DRU 1 - Measurement PCE Instruments - Free user manual and instructions
Find the device manual for free DRU 1 PCE Instruments in PDF.
User questions about DRU 1 PCE Instruments
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Measurement in PDF format for free! Find your manual DRU 1 - PCE Instruments and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. DRU 1 by PCE Instruments.
USER MANUAL DRU 1 PCE Instruments
text_image
PCE REFRACTOEMETER 3.5 2 2.3 °C 1.3392 DIGITAL REFRACTOMETER PCE-DRD 2User Manual
PCE-DRD / DRF / DRG Series | Refractometer

text_image
QR code image containing encoded data, no visible human-readable textUser manuals in various languages (français, italiano, español, português, nederlands, türk, polski, русский, 中文) can be found by using our product search on: www.pce-instruments.com
Last change: 2 January 2025 v1.0
Contents
1 Safety notes.... 1
2 Technical specifications .... 2
3 Delivery scope.... 3
4 Description .... 4
5 Display 5
6 Measurement....6
6.1 Power on....6
6.2 Measurement....7
6.3 Power off....8
7 Calibration 9
8 Maintenance .... 11
9 Contact....12
10 Disposal 12
1 Safety notes
Please read this manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel. Damage or injuries caused by non-observance of the manual are excluded from our liability and not covered by our warranty.
- The device must only be used as described in this instruction manual. If used otherwise, this can cause dangerous situations for the user and damage to the meter.
- The instrument may only be used if the environmental conditions (temperature, relative humidity, ...) are within the ranges stated in the technical specifications. Do not expose the device to extreme temperatures, direct sunlight, extreme humidity or moisture.
- Do not expose the device to shocks or strong vibrations.
• The case should only be opened by qualified PCE Instruments personnel.
- Never use the instrument when your hands are wet.
- You must not make any technical changes to the device.
- The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner, no abrasives or solvents.
• The device must only be used with accessories from PCE Instruments or equivalent.
- Before each use, inspect the case for visible damage. If any damage is visible, do not use the device.
- Do not use the instrument in explosive atmospheres.
- The measurement range as stated in the specifications must not be exceeded under any circumstances.
- Non-observance of the safety notes can cause damage to the device and injuries to the user.
We do not assume liability for printing errors or any other mistakes in this manual.
We expressly point to our general guarantee terms which can be found in our general terms of business.
2 Technical specifications
| Model | Parameters | Measurement range | Refractive index |
| PCE-DRD 1 | Salt content | 0 ... 28 % | 1.3330 ... 1.4200 nD |
| PCE-DRD 2 | Salt content | 0 ... 280 ‰ | 1.3330 ... 1.4200 nD |
| PCE-DRD 3 | Salt content | 0 ... 28,5 % | 1.3330 ... 1.4200 nD |
| PCE-DRF 2 | Acetic acid | 0 ... 75 % | 1.3270 ... 1.3770 nD |
| PCE-DRF 3 | Calcium chloride | 0 ... 41 % | 1.3330 ... 1.4200 nD |
| PCE-DRF 4 | Glycerine | 0 ... 100 % | 1.3330 ... 1.4740 nD |
| PCE-DRF 5 | Hydrogen peroxide | 0 ... 61 % | 1.3330 ... 1.4650 nD |
| PCE-DRF 6 | Potassium carbonate | 0 ... 51 % | 1.3330 ... 1.4650 nD |
| PCE-DRF 7 | Potassium hydroxide | 0 ... 21 % | 1.3330 ... 1.3744 nD |
| PCE-DRF 8 | Lithium hydroxide | 0 ... 15 % | 1.3330 ... 1.4641 nD |
| PCE-DRF 9 | Methanol | 0 ... 46 % | 1.3330 ... 1.3290 nD |
| PCE-DRG 1 | Magnesium chloride | 0 ... 35 % | 1.3330 ... 1.4650 nD |
| PCE-DRG 2 | Sodium nitrate | 0 ... 41 % | 1.3127 ... 1.3870 nD |
| PCE-DRG 3 | Ammonia | 0 ... 35 % | 1.3330 ... 1.3840 nD |
| PCE-DRG 4 | Isopropyl alcohol | 0 ... 81 % | 1.3330 ... 1.4650 nD |
| PCE-DRG 5 | Dimethylacetamide | 0 ... 100 % | 1.3270 ... 1.4472 nD |
| PCE-DRG 6 | Dimethylformamide | 0 ... 55 % | 1.3260 ... 1.4039 nD |
| PCE-DRG 7 | Dimethylformamide | 0 ... 100 % | 1.3260 ... 1.4320 nD |
| PCE-DRG 8 | N-methyl-2-pyrrolidone | 0 ... 100 % | 1.3260 ... 1.4800 nD |
| PCE-DRG 9 | Sodium hypochlorite | 0 ... 18 % | 1.3250 ... 1.4000 nD |
| PCE-DRG 10 | Sodium hydroxide | 0 ... 55 % | 1.3250 ... 1.4410 nD |
| Resolution and accuracy of all refraction parameters | |||
| Resolution | 0.1 % | ||
| Accuracy | ±0.2 % | ||
| Resolution and precision of the refractive index | |||
| Resolution | 0.0001 nD | ||
| Accuracy | ±0.0003 nD | ||
| Temperature | |||
| Range | 0 ... 40 °C | ||
| Resolution | 0.1 °C | ||
| Accuracy | ±0.5 °C | ||
| Temperature compensation | Automatic 10 ... 40 °C | ||
| Further specifications | |
| Sampling rate | 1 Hz |
| Sample quantity | 0.2 ... 0.3 ml |
| Display | LCD |
| Automatic power-off | 60 seconds |
| IP protection | IP65 |
| Capacity | 5 V DC / 500 mA |
| Operating conditions | 0 ... 50 °C / 0 ... 95 % RH |
| Storage conditions | 0 ... 50 °C / 0 ... 95 % RH |
| Dimensions | 145 x 46 x 27 mm |
| Weight | 115 g |
3 Delivery scope
1 x refractometer
1 x pipette
1 x plastic case
1 x USB-A - USB-C cable (for charging only, mains adaptor not included)
1 x user manual
4 Description

text_image
Sample groove Housing Display Key USB-C interface5 Display

text_image
Temperature compensation Sample temperature -1.88.8 -1.88.8 °C -1.88.88 Measured value Refractive index Battery level Key
Note
Icon is displayed when the refractometer needs to be charged.
6 Measurement
6.1 Power on
Press the key to start the refractometer. After switching on, the device automatically starts a measurement.

text_image
Sample temperature 20.8 °C If there is no sample in the sample groove, the display shows "---". Start key6.2 Measurement
After switching on the refractometer, remove the previous sample and dry the sample groove.

natural_image
Close-up of a white electronic device with a circular lens and curved top (no text or symbols visible)Press the key again. The refractometer carries out a new measurement and displays the value on the screen.
Please note that the temperature is automatically compensated.
If the measurement range is exceeded, the display shows "H H H" if the upper range is exceeded and "L L L" if the lower range is exceeded.

text_image
Measured value 2.18 20.8°C 1.3668 Display when the range is exceeded Press the key again to start a new measurement.Please note the following information:
- If you use the refractometer outdoors, avoid bright light so as not to impair the accuracy of the measurement.
- Before inserting the sample, clean the slit of the sample chamber thoroughly with a soft cloth or paper towel.
- Keep the refractometer in a stable environment for the measurements.
6.3 Power off
The refractometer switches off automatically after 1 minute of inactivity.
7 Calibration
You can calibrate the refractometer with distilled water. The calibration method is as follows:
Add 0.2 - 0.3 ml of distilled water to the sample groove.

text_image
CAL 20.8°C YESYES" flashes on the display. Wait for confirmation
Press the key for about two seconds to call up the calibration menu.
Press the key again to confirm the start of calibration.
Once the calibration process is complete, the display shows the following:

text_image
RTC End 20.8°CNote If you do not confirm the start of the calibration process with the key, the device returns to measuring mode after 10 seconds.
However, if the calibration process fails, the display shows how much is still missing:

text_image
RTC - 20.8 °C8 Maintenance
Remove the sample at the end of a measurement, rinse the sample groove with water and dry it with a soft cloth or paper towel.

natural_image
3D rendered image of a handheld electronic device with a small screen and a tip, no visible text or symbols.Store the refractometer in a dry place and do not expose it to direct sunlight. Moisture and high temperatures can damage the device.

natural_image
Illustration of a stylized human figure emerging from a device with radiating lines (no text or symbols)Clean the refractometer carefully after each use and store it in its case.

natural_image
Illustration of a hand cleaning a white electronic device with a cloth (no text or symbols visible)9 Contact
If you have any questions, suggestions or technical problems, please do not hesitate to contact us. You will find the relevant contact information at the end of this user manual.
10 Disposal
For the disposal of batteries in the EU, the 2006/66/EC directive of the European Parliament applies. Due to the contained pollutants, batteries must not be disposed of as household waste. They must be given to collection points designed for that purpose.
In order to comply with the EU directive 2012/19/EU we take our devices back. We either re-use them or give them to a recycling company which disposes of the devices in line with law.
For countries outside the EU, batteries and devices should be disposed of in accordance with your local waste regulations.
If you have any questions, please contact PCE Instruments.

text_image
Pb www.pce-instruments.com


PCE Instruments contact information
Germany France Spain
PCE Deutschland GmbH PCE Instruments France EURL PCE Ibérica S.L.
Im Langel 26 23, rue de Strasbourg Calle Mula, 8
D-59872 Meschede 67250 Soultz-Sous-Forets 02500 Tobarra (Albacete)
Chester Rd, Old Trafford
Manchester M32 0RS
United Kingdom
Tel: +44 (0) 161 464902 0
Fax: +44 (0) 161 464902 9
info@pce-instruments.co.uk
www.pce-instruments.com/english
Italy
PCE Italia s.r.l.
Via Pesciatina 878 / B-Interno 6
55010 Loc. Gragnano Pehlivan Sok. No.6/C
Capannori (Lucca)
Italia
www.pce-instruments.com/turkish
The Netherlands
PCE Brookhuis B.V.
Institutenweg 15
7521 PH Enschede
Nederland
Telefoon: +31 (0)53 737 01 92
info@pcebenelux.nl
www.pce-instruments.com/dutch Fax: +1 (561) 320-9176
info@pce-americas.com
www.pce-instruments.com/us
United States of America
PCE Americas Inc.
1201 Jupiter Park Drive, Suite 8
Jupiter / Palm Beach
33458 FL
USA
Tel: +1 (561) 320-9162
Denmark
PCE Instruments Denmark ApS
Birk Centerpark 40
7400 Herning
Denmark