AcuRite 00634A3 - Weather Station

00634A3 - Weather Station AcuRite - Free user manual and instructions

Find the device manual for free 00634A3 AcuRite in PDF.

📄 16 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice AcuRite 00634A3 - page 5
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Wireless Weather Station
Brand AcuRite
Model 00634A3
Outdoor Sensor 3-in-1 sensor: temperature, humidity, wind speed
Display Unit Features Atomic clock, barometric pressure, moon phase, self-calibrating 12-24 hour forecast, history chart, high/low records, indoor temp/humidity
Power Supply Display: 3 x AA alkaline; Sensor: 4 x AA alkaline or lithium (lithium recommended below -4°F/-20°C)
Wireless Range 330 ft (100 m) in open air
Operating Frequency 433 MHz
Outdoor Temperature Range -40°F to 158°F (-40°C to 70°C)
Indoor Temperature Range 32°F to 122°F (0°C to 50°C)
Outdoor Humidity Range 1% to 99%
Indoor Humidity Range 16% to 98%
Wind Speed Range 0 to 99 mph (0 to 159 kph)
Data Update Interval Outdoor: every 18 seconds; Indoor: every 60 seconds
Forecast Technology Self-Calibrating Forecasting with Learning Mode (14 days initial, 33 days full)
Mounting Options Tabletop stand or wall mount for display; pole or post mount for sensor (min 5 ft height recommended)
Display Dimensions (approx) 6.5 x 3.5 x 1.2 inches
Warranty 1 year limited
Cleaning Instructions Clean with soft damp cloth; avoid caustic cleaners; lubricate anemometer with graphite if needed
Regulatory Compliance FCC Part 15 Class B

Frequently Asked Questions - 00634A3 AcuRite

How do I set up the AcuRite 00634A3 weather station?
Set the A-B-C switch inside the battery compartments of both the display and sensor to the same letter (A, B, or C). Install batteries: 3 AA in display, 4 AA in sensor (lithium for sensor in cold). Place units within 330 ft. The sensor will sync within 20 minutes. Then set time, date, and units using the SET and SCALE buttons.
Why is my outdoor temperature flashing or showing dashes?
Flashing or dashes indicate wireless interference or loss of signal. Ensure both units have the same A-B-C switch setting. Reduce distance to under 330 ft. Move units away from electronics (TV, microwave, computer). Re-sync by bringing units indoors, removing batteries, and reinstalling after setting same channel.
How does the self-calibrating forecast work?
The station enters Learning Mode for 14 days, analyzing pressure changes to determine your altitude. After 14 days, the Learning Mode icon disappears, and the forecast becomes personalized. For full accuracy, allow 33 days of continuous operation without battery removal.
How do I reset the high/low records?
Press MIN/MAX to view MIN records, then simultaneously press and hold the '+' and SCALE buttons for 3 seconds. Dashes confirm reset. Repeat for MAX records.
Why is my wind speed reading inaccurate?
Ensure the sensor is mounted at least 5 feet high in an open area free of obstructions (trees, buildings). The wind cups must spin freely; lubricate with graphite powder if hesitant. Compare data from similar mounting heights for validation.
What batteries should I use for the 3-in-1 sensor?
AcuRite recommends high-quality alkaline or lithium batteries. In temperatures below -4°F (-20°C), use lithium batteries as alkaline may fail. Do not use heavy duty or rechargeable batteries.
How do I clean the outdoor sensor?
Clean the sensor housing with a soft, damp cloth. Do not use caustic cleaners. To prevent insects from nesting, spray with household insect repellent following label instructions. Lubricate the anemometer with graphite powder if movement is stiff.
What does the history chart show?
The multi-variable history chart displays the past 12 hours of barometric pressure, temperature, or wind speed data. Press the HISTORY MODE button to toggle between these parameters.
How do I set the atomic clock?
After powering on, the display will synchronize with the NIST WWVB signal. It may take a few hours. To manually set the time, press and hold SET for 5 seconds, then adjust the flashing preference using the '+' button. The order is: time zone, DST, hour, minute, year, month, date.
What should I do if the display screen stops working?
Check battery installation and replace if needed. Press the RESET button on the back of the display unit. After reset, you will need to set the time, date, and units again. If the issue persists, contact AcuRite support at (877) 221-1252.

User questions about 00634A3 AcuRite

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Weather Station in PDF format for free! Find your manual 00634A3 - AcuRite and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. 00634A3 by AcuRite.

USER MANUAL 00634A3 AcuRite

Unpacking Instructions......2

Package Contents......2

Product Registration......2

Features & Benefits: 3-in-1 ......3

Features: Display Unit......4

Setup 6

3-in-1 Sensor Setup......6

Display Unit Setup....7

Set Time, Date & Units 8

Sensor & Display Placement......9

3-in-1 Sensor Installation ..... 10

Using the Weather Center......11

Troubleshooting......12

Care & Maintenance ....14

Specifications....14

FCC Information....14

Customer Support 15

Warranty....15

Questions? Contact Customer Support at

(877) 221-1252 or visit www.AcuRite.com.

SAVE THIS MANUAL FOR FUTURE REFERENCE.

ACURITE®

Congratulations on your new AcuRite product. To ensure the best possible product performance, please read this manual in its entirety and retain it for future reference.

Unpacking Instructions

Remove the protective film that is applied to the LCD screen prior to using this product. Locate the tab and peel off to remove.

Package Contents

  1. Display unit with tabletop stand
  2. 3-in-1 sensor
  3. Sensor mounting bracket
  4. Mounting hardware
  5. Instruction Manual

IMPORTANT PRODUCT MUST BE REGISTERED TO RECEIVE WARRANTY SERVICE PRODUCT REGISTRATION Register online to receive 1 year warrantyprotection www.AcuRite.com SUPPORT Support Forum Archived Products ►Register a Product

Features & Benefits

THREE-IN-ONE WIRELESS SENSOR 1 2 3 4 5 6

3-in-1 SENSOR

  1. Temperature & Humidity Sensors (internal)
  2. Release Lever for Battery Access
  3. Mounting Point
  4. Wind Speed Anemometer

  5. Mounting Hardware

Includes anchors and screws.

  1. Mounting Bracket

  2. A-B-C Switch (not shown)

ID code that must match display's A-B-C switch to ensure units synchronize.

Features & Benefits

Display Unit

benefits 1 2 3 4 5 2/16 12:35° TIMEZONE CST FUTURE FORECAST BAROMETRIC PRESSURE 29.87 °F MOONPHASE WIND SPEED TEMPERATURE 20 mph kph 35° MAX MIN 36° PEAK AVERAGE NEMOR LOW WIND CHILL 12°F 70°F 40% INDOOR MAX MIN -12 -4 -3 -2 1 0 90 - 80 - 70 - 60 - 50 - 40 - 30 - 20 - 10 - °F HISTORY - HOURS ADD BAROMETER >TEMPERATURE WIND SPEED SET + HISTORY MODE SCALE MIN/MAX CLEAR 18 17192021 16

30 31 32 33 34

DISPLAY UNIT

  1. Date
  2. Low Battery Indicator
  3. Atomic Clock

Maintains time with split-second accuracy and automatically updates for daylight saving time.

  1. Atomic Clock Signal Strength
  2. Selected Time Zone
  3. Barometric Pressure

Arrow icon indicates the direction the pressure is trending.

  1. History Chart Icon
    Indicates data is currently displayed on the History Chart (22).
  2. Moon Phase
  3. History Chart Icon

Indicates data is currently displayed on the History Chart (22).

  1. Current Outdoor Temperature

Arrow icon indicates direction temperature is trending.

  1. Sensor Signal Strength
  2. Low Sensor Battery Indicator
  3. Current Indoor Humidity
  4. High/Low Records Indicator

Indicates whether minimum or maximum records are being shown.

  1. Current Indoor Temperature
  2. Removable Tabletop Stand
  3. MIN/MAX Button

Press to view high or low records for temperature and humidity.

  1. SCALE Button

Changes data units to either U.S. units or imperial units.

  1. HISTORY MODE Button

Press to toggle between pressure, temperature and wind speed data on the History Chart (22).

    • Button

For setup preferences.

  1. SET Button

For setup preferences.

  1. Multi-Variable History Chart

Displays the past 12 hours of data for pressure, temperature or wind speed.

  1. Seasonal

Displays heat index, dew point or wind chill, depending on the current outdoor temperature.

  1. Average Wind Speed

Based on all wind speed readings from the past 2 minutes.

  1. Peak Wind Speed

Highest speed from past 60 minutes.

  1. Current Wind Speed

  2. History Chart Icon

Indicates data is currently displayed on the History Chart (22).

  1. Learning Mode Icon

Disappears after weather forecast self-calibration is complete.

  1. 12 to 24 Hour Weather Forecast

Self-Calibrating Forecasting pulls data from the outdoor sensor to generate your personal forecast.

BACK OF DISPLAY UNIT

  1. Reset Button

Full reset to factory defaults.

  1. Integrated Hang Hole

For easy wall mounting

  1. A-B-C Switch

ID code that must match sensor's A-B-C switch to ensure units synchronize.

  1. Battery Compartment Cover

  2. Battery Compartment

3-IN-1 Sensor Setup

1 Set the A-B-C Switch

The A-B-C switch is located inside the battery compartment. It can be set to A, B or C. However, you must select the same letter choices for both the sensor and the display unit in order for the units to synchronize.

② Install or Replace Batteries

AcuRite recommends high quality alkaline or lithium batteries for the best product performance. Heavy duty or rechargeable batteries are not recommended.

The 3-in-1 sensor requires lithium batteries in low temperature conditions. Cold temperatures can cause alkaline batteries to function improperly. Use lithium batteries in the 3-in-1 sensor for temperatures below -4°F / -20°C.

  1. Press the release lever and pull off the lower housing of the sensor.
  2. Remove the battery compartment cover. Take note of the A-B-C switch setting inside the battery compartment for step 2.
  3. Insert 4 x AA batteries into the battery compartment, as shown. Follow the polarity (+/-) diagram in the battery compartment.
  4. Replace the battery cover and lower housing of the sensor.

condensate, cold temperatures can cause alkaline batteries to function improperly. Use lithium batteries in the 3-in-1 sensor for temperatures below -4°F / -20°C. ① A-B-C Switch set to match displayunit ② Install Batteries 4 AA batteries LITHIUM BATTERIES -40°F (-40°C) (70°C) 158°F ALKALINE BATTERIES -4°F (-20°C) (70°C) 158°F

Display Unit Setup

1 Set the A-B-C Switch

Locate the A-B-C switch inside the battery compartment. Set the A-B-C switch to A, B or C. You must select the same letter choices for both the display unit and the sensor in order for the units to synchronize.

② Install or Replace Batteries

  1. Remove the battery compartment cover.
  2. Insert 3 x AA alkaline batteries into the battery compartment, as shown. Follow the polarity (+/-) diagram in the battery compartment.
  3. Replace the battery cover.

① A-B-C Switch set to match sen A B C ② Install Batteries 3 AA Batteries

AcuRite 00634A3 - ② Install or Replace Batteries - 2

PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE WAY AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS.

BATTERY SAFETY: Clean the battery contacts and also those of the device prior to battery installation. Remove batteries from equipment which is not to be

used for an extended period of time. Follow the polarity (+/-) diagram in the battery compartment. Promptly remove dead batteries from the device. Dispose of used batteries properly. Only batteries of the same or equivalent type as recommended are to be used. DO NOT incinerate used batteries. DO NOT dispose of batteries in fire, as batteries may explode or leak. DO NOT mix old and new batteries or types of batteries (alkaline/standard). DO NOT use rechargeable batteries. DO NOT recharge non-rechargeable batteries. DO NOT short-circuit the supply terminals.

Atomic Clock

AcuRite atomic clocks use a radio-controlled signal to synchronize to the correct time broadcast by the National Institute of Standards and Technology (NIST) Radio Station WWVB, located near Fort Collins, Colorado. WWVB broadcasts the current time and date with split-second accuracy.

This AcuRite atomic clock and calendar will maintain the correct time and date, and automatically update for daylight saving time to provide the most accurate timekeeping standard possible.

Please note: The atomic signal generally takes a few hours to synchronize, so it is important to manually set the time and date after powering on the display.

Set the Time & Date

Press AND HOLD the "SET" button for 5 seconds to enter SET MODE. Once in set mode, the preference you are currently setting will blink on the display.

To adjust the currently selected (flashing) item, press the “+” button (press and HOLD to fast adjust).

To save your adjustments, press and release the "SET" button again to adjust the next preference. The preference set order is as follows:

TIME ZONE (PST MST CST EST)

DST (Daylight Saving Time ON OR OFF)

CLOCK HOUR

CLOCK MINUTE

CALENDAR YEAR

CALENDAR MONTH

CALENDAR DATE

You will automatically exit SET MODE if no buttons are pressed for 30 seconds. Enter basic setup mode at any time by pressing and holding the "SET" button.

Select Measurement Units

To select between U.S. standard units or imperial units, press the "SCALE" button.

Please note: The "WIND SPEED" history chart only displays data in "mph".

Measurement U.S. Standard Units Imperial Units
TemperatureDegrees Fahrenheit (°F)Degrees Celsius (°C)
Barometric PressureinHg (inches of mercury)hPa (Hectopascal)
Wind SpeedMiles per hour (mph)Kilometers per hour (kph)

Placement for Maximum Accuracy

AcuRite sensors are sensitive to surrounding environmental conditions. Proper placement of both the display unit and the sensor are critical to the accuracy and performance of this product.

AcuRite 00634A3 - Placement for Maximum Accuracy - 1

Display Unit Placement

Place the display unit in a dry area free of dirt and dust. To ensure accurate temperature measurement, place out of direct sunlight and away from heat sources or vents. Display unit stands upright for tabletop use or is wall-mountable.

AcuRite 00634A3 - Display Unit Placement - 1

3-in-1 Sensor Placement

The 3-in-1 sensor is designed to remain outdoors all year long. Choose an open location with no obstructions above or around the sensor for the most accurate measurements.

Important Placement Guidelines

Display unit and sensor must be within 330 feet (100 m) of each other.

MAXIMIZE WIRELESS RANGE

Place units away from large metallic items, thick walls, metal surfaces, or other objects that may limit wireless communication.

PREVENT WIRELESS INTERFERENCE

Place both units at least 3 feet (.9 m) away from electronic devices (TV, computer, microwave, radio, etc.).

LOCATE AWAY FROM HEAT SOURCES

Position sensor away from heaters, air conditioners, chimneys, exhaust vents, asphalt and concrete (surfaces that radiate heat).

LOCATE AWAY FROM HUMIDITY SOURCES

Avoid installing the sensor near pools, spas, or other bodies of water. Water sources may impact humidity accuracy.

LOCATE AWAY FROM SPRINKLER HEADS

DO NOT install the sensor where it will be sprayed by a sprinkler system. This may force water inside the sensor.

LOCATE AWAY FROM WIND OBSTRUCTIONS

DO NOT mount the sensor with obstructions around it. Consider a location that is a wide open area, with few structures around to ensure accurate wind speed measurement.

Visit us online to view installation photos and video, or learn more about AcuRite technology:

www.AcuRite.com/3in1

QR code image containing encoded data, no visible human-readable text

View Video

3-in-1 Sensor Installation Guidelines

INSTALLATION HEIGHT Mount the sensor at least 5 feet (1.5 meters) off the ground (higher is better for wind measurement) in an open area. Secure to fence post, 2'×4' wood, 3/4" pole, etc. (not included)

LEVEL INSTALLATION Use a bubble level (not included) to ensure level installation for accurate wind measurement.

Top or Side Mount

  1. Insert the mounting base into the hole on the bottom of the sensor.
  2. Use one of the screws included in the hardware bag to fasten the lower sensor housing to the mounting base.
  3. Make sure the sensor is level using a bubble level.
  4. Fasten mounting base to a post or railing using 2 screws.

Top Mount Side MOUNTING BRACKET SCREWS

Mount
bunt MOUNTING BRACKET SCREWS ←←→

Pole Mount

  1. Insert pole (we recommend 3/4" schedule 40 PVC / 25.8 mm O.D., not included) or similar item all the way into the hole on the bottom of the sensor. Note: Mounting base is not used.
  2. Use one of the screws included in the hardware bag to fasten the lower sensor housing securely to the pole.
  3. Make sure the sensor is level using a bubble level.

The 3-in-1 sensor is now ready to use.

Pole Mount Do not install during electrical storms. Do not place pole or sensor near electrical lines or electrical equipment.

Basic Setup is Complete

The 3-in-1 sensor will now synchronize with the display unit. It may take a few minutes for synchronization to complete. If both or one of the units appear to be functioning improperly, please refer to the troubleshooting section.

Using The Weather Center

Learning Mode

Self-Calibrating Forecasting use a unique algorithm to analyze changes in pressure over a time period (called Learning Mode) to determine your altitude. After 14 days, the Learning Mode icon disappears from the display screen. At this point, the self-calibrated pressure is tuned in to your location and the unit is ready for superior weather prediction.

Weather Forecast

AcuRite's patented Self-Calibrating Forecasting provides your personal forecast of weather conditions for the next 12 to 24 hours by collecting data from the sensor in your backyard. It generates a forecast with pinpoint accuracy - personalized for your exact location.

HEAVY STORM STORMY MOSTLY CLOUDY PARTLY CLOUDY MOSTLY SUNNY

View the complete list of icons at www.AcuRite.com/acurite-icons

Moon Phase

Track the phases of the moon, conveyed through simple lunar phase icons.

AcuRite 00634A3 - Moon Phase - 1
NEWWAXING

CRESCENT
AcuRite 00634A3 - Moon Phase - 2

AcuRite 00634A3 - Moon Phase - 3
1ST QUARTER

AcuRite 00634A3 - Moon Phase - 4
WAXING GIBBOUS

AcuRite 00634A3 - Moon Phase - 5
FULL

AcuRite 00634A3 - Moon Phase - 6
WANING GIBBOUS

AcuRite 00634A3 - Moon Phase - 7
3RD QUARTER

AcuRite 00634A3 - Moon Phase - 8
WANING CRESCENT

Multi-Variable History Chart

The multi-variable history chart lets you monitor the change in conditions over the last 12 hour time period (-12, -6, -3, -2, -1, 0). Toggle between barometric pressure, temperature and wind speed readings.

Wind Speed

The Wind Speed area of the display features WIND SPEED PEAK, AVERAGE and CURRENT WIND SPEED. The multi-variable history chart lets you monitor the change in AVERAGE hourly wind speed.

Barometric Pressure

Subtle variations in barometric pressure greatly impact the weather. This weather center displays the current pressure with an arrow icon to indicate the direction the pressure is trending (FALLING, STEADY, or RISING). The multi-variable history chart lets you monitor the change in pressure over time.

High & Low Records

The "MIN/MAX" button displays minimum and maximum recordings for outdoor and indoor temperature and humidity. To view the MINIMUM temperature and humidity readings, press and release the "MIN/MAX" button until the "MIN" icon appears on the display next to the low records. To view the MAXIMUM temperature and humidity readings, press and release the "MIN/MAX" button until the "MAX" icon appears on the display next to the high records.

To reset the MINIMUM records, first view the MIN records by pressing the "MIN/MAX" button until the "MIN" icon appears on the display. While viewing the MIN records, press and hold the "+" and "SCALE" buttons simultaneously for 3 seconds. Dashes will display to confirm all MIN values have been cleared.

To reset the MAXIMUM records, first view the MAX records by pressing the "MIN/MAX" button until the "MAX" icon appears on the display. While viewing the MAX records, press and hold the "+" and "SCALE" buttons simultaneously for 3 seconds. Dashes will display to confirm all MAX values have been cleared.

Troubleshooting

Problem PossibleSolution
No outdoor sensor receptionno barsRelocate the display unit and/or the 3-in-1 sensor.The units must be within 330 ft (100 m) of each other.Make sure both units are placed at least 3 feet (.9 m)away from electronics that may interfere with the wireless communication (such as TVs, microwaves, computers, etc).Use standard alkaline batteries (or lithium batteries in sensor when temperature is below -4°F/-20°C). Do not use heavy duty or rechargeable batteries. NOTE: It may take up to 20 minutes for display unit and sensor to synchronize after batteries are replaced.Synchronize the units:Bring both the sensor and display unit indoors and remove at least one battery from each.Make sure the A-B-C switch on both units match.Reinstall the battery in the outdoor sensor.Reinstall battery into the display unit.Let the units sit within a couple feet of each other for about 20 minutes to gain a strong connection.
Outdoor temperature is flashing or showing dashesFlashing of the outdoor temperature may be an indication of wireless interference:Make sure the A-B-C switch in the battery compartments of both the display unit and sensor are switched to the same letter. You may choose A, B or C; but both units must match to sync up. Sometimes changing to a different channel helps.

Troubleshooting

Problem PossibleSolution
Inaccurate forecastWeather Forecast icon predicts conditions for the next 12 to 24 hours, not current conditions.Has Learning Mode icon disappeared from the display unit? Learning Mode must complete before forecast and pressure will be accurate.Allow unit to run continuously for 33 days. Battery removal or resetting the display unit will restart Learning Mode. After 14 days, forecast should be fairly accurate, however Learning Mode calibrates for a total of 33 days.
Inaccurate temperature or humidityMake sure both the display unit and 3-in-1 sensor are placed away from any heat sources or vents (see page 9).Make sure both units are positioned away from moisture sources (see page 9).Make sure 3-in-1 sensor is mounted at least 5 ft off of the ground.
Inaccurate wind readingsWhat is wind reading being compared to? Pro weather stations are typically mounted at 30 ft high or more. Make sure to compare data using a sensor positioned at the same mounting height.Check location of the sensor. Ensure it's mounted a minimum of 5 ft in the air with no obstructions around it (within several feet).Ensure wind cups are spinning freely. If they hesitate or stop try lubricating with graphite powder or spray lubricant.
Display screen not workingCheck that the batteries are installed correctly. Batteries may need to be replaced.Reset the display by pressing the reset button, located on the back of the display unit. Date and time will need to be entered after a reset.

If your AcuRite product does not operate properly after trying the troubleshooting steps, visit www.AcuRite.com or call (877) 221-1252 for assistance.

Care & Maintenance

Display Unit Care

Clean with a soft, damp cloth. Do not use caustic cleaners or abrasives. Keep away from dust, dirt and moisture. Clean ventilation ports regularly with a gentle puff of air.

3-in-1 Sensor Care

Clean the Sensor

Clean with a soft, damp cloth. Do not use caustic cleaners or abrasives.

Insect Prevention

Insects may cause obstructions and interrupt data by nesting in or on the 3-in-1 sensor. To limit this problem, spray sensor with a household insect repellent. Consult the insect repellent instructions prior to use.

Snow & Freezing Weather

The 3-in-1 sensor will not be damaged by freezing conditions.

Clean the Wind Anemometer

Remove foreign matter from the outside of the sensor for free movement of the wind anemometer. If needed, use a small amount of spray lubricant, clear silicone or graphite powder on the anemometer for improved movement.

Specifications

TEMPERATURE RANGEOutdoor: -40°F to 158°F; -40°C to 70°C
Indoor: 32°F to 122°F; 0°C to 50°C
HUMIDITY RANGEOutdoor: 1% to 99%
Indoor: 16% to 98%
WIND SPEED0 to 99 mph; 0 to 159 kph
WIRELESS RANGE330 ft / 100 m depending on home construction materials
OPERATING FREQUENCY433 mhz
POWER7 x AA alkaline or lithium batteries (not included)
DATA REPORTINGWind Speed: 18 second updates
Outdoor temperature & humidity: 18 second updates
Indoor temperature & humidity: 60 second updates

FCC Information

This device complies with part 15 of FCC rules. Operation is subject to the following two conditions:

1- This device may NOT cause harmful interference, and

2- This device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, There is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

- Reorient or relocate the receiving antenna.

- Increase the separation between the equipment and the receiver.

- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

- Consult the dealer or an experienced radio/TV technician for help.

NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user authority to operate the equipment.

Customer Support

AcuRite customer support is committed to providing you with best-in-class service. For assistance, please have the model number of this product available and contact us in any of the following ways:

AcuRite 00634A3 - Customer Support - 1

221-1252 info@chaney-inst.com

24/7 support at www.AcuRite.com

▶ Installation Videos
▶ Instruction Manuals
▶ Replacement Parts

▶ Register your Product
▶ Support User Forum
▶ Submit Feedback & Ideas

IMPORTANT

PRODUCT MUST BE REGISTERED TO RECEIVE WARRANTY SERVICE

PRODUCT REGISTRATION

Register online to receive 1 year warrantyprotection

www.AcuRite.com

SUPPORT

Support Forum

Archived Products

▶Register a Product

Limited One Year Warranty

At AcuRite, we proudly uphold our commitment to quality technology. Chaney Instrument Co. warrants that all products it manufactures to be of good material and workmanship, and to be free of defects when properly installed and operated for a period of one year from the date of purchase.

We recommend that you visit us at www.AcuRite.com for the fastest way to register your product. However, product registration does not eliminate the need to retain your original proof of purchase in order to obtain warranty benefits.

Chaney Instrument Co. warrants that all products it manufactures to be of good material and workmanship, and to be free of defects when properly installed and operated for a period of one year from the date of purchase. Remedy for breach of this warranty is limited to repair or replacement of the defective item(s). Any product which, under normal use and service, is proven to breach the warranty contained herein within ONE YEAR from date of sale will, upon examination by Chaney, and at its sole option, be repaired or replaced by Chaney. Transportation costs and charges for returned goods shall be paid for by the purchaser. Chaney hereby disclaims all responsibility for such transportation costs and charges. This warranty will not be breached, and Chaney will give no credit for products

it manufactures which have received normal wear and tear, been damaged (including by acts of nature), tampered, abused, improperly installed, damaged in shipping, or repaired or altered by others than authorized representatives of Chaney.

The above-described warranty is expressly in lieu of all other warranties, express or implied, and all other warranties are hereby expressly disclaimed, including without limitation the implied warranty of merchantability and the implied warranty of fitness for a particular purpose. Chaney expressly disclaims all liability for special, consequential or incidental damages, whether arising in tort or by contract from any breach of this warranty. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Chaney further disclaims all liability from personal injury relating to its products to the extent permitted by law. By acceptance of any of Chaney's products, the purchaser assumes all liability for the consequences arising from their use or misuse. No person, firm or corporation is authorized to assume for Chaney any other liability in connection with the sale of its products. Furthermore, no person, firm or corporation is authorized to modify or waive the terms of this paragraph, and the preceding paragraph, unless done in writing and signed by a duly authorized agent of Chaney. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

For in-warranty claims:

Chaney Instrument Co. | 965 Wells St. | Lake Geneva, WI 53147

ACU-RITE®

4.7 6.0 32° 4.3 1.0 1.0 1.0 1.0

Weather Stations

AcuRite 00634A3 - ACU-RITE® - 2
Temperature & Humidity

AcuRite 00634A3 - ACU-RITE® - 3
Weather Alert Radio

AcuRite 00634A3 - ACU-RITE® - 4
Kitchen Thermometers & Timers

AcuRite 00634A3 - ACU-RITE® - 5
Clocks

It's more than accurate, it's ACU-RITE.

AcuRite offers an extensive assortment of precision instruments, designed to provide you with information you can depend on to Plan your day with confidence™.

www.AcuRite.com

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : AcuRite

Model : 00634A3

Category : Weather Station