1 Introduction....2
2 Product Features....3
3 Getting Started ....4
3.1 Parts List 4
3.2 Recommend Tools....4
3.3 Thermo-Hygrometer Sensor Set Up....4
3.4 Display Console Set Up 5
3.4.1 Radio Controlled Clock (RCC)....6
3.4.2 Display Console Layout....6
3.4.3 Sensor Operation Verification 8
4 Remote Sensor Installation 8
4.1 Sensor Placement 8
4.2 Wireless Reception Considerations....8
5 Console Operation....9
5.1 Quick Display Mode 9
5.1.1 Quick Display Mode Quick Reference Guide....9
5.1.2 Quick Display Mode Operation 9
5.2 Set (Program) Mode 10
5.2.1 Set Mode Quick Reference Guide....10
5.2.2 Set Mode Operation 10
5.2.3 Setting Barometric Pressure....13
5.2.4 Setting Calibrated Humidity....14
5.2.5 Setting Calibrated Temperature....14
5.3 Alarm Mode 15
5.3.1 Alarm Display 15
5.3.2 Alarm Programming....15
5.3.3 Cancelling the Alarm....16
5.3.4 Outdoor Alarm - Temperature vs. Dew Point 16
5.4 Min/Max Mode 16
5.5 Other Console Features....17
5.5.1 Weather Forecasting....17
5.5.2 Weather Forecast Initialization....17
5.5.3 Weather Icons....18
5.5.4 Weather tendency indicator....18
5.5.5 Storm threshold indicator....18
5.5.6 Pressure threshold setting....19
5.5.7 Pressure Graph....19
5.5.8 Moon Phase....19
5.5.9 Sunrise and Sunset 19
5.5.10 Restoring Lost Outdoor Temperature and Humidity Sensor 20
5.5.11 Factory Reset 20
-
Glossary of Terms 21
-
Specifications 21
7.1 Wireless Specifications 21
7.2 Measurement Specifications 22
7.3 Power Consumption....22 - Troubleshooting Guide....22
- Accessories 24
- Product Revisions....24
- Liability Disclaimer....25
- FCC Statement....25
- Warranty Information 26
1 Introduction
Thank you for your purchase of the Ambient Weather WS-1173B Advanced Weather Station with Temperature, Humidity, Barometer, Advanced Forecasting, Sunrise, Sunset and Moonphase. The following user guide provides step by step instructions for installation, operation and troubleshooting. To download the latest manual and additional troubleshooting tips, please visit:
http://ambientweather.wikispaces.com/ws1173
2 Product Features

text_image
ambient weather sunrise moon phase sunset 7:30 PM 5:48 IN TEMP OUTTEMP 88.5°F HUMIDITY 100.4°F 45% RH HUMIDITY 56% RH PRESSURE NIAL abs inHg (N=3) 24 -21 -18 -15 -12 -9 -6 -3 -1 TIME SEC DATE 8:28 07 MON 05.25.15 SET ALM MIN/MAX + 1 2 3 4 5 6Figure 1
| No | Description | No | Description |
| 1 | Forecast Icons | 5 | Barometric Pressure |
| 2 | Moonphase | 6 | Radio Controlled Clock with Perpetual Calendar |
| 3 | Sunrise and Sunset | 7 | Indoor Humidity and Temperature |
| 4 | Outdoor Temperature and Humidity | ||

text_image
Temperature & Humidity Sensor 68° RH 230°Figure 2
3 Getting Started
Note: The power up sequence must be performed in the order shown in this section (remote transmitter first, Display Console second) to avoid the console synchronization time out.
The WS-1173B weather station consists of a display console (receiver), and a thermo-hygrometer (remote transmitter).
3.1 Parts List
| QTY | Item |
| 1 | Display ConsoleFrame Dimensions (LxWxH): 7.25 x 4 x 1.25 inLCD Dimensions (LxW): 4.25 x 2.50” |
| 1 | Thermo-hygrometer transmitter (WH2B) with mounting bracketDimensions (LxWxH): 3.5” x 2.5” x 0.9” |
3.2 Recommend Tools
• Philips precision screwdriver
- Drill for mounting bracket
3.3 Thermo-Hygrometer Sensor Set Up
Note: To avoid permanent damage, please take note of the battery polarity before inserting the batteries.
Remove the battery door on the back of the sensor with a Philips screwdriver (there is only one screw, at the bottom of the unit). Insert two AAA batteries as shown in Figure 3.
We recommend lithium batteries for cold weather climates, but alkaline batteries are sufficient for
most climates. We do not recommend rechargeable batteries. They have lower voltages, do not operate well at wide temperature ranges, and do not last as long, resulting in poorer reception.
Replace the battery door and set screw. Note that the temperature and humidity will be displayed on the LCD display. Looking at the back of the unit from left to right, the polarity is (-) (+) for the top battery and (+) (-) for the bottom battery.

natural_image
Close-up of a white electronic device rear panel showing two battery cells with polarity markings (no text or symbols visible)Figure 3
3.4 Display Console Set Up
Note: To avoid permanent damage, please take note of the battery polarity before inserting the batteries.
Place the remote thermo-hygrometer about 5 to 10^ away from the display console (if the sensor is too close, it may not be received by the display console).
Remove the battery door on the back of the display. Insert three AA (alkaline or lithium, avoid rechargeable) batteries in the back of the display console. Looking at the back of the unit (left to right), the polarity is (+) (-) for the top battery, (-) (+) for the middle battery and (+) (-) for the bottom battery.
The display will beep once and all of the LCD segments will light up for a few seconds to verify all segments are operating properly.
Replace the battery door, and fold out the desk stand and place the console in the upright position.
The console will instantly display indoor temperature, humidity, barometer, tendency, date and time.
The remote search icon 📋 will turn on and should remain on for several minutes.
The outdoor temperature and humidity will update on the display within a few minutes.
Do not touch any buttons until the remote sensor reports in, otherwise the remote sensor search mode will be terminated and the search icon will turn off. When the remote sensor data has been received, the console will automatically switch to the normal mode, and all further settings can be performed.
If the remote does not update, please reference the troubleshooting guide in Section 8.
3.4.1 Radio Controlled Clock (RCC)
If your console is equipped with the Radio Controlled Clock (RCC), the icon WWVB will appear above the time. WWVB is the NIST time signal radio station near Fort Collins, Colorado.
The RCC is received by the wireless transmitter, and passed to the console. After the remote sensor is powered up, the sensor will transmit weather data for 30 seconds, and then the sensor will begin radio controlled clock (RCC) reception. The sensor search icon will remain on:
During the RCC time reception period (maximum 10 minutes), no weather data will be transmitted to avoid interference.
If the signal reception is not successful (normally during the day due to solar interference), the sensor search will be cancelled, the outdoor temperature and humidity will update as normal, and the RCC search will automatically resume every two hours until the signal is successfully captured. The regular RF link will resume once RCC reception routine is finished. In some locations, RCC reception may take a couple of days to receive the signal. The temperature and humidity data will continue to transmit during this period.
Once the radio controlled time is RCC reception icon ▲ will turn on (reference Figure 5).
3.4.2 Display Console Layout
Note: The following illustration shows the full segments of the LCD for description purposes only and will not appear like this during normal operation.

text_image
1 2 3 4 5 sunrise moon phase sunset 6 PM 88:88 PM 88:88 IN TEMP HAL LOAL 11 10 11 12 PRESSURE abs rel 188.8.8 hPa InHg 20 21 22 TIME DST DCF WWVB SEC DATE COUNTRY CITY 30 31 32 33 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90Figure 4
- Weather forecast icon
- low battery indicator
- MIN/MAX information
- Sunrise time
- Moon phase indicator
- Sunset time
- Indoor temperature low / high alarm
- Indoor temperature display
- Temperature display unit
- Indoor humidity display
- Indoor temperature and humidity alarm on indicator
- Indoor humidity low / high alarm
- Dew point temperature display
- Outdoor temperature low/high alarm
- Outdoor t temperature and humidity alarm on indicator
- Temperature display unit
-
Outdoor temperature display
-
Outdoor humidity display
- Outdoor humidity low/high alarm
- Absolute or relative air pressure selection
- Barometer air pressure
- Pressure with 24 hour history graph
- Pressure high alarm
- Pressure alarm on indicator
- Pressure low alarm
- Pressure display unit (inHg or hPa)
- DST (daylight savings time), WWVB indicator (radio controlled or atomic time received from Colorado), or DCF (Europe only)
- Radio Controlled Time icon (flashes when updated)
- Time
- Second
- Day of week/ time zone
- Alarm on indicator
- Date (M / D / Y)
3.4.3 Sensor Operation Verification
Verify the indoor and outdoor humidity match closely with the console and sensor array in the same location (about 10' apart). The sensors should be within 10% (the accuracy is ± 5%). Allow about 30 minutes for both sensors to stabilize.
Verify the indoor and outdoor temperature match closely with the console and sensor array in the same location (about 10' apart). The sensors should be within 4°F (the accuracy is ±2°F). Allow about 30 minutes for both sensors to stabilize.
4 Remote Sensor Installation
4.1 Sensor Placement
It is recommended you mount the remote sensor outside on a north facing wall, in a shaded area, at a height at or above the receiver. If a north facing wall is not possible, choose a shaded area, under an eve.
Direct sunlight and radiant heat sources will result in inaccurate temperature readings. Although the sensor is weatherproof, it is best to mount in a well-protected area, such as an eve.
Use 3 screws (included) to affix the mounting bracket to the wall with a precision screwdriver. Connect the remote sensor to the wall bracket. It is recommended to drill pilot holes first.

text_image
Remote Sensor Wall BracketFigure 5
Note: Make sure the sensor is mounted vertically and not lying down on a flat surface. This will insure optimum reception.
4.2 Wireless Reception Considerations
Wireless signals are impacted by distance, interference (other weather stations, wireless phones, wireless routers, TVs and computer monitors), and transmission barriers, such as walls. In general, wireless signals will not penetrate solid metal and earth (down a hill, for example).
The following is a table of reception loss vs. the transmission medium. Each “wall” or obstruction decreases the transmission range by the factor shown below.
| Medium | RF Signal Strength Reduction |
| Glass (untreated) | 5-15% |
| Plastics | 10-15% |
| Wood | 10-40% |
| Brick | 10-40% |
| Concrete | 40-80% |
| Metal | 90-100% |
5 Console Operation
Note: The console has four keys for easy operation: SET key, ALARM key, MIN/MAX key and +key. There are four program modes: Quick Display Mode, Set Mode, Alarm Mode and Min/Max Mode.
Any program mode can be exited at any time by either pressing the SNOOZE/LIGHT key (on the top of the display console), or waiting for the 10-second time-out to take effect.
5.1 Quick Display Mode
5.1.1 Quick Display Mode Quick Reference Guide
| Command | Mode | Settings |
| [SET] | Enter Quick Set Mode, Outdoor Temperature vs Dew Point | Press [+] to toggle between outdoor temperature and dew point. |
| [SET] | Relative Pressure vs Absolute Pressure | Press [+] to toggle between relative pressure and absolute pressure. |
5.1.2 Quick Display Mode Operation
While in Normal Mode, press the SET key to enter the Quick Display Mode as follows (once for outdoor temperature and dew point and twice for absolute pressure and relative pressure):
-
Display Outdoor Temperature and Dew Point. Press the MIN/MAX or ☐ key to toggle between outdoor temperature and dew point.
-
Absolute Pressure and Relative Pressure. Press the MIN/MAX or +key to toggle between absolute pressure and relative pressure.
5.2 Set (Program) Mode
5.2.1 Set Mode Quick Reference Guide
| Command | Mode | Settings |
| [SET] + 3 seconds | Enter Set Mode, Daylight Savings Time (DST) | Press [+] to toggle OFF and ON |
| [SET] | Time Zone (TZ) | Press [+] to increase. [MIN/MAX] to decrease |
| [SET] | 12/24 Hour Format | Press [+] to toggle between 12 hour (12h) and 24 hour (24h) format |
| [SET] | Latitude Location Hemisphere (LA) | Press [+] to toggle between Northern (Nth) and Southern hemisphere (Sth) |
| [ALARM] | Latitude (whole number) | Press [+] to increase. [MIN/MAX] to decrease |
| [ALARM] | Latitude (decimal number) | Press [+] to increase. [MIN/MAX] to decrease |
| [SET] | Longitude Location Hemisphere (LO) | Press [+] to toggle between Western (WST) and Eastern (EST) hemisphere |
| [ALARM] | Longitude (whole number x 100) | Press [+] to toggle between 1 and 0 |
| [ALARM] | Longitude (whole number) | Press [+] to increase. [MIN/MAX] to decrease |
| [ALARM] | Longitude (decimal number) | Press [+] to increase. [MIN/MAX] to decrease |
| [SET] | Hour of Day | Press [+] to increase. [MIN/MAX] to decrease |
| [SET] | Minute of Day | Press [+] to increase. [MIN/MAX] to decrease |
| [SET] | Year | Press [+] to increase. [MIN/MAX] to decrease |
| [SET] | Month of Year | Press [+] to increase. [MIN/MAX] to decrease |
| [SET] | Day of Month | Press [+] to increase. [MIN/MAX] to decrease |
| [SET] | Temperature Units of Measure | Press [+] to toggle between degF and degC |
| [SET] | Indoor Temperature Calibration | Press [+] to increase. [MIN/MAX] to decrease |
| [SET] | Indoor Humidity Calibration | Press [+] to increase. [MIN/MAX] to decrease |
| [SET] | Outdoor Temperature Calibration | Press [+] to increase. [MIN/MAX] to decrease |
| [SET] | Outdoor Humidity Calibration | Press [+] to increase. [MIN/MAX] to decrease |
| [SET] | Barometric Pressure Units of Measure | Press [+] to toggle between inHg and hPa |
| [SET] | Relative Pressure Calibration | Press [+] to increase. [MIN/MAX] to decrease |
| [SET] | Pressure Threshold for Forecast | Press [+] to increase. [MIN/MAX] to decrease |
| [SET] | Storm Threshold for Forecast | Press [+] to increase. [MIN/MAX] to decrease |
| [SET] | Exit Set Mode |
5.2.2 Set Mode Operation
While in Normal Mode, press and hold the SET key for at least three seconds (until it beeps) to enter the Set Mode. The first setting will begin flashing. You can press the SET key again to advance to the next step, as defined below.

Note: In the Set mode, press the + key or MIN/MAX key to change or scroll the value. Hold + key or MIN/MAX key for 3 seconds to increase/decrease rapidly.

Note: Press the SNOOZE key (or wait 30 seconds for timeout), and the Set Mode will return to mal Mode.
- Daylight Savings Time (DST). The DST (ON or OFF) setting will begin flashing. Press the + key to toggle between DST ON and DST OFF.
Note: The DST should always be ON unless you live in Arizona or Hawaii, which do not observe DST. If you turn this feature ON, it will automatically adjust time after daylight savings and standard time changes. ^1
- Time Zone Settings. Press the SET key again to adjust the Time Zone (TZ) setting.
Press the + key or MIN/MAX key to adjust the time zone from -12 to 12, based on the number of hours from Coordinated Universal Time, or Greenwich Mean Time (GMT).
The following table provides times zones throughout the world. Locations in the eastern hemisphere are positive, and locations in the western hemisphere are negative.
| Hours from GMT | Time Zone | Cities |
| -12 | IDLW: International Date Line West | --- |
| -11 | NT: Nome | Nome, AK |
| -10 | AHST: Alaska-Hawaii StandardCAT: Central AlaskaHST: Hawaii Standard | Honolulu, HI |
| -9 | YST: Yukon Standard | Yukon Territory |
| -8 | PST: Pacific Standard | Los Angeles, CA, USA |
| -7 | MST: Mountain Standard | Denver, CO, USA |
| -6 | CST: Central Standard | Chicago, IL, USA |
| -5 | EST: Eastern Standard | New York, NY, USA |
| -4 | AST: Atlantic Standard | Caracas |
| -3 | --- | São Paulo, Brazil |
| -2 | AT: Azores | Azores, Cape Verde Islands |
| -1 | WAT: West Africa | --- |
| 0 | GMT: Greenwich MeanWET: Western European | London, England |
| 1 | CET: Central European | Paris, France |
| 2 | EET: Eastern European | Athens, Greece |
| 3 | BT: Baghdad | Moscow, Russia |
| 4 | --- | Abu Dhabi, UAE |
| 5 | --- | Tashkent |
| 6 | --- | Astana |
| 7 | --- | Bangkok |
| 8 | CCT: China Coast | Beijing |
| 9 | JST: Japan Standard | Tokyo |
| 10 | GST: Guam Standard | Sydney |
| 11 | --- | Magadan |
| 12 | IDLE: International Date Line EastNZST: New Zealand Standard | Wellington, New Zealand |
-
12/24 Hour Format. Press the SET key again to adjust the 12/24 hour format setting. Press the + key to change between 12 hour and 24 hour format.
-
Latitude Location. Press the SET key again to adjust the Northern and Southern Hemisphere settings. The icon LA (latitude) will appear in the Time and Date field. Press the +key to change between NTH (northern hemisphere) and STH (southern hemisphere).
Next, press the ALARM key to adjust the latitude whole number. Press the + key or MIN/MAX key to adjust the latitude whole number up or down.
Press the ALARM key again to adjust the latitude decimal number. Press the + key or MIN/MAX key to adjust the latitude decimal number up or down.
Note: North America is located in the northern hemisphere. Therefore, there is no need to change this setting for the United States and Canada.
Note: To determine your latitude and longitude, we recommend visiting:
http://www.bing.com/maps/
and enter your street address. For more detailed information on determining and entering longitude and latitude, reference section 5.5.9.
- Longitude Location. Press the SET key again to adjust the Eastern and Western Hemisphere settings. The icon LO (longitude) will appear in the Time and Date field. Press the +key to change between EST (eastern hemisphere) and WST (western hemisphere).
Next, press the ALARM key to adjust the longitude whole number x 100. Press the +key or MIN/MAX key to adjust the longitude whole number x 100 up or down.
Press the ALARM key again to adjust the longitude decimal number. Press the + key or MIN/MAX key to adjust the longitude decimal number up or down.
Note: North America is located in the western hemisphere. Therefore, there is no need to change this setting for the United States and Canada.
-
Change Hour. Press the SET key again to set the hour. Press the +key or MIN/MAX key to adjust the hour up or down.
-
Change Minute. Press the SET key again to set the minute. Press the +key or MIN/MAX key to adjust the minute.
-
Change Year: Press the SET key again to set the calendar year. Press the ☐ key or MIN/MAX key to adjust the calendar year.
-
Change Month. Press the SET key again to set the calendar month. Press the + key or MIN/MAX key to adjust the calendar month.
-
Change Day. Press the SET key again to set the calendar day. Press the + key or MIN/MAX key to adjust the calendar day (note that the display format is Month/Day/Year).
-
Temperature Units (Celsius or Fahrenheit). Press the SET key again to toggle the temperature units from Celsius to Fahrenheit.
-
Indoor Temperature Calibration (default is measured indoor temperature). Press the SET key to adjust the indoor temperature. Press the ☐ key or MIN/MAX key to adjust the temperature up or down in 0.1 degC (0.18 degF) increments.
To view the uncalibrated value, press the ALARM key while the temperature is flashing.
Reference Section 5.2.5 Setting Calibrated Temperature for more details on this function.
- Indoor Humidity Calibration (default is measured indoor humidity). Press the SET key to adjust the indoor humidity. Press the ☐ key or MIN/MAX key to adjust the humidity up or down in 1% increments.
Reference Section 5.2.4 Setting Calibrated Humidity for more details on this feature.
- Outdoor Temperature Calibration (default is measured outdoor temperature). Press the SET key to adjust the outdoor temperature. Press the + key or MIN/MAX key to adjust the temperature up or down in 0.1 degC (0.18 degF) increments.
To view the uncalibrated value, press the ALARM key while the temperature is flashing.
Reference Section 5.2.5 Setting Calibrated Temperature for more details on this feature.
- Outdoor Humidity Calibration (default is measured outdoor humidity). Press the SET key to adjust the outdoor humidity. Press the + key or MIN/MAX key to adjust the humidity up or down in 1% increments.
To view the uncalibrated value, press the ALARM key while the humidity is flashing.
Reference Section 5.2.4 Setting Calibrated Humidity for more details on this feature.
-
Barometric Pressure Display Units (hPa or inHg). Press the SET key again to toggle the pressure units between hPa or inHg.
-
Relative Pressure Calibration (default is 29.92 inHg). Press the SET key to adjust the relative barometric pressure. Press the + key or MIN/MAX key to adjust the relative barometric pressure up or down. Reference Section 5.2.3 Setting Barometric Pressure for more details on this function.
-
Pressure Threshold Setting (default level 2). Press the SET key again to adjust the pressure threshold setting. Press the + key or MIN/MAX key to adjust the pressure threshold up or down. Reference Section 5.5.5 for more details on this function.
-
Storm Threshold Setting (default level 4). Press the SET key again to adjust the storm threshold setting. Press the + key or MIN/MAX key to adjust the storm threshold up or down. Reference 5.5.5 for more details on this function.
5.2.3 Setting Barometric Pressure
Note: This is a continuation of the previous section. To enter this mode, you must start at the beginning of this section.
The display console displays two different pressures: absolute (measured) and relative (corrected to sea-level).
To compare pressure conditions from one location to another, meteorologists correct pressure to
sea-level conditions. Because the air pressure decreases as you rise in altitude, the sea-level corrected pressure (the pressure your location would be at if located at sea-level) is generally higher than your measured pressure.
Thus, your absolute pressure may read 28.62 inHg (969 mb) at an altitude of 1000 feet (305 m), but the relative pressure is 30.00 inHg (1016 mb).
The standard sea-level pressure is 29.92 in Hg (1013 mb). This is the average sea-level pressure around the world. Relative pressure measurements greater than 29.92 in Hg (1013 mb) are considered high pressure and relative pressure measurements less than 29.92 in Hg are considered low pressure.
To determine the relative pressure for your location, locate an official reporting station near you (the internet is the best source for real time barometer conditions, such as Weather.com or Wunderground.com), and set your weather station to match the official reporting station.
To change the relative pressure in the SET mode, press the + key or MIN/MAX key to increase or decrease the relative pressure setting to match the official reporting station.
5.2.4 Setting Calibrated Humidity
Note: This is a continuation of the previous section. To enter this mode, you must start at the beginning of this section.
The display console allows you to calibrate both the indoor and outdoor humidity. Humidity is a difficult parameter to measure accurately and drifts over time. The calibration feature allows you to zero out this error. To calibrate humidity, you will need an accurate source, such as a sling psychrometer or Humidipaks One Step Calibration kit, available from Ambient Weather, which uses a salt bath.
To calibrate indoor humidity, in the Set Mode with indoor humidity flashing, press the +key or MIN/MAX key to increase or decrease the humidity setting (in increments of 1%) to match the calibrated or known humidity source. To return the indoor humidity to the measured value, press and hold the SET key for 3 seconds and the humidity will return to the uncalibrated value.
Note: The remote (outdoor) thermo-hygrometer will always display the measured humidity level and not the calibrated humidity level. Only the console will show the calibrated value.
Note: The dew point calculation is based on the calibrated humidity level.
5.2.5 Setting Calibrated Temperature
Temperature is measured by a resistive thermal device (RTD) and is subject to electronic variation.
Temperature errors can also occur when a sensor is placed too close to a heat source (such as a building structure, the ground or trees).
To calibrate the indoor or outdoor temperature, we recommend a mercury or red spirit (fluid) thermometer. Bi-metal (dial) and other digital thermometers are not a good source and have their own margin of error. Using a local weather station in your area is also a poor source due to changes in location, timing (airport weather stations are only updated once per hour) and possible calibration errors (many official weather stations are not properly installed and calibrated).
Place the sensor in a shaded, controlled environment next to the fluid thermometer, and allow the sensor to stabilize for 24 hours. Compare this temperature to the fluid thermometer and adjust the console to match the fluid thermometer.
To calibrate indoor or outdoor temperature, in the Set Mode with indoor or outdoor temperature flashing, press the + key or MIN/MAX key to increase or decrease the temperature setting (in increments of 0.1 degC or 0.18 degF) to match the calibrated or known temperature source.

Note: The remote (outdoor) thermo-hygrometer will always display the measured temperature
level and not the calibrated temperature level. Only the console will show the calibrated value.

Note: The dew point calculation is based on the calibrated temperature level.
5.3 Alarm Mode
5.3.1 Alarm Display
While in Normal Mode, press the ALARM key to enter the High Alarm Mode. Press the ALARM key again to enter the Low Alarm Mode. Press the ALARM key again to return to normal mode (or wait 30 seconds for the programming mode to timeout).

Note: After entering the ALARM mode, the console will display the high and low alarm
settings. If the value reads --.-- (dashes), the alarm is not active.
5.3.2 Alarm Programming
While in Alarm Mode, press the SET key to set the alarms. The following are high and low alarms:
High Alarm Limits:
• Time alarm (hour/minute)
- Indoor humidity high alarm
- Indoor temperature high alarm
• Outdoor humidity high alarm
• Outdoor temperature / dew point high alarm
- Pressure high alarm
Low Alarm Limits:
• In the Low Alarm Mode press the SET key to select the following alarm modes:
• Time alarm (hour/minute)
- Indoor humidity low alarm
- Indoor temperature low alarm
• Outdoor humidity low alarm
• Outdoor temperature / dew point low alarm
- Pressure low alarm
In the alarm mode, Press the + key or MIN/MAX key to change or scroll the alarm value.
Hold the + key or MIN/MAX key for 3 seconds to change the number rapidly. Press the ALARM key to select the alarm on or off (if alarm is enabled, the speaker icon on the LCD will be turned on
indicating the alarm function has been enabled).
Press the SET key to confirm the setting and continue pressing the SET key to toggle through each alarm mode until it returns to the normal display mode.
Press the SNOOZE key or wait 30 seconds for the programming mode to timeout, and the alarm mode will return to the normal mode.
5.3.3 Cancelling the Alarm
When an alarm condition has been activated, the specific alarm will sound and flash for 120 seconds. Press any key to cancel the alarm.
When an alarm condition is activated again within 10 minutes, the alarm will not sound but will continue to flash until the weather condition is stable. This feature is useful to avoid repeated triggering for the same alarm value.
The alarm will reset automatically once the value has fallen below the set value, or if a new value is entered.
5.3.4 Outdoor Alarm - Temperature vs. Dew Point
When the outdoor weather alarm has been triggered, it will flash on the LCD display and the general outdoor alarm icon and high/low alarm icon will flash. For example, in the outdoor temperature display mode, when dew point high alarm is triggered the DEW POINT icon will flash along with general outdoor alarm icon and high alarm icon, indicating that the current alarm source is from dew point.
Temperature display mode

text_image
OUT HI AL 60% RH TEMP 30.2 °C Dew point high alarm was triggered OUT HI AL 60% RH DEW POINT 30.2 °C digit flashing digit flashing digit flashingFigure 4
5.4 Min/Max Mode
Note: The min and max settings cannot be reset at the same time. They must be reset on an individual basis.
While in Normal Mode, press the MIN/MAX key to enter the maximum mode, and the MAX icon and maximum records will be displayed and begin flashing.
Press MIN/MAX key again to enter the minimum mode, and the MIN icon and minimum records will be displayed and begin flashing.
Press MIN/MAX key again to return the Normal Mode.
In the maximum (or minimum) reading Mode, press the + key to display the specific maximum (or minimum) value you wish to reset. This value will begin flashing with the time and date time stamp at which the maximum (or minimum) value occurred. Select the + key again to proceed to the next parameter, in the following order:
- Indoor humidity maximum (or minimum)
- Indoor temperature maximum (or minimum)
- Outdoor humidity maximum (or minimum)
- Outdoor temperature maximum (or minimum)
- Pressure maximum (or minimum)
Press the SET key for two seconds to reset the specific value (that is flashing) and associated date and time to the current reading.
Press the SNOOZE key or wait 30 seconds for the programming mode to timeout, and the Min/Max mode will return to Normal Mode.
5.5 Other Console Features
The following section describes additional console features.
5.5.1 Weather Forecasting
Note: The weather forecast or pressure tendency is based on the rate of change of barometric pressure. In general, when the pressure increases, the weather improves (sunny to partly cloudy) and when the pressure decreases, the weather degrades (cloudy to rain).
It may take several days to begin forecasting the weather. In the meantime, there may be no trend arrows and the both icons display partly cloudy.
The weather forecast is an estimation or generalization of weather changes in the next 24 to 48 hours, and varies from location to location. The tendency is simply a tool for projecting weather conditions and is never to be relied upon as an accurate method to predict the weather.
5.5.2 Weather Forecast Initialization
When the console is powered up, the forecast prediction is in the “learning mode”. Two partly cloudy icons will be displayed, as shown below. When there is a change in barometric pressure over 24 to 72 hours, the forecast icons will exit the learning mode.


5.5.3 Weather Icons

Sunny

Partly Cloudy

Cloudy

Rainy
The four weather icons are Sunny, Partly Cloudy, Cloudy and Rainy. There are also two weather tendency indicators to show the air pressure tendency between the weather icons.
5.5.4 Weather tendency indicator
The weather tendency arrow is located between the weather icons to show the air pressure tendency and provide a forecast based on increasing or decreasing air pressure.
The arrow pointing to the right indicates that the air pressure is increasing and the weather is expected to improve. The arrow pointing the left indicates that the air pressure is decreasing and the weather is expected to deteriorate.
The weather tendency is based on the pressure change since last six hours. If the weather is changing, the weather tendency indicator (animated arrows) will flash for three hours, indicating the weather is expected to change. If the weather conditions become stable and no new weather change conditions are met, then the arrows will be fixed.
Example 1: Pressure is decreasing, weather is deteriorating in 24-48 hours.

flowchart
graph LR
A["Cloud with raindrops"] <--> B["Cloud with cloud"]
Example 2: Pressure is increasing, weather is improving in 24-48 hours.

flowchart
graph LR
A["Cloud Icon"] --> B["Sun icon"]
5.5.5 Storm threshold indicator
The storm threshold (the negative rate of pressure change signifying a storm is expected) can be adjusted by the user from level 3 to level 9 (the default level 4 mbar/hour).
When negative rate of change of pressure is exceeded for 3 hours, the storm warning indicator will be activated, and the clouds with rain icon and tendency arrows will flash for 3 hours indicating the storm
warning feature has been activated.

natural_image
Simple weather icon showing cloud with raindrops and two arrows pointing left (no text or symbols)5.5.6 Pressure threshold setting
The pressure threshold (the negative or positive rate of change of pressure signifying a change in the weather) can be adjusted by the user from level 2 to level 4 (default level 2 mbar/hour).
The lower the level pressure threshold setting, the higher sensitivity for weather forecast changes. Locations that experience frequent changes in air pressure require a higher setting compared to locations where the air pressure is typically stagnant.
5.5.7 Pressure Graph
The pressure graph displays the barometric pressure for the last 24 hours. Each bar represents three hours. The vertical scale of the graph is auto-scaled. There is not fixed pressure level for each bar, and is intended for visualizing trends only.
5.5.8 Moon Phase
The following moon phases are displayed based on the calendar date.
| New | Waxing Crescent | First Quarter | Waxing Gibbous | Full | Waning Gibbous | Third Quarter | Waning | New |
5.5.9 Sunrise and Sunset
To determine your longitude and latitude, we recommend the following website:
www.bing.com/maps
Reference Figure 6 below:
- Enter your address and select the search button
- The latitude (first number) and longitude (second number) are returned. In this example:
Latitude = 33.2981181889772
Longitude = -111.960209459066
The table below defines the hemisphere based on the positive or negative sign:
| Position | Positive | Negative |
| Latitude | Northern | Southern |
| Longitude | Eastern | Western |
- In this example, the location entered into the display is as follows:
Latitude = 33.30 North
Longitude = 111.96 West
after rounding to two significant digits.
text_image
6845 W. Frye Road, Chandler, AZ 85226 Maps Web Maps Directions My places Map apps Road Bird's eye Traffic 6845 W Frye Rd, Chandler, AZ 85226 33.2981181889772 -111.960209459066 © Microsoft CorporationFigure 6
5.5.10 Restoring Lost Outdoor Temperature and Humidity Sensor
If the signal is lost between the remote sensor (or transmitter) and the display console (or the receiver), to resynchronize, while in normal mode, press and hold the + key for 10 seconds. The transmitter search icon will appear.
Please wait several minutes for the search icon to turn off and the remote sensor reports in. Do not touch any buttons until synchronization is complete.
If the synchronization fails, reset the console by removing one battery from the display console, wait 10 seconds, and reinsert the battery, as specified in Section 3.4 Display Console Set Up.
5.5.11 Factory Reset
If memory is corrupted, you may need to restore the console to factory default.
To restore the console to factory reset and resync the remote sensor to the console:
-
Remove one battery from the battery compartment. Wait 10 seconds for the console to go completely blank.
-
Press and hold the [SET] and [MIN/MAX] buttons at the same time and reinsert the battery.
Continue to hold. The backlight will flash 12 times.
- When the flashing is complete, let go of the buttons. The console has now been restored to factory default.
-
Wait several minutes before pressing any buttons for the remote sensor to sync to the console.
-
With the remote and console 10 feet away from each other, remove the batteries from the display console and wait 10 seconds. Put the batteries back in.
-
Do not touch any buttons for several minutes.
-
The remote sensor search icon will appear near where the outdoor temperature and humidity would normally be. Wait several minutes for this icon to turn off.
6. Glossary of Terms
| Term | Definition |
| Absolute Barometric Pressure | Relative barometric pressure, corrected to sea-level. To compare pressure conditions from one location to another, meteorologists correct pressure to sea-level conditions. Because the air pressure decreases as you rise in altitude, the sea-level corrected pressure (the pressure your location would be at if located at sea-level) is generally higher than your measured pressure. |
| Accuracy | Accuracy is defined as the ability of a measurement to match the actual value of the quantity being measured. |
| HectoPascals (hPa) | Pressure units in SI (international system) units of measurement. Same as millibars (1 hPa = 1 mbar) |
| Hygrometer | A hygrometer is a device that measures relative humidity. Relative humidity is a term used to describe the amount or percentage of water vapor that exists in air. |
| Inches of Mercury (inHg) | Pressure in Imperial units of measure. 1 inch of mercury = 33.86 millibars |
| Range | Range is defined as the amount or extent a value can be measured. |
| Relative Barometric Pressure | Measured barometric pressure relative to your location or ambient conditions. |
7. Specifications
7.1 Wireless Specifications
• Line of sight wireless transmission (in open air): 300 feet
• Frequency: 433 MHz
- Update Rate: 48 seconds
7.2 Measurement Specifications
The following table provides specifications for the measured parameters.
| Measurement | Range | Accuracy | Resolution |
| Indoor Temperature | 32 to 140 °F | ±2 °F | 0.1 °F |
| Outdoor Temperature | -40 to 149 °F | ±2 °F | 0.1 °F |
| Indoor Humidity | 1 to 99 % | ±5% (only guaranteed between 20 to 90%) | 1 % |
| Outdoor Humidity | 1 to 99% | ±5% (only guaranteed between 20 to 90%) | 1 % |
| Barometric Pressure | 8.85 to 32.50 inHg | ±0.08 inHg (within range of 27.13 to 32.50 inHg) | 0.01 inHg |
7.3 Power Consumption
- Base station : 3 x AA 1.5V Alkaline batteries
• Remote sensor : 2 x AAA 1.5V Alkaline batteries
• Battery life: Minimum 12 months for base station
Minimum 24 months for thermometer-hygrometer sensor (use lithium batteries in cold weather climates)
8. Troubleshooting Guide
If your question is not answered here, you can contact us as follows:
- Email Support: support@ambientweather.com
- Technical Support: 480-346-3380 (M-F 8am to 3pm Arizona Time)
| Problem | Solution |
| Wireless remote (thermo-hygrometer) not reporting in to console.There are dashes (--) on the display console. | 1. Resync the unit. Press and hold the + key for 10 seconds to resynchronize. The remote sensor search icon will turn on. Wait several minutes for the remote sensor to report in, or the search icon to turn off.If the synchronization fails, reset the console by removing one battery from the display console, wait 10 seconds, and reinsert the battery.Do not press any buttons while in the search mode.2. Check the remote sensor is powered up and displaying the temperature and humidity on the LCD display.3. Install a fresh set of batteries in the remote thermo-hygrometer. For cold weather environments, install lithium batteries.4. The maximum line of sight communication range is 300'. Move the sensor assembly closer to the display console.5. If the sensor assembly is too close (less than 5-10'), move the sensor assembly away from the display console.6. Make sure the remote sensors are not transmitting through solid metal (acts as an RF shield), or earth barrier (down a hill).7. Move the display console around electrical noise generating devices, such as computers, TVs and other wireless transmitters or receivers.8. Move the remote sensor to a higher location.Move the remote sensor to a closer location.9. Radio Frequency (RF) Sensors cannot transmit through metal barriers (example, aluminum siding) or multiple, thick walls. |
| Temperature sensor reads too high in the day time. | Make sure the thermo-hygrometer is mounted in a shaded area on the north facing wall. |
| Indoor and Outdoor Temperature do not agree | 1. Allow up to one hour for the sensors to stabilize due to signal filtering. The indoor and outdoor temperature sensors should agree within 4 °F (the sensor accuracy is ±2 °F).2. Perform a temperature calibration (reference Section 5.2.5) |
| Indoor and Outdoor Humidity do not agree | 1. Allow up to one hour for the sensors to stabilize due to signal filtering. The indoor and outdoor humidity sensors should agree within 10 % (the sensor accuracy is ±5 %)2. Perform a humidity calibration (reference Section 5.2.4) |
| Console outdoor humidity and remote humidity do not agree. | The console displays the calibrated humidity. The remote displays the measured humidity only. Refer to 5.2.4 to set and reset the humidity calibration. |
| Relative pressure does not agree with official reporting station | 1. You may be viewing the relative pressure, not the absolute pressure.2. Make sure you properly calibrate the barometer to an official local weather station (reference Section 4.2.1)3. The barometer is only accurate to ±0.08 inHg within the following relative pressure range: 27.13 to 32.50 inHg, which corresponds to an altitude of -2,200 to 2,700 feet. At higher altitudes, expect some non-linearity or error. |
| The forecast icon is not accurate | The weather station console must run for several days to trend barometric pressure.The weather forecast is an estimation or generalization of weather changes in the next 24 to 48 hours, and varies from location to location. The tendency is simply a tool for projecting weather conditions and is never to be relied upon as an accurate method to predict the weather. |
| Moon phase is not correct | Check your calendar date and make sure it is correct |
| Sunrise and Sunset is not correct | Check your longitude and latitude. The most common issues are:1. The longitude and latitude are reversed2. The incorrect hemisphere is selected3. The incorrect time zone is selected.4. The date is incorrect. |
| Sunrise and Sunset are off by one hour. | When you first set up the console, the atomic radio controlled time (WWVB) may not update immediately due to solar interference and other factors (since the signal is generated in Boulder, CO and bounces off the ionosphere).If you entered the time zone and daylight savings time (DST) properly, it is waiting for the RCC to update the DST flag.Once the DST updates, the WWVB icon will appear on the display and the sunrise and sunset are corrected.Wait for the radio controlled clock (RCC) time signal to update the clock, correcting for the hour offset generated by the daylight savings time.This can take a few days to update.As a temporary work around, to offset the hour normally accounted for by DST, add one hour to your time zone setting. For example, if you live in the Eastern Time Zone, the time zone setting is -5. Change to -4 and manually correct this time. This will correct your sunrise and sunset. You will need to perform this operation twice per year (each time DST changes). |
| Display console contrast is weak | Replace console batteries with a fresh set of batteries. |
| Console beeps and resets | Replace console batteries with a fresh set of batteries. |
9. Accessories
The following software and hardware accessories are available for this weather station at www.AmbientWeather.com.
| Accessory | Description |
| Energizer AA Lithium Battery (2-pack) - Batteries for Long Life and Cold Climates | AA lithium batteries for cold weather climates. |
| Ambient Weather SRS100LXTemperature and Humidity Solar Radiation Shield | Solar Radiation Shield improves temperature accuracy for hot weather climates. Remove the rain guard and install over thermo-hygrometer. |
10. Product Revisions
| Revision | Description |
| WS-1170 | Initial Release |
| WS-1173 | Added humidity calibration |
| WS-1173A | Added temperature calibrationIncreased programming timeout from 10 seconds to 30 secondsChanged barograph from scrolling to non-scrolling.Added function to reacquire lost remote signal without powering down and up console. |
| WS-1173B | Moved RCC receiver from the console to the transmitter to improve RCC reception. |
11. Liability Disclaimer
Please help in the preservation of the environment and return used batteries to an authorized depot. The electrical and electronic wastes contain hazardous substances. Disposal of electronic waste in wild country and/or in unauthorized grounds strongly damages the environment.
Reading the “User manual” is highly recommended. The manufacturer and supplier cannot accept any responsibility for any incorrect readings and any consequences that occur should an inaccurate reading take place.
This product is designed for use in the home only as indication of weather conditions. This product is not to be used for medical purposes or for public information.
The specifications of this product may change without prior notice.
This product is not a toy. Keep out of the reach of children.
No part of this manual may be reproduced without written authorization of the manufacturer.
Ambient, LLC WILL NOT ASSUME LIABILITY FOR INCIDENTAL, CONSEQUENTIAL, PUNITIVE, OR OTHER SIMILAR DAMAGES ASSOCIATED WITH THE OPERATION OR MALFUNCTION OF THIS PRODUCT.
12. FCC Statement
Statement according to FCC part 15.19:
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation.
Statement according to FCC part 15.21:
Modifications not expressly approved by this company could void the user's authority to operate the equipment.
Statement according to FCC part 15.105:
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
13. Warranty Information
Ambient, LLC provides a 1-year limited warranty on this product against manufacturing defects in materials and workmanship.
This limited warranty begins on the original date of purchase, is valid only on products purchased and only to the original purchaser of this product. To receive warranty service, the purchaser must contact Ambient, LLC for problem determination and service procedures.
Warranty service can only be performed by a Ambient, LLC. The original dated bill of sale must be presented upon request as proof of purchase to Ambient, LLC.
Your Ambient, LLC warranty covers all defects in material and workmanship with the following specified exceptions: (1) damage caused by accident, unreasonable use or neglect (lack of reasonable and necessary maintenance); (2) damage resulting from failure to follow instructions contained in your owner's manual; (3) damage resulting from the performance of repairs or alterations by someone other than an authorized Ambient, LLC authorized service center; (4) units used for other than home use (5) applications and uses that this product was not intended (6) the products inability to receive a signal due to any source of interference or metal obstructions and (7) extreme acts of nature, such as lightning strikes or floods.
This warranty covers only actual defects within the product itself, and does not cover the cost of installation or removal from a fixed installation, normal set-up or adjustments, claims based on misrepresentation by the seller or performance variations resulting from installation-related circumstances.