PCE Instruments

TC 26 - Measurement PCE Instruments - Free user manual and instructions

Find the device manual for free TC 26 PCE Instruments in PDF.

📄 7 pages English EN Download 💬 AI Question
Notice PCE Instruments TC 26 - page 2
Pick your language and provide your email: we'll send you a specifically translated version.

User questions about TC 26 PCE Instruments

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Measurement in PDF format for free! Find your manual TC 26 - PCE Instruments and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. TC 26 by PCE Instruments.

USER MANUAL TC 26 PCE Instruments

The PCE-TC 26 infrared thermal imager adopts the display method of infrared thermal imaging, which can measure the temperature of each pixel of the target object and capture the state of the object more clearly.

KEYS AND FUNCTIONAL DESCRIPTION

PCE Instruments TC 26 - KEYS AND FUNCTIONAL DESCRIPTION - 1

text_image Display screen Enter / Home Direction Return/ On/Off Red-Laser Infrared camera Trigger USB Type-C

»Charging indication:

USB Type-C interface is used for charging. During charging, the display screen is normally on and display the current power volume.

On/Off:

Short press POWER to power on or long press POWER to power off.

»Photographing and video recording:

Short press TRIGGER in power-on state to photograph, or long press TRIGGER to record videos.

»Data transmission:

When connecting with a computer through the USB Type-C wire, the thermal imager can generate the USB drive and copy photos/videos through the Windows system.

FUNCTIONAL DESCRIPTION

1. On/Off

Short press POWER in power-off state to power on or long press POWER in power-on state to power off.

2. Main interface

Press LEFT and RIGHT on this interface to switch the palette, or press UP and DOWN to switch the function of visible light imaging or infra red imaging.

Short press TRIGGER to photograph or long press TRIGGER to record videos.

Press POWER on this interface to light off the screen and save power or press any keys to light on the screen again and enter the interface.

Press OK to display the following menu interface:

PCE Instruments TC 26 - Main interface - 1

text_image High temperature tracking 49.9°C 35.4°C Low temperature tracking 28.4°C Description of selected icons Powervolume Center point tracking Palette bar Secondary menu Primary menu

After the primary menu pops up, select a function with LEFT and RIGHT, press OK to pop up the secondary menu. Press POWER to return to the main interface.

After entering the secondary menu, select a function with LEFT and RIGHT, press OK to confirm the selected function, and press POWER to return to the primary menu. Both photographing and video recording are valid on this interface.

3. Photographing and video recording

Short press TRIGGER to photograph (image format: jpg).

Long press TRIGGER to record videos (video formal: mp4).

4.Album

Press OK on the main interface to pop up the primary menu, select the album with LEFT and RIGHT, press OK to enter the album.

All the pictures and videos in the album are arranged in the shooting time.

Select the pictures or videos with UP and DOWN, press OK for fullscreen display or play.

Press UP and DOWN in the display or play state to switch the previous or next file.

After play or pressing POWER, return to the album list interface.

SYSTEM SETTINGS

Option Description of system settings
Language switch Chinese (Simplified), Chinese (Traditional), English, French, German, Spanish, Russian, Dutch, Japanese, Korean and Arabian
Emissivity 0.01 ... 0.99
Unit switch Degree centigrade, Fahrenheit and Kelvin
Temperature alarm (On/Off) settingSelect the upper/lower limit alarm or set the alarm value
Storage settings View the internal storage situation and formatting
Date and time Time setting: Year/month/day/hour
Auto OFF Set the auto OFF time if there is no operation for a long time
Palette bardisplay switch Whether the screen palette bar is displayed
Screen brightness Screen brightness (adjustable)
Factory reset Whether to reset the factory data (optional)

PALETTE

To optimize different scenarios and facilitate observing different target objects, the thermal imager comprises 8 common palettes.

PCE Instruments TC 26 - PALETTE - 1

TEMPERATURE MEASUREMENT MODE

» Conventional temperature measurement

Support temperature measurement at the center point as well as continuous high/low temperature tracking

»Regional temperature measurement

Choose some regions for center point and high/low temperature tracking and lest, or zoom in/out the temperature measurement region for different scenarios.

LASER

Pressing OK on the main screen will bring up a primary menu.

Selecting LEFT or RIGHT will access the submenu where you can choose the Laser function.

Press OK to activate it. Once activated, press OK again to deactivate the laser.

TECHNICAL PARAMETERS

Handheld thermal imaging
Resolution 120 x 90
Working band 8 ... 14 μm
Frame rate 25 Hz
NETD <60 mK @ 25 °C
Field angle H=38° / V=50°
Emissivity 0.01 ... 0.99
Temperature measurement rangeLow temperature: -10 ... 160 °CHigh temperature: 160 ... 400 °C
Temperature measurement accuracy±2 °C or ±2 % of the reading
Screen size 2.8 inches
Palette Iron red, white heat, blackheat, rainbow, red heat, high contrast, green heat and lava
Temperature measurementSupport full-screen temperature measurement of highest/lowest/ center point and mild region
Laserlevel Class II
General
Language Chinese (Simplified), Chinese (Traditional), English, French, German, Spanish, Russian, Dutch, Japanese, Korean and Arabian
Interface USB Type-C (support charging and data transmission)
Battery 2600mAh lithium battery
Capacity 8G internal memory
Picture storage format JPG
Video format MP4
Working time 4 hours if the battery is fully charged
Working temperature -10 ... 50 °C
Storage temperature -40 ... 85 °C
Net weight 300 g
Product dimension 219 x 72 x 66 mm

DISPOSAL

For the disposal of batteries in the EU, the (EU) 2023/1542 directive of the European Parliament applies. Due to the contained pollutants, batteries must not be disposed of as household waste. They must be given to collection points designed for that purpose. In order to comply with the EU directive 2012/19/EU we take our devices back. We either re-use them or give them to a recycling company which disposes of the devices in line with law. For countries outside the EU, batteries and devices should be disposed of in accordance with your local waste regulations. If you have any questions, please contact PCE Instruments.

PCE INSTRUMENTS CONTACT INFORMATION

Germany France Spain

PCE Deutschland GmbH PCE Instruments France EURL PCE Ibérica S.L.

Im Langel 26 23, rue de Strasbourg Calle Mula, 8

D-59872 Meschede 67250 Soultz-Sous-Forets 02500 Tobarra (Albacete)

Chester Rd, Old Trafford

Manchester M32 ORS Capannori (Lucca)

United Kingdom

Tel: +44 (0) 161 464902 0

Fax: +44 (0) 161 464902 9

info@pce-instruments.co.uk

www.pce-instruments.com/english

Italy

PCE Italia s.r.l.

Via Pesciatina 878 / B-Interno 6

55010 Loc. Gragnano

Pehlivan Sok. No.6/C

Türkiye

Tel: 0212 471 11 47

www.pce-instruments.com/turkish

The Netherlands

PCE Brookhuis B.V.

Twentepoort West 17

7609 RD Almelo

Nederland

Telefoon: +31 (0)53 737 01 92

info@pcebenelux.nl

www.pce-instruments.com/dutch

United States of America

PCE Americas Inc.

1201 Jupiter Park Drive, Suite 8

Jupiter / Palm Beach

33458 FL

USA

Tel: +1 (561) 320-9162

Fax: +1 (561) 320-9176

info@pce-americas.com

www.pce-instruments.com/us

Denmark

PCE Instruments Denmark ApS

Birk Centerpark 40

7400 Herning

Denmark

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : PCE Instruments

Model : TC 26

Category : Measurement