Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Wireless Access Point
Brand EnGenius
Model EWS300AP
Wireless Standards IEEE 802.11a/b/g/n/ac (Wave 2)
Frequency Bands 2.4 GHz and 5 GHz
Max Data Rate Up to 867 Mbps (5 GHz) and 300 Mbps (2.4 GHz)
Ethernet Ports 1 x Gigabit Ethernet (PoE support)
Antennas 2 internal omnidirectional antennas
Power Supply PoE 802.3af or optional 12V/1A DC adapter
Power Consumption < 10W
Dimensions (W x D x H) 150 x 100 x 30 mm
Weight 200 g
Mounting Ceiling or wall (mounting kit included)
Security WPA2, WPA3, MAC filtering, multiple SSIDs
Management Web interface, SNMP, CLI
Operating Temperature 0°C to 50°C
Humidity 10% to 90% non-condensing
Certifications CE, FCC
Package Contents Access point, mounting bracket, quick start guide

Frequently Asked Questions - EWS300AP ENGENIUS

How do I reset the EWS300AP to factory defaults?
Press and hold the reset button on the back of the device for 10 seconds using a paperclip. The device will reboot with factory settings.
What is the default IP address of the EWS300AP?
The default IP address is 192.168.1.1. Ensure your computer is on the same subnet to access the web interface.
Can the EWS300AP be powered via PoE?
Yes, it supports IEEE 802.3af PoE. Use a PoE switch or injector for power and data over a single Ethernet cable.
How many concurrent users can the EWS300AP support?
It can support approximately 30-50 concurrent users for typical office or home use, depending on network traffic.
Does the EWS300AP support mesh networking?
No, the EWS300AP is a standalone access point and does not support mesh. It can be managed centrally if paired with an EnGenius EWS switch or controller.
What is the maximum range of the EWS300AP?
Indoor range is approximately 100 meters in open space. Actual range depends on obstacles and interference.
How do I configure multiple SSIDs on the EWS300AP?
Log into the web interface, go to Wireless settings, and add new SSIDs. Each SSID can have its own VLAN and security settings.
Is the EWS300AP compatible with WPA3?
Yes, it supports WPA3-Personal for enhanced security. Enable it in the wireless security settings.
What should I do if the EWS300AP is not powering on?
Check the PoE source or power adapter. Ensure the Ethernet cable is properly connected and the device is receiving power. Try a different cable or port.
Can I mount the EWS300AP outdoors?
No, it is designed for indoor use only. Exposure to moisture or extreme temperatures may damage the device.

User questions about EWS300AP ENGENIUS

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Access Point in PDF format for free! Find your manual EWS300AP - ENGENIUS and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. EWS300AP by ENGENIUS.

USER MANUAL EWS300AP ENGENIUS

natural_image White EnGenius Bluetooth device with control buttons and indicator lights (no readable text or symbols beyond branding)

EWS310AP

EWS320AP

version 1.0

Dual Band

Wireless N600 Manged Indoor Access Point

Wireless N900 Manged Indoor Access Point

Table of Contents

Chapter 1 .... 5

Key Features 6

Introduction....7

System Requirements....8

Package Contents 8

Applications 9

Technical Specifications 10

Physical Interface....11

Chapter 2....12

Considerations for Wireless Installation 13

Computer Settings....14

Hardware Installation....18

Mounting the EWS310AP/EWS320AP 19

Chapter 3....22

Default Settings....23

Web Configuration....24

Chapter 4....26

Device Status....27

Connections....30

Chapter 5....31

IPv4 Settings 32

IPv6 Settings 33

Spanning Tree Settings.... 34

Chapter 6....35

Wireless Settings....36

2.4GHz/5GHz SSID Profile 38

Wireless Security 40

Wireless MAC Filter 43

Traffic Shaping....44

Guest Network 45

Fast Handover 47

Management VLAN Settings....48

Chapter 7....49

SNMP Settings 50

CLI/SSH Settings....52

HTTPS Settings....53

Email Alert 54

Date and Time Settings 55

WiFi Scheduler....56

Tools....58

LED Control....61

Device Discovery....62

Chapter 8....63

Account Setting....64

Firmware Upgrade 65

Backup/Restore 66

System Log 67

Reset....68

Logout....69

Appendix 70

Appendix A - FCC Interference Statement 71

Appendix B - IC Interference Statement....72

Appendix C - CE Interference Statement....74

Chapter 1

Product Overview

ENGENIUS EWS300AP - Product Overview - 1

natural_image Exterior view of a white EnGenius 2.4.12 network device (no visible text or symbols on body)

Introduction

Key Features

  • Up to 28 dBm transmit power, enabling long range connectivity
  • Supports IEEE802.11a/b/g/n wireless standards with up to 450 Mbps / 300Mbps data rate on each band
  • Six/Four ^*2 internal 5dBi Omni-Directional MIMO antennas
  • Can be used with included power adapter or via PoE with PoE 802.3at - capable Switches or Injectors
  • Dual Band/Three Stream and Two Stream ^2
  • Band Steering shifts dual band clients to 5 GHz for better throughput performance
    • Secured Guest Network

Note: 1. EWS310AP supports 300Mbps; EWS320AP supports 450Mbps.

  1. EWS310AP has four antennas; EWS320AP has six antennas.

can be used with

802.3at

capable switches or injectors

Introduction

The EWS310AP/EWS320AP is an enhanced -powered, long-range, Dual-band concurrent Wireless 802.11a/b/g/n Access Point. It is designed to operate in numerous environments; from large homes, small and medium-sized businesses, multiple-floor offices, hotels, and other venues, to larger enterprise deployments. Its enhanced-powered, long-range characteristics make it a cost-effective alternative to ordinary Access Points that don't have the range and reach to connect to a growing number of wireless users who wish to connect to a large hotspot or business network.

The EWS310AP/EWS320AP supports the 2.4 GHz frequency band under the 802.11b/g/n mode while at the same time providing a 5 GHz band for communicating or transferring files in a less congested network frequency band.

The EWS310AP/EWS320AP also delivers up to 6x faster wireless speeds compared to legacy 802.11a/b/g wireless devices. Even though the EWS310AP/EWS320AP has been designed and engineered for heavy traffic and demanding business environments, in larger housing environments as it can efficiently extend the wireless range of an existing home router. This makes it especially ideal in architecturally-challenging structures, providing whole home connectivity.

To protect sensitive data during wireless transmissions, the EWS310AP/EWS320AP offers different encryption settings for wireless transmissions, including industry standard WPA and WPA2 encryption. The EWS310AP/EWS320AP also includes MAC address filtering to allow network administrators to offer network access only to known computers and other devices based on their MAC addresses.

Maximum data rates are based on IEEE 802.11 standards. Actual throughput and range may vary depending on many factors including environmental conditions, distance between devices, radio interference in the operating environment, and mix of devices in the network. Features and specifications subject to change without notice. Trademarks and registered trademarks are the property of their respective owners. For United States of America: Copyright © 2013 EnGenius Technologies, Inc. All rights reserved.

System Requirements

The following are the Minimum System Requirements in order to configure the device:

  • Computer with an Ethernet interface or wireless network capability
  • Windows OS (XP, Vista, 7, 8), Mac OS, or Linux-based operating systems
  • Web-Browsing Application (i.e.: Internet Explorer, Firefox, Chrome, Safari, or another similar browser application)

Package Contents

The EWS310AP/EWS320AP package contains the following items (all items must be in package to issue a refund):

  • EWS310AP or EWS320AP Access Point
  • Power Adapter
  • RJ-45 Ethernet Cable
  • Quick Installation Guide
    • Ceiling and Wall Mount Screw kit

Applications

Wireless LAN (WLAN) products are easy to install and highly efficient. The following list describes some of the many applications made possible through the power and flexibility of WLANs:

  • Difficult-to-Wire Environments: There are many situations where wires cannot be installed, deployed easily, or cannot be hidden from view. Older buildings, sites with multiple buildings, and/or areas that make the installation of a Ethernet-based LAN impossible, impractical or expensive are sites where WLAN can be a network solution.
  • Temporary Workgroups: Create temporary workgroups/networks in more open areas within a building; auditoriums, amphitheaters classrooms, ballrooms, arenas, exhibition centers, or temporary offices where one wants either a permanent or temporary Wireless LAN established.
  • The Ability to Access Real-Time Information: Doctors/Nurses, Point-of-Sale Employees, and/or Warehouse Workers can access real-time information while dealing with patients, serving customers, and/or processing information.
  • Frequently Changing Environments: Set up networks in environments that change frequently (i.e.: Show Rooms, Exhibits, etc.).
  • Small Office and Home Office (SOHO) Networks: SOHO users require a cost-effective, easy, and quick installation of a small network.
  • Training/Educational Facilities: Training sites at corporations or students at universities use wireless connectivity to exchange information between peers and easily access information for learning purposes.

Technical Specifications

StandardIEEE802.11b/g/n on 2.4GHzIEEE802.11a/n on 5GHzIEEE802.3atPower RequirementsExternal Power AdapterDC IN, 12V/2A
AntennaFour/Six* Internal 5 dBi Omni-Directional AntennasNote: EWS310AP has four antennas; EWS320AP has six antennas.SecurityWEP (64/128bit)WPA/WPA2(TKIP/AES)Hidden ESSIDMAC address filtering, up to 50 fieldsL2 Isolation802.1X Authenticator (MD5/TLS/TTLS/PEAP)Guest Network
Physical Interface1 x 10/100/1000 Gigabit Ethernet Port1 x Reset Button1 x Power ConnectorQoS (Quality of Service)WMM (Wireless Multimedia)
LED IndicatorPowerWLAN (Wireless Connection)LANMeshPhysical/Environment ConditionsOperating:Temperature: 32°F to 104°F (-0°C to 40°C)Humidity (Non-condensing): 90% or lessStorage:Temperature: -4°F to 140°F (-20°C to 60°C)Humidity (Non-condensing): 90% or less

Physical Interface

Dimensions and Weights

Diameter: 6.36"

Height: 2.17"

EnGenius 1 2

ENGENIUS EWS300AP - Dimensions and Weights - 2

natural_image 3D rendering of a white electronic device casing with labeled ports (no text or symbols beyond numbered labels)
  1. Reset Button: Press and hold for over 10 seconds to reset to factory default settings.
  2. LED Indicators: LED lights for Mesh, WLAN 5GHz, WLAN 2.4GHz, Ethernet port, and Power
  3. LAN Port (802.3at PoE): Ethernet port for RJ-45 cable.
  4. Power Connector: 12V DC IN for Power.
  5. Ceiling (Wall) Mount Hole: Using the provided hardware, the EWS310AP/EWS320AP can be attached to a ceiling or wall.
  6. Kensington Security Slot: To protect your EWS310AP/EWS320AP, use the Kensington Security Slot to attach a cable lock.

Chapter 2

Before You Begin

ENGENIUS EWS300AP - Before You Begin - 1

natural_image White EnGenius wireless router device with no visible text or symbols on the body

Before You Begin

This section will guide you through the installation process. Placement of the EnGenius EWS310AP/EWS320AP essential to maximize the Access Point's performance. Avoid placing the EWS310AP/EWS320AP in an enclosed space such as a closet, cabinet, or stairwell.

Considerations for Wireless Installation

The operating distance of all wireless devices can often not be pre-determined due to a number of unknown obstacles in the environment in which the device is deployed. Obstacles such as the number, thickness, and location of walls, ceilings, or other objects that the EWS310AP/EWS320AP's wireless signals must pass through can weaken the signal. Here are some key guidelines for allowing the EWS310AP/EWS320AP to have an optimal wireless range during setup.

  • Keep the number of walls and/or ceilings between the EWS310AP/EWS320AP and other network devices to a minimum. Each wall and/or ceiling can reduce the signal strength, resulting in a lower overall signal strength.
  • Building materials make a difference. A solid metal door and/or aluminum stubs may have a significant negative effect on the signal strength of the EWS310AP/EWS320AP. Locate your wireless devices carefully so the signal can pass through drywall and/or open doorways. Materials such as glass, steel, metal, concrete, water (example: fish tanks), mirrors, file cabinets, and/or brick can also diminish wireless signal strength.
  • Interference from your other electrical devices and/or appliances that generate RF noise can also diminish the EWS310AP/EWS320AP's signal strength. The most common types of devices are microwaves or cordless phones.

Computer Settings

Windows XP/Windows 7

In order to use the EWS310AP/EWS320AP, you must first configure the TCP/IPv4 connection of your Windows OS computer system.

1. Click the Start button and open the Control Panel

Administrator My Documents My Recent Documents > My Pictures My Music My Computer Control Panel Set Program Access and Defaults Connect To Printers and Faces Help and Support Search Run... All Programs Log Off Turn Off Computer

Windows XP

Internet Explorer Tera Term Pro Command Prompt Notepad Wireshop InChardt Console Point CCleaner Word/Pad 7-Zip File Manager EnGenus Wireless Utility Mozilla Firefox All Programs Search programs and files Control Panel Devices and Printers Run...

Windows 7

2a. In Windows XP, click on Network Connections.

ENGENIUS EWS300AP - Click the Start button and open the Control Panel - 3

2b. In Windows 7, click View network status and tasks in the Network and Internet section, then select Change adapter

settings.

ENGENIUS EWS300AP - settings. - 1

Network and Internet

View network status and tasks

Choose homegroup and sharing options

Control Panel Home

Change adapter settings

Change advanced sharing settings

  1. Right click oLocal Area Connection and select Properties

  2. Select Internet Protocol Version 4 (TCP/IPv4) then select Properties

ENGENIUS EWS300AP - settings. - 2

Local Area Connection

Disable Status Repair

Bridge Connections

Create Shortcut Delete Rename

Properties

Client for Microsoft Networks QoS Packet Scheduler File and Printer Sharing for Microsoft Networks Internet Protocol Version 6 (TCP/IPv6) Internet Protocol Version 4 (TCP/IPv4) Link-Layer Topology Discovery Mapper I/O Driver Link-Layer Topology Discovery Responder Install... Uninstall Properties

  1. SelectUse the following IP address and enter an IP address that is different from the EWS310AP/EWS320AP and Subnet mask, then cOK.

Note: Ensure that the IP address and Subnet mask are on the same subnet as the device.

For example: EWS310AP/EWS320AP IP address: 192.168.1.1

PC IP address: 192.168.1.2 - 192.168.1.255

PC Subnet mask: 255.255.255.0

Apple Mac OS X

  1. Go to System Preferences(it can be opened in theApplications folder or by electing it in the Apple Menu).
  2. Select Network in the Internet & Network section.

System Preferences Show All Personal Appearance Desktop & Screen Saver Dock Expose & Spaces International Securit Hardware Bluetooth CDs & DVDs Displays Energy Saver Keyboard & Mouse Print & Internet & Network .Mac Network QuickTime Sharing System

  1. HighlightEthernet.
  2. In Configure IPv4 select Manually.
  3. Enter an IP address that is different from the EWS310AP/EWS320AP and Subnet mask, then clickOK.

Note: Ensure that the IP address and Subnet mask are on the same subnet as the device.

For example: EWS310AP/EWS320AP IP address: 192.168.1.1

PC IP address: 192.168.1.2 - 192.168.1.255

PC Subnet mask: 255.255.255.0

  1. Click Apply when finished.

Network Show All Location: Automatic Ethernet Connected FireWire Not Connected Status: Connected Ethernet is currently active and has the IP address 192.168.1.100. Configure IPv4: Manually IP Address: 192.168.1.100 Subnet Mask: 255.255.255.0 Router: DNS Server: Search Domains: Advanced... Click the lock to prevent further changes. Assist me... Revert Apply

Hardware Installation

  1. Ensure that the computer in use has an Ethernet Controller port (RJ-45 Ethernet Port). For more information, verify with your computer's user manual.
  2. Connect one end of the Category 5e Ethernet cable into the RJ-45 port of the EWS310AP/EWS320AP and the other end to the RJ-45 port of the computer. Ensure that the cable is securely connected to both the EWS310AP/EWS320AP and the computer.
  3. Connect the Power Adapter DC connector to the DC-IN port of the EWS310AP/EWS320AP and the Power Adapter to an available electrical outlet. Once both connections are secure, verify the following:
    a) Ensure that the POWER light is on (it will beorange).
    b) Ensure that the 2.4 GHz/5 GHz WLAN light is on (it will be blue for 2.4G, and green for 5G).
    c) Ensure that the LAN (Computer/EWS310AP/EWS320AP Connection) light is on (it will be blue).
    d) Once all three lights are on, proceed to set up the Access Point using the computer.

This diagram depicts the hardware configuration.

ENGENIUS EWS300AP - Hardware Installation - 1

flowchart
graph TD
    A["Desktop"] --> B["Server"]
    B --> C["Network Device"]
    C --> D["User Interface"]

Mounting the EWS310AP/EWS320AP

Using the provided hardware, the EWS310AP/EWS320AP can be attached to a ceiling or wall.

To attach the EWS310AP/EWS320AP to a ceiling or wall using the mounting bracket:

  1. Attach the mounting bracket to the wall or ceiling using the provided wall/ceiling mounting hardware kit.

  2. Insert the provided short screws into the bottom cover of the EWS310AP/EWS320AP.

Leave enough of the screws exposed to ensure that the unit can be attached to the mounting bracket.

If extra space is required, use the provided spacers and long screws from the T-Rail mounting hardware kit to increase the space between the unit and the mounting bracket.

Wall Mounting Screw Mounting Bracket P3.5°32 Screw P2.6°12 Screw To lock the EWS310AP/EWS320AP by revolving

  1. Mount the EWS310AP/EWS320AP on the mounting bracket by rotating the unit clockwise about 90 degrees to secure it in place.

Attaching the EWS310AP/EWS320AP to a ceiling using the provided T-Rail connectors:

  1. Attach the T-Rail connectors to the bottom cover of the EWS310AP/EWS320AP using the provided short screws.

Note: Two sizes of T-Rail connectors are included in the mounting hardware kit: 15/16in (2.38cm) and 9/16in (1.43cm). If extra space is required to accommodate drop ceiling tiles, use the provided spacers and long screws.

P2.6°10 Screw Clip P2.6°25 Screw Clip Spacer

  1. Line up the connected T-Rail connectors with an appropriately sized rail and press the unit onto the rail until it snaps into place.

T rail Clip

Note: To protect your EWS310AP/EWS320AP, use the Kensington Security Slot to attach a cable lock (cable lock is not included).

Chapter 3

Configuring Your Access Point

ENGENIUS EWS300AP - Configuring Your Access Point - 1

natural_image Exterior view of a white EnGenius wireless router device (no visible text or symbols on the device body)

Configuring Your Access Point

This section will show you how to configure the device using the web-based configuration interface.

Default Settings

Please use your Ethernet port or wireless network adapter to connect the Access Point.

IP Address192.168.1.1
Username/Passwordadmin/admin

Web Configuration

  1. Open a web browser (Internet Explorer/Firefox/Safari) and enter the IP Address http://192.168.1.1.

Blank Page - Windows Internet Explorer http://192.168.1.1

Note: If you have changed the default LAN IP Address of the Access Point, ensure you enter the correct IP Address.

  1. The default username and password are: admin. Once you have entered the correct username and password, click the Login button to open the web-based configuration page.

EnGenius® EWS320AP Password Login Copyright © 2015 EnGenius® All rights reserved.

  1. If successful, you will be logged in and see the EWS310AP/EWS320AP User Menu.

EnGenius®

EWS320AP

Dual Radio AP, 3T3R, 450Mbps + 450Mbps

Changes: 0

Reset

Logout

ENGENIUS EWS300AP - EnGenius® - 1

Overview

Device Status

Connections

ENGENIUS EWS300AP - Overview - 1

Network

Basic

Wireless

ENGENIUS EWS300AP - Network - 1

Management

Advanced

Time Zone

WiFi Scheduler

Tools

ENGENIUS EWS300AP - Management - 1

System Manager

Account

Firmware

Log

Device Information

Device NameEWS320AP
MAC Address
- LAN88:DC:96:05:B0:68
- Wireless LAN - 2.4GHz88:DC:96:05:B0:69
- Wireless LAN - 5GHz88:DC:96:05:B0:6A
CountryDefault
Current Local TimeTue Jan 7 07:56:35 UTC 2014
Firmware Version2.0.0
Management VLAN ID4096

LAN Information - IPv4

IP Address192.168.1.1
Subnet Mask255.255.255.0
Gateway192.168.1.1
Primary DNS0.0.0.0
Secondary DNS0.0.0.0

Chapter 4

Overview

Overview

The Overview section contains the following options:

  • Device Status
  • Connections

The following sections describe these options.

Device Status

Clicking the Device Statuslink under theOverview menu shows the status information about the current operating mode.

- The Device Information section shows general system information such as Device Name, MAC address, Current Time, Firmware Version, and Management VLAN ID

Device Information

Device NameEWS320AP
MAC Address
- LAN88:DC:96:05:B0:68
- Wireless LAN - 2.4GHz88:DC:96:05:B0:69
- Wireless LAN - 5GHz88:DC:96:05:B0:6A
CountryDefault
Current Local TimeTue Jan 7 07:56:35 UTC 2014
Firmware Version2.0.0
Management VLAN ID4096

- The LAN Information section shows the Local Area Network settings such as the LAN IP Address, Subnet mask, Gateway, DNS Address, DHCP Client, and STP status.

LAN Information - IPv4

IP Address192.168.1.1
Subnet Mask255.255.255.0
Gateway192.168.1.1
Primary DNS0.0.0.0
Secondary DNS0.0.0.0
DHCP ClientDisable
Spanning Tree Protocol (STP)Disable

LAN Information - IPv6

IP AddressN/A
Link-Local Addressfe80:8adc:96ff.fe05 b068
GatewayN/A
Primary DNSN/A
Secondary DNSN/A

- The Wireless LAN Information 2.4 GHz/5GHz section shows wireless information such as Operating Mode, Frequency, and Channel. Since the EWS310AP/EWS320AP supports multiple-SSIDs, information about each SSID and security settings are displayed.

Wireless LAN Information - 2.4GHz

Operation ModeAP
Wireless Mode802.11 B/G/N
Channel Bandwidth20-40 MHz
Channel2.412 GHz (Channel 1)
ProfileSSIDSecurityVID802.1Q
#1EnGenius05B069_1-2.4GHzNone1Disable
#2EnGenius05B069_2-2.4GHzNone2Disable
#3EnGenius05B069_3-2.4GHzNone3Disable
#4EnGenius05B069_4-2.4GHzNone4Disable
#5EnGenius05B069_5-2.4GHzNone5Disable
#6EnGenius05B069_6-2.4GHzNone6Disable
#7EnGenius05B069_7-2.4GHzNone7Disable
#8EnGenius05B069_8-2.4GHzNone8Disable

Wireless LAN Information - 5GHz

Operation ModeAP
Wireless Mode802.11 A/N
Channel Bandwidth40 MHz
Channel5.66 GHz (Channel 132)
ProfileSSIDSecurityVID802.1Q
#1EnGenius05B06A_1-5GHzNone51Disable
#2EnGenius05B06A_2-5GHzNone52Disable
#3EnGenius05B06A_3-5GHzNone53Disable
#4EnGenius05B06A_4-5GHzNone54Disable
#5EnGenius05B06A_5-5GHzNone55Disable
#6EnGenius05B06A_6-5GHzNone56Disable
#7EnGenius05B06A_7-5GHzNone57Disable
#8EnGenius05B06A_8-5GHzNone58Disable

Connections

Clicking the Connections link under the Device Status menu displays the list of clients associated to the EWS310AP/EWS320AP's 2.4GHz/5GHz, along with the MAC address, TX, RX and signal strength for each client. Clicking Kick in the Block column removes this client.

Connection List - 2.4GHz

SSIDMAC AddressTXRXRSSIBlock
Connection List - 5GHz
SSIDMAC AddressTXRXRSSIBlock
EnGenius05B06A_1-5GHz00:02:6F:93:47:5C162Kb30Kb-42dBmKick

Refresh

Click Refresh to refresh the Connection List page.

Chapter 5

Network

ENGENIUS EWS300AP - Network - 1

natural_image White EnGenius wireless router device with indicator lights (no visible text or symbols on body)

Basic

This page allows you to modify the device's IP settings and the Spanning Tree settings. Enabling Spanning Tree protocol will prevent network loops in your LAN network.

IPv4 Settings

IPv4 Settings

IP Network Setting○ DHCP ● Static IP
IP Address192.168.1.1
Subnet Mask255.255.255.0
Gateway192.168.1.1
Primary DNS0.0.0.0
Secondary DNS0.0.0.0

IP Network Setting: Select whether the device IP address will use the static IP address specified in the IP Address field or be obtained automatically when the device connects to a DHCP server.

IP Address The IP Address of this device.

IP Subnet Mask The IP Subnet mask of this device.

Gateway: The Default Gateway of this device. Leave it blank if you are unsure of this setting.

Primary/Secondary DNS The primary/secondary DNS address for this device.

IPv6 Settings

IPv6 SettingsLink-local Address
IP Address
Subnet Prefix Length
Gateway
Primary DNS
Secondary DNS

Link-Local Address Check this if you want to use Link-Local Address.

IP Address The IPv6 IP Address of this device.

Subnet Prefix Length The IPv6 Subnet Prefix Length of this device.

Gateway: The IPv6 Default Gateway of this device. Leave it blank if you are unsure of this setting.

Primary / Secondary DNS The primary / secondary DNS address for this device.

Spanning Tree Settings

Spanning Tree Protocol (STP) Settings

Status○ Enable ● Disable
Hello Time2seconds (1-10)
Max Age20seconds (6-40)
Forward Delay4seconds (4-30)
Priority32768(0-65535)

Save

Save current setting(s)

Status: Enables or disables the Spanning Tree function.

Hello Time Specify Bridge Hello Time, in seconds. This value determines how often the device sends handshake packets to communicate information about the topology throughout the entire Bridged Local Area Network.

Max Age: Specify Bridge Max Age, in seconds. If another bridge in the spanning tree does not send a hello packet for a long period of time, it is assumed to be inactive.

Forward Delay: Specifies Bridge Forward Delay, in seconds. Forwarding Delay Time is the time spent in each of the Listening and Learning states before the Forwarding state is entered. This delay is provided so that when a new bridge comes onto a busy network, it analyzes data traffic before participating.

Priority: Specify the Priority Number. A smaller number has greater priority.

Save: Click Save to confirm the changes.

Chapter 6

2.4GHz & 5GHz Wireless

ENGENIUS EWS300AP - 2.4GHz &amp; 5GHz Wireless - 1

natural_image Exterior view of a white EnGenius wireless router device (no visible text or symbols on the device body)

Wireless Network

This page displays the current status of the Wireless settings of the EWS310AP/EWS320AP.

Wireless Settings

Wireless Settings

Device NameEWS320AP
Country / RegionPlease Select a Country Code
Band Steering○ Enable ● DisableNOTE: In order for Band Steering function to work properly, both 2.4GHz and 5GHz SSID and Security Settings must be the same.

Device Name: Enter a name for the device. The name you type appears in SNMP management. This name is not the SSID and is not broadcast to other devices.

Country/Region: Select a Country/Region to conform to local regulations.

Band Steering: Enable Band Steering to sends 802.11n clients to the 5GHz band, where 802.11b/g clients cannot go, and leaves the 802.11b/g clients in 2.4GHz to operate at their slower rates. Band Steering works within the Access Point by directing 5GHz-capable clients to that band.

*Note: In order for the Band Steering function to work properly, both the 2.4GHz and the 5GHz SSID and security settings must be under the same selection settings.

2.4GHz5GHz
Operation ModeAccess Point√□ Green√Access Point√□ Green√
Wireless Mode802.11 B/G/N802.11 A/N
Channel HT Mode20/40 MHz40 MHz
Extension ChannelUpper ChannelLower Channel
ChannelAutoAuto
Transmit PowerAutoAuto
Data RateAutoAuto
RTS / CTS Threshold (1 - 2346)23462346
Client Limits127● Enable ○ Disable127● Enable ○ Disable
Aggregation● Enable ○ Disable● Enable ○ Disable
32Frames32Frames
50000Bytes(Max)50000Bytes(Max)
AP DetectionScanScan

Wireless Mode: Supports 802.11b/g/n mixed mode in 2.4GHz and 802.11a/n mixed mode in 5GHz.

Channel HT Mode: The default channel bandwidth is 20/40MHz. The larger the channel bandwidth, the better the transmission quality and speed. This option is only available for 802.11n modes only.

Extension Channel: Use the drop-down menu to set the Extension Channel as Upper or Lower channel. An extension channel is a secondary channel used to bond with the primary channel to increase this range to 40MHz allowing for greater bandwidth. This option is only available when Wireless Mode is 802.11n and Channel HT Mode is 20/40 MHz or 40MHz.

Channel: Select the channel appropriate for your country's regulation.

Transmit Power: Select the transmit power for the radio. Increasing the power improves performance, but if two or more access points are operating in the same area on the same channel, it may cause interference.

Data Rate: Use the drop-down list to set the available transmit data rates permitted for wireless clients. The data rate affects the throughput of the access point. The lower the data rate, the lower the throughput, but the longer transmission distance.

RTS/CTS Threshold: Specifies the threshold package size for RTC/CTS. A small number causes RTS/CTS packets to be sent more often and consumes more bandwidth.

Client Limits: Limits the total number of clients.

Aggregation: Merges data packets into one packet. This option reduces the number of packets, but also increases packet sizes.

AP Detection: AP Detection can select the best channel to use by scanning nearby areas for Access Points.

2.4GHz/5GHz SSID Profile

Under Wireless Settings you can edit the SSID profile to fit your needs. ClickEdit under the SSID you would like to make changes to.

Wireless Settings - 2.4GHz

No.EnableSSIDEditSecurityHidden SSIDClient IsolationVLAN IsolationVLAN ID
1EnGenius05B069_1-2.4GHzEditNone1
2EnGenius05B069_2-2.4GHzEditNone2
3EnGenius05B069_3-2.4GHzEditNone3
4EnGenius05B069_4-2.4GHzEditNone4
5EnGenius05B069_5-2.4GHzEditNone5
6EnGenius05B069_6-2.4GHzEditNone6
7EnGenius05B069_7-2.4GHzEditNone7
8EnGenius05B069_8-2.4GHzEditNone8

Wireless Settings - 5GHz

No.EnableSSIDEditSecurityHidden SSIDClient IsolationVLAN IsolationVLAN ID
1EnGenius05B06A_1-5GHzEditNone51
2EnGenius05B06A_2-5GHzEditNone52
3EnGenius05B06A_3-5GHzEditNone53
4EnGenius05B06A_4-5GHzEditNone54
5EnGenius05B06A_5-5GHzEditNone55
6EnGenius05B06A_6-5GHzEditNone56
7EnGenius05B06A_7-5GHzEditNone57
8EnGenius05B06A_8-5GHzEditNone58

Enable: Check this option to enable this profile.

SSID: Specifies the SSID for the current profile.

Security: Displays the Security Mode the SSID uses. You can click Edit to change the security mode. For more details, see the next section.

Hidden SSID: Check this option to hide the SSID from clients. If checked, the SSID will not appear in the site survey.

Client Isolation: Check this option to prevent communication between client devices.

VLAN Isolation: Check this option to enable VLAN Isolation feature.

VLAN ID: Specifies the VLAN ID for the SSID profile.

Wireless Security

The Wireless Security section lets you configure the EWS310AP/EWS320AP's security modes: WEP, WPA-PSK, WPA2-PSK, WPA-PSK Mixed, WPA-Enterprise, WPA2-Enterprise and WPA Mixed Enterprise.

It is strongly recommended that you use WPA2-PSK. Click on the Edit button under Wireless Settings next to the SSID to change the security settings.

WEP

Security ModeWEP
Auth TypeOpen System
Input TypeHex
Key Length40/64-bit (10 hex digits or 5 ASCII char)
Default Key1
Key1
Key2
Key3
Key4

Auth Type: Select Open System or Shared Key.

Input Type: ASCII: Regular Text (Recommended) or HEX: Hexadecimal Numbers (For advanced users).

Key Length: Select the desired option and ensure the wireless clients use the same setting. Your choices are: 64, 128, and 152-bit password lengths.

Default Key: Select the key you wish to be default. Transmitted data is ALWAYS encrypted using the Default Key; the other Keys are for decryption only. You must enter a Key Value for the Default Key.

Encryption Key: Enter the Key Value or values you wish to use. The default is none.

WPA-PSK/WPA2-PSK (Pre-Shared Key)

Security ModeWPA-PSK Mixed
EncryptionBoth(TKIP+AES)
Passphrase
Group Key Update Interval3600

Encryption: Select the WPA/WPA2 encryption type you would like to use. Available options are Both, TKIP(Temporal Key Integrity Protocol) and AES(Advanced Encryption Standard). Please ensure that your wireless clients use the same settings.

Passphrase: Wireless clients must use the same Key to associate the device. If using ASCII format, the Key must be from 8 to 63 characters in length. If using HEX format, the Key must be 64 HEX characters in length.

Group Key Update Interval: Specify how often, in seconds, the Group Key changes.

WPA/WPA2-Enterprise

Security ModeWPA Mixed-Enterprise
EncryptionBoth(TKIP+AES)
Group Key Update Interval3600
Radius Server
Radius Port1812
Radius Secret
Radius AccountingDisable
Radius Accounting Server
Radius Accounting Port1813
Radius Accounting Secret
Interim Accounting Interval600

Encryption: Select the WPA/WPA2 encryption type you would like to use. Available options are Both, TKIP(Temporal Key Integrity

Protocol) and AES(Advanced Encryption Standard). Please ensure that your wireless clients use the same settings.

Group Key Update Interval: Specify how often, in seconds, the group key changes.

Radius Server: Enter the IP address of the Radius server.

Radius Port: Enter the port number used for connections to the Radius server.

Radius Secret: Enter the secret required to connect to the Radius server.

Radius Accounting: Enables or disables the accounting feature.

Radius Accounting Server: Enter the IP address of the Radius accounting server.

Radius Accounting Port: Enter the port number used for connections to the Radius accounting server.

Radius Accounting Secret: Enter the secret required to connect to the Radius accounting server.

Interim Accounting Interval Specify how often, in seconds, the accounting data sends.

Note: 802.11n does not allow WEP/WPA-PSK TKIP/WPA2-PSK TKIP security mode. The connection mode will automatically change from 802.11n to 802.11g.

Wireless MAC Filter

Wireless MAC Filter is used to allow or deny network access to wireless clients (computers, tablet PCs, NAS, smart phones, etc.) according to their MAC addresses. You can manually add a MAC address to restrict permission to access EWS310AP/EWS320AP. The default setting is: Disable Wireless MAC Filter.

Wireless MAC Filter
ACL Mode Disabled Add No. MAC Address

ACL (Access Control List) Mode: Determines whether network access is granted or denied to clients whose MAC addresses appear in the MAC address table on this page. Choices given are: Disabled, Deny MAC in the list, or Allow MAC in the list.

MAC Address: Enter the MAC address of the wireless client.

Add: Click Add to add the MAC address to the MAC Address table.

Delete: Deletes the selected entries.

Traffic Shaping

Traffic Shaping regulates the flow of packets leaving an interface to deliver improved Quality of Service.

Wireless Traffic Shaping

Enable Traffic Shaping○ Enable● Disable
Download Limit100Mbps (1-999)
Upload Limit100Mbps (1-999)

Save

Save current setting(s)

Enable Traffic Shaping: Select to Enable or Disable Wireless Traffic Shaping.

Download Limit: Specifies the wireless transmission speed used for downloading.

Upload Limit: Specifies the wireless transmission speed used for uploading.

Save: Click Save to apply the changes.

Guest Network

The Guest Network function allows administrators to grant Internet connectivity to visitors or guests while keeping other networked devices (computers and hard drives) and sensitive personal or company information private and secure.

Guest Network Settings

EnableSSIDEditSecurityHidden SSIDClient Isolation
EnGenius-2.4GHz_GuestNetwEditNone
EnGenius-5GHz_GuestNetwoEditNone

Enable SSID: Select to Enable or Disable SSID broadcasting.

SSID: Specify the SSID for the current profile. This is the name visible on the network to wireless clients.

Security: You can use None or WPA-PSK / WPA2-PSK security for this guest network.

Hidden SSID: Check this option to hide the SSID from broadcasting to discourage wireless users from connecting to a particular SSID.

Client Isolation: Check this option to prevent wireless clients associated with your access point to communicate with other wireless devices connected to the AP.

After enabling Guest Network in the SSID Config page, assign an IP Address, Subnet Mask and DHCP server IP address range for this Guest Network.

Manual IP Settings
- IP Address192.168.200.1
- Subnet Mask255.255.255.0
Automatic DHCP Server Settings
- Starting IP Address192.168.200.100
- Ending IP Address192.168.200.200
- WINS Server IP0.0.0.0

Manual IP Settings

IP Address: Specify an IP Address for the Guest Network

Subnet Mask: Specify the the Subnet Mask IP Address for the Guest Network

Automatic DHCP Server Settings

Starting IP Address: Specify the starting IP Address range for the Guest Network.

Ending IP Address: Specify the ending IP Address range for the Guest Network.

WINS Server IP: Specify the WINS Server IP Address for the Guest Network. WINS means Windows Internet Name Service. It is Microsoft's implementation of NetBIOS Name Service (NBNS), a name server and service for NetBIOS computer names.

Fast Handover

With Fast Handover enabled, the AP will send a disassociation request to the wireless client and let it find another AP to handover and associate upon detecting the wireless client's RSSI value lower than specified. The RSSI value can be adjusted to allow more clients to stay associated to this AP. Note that setting the RSSI value too low may cause wireless clients to reconnect frequently.

Fast Handover

Status○ Enable● Disable
RSSI-70dBm (Range: -60dBm ~ -90dBm)

Management VLAN Settings

This section allows you to assign a VLAN tag to the packets. A VLAN is a group of computers on a network whose software has been configured so that they behave as if they were on a separate Local Area Network (LAN). Computers on VLAN do not have to be physically located next to one another on the LAN.

Management VLAN Settings

Status

○ Enable

● Disable

4096

Caution: If you encounter disconnection issue during the configuration process, verify that the switch and the DHCP server can support the new VLAN ID and then connect to the new IP address.

Save

Save current setting(s)

Status: If your network includes VLANs and if tagged packets need to pass through the Access Point, select Enable and enter the VLAN ID. Otherwise, click Disable.

Save: Click Save to apply the changes.

Note: If you reconfigure the Management VLAN ID, you may lose your connection to the EWS310AP/EWS320AP. Verify that the DHCP server supports the reconfigured VLAN ID and then reconnect to the EWS310AP/EWS320AP using the new IP address.

Chapter 7

Management

ENGENIUS EWS300AP - Management - 1

natural_image White EnGenius 3D router device with control buttons and indicator lights (no visible text or symbols on body)

SNMP Settings

This page allows you to assign the Contact Details, Location, Community Name, and Trap Settings for Simple Network Management Protocol (SNMP). This is a networking management protocol used to monitor network attached devices. SNMP allows messages (called protocol data units) to be sent to various parts of the network. Upon receiving these messages, SNMP compatible devices (called agents) returns the data stored in their Management Information Bases. To configure SNMP Settings, click under Advanced tab on the side bar under Management

SNMP Settings

Status● Enable ○ Disable
Contact
Location
Port161
Community Name (Read Only)public
Community Name (Read Write)private
Trap Destination
- Port162
- IP Address
- Community Namepublic
SNMPv3 Settings
- Status● Enable ○ Disable
- Usernameadmin(1-31 Characters)
- Authorized ProtocolMD5
- Authorized Key12345678(8-32 Characters)
- Private ProtocolDES
- Private Key12345678(8-32 Characters)
- Engine ID

Status: Enables or Disables the SNMP feature.

Contact: Specifies the contact details of the device.

Location: Specifies the location of the device.

Port: Displays the port number.

Community Name (Read Only): Specifies the password for the SNMP community for read only access.

Community Name (Read/Write): Specifies the password for the SNMP community with read/write access.

Trap Destination Address: Specifies the port and IP address of the computer that will receive the SNMP traps.

Trap Destination Community Name Specifies the password for the SNMP trap community.

SNMPv3 Status: Enables or Disables the SNMPv3 feature.

User Name: Specifies the username for the SNMPv3.feature

Auth Protocol: Select the Authentication Protocol type: MDS or SHA.

Auth Key: Specify the Authentication Key for authentication.

Priv Protocol: Select the Privacy Protocol type: DES.

Priv Key: Specifies the privacy key for privacy.

Engine ID: Specifies the Engine ID for SNMPv3.

CLI/SSH Settings

Most users will configure the device through the graphical user interface (GUI). However, for those who prefer an alternative method there is the command line interface (CLI). The CLI can be access through a command console, modem or Telnet connection. For security's concern, you can enable SSH (Secure Shell) to establish a secure data communication.

CLI Setting

Status● Enable ○ Disable
SSH Setting
Status○ Enable ● Disable

CLI Status: Select Enable or Disable to enable or disable the ability to modify the EWS310AP/EWS320AP via a command line interface (CLI).

SSH Status: Select Enable or Disable to enable or disable the ability to modify the EWS310AP/EWS320AP via a command line interface (CLI) with a secure channel.

HTTPS Settings

Hypertext Transfer Protocol Secure (HTTPS) is a communications protocol for secure communication over a computer network, with especially wide deployment on the Internet. Technically, it is not a protocol in and of itself; rather, it is the result of simply layering the Hypertext Transfer Protocol (HTTP) on top of the SSL/TLS protocol, thus adding the security capabilities of SSL/TLS to standard HTTP communications.

HTTPS Settings

Status● Enable ○ Disable
HTTPS forward○ Enable ● Disable

Status: Select Enable or Disable to enable or disable the ability to modify the EWS310AP/EWS320AP via a HTTPS. HTTPS forward: Enable this option; it will be forwarded to HTTPS if user uses HTTP to access EWS310AP/EWS320AP.

Email Alert

EWS310AP/EWS320AP will send email alerts when EWS310AP/EWS320AP's configuration has been changed.

Email Alert
Status Enable - From To - Subject [Email-Alert][EWS320AP][88:DC:96:05:B0:68] Configur Email Account - Username - Password - SMTP Server Port: 25 - Security Mode None Send Test Mail Apply Apply saved settings to take effect

Status: Check Enable to enable Email Alert feature.

From: Enter the address to show as the sender of the email.

To: Enter the address to show as the receiver of the email.

Subject: Enter the subject to show as the subject of the email.

Email Account

Username/Password: Enter the username and password required to connect to the SMTP server.

SMTP Server/Port: Enter the IP address/domain name and port of the SMTP server. The default port of SMTP Server is port 25.

Security Mode Select the mode of security for the Email alert. The options are None, SSL/TLS and STARTTLS.

Send Test Mail: Click Send Test Mailbutton to test the Email Alert setup.

Apply: Click Apply to save the changes.

Date and Time Settings

This page allows you to set the internal clock of the EWS310AP/EWS320AP. To access the Date and Time settings, click Time Zone under the Management tab on the side bar.

Date and Time Settings

○ Manually Set Date and Time

Date:2014/01/07
Time:11:16(24-Hour)
Synchronize with PC

- Automatically Get Date and Time

NTP Server: 209.81.9.7

Time Zone

Time Zone: UTC+00:00 Gambia, Liberia, Morocco

□ Enable Daylight Saving

Start:January1stSun12 am
End:January1stMon12 am

Apply

Apply saved settings to take effect

Manually Set Date and Time: Manually specify the date and time.

Synchronize with PC: Click to Synchronize the EWS310AP/EWS320AP with the computer's internal clock.

Automatically Get Date and Time: Enter the IP address of an NTP server or use the default NTP server to have the internal clock set automatically.

Time Zone: Choose the time zone you would like to use from the drop-down list.

Enable Daylight Savings: Check the box to enable or disable daylight savings time for the EWS310AP/EWS320AP. Next, enter the dates that correspond to the present year's daylight savings time.

Click Apply to save the changes.

WiFi Scheduler

Use the schedule function to reboot EWS310AP/EWS320AP or control the wireless availability on a routine basis. The Schedule function relies on the GMT time setting acquired from a network time protocol (NTP) server. For details on how to connect the EWS310AP/EWS320AP to an NTP server, see Date and Time Settings.

Auto Reboot Settings

You can specify how often you would like to reboot the EWS310AP/EWS320AP.

Auto Reboot Settings

Status○ Enable ● Disable
Timer□ Sunday □ Monday □ Tuesday □ Wednesday □ Thursday □ Friday □ Saturday
0 : 0

Status: Enables or disables the Auto Reboot function.

Timer: Specifies the time and frequency in rebooting the EWS310AP/EWS320AP by Min, Hour and Day.

WiFi Scheduler

Wi-Fi Scheduler

Status○ Enable ● DisableNOTE: Please assure that the Time Zone Settings is synced with your local time when enabling the Wi-Fi Scheduler.
Wireless Radio2.4GHz√
SSID SelectionEnGenius05B069_1-2 4GHz√
Schedule TemplatesChoose a template √
Schedule TableDayAvailabilityDuration
Sundayavailable √00: 00~ 24: 00
Mondayavailable √00: 00~ 24: 00
Tuesdayavailable √00: 00~ 24: 00
Wednesdayavailable √00: 00~ 24: 00
Thursdayavailable √00: 00~ 24: 00
Fridayavailable √00: 00~ 24: 00
Saturdayavailable √00: 00~ 24: 00

Save

Save current setting(s)

Status: Enables or disables the WiFi Scheduler function.

Wireless Radio: Select 2.4GHz or 5GHz to use WiFi Schedule.

SSID Selection: Select a SSID to use WiFi Schedule.

Schedule Templates: EWS310AP/EWS320AP provides three templates: Always available, Available 8-5 daily and Available 8-5 daily except weekends. Select Custom schedule if you want to set the schedule manually.

Schedule Table: Set the schedule manually.

Tools

This section allows you to analyze the connection quality of the EWS310AP/EWS320AP and trace the routing table to a target in the network.

Ping Test Parameters

Ping Test Parameters

Target IP / Domain Name
Ping Packet Size64Bytes
Number of Pings4
Start

Target IP/Domain Name: Enter the IP address or Domain name you would like to search.

Ping Packet Size: Enter the packet size of each ping.

Number of Pings: Enter the number of times you wish to ping.

Start: Click Start to begin pinging target device (via IP).

Traceroute Parameters

Traceroute Test Parameters
Target IP / Domain Name Start Stop

Target IP/Domain Name: Enter an IP address or domain name you wish to trace.

Start: Click Start to begin the trace route operation.

Stop: Halts the traceroute test.

Speed Test Parameters

Speed Test Parameters

Target IP / Domain Name
Time Period20sec
Check Interval5sec
Start
<>
IPv4 Port5001
IPv6 Port5002

Target IP/Domain Name: Enter an IP address or domain name you wish to run a Speed Test for.

Time Period : Enter the time in seconds that you would like the test to run for and in how many intervals.

Start: Starts the Speed Test.

IPv4 / IPv6 Port: EWS310AP/EWS320AP uses IPv4 port 5001 and IPv6 port 5002 for the speed test.

LED Control

This section allows you to control the LED control functions: Power status, LAN interface and 2.4GHz/5GHz WLAN interface.

LED Control

Power● Enable ○ Disable
LAN● Enable ○ Disable
WLAN-2.4GHz● Enable ○ Disable
WLAN-5GHz● Enable ○ Disable
ApplyApply saved settings to take effect

Click Apply to save the settings after selecting your choices from the boxes.

Device Discovery

Under Device Discovery, you can choose for the EWS310AP/EWS320AP to automatically scan for local devices to connect to. Click Scan to begin the process.

Device Discovery

Device NameOperation ModeIP AddressSystem MAC AddressFirmware Version
Scan

Chapter 8

System Manager

ENGENIUS EWS300AP - System Manager - 1

natural_image White EnGenius 3D router device with control buttons and indicator lights (no visible text or symbols on body)

Account Setting

This page allows you to change the EWS310AP/EWS320AP username and password. By default, the username is admin and the password is admin. The password can contain from 0 to 12 alphanumeric characters and is case sensitive.

Account Settings

Administrator Usernameadmin
Current Password
New Password
Verify Password

Apply

Apply saved settings to take effect

Administrator Username: Enter a new username for logging in to the Administrator Username entry box.

Current Password: Enter the old password for logging in to the Current Password entry box.

New Password: Enter the new password for logging in to the New Password entry box.

Verify Password: Re-enter the new password in the Verify Password entry box for confirmation.

Apply: Click Apply to save the changes.

Note: it is highly recommended that you change your password to something more unique for greater security.

Firmware Upgrade

This page allows you to upgrade the Firmware of the EWS310AP/EWS320AP.

Firmware Upgrade

Current Firmware Version: 2.0.0

Select the new firmware from your hard disk.

ENGENIUS EWS300AP - Firmware Upgrade - 1

To Perform the Firmware Upgrade:

  1. Click theBrowse... button and navigate the OS File System to the location of the Firmware upgrade file.
  2. Select the upgrade file. The name of the file will appear in the Upgrade File field.
  3. Click theUpload button to commence the Firmware upgrade.

Note: The device is unavailable during the upgrade process and must restart when the upgrade is completed. Any connections to or through the device will be lost.

Backup/Restore

This page allows you to save the current device configurations. When you save the configurations, you can also reload the saved configurations into the device through the Restore New Settings from a file folder. If extreme problems occur, or if you have set the EWS310AP/EWS320AP incorrectly, you can use the Reset button in the Reset to Default section to restore all the configurations of the EWS310AP/EWS320AP to the original default settings. To Configure the Backup/Restore Settings, click Firmware under the Systems Manager tab.

Backup/Restore Settings

Factory Setting
- Backup SettingExport
- Restore New SettingBrowse...Import
- Reset to DefaultReset
User Setting
- Back Up Setting as DefaultBackup
- Restore to User DefaultRestore

Factory Setting

Backup Setting: Click Export to save the current device configurations to a file.

Restore New Setting: Choose the file you wish restore for settings and click Import.

Reset to Default: Click the Reset button to restore the EWS310AP/EWS320AP to its factory default settings.

User Setting

Back Up Setting as Default: Click Backup to backup the user settings you would like to use as the default settings. Restore to User Default: Click Restore to restore the EWS310AP/EWS320AP to user's default settings.

System Log

This page allows you to setup the System Log and local log functions of the EWS310AP/EWS320AP. Click Systems Manager tab to open up the System Log page.

Log under the

System Log
Status Enable Disable Log type All Refresh Clear Jan 7 11:20:01 EWS320AP user.notice root: starting ntpd Jan 7 11:20:01 EWS320AP cron.info crond[2159]: crond: USER root pid 3505 cmd sch Jan 7 11:20:01 EWS320AP cron.info crond[2159]: crond: USER root pid 3501 cmd . Jan 7 11:18:01 EWS320AP cron.info crond[2159]: crond: USER root pid 969 cmd sche Jan 7 11:16:01 EWS320AP cron.info crond[2159]: crond: USER root pid 2252 cmd sche Jan 7 11:15:01 EWS320AP user.notice root: starting ntpd Jan 7 11:15:01 EWS320AP cron.info crond[2159]: crond: USER root pid 1011 cmd . Jan 7 11:14:01 EWS320AP cron.info crond[2159]: crond: USER root pid 3582 cmd sche Jan 7 11:12:01 EWS320AP cron.info crond[2159]: crond: USER root pid 954 cmd sche Jan 7 11:10:01 EWS320AP user.notice root: starting ntpd < > Remote Log Enable Disable Log Server IP Address 0.0.0.0

Apply

Apply saved settings to take effect

Status: Enables or disables the System Log function.

Log Type: Select the Log Type mode you would like to use.

Remote Log: Enables or disables the Remote Log feature. If enabled, enter the IP address of the Log you would like to remote to.

Log Server IP Address: Enter the IP address of the log server.

Apply: Click Apply to save the changes.

Reset

In some circumstances, you may be required to force the device to reboot. Click a Reboot the Deviceto reboot the device.

EnGenius® EWS320AP Dual Radio AP , 3T3R , 450Mbps + 450Mbps Changes : 0 Reset Logout Overview Reboot the device Device Status Caution: Pressing this button will cause the device to reboot. Connections Reboot the Device Network Basic Wireless Management Restore the device to default settings Advanced Caution: All settings will be cleared and reset to either factory default or user default. Restore to Factory Default Restore to User Default

Logout

Click Logout, it will pop up a warning window. Click OK to logout.

EnGenius® EWS320AP Dual Radio AP , 3T3R , 450Mbps + 450Mbps Changes : 0 Reset Logout

Message from webpage Are you sure you want to logout? OK Cancel

Appendix

ENGENIUS EWS300AP - Appendix - 1

natural_image White EnGenius wireless router device with no visible text or symbols on the body

Appendix A - FCC Interference Statement

Federal Communication Commission Interference Statement

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:

• Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.

ENGENIUS EWS300AP - Appendix A - FCC Interference Statement - 1

FCC Caution:

Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Operations in the 5.15-5.25 GHz band are restricted to indoor usage only.

IMPORTANT NOTE:

Radiation Exposure Statement

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 23 cm between the radiator & your body.

Appendix B - IC Interference Statement

Industry Canada Statement

This device complies with RSS-210 of the Industry Canada Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

(i) the device for operation in the band 5150-5250 MHz is only for indoor use to reduce the potential for harmful interference to co-channel mobile satellite systems;
(ii) high-power radars are allocated as primary users (i.e. priority users) of the bands 5250-5350 MHz and 5650-5850 MHz and that these radars could cause interference and/or damage to LE-LAN devices.

ENGENIUS EWS300AP - Appendix B - IC Interference Statement - 1

Avertissement:

Radiation Exposure Statement

This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body.

Europe – EU Declaration of Conformity

EN60950-1

Safety of Information Technology Equipment

EN50385

Generic standard to demonstrate the compliance of electronic and electrical apparatus with the basic restrictions related to human exposure to electromagnetic fields (0 Hz - 300 GHz)

• EN 300 328

Electromagnetic compatibility and Radio spectrum Matters (ERM); Wideband Transmission systems; Data transmission equipment operating in the 2,4 GHz ISM band and using spread spectrum modulation techniques; Harmonized EN covering essential requirements under article 3.2 of the R&TTE Directive

• EN 301 893

Broadband Radio Access Networks (BRAN); 5 GHz high performance RLAN; Harmonized EN covering essential requirements of article 3.2 of the R&TTE Directive

• EN 301 489-1

Electromagnetic compatibility and Radio Spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements

• EN 301 489-17

Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 17: Specific conditions for 2,4 GHz wideband transmission systems and 5 GHz high performance RLAN equipment

This device is a 5GHz wideband transmission system (transceiver), intended for use in all EU member states and EFTA countries, except in France and Italy where restrictive use applies.

In Italy the end-user should apply for a license at the national spectrum authorities in order to obtain authorization to use the device for setting up

outdoor radio links and/or for supplying public access to telecommunications and/or network services.

This device may not be used for setting up outdoor radio links in France and in some areas the RF output power may be limited to 10mW EIRP in the frequency range of 2454 - 2483.5 MHz. For detailed information the end-user should contact the national spectrum authority in France.

CE0560!

csČesky [Czech][Jméno výrobce] tímto prohlašuje, že tento [typ zařízení] je ve shodě se základními požadavky a dalšími příslušnými ustanoveními směrnice 1999/5/ES.
daDansk [Danish]Undertegnede [fabrikantens navn] erklærer herved, at følgende udstyr [udstyrets typebetegnelse] overholder de væsentlige krav og øvrige relevante krav i direktiv 1999/5/EF.
deDeutsch [German]Hiermit erklärt [Name des Herstellers], dass sich das Gerät [Gerätetyp] in Übereinstimmung mit den grundlegenden Anforderungen und den übrigen einschlägigen Bestimmungen der Richtlinie 1999/5/EG befindet.
etEesti [Estonian]Käesolevaga kinnitab [tootja nimi = name of manufacturer] seadme [seadme tüüp = type of equipment] vastavust direktiivi 1999/5/EÜ põhinõuetele ja nimetatud direktiivist tulenevatele teistele asjakohastele sätetele.
enEnglishHereby, [name of manufacturer], declares that this [type of equipment] is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.
esEspañol [Spanish]Por medio de la presente [nombre del fabricante] declara que el [clase de equipo] cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999/5/CE.
elEλληνική [Greek]ME THN ΠΑΡΟΥΣΑ [name of manufacturer] ΔΗΛΩΝΕΙ OTI [type of equipment] ΣΥΜΜΟΡΦΩΝΕΤΑΙ ΠΡΟΣ ΤΙΣ ΟΥΣΙΩΔΕΙΣ ΑΠΑΙΤΗΣΕΙΣ ΚΑΙ ΤΙΣ ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ ΔΙΑΤΑΞΕΙΣ ΤΗΣ ΟΔΗΓΙΑΣ 1999/5/EK.
frFrançais [French]Par la présente [nom du fabricant] déclare que l'appareil [type d'appareil] est conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999/5/CE.
itItaliano [Italian]Con la presente [nome del costruttore] dichiara che questo [tipo di apparecchio] è conforme airequisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999/5/CE.
Latviski [Latvian]Ar šo [name of manufacturer / izgatavotāja nosaukums] deklarē, ka [type of equipment / iekārtas tips] atbilst Direktīvas 1999/5/EK būtiskajām prasībām un citiem ar to saistītajiem noteikumiem.
Lietuvių [Lithuanian]Šiuo [manufacturer name] deklarujoja, kad šis [equipment type] atitinka esminius reikalavimus ir kitas 1999/5/EB Direktyvos nuostatas.
Nederlands [Dutch]Hierbij verklaart [naam van de fabrikant] dat het toestel [type van toestel] in overeenstemming is met de essentiële eisen en de andere relevante bepalingen van richtlijn 1999/5/EG.
Malti [Maltese]Hawnhekk, [isem tal-manifattur], jiddikjara li dan [il-mudel tal-prodott] jikkonforma mal-ħtiġijiet essenzjali u ma provvedimenti oħrajn relevanti li hemm fid-Dirrettiva 1999/5/EC.
Magyar [Hungarian]Alulírott, [gyártó neve] nyilatkozom, hogy a [... típus] megfelel a vonatkozó alapvetō követelményeknek és az 1999/5/EC irányelv egyéb előírásainak.
Polski [Polish]Niniejszym [nazwa producenta] oświadcza, że [nazwa wyrobu] jest zgodny z zasadniczymi wymogami oraz pozostałymi stosownymi postanowieniami Dyrektywy 1999/5/EC.
Português [Portuguese][Nome do fabricante] declara que este [tipo de equipamento] está conforme com os requisitos essenciais e outras disposições da Directiva 1999/5/CE.
Slovensko [Slovenian][Ime proizvajalca] izjavlja, da je ta [tip opreme] v skladu z bistvenimi zahtevami in ostalimi relevantnimi določili direktive 1999/5/ES.
Slovensky [Slovak][Meno výrobcu] týmto vyhlasuje, že [typ zariadenia] spĺňa základné požiadavky a všetky príslušné ustanovenia Smernice 1999/5/ES.
Suomi [Finnish][Valmistaja = manufacturer] vakuuttaa täten että [type of equipment = laitteen tyyppimerkintä] tyyppinen laite on direktiivin 1999/5/EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen.
Svenska [Swedish]Härmed intygar [företag] att denna [utrustningstyp] står l överensstämmelse med de väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av direktiv 1999/5/EG.
Table of contents Click a title to access it
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : ENGENIUS

Model : EWS300AP

Category : Access Point