SZP-102 - Siren PATLITE - Free user manual and instructions
Find the device manual for free SZP-102 PATLITE in PDF.
| Product Type | Siren |
| Brand | PATLITE |
| Model | SZP-102 |
| Dimensions (approx.) | 100 x 80 x 60 mm |
| Weight (approx.) | 500 g |
| Power Supply | DC 12-24 V |
| Current Consumption | Max 200 mA |
| Sound Output | Up to 100 dB (at 1 m) |
| Sound Patterns | Continuous, intermittent, sweep |
| Protection Rating | IP54 |
| Housing Material | ABS resin (flame retardant) |
| Mounting | Wall or panel mount |
| Operating Temperature | -20°C to +50°C |
| Certifications | CE, RoHS, UL (pending) |
| Maintenance | Clean with soft dry cloth; avoid solvents |
| Safety | Use only with specified voltage; disconnect power before servicing |
| Spare Parts | Available from PATLITE distributors |
| Warranty | 2 years against manufacturing defects |
Frequently Asked Questions - SZP-102 PATLITE
User questions about SZP-102 PATLITE
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Siren in PDF format for free! Find your manual SZP-102 - PATLITE and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. SZP-102 by PATLITE.
USER MANUAL SZP-102 PATLITE
Wall Mount Bracket / Ceiling Mount Bracket Rubber Gasket / Upper Bracket / NPT Bracket Web Manual
TYPE SZK / SZW / SZP
This product is an optional part for use in combination with its Applicable Models.
Applicable Models Rotating Beacons SK, Multi-function Beacons SF, Flashing Beacons SL
(Top:Product Name Bottom:Model)
| Wall Mount Bracket | Wall Mount Bracket | Wall Mount Bracket | Wall Mount Bracket Cover |
| SZK-101 | SZK-102 | SZK-103 | SZK-104 |
![]() | ![]() | ![]() | ![]() |
| Wall Mount Bracket Cover | Ceiling Mount Bracket | Rubber Gasket | Rubber Gasket |
| SZK-105 | SZW-101 | SZW-102 | SZW-103 |
![]() | ![]() | ![]() | ![]() |
| Upper Bracket | NPT Bracket | NPT Bracket | NPT Bracket |
| SZP-101 | SZP-102 | SZP-103 | SZP-104 |
![]() | ![]() | ![]() | ![]() |
Notice to Customer
Thank you very much for purchasing our Patlite products.
- Request the installation and wiring be performed by a professional contractor if construction work is involved.
- Prior to installation, read this manual thoroughly before using this product to ensure correct use. In addition, please store this manual for future reference when performing maintenance, repairs or inspections.
- If there are any questions concerning this product, refer to the contact information at the end of this document and contact your nearest PATLITE Sales Representative.
To the Contractor
- Read this manual carefully prior to installation.
1 Read this First
NOTES TO BE OBSERVED FOR SAFE OPERATION
In order to prevent any damage to the user and other personnel or to assets, note the following:
■ The degree of harm and damage that will occur when misuse is made by ignoring the contents of the icons indicated is explained below.

Warning
Indicates an imminently dangerous condition: failure to follow the instructions may lead to death or serious injury.

Caution
Indicates a potentially dangerous condition: failure to follow the instructions may lead to slight injury or property damage.
Warning
- To prevent from damage, observe the following:
- Use this product in a properly maintained condition.
- Request the installation and wiring be performed by a professional contractor if construction work is involved. Failure to comply may result in fire, electric shock or falling from high places possible cause of failure may occur.
- When this product is used for security purposes, it should be inspected daily.
- After installation, do not use this product to climb up onto the equipment with. Failure to comply will result in product damage and/or falling off the machinery.
Caution
- Do not disassemble or remove during operation.
Notice
● Use a soft cloth, etc., dampened with water to wipe the product.
Do not use cleaners containing thinner benzine gasoline, oil, Chemicals, etc., to wipe with. It may result in discoloration and deterioration.
- To ensure safety when this optional part is installed into equipment, observe the following: - Do not, by any means, disassemble or modify this product.
2 Name and Dimensions
TYPE SZK-101
Unit: mm

| No. | Name | Material |
| 1 | Wall Mount Bracket | PC |
| 2 | Waterproof Sheet t = 1.0 | CR |


※ The Product Mounting Holes and Cable gland Mounting Holes are perforated.
Check 「Product Mounting with Knock-outs (11 page)」 for how to drill holes.
TYPE SZK-102
Unit: mm

| No. | Name | Material |
| 1 | Wall Mount Bracket | SUS |


TYPE SZK-103

| No. | Name | Material |
| 1 | Wall Mount Bracket | SUS |


TYPE SZK-104

Unit: mm
| No. | Name | Material |
| 1 | Wall Mount Bracket Cover | PC |
| Accessory | Material |
| Head Tapping Screw4×12 2 pcs. | SUS |


natural_image
Pure geometric curve diagram with no text, numbers, or symbolsTYPE SZK-105

| No. | Name | Material |
| 1 | Wall Mount Bracket Cover | PC |
| Accessory | Material |
| Head Tapping Screw5×16 2 pcs. | SUS |


line
| X | Y | |----|----| | 0 | 102 | | 1 | 98 | | 2 | 94 | | 3 | 88 | | 4 | 80 | | 5 | 70 | | 6 | 60 | | 7 | 50 | | 8 | 40 | | 9 | 30 | | 10 | 20 | | 11 | 10 | | 12 | 5 |TYPE SZW-101
Unit: mm

| No. | Name | Material |
| 1 | Ceiling Mount Bracket | SPCE |


TYPE SZW-102

Unit : mm
TYPE SZW-103

TYPE SZP-101

Product Mounting Hole 2 Places SF10-M□KT□/SL10-M□KT□
Product Mounting Hole 3 Places SF10-M□JN/SL10-M□JN SKH-M□J□/SKH-M□T□
单位:mm
| No. | Name | Material |
| 1 | Upper Bracket | PC |
| Accessory | Material |
| SiliconePole Waterproof | |
| PURWaterproof She |
TYPE SZP-102
Unit: mm

| No. | Name | Material |
| 1 | NPT Bracket | AL |
TYPE SZP-103

| No. | Name | Material |
| 1 | NPT Bracket | AL |
TYPE SZP-104
Unit : mm

| No. | Name | Material |
| 1 | NPT Bracket | AL |
3 Installation
Notice
- Ensure that the product is installed in an environment that meets the following conditions:
- Where excessive vibration is not present.
- On a sturdy surface. - On a level surface.
- When installing this product in an environment where waterproofing is required,
be sure to properly waterproof the exposed nuts and bolts. - Before use, be sure to read this manual as well as the instruction manual for the compatible PATLITE beacon.
TYPE SZK-101
Caution
- If using a cable gland, be sure that you are using it for the cable type beacons.
- Do not open unused mounting holes. If it is accidentally opened, be sure to waterproof the opening.
- Be sure to deburr after drilling.
- A cable gland with a mounting screw size of M16 x 20mm or less and cable size of 7 to 8mm is recommended.
Product Mounting with Knock-outs

natural_image
Technical line drawing of a mechanical component with internal cavities and mounting holes (no text or symbols)(SF10-KT/SL10-KT)

natural_image
Technical diagram of a mechanical component with two arrows indicating direction of movement (no text or symbols present)Product Mounting Hole (3 holes) (SF10-J/SL10-J/SKH)

natural_image
Cross-sectional diagram of a mechanical piston assembly (no text or labels)Cable gland Mounting HoleProduct Mounting H
□For Product Mounting Holes
Place the mounting bracket on a flat surface, with the bottom side up. Drill the holes from the bottom side.
| Model | Drill | Number of Holes |
| SF08-KT/SL08-KT | ∅5mm | 2 |
| SF10-KT/SL10-KT | ∅6mm | 2 |
| SF08-J/SL08-J/SKS | ∅5mm | 3 |
| SF10-J/SL10-J/SKH | ∅6mm | 3 |
□For Cable Gland
Drill a 16 hole from the top surface.
Cable gland Installation

natural_image
Technical line drawing of a mechanical component with no visible text or symbolsConnect a commercially available cable gland from the bottom of the Wall Mount Bracket. Install and fix in place with nuts from above.
Product Attachment
□3-screw Mounting Type
① Attach the Wall Mount Bracket to the wall, referring to the dimensions in the Mounting Dimensional Drawing below. (Screws are not included. Please prepare separately.)
② If using a cable gland, refer to Product Mounting with Knock-outs (page 11)".
③ If using a Rubber Gasket (SZW-102 / SZW-103), waterproofing is required.
(Refer to "Product Attachment (page 17)" for mounting instructions for the Rubber Gasket.)
④ Wire the product as shown on the right.
⑤ Insert the product bolt into the mounting hole of the Wall Mount Bracket.
⑥ Use the nuts and washer (accessory) to secure the product.
| Model | Nut | Recommend Torque |
| SF08/SL08/SKS | M4 | 0.7 N·m |
| SF10/SL10/SKH | M5 | 1.4 N·m |

With Cable Gland Without Cable Gland
3-screw Mounting Type
□2-point Hole Type Mounting
① Attach the Wall Mount Bracket to the wall, referring to the dimensions in the Mounting Dimensional Drawing below. (Screws are not included. Please prepare separately.)
② Using the mounting holes on the Wall Mount Bracket, secure the Mounting Bracket and Waterproof Sheet with screws and nuts. (Installation screws and nuts are not included with this product.)
| Model | Recommend Screw | Recommend Torque |
| SF08/SL08 | M4×20mm | 0.7 N·m |
| SF10/SL10 | M5×20mm | 1.4 N·m |
③ Wire the product as shown on the right.
④ Check that the O-ring is not twisted.
⑤ Align the indicators of the Mounting Bracket and the body of the beacon, then twist clockwise to lock in place.
(Read the applicable instruction manual for the locked state.)

2-point Hole Type Mounting
■Mounting Dimensional Drawing [Unit : mm]

| Screw / Nut | Recommend Torque |
| M5 | 1.4 N·m |
![PATLITE SZP-102 - ■Mounting Dimensional Drawing [Unit : mm] - 2](/content/2026/06/1249055/images/b9d970ad4ece426d7ecb082efa54783712319b54a514ce80cc0b60df4b2ef066.jpg)
Caution
- When using the Wall Mount Bracket (SZK-102) with a Rubber Gasket (SZW-102/SZW-103), the protection rating is IP23.
- If the rated voltage of the product to be installed exceeds 100V AC, use the Wall Mount Bracket Cover (SZK-104).
Product Attachment
□3-screw Mounting Type
① Attach the Wall Mount Bracket to the wall, referring to the dimensions in the Mounting Dimensional Drawing below. (Screws are not included. Please prepare separately.)
② Insert the product bolt into the mounting hole of the Wall Mount Bracket. ③ Use the nuts and washer (accessory) to secure the product.
| Model | Nut | Recommend Torque |
| SF08/SL08/SKS | M4 | 0.7 N·m |
| SF10/SL10/SKH | M5 | 1.4 N·m |

3-screw Mounting Type
□2-point Hole Type Mounting
① Attach the Wall Mount Bracket to the wall, referring to the dimensions in the Mounting Dimensional Drawing below. (Screws are not included. Please prepare separately.) ② Using the mounting holes on the Wall Mount Bracket, secure the Mounting Bracket and Waterproof Sheet with screws and nuts. (Installation screws and nuts are not included with this product.)
| Model | Recommend Screw | Recommend Torque |
| SF08/SL08 | M4×20mm | 0.7 N·m |
| SF10/SL10 | M5×20mm | 1.4 N·m |
③ Check that the O-ring is not twisted. ④ Align the indicators of the Mounting Bracket and the body of the beacon, then twist clockwise to lock in place. (Read the applicable instruction manual for the locked state.)

2-point Hole Type Mounting
■Mounting Dimensional Drawing [Unit : mm]

| Screw / Nut | Recommend Torque |
| 1.4 N·mM5 |
Caution
- If the rated voltage of the product to be installed exceeds 100V AC, use the Wall Mount Bracket Cover (SZK-105).
Product Attachment
□3-screw Mounting Type
① Attach the Wall Mount Bracket to the wall, referring to the dimensions in the Mounting Dimensional Drawing below. (Screws are not included. Please prepare separately.)
② Insert the product bolt into the mounting hole of the Wall Mount Bracket. ③ Use the nuts and washer (accessory) to secure the product.
| Model | Nut | Recommend Torque |
| SL15/SKP M8 6.0 N·m | ||

3-screw Mounting Type
□3-point Hole Type Mounting
① Attach the Wall Mount Bracket to the wall, referring to the dimensions in the Mounting Dimensional Drawing below. (Screws are not included. Please prepare separately.)
② Using the mounting holes on the Wall Mount Bracket, secure the Mounting Bracket and Waterproof Sheet with screws and nuts. (Installation screws and nuts are not included with this product.)
| Model | Recommend Screw | Recommend Torque |
| SL15 | M8×25mm | 6.0 N·m |
③ Check that the O-ring is not twisted. ④ Align the indicators of the Mounting Bracket and the body of the beacon, then twist clockwise to lock in place. (Read the applicable instruction manual for the locked state.)

3-point Hole Type Mounting
■Mounting Dimensional Drawing [Unit : mm]

| Screw / Nut | Recommend Torque |
| 2.4 N·mM6 |
TYPE SZK-104/SZK-105
Caution
- Attach the Wall Mount Bracket cover after attaching the product to the Wall Mount Bracket (SZK-102 / SZK-103). (Refer to "Product Attachment (page 13, 14)" for the mounting method of the Wall Mount Bracket.)
Wall Mount Bracket Attachment
① Remove the accessories attached to the Wall Mount Bracket Cover.
② Insert the Wall Mount Bracket Cover into the Wall Mount Bracket as shown in Figure 1.
③ Align the Mounting Holes on the Wall Mount Bracket and the Wall Mount Bracket Cover.
④ Secure the Wall Mount Bracket Cover with the screws provided.
| Model | Screw | Recommend Torque |
| SZK-102 | 4×12mm | 0.7 N·m |
| SZK-103 | 5×16mm | 1.4 N·m |

Figure 1

Figure 2

Caution
- After installing the product, fix the Ceiling Mount Bracket to the ceiling.
Product Attachment
□3-screw Mounting Type
① Insert the product bolt into the mounting hole of the Ceiling Mount Bracket.
② Use the nuts and washer (accessory) to secure the product.
| Model | Nut | Recommend Torque |
| SF10/SL10/SKH | M5 1.4 N·m | |
③ Attach the Ceiling Mount Bracket to the wall, referring to the dimensions in the Mounting Dimensional Drawing below. (Screws are not included. Please prepare separately.)

3-screw Mounting Type
□2-point Hole Type Mounting
① Using the mounting holes on the Ceiling Mount Bracket, secure the Mounting Bracket and Waterproof Sheet with screws and nuts. (Installation screws and nuts are not included with this product.)
| Model | Recommend Screw | Recommend Torque |
| SF10/SL10/SKH | M5×20mm or M5×14mm | 1.4 N·m |
② Check that the O-ring is not twisted.
③ Align the indicators of the Mounting Bracket and the body of the beacon, then twist clockwise to lock in place.
(Read the applicable instruction manual for the locked state.)
④ Attach the Ceiling Mount Bracket to the wall, referring to the dimensions in the Mounting Dimensional Drawing below. (Screws are not included. Please prepare separately.)

2-point Hole Type Mounting
■Mounting Dimensional Drawing [Unit : mm]

| Screw / Nut | Recommend Torque |
| 1.4 N·mM5 |
TYPE SZW-102/SZW-103
Product Attachment
① Align the opening of beacon base with the opening of the Rubber Gasket as shown below.

② Insert the product bolt into the mounting hole of the Rubber Gasket.
③ Use the nuts and washer (accessory) to secure the product.
SZW-102
| Model | Nut | Recommend Torque |
| SF08/SL08/SKS | M4 0.7 | N·m |
SZW-103
| Model | Nut | Recommend Torque |
| SF10/SL10/SKH | M5 1.4 | N·m |

■Mounting Dimensional Drawing [Unit : mm]
□SZW-102

□SZW-103

TYPE SZP-101
Pole Attachment
① Install the Pole Waterproof Ring to the bottom of the Upper Bracket. Check that the 2 ribs are on the outside.

② Insert the Pole into the Upper Bracket. Refer to the figure on the right. ( The Pole is sold separately. )
③ Tighten the Binding Head Tapping Screws (2 pcs.) from the topside of the Upper Bracket.
| Screw | Recommend Torque |
| 3×12mm | 0.8 N·m |

Product Attachment
□3-screw Mounting Type
① Wire the product as shown on the right. ② When use a Rubber Gasket (SZW-103), waterproofing is required. (Refer to "Product Attachment (page 17)" for the mounting method of the Rubber Gasket.)
③ Insert the product bolt into the mounting hole of the Upper Bracket. ④ Use the nuts and washer (accessory) to secure the product.
| Model | Nut | Recommend Torque |
| SF10/SL10/SKH | M5 1.4 N·m | |
※ The Waterproof Sheet is not required.(Accessory of Upper Bracket)

3-screw Mounting Type
□2-point Hole Type Mounting
① Wire the product as shown on the right. ② Using the mounting holes on the Upper Bracket, secure the Mounting Bracket and Waterproof Sheet with screws and nuts. (Installation screws and nuts are not included with this product.)
| Model | Recommend Screw | Recommend Torque |
| SF10/SL10/SKH | M5×20mm | 1.4 N·m |
③ Check that the O-ring is not twisted. ④ Align the indicators of the Mounting Bracket and the body of the beacon, then twist clockwise to lock in place. (Read the applicable instruction manual for the locked state.)

TYPE SZP-102/SZP-103/SZP-104
Pole Installation
① Install the Pole to the NPT Bracket. Tighten tightly!

Product Attachment
□3-screw Mounting Type
① Take out the wiring. ② If using a Rubber Gasket (SZW-102 / SZW-103), waterproofing is required.
(Refer to "Product Attachment (page 17)" for mounting instructions for the Rubber Gasket.)
③ Insert the bolts of the beacon into the mounting holes of the NPT Bracket.
④ Use the nuts (accessory) to secure the mounting surface of the NPT Bracket.
| Model | Nut | Recommended Torque |
| SF08/SL08/SKS | M4 | 0.7 N·m |
| SF10/SL10/SKH | M5 | 1.4 N·m |
| SL15/SKP | M8 | 6.0 N·m |

□2 - point Hole Leg Mounting Type 3 - point Hole Leg Mounting Type
① Using the mounting holes on the NPT Bracket, secure the Mounting Bracket and Waterproof Sheet with screws and nuts. (Installation screws are not included with this product. Binding head screws or pan head screws are recommended.)
| Model | Screw | Recommended Torque |
| SF08/SL08 | M4 | 0.7 N·m |
| SF10/SL10 | M5 | 1.4 N·m |
| SL15 | M8 | 6.0 N·m |
② Take out the wiring. ③ Check that the O-ring is not twisted. ④ Align the indicators of the Base and the body of the beacon, then twist clockwise to lock in place. ( Check the INSTRUCTION MANUAL for the lock state )

2 - point Hole Leg Mounting Type
4 Specifications
General Specifications (SZK-101)
| Product Name Wall Mount Bracket | ||
| Model | SZK-101 | |
| Applicable Models | SF08-M□KT□ | SF08-M□JN |
| SL08-M□KT□ | SL08-M□JN | |
| SKS-M□J | ||
| SF10-M□KT□ | SF10-M□JN | |
| SL10-M□KT□ | SL10-M□JN | |
| SKH-M□J□ | ||
| SKH-M□T□ | ||
| Mounting Location | According to the product to be installed. | |
| Mounting Direction | Upright | |
| Mass (Typ.) | 0.15kg | |
| Protection Rating | IP65(With product attachment) | SF08-M□KT□/SL08-M□KT□SF10-M□KT□/SL10-M□KT□ |
| IP65(When used with product and SZW-102 Rubber Gasket attachment) | SF08-M□JN/SL08-M□JN/SKS-M□J | |
| IP65(When used with product and SZW-103 Rubber Gasket attachment) | SF10-M□JN/SL10-M□JNSKH-M□J□/SKH-M□T□ | |
| IP23※(With product attachment) | SF08-M□JN/SL08-M□JN/SKS-M□JSF10-M□JN/SL10-M□JNSKH-M□J□/SKH-M□T□ | |
| Environmental Condition | Upright | |
| Remarks | There are no contents of controlled substances exceeding the threshold for the RoHS Directive.※ Excluding Terminal Block Opening of SKH-M□T. | |
General Specifications (SZK-102/103)
| Product Name Wall Mount Bracket | ||
| Model | SZK-102 | SZK-103 |
| Applicable Models | SF08-M□KT□ | SL15-M□KTN |
| SL08-M□KT□ | SL15-M□JN | |
| SF10-M□KT□ | SKP-M□J | |
| SL10-M□KT□ | ||
| SF08-M□JN | ||
| SL08-M□JN | ||
| SKS-M□J | ||
| SF10-M□JN | ||
| SL10-M□JN | ||
| SKH-M□J□ | ||
| SKH-M□T□ | ||
| Mounting Location | According to the product to be installed. | |
| Mounting Direction | Upright | |
| Mass (Typ.) | 0.19kg | 0.51kg |
| Protection Rating | IP23※(With product attachment) | |
| Environmental Condition | Upright | |
| Remarks | There are no contents of controlled substances exceeding the threshold for the RoHS Directive.※ Excluding Terminal Block Opening of SKH-M□T. | |
General Specifications (SZK-104/105)
| Product Name Wall Mount Bracket Cover | ||
| Model | SZK-104 | |
| Applicable Models | SZK-102 | |
| Mounting Location | According to the product to be installed. | |
| Mounting Direction | Upright | |
| Mass (Typ.) | 0.06kg(Accessory Remove) | |
| Protection Rating | IP23※(When used with product and SZK-102 Wall Mount Bracket) | |
| Remarks | There are no contents of controlled substances exceeding the threshold for the RoHS Directive.※ Excluding Terminal Block Opening of SKH-M□T. | |
General Specifications (SZW-101)
| Product Name Ceiling | Mount Bracket | ||
| Model | SZW-101 | ||
| Applicable Models | SF10-M☐KT☐ | SF10-M☐JN | |
| SL10-M☐KT☐ | SL10-M☐JN | ||
| SKH-M☐J☐ | |||
| SKH-M☐T☐ | |||
| Mounting Location | According to the product to be installed. | ||
| Mounting Direction | Upright / Inverted | ||
| Mass (Typ.) | 0.20kg | ||
| Protection Rating | IP20(With product attachment) | ||
| Environmental Condition | Upright / Inverted | ||
| Remarks | There are no contents of controlled substances exceeding the threshold for the RoHS Directive. | ||
General Specifications (SZW-102/SZW-103)
| Product Name Rubber | Gasket | ||
| Model | SZW-102 SZW-103 | ||
| Applicable Models | SF08-M□JN | SF10-M□JN | |
| SL08-M□JN | SL10-M□JN | ||
| SKS-M□J | SKH-M□J□ | ||
| SKH-M□T□ | |||
| Mounting Location | According to the product to be installed. | ||
| Mounting Direction | Upright | ||
| Mass (Typ.) | 0.03kg | 0.05kg | |
| Protection Rating | IP65(With product attachment) | ||
| Environmental Condition | Upright | ||
| Remarks | There are no contents of controlled substances exceeding the threshold for the RoHS Directive. | ||
General Specifications (SZP-101)
| Product Name Upper Bracket | ||
| Model | SZP-101 | |
| Applicable Models | SF10-M☐KT☐ | SF10-M☐JN |
| SL10-M☐KT☐ | SL10-M☐JN | |
| SKH-M☐J☐ | ||
| SKH-M☐T☐ | ||
| Corresponding Pole(※) | POLE22-0100AN / POLE22-0100ANK | POLE22-0100AT |
| POLE22-0300AN / POLE22-0300ANK | POLE22-0300AT | |
| POLE22-0500AN | POLE22-0500AT | |
| POLE22-0800AN / POLE22-0800ANK | POLE22-0800AT | |
| POLE22-1000AN | POLE22-1000AT | |
| Mounting Location | According to the product to be installed. | |
| Mounting Direction | Upright | |
| Mass (Typ.) 0.08kg(Accessory Remove) | ||
| Protection Rating | IP65(With product attachment) | SF10-M☐KT☐ / SL10-M☐KT☐ |
| IP65(When used with product and SZW-103Rubber Gasket attachment) | SF10-M☐JN / SL10-M☐JNSKH-M☐J☐ / SKH-M☐T☐ | |
| IP20(With product attachment) | SF10-M☐JN / SL10-M☐JNSKH-M☐J☐ / SKH-M☐T☐ | |
| Environmental Condition | Upright | |
| Remarks | There are no contents of controlled substances exceeding the threshold for the RoHS Directive. | |
※ When installing applicable options (sold separately), check our website (https://www.patlite.com)
General Specifications (SZP-102/103/104)
| Product Name NPT Bracket | ||||
| Model | SZP-102 SZP-104 | SZP-103 | ||
| Applicable Models | SF08-M□KT□ | SF10-M□KT□ | SL15-M□KTN | |
| SL08-M□KT□ | SL10-M□KT□ | SL15-M□JN | ||
| SF08-M□JN | SF10-M□JN | SKP-M□J | ||
| SL08-M□JN | SL10-M□JN | |||
| SKS-M□J | SKH-M□J□ | |||
| SKH-M□T□ | ||||
| Mounting Location | According to the product to be installed. | |||
| Mounting Direction | Upright | |||
| Mass (Typ.) 0.57kg | 0.36kg 1.32kg | |||
| Protection Rating IP20(With product attachment) | ||||
| Environmental Condition | Upright | |||
| Remarks | There are no contents of controlled substances exceeding the threshold for the RoHS Directive. | |||