings, and/or areas that make the installation of a Ethernet-based LAN impossible, impractical or expensive are sites where WLAN can be a network solution.
- Temporary Workgroups: Create temporary workgroups/networks in more open areas within a building; auditoriums, amphitheaters classrooms, ballrooms, arenas, exhibition centers, or temporary offices where one wants either a permanent or temporary Wireless LAN established.
- The Ability to Access Real-Time Information: Doctors/Nurses, Point-of-Sale Employees, and/or Warehouse Workers can access real-time information while dealing with patients, serving customers, and/or processing information.
- Frequently Changing Environments: Set up networks in environments that change frequently (i.e.: Show Rooms, Exhibits, etc.).
- Small Office and Home Office (SOHO) Networks: SOHO users require a cost-effective, easy, and quick installation of a small network.
- Training/Educational Facilities: Training sites at corporations or students at universities use wireless connectivity to exchange information between peers and easily access information for learning purposes.
Technical Specifications
| StandardIEEE802.11b/g/n on 2.4GHzIEEE802.11a/n on 5GHzIEEE802.3at | Power RequirementsExternal Power AdapterDC IN, 12V/2A |
| AntennaFour/Six* Internal 5 dBi Omni-Directional AntennasNote: EWS310AP has four antennas; EWS320AP has six antennas. | SecurityWEP (64/128bit)WPA/WPA2(TKIP/AES)Hidden ESSIDMAC address filtering, up to 50 fieldsL2 Isolation802.1X Authenticator (MD5/TLS/TTLS/PEAP)Guest Network |
| Physical Interface1 x 10/100/1000 Gigabit Ethernet Port1 x Reset Button1 x Power Connector | QoS (Quality of Service)WMM (Wireless Multimedia) |
| LED IndicatorPowerWLAN (Wireless Connection)LANMesh | Physical/Environment ConditionsOperating:Temperature: 32°F to 104°F (-0°C to 40°C)Humidity (Non-condensing): 90% or lessStorage:Temperature: -4°F to 140°F (-20°C to 60°C)Humidity (Non-condensing): 90% or less |
Physical Interface
Dimensions and Weights
Diameter: 6.36"
Height: 2.17"


natural_image
3D rendering of a white electronic device casing with labeled ports (no text or symbols beyond numbered labels)- Reset Button: Press and hold for over 10 seconds to reset to factory default settings.
- LED Indicators: LED lights for Mesh, WLAN 5GHz, WLAN 2.4GHz, Ethernet port, and Power
- LAN Port (802.3at PoE): Ethernet port for RJ-45 cable.
- Power Connector: 12V DC IN for Power.
- Ceiling (Wall) Mount Hole: Using the provided hardware, the EWS310AP/EWS320AP can be attached to a ceiling or wall.
- Kensington Security Slot: To protect your EWS310AP/EWS320AP, use the Kensington Security Slot to attach a cable lock.
Chapter 2
Before You Begin

natural_image
White EnGenius wireless router device with no visible text or symbols on the bodyBefore You Begin
This section will guide you through the installation process. Placement of the EnGenius EWS310AP/EWS320AP essential to maximize the Access Point's performance. Avoid placing the EWS310AP/EWS320AP in an enclosed space such as a closet, cabinet, or stairwell.
Considerations for Wireless Installation
The operating distance of all wireless devices can often not be pre-determined due to a number of unknown obstacles in the environment in which the device is deployed. Obstacles such as the number, thickness, and location of walls, ceilings, or other objects that the EWS310AP/EWS320AP's wireless signals must pass through can weaken the signal. Here are some key guidelines for allowing the EWS310AP/EWS320AP to have an optimal wireless range during setup.
- Keep the number of walls and/or ceilings between the EWS310AP/EWS320AP and other network devices to a minimum. Each wall and/or ceiling can reduce the signal strength, resulting in a lower overall signal strength.
- Building materials make a difference. A solid metal door and/or aluminum stubs may have a significant negative effect on the signal strength of the EWS310AP/EWS320AP. Locate your wireless devices carefully so the signal can pass through drywall and/or open doorways. Materials such as glass, steel, metal, concrete, water (example: fish tanks), mirrors, file cabinets, and/or brick can also diminish wireless signal strength.
- Interference from your other electrical devices and/or appliances that generate RF noise can also diminish the EWS310AP/EWS320AP's signal strength. The most common types of devices are microwaves or cordless phones.
Computer Settings
Windows XP/Windows 7
In order to use the EWS310AP/EWS320AP, you must first configure the TCP/IPv4 connection of your Windows OS computer system.
1. Click the Start button and open the Control Panel

Windows XP

Windows 7
2a. In Windows XP, click on Network Connections.

2b. In Windows 7, click View network status and tasks in the Network and Internet section, then select Change adapter
settings.

Network and Internet
View network status and tasks
Choose homegroup and sharing options
Control Panel Home
Change adapter settings
Change advanced sharing settings
-
Right click oLocal Area Connection and select Properties
-
Select Internet Protocol Version 4 (TCP/IPv4) then select Properties

Local Area Connection
Disable Status Repair
Bridge Connections
Create Shortcut Delete Rename
Properties

- SelectUse the following IP address and enter an IP address that is different from the EWS310AP/EWS320AP and Subnet mask, then cOK.
Note: Ensure that the IP address and Subnet mask are on the same subnet as the device.
For example: EWS310AP/EWS320AP IP address: 192.168.1.1
PC IP address: 192.168.1.2 - 192.168.1.255
PC Subnet mask: 255.255.255.0
Apple Mac OS X
- Go to System Preferences(it can be opened in theApplications folder or by electing it in the Apple Menu).
- Select Network in the Internet & Network section.

- HighlightEthernet.
- In Configure IPv4 select Manually.
- Enter an IP address that is different from the EWS310AP/EWS320AP and Subnet mask, then clickOK.
Note: Ensure that the IP address and Subnet mask are on the same subnet as the device.
For example: EWS310AP/EWS320AP IP address: 192.168.1.1
PC IP address: 192.168.1.2 - 192.168.1.255
PC Subnet mask: 255.255.255.0
- Click Apply when finished.

Hardware Installation
- Ensure that the computer in use has an Ethernet Controller port (RJ-45 Ethernet Port). For more information, verify with your computer's user manual.
- Connect one end of the Category 5e Ethernet cable into the RJ-45 port of the EWS310AP/EWS320AP and the other end to the RJ-45 port of the computer. Ensure that the cable is securely connected to both the EWS310AP/EWS320AP and the computer.
- Connect the Power Adapter DC connector to the DC-IN port of the EWS310AP/EWS320AP and the Power Adapter to an available electrical outlet. Once both connections are secure, verify the following:
a) Ensure that the POWER light is on (it will beorange).
b) Ensure that the 2.4 GHz/5 GHz WLAN light is on (it will be blue for 2.4G, and green for 5G).
c) Ensure that the LAN (Computer/EWS310AP/EWS320AP Connection) light is on (it will be blue).
d) Once all three lights are on, proceed to set up the Access Point using the computer.
This diagram depicts the hardware configuration.

flowchart
graph TD
A["Desktop"] --> B["Server"]
B --> C["Network Device"]
C --> D["User Interface"]
Mounting the EWS310AP/EWS320AP
Using the provided hardware, the EWS310AP/EWS320AP can be attached to a ceiling or wall.
To attach the EWS310AP/EWS320AP to a ceiling or wall using the mounting bracket:
-
Attach the mounting bracket to the wall or ceiling using the provided wall/ceiling mounting hardware kit.
-
Insert the provided short screws into the bottom cover of the EWS310AP/EWS320AP.
Leave enough of the screws exposed to ensure that the unit can be attached to the mounting bracket.
If extra space is required, use the provided spacers and long screws from the T-Rail mounting hardware kit to increase the space between the unit and the mounting bracket.

- Mount the EWS310AP/EWS320AP on the mounting bracket by rotating the unit clockwise about 90 degrees to secure it in place.
Attaching the EWS310AP/EWS320AP to a ceiling using the provided T-Rail connectors:
- Attach the T-Rail connectors to the bottom cover of the EWS310AP/EWS320AP using the provided short screws.
Note: Two sizes of T-Rail connectors are included in the mounting hardware kit: 15/16in (2.38cm) and 9/16in (1.43cm). If extra space is required to accommodate drop ceiling tiles, use the provided spacers and long screws.

- Line up the connected T-Rail connectors with an appropriately sized rail and press the unit onto the rail until it snaps into place.

Note: To protect your EWS310AP/EWS320AP, use the Kensington Security Slot to attach a cable lock (cable lock is not included).
Chapter 3
Configuring Your Access Point

natural_image
Exterior view of a white EnGenius wireless router device (no visible text or symbols on the device body)Configuring Your Access Point
This section will show you how to configure the device using the web-based configuration interface.
Default Settings
Please use your Ethernet port or wireless network adapter to connect the Access Point.
| IP Address | 192.168.1.1 |
| Username/Password | admin/admin |
Web Configuration
- Open a web browser (Internet Explorer/Firefox/Safari) and enter the IP Address http://192.168.1.1.

Note: If you have changed the default LAN IP Address of the Access Point, ensure you enter the correct IP Address.
- The default username and password are: admin. Once you have entered the correct username and password, click the Login button to open the web-based configuration page.

- If successful, you will be logged in and see the EWS310AP/EWS320AP User Menu.
EnGenius®
EWS320AP
Dual Radio AP, 3T3R, 450Mbps + 450Mbps
Changes: 0
Reset
Logout

Overview
Device Status
Connections

Network
Basic
Wireless

Management
Advanced
Time Zone
WiFi Scheduler
Tools

System Manager
Account
Firmware
Log
Device Information
| Device Name | EWS320AP |
| MAC Address | |
| - LAN | 88:DC:96:05:B0:68 |
| - Wireless LAN - 2.4GHz | 88:DC:96:05:B0:69 |
| - Wireless LAN - 5GHz | 88:DC:96:05:B0:6A |
| Country | Default |
| Current Local Time | Tue Jan 7 07:56:35 UTC 2014 |
| Firmware Version | 2.0.0 |
| Management VLAN ID | 4096 |
LAN Information - IPv4
| IP Address | 192.168.1.1 |
| Subnet Mask | 255.255.255.0 |
| Gateway | 192.168.1.1 |
| Primary DNS | 0.0.0.0 |
| Secondary DNS | 0.0.0.0 |
Chapter 4
Overview
Overview
The Overview section contains the following options:
- Device Status
- Connections
The following sections describe these options.
Device Status
Clicking the Device Statuslink under theOverview menu shows the status information about the current operating mode.
- The Device Information section shows general system information such as Device Name, MAC address, Current Time, Firmware Version, and Management VLAN ID
Device Information
| Device Name | EWS320AP |
| MAC Address | |
| - LAN | 88:DC:96:05:B0:68 |
| - Wireless LAN - 2.4GHz | 88:DC:96:05:B0:69 |
| - Wireless LAN - 5GHz | 88:DC:96:05:B0:6A |
| Country | Default |
| Current Local Time | Tue Jan 7 07:56:35 UTC 2014 |
| Firmware Version | 2.0.0 |
| Management VLAN ID | 4096 |
- The LAN Information section shows the Local Area Network settings such as the LAN IP Address, Subnet mask, Gateway, DNS Address, DHCP Client, and STP status.
LAN Information - IPv4
| IP Address | 192.168.1.1 |
| Subnet Mask | 255.255.255.0 |
| Gateway | 192.168.1.1 |
| Primary DNS | 0.0.0.0 |
| Secondary DNS | 0.0.0.0 |
| DHCP Client | Disable |
| Spanning Tree Protocol (STP) | Disable |
LAN Information - IPv6
| IP Address | N/A |
| Link-Local Address | fe80:8adc:96ff.fe05 b068 |
| Gateway | N/A |
| Primary DNS | N/A |
| Secondary DNS | N/A |
- The Wireless LAN Information 2.4 GHz/5GHz section shows wireless information such as Operating Mode, Frequency, and Channel. Since the EWS310AP/EWS320AP supports multiple-SSIDs, information about each SSID and security settings are displayed.
Wireless LAN Information - 2.4GHz
| Operation Mode | AP | ||||
| Wireless Mode | 802.11 B/G/N | ||||
| Channel Bandwidth | 20-40 MHz | ||||
| Channel | 2.412 GHz (Channel 1) | ||||
| Profile | SSID | Security | VID | 802.1Q | |
| #1 | EnGenius05B069_1-2.4GHz | None | 1 | Disable | |
| #2 | EnGenius05B069_2-2.4GHz | None | 2 | Disable | |
| #3 | EnGenius05B069_3-2.4GHz | None | 3 | Disable | |
| #4 | EnGenius05B069_4-2.4GHz | None | 4 | Disable | |
| #5 | EnGenius05B069_5-2.4GHz | None | 5 | Disable | |
| #6 | EnGenius05B069_6-2.4GHz | None | 6 | Disable | |
| #7 | EnGenius05B069_7-2.4GHz | None | 7 | Disable | |
| #8 | EnGenius05B069_8-2.4GHz | None | 8 | Disable | |
Wireless LAN Information - 5GHz
| Operation Mode | AP | ||||
| Wireless Mode | 802.11 A/N | ||||
| Channel Bandwidth | 40 MHz | ||||
| Channel | 5.66 GHz (Channel 132) | ||||
| Profile | SSID | Security | VID | 802.1Q | |
| #1 | EnGenius05B06A_1-5GHz | None | 51 | Disable | |
| #2 | EnGenius05B06A_2-5GHz | None | 52 | Disable | |
| #3 | EnGenius05B06A_3-5GHz | None | 53 | Disable | |
| #4 | EnGenius05B06A_4-5GHz | None | 54 | Disable | |
| #5 | EnGenius05B06A_5-5GHz | None | 55 | Disable | |
| #6 | EnGenius05B06A_6-5GHz | None | 56 | Disable | |
| #7 | EnGenius05B06A_7-5GHz | None | 57 | Disable | |
| #8 | EnGenius05B06A_8-5GHz | None | 58 | Disable | |
Connections
Clicking the Connections link under the Device Status menu displays the list of clients associated to the EWS310AP/EWS320AP's 2.4GHz/5GHz, along with the MAC address, TX, RX and signal strength for each client. Clicking Kick in the Block column removes this client.
Connection List - 2.4GHz
| SSID | MAC Address | TX | RX | RSSI | Block |
| Connection List - 5GHz | |||||
| SSID | MAC Address | TX | RX | RSSI | Block |
| EnGenius05B06A_1-5GHz | 00:02:6F:93:47:5C | 162Kb | 30Kb | -42dBm | Kick |
Refresh
Click Refresh to refresh the Connection List page.
Chapter 5
Network

natural_image
White EnGenius wireless router device with indicator lights (no visible text or symbols on body)Basic
This page allows you to modify the device's IP settings and the Spanning Tree settings. Enabling Spanning Tree protocol will prevent network loops in your LAN network.
IPv4 Settings
IPv4 Settings
| IP Network Setting | ○ DHCP ● Static IP |
| IP Address | 192.168.1.1 |
| Subnet Mask | 255.255.255.0 |
| Gateway | 192.168.1.1 |
| Primary DNS | 0.0.0.0 |
| Secondary DNS | 0.0.0.0 |
IP Network Setting: Select whether the device IP address will use the static IP address specified in the IP Address field or be obtained automatically when the device connects to a DHCP server.
IP Address The IP Address of this device.
IP Subnet Mask The IP Subnet mask of this device.
Gateway: The Default Gateway of this device. Leave it blank if you are unsure of this setting.
Primary/Secondary DNS The primary/secondary DNS address for this device.
IPv6 Settings
| IPv6 Settings | Link-local Address |
| IP Address | |
| Subnet Prefix Length | |
| Gateway | |
| Primary DNS | |
| Secondary DNS |
Link-Local Address Check this if you want to use Link-Local Address.
IP Address The IPv6 IP Address of this device.
Subnet Prefix Length The IPv6 Subnet Prefix Length of this device.
Gateway: The IPv6 Default Gateway of this device. Leave it blank if you are unsure of this setting.
Primary / Secondary DNS The primary / secondary DNS address for this device.
Spanning Tree Settings
Spanning Tree Protocol (STP) Settings
| Status | ○ Enable ● Disable | |
| Hello Time | 2 | seconds (1-10) |
| Max Age | 20 | seconds (6-40) |
| Forward Delay | 4 | seconds (4-30) |
| Priority | 32768 | (0-65535) |
Save
Save current setting(s)
Status: Enables or disables the Spanning Tree function.
Hello Time Specify Bridge Hello Time, in seconds. This value determines how often the device sends handshake packets to communicate information about the topology throughout the entire Bridged Local Area Network.
Max Age: Specify Bridge Max Age, in seconds. If another bridge in the spanning tree does not send a hello packet for a long period of time, it is assumed to be inactive.
Forward Delay: Specifies Bridge Forward Delay, in seconds. Forwarding Delay Time is the time spent in each of the Listening and Learning states before the Forwarding state is entered. This delay is provided so that when a new bridge comes onto a busy network, it analyzes data traffic before participating.
Priority: Specify the Priority Number. A smaller number has greater priority.
Save: Click Save to confirm the changes.
Chapter 6
2.4GHz & 5GHz Wireless

natural_image
Exterior view of a white EnGenius wireless router device (no visible text or symbols on the device body)Wireless Network
This page displays the current status of the Wireless settings of the EWS310AP/EWS320AP.
Wireless Settings
Wireless Settings
| Device Name | EWS320AP |
| Country / Region | Please Select a Country Code |
| Band Steering | ○ Enable ● DisableNOTE: In order for Band Steering function to work properly, both 2.4GHz and 5GHz SSID and Security Settings must be the same. |
Device Name: Enter a name for the device. The name you type appears in SNMP management. This name is not the SSID and is not broadcast to other devices.
Country/Region: Select a Country/Region to conform to local regulations.
Band Steering: Enable Band Steering to sends 802.11n clients to the 5GHz band, where 802.11b/g clients cannot go, and leaves the 802.11b/g clients in 2.4GHz to operate at their slower rates. Band Steering works within the Access Point by directing 5GHz-capable clients to that band.
*Note: In order for the Band Steering function to work properly, both the 2.4GHz and the 5GHz SSID and security settings must be under the same selection settings.
| 2.4GHz | 5GHz | |||
| Operation Mode | Access Point√ | □ Green√ | Access Point√ | □ Green√ |
| Wireless Mode | 802.11 B/G/N | √ | 802.11 A/N | √ |
| Channel HT Mode | 20/40 MHz | √ | 40 MHz | √ |
| Extension Channel | Upper Channel | √ | Lower Channel | √ |
| Channel | Auto | √ | Auto | √ |
| Transmit Power | Auto | √ | Auto | √ |
| Data Rate | Auto | √ | Auto | √ |
| RTS / CTS Threshold (1 - 2346) | 2346 | 2346 | ||
| Client Limits | 127 | ● Enable ○ Disable | 127 | ● Enable ○ Disable |
| Aggregation | ● Enable ○ Disable | ● Enable ○ Disable | ||
| 32 | Frames | 32 | Frames | |
| 50000 | Bytes(Max) | 50000 | Bytes(Max) | |
| AP Detection | Scan | Scan | ||
Wireless Mode: Supports 802.11b/g/n mixed mode in 2.4GHz and 802.11a/n mixed mode in 5GHz.
Channel HT Mode: The default channel bandwidth is 20/40MHz. The larger the channel bandwidth, the better the transmission quality and speed. This option is only available for 802.11n modes only.
Extension Channel: Use the drop-down menu to set the Extension Channel as Upper or Lower channel. An extension channel is a secondary channel used to bond with the primary channel to increase this range to 40MHz allowing for greater bandwidth. This option is only available when Wireless Mode is 802.11n and Channel HT Mode is 20/40 MHz or 40MHz.
Channel: Select the channel appropriate for your country's regulation.
Transmit Power: Select the transmit power for the radio. Increasing the power improves performance, but if two or more access points are operating in the same area on the same channel, it may cause interference.
Data Rate: Use the drop-down list to set the available transmit data rates permitted for wireless clients. The data rate affects the throughput of the access point. The lower the data rate, the lower the throughput, but the longer transmission distance.
RTS/CTS Threshold: Specifies the threshold package size for RTC/CTS. A small number causes RTS/CTS packets to be sent more often and consumes more bandwidth.
Client Limits: Limits the total number of clients.
Aggregation: Merges data packets into one packet. This option reduces the number of packets, but also increases packet sizes.
AP Detection: AP Detection can select the best channel to use by scanning nearby areas for Access Points.
2.4GHz/5GHz SSID Profile
Under Wireless Settings you can edit the SSID profile to fit your needs. ClickEdit under the SSID you would like to make changes to.
Wireless Settings - 2.4GHz
| No. | Enable | SSID | Edit | Security | Hidden SSID | Client Isolation | VLAN Isolation | VLAN ID |
| 1 | ☑ | EnGenius05B069_1-2.4GHz | Edit | None | ☐ | ☐ | 1 | |
| 2 | ☐ | EnGenius05B069_2-2.4GHz | Edit | None | ☐ | ☐ | 2 | |
| 3 | ☐ | EnGenius05B069_3-2.4GHz | Edit | None | ☐ | ☐ | 3 | |
| 4 | ☐ | EnGenius05B069_4-2.4GHz | Edit | None | ☐ | ☐ | 4 | |
| 5 | ☐ | EnGenius05B069_5-2.4GHz | Edit | None | ☐ | ☐ | 5 | |
| 6 | ☐ | EnGenius05B069_6-2.4GHz | Edit | None | ☐ | ☐ | 6 | |
| 7 | ☐ | EnGenius05B069_7-2.4GHz | Edit | None | ☐ | ☐ | 7 | |
| 8 | ☐ | EnGenius05B069_8-2.4GHz | Edit | None | ☐ | ☐ | 8 |
Wireless Settings - 5GHz
| No. | Enable | SSID | Edit | Security | Hidden SSID | Client Isolation | VLAN Isolation | VLAN ID |
| 1 | ☑ | EnGenius05B06A_1-5GHz | Edit | None | ☐ | ☐ | 51 | |
| 2 | ☐ | EnGenius05B06A_2-5GHz | Edit | None | ☐ | ☐ | 52 | |
| 3 | ☐ | EnGenius05B06A_3-5GHz | Edit | None | ☐ | ☐ | 53 | |
| 4 | ☐ | EnGenius05B06A_4-5GHz | Edit | None | ☐ | ☐ | 54 | |
| 5 | ☐ | EnGenius05B06A_5-5GHz | Edit | None | ☐ | ☐ | 55 | |
| 6 | ☐ | EnGenius05B06A_6-5GHz | Edit | None | ☐ | ☐ | 56 | |
| 7 | ☐ | EnGenius05B06A_7-5GHz | Edit | None | ☐ | ☐ | 57 | |
| 8 | ☐ | EnGenius05B06A_8-5GHz | Edit | None | ☐ | ☐ | 58 |
Enable: Check this option to enable this profile.
SSID: Specifies the SSID for the current profile.
Security: Displays the Security Mode the SSID uses. You can click Edit to change the security mode. For more details, see the next section.
Hidden SSID: Check this option to hide the SSID from clients. If checked, the SSID will not appear in the site survey.
Client Isolation: Check this option to prevent communication between client devices.
VLAN Isolation: Check this option to enable VLAN Isolation feature.
VLAN ID: Specifies the VLAN ID for the SSID profile.
Wireless Security
The Wireless Security section lets you configure the EWS310AP/EWS320AP's security modes: WEP, WPA-PSK, WPA2-PSK, WPA-PSK Mixed, WPA-Enterprise, WPA2-Enterprise and WPA Mixed Enterprise.
It is strongly recommended that you use WPA2-PSK. Click on the Edit button under Wireless Settings next to the SSID to change the security settings.
WEP
| Security Mode | WEP |
| Auth Type | Open System |
| Input Type | Hex |
| Key Length | 40/64-bit (10 hex digits or 5 ASCII char) |
| Default Key | 1 |
| Key1 | |
| Key2 | |
| Key3 | |
| Key4 |
Auth Type: Select Open System or Shared Key.
Input Type: ASCII: Regular Text (Recommended) or HEX: Hexadecimal Numbers (For advanced users).
Key Length: Select the desired option and ensure the wireless clients use the same setting. Your choices are: 64, 128, and 152-bit password lengths.
Default Key: Select the key you wish to be default. Transmitted data is ALWAYS encrypted using the Default Key; the other Keys are for decryption only. You must enter a Key Value for the Default Key.
Encryption Key: Enter the Key Value or values you wish to use. The default is none.
WPA-PSK/WPA2-PSK (Pre-Shared Key)
| Security Mode | WPA-PSK Mixed |
| Encryption | Both(TKIP+AES) |
| Passphrase | |
| Group Key Update Interval | 3600 |
Encryption: Select the WPA/WPA2 encryption type you would like to use. Available options are Both, TKIP(Temporal Key Integrity Protocol) and AES(Advanced Encryption Standard). Please ensure that your wireless clients use the same settings.
Passphrase: Wireless clients must use the same Key to associate the device. If using ASCII format, the Key must be from 8 to 63 characters in length. If using HEX format, the Key must be 64 HEX characters in length.
Group Key Update Interval: Specify how often, in seconds, the Group Key changes.
WPA/WPA2-Enterprise
| Security Mode | WPA Mixed-Enterprise |
| Encryption | Both(TKIP+AES) |
| Group Key Update Interval | 3600 |
| Radius Server | |
| Radius Port | 1812 |
| Radius Secret | |
| Radius Accounting | Disable |
| Radius Accounting Server | |
| Radius Accounting Port | 1813 |
| Radius Accounting Secret | |
| Interim Accounting Interval | 600 |
Encryption: Select the WPA/WPA2 encryption type you would like to use. Available options are Both, TKIP(Temporal Key Integrity
Protocol) and AES(Advanced Encryption Standard). Please ensure that your wireless clients use the same settings.
Group Key Update Interval: Specify how often, in seconds, the group key changes.
Radius Server: Enter the IP address of the Radius server.
Radius Port: Enter the port number used for connections to the Radius server.
Radius Secret: Enter the secret required to connect to the Radius server.
Radius Accounting: Enables or disables the accounting feature.
Radius Accounting Server: Enter the IP address of the Radius accounting server.
Radius Accounting Port: Enter the port number used for connections to the Radius accounting server.
Radius Accounting Secret: Enter the secret required to connect to the Radius accounting server.
Interim Accounting Interval Specify how often, in seconds, the accounting data sends.
Note: 802.11n does not allow WEP/WPA-PSK TKIP/WPA2-PSK TKIP security mode. The connection mode will automatically change from 802.11n to 802.11g.
Wireless MAC Filter
Wireless MAC Filter is used to allow or deny network access to wireless clients (computers, tablet PCs, NAS, smart phones, etc.) according to their MAC addresses. You can manually add a MAC address to restrict permission to access EWS310AP/EWS320AP. The default setting is: Disable Wireless MAC Filter.
Wireless MAC Filter

ACL (Access Control List) Mode: Determines whether network access is granted or denied to clients whose MAC addresses appear in the MAC address table on this page. Choices given are: Disabled, Deny MAC in the list, or Allow MAC in the list.
MAC Address: Enter the MAC address of the wireless client.
Add: Click Add to add the MAC address to the MAC Address table.
Delete: Deletes the selected entries.
Traffic Shaping
Traffic Shaping regulates the flow of packets leaving an interface to deliver improved Quality of Service.
Wireless Traffic Shaping
| Enable Traffic Shaping | ○ Enable | ● Disable |
| Download Limit | 100 | Mbps (1-999) |
| Upload Limit | 100 | Mbps (1-999) |
Save
Save current setting(s)
Enable Traffic Shaping: Select to Enable or Disable Wireless Traffic Shaping.
Download Limit: Specifies the wireless transmission speed used for downloading.
Upload Limit: Specifies the wireless transmission speed used for uploading.
Save: Click Save to apply the changes.
Guest Network
The Guest Network function allows administrators to grant Internet connectivity to visitors or guests while keeping other networked devices (computers and hard drives) and sensitive personal or company information private and secure.
Guest Network Settings
| Enable | SSID | Edit | Security | Hidden SSID | Client Isolation | |
| □ | EnGenius-2.4GHz_GuestNetw | Edit | None | □ | ☑ | |
| □ | EnGenius-5GHz_GuestNetwo | Edit | None | □ | ☑ | |
Enable SSID: Select to Enable or Disable SSID broadcasting.
SSID: Specify the SSID for the current profile. This is the name visible on the network to wireless clients.
Security: You can use None or WPA-PSK / WPA2-PSK security for this guest network.
Hidden SSID: Check this option to hide the SSID from broadcasting to discourage wireless users from connecting to a particular SSID.
Client Isolation: Check this option to prevent wireless clients associated with your access point to communicate with other wireless devices connected to the AP.
After enabling Guest Network in the SSID Config page, assign an IP Address, Subnet Mask and DHCP server IP address range for this Guest Network.
| Manual IP Settings | |
| - IP Address | 192.168.200.1 |
| - Subnet Mask | 255.255.255.0 |
| Automatic DHCP Server Settings | |
| - Starting IP Address | 192.168.200.100 |
| - Ending IP Address | 192.168.200.200 |
| - WINS Server IP | 0.0.0.0 |
Manual IP Settings
IP Address: Specify an IP Address for the Guest Network
Subnet Mask: Specify the the Subnet Mask IP Address for the Guest Network
Automatic DHCP Server Settings
Starting IP Address: Specify the starting IP Address range for the Guest Network.
Ending IP Address: Specify the ending IP Address range for the Guest Network.
WINS Server IP: Specify the WINS Server IP Address for the Guest Network. WINS means Windows Internet Name Service. It is Microsoft's implementation of NetBIOS Name Service (NBNS), a name server and service for NetBIOS computer names.
Fast Handover
With Fast Handover enabled, the AP will send a disassociation request to the wireless client and let it find another AP to handover and associate upon detecting the wireless client's RSSI value lower than specified. The RSSI value can be adjusted to allow more clients to stay associated to this AP. Note that setting the RSSI value too low may cause wireless clients to reconnect frequently.
Fast Handover
| Status | ○ Enable | ● Disable |
| RSSI | -70 | dBm (Range: -60dBm ~ -90dBm) |
Management VLAN Settings
This section allows you to assign a VLAN tag to the packets. A VLAN is a group of computers on a network whose software has been configured so that they behave as if they were on a separate Local Area Network (LAN). Computers on VLAN do not have to be physically located next to one another on the LAN.
Management VLAN Settings
Status
○ Enable
● Disable
4096
Caution: If you encounter disconnection issue during the configuration process, verify that the switch and the DHCP server can support the new VLAN ID and then connect to the new IP address.
Save
Save current setting(s)
Status: If your network includes VLANs and if tagged packets need to pass through the Access Point, select Enable and enter the VLAN ID. Otherwise, click Disable.
Save: Click Save to apply the changes.
Note: If you reconfigure the Management VLAN ID, you may lose your connection to the EWS310AP/EWS320AP. Verify that the DHCP server supports the reconfigured VLAN ID and then reconnect to the EWS310AP/EWS320AP using the new IP address.
Chapter 7
Management

natural_image
White EnGenius 3D router device with control buttons and indicator lights (no visible text or symbols on body)SNMP Settings
This page allows you to assign the Contact Details, Location, Community Name, and Trap Settings for Simple Network Management Protocol (SNMP). This is a networking management protocol used to monitor network attached devices. SNMP allows messages (called protocol data units) to be sent to various parts of the network. Upon receiving these messages, SNMP compatible devices (called agents) returns the data stored in their Management Information Bases. To configure SNMP Settings, click under Advanced tab on the side bar under Management
SNMP Settings
| Status | ● Enable ○ Disable | |
| Contact | ||
| Location | ||
| Port | 161 | |
| Community Name (Read Only) | public | |
| Community Name (Read Write) | private | |
| Trap Destination | ||
| - Port | 162 | |
| - IP Address | ||
| - Community Name | public | |
| SNMPv3 Settings | ||
| - Status | ● Enable ○ Disable | |
| - Username | admin | (1-31 Characters) |
| - Authorized Protocol | MD5 | |
| - Authorized Key | 12345678 | (8-32 Characters) |
| - Private Protocol | DES | |
| - Private Key | 12345678 | (8-32 Characters) |
| - Engine ID | ||
Status: Enables or Disables the SNMP feature.
Contact: Specifies the contact details of the device.
Location: Specifies the location of the device.
Port: Displays the port number.
Community Name (Read Only): Specifies the password for the SNMP community for read only access.
Community Name (Read/Write): Specifies the password for the SNMP community with read/write access.
Trap Destination Address: Specifies the port and IP address of the computer that will receive the SNMP traps.
Trap Destination Community Name Specifies the password for the SNMP trap community.
SNMPv3 Status: Enables or Disables the SNMPv3 feature.
User Name: Specifies the username for the SNMPv3.feature
Auth Protocol: Select the Authentication Protocol type: MDS or SHA.
Auth Key: Specify the Authentication Key for authentication.
Priv Protocol: Select the Privacy Protocol type: DES.
Priv Key: Specifies the privacy key for privacy.
Engine ID: Specifies the Engine ID for SNMPv3.
CLI/SSH Settings
Most users will configure the device through the graphical user interface (GUI). However, for those who prefer an alternative method there is the command line interface (CLI). The CLI can be access through a command console, modem or Telnet connection. For security's concern, you can enable SSH (Secure Shell) to establish a secure data communication.
CLI Setting
| Status | ● Enable ○ Disable |
| SSH Setting | |
| Status | ○ Enable ● Disable |
CLI Status: Select Enable or Disable to enable or disable the ability to modify the EWS310AP/EWS320AP via a command line interface (CLI).
SSH Status: Select Enable or Disable to enable or disable the ability to modify the EWS310AP/EWS320AP via a command line interface (CLI) with a secure channel.
HTTPS Settings
Hypertext Transfer Protocol Secure (HTTPS) is a communications protocol for secure communication over a computer network, with especially wide deployment on the Internet. Technically, it is not a protocol in and of itself; rather, it is the result of simply layering the Hypertext Transfer Protocol (HTTP) on top of the SSL/TLS protocol, thus adding the security capabilities of SSL/TLS to standard HTTP communications.
HTTPS Settings
| Status | ● Enable ○ Disable |
| HTTPS forward | ○ Enable ● Disable |
Status: Select Enable or Disable to enable or disable the ability to modify the EWS310AP/EWS320AP via a HTTPS. HTTPS forward: Enable this option; it will be forwarded to HTTPS if user uses HTTP to access EWS310AP/EWS320AP.
Email Alert
EWS310AP/EWS320AP will send email alerts when EWS310AP/EWS320AP's configuration has been changed.
Email Alert
![Status Enable - From To - Subject [Email-Alert][EWS320AP][88:DC:96:05:B0:68] Configur Email Account - Username - Password - SMTP Server Port: 25 - Security Mode None Send Test Mail Apply Apply saved settings to take effect](/content/2026/06/1271501/images/0f5bfb934df9f861072ea8f2b70d91317d1b3d4d323ec7c9618b178bb44a217c.jpg)
Status: Check Enable to enable Email Alert feature.
From: Enter the address to show as the sender of the email.
To: Enter the address to show as the receiver of the email.
Subject: Enter the subject to show as the subject of the email.
Email Account
Username/Password: Enter the username and password required to connect to the SMTP server.
SMTP Server/Port: Enter the IP address/domain name and port of the SMTP server. The default port of SMTP Server is port 25.
Security Mode Select the mode of security for the Email alert. The options are None, SSL/TLS and STARTTLS.
Send Test Mail: Click Send Test Mailbutton to test the Email Alert setup.
Apply: Click Apply to save the changes.
Date and Time Settings
This page allows you to set the internal clock of the EWS310AP/EWS320AP. To access the Date and Time settings, click Time Zone under the Management tab on the side bar.
Date and Time Settings
○ Manually Set Date and Time
| Date: | 2014 | / | 01 | / | 07 |
| Time: | 11 | : | 16 | (24-Hour) | |
| Synchronize with PC | |||||
- Automatically Get Date and Time
NTP Server: 209.81.9.7
Time Zone
Time Zone: UTC+00:00 Gambia, Liberia, Morocco
□ Enable Daylight Saving
| Start: | January | 1st | Sun | 12 am |
| End: | January | 1st | Mon | 12 am |
Apply
Apply saved settings to take effect
Manually Set Date and Time: Manually specify the date and time.
Synchronize with PC: Click to Synchronize the EWS310AP/EWS320AP with the computer's internal clock.
Automatically Get Date and Time: Enter the IP address of an NTP server or use the default NTP server to have the internal clock set automatically.
Time Zone: Choose the time zone you would like to use from the drop-down list.
Enable Daylight Savings: Check the box to enable or disable daylight savings time for the EWS310AP/EWS320AP. Next, enter the dates that correspond to the present year's daylight savings time.
Click Apply to save the changes.
WiFi Scheduler
Use the schedule function to reboot EWS310AP/EWS320AP or control the wireless availability on a routine basis. The Schedule function relies on the GMT time setting acquired from a network time protocol (NTP) server. For details on how to connect the EWS310AP/EWS320AP to an NTP server, see Date and Time Settings.
Auto Reboot Settings
You can specify how often you would like to reboot the EWS310AP/EWS320AP.
Auto Reboot Settings
| Status | ○ Enable ● Disable | ||||||
| Timer | □ Sunday □ Monday □ Tuesday □ Wednesday □ Thursday □ Friday □ Saturday | ||||||
| 0 : 0 | |||||||
Status: Enables or disables the Auto Reboot function.
Timer: Specifies the time and frequency in rebooting the EWS310AP/EWS320AP by Min, Hour and Day.
WiFi Scheduler
Wi-Fi Scheduler
| Status | ○ Enable ● DisableNOTE: Please assure that the Time Zone Settings is synced with your local time when enabling the Wi-Fi Scheduler. | |||||
| Wireless Radio | 2.4GHz√ | |||||
| SSID Selection | EnGenius05B069_1-2 4GHz√ | |||||
| Schedule Templates | Choose a template √ | |||||
| Schedule Table | Day | Availability | Duration | |||
| Sunday | available √ | 00 | : 00 | ~ 24 | : 00 | |
| Monday | available √ | 00 | : 00 | ~ 24 | : 00 | |
| Tuesday | available √ | 00 | : 00 | ~ 24 | : 00 | |
| Wednesday | available √ | 00 | : 00 | ~ 24 | : 00 | |
| Thursday | available √ | 00 | : 00 | ~ 24 | : 00 | |
| Friday | available √ | 00 | : 00 | ~ 24 | : 00 | |
| Saturday | available √ | 00 | : 00 | ~ 24 | : 00 | |
Save
Save current setting(s)
Status: Enables or disables the WiFi Scheduler function.
Wireless Radio: Select 2.4GHz or 5GHz to use WiFi Schedule.
SSID Selection: Select a SSID to use WiFi Schedule.
Schedule Templates: EWS310AP/EWS320AP provides three templates: Always available, Available 8-5 daily and Available 8-5 daily except weekends. Select Custom schedule if you want to set the schedule manually.
Schedule Table: Set the schedule manually.
Tools
This section allows you to analyze the connection quality of the EWS310AP/EWS320AP and trace the routing table to a target in the network.
Ping Test Parameters
Ping Test Parameters
| Target IP / Domain Name | ||
| Ping Packet Size | 64 | Bytes |
| Number of Pings | 4 | |
| Start | ||
Target IP/Domain Name: Enter the IP address or Domain name you would like to search.
Ping Packet Size: Enter the packet size of each ping.
Number of Pings: Enter the number of times you wish to ping.
Start: Click Start to begin pinging target device (via IP).
Traceroute Parameters
Traceroute Test Parameters

Target IP/Domain Name: Enter an IP address or domain name you wish to trace.
Start: Click Start to begin the trace route operation.
Stop: Halts the traceroute test.
Speed Test Parameters
Speed Test Parameters
| Target IP / Domain Name | ||
| Time Period | 20 | sec |
| Check Interval | 5 | sec |
| Start | ||
| < | > | |
| IPv4 Port | 5001 | |
| IPv6 Port | 5002 | |
Target IP/Domain Name: Enter an IP address or domain name you wish to run a Speed Test for.
Time Period : Enter the time in seconds that you would like the test to run for and in how many intervals.
Start: Starts the Speed Test.
IPv4 / IPv6 Port: EWS310AP/EWS320AP uses IPv4 port 5001 and IPv6 port 5002 for the speed test.
LED Control
This section allows you to control the LED control functions: Power status, LAN interface and 2.4GHz/5GHz WLAN interface.
LED Control
| Power | ● Enable ○ Disable |
| LAN | ● Enable ○ Disable |
| WLAN-2.4GHz | ● Enable ○ Disable |
| WLAN-5GHz | ● Enable ○ Disable |
| Apply | Apply saved settings to take effect |
Click Apply to save the settings after selecting your choices from the boxes.
Device Discovery
Under Device Discovery, you can choose for the EWS310AP/EWS320AP to automatically scan for local devices to connect to. Click Scan to begin the process.
Device Discovery
| Device Name | Operation Mode | IP Address | System MAC Address | Firmware Version |
| Scan |
Chapter 8
System Manager

natural_image
White EnGenius 3D router device with control buttons and indicator lights (no visible text or symbols on body)Account Setting
This page allows you to change the EWS310AP/EWS320AP username and password. By default, the username is admin and the password is admin. The password can contain from 0 to 12 alphanumeric characters and is case sensitive.
Account Settings
| Administrator Username | admin |
| Current Password | |
| New Password | |
| Verify Password |
Apply
Apply saved settings to take effect
Administrator Username: Enter a new username for logging in to the Administrator Username entry box.
Current Password: Enter the old password for logging in to the Current Password entry box.
New Password: Enter the new password for logging in to the New Password entry box.
Verify Password: Re-enter the new password in the Verify Password entry box for confirmation.
Apply: Click Apply to save the changes.
Note: it is highly recommended that you change your password to something more unique for greater security.
Firmware Upgrade
This page allows you to upgrade the Firmware of the EWS310AP/EWS320AP.
Firmware Upgrade
Current Firmware Version: 2.0.0
Select the new firmware from your hard disk.

To Perform the Firmware Upgrade:
- Click theBrowse... button and navigate the OS File System to the location of the Firmware upgrade file.
- Select the upgrade file. The name of the file will appear in the Upgrade File field.
- Click theUpload button to commence the Firmware upgrade.
Note: The device is unavailable during the upgrade process and must restart when the upgrade is completed. Any connections to or through the device will be lost.
Backup/Restore
This page allows you to save the current device configurations. When you save the configurations, you can also reload the saved configurations into the device through the Restore New Settings from a file folder. If extreme problems occur, or if you have set the EWS310AP/EWS320AP incorrectly, you can use the Reset button in the Reset to Default section to restore all the configurations of the EWS310AP/EWS320AP to the original default settings. To Configure the Backup/Restore Settings, click Firmware under the Systems Manager tab.
Backup/Restore Settings
| Factory Setting | |||
| - Backup Setting | Export | ||
| - Restore New Setting | Browse... | Import | |
| - Reset to Default | Reset | ||
| User Setting | |||
| - Back Up Setting as Default | Backup | ||
| - Restore to User Default | Restore | ||
Factory Setting
Backup Setting: Click Export to save the current device configurations to a file.
Restore New Setting: Choose the file you wish restore for settings and click Import.
Reset to Default: Click the Reset button to restore the EWS310AP/EWS320AP to its factory default settings.
User Setting
Back Up Setting as Default: Click Backup to backup the user settings you would like to use as the default settings. Restore to User Default: Click Restore to restore the EWS310AP/EWS320AP to user's default settings.
System Log
This page allows you to setup the System Log and local log functions of the EWS310AP/EWS320AP. Click Systems Manager tab to open up the System Log page.
Log under the
System Log
![Status Enable Disable Log type All Refresh Clear Jan 7 11:20:01 EWS320AP user.notice root: starting ntpd Jan 7 11:20:01 EWS320AP cron.info crond[2159]: crond: USER root pid 3505 cmd sch Jan 7 11:20:01 EWS320AP cron.info crond[2159]: crond: USER root pid 3501 cmd . Jan 7 11:18:01 EWS320AP cron.info crond[2159]: crond: USER root pid 969 cmd sche Jan 7 11:16:01 EWS320AP cron.info crond[2159]: crond: USER root pid 2252 cmd sche Jan 7 11:15:01 EWS320AP user.notice root: starting ntpd Jan 7 11:15:01 EWS320AP cron.info crond[2159]: crond: USER root pid 1011 cmd . Jan 7 11:14:01 EWS320AP cron.info crond[2159]: crond: USER root pid 3582 cmd sche Jan 7 11:12:01 EWS320AP cron.info crond[2159]: crond: USER root pid 954 cmd sche Jan 7 11:10:01 EWS320AP user.notice root: starting ntpd < > Remote Log Enable Disable Log Server IP Address 0.0.0.0](/content/2026/06/1271501/images/b529156143f939a9cb76384fd771956563c124c73ccb61cdd45830cabbfe9169.jpg)
Apply
Apply saved settings to take effect
Status: Enables or disables the System Log function.
Log Type: Select the Log Type mode you would like to use.
Remote Log: Enables or disables the Remote Log feature. If enabled, enter the IP address of the Log you would like to remote to.
Log Server IP Address: Enter the IP address of the log server.
Apply: Click Apply to save the changes.
Reset
In some circumstances, you may be required to force the device to reboot. Click a Reboot the Deviceto reboot the device.

Logout
Click Logout, it will pop up a warning window. Click OK to logout.


Appendix

natural_image
White EnGenius wireless router device with no visible text or symbols on the bodyAppendix A - FCC Interference Statement
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
• Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.

FCC Caution:
Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Operations in the 5.15-5.25 GHz band are restricted to indoor usage only.
IMPORTANT NOTE:
Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 23 cm between the radiator & your body.
Appendix B - IC Interference Statement
Industry Canada Statement
This device complies with RSS-210 of the Industry Canada Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
(i) the device for operation in the band 5150-5250 MHz is only for indoor use to reduce the potential for harmful interference to co-channel mobile satellite systems;
(ii) high-power radars are allocated as primary users (i.e. priority users) of the bands 5250-5350 MHz and 5650-5850 MHz and that these radars could cause interference and/or damage to LE-LAN devices.

Avertissement:
Radiation Exposure Statement
This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body.
Europe – EU Declaration of Conformity
EN60950-1
Safety of Information Technology Equipment
EN50385
Generic standard to demonstrate the compliance of electronic and electrical apparatus with the basic restrictions related to human exposure to electromagnetic fields (0 Hz - 300 GHz)
• EN 300 328
Electromagnetic compatibility and Radio spectrum Matters (ERM); Wideband Transmission systems; Data transmission equipment operating in the 2,4 GHz ISM band and using spread spectrum modulation techniques; Harmonized EN covering essential requirements under article 3.2 of the R&TTE Directive
• EN 301 893
Broadband Radio Access Networks (BRAN); 5 GHz high performance RLAN; Harmonized EN covering essential requirements of article 3.2 of the R&TTE Directive
• EN 301 489-1
Electromagnetic compatibility and Radio Spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements
• EN 301 489-17
Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 17: Specific conditions for 2,4 GHz wideband transmission systems and 5 GHz high performance RLAN equipment
This device is a 5GHz wideband transmission system (transceiver), intended for use in all EU member states and EFTA countries, except in France and Italy where restrictive use applies.
In Italy the end-user should apply for a license at the national spectrum authorities in order to obtain authorization to use the device for setting up
outdoor radio links and/or for supplying public access to telecommunications and/or network services.
This device may not be used for setting up outdoor radio links in France and in some areas the RF output power may be limited to 10mW EIRP in the frequency range of 2454 - 2483.5 MHz. For detailed information the end-user should contact the national spectrum authority in France.
CE0560!
| csČesky [Czech] | [Jméno výrobce] tímto prohlašuje, že tento [typ zařízení] je ve shodě se základními požadavky a dalšími příslušnými ustanoveními směrnice 1999/5/ES. |
| daDansk [Danish] | Undertegnede [fabrikantens navn] erklærer herved, at følgende udstyr [udstyrets typebetegnelse] overholder de væsentlige krav og øvrige relevante krav i direktiv 1999/5/EF. |
| deDeutsch [German] | Hiermit erklärt [Name des Herstellers], dass sich das Gerät [Gerätetyp] in Übereinstimmung mit den grundlegenden Anforderungen und den übrigen einschlägigen Bestimmungen der Richtlinie 1999/5/EG befindet. |
| etEesti [Estonian] | Käesolevaga kinnitab [tootja nimi = name of manufacturer] seadme [seadme tüüp = type of equipment] vastavust direktiivi 1999/5/EÜ põhinõuetele ja nimetatud direktiivist tulenevatele teistele asjakohastele sätetele. |
| enEnglish | Hereby, [name of manufacturer], declares that this [type of equipment] is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. |
| esEspañol [Spanish] | Por medio de la presente [nombre del fabricante] declara que el [clase de equipo] cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999/5/CE. |
| elEλληνική [Greek] | ME THN ΠΑΡΟΥΣΑ [name of manufacturer] ΔΗΛΩΝΕΙ OTI [type of equipment] ΣΥΜΜΟΡΦΩΝΕΤΑΙ ΠΡΟΣ ΤΙΣ ΟΥΣΙΩΔΕΙΣ ΑΠΑΙΤΗΣΕΙΣ ΚΑΙ ΤΙΣ ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ ΔΙΑΤΑΞΕΙΣ ΤΗΣ ΟΔΗΓΙΑΣ 1999/5/EK. |
| frFrançais [French] | Par la présente [nom du fabricant] déclare que l'appareil [type d'appareil] est conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999/5/CE. |
| itItaliano [Italian] | Con la presente [nome del costruttore] dichiara che questo [tipo di apparecchio] è conforme airequisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999/5/CE. |
| Latviski [Latvian] | Ar šo [name of manufacturer / izgatavotāja nosaukums] deklarē, ka [type of equipment / iekārtas tips] atbilst Direktīvas 1999/5/EK būtiskajām prasībām un citiem ar to saistītajiem noteikumiem. |
| Lietuvių [Lithuanian] | Šiuo [manufacturer name] deklarujoja, kad šis [equipment type] atitinka esminius reikalavimus ir kitas 1999/5/EB Direktyvos nuostatas. |
| Nederlands [Dutch] | Hierbij verklaart [naam van de fabrikant] dat het toestel [type van toestel] in overeenstemming is met de essentiële eisen en de andere relevante bepalingen van richtlijn 1999/5/EG. |
| Malti [Maltese] | Hawnhekk, [isem tal-manifattur], jiddikjara li dan [il-mudel tal-prodott] jikkonforma mal-ħtiġijiet essenzjali u ma provvedimenti oħrajn relevanti li hemm fid-Dirrettiva 1999/5/EC. |
| Magyar [Hungarian] | Alulírott, [gyártó neve] nyilatkozom, hogy a [... típus] megfelel a vonatkozó alapvetō követelményeknek és az 1999/5/EC irányelv egyéb előírásainak. |
| Polski [Polish] | Niniejszym [nazwa producenta] oświadcza, że [nazwa wyrobu] jest zgodny z zasadniczymi wymogami oraz pozostałymi stosownymi postanowieniami Dyrektywy 1999/5/EC. |
| Português [Portuguese] | [Nome do fabricante] declara que este [tipo de equipamento] está conforme com os requisitos essenciais e outras disposições da Directiva 1999/5/CE. |
| Slovensko [Slovenian] | [Ime proizvajalca] izjavlja, da je ta [tip opreme] v skladu z bistvenimi zahtevami in ostalimi relevantnimi določili direktive 1999/5/ES. |
| Slovensky [Slovak] | [Meno výrobcu] týmto vyhlasuje, že [typ zariadenia] spĺňa základné požiadavky a všetky príslušné ustanovenia Smernice 1999/5/ES. |
| Suomi [Finnish] | [Valmistaja = manufacturer] vakuuttaa täten että [type of equipment = laitteen tyyppimerkintä] tyyppinen laite on direktiivin 1999/5/EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen. |
| Svenska [Swedish] | Härmed intygar [företag] att denna [utrustningstyp] står l överensstämmelse med de väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av direktiv 1999/5/EG. |