DT6101SSA - Kitchen Appliances LG - Free user manual and instructions
Find the device manual for free DT6101SSA LG in PDF.
| Product Type | Built-in Microwave Oven |
| Model Number | DT6101SSA |
| Brand | LG |
| Color | Stainless Steel |
| Dimensions (W x H x D) | 23.8 x 13.7 x 18.5 inches |
| Oven Capacity | 1.6 cu. ft. |
| Weight | 45.2 lbs |
| Power Output (Microwave) | 1000 W |
| Power Output (Grill) | 1100 W |
| Power Output (Convection) | 1400 W |
| Voltage / Frequency | 120 V / 60 Hz |
| Control Type | Touch Control |
| Display Type | LED Display |
| Interior Light | Yes, LED |
| Turntable | Yes, Removable |
| Door Type | Pull-Down Drop-Down |
| Child Lock | Yes |
| Clock / Timer | Yes |
| Cooking Modes | Microwave, Grill, Convection, Combi |
| Defrost Function | Yes, by Weight/Time |
| Keep Warm Function | Yes |
| Auto Cook Menu | Yes, 30+ Recipes |
| Memory Function | Yes, 3 Favorite |
| Cleaning | Soft Cloth & Mild Detergent |
| Safety Features | Child Lock, Auto Shut-off, Interlock |
| Spare Parts Available | Door, Turntable, Rack, Glass Tray, Fuse |
| Repair Index | 6.5 / 10 |
Frequently Asked Questions - DT6101SSA LG
User questions about DT6101SSA LG
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Kitchen Appliances in PDF format for free! Find your manual DT6101SSA - LG and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. DT6101SSA by LG.
USER MANUAL DT6101SSA LG
Model Numbers
DT6101SAU
DT6101SSA
Instruction Manual
Instruction Manual Index
Recommendations and Suggestions....3 Characteristics 4 Installation 5 Use....7 Maintenance 8
Installation
The manufacturer will not be held liable for any damages resulting from incorrect or improper installation.
The minimum safety distance between the cooker top and the extractor hood is 650 mm.
Check that the mains voltage corresponds to that indicated on the rating plate fixed to the inside of the hood.
⚠ For Class I appliances, check that the domestic power supply guarantees adequate earthing.
Connect the extractor to the exhaust flue through a pipe of minimum diameter 120 mm. The route of the flue must be as short as possible.
Do not connect the extractor hood to exhaust ducts carrying combustion fumes (boilers, fireplaces, etc.).
If the extractor is used in conjunction with non-electrical appliances (e.g. gas burning appliances), a sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas. The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air.
Installation of the extractor hood over a solid-fuel burner (coal, wood, etc.) which could constitute a potential fire hazard (e.g. due to flying sparks) is only permitted if the burner is equipped with an enclosed, non-removable cover and all country-specific regulations are observed. This restriction does not apply to gas cookers and gas hobs.
⚠️ Regulations concerning the discharge of air have to be fulfilled.


USE
⚠ The extractor hood has been designed exclusively for household use to eliminate kitchen smells.
⚠️ Never use the hood for purposes other than for which it has been designed.
⚠️ Never leave high naked flames under the hood when it is in operation.
Adjust the flame intensity to direct it onto the bottom of the pan only, making sure that it does not engulf the sides.
Deep fat fryers must be continuously monitored during use: overheated oil can burst into flames.
The hood should not be used by children or persons not instructed in its correct use.
Do not use the appliance if it is damaged in any way.
⚠️ Never operate the extractor hood without a grease filter.
Do not flambe food directly under the extractor hood.
MAINTENANCE
Switch off or unplug the appliance from the mains supply before carrying out any maintenance work.
⚠ Clean and/or replace the Filters after the specified time period.
⚠ Clean the hood using a damp cloth and a neutral liquid detergent.
Defective bulbs should be replaced immediately to prevent the remaining bulbs from overloading.
There is a fire risk if cleaning is not carried out in accordance with the instructions.
Dimensions

Components
| Ref. | Q.ty | Product | Components |
| 1 | 1 | Hood | Body, complete with: Controls, Light, Blower, Filters |
| 8 | 1 | Directional Air Outlet grille | |
| 9 | 1 | Flange ø 150 mm | |
| 10a | 1 | Reducer Flange ø 150-120 mm | |
| 10b | 1 | Damper | |
| 20 | 1 | Closing | element |
Ref. Q.ty Installation Components
| 12a 4 Screws 3,5 x 16 |
| 12e 2 Screws 2,9 x 12,7 |
| 12f 5 Screws 2,9 x 9,5 |
| Q.ty | Documentation |
| 1 | Instruction Manual |

Drilling the Support Surface and Fitting the Hood
- The Hood can be fitted directly on the lower surface of the Wall Units (650 mm min. above the Cooker Top) using the snap-on Side Supports.
- Make an opening on the lower surface of the Wall Unit, as indicated. (fig.1)
- Choose the correct flange measure based on the air outlet diameter and insert it into the upper air outlet opening. (fig.2)
- Screw the closing profile 20 onto the rear part of the hood, using the screws 12f (2.9 x 9.5) provided. (fig.3)
- Open the sliding suction panel.
- Remove the metal grease filters one by one after having disconnected the relative fastening elements.
- Close the sliding suction panel again.
- Insert the Hood until the snap-on side supports click into place. (fig.4)
- Open the sliding suction panel.
- Lock in position by tightening the screws Vf from underneath the hood. (fig. 4)
- If necessary, adjust the whole filter holder unit and proceed as follows:
- Loosen the four adjustment screws Vr and close the sliding panel again. (fig. 5)
- Move the entire filter holder unit until it is properly aligned with the wall unit. (fig. 6)
- Keeping the hood canopy still, open the sliding panel and lock the adjustment screws again. (fig. 5)
- The hood can now be fastened to the wall unit using the four screws 12a (3.5 x 16) provided. (fig. 7)
- Replace the metal grease filters.
- Close the sliding suction panel again.

3



Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the chimney using either a flexible or rigid pipe of diameter 150 or 120 mm, the choice of which is left to the installer.
• Install the flange of diameter 150 mm (9). • Install the damper (10b) of diameter 150 on the flange of diameter 150 (9).
To install a diameter 120
• Install a reducer flange (10a) on the damper (10b). - Fix the pipe in position using sufficient pipe clamps (not supplied). - Remove any activated charcoal filters.


RECIRCULATION VERSION AIR OUTLET
- Cut a hole φ 155 mm in the wall unit over the hood.
- Insert the flange 9 on the hood body outlet.
- Connect the hood body outlet to the top part of the wall unit using a rigid or flexible pipe ø 150 mm, to be selected by the installer.
- Fix the pipe in position using sufficient pipe clamps (not supplied).
- Fix the directional grille 8 on the recirculation air outlet using the 2 screws 12e (2.9 x 9.5) provided.
- Ensure that the activated charcoal filters have been inserted.

ELECTRICAL CONNECTION
- Connect the hood to the mains through a two-pole switch having a contact gap of at least 3 mm.

By pulling out the sliding panel it is possible to automatically activate all the hood functions. By simply closing the sliding panel all the functions are switched off.
SWITCH FUNCTIONS
L Light Switches the lighting system on and off
M Motor Switches the extractor motor on and off
- Low speed, used for a continuous and silent air change in the presence of light cooking vapour.
- Medium speed, suitable for most operating conditions, thanks to an optimum relation between hood performance and noise.
- Maximum speed, suitable when the highest cooking vapour emission has to be eliminated for longer periods.
Grease filters
CLEANING METAL CASSETTE GREASE FILTERS
- The filters must be cleaned every 2 months, or more frequently in case of particularly heavy use of the hood. Filters can be washed in a dishwasher. • Pull out the sliding suction panel.
- Remove the filters one by one, after having disconnected the relative fastening elements.
- Wash the filters, taking care not to bend them. Let them get dry before refitting them. (The colour of the filter surface may change throughout the time but this has no influence to the filter efficiency).
- When refitting the filters, make sure that the handle is visible on the outside.
- Close the sliding suction panel.
Charcoal filter (Recycling version)
REPLACING CHARCOAL FILTERS
- These filters are not washable and cannot be regenerated, and must be replaced approximately every four months or more frequently by particularly heavy use. • Pull out the sliding suction panel.
- Remove the grease filters.
- Remove the saturated carbon filter by releasing the fixing hooks
- Replace the grease filters.
- Close the sliding suction panel.


Light Replacement
20 W Halogen lamp.
- Remove the metal terminals fixing the metal panel.
- Slide the metal panel out of one of the fastening clips. Lower the unfastened part of the panel slightly, so that it can be completely removed. Extract the lamp from the support.
- Replace with another of the same type, making sure that the two pins are properly inserted in the lamp holder socket holes.
- Replace the metal panel in reverse order.
When switched on, the halogen bulbs become very hot. Even for some time after the bulbs have been switched off there is still a risk of burns.