CPD1200EILCD - Inverter CyberPower - Free user manual and instructions
Find the device manual for free CPD1200EILCD CyberPower in PDF.
User questions about CPD1200EILCD CyberPower
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Inverter in PDF format for free! Find your manual CPD1200EILCD - CyberPower and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. CPD1200EILCD by CyberPower.
USER MANUAL CPD1200EILCD CyberPower
1 IMPORTANT SAFETY INSTRUCTIONS......4
2 INSTALLATION....5
2-1 Unpacking....5
2-2 Product Overview & Outlook....5
2-3 Power Requirements of Your Equipment....7
2-4 Hardware Installation Guide....7
3 DEFINITIONS FOR ILLUMINATED LCD INDICATORS......9
Power On/Off....11
Function Setup....11
Audible Alarm....11
Function Setup Guide....11
5 TROUBLESHOOTING....14
6 TECHNICAL SPECIFICATIONS....16
1 IMPORTANT SAFETY INSTRUCTIONS
(SAVE THESE INSTRUCTIONS)
Before attempting to unpack, install, or operate the product, please read and follow all instructions carefully.
CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area free of conductive contaminants. (Please see Technical Specifications section for acceptable temperature and humidity range.)
CAUTION! The product must be installed in a protected environment away from heat-emitting appliances such as a radiator or heat register. The location should provide adequate air flow around the product for proper ventilation.
CAUTION! To reduce the risk of injury, use cables come with the product. Use appropriate and certified external battery cables.
CAUTION! To reduce risk of damage and injury, use batteries with good quality.
CAUTION! Risk of electric shock. DO NOT remove the cover. No user serviceable parts inside.
CAUTION! Provide adequate ventilation for the battery compartment. The battery enclosure should be designed to prevent accumulation and concentration of hydrogen gas at the top of the compartment.
CAUTION! A battery can present a risk of electrical shock and high short circuit current. When working on batteries, remove watches, rings, or other metal objects. Use tools with insulated handles.
CAUTION! Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected.
CAUTION! To avoid electrical shock, turn off the unit and unplug it from the AC power source before installing equipment or servicing the battery. Servicing the battery can only be performed by trained personnel.
DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT! Do not use in any circumstance that would affect the operation and safety of life support equipment, medical applications, or patient care.
DO NOT USE WITH OR NEAR AQUARIUMS! To reduce the risk of fire or electric shock, do not use with or near an aquarium. Condensation from the aquarium can cause the unit to short out.
DO NOT USE THE PRODUCT ON ANY TRANSPORTATION! To reduce the risk of fire or electric shock, do not use the unit on any transportation such as airplanes or ships. The effect of shock or vibration caused during transit and the damp environment can cause the unit to short out.
2 INSTALLATION
2-1 Unpacking
Inspect the product upon receipt. The box should contain the following:
(a) This product; (b) User Manual; (c) Input Power Cord

natural_image
3D geometric diagram of a hexagonal prism with internal grid pattern (no text or symbols)Power inverter

natural_image
Simple line drawing of an open book with blank pages (no text or symbols)User Manual

natural_image
Pure diagram of a twisted rope or cable with no text, numbers, or symbolsInput Power Cord
2-2 Product Overview & Outlook
CyberPower Power Inverter ensures home/office users the always-on power supply with the exceptional power performance. Featuring the high-efficiency conversion design, the Power Inverter supplies long-lasting and reliable power to various appliances and provide longer backup for equipment. These units can be installed in either a horizontal or wall-mounted placement to make the most of your space.
CPD1200EILCD

text_image
CyberPower ① ② ③
text_image
Diagram of a device rear panel with labeled components including fan, socket, and indicator lights- Multifunction LCD Readout
- Power On/off Switch
- Function Buttons
- AC Inlet
- DC Input Cable(Red "+")
- DC Input Cable(Black "-"')
- AC Outlet
Application Diagram

flowchart
graph TD
A["Light / Lamp"] --> B["Desktop PC"]
B --> C["CyberPower Power Inverter with external battery pack"]
D["Standing Fan"] --> C
E["TV"] --> C
2-3 Power Requirements of Your Equipment
-
Ensure that the equipment plugged into the AC outlet does not exceed the product's rated capacity (1200VA/900W for CPD1200EILCD). If rated unit capacities are exceeded, an overload condition may occur and cause the unit to shut down or the circuit breaker trip.
-
There are many factors that can affect the amount of power that your appliances will require. For optimal system performance keep the load below 80% of the unit's rated capacity.
2-4 Hardware Installation Guide
Step 1 Connect the Battery
For optimal battery life and reasonable recharging time, make sure the batteries capacity no less than 100Ah. Use batteries with same brand, type, and capacity.
Connect DC input cables of this product to external batteries:
Red “+” cable to the battery's Positive “+” polarity
Black “-” cable to the battery’s Negative “-” polarity
Single Battery Connection
Single battery voltage must be equal to DC voltage of the unit.

text_image
DC BreakerMultiple Batteries Connection – in Series
Connect two batteries in series can double the voltage. Sum of voltages must be equal to DC voltage of the unit.

natural_image
Diagram showing two square boxes connected by a curved line to a 3D octagonal panel with internal grid pattern (no text or symbols)Multiple Batteries Connection – in Parallel
Connect multiple batteries in parallel can increase total battery capacity but still keep terminal voltage as single battery voltage.

natural_image
Technical line drawing of a door frame with four square components and a diagonal hatching pattern (no text or symbols)Step 2 Connect the Product to Utility
Connect the product to a wall outlet. Charging the battery for at least 8 hours is recommended to ensure that the battery's maximum charge capacity is achieved. To recharge the battery and maintain optimal battery charge, simply leave the unit plugged into a wall outlet at all times. The battery can be charged whether the unit is turned on or off.
DO NOT connect Neutral of the Power Distribution Box to (a) the OUTPUT Neutral of this product, or (b) the INPUT Neutral of connected equipment. Otherwise, reversed polarity will damage the product and connected equipment.

flowchart
graph TD
A["Utility power"] --> B["L"]
A --> C["N"]
A --> D["G"]
B --> E["Inverter"]
C --> E
D --> E
E --> F["Load"]
G["Common Neutral"] --> E
H["X"] --> I["Ground"]
Step 4 Connect the Load
Connect the load to the unit's outlet. Make sure that the total loads of your appliances are below 80% of the unit's rated capacity.
3 DEFINITIONS FOR ILLUMINATED LCD INDICATORS
LCD Display

text_image
I/P O/P PV BATT. KVA MkWh Default Min A Hz % K$ °CThe left half of the LCD screen displays the energy flow direction and the status of the Power Inverter. The right half of the LCD screen displays the input, output, and battery information.
| Icon | Description |
![]() | Normal Mode (Power On)The Power Inverter is turned on. |
![]() | Standby Mode (Power Off)The Power Inverter is off while the LCD display remains on. |
![]() | Utility PowerUtility power source supplies AC power. |
![]() | Load CapacityThe approximate load capacity of the unit's outlet. (in 25% increments) |
![]() | Battery CapacityThe approximate battery capacity and charging status. (in 25% increments) |
![]() | FaultThis icon appears if there is a problem with the unit. |
![]() ![]() | OverloadThis icon appears and an alarm sounds to indicate the outlet is overloaded.MuteThis icon appears whenever the unit is in silent mode. However, when there is a problem with the unit, the alarm will still beep even in silent mode. |
![]() | Setup ModeThis icon appears whenever the unit is in Setup Mode. |
| I/P O/P PV BATT. | Input / Output / Battery InformationIt indicates input, output, and battery information. |
Operation Modes
There are three types of modes regarding to the operation of the Power Inverter. The corresponding LCD displays are as shown below.
| LCD Display | Operation Mode |
![]() | Standby ModeIn Standby Mode, the Power Inverter is off and the Utility power bypasses to output and in the meantime charges the battery. The LCD is on to show battery status. |
![]() | Line ModeThe Power Inverter is turned on and AC input power is normal. It supplies power to the load (connected equipment). |
![]() | Battery ModeDuring a severe brownout or blackout, the Utility Power is absent and the Power Inverter switches to Battery Mode. The battery will supply power to the load (connected equipment). |
Power On: Press the POWER button to turn on the unit.
Power Off: Press the POWER button again to turn off the unit.

text_image
Setup Power SelectFunction Setup
Press the SETUP button for 4 seconds to access the setup mode's 9 functions: Audible Alarm, Input Voltage Range, Utility Charging Current, Auto Restart Voltage, Low Battery Shutdown Voltage, LCD Auto Sleep, Cycling Display, Back to Default, and Return to Status Display. Short press the SELECT button to view the functions. When a function is selected, short press the SETUP button to access the function's options. Short press SELECT button to view the options. When the desired option is selected, short press SETUP button to confirm the setting. The unit will leave Setup Mode if there is no operation in 60 seconds.
Audible Alarm
Press SELECT button for 2 seconds to enable the audible alarm (beeps once) or disable (beeps twice) the audible alarm. The MUTE icon will appear on the LCD display when the audible alarm is disabled.
Function Setup Guide
| Function | Options | Default | Description |
Page 1 - Audible Alarm![]() | OnOffESC | On | If Off is selected, the unit will mute alarms and the Mute icon will appear on the LCD display. |
Page 2 – Input Voltage Range![]() | Hi (Wide):(90-280Vac)Lo (Narrow):(170-280Vac)ESC | Hi | For connected equipment that are less sensitive to the fluctuation of voltage range, set the input voltage range wider and the output voltage will follow.For connected equipment that are sensitive to the fluctuation of voltage range, narrow the input voltagerange.Note: The transfer time will increase while the input voltage gets lower. If the connected equipment is sensitive to the transfer time, power interruption condition may occur. |
Page 3 – Utility Charging Current![]() | 10/15/20AESC | 20A | With different battery capacity, adjust utility charging current to provide optimal recharging time.Recommended setting:10A for 100Ah battery15A for 150Ah battery20A for 200Ah battery |
Page 4 – Auto Restart Voltage![]() | Any/10.5/11.0//11.5/12.0/12.5/13.0/FULESC | Any | When the utility power comes back and starts to charge the battery, the Power Inverter will auto restart at the setting battery voltage. |
Page 5 – Low Battery Shutdown Voltage![]() | 10.0/10.2/10.4/10.6/10.8/11.0VESC | 10.0V | The Power Inverter will shut off if the battery voltage is decreasing to the setting value. |
Page 6 – LCD Auto Sleep![]() | Off0.5/1/2 MinESC | 1 Min | If Auto Sleep is selected, the LCD display will shut off after 0.5/1/2 minutes if no activity. |
Page 7 – Cycling Display![]() | Off0.5/1 MinESC | 0.5 Min | If the buttons are not touched in 0.5/1 minute, the LCD will start cycling the Inverter information. |
Page 8 – Back to Default![]() | ESCYes | ESC | Select Yes to restore the factory default settings. |
Page 9 – Return to Status Display![]() | - | - | Press the Setup button to go back to the status display. |
5 TROUBLESHOOTING
| Problem | Possible Cause | Solution |
| The product will not turn on. | The unit is not connected to an AC wall outlet. | The unit must be connected to a 220/230V outlet. |
| The battery is worn out. | Replace the batteries. | |
| Mechanical problem. | Contact CyberPower Systems. | |
| Outlet does not provide power to connected equipment. | Circuit breaker has tripped due to an overload. | Turn the unit off and remove some of the connected equipment. Wait 10 seconds, reset the circuit breaker by depressing the button, and then turn the unit on. |
| DC fuse is blown due to overload. | Servicing of the DC fuse should only be performed by trained personnel. For more information on DC fuse replacement, contact CyberPower Systems. | |
| Batteries are discharged. | Recharge the unit for at least 8 hours. | |
| The product may require service. | Contact CyberPower Systems. | |
| There is no LCD display. | The product is not turned on. | Press the power button. |
| Batteries are discharged. | Recharge the unit for at least 8 hours. | |
| The LCD is defective. | Contact CyberPower Systems. | |
| Utility power is normal but the unit is in Battery Mode. | AC input is missing. | Make sure the AC input is well-connected. |
| Input protector is tripped. | Reset the input protector. | |
| The audible alarm beeps continuously. | The unit is in Fault Mode. | Refer to Fault Code Table for further information. Contact CyberPower Systems. |
Fault Code Table
| Fault Code | Event | Audible Alarm |
| A64 | Overload | Rapid beeping every 1/2 second |
| E07 | Output Voltage High | Constant tone |
| E09 | Output Short | Constant tone |
| E14 | Overload Fault | Constant tone |
| E18 | Fan Fail | Constant tone |
| E13 | Over Charge | Constant tone |
| E25 | Output Voltage Unbalance | Constant tone |
6 TECHNICAL SPECIFICATIONS
| Model | CPD1200EILCD |
| Power Rating (VA/Watt) | 1200VA/900W |
| Input | |
| Input Voltage Range | Narrow Mode: 170 - 280VacWide Mode: 90 - 280Vac |
| Input Frequency | 50/60Hz (Auto-sensing) |
| Output | |
| Output Voltage | 230Vac |
| Output Frequency | 50/60Hz |
| Outlet Type | (1) UN |
| Transfer Time | < 8ms (Typical Narrow Mode) |
| Battery | |
| Battery Voltage | 12V |
| Charging Current | 10A / 15A / 20A (Adjustable) |
| Environmental | |
| Operating Temperature (°C) | 0°C to 40°C |
| Operating Relative Humidity | 0 to 90% (non-condensing) |
| Physical | |
| Dimensions (WxHxD) (mm.) | 266 x 92 x 273 |
| Weight (kg.) | 2.5 |
For more information, visit www.cyberpower.com
All rights reserved. Reproduction without permission is prohibited.