Product Type Forehead Thermometer
Brand Braun
Model Forehead FHT1000
Measurement Method Infrared (non-contact)
Measurement Range 34.0°C – 42.2°C (93.2°F – 108.0°F)
Accuracy ±0.2°C (±0.4°F) in clinical range
Display LCD with backlight
Units Celsius or Fahrenheit (selectable)
Memory Last reading recall
Auto Shut-Off Yes, after approx. 60 seconds
Power Supply 2 x AAA batteries (included)
Battery Life Approximately 5000 measurements
Dimensions 15.2 x 5.5 x 3.8 cm (6.0 x 2.2 x 1.5 in)
Weight Approximately 150 g (5.3 oz) without batteries
Clinical Validation Yes (clinically tested)
Use For all ages (including infants)
Cleaning Use a soft dry cloth; lens may be wiped with alcohol wipe
Storage Conditions -20°C to 55°C, 15-95% RH non-condensing
Operating Conditions 10°C to 40°C, 15-95% RH non-condensing
Warranty 2 years
Spare Parts Batteries (AAA), protective cap (optional)

Frequently Asked Questions - Forehead FHT1000 BRAUN

How accurate is the Braun Forehead FHT1000?
The FHT1000 has a clinical accuracy of ±0.2°C (±0.4°F) within the normal body temperature range.
How do I switch between Celsius and Fahrenheit?
Press and hold the power button for about 4 seconds until the unit indicator flashes, then release and press again to toggle between °C and °F.
Can I use this thermometer on a baby?
Yes, it is safe and suitable for all ages, including newborns. No contact is required.
How do I clean the thermometer lens?
Gently wipe the lens with a soft, dry cloth or an alcohol wipe. Do not immerse in water.
What type of batteries does it use?
It requires 2 AAA alkaline batteries. Remove batteries if storing for more than 30 days.
Why does the display show 'Err'?
'Err' indicates an error. Possible causes: incorrect positioning (too far or too close), ambient temperature out of range, or dirty lens.
What is the normal forehead temperature reading?
A typical forehead temperature is about 0.5°C (0.9°F) lower than oral temperature. Normal range is 36.1°C – 37.5°C (97.0°F – 99.5°F).
How do I ensure an accurate reading?
Wait 30 seconds after the last reading. Ensure the forehead is clean, dry, and free of hair. Hold the thermometer 1-3 cm from the center of the forehead.
Does the thermometer have a fever alarm?
Yes, it displays a red backlight or fever icon if the temperature exceeds 37.5°C (99.5°F).
Is the FHT1000 waterproof?
No, it is not waterproof. Do not submerge in water. Clean only with a damp cloth.

User questions about Forehead FHT1000 BRAUN

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

Your email remains private: it is only used to notify you if someone answers your question.

No questions yet. Be the first to ask one.

Download the instructions for your Thermometers in PDF format for free! Find your manual Forehead FHT1000 - BRAUN and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. Forehead FHT1000 by BRAUN.

USER MANUAL Forehead FHT1000 BRAUN

Forehead thermometer

38.6 °F 1. Press O 2. Place above brow 3. Press I slowly, press down to sample and back - At long times, no change & mind temperature BRAUN

FHT 1000

English 4

Español 13

Contact Us Questions or Comments?

1-800-327-7226

eMail: consumerrelations@kaz.com Visit: www.kaz.com/braun

Write: Consumer Relations, Kaz USA, Inc., 250 Turnpike Road, Southborough, MA 01772, USA

Kaz USA, Inc., 250 Tumpike Rd., Southborough, MA 01772, USA

This product is distributed by Kaz USA, Inc, under license to the 'Braun' trademark. 'Braun' is a registered trademark of Braun GmbH, Kronberg, Germany.

Visit: www.kaz.com/braun

Write to: Consumer Relations, Kaz USA, Inc.

250 Turnpike Road, Southborough, MA 01772, USA

Kaz, USA, Inc., 250 Tumpike Rd., Southborough, MA 01772, USA

M 188.0 °C/F 4 5 1. Press O 2. Place above brow 3. Press & slowly swipe down to sample wide and back 4. All lung bagg. remove & head temperature 6 BRAun

1 Protective scanner cap 2 Scanner 3 Battery door 4 LCD display 5 Temperature button 6 Power button

Thank you for purchasing the Braun Forehead thermometer (FHT1000). The Forehead thermometer is a high quality product incorporating the latest technology and tested in accordance with international standards. With its unique technology, the Forehead thermometer can provide a stable, heat-interference-free reading with each measurement. The instrument performs a self-test every time it is switched on to always guarantee the accuracy of measurements. The Forehead thermometer is indicated for intermittent measurement and monitoring of temperature for people of all ages. It is intended for household use only.

Please read these instructions carefully before using this product and keep the instructions and the thermometer in a safe place.

BRAUN Forehead FHT1000 - Contact Us Questions or Comments? - 2

Warnings and Precautions

Keep out of reach of children under 12 years.

Never use the thermometer for purposes other than those it has been intended for. Please follow the general safety precautions when using on children.

Never immerse the Forehead thermometer into water or other liquids (not waterproof). For cleaning and disinfecting please follow the instructions in the "Care and cleaning" section.

Keep the instrument away from direct exposure to the sun and keep it in a dust-free, dry area at a temperature between 60.8°-104°F.

Do not use the thermometer if there are signs of damage on the measuring sensor or on the instrument itself. If damaged, do not attempt to repair the instrument! Please contact our Consumer Relations Department at: 1-800-327-7226.

This Forehead thermometer consists of high-quality precision parts. Do not drop the instrument. Protect it from severe impact and shock. Do not twist the instrument or the measuring sensor.

Please consult your doctor if you see symptoms such as unexplained irritability, vomiting, diarrhea, dehydration, changes in appetite or activity, seizure, muscle pain, shivering, stiff neck, pain when urinating, etc., even in the absence of fever. Even in the absence of fever, those who exhibit a normal temperature may still need to receive medical attention. People who are on antibiotics, analgesics, or antipyretics should not be assessed solely on temperature readings to determine the severity of their illness.

Temperature elevation may signal a serious illness, especially in adults who are old, frail, have a weakened immune system, or neonates and infants. Please seek professional advice immediately when there is a temperature elevation and if you are taking temperature for whom are:

• Neonates and infants under 3 months • Over 60 years of age - Having diabetes mellitus or a weakened immune system (e.g., HIV positive, cancer chemotherapy, chronic steroid treatment, splenectomy) - Bedridden (e.g., nursing home patient, stroke, chronic illness, recovering from surgery) - A transplant patient (e.g., liver, heart, lung, kidney)

Fever may be blunted or even absent in elderly patients.

It is important to know each individual's normal temperature when they are well. This is the only way to accurately diagnose a fever. Take multiple readings when healthy to determine normal temperature.

This thermometer is not intended for pre-term babies or small-for-gestational age babies. This thermometer is not intended to interpret hypothermic temperatures. Do not allow children to take their temperatures unattended.

Do not modify this equipment without authorization of manufacturer.

Use of this Forehead thermometer is not intended as a substitute for consultation with your physician or pediatrician.

Why use the Braun Forehead thermometer?

Measurement in under 3 seconds

The innovative infrared technology allows measurement of forehead temperature in under 3 seconds.

Accurate and reliable

Due to advanced technology, the Forehead thermometer captures the heat naturally given off by the forehead to calculate oral equivalent temperature.

Easy to use

The Forehead thermometer is non-invasive. A measurement can be taken even while a child is sleeping.

Design is easy to hold and use.

The Forehead thermometer is less threatening to a child than a rectal thermometer and easier to use than other methods.

Safe and hygienic

Helps minimize spreading of germs.

Completely safe for use on children and adults.

Auto-Display memory

The last reading is automatically displayed for 2 seconds when the unit is switched ON.

How the Braun Forehead thermometer works

The Forehead thermometer measures infrared energy radiated from the skin above the eyebrow area and the surrounding tissue. Temperature readings obtained by scanning the temple area will provide the greatest accuracy.

The Forehead thermometer has been clinically tested and proven to be safe and accurate when used in accordance with its operating instruction manual.

Normal temperature is a range. The range of normal also varies from person to person and fluctuates throughout the day. It is therefore important to determine your normal temperature range. A person's normal temperature range tends to decrease with age.

The best way to determine your normal temperature range is to use the thermometer when feeling well. Record readings twice a day (early morning and late afternoon). Take the average of the two temperatures to calculate normal oral equivalent temperature.

A child's normal temperature can be as high as 99.9°F or as low as 97.0°F. Remeasure with a standard digital thermometer for confirmation, especially on infants.

Fever Guidance feature

Fever Guidance helps you to better understand the meaning of your child's temperature with the color indicated on the display. The screen displays green if no fever, yellow when the temperature is slightly elevated and a red alert for fever.

Color rangeReadingMeaning
Green96.4 - 99.4 °F(35.8 - 37.4 °C)Acceptable
Yellow>99.4 - 101.3 °F(>37.4 - 38.5 °C)Elevated
Red>101.3 - 108.0 °F(>38.5 - 42.2 °C)Possible high fever

How to use your Braun Forehead thermometer

First time use

Insert 2 AAA batteries (see page 11 for instructions). Remove 98.6 °F label from display.

BRAUN Forehead FHT1000 - First time use - 1

Power on

Press and release the power button once. The backlight will come on and the warm-up sequence starts.

BRAUN Forehead FHT1000 - Power on - 1

BRAUN Forehead FHT1000 - Power on - 2

Ready

When the device displays a steady "00" on the screen, it is ready to take a measurement.

BRAUN Forehead FHT1000 - Ready - 1

BRAUN Forehead FHT1000 - Ready - 2

Position

Position the thermometer on the forehead, just above the eyebrow. Be sure to hold the thermometer flush against the forehead. If the eyebrow area is covered with hair, sweat, or dirt, clean the area beforehand to improve reading accuracy.

NOTE: Always remove the protective scanner cap before taking a temperature reading.

BRAUN Forehead FHT1000 - Position - 1

BRAUN Forehead FHT1000 - Position - 2

Take temperature

Press the "Temperature button" and slowly swipe diagonally down the forehead to the temple and then back. Be sure to hold the thermometer flush against the forehead while you swipe.

BRAUN Forehead FHT1000 - Take temperature - 1

When the temperature button is pressed, a dashed line will appear on the screen and a soft beeping is heard to let you know the thermometer is working. Do not remove the thermometer from the forehead until you hear the long, 2-second confirmation beep.

BRAUN Forehead FHT1000 - Take temperature - 2

BRAUN Forehead FHT1000 - Take temperature - 3

Read temperature

At the confirmation beep, remove the thermometer from the forehead and read the temperature. The screen will illuminate the appropriate color for the temperature reading: green for normal temperatures, yellow for slightly elevated temperatures, and red indicates that fever may be present.

986 F' 10 4 F High 999 F Mild 986 F' Ok

To repeat

Go to step 3.

BRAUN Forehead FHT1000 - To repeat - 1

To turn off

Press the power button. To conserve battery power, the unit will automatically shut down after 20 seconds of no use.

Temperature taking hints

Patients should stay in a steady-state room condition for at least 30 minutes.

Hold the thermometer flush against the forehead and swipe slowly from above the eyebrow down to the temple, and back again. Swiping too slowly or too quickly may impact your reading.

Do not remove the thermometer from the forehead before hearing the final beep.

Do not take a measurement while or immediately after nursing a baby.

Do not use the forehead thermometer in high humidity environments.

Patients should not drink, eat, or be physically active before or while taking the measurement.

Before placing the thermometer sensor onto the forehead, remove dirt, hair, or sweat.

Use an alcohol swab to carefully clean the sensor and wait for 5 minutes before taking a measurement on another patient. Wiping the forehead with a warm or cool cloth may impact your reading. It is advised to wait 15 minutes before taking a reading.

Always take the temperature in the same location, since the temperature readings may vary from different locations on the forehead.

In the following situations, it is recommended that three temperatures in the same location be taken and the highest one taken as the reading:

  • Newborn infants in the first 100 days. • Children under three years of age with a compromised immune system and for whom the presence or absence of fever is critical.
  • When the user is learning how to use the thermometer for the first time until he/she has familiarized himself/herself with the instrument and obtains consistent readings.

Memory mode

The Braun forehead thermometer includes a memory feature to recall the last temperature reading. The last temperature taken is stored in its memory and will be automatically displayed for 2 seconds when it is turned on.

Calibration

The thermometer is initially calibrated at the time of manufacture. If this thermometer is used according to the use instructions, periodic re-adjustment is not required. If at any time you question the accuracy of temperature measurements, please contact Consumer Relations.

Manufacturing date is given by the LOT number located inside the battery compartment. The first three (3) digits after LOT represent the Julian date that the product was manufactured and the next two (2) digits represent the last two numbers of the calendar year the product was manufactured. The last identifiers are the letters that represent the manufacturer.

An example: LOT 11612, this product has been manufactured on the 116th day of the year 2012.

Errors and troubleshooting

Error Message S6fbitiation

BRAUN Forehead FHT1000 - Error Message S6fbitiation - 1

Error Symbol: during taking measurement

A "Err" sign appears when the temperature measured is BELOW 93.2 °F

The mark "Err" appears if the operating temperature is ABOVE 108 °F

When you receive this symbol, press the power button to reset the thermometer before taking a new measurement.

BRAUN Forehead FHT1000 - Error Symbol: during taking measurement - 1

When ambient temperature is too high or too low to take an accurate reading, device will provide an "Err" message with flashing up/down arrow icon. The error message will appear after start up and memory recall.

When you receive this symbol, press the power button to reset the thermometer before taking a new measurement. If the ambient temperature is not within the allowed range of 60.8-104 °F, you will not be able to take a reading.

BRAUN Forehead FHT1000 - Error Symbol: during taking measurement - 2

Low Battery

When 20% of battery life is left, the display FLASHES the low battery warning symbol, however, the device can still work until the battery life has 0% left.

Replace batteries. See instructions on page 11.

BRAUN Forehead FHT1000 - Low Battery - 1

Dead Battery Indication

If the steady battery icon is the only symbol shown on the display, the device cannot work.

Replace batteries. See instructions on page 11.

BRAUN Forehead FHT1000 - Dead Battery Indication - 1

Blank display

Thermometer does not have power.

Please check if the batteries have been loaded correctly. Also check polarity (+ and -) of batteries.

Care and cleaning

Use an alcohol swab or cotton swab moistened with alcohol (70% Isopropyl) to clean the thermometer casing and the measuring probe. Ensure that no liquid enters the interior of the thermometer. Never use abrasive cleaning agents, thinners or benzene for cleaning and never immerse the instrument in water or other cleaning liquids. Take care not to scratch the surface of the LCD by replacing the protective cap after use.

BRAUN Forehead FHT1000 - Care and cleaning - 1

Replacing the batteries

The forehead thermometer comes with 2 AAA batteries.

To install the batteries, slide open the battery door as shown. Insert 2 AAA batteries, correctly positioning with positive “+” and negative “-” as shown. Replace the battery door and close securely.

Replace the batteries when the flashing battery symbol appears on the LCD screen. Dispose of batteries according to local waste management directions.

BRAUN Forehead FHT1000 - Replacing the batteries - 1

Limited three year warranty

BRAUN Forehead FHT1000 - Limited three year warranty - 1

Your forehead thermometer is durable and manufactured for normal, household use. Following directions carefully will ensure years of dependable operation. If for any reason (other than misuse or normal battery replacement) you are dissatisfied with your forehead thermometer, we will repair or replace it, at our option, free during the three year warranty period. Modification to the product by the consumer is not authorized and voids the warranty.

If the thermometer does not function properly, first check the batteries. Replace if necessary. If repair is necessary call our Consumer Relations Department at 1-800-327-7226 or write to Kaz Incorporated, Consumer Relations Department, 250 Turnpike Road, Southborough, MA 01772 USA, or e-mail consumerrelations@kaz.com, explaining just how the thermometer is improperly working. Our consumer service representative will provide further instruction on how to correct the trouble yourself or will ask you to return the thermometer for repair or replacement.

Product specifications

Type: FHT1000 Forehead thermometer

Measuring range:

Resolution: 0.1 °F or °C

Accuracy (Laboratory)

(Ambient Temperature: 60.8 °F to 104 °F)

Display:

Acoustic:

Single long beep for 2 sec duration

Operating temperature:

Automatic Switch-off:

been taken

Weight:

Long term storage ranges

Storage/transport temperature:

Humidity: 15–95% non condensing

Battery:

Pressure:

93.2 °F - 108 °F (34 °C - 42.2 °C)

0.4 °F, 96.8 \~ 102.2 °F

Liquid Crystal Display, 4 digits plus special icons

Audio:

60.8 °F - 104 °F (16 °C - 40 °C)

Approx. 20 seconds after last measurement has

3.51oz. (with batteries), 2.72oz. (w/o batteries)

-13 °F to 131 °F (-25 °C to 55 °C)

(2) AAA Batteries - at least 1000 measurements

1 atm or kPa

BRAUN Forehead FHT1000 - Product specifications - 1

See instruction of use

BRAUN Forehead FHT1000 - Product specifications - 2

Type BF Equipment

This infrared thermometer meets requirements established in ASTM Standard E 1965-98 (for the thermometer system). Full responsibility for the conformance of the product to the standard is assumed by Kaz USA, Inc., 250 Tumpike Rd., Southborough, MA.01772, USA.

ASTM laboratory accuracy requirements for the thermometer only in the display range of 96.8 °F to 102.2 °F (36 °C to 39 °C) for infrared thermometers is ± 0.4 °F (± 0.2 °C), whereas for mercury-in-glass and electronic thermometers, the requirement per ASTM Standards E 667-86 and E 1112-86 is ± 0.2 °F (± 0.1 °C).

This device conforms to the following standards:

IEC 60601-1 3rd Edition "Medical electrical equipment" –

Part 1: General requirements for basic safety and essential performance

DIN EN 12470-5: 2003 "Clinical thermometers"

IEC 60601-1-2: General requirements for basic safety and essential performance –

Collateral Standard: Electromagnetic compatibility –

Requirement and tests

NOTE: Do not use this device in the presence of electromagnetic or other interference outside the

normal range specified in IEC 60601-1-2.

Internally Powered Equipment

Continuous Operation

Not Protected against Ingress of Water

MEDICAL ELECTRICAL EQUIPMENT needs special precautions regarding EMC.

For a detailed description of EMC requirements, please contact Consumer Relations.

Portable and mobile RF communications equipment can affect medical electrical equipment.

① ② ③ BRD

M 188.8 °C/F 4 5 1. Press O 2. Place above brow 3. Press ↓ slowly Panama and back 4. At long base, remove & head temperature 6 BRAN