The information in this user's manual has been carefully reviewed and is believed to be accurate. The manufacturer assumes no responsibility for any inaccuracies that may be contained in this document, and makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates. Please Note: For the most up-to-date version of this manual, please see our website at www.supermicro.com.
Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product described in this manual at any time and without notice. This product, including software and documentation, is the property of Supermicro and/or its licensors, and is supplied only under a license. Any use or reproduction of this product is not allowed, except as expressly permitted by the terms of said license.
IN NO EVENT WILL Super Micro Computer, Inc. BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, SUPER MICRO COMPUTER, INC. SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTWARE, OR DATA STORED OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Supermicro's total liability for all claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in industrial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the manufacturer's instruction manual, may cause harmful interference with radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case you will be required to correct the interference at your own expense.
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. "Perchlorate Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate".
WARNING: Handling of lead solder materials used in this product may expose you to lead, a chemical known to the State of California to cause birth defects and other reproductive harm.
The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nuclear facilities or systems, aircraft, aircraft devices, aircraft/emergency communication devices or other critical systems whose failure to perform be reasonably expected to result in significant injury or loss of life or catastrophic property damage. Accordingly, Supermicro disclaims any and all liability, and should buyer use or sell such products for use in such ultra-hazardous applications, it does so entirely at its own risk. Furthermore, buyer agrees to fully indemnify, defend and hold Supermicro harmless for and against any and all claims, demands, actions, litigation, and proceedings of any kind arising out of or related to such ultra-hazardous use or sale.
Manual Revision 1.0a
Release Date: July 12, 2021
Unless you request and receive written permission from Super Micro Computer, Inc., you may not copy any part of this document. Information in this document is subject to change without notice. Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.
Copyright © 2021 by Super Micro Computer, Inc.
All rights reserved.
Printed in the United States of America
Preface
About This Manual
This manual is written for system integrators, IT technicians and knowledgeable end users. It provides information for the installation and use of the X12SPM-TF/-LN4F/-LN6TF motherboard.
About This Motherboard
The X12SPM-TF/-LN4F/-LN6TF supports a 3rd generation Intel® Xeon Scalable Processor series (Socket P+ (LGA4189) with up to 40 cores and a thermal design power (TDP) of up to 270W. Built with the Intel PCH C621A chipset, the X12SPM-TF/-LN4F/-LN6TF supports 8-channel, 8-DIMM DDR4 ECC RDIMM/LRDIMM memory with speeds of up to 3200MHz, SATA 3.0 ports, a M.2 slot, and a Trusted Platform Module (TPM) header. The X12SPM-TF/-LN4F/-LN6TF is optimized for high-performance, high-end computing platforms that address the needs of next generation server applications. Please note that this motherboard is intended to be installed and serviced by professional technicians only. For processor/memory updates, please refer to our website at http://www.supermicro.com/products/.
Conventions Used in the Manual
Special attention should be given to the following symbols for proper installation and to prevent damage done to the components or injury to yourself:

Warning! Indicates important information given to prevent equipment/property damage or personal injury.

Warning! Indicates high voltage may be encountered while performing a procedure.

Important: Important information given to ensure proper system installation or to relay safety precautions.

Note: Additional Information given to differentiate various models or provides information for proper system setup.
Contacting Supermicro
Headquarters
Address: Super Micro Computer, Inc.
980 Rock Ave.
San Jose, CA 95131 U.S.A.
Tel: +1 (408) 503-8000
Fax: +1 (408) 503-8008
Email: marketing@supermicro.com (General Information)
support@supermicro.com (Technical Support)
Website: www.supermicro.com
Europe
Address: Super Micro Computer B.V.
's-Hertogenbosch, The Netherlands
Tel: +31 (0) 73-6400390
Fax: +31 (0) 73-6416525
Email: sales@supermicro.nl (General Information)
support@supermicro.nl (Technical Support)
rma@supermicro.nl (Customer Support)
Website: www.supermicro.nl
Asia-Pacific
Address: Super Micro Computer, Inc.
3F, No. 150, Jian 1st Rd.
Zhonghe Dist., New Taipei City 235
Taiwan (R.O.C)
Tel: +886-(2) 8226-3990
Fax: +886-(2) 8226-3992
Email: support@supermicro.com.tw
Website: www.supermicro.com.tw
Table of Contents
Chapter 1 Introduction
1.1 Checklist....8
Quick Reference 13
Quick Reference Table....14
Motherboard Features....16
1.2 Processor and Chipset Overview....20
1.3 Special Features ....20
Recovery from AC Power Loss....20
1.4 System Health Monitoring....21
Onboard Voltage Monitors 21
Fan Status Monitor with Firmware Control 21
Environmental Temperature Control 21
System Resource Alert....21
1.5 ACPI Features....21
1.6 Power Supply 22
1.7 Serial Port....22
Chapter 2 Installation
2.1 Static-Sensitive Devices....23
Precautions 23
Unpacking 23
2.2 Processor and Heatsink Installation....24
The 3rd generation Intel Xeon Scalable Processor Series....24
Overview of the Processor Carrier Assembly 25
Overview of the CPU Socket 25
Overview of the Processor Heatsink Module....26
Creating the 3rd generation Intel Xeon Scalable Processor Carrier Assembly....27
Assembling the Processor Heatsink Module 28
Preparing the CPU Socket for Installation....29
Installing the Processor Heatsink Module....30
Removing the Processor Heatsink Module....31
2.3 Motherboard Installation....32
Tools Needed ....32
Location of Mounting Holes 32
Installing the Motherboard....33
2.4 Memory Support and Installation ....34
Memory Support....34
General Guidelines for Optimizing Memory Performance ....35
DIMM Installation ....36
DIMM Removal 36
2.5 Rear I/O Ports ....37
2.6 Front Control Panel 42
2.7 Connectors 47
Power Connections 47
Headers....50
2.8 Jumper Settings ....58
How Jumpers Work....58
2.9 LED Indicators....62
Chapter 3 Troubleshooting
3.1 Troubleshooting Procedures ....65
Before Power On 65
No Power 65
System Boot Failure 66
Memory Errors ....66
Losing the System's Setup Configuration....66
When the System Becomes Unstable....67
3.2 Technical Support Procedures ....69
3.3 Frequently Asked Questions....70
3.4 Battery Removal and Installation 71
Battery Removal....71
Proper Battery Disposal....71
Battery Installation....71
3.5 Returning Merchandise for Service....72
Chapter 4 UEFI BIOS
4.1 Introduction....73
4.2 Main Setup....74
4.3 Advanced....76
4.4 Event Logs 112
4.5 IPMI 114
4.6 Security....117
4.7 Boot....122
4.8 Save & Exit....124
Appendix A Software Installation
A.1 Installing Software Programs ....127
A.2 SuperDoctor ^® 5....128
A.3 IPMI 129
Appendix B Standardized Warning Statements
Battery Handling....130
Product Disposal....131
Chapter 1
Introduction
Congratulations on purchasing your computer motherboard from an industry leader. Supermicro motherboards are designed to provide you with the highest standards in quality and performance.
In addition to the motherboard, several important parts that are included in the retail box are listed below. If anything listed is damaged or missing, please contact your retailer.
1.1 Checklist
| Main Parts List | ||
| Description Part Number Quantity | ||
| Supermicro Motherboard X12SPM-TF/-LN4F/-LN6TF 1 | ||
| I/O Shield MCP-260-00130-0N 1 | ||
| SATA Cables CBL-0044L 2 | ||
| Quick Reference Guide MNL-2271-QRG 1 | ||
Important Links
For your system to work properly, please follow the links below to download all necessary drivers/utilities and the user's manual for your server.
• Supermicro product manuals: http://www.supermicro.com/support/manuals/
- Product drivers and utilities: https://www.supermicro.com/wdl/driver/
- Product safety info: http://www.supermicro.com/about/policies/safety_information.cfm
- A secure data deletion tool designed to fully erase all data from storage devices can be found at our website: https://www.supermicro.com/about/policies/disclaimer.cfm?url=/wftp/utility/Lot9_Secure_Data_Deletion_Utility/
- If you have any questions, please contact our support team at: support@supermicro.com
This manual may be periodically updated without notice. Please check the Supermicro website for possible updates to the manual revision level.
Figure 1-1. X12SPM-LN4F Motherboard Image

text_image
XT25PM-LN4F SUPER WARNING! This cap MUST be powered by defining the computer To protect the socket pins, remove this cap only when installing a CPU. Put this cap back if you removed the CPU.
Note: All graphics shown in this manual were based upon the latest PCB revision available at the time of publication of the manual. The motherboard you received may or may not look exactly the same as the graphics shown in this manual.
Figure 1-1. X12SPM-LN6TF Motherboard Image

text_image
ASPEED X2SPM1 MGIE SUPER WARNING! This copy MUST be placed if returning the milliseconds. To press the socket pins, remove this copy only when installing a CPU. Put this copy back 7 you removed to CPU.
Note: All graphics shown in this manual were based upon the latest PCB revision available at the time of publication of the manual. The motherboard you received may or may not look exactly the same as the graphics shown in this manual.
Figure 1-1. X12SPM-TF Motherboard Image

text_image
ASPEED X12SPM-TF SUPER WARNING! This may not be powered if To protect the socket press, remove this cap only when installing a CPU. As this cap back? You removed the CPU.
Note: All graphics shown in this manual were based upon the latest PCB revision available at the time of publication of the manual. The motherboard you received may or may not look exactly the same as the graphics shown in this manual.
Figure 1-1. Motherboard Image

text_image
SUPER X12SPM-LN4F/-TF/LN6TF REV: 2.00 DESIGNED IN USA BAR CODE MAC CODE
Note: Components not documented are for internal testing only.
Quick Reference

text_image
COM1 JIPMB1 JNVI2C1 SLOT6 SLOT7 TPM/PORT80 JD1 LEDPWR JF1 SLOT4 M.2-H JBT1 USB4/5 USB2/3 JPME2 S-SGPIO1 JS1 JS2 JSD1 USB8/9 (3.0) JSD2 JL1 USB10 (3.0) S-SATA0 S-SATA1 JNVME0 JNVME1 LEDM1 UID-LED1 JUIDB1 BT1 LAN5/6 LAN3/4 LAN1/2 USB6/7 (3.0) USB0/1 IPMI_LAN VGA JLANLED1 JLANLED2 JPL1 JPTG1 JPI2C1 JSTBY1 FAN4 JPWR1 DIMMG1 DIMMH1 DIMME1 DIMMF1 DIMMB1 DIMMA1 DIMMD1 DIMMC1 JPH1 CPU JPV1 FAN2 FAN1 BAR CODE MAC CODE
Notes:
- See Chapter 2 for detailed information on jumpers, I/O ports, and JF1 front panel connections.
- " " indicates the location of Pin 1.
- Jumpers/LEDs not indicated are used for testing only.
- Use only the correct type of onboard CMOS battery as specified by the manufacturer. Do not install the onboard battery upside down to avoid possible explosion.
Quick Reference Table
Jumper Description Default Setting
| JBT1 CMOS Clear Open (Normal) |
| JPL1 LAN3/4/5/6 Enable/Disable Pins 1-2 (Enabled) |
| JPME2 ME Recovery Pins 1-2 (Normal) |
| JPTG1 LAN1/2 (10G Base-T) Enable/Disable Pins 1-2 (Enabled) |
LED Description Status
| LEDM1 BMC Heartbeat LED Blinking Green: BMC Normal | ||
| LEDPWR Power on LED | Solid Green: On | |
| UID-LED1 | Unit Identifier (UID) LED | Solid Blue: Unit Identified |
Connector Description
| BT1 | Onboard CMOS Battery |
| COM1 | COM Header |
| FAN1 ~ FAN4, FANA | CPU/System Fan Headers |
| IPMI_LAN | Dedicated IPMI LAN Port |
| JD1 | Speaker (Pins 1-4: Speaker) |
| JF1 | Front Control Panel Header |
| JIPMB1 | 4-pin External I^2C Header |
| JL1 | Chassis Intrusion Header |
| JLANLED1 | LAN LED Activity Connector for the Front Panel (for LN4F/LN6TF only) |
| JLANLED2 | LAN LED Activity Connector for the Front Panel (for LN6TF only) |
| JNV ^2C 1 | NVMe I^2C Header |
| JNVME0/1 | PCIe 4.0 x8 Slimline SAS Connectors |
| JPH1 | 4-pin Power Output for HDD use(To provide power from the motherboard to onboard HDD devices) |
| JPI^2C 1 Power System Management Bus (SMB) I | ^2C Header |
| JPV1 | 8-pin 12V CPU Power Connector; Or 12V DC Input Power Connector(without JPWR1 plugged) |
| JPWR1 | 24-pin ATX Power Connector |
| JRK1 | Intel RAID Key Header |
| JS1 | Intel PCH SATA 3.0 Ports (I-SATA0-3 with RAID 0, 1, 5, 10) |
| JS2 | Intel PCH SATA 3.0 Ports (I-SATA4-7 with RAID 0, 1, 5, 10) |
| JSD1, JSD2 | SATA DOM Power Connectors |
| JSTBY1 | Standby Power Header |
| JUIDB1 | Unit Identifier (UID) Switch |
| LAN1/2 | 10GbE LAN (RJ45) Ports (LAN1/LAN2 for X12SPM-TF/-LN6TF Only) |
| LAN3~6 | 1GbE LAN (RJ45) Ports (LAN3~6 for -LN4F/-LN6TF Only) |

Note: Table is continued on the next page.
Connector Description
| M.2-H M.2 M-Key 2280/22110 Slot (supports PCIe 3.0 x4/SATA3) |
| SLOT4 CPU PCIe 4.0 x16 |
| SLOT6 CPU PCIe 4.0 x16 |
| SLOT7 CPU PCIe 4.0 x8 |
| S-SATA0, S-SATA1 SATA 3.0 Ports with SATA DOM Power |
| S-SGPIO1 Serial Link General Purpose I/O Connection Header |
| TPM1/PORT80 Trusted Platform Module (TPM)/Port 80 Connector |
| USB0/1 Back Panel Universal Serial Bus (USB) 2.0 Ports |
| USB2/3, USB4/5 Front Accessible USB 2.0 Headers |
| USB6/7 Back Panel USB 3.2 Gen 1 Ports |
| USB8/9 Front Accessible USB 3.2 Gen 1 Header |
| USB10 USB 3.2 Gen 1 Type-A Header |
| VGA VGA Port |
Motherboard Features
| Motherboard Features | |
| CPUSupports a 3rd generation Intel Xeon Scalable Processor series (Socket P+ (LGA4189)) with up to 40 cores and a thermal design power (TDP) of up to 270W | |
| MemorySupports up to 2048GB of ECC RDIMM/LRDIMM/LRDIMM 3DS with speeds of up to 3200MHz in eight slots. | |
| [STFE] Note: Memory speed support depends on the processors used in the system. | |
| DIMM SizeUp to 256GB at 1.2V | |
| [SMH] Note: For the latest CPU/memory updates, please refer to our website athttp://www.supermicro.com/products/motherboard. | |
| ChipsetIntel PCH C621A | |
| Expansion SlotsOne PCIe 4.0 x8 Slots (SLOT7)One PCIe 4.0 x16 Slot (CPU SLOT6)One PCIe 4.0 x16 Slot (CPU SLOT4)One M.2 PCIe 3.0 x4/SATA3 slot (M-Key 2280/22110) | |
| NetworkIntel i350 for Quad 1GbE Base-T Ports (X12SPM-LN4F/-LN6TF)Intel X550 for Dual 10GbE Base-T Ports (X12SPM-TF/LN6TF)One Dedicated IPMI LAN located on the rear I/O panel | |
| Baseboard Management Controller (BMC)ASpeed AST2600 BMC | |
| GraphicsGraphics controller via ASpeed AST2600 BMC | |
| I/O DevicesSerial (COM) Port | One front accessible serial port headerEight SATA 3.0 ports at 6 Gb/s with two slimSAS (I-SATA0~7 with RAID 0, 1, 5, 10)Two SATA 3.0 ports with SATA DOM power (S-SATA0, S-SATA1)One VGA connection on the rear I/O panel |
| SATA 3.0Video (VGA) Port | |

Note: The table above is continued on the next page.
Motherboard Features
Peripheral Devices
• Two USB 2.0 ports on the rear I/O panel (USB0/1)
• Two USB 3.2 Gen 1 ports on the rear I/O panel (USB6/7)
- Two front accessible USB 2.0 headers with four (4) USB connections (USB2/3, USB4/5)
• One front accessible USB 3.2 Gen 1 header with two (2) USB connections (USB8/9)
• One USB 3.2 Gen 1 Type-A header (USB10)
BIOS
• 256Mb AMI BIOS SPI Flash BIOS
• ACPI 6.0, Plug and Play (PnP), BIOS rescue hot-key, riser card auto detection support, and SMBIOS 3.0 or later
Power Management
• ACPI power management
• Power button override mechanism
• Power-on mode for AC power recovery
- Wake-on-LAN
• Power supply monitoring
System Health Monitoring
- Onboard voltage monitoring for 2.5V, BMC, 1.2V BMC, 1.15V BMC, +12V, +5V, +3.3V, CPU, Memory, VBAT, +5V stdby, +3.3V stdby, +1.8V PCH, +1.05V PCH, +1.0V PCH, Vcore, Vmem, CPU temperature, VRM temperature, M.2 temperature, PCH temperature, system temperature, and memory temperature
• 7 CPU switch phase voltage regulator
• CPU thermal trip support
• Platform Environment Control Interface (PECI)/TSI
Fan Control
• Fan status monitoring via IPMI connections
• Dual cooling zone
• Low-noise fan speed control
• Five 4-pin fan headers
System Management
• Trusted Platform Module (TPM) support
- SuperDoctor® 5
• Chassis intrusion header and detection
• Server Platform Service
LED Indicators
• CPU/system overheat LED
• Power/suspend-state indicator LED
- Fan Fail LED
- UID/remote UID
- HDD activity LED
• LAN activity LED

Note: The table above is continued on the next page.
Motherboard Features
Dimensions
• 9.6" (L) x 9.6" (W) (243.84mm x 243.84mm)

Note 1: The CPU maximum thermal design power (TDP) is subject to chassis and heatsink cooling restrictions. For proper thermal management, please check the chassis and heatsink specifications for proper CPU TDP sizing.
Note 2: For IPMI configuration instructions, please refer to the Embedded IPMI Configuration User's Guide available at http://www.supermicro.com/support/manuals/.
Note 3: If you purchase a Supermicro Out of Band (OOB) software license key (Supermicro P/N: SFT-OOB-LIC), please do not change the IPMI MAC address. Once you change the IPMI MAC address, the license will be invalid.
Note 4: Supermicro ships standard products with a unique password for the BMC ADMIN user. The password can be found on a label on the motherboard. For general documentation and information on IPMI, please visit our website at: https://www.supermicro.com/en/solutions/management-software/bmc-resources.
Figure 1-3. System Block Diagram

flowchart
graph TD
subgraph CPU
A["CPU"] --> B["PC1-E X15-Gen4"]
A --> C["PC1-E X18-Gen4"]
A --> D["PC1-E X8-Gen4"]
A --> E["PC1-E X4-Gen4"]
A --> F["PE2[0:15"]]
A --> G["PE1[0:15"]]
A --> H["PE0[8:15"]]
A --> I["PE3[0:15"]]
J["PC1-E X4-Gen4"] --> K["PCI-E X15-Gen4"]
J --> L["PCI-E X18-Gen4"]
J --> M["PCI-E X8-Gen4"]
J --> N["PCI-E X4-Gen4"]
O["PC1-E X4-Gen4"] --> P["PCI-E X4-Gen4"]
Q["PC1-E X4-Gen4"] --> R["PCI-E X4-Gen4"]
S["PCI-E X4-Gen4"] --> T["PCI-E X4-Gen4"]
U["PCI-E X4-Gen4"] --> V["PCI-E X4-Gen4"]
W["PCI-E X4-Gen4"] --> X["PCI-E X4-Gen4"]
Y["PCI-E X4-Gen4"] --> Z["PCI-E X4-Gen4"]
AA["PCI-E X4-Gen4"] --> AB["PCI-E X4-Gen4"]
AC["PCI-E X4-Gen4"] --> AD["PCI-E X4-Gen4"]
AE["PCI-E X4-Gen4"] --> AF["PCI-E X4-Gen4"]
AG["PCI-E X4-Gen4"] --> AH["PCI-E X4-Gen4"]
AI["PCI-E X4-Gen4"] --> AJ["PCI-E X4-Gen4"]
AK["PCI-E X4-Gen4"] --> AL["PCI-E X4-Gen4"]
AM["PCI-E X4-Gen4"] --> AN["PCI-E X4-Gen4"]
AO["PCI-E X4-Gen4"] --> AP["PCI-E X4-Gen4"]
AQ["PCI-E X4-Gen4"] --> AR["PCI-E X4-Gen4"]
AS["PCI-E X4-Gen4"] --> AT["PCI-E X4-Gen4"]
AU["PCI-E X4-Gen4"] --> AV["PCI-E X4-Gen4"]
AW["PCI-E X4-Gen4"] --> AX["PCI-E X4-Gen4"]
AY["PCI-EX3-Gen3"] --> AZ["PCH 621A"]
BA["PCH 621A"] --> BB["PCHA 621A"]
end
subgraph PCH 621A
BC["PCHA 621A"] --> BD["PCHA 621A"]
end
subgraph BMC AST2600
BE["BMC AST2600"] --> BF["PCHA 621A"]
end
subgraph CPLD-XO3(324 Pin)
BG["CPLD-XO3(324 Pin)"] --> BH["CPLD NOR Flash"]
BI["CPLD NOR Flash"] --> BJ["CPLD NAND Flash"]
end
subgraph PCH 621A
BK["PCHA 621A"] --> BL["PCHA 621A"]
end
subgraph CPLD-XO3(324 Pin)
BM["CPLD-XO3(324 Pin)"] --> BN["CPLD NOR Flash"]
BO["CPLD NOR Flash"] --> BP["CPLD NAND Flash"]
end
CPU --> PCH_621A
CPU --> BM
CPU --> CPLD-XO3
CPLD-XO3 --> BS["BMC AST2600"]
subgraph PCH_621A
BT["PCHA 621A"] --> BU["PCHA 621A"]
end
subgraph CPLD-XO3(324 Pin)
BV["CPLD-XO3(324 Pin)"]
BW["BMC AST2600"]
CPU --> PCH_621A
CPU --> BM
CPU --> CPLD-XO3
CPLD-XO3 --> BS
CPLD-XO3 --> BW

Note: This is a general block diagram and may not exactly represent the features on your motherboard. See the previous pages for the actual specifications of your motherboard.
1.2 Processor and Chipset Overview
Built upon the functionality and capability of the 3rd generation Intel Xeon Scalable Processor series (Socket P+ (LGA4189)) and the Intel PCH C621A chipset, the X12SPM-TF/-LN4F/-LN6TF motherboard provides system performance, power efficiency, and feature sets to address the needs of next-generation computer users.
With the support of the new Intel Microarchitecture 10nm Process Technology, the dramatically increases system performance for a multitude of server applications.
The Intel PCH C621A chipset provides Enterprise SMbus support, including the following features:
• DDR4 288-pin memory support
• Support for Server Platform Service
• Support of SMBus speeds of up to 400KHz for BMC connectivity
- Improved I/O capabilities to high-storage-capacity configurations
- SPI Enhancements
- Intel Node Manager 4.0 for advanced power monitoring, capping and management for BMC enhancement (see note below).
- BMC supports remote management, virtualization, and the security package for enterprise platforms

Note: Note Manager support depends on the power supply used in your system.
1.3 Special Features
Recovery from AC Power Loss
The Basic I/O System (BIOS) provides a setting that determines how the system will respond when AC power is lost and then restored to the system. You can choose for the system to remain powered off (in which case you must press the power switch to turn it back on), or for it to automatically return to the power-on state. See the Advanced BIOS Setup section for this setting. The default setting is Last State.
1.4 System Health Monitoring
Onboard Voltage Monitors
An onboard voltage monitor will scan the voltages of the onboard chipset, memory, CPU, and battery continuously. Once a voltage becomes unstable, a warning is given, or an error message is sent to the screen. The user can adjust the voltage thresholds to define the sensitivity of the voltage monitor.
Fan Status Monitor with Firmware Control
The system health monitor embedded in the BMC chip can check the RPM status of the cooling fans. The CPU and chassis fans are controlled via IPMI.
Environmental Temperature Control
System Health sensors monitor temperatures and voltage settings of onboard processors and the system in real time via the IPMI interface. Whenever the temperature of the CPU or the system exceeds a user-defined threshold, system/CPU cooling fans will be turned on to prevent the CPU or the system from overheating.

Note: To avoid possible system overheating, please be sure to provide adequate airflow to your system.
System Resource Alert
This feature is available when used with SuperDoctor 5 ^® in the Windows OS or in the Linux environment. SuperDoctor is used to notify the user of certain system events. For example, you can configure SuperDoctor to provide you with warnings when the system temperature, CPU temperatures, voltages and fan speeds go beyond a predefined range.
1.5 ACPI Features
The Advanced Configuration and Power Interface (ACPI) specification defines a flexible and abstract hardware interface that provides a standard way to integrate power management features throughout a computer system, including its hardware, operating system and application software. This enables the system to automatically turn on and off peripherals such as CD-ROMs, network cards, hard disk drives and printers.
In addition to enabling operating system-directed power management, ACPI also provides a generic system event mechanism for Plug and Play, and an operating system-independent interface for configuration control. ACPI leverages the Plug and Play BIOS data structures, while providing a processor architecture-independent implementation that is compatible with appropriate Windows operating systems. For detailed information regarding OS support, please refer to the Supermicro website.
1.6 Power Supply
As with all computer products, a stable power source is necessary for proper and reliable operation. It is even more important for processors that have high CPU clock rates where noisy power transmission is present.
The motherboard accommodates a 24-pin ATX power supply. Although most power supplies generally meet the specifications required by the CPU, some are inadequate. In addition, one 12V 8-pin is also required to ensure adequate power supply to the system.
Warning: To avoid damaging the power supply or the motherboard, use a power supply that contains a 24-pin and an 8-pin power connector. Be sure to connect the power supplies to the 24-pin power connector (JPWR1) and the 8-pin 12V CPU ATX power connector or DC 12V only power connector (JPV1) on the motherboard. Failure in doing so may void the manufacturer warranty on your power supply and motherboard.
It is strongly recommended that you use a high quality power supply that meets ATX power supply Specification 2.02 or above.
1.7 Serial Port
The motherboard supports one serial communication connections. COM Port 1 can be used for input/output. The UART provides legacy speeds with a baud rate of up to 115.2 Kbps.
Chapter 2
Installation
2.1 Static-Sensitive Devices
Electrostatic Discharge (ESD) can damage electronic components. To avoid damaging your system board, it is important to handle it very carefully. The following measures are generally sufficient to protect your equipment from ESD.
Precautions
- Use a grounded wrist strap designed to prevent static discharge.
- Touch a grounded metal object before removing the board from the antistatic bag.
- Handle the motherboard by its edges only; do not touch its components, peripheral chips, memory modules or gold contacts.
- When handling chips or modules, avoid touching their pins.
- Put the motherboard and peripherals back into their antistatic bags when not in use.
- For grounding purposes, make sure that your computer chassis provides excellent conductivity between the power supply, the case, the mounting fasteners and the motherboard.
- Use only the correct type of onboard CMOS battery. Do not install the onboard battery upside down to avoid possible explosion.
Unpacking
The motherboard is shipped in antistatic packaging to avoid static damage. When unpacking the motherboard, make sure that the person handling it is static protected.
2.2 Processor and Heatsink Installation
The processor (CPU) and processor carrier should be assembled together first to form the processor carrier assembly. This will be attached to the heatsink to form the processor heatsink module (PHM) before being installed onto the CPU socket.
Notes:
- Use ESD protection.
- Shut down the system and then unplug the AC power cord from all power supplies.
- Check that the plastic protective cover is on the CPU socket and none of the socket pins are bent. If they are, contact your retailer.
- When handling the processor, avoid touching or placing direct pressure on the LGA lands (gold contacts). Improper installation or socket misalignment can cause serious damage to the processor or CPU socket, which may require manufacturer repairs.
• Thermal grease is pre-applied on new heatsinks. No additional thermal grease is needed.
• Refer to the Supermicro website for updates on processor support. - All graphics in this manual are for illustration purposes only. Your components may look different.
The 3rd generation Intel Xeon Scalable Processor Series

natural_image
Isometric line drawing of a rectangular electronic component or housing (no text or symbols)3rd generation Intel Xeon Scalable Processor
Overview of the Processor Carrier Assembly
The processor carrier assembly contains the3rd generation Intel Xeon Scalable Processor and a processor carrier.
- Processor

natural_image
Isometric line drawing of a rectangular electronic component or enclosure (no text or symbols)- Processor Carrier

natural_image
Isometric technical line drawing of a mechanical or electrical component with no visible text or symbolsOverview of the CPU Socket
The CPU socket is protected by a plastic protective cover.
- Plastic Protective Cover

natural_image
Technical line drawing of a rectangular electronic component with mounting brackets and internal channels (no text or symbols)- CPU Socket

natural_image
Technical line drawing of a mechanical housing or enclosure with multiple bolted components and mounting holes (no text or symbols)Overview of the Processor Heatsink Module
The Processor Heatsink Module (PHM) contains a heatsink, a processor carrier, and the.
- Heatsink with Thermal Grease

natural_image
Technical line drawing of a mechanical component with heat sinks and mounting brackets (no text or symbols)- Processor Carrier

natural_image
Technical line drawing of a mechanical assembly with no visible text or symbols- Processor

natural_image
Pure technical line drawing of a mechanical component or bracket (no text or symbols)Processor Heatsink Module


natural_image
Technical line drawing of a computer motherboard with cooling fans and heatsink (no text or symbols)Creating the 3rd generation Intel Xeon Scalable Processor Carrier Assembly
To install the model processor into the processor carrier, follow the steps below:
-
Hold the processor with the LGA lands (gold contacts) facing up. Locate the small, gold triangle in the corner of the processor and the corresponding hollowed triangle on the processor carrier. These triangles indicate pin 1. The triangles can be found on the top and bottom of the processor. See the images below.
-
Using the triangles as a guide, carefully align and place Point A of the processor into the carrier. Then gently snap-in the other side of the carrier for the processor to fasten into Point B.

Note: The processor carrier contains four metal rings on each corner.
- Examine all corners to ensure that the processor is firmly attached to the carrier.

text_image
Pin 1 A B Allow carrier to fasten onto CPU Allow carrier to fasten onto CPU Allow carrier to fasten onto CPUProcessor Carrier Assembly

Note: The following CPU carriers have been successfully tested in our labs and are available from Supermicro. Please order the CPU carriers with the CPU heatsink.
| Intel 3rd Generation Xeon Scalable Processors | SKT-1205L-P4IC-FXC |
| SKT-1205L-P4IC-TYC |
Assembling the Processor Heatsink Module
After creating the processor carrier assembly for the processor, mount it onto the heatsink to create the processor heatsink module (PHM):
- Note the label on top of the heatsink, which marks the heatsink mounting holes as 1, 2, 3, and 4. If this is a new heatsink, the thermal grease has been pre-applied on the underside. Otherwise, apply the proper amount of thermal grease.
- Turn the heatsink over with the thermal grease facing up. Hold the processor carrier assembly so the processor's gold contacts are facing up, then align the triangle on the assembly with hole 1 of the heatsink. Press the processor carrier assembly down. The plastic clips of the assembly will lock outside of holes 1 and 2, while the remaining clips will snap into their corresponding holes.
- Examine all corners to ensure that the plastic clips on the processor carrier assembly are firmly attached to the heatsink.

text_image
Processor Carrier Assembly {Upside Down} Heatsink {Upside Down} Check each corner to ensure that the processor carrier is firmly attached to the heatsinkPreparing the CPU Socket for Installation
This motherboard comes with a plastic protective cover installed on the CPU socket. Remove it from the socket to install the Processor Heatsink Module (PHM). Gently pull up one corner of the plastic protective cover to remove it.

natural_image
Technical line drawing of a rectangular electronic component with mounting brackets and internal channels (no text or symbols)CPU Socket with Plastic Protective Cover

text_image
Remove the plastic protective cover from the CPU socket. Do not touch or bend the socket pins. Socket PinsInstalling the Processor Heatsink Module
After assembling the Processor Heatsink Module (PHM), install it onto the CPU socket:
- Align hole 1 of the heatsink with the printed triangle on the CPU socket. See the left image below.
- Make sure all four holes of the heatsink are aligned with the socket before gently placing the heatsink on top.
- With a T30 Torx-bit screwdriver, gradually tighten screws #1 - #4 to ensure even pressure. The order of the screws is shown on the label on top of the heatsink. To avoid damaging the processor or socket, do not use a force greater than 12 lbf-in when tightening the screws.
- Examine all corners to ensure that the PHM is firmly attached to the socket.

text_image
Mounting the Processor Heatsink Module onto the CPU socket (on the motherboard) Printed Triangle
text_image
T30 Torx Screwdriver Use a torque of 12 lbf-in #2 #3 #4 #1 Tighten the screws in the sequence of 1, 2, 3, 4Removing the Processor Heatsink Module
Before removing the processor heatsink module (PHM) from the motherboard, shut down the system and then unplug the AC power cord from all power supplies.
Then follow the steps below:
-
Use a T30 Torx-bit screwdriver to loosen the four screws in a backwards sequence of #4, #3, #2, and #1.
-
Gently lift the PHM upwards to remove it from the socket.
-
Move the lever to its unlocked position and gently remove the CPU.

text_image
Remove the screws in the sequence of 4, 3, 2, 1 #2 #3 #1 #4
text_image
CPU Socket
text_image
Move the lever to its unlocked position and gently remove the CPU.2.3 Motherboard Installation
All motherboards have standard mounting holes to fit different types of chassis. Make sure that the locations of all the mounting holes for both the motherboard and the chassis match. Although a chassis may have both plastic and metal mounting fasteners, metal ones are highly recommended because they ground the motherboard to the chassis. Make sure that the metal standoffs click in or are screwed in tightly.
Tools Needed

Phillips
Screwdriver (1)

Phillips Screws (8)

Standoffs (8) Only if Needed

text_image
SUPER X12SPM-LN4F-7F/LN6TF REV: 2.00 DE SEPTE 13 IN USA BAR CODE MAC CODELocation of Mounting Holes

Note: 1) To avoid damaging the motherboard and its components, please do not use a force greater than 8 lbf-in on each mounting screw during motherboard installation. 2) Some components are very close to the mounting holes. Please take precautionary measures to avoid damaging these components when installing the motherboard to the chassis.
Installing the Motherboard
- Install the I/O shield into the back of the chassis, if applicable.

natural_image
Line drawing of a computer setup with a monitor, tower, and ventilation unit (no text or symbols)- Locate the mounting holes on the motherboard. See the previous page for the location.

text_image
Chassis Chassis- Locate the matching mounting holes on the chassis. Align the mounting holes on the motherboard against the mounting holes on the chassis.

text_image
3x5 Motherboard Chassis 3x5 Motherboard Chassis-
Install standoffs in the chassis as needed.
-
Install the motherboard into the chassis carefully to avoid damaging other motherboard components.
-
Using the Phillips screwdriver, insert a pan head #6 screw into a mounting hole on the motherboard and its matching mounting hole on the chassis.
-
Repeat Step 6 to insert #6 screws into all mounting holes.
-
Make sure that the motherboard is securely placed in the chassis.

Note: Images displayed are for illustration only. Your chassis or components might look different from those shown in this manual.
2.4 Memory Support and Installation

Note: Check the Supermicro website for recommended memory modules.

Important: Exercise extreme care when installing or removing DIMM modules to prevent any possible damage.
Memory Support
The supports up to 2048GB of ECC RDIMM/LRDIMM/LRDIMM 3DS with speeds of up to 3200MHz in eight slots. Refer to the tables below for the recommended DIMM population order and additional memory information.
| 1 CPU, 8-DIMM Slots | |
| Number of DIMMs | Memory Population Sequence |
| 1 | DIMMA1 |
| 2 | DIMMA1 / DIMME1 |
| 4 | DIMMA1 / DIMME1 / DIMMC1 / DIMMG1 |
| 6 | DIMMA1 / DIMME1 / DIMMC1 / DIMMG1 / DIMMB1 / DIMMF1 |
| 8 | DIMMA1 / DIMME1 / DIMMC1 / DIMMG1 / DIMMB1 / DIMMF1 / DIMMD1 / DIMMH1 |
| Type | Ranks Per DIMM and Data Width | Dimm Capacity (GB) | Speed (MT/s); Voltage (V); Slot Per Channel (SPC) and DIMM Per Channel (DPC)*Data below assumes 2 SPC unless otherwise noted. | |
| 1DPC | ||||
| 8 Gb 16 Gb | 1.2V | |||
| RDIMM | SRx8 8 GB 16 GB | 3200 | ||
| SRx4 16 GB 32 GB | ||||
| DRx8 16 GB 32 GB | ||||
| DRx4 32GB 64 GB | ||||
| RDIMM-3DS (4R/8R) x4 | 2H-64F GB4H-128 GB | 2H-128 GB4H 256 GB | 3200 | |
| LRDIMM QRx4 | 64 GB 128 GB 3200 | |||
| LRDIMM-3DS (4R/8R) X4 4H-128 GB | 2H-128 GB4H-256 GB | 3200 | ||
General Guidelines for Optimizing Memory Performance
• Always use DDR4 memory of the same type, size and speed.
- Mixed DIMM speeds can be installed. However, all DIMMs will run at the speed of the slowest DIMM.
- The motherboard will support odd-numbered modules (one or three modules installed). However, to achieve the best memory performance, a balanced memory population is recommended.

text_image
SUPER X12SPM-LN4F/-TF/LN6TF REV: 2.00 DESIGNED IN USA CPU BAR CODE MAC CODE DIMMF1 DIMME1 DIMMH1 DIMMG1 DIMMC1 DIMMD1 DIMMA1 DIMMB1DIMM Installation
- Insert the desired number of DIMMs into the memory slots based on the recommended DIMM population table on page 34.
- Push the release tabs outwards on both ends of the DIMM slot to unlock it.
- Align the key of the DIMM module with the receptive point on the memory slot.
- Align the notches on both ends of the module against the receptive points on the ends of the slot.
- Press the notches on both ends of the module straight down into the slot until the module snaps into place.
- Press the release tabs to the lock positions to secure the DIMM module into the slot.
DIMM Removal
Press both release tabs on the ends of the DIMM module to unlock it. Once the DIMM module is loosened, remove it from the memory slot.

text_image
SUPER C:\WINDOWS\WIN\10.0\12\01\03\04\05\06\07\08\09\10\11\12\13\14\15\16\17\18\19\20\21\22\23\24\25\26\27\28\29\30\31\32\33\34\35\36\37\38\39\40\41\42\43\44\45\46\47\48\49\50\51\52\53\54\55\56\57\58\59\60\61\62\63\64\65\66\67\68\69\70\71\72\73\74\75\76\77\78\79\80
natural_image
Technical illustration of a mechanical component with a circular arrow and label (no readable text or symbols)
text_image
NotchesRelease Tabs

text_image
Press both notches straight down into the memory slot.2.5 Rear I/O Ports
See Figure 2-1 below for the locations and descriptions of the various I/O ports on the rear of the motherboard.

text_image
SUPER CPU/PLM/PLM/PLM 1 VAC CODES VAC CODESFigure 2-1. I/O Port Locations and Definitions for -LN4F

text_image
Diagram showing labeled network equipment components including server, ports, and connectors| Rear I/O Ports | |||
| # Description # Description | |||
| 1 VGA Port 7 LAN4 | |||
| 2 Dedicated IPMI LAN 8 LAN3 | |||
| 3 USB1 9 LAN6 | |||
| 4 USB0 10 LAN5 | |||
| 5 USB7 (3.2 Gen 1) 11 UID Switch | |||
| 6 USB6 (3.2 Gen 1) | |||
Figure 2-1. I/O Port Locations and Definitions for -LN6TF

text_image
Diagram of network equipment rack with labeled ports and connectors| Rear I/O Ports | |||
| # Description # Description | |||
| 1 VGA | Port 8 LAN1 (10G on -LN6TF) | ||
| 2 Dedicated IPMI LAN 9 LAN4 | |||
| 3 USB1 | 10 LAN3 | ||
| 4 USB0 | 11 LAN6 | ||
| 5 USB7 | (3.2 Gen 1) 12 LAN5 | ||
| 6 USB6 | (3.2 Gen 1) 13 UID Switch | ||
| 7 LAN2 | (10G on -LN6TF) | ||
Figure 2-1. I/O Port Locations and Definitions for -TF

text_image
Diagram of network equipment rack with labeled components including VGA, Ethernet ports, and a terminal outlet| Rear I/O Ports | ||
| # Description # Description | ||
| 1 VGA Port 6 USB6 (3.2 Gen 1) | ||
| 2 Dedicated IPMI LAN 7 LAN2 (10G on -TF) | ||
| 3 USB1 8 LAN1 (10G on -TF) | ||
| 4 USB0 9 UID Switch | ||
| 5 USB7 (3.2 Gen 1) | ||
VGA Port
A video (VGA) port is located next to IPMI_LAN on the I/O back panel. Refer to the board layout below for the location.
COM Ports
There is one COM connection on this motherboard. COM1 is located next to PCIe Slot 1.
| COM PortPin Definitions | |||
| Pin# Definition Pin# Definition | |||
| 1 DCD | 6 DSR | ||
| 2 RXD | 7 RTS | ||
| 3 TXD | 8 CTS | ||
| 4 DTR | 9 RI | ||
| 5 Ground | 10 N/A | ||

text_image
BVC AST28.00 1 SUPER X125PMH N4FS-TP/LN6TF REV: 2.00 DESIGNED IN USA PC+ 621A BAR CODE MAC CODE CE FC- VGA Port
- COM1
LAN Ports
Up to six LAN ports (LAN1-6) 1/10 Gigabit Ethernet ports are located on the I/O back panel. In addition to the LAN ports, a dedicated IPMI LAN is located above the USB0/1 ports on the back panel. Please refer to the LED Indicator section for LAN LED information.

text_image
SUPER X12SPM LN4F/ TFALN6TF REV. 2.00 DENSTRED NU3A BAR CODE MAC CODE- LAN1/2
- LAN3/4
- LAN 5/6
- IPMI LAN
Universal Serial Bus (USB) Ports
There are two USB 2.0 ports (USB0/1) and two USB 3.2 Gen 1 ports (USB6/7) located on the I/O back panel. The motherboard also has two front access USB 2.0 headers (USB2/3 and USB4/5) and one front access USB 3.2 Gen 1 header (USB8/9). The USB10 header is USB 3.2 Gen 1 Type-A. The onboard headers can be used to provide front side USB access with a cable (not included).
| Back Panel USB 0/1 (2.0) Pin Definitions | |||
| Pin# Definition Pin# Definition | |||
| 1 | +5V | 5 | +5V |
| 2 | USB_N | 6 | USB_N |
| 3 | USB_P | 7 | USB_P |
| 4 | Ground | 8 | Ground |
| Front Panel USB 2/3, 4/5 (2.0) Pin Definitions | |||
| Pin# Definition | Pin# Definition | ||
| 1 | +5V | 2 | +5V |
| 3 | USB_N | 4 | USB_N |
| 5 | USB_P | 6 | USB_P |
| 7 | Ground | 8 | Ground |
| 9 | Key | 10 NC | |
| Back Panel USB 6/7 (3.2 Gen 1)Pin Definitions | ||
| Pin# Definition Pin# Definition | ||
| A1 VBJS B1 VBUS | ||
| A2 USB_N B2 USB_N | ||
| A3 USB_P B3 USB_P | ||
| A4 GND B4 GND | ||
| A5 Stda_SSRX- B5 Stda_SSRX- | ||
| A6 Stda_SSRX+ B6 Stda_SSRX+ | ||
| A7 GND B7 GND | ||
| A8 Stda_SSTX- B8 Stda_SSTX- | ||
| A9 Stda_SSTX+ B9 Stda_SSTX+ | ||
| Front Panel USB 8/9 (3.2 Gen 1) Pin Definitions | ||
| Pin# Definition | Pin# Definition | |
| 1 | VBUS | 19 VBUS |
| 2 | Stda_SSRX- | 18 Stda_SSRX- |
| 3 | Stda_SSRX+ | 17 Stda_SSRX+ |
| 4 | GND | 16 GND |
| 5 | Stda_SSTX- | 15 Stda_SSTX- |
| 6 | Stda_SSTX+ | 14 Stda_SSTX+ |
| 7 | GND | 13 GND |
| 8 | USB_N | 12 USB_N |
| 9 | USB_P 11 USB_P | |
| 10 | NC | |

text_image
4 1 SUPER X120PM-LMT-TRLMETF HOLD ZOOM DESPRING N.QMA BAR CODE MAC CODE 6 5 3 2 1 BNC ASTMOS| Type A USB 10 (3.2 Gen 1) Pin Definitions | |||
| Pin# Definition | Pin# Definition | ||
| 1 | VBUS | 5 | SSRX- |
| 2 | USB_N | 6 | SSRX+ |
| 3 | USB_P | 7 | GND |
| 4 | Ground | 8 | SSTX- |
| 9 | SSTX+ | ||
- USB0/1
- USB2/3
- USB4/5
- USB6/7 (3.2 Gen 1)
- USB8/9 (3.2 Gen 1)
- USB10 (3.2 Gen 1)
Unit Identifier Switch (UID-SW): One button with two functions
A Unit Identifier (UID) switch and two LED Indicators are located on the motherboard. The UID switch, UID-SW, is located next to the VGA port on the back panel.
| Function User Input Behavior LED Activity | |||
| UID LED Indicator | Push Once Turns on the UID LED | LED UID LED turns solid blue | |
| Push Again | Turns off the UID LED | UID LED turns off | |
| BMC Reset | Push and hold for 6 seconds | BMC will do a cold boot | BMC Hearbeat LED turns solid green |
| Push and hold for 12 seconds | BMC will reset to factory default | BMC Hearbeat LED turns solid green | |

Note: After pushing and holding the UID-SW for 12 seconds, all IPMI settings including username and password will revert back to the factory default. Only the network settings and FRU are retained.
| UID Switch Pin Definitions |
| Pin# Definition |
| 1 Button In |
| 2 Ground |
| G1 Ground |
| G2 Ground |
| UID LEDPin Definitions |
| Color Status |
| Blue: On Unit Identified |

text_image
2 1 BMC AST 2600 SUPER X12SPM CN4P7 TF/LN6TF REV: 2.00 DESIGNED IN USA FCH 621A BAR CODE MAC CODE- UID Switch
- UID LED
2.6 Front Control Panel
JF1 contains header pins for various buttons and indicators that are normally located on a control panel at the front of the chassis. These connectors are designed specifically for use with Supermicro chassis. See the figure below for the descriptions of the front control panel buttons and LED indicators.

text_image
SUPER X12SPM-LN4F-/TF/LN6TF REV: 2.00 DESIGNED IN USA PCII 621A BAR CODE MAC CODEFigure 2-2. JF1 Header Pins

text_image
PWR Power Button Reset Reset Button 3.3V UID LED 3.3V Stby 3.3V Stby UID_SW 3.3V Stby X NMI 1 2 Ground Ground Power Fail LED OH/Fan Fail LED NIC2 Active LED NIC1 Active LED HDD LED PWR LED X Ground 19 20Power Button
The Power Button connection is located on pins 1 and 2 of JF1. Momentarily contacting both pins will power on/off the system. This button can also be configured to function as a suspend button (with a setting in the BIOS - see Chapter 4). To turn off the power when the system is in suspend mode, press the button for 4 seconds or longer. Refer to the table below for pin definitions.
| Power ButtonPin Definitions (JF1) |
| Pins Definition |
| 1 Signal |
| 2 Ground |
Reset Button
The Reset Button connection is located on pins 3 and 4 of JF1. Attach it to a hardware reset switch on the computer case to reset the system. Refer to the table below for pin definitions.
| Reset ButtonPin Definitions (JF1) |
| Pins Definition |
| 3 Reset |
| 4 Ground |

text_image
1 PWR 2 Reset Power Button Reset Button 3.3V UID LED 3.3V Stby 3.3V Stby UID_SW 3.3V Stby X NMI 19 20 Ground Ground Power Fail LED OH/Fan Fail LED NIC2 Active LED NIC1 Active LED HDD LED PWR LED X Ground- PWR Button
- Reset Button
Power Fail LED
The Power Fail LED connection is located on pins 5 and 6 of JF1. Refer to the table below for pin definitions.
| Power Fail LEDPin Definitions (JF1) | |
| Pin# | Definition |
| 5 | 3.3V |
| 6 | PWR Supply Fail |
Overheat (OH)/Fan Fail
Connect an LED cable to pins 7 and 8 of the Front Control Panel to use the Overheat/Fan Fail LED connections. The LED on pin 8 provides warnings of overheating or fan failure. Refer to the tables below for pin definitions.
| OH/Fan Fail Indicator Status | |
| State | Definition |
| Off Normal | |
| On Overheat | |
| Flashing Fan Fail | |
| OH/Fan Fail LEDPin Definitions (JF1) | |
| Pin# | Definition |
| 7 | UID LED |
| 8 | OH/Fan Fail LED |

text_image
PWR Reset Power Button Reset Button 3.3V UID LED 3.3V Stby 3.3V Stby UID_SW 3.3V Stby X NMI 19 20 Ground Ground Power Fail LED OH/Fan Fail LED NIC2 Active LED NIC1 Active LED HDD LED PWR LED X Ground- Power Fail LED
- OH/Fan Fail LED
The NIC (Network Interface Controller) LED connection for LAN port 1 is located on pins 11 and 12 of JF1, and LAN port 2 is on pins 9 and 10. Attach the NIC LED cables here to display network activity. Refer to the table below for pin definitions.
| LAN1/LAN2 LEDPin Definitions (JF1) | |
| Pin# | Definition |
| 9 3.3V | Stby |
| 10 NIC | 2 Activity LED |
| 11 3.3V | Stby |
| 12 NIC | 1 Activity LED |
HDD LED/UID Switch
The HDD LED/UID Switch connection is located on pins 13 and 14 of JF1. Attach a cable to pin 13 to use the UID switch. Attach a cable to pin 14 to show hard drive activity status. Refer to the table below for pin definitions.
| HDD LEDPin Definitions (JF1) |
| Pins Definition |
| 13 UID_SW |
| 14 HDD Active |

text_image
PWR Reset Power Button Reset Button 3.3V UID LED 3.3V Stby 3.3V Stby UID_SW 3.3V Stby X NMI 1 2 Ground Ground Power Fail LED OH/Fan Fail LED NIC2 Active LED NIC1 Active LED HDD LED PWR LED X Ground 19 20- NIC2 LED
- NIC1 LED
- HDD LED
Power LED
The Power LED connection is located on pins 15 and 16 of JF1. Refer to the table below for pin definitions.
| Power LEDPin Definitions (JF1) |
| Pins Definition |
| 15 3.3V Stby |
| 16 PWR LED |
NMI Button
The non-maskable interrupt (NMI) button header is located on pins 19 and 20 of JF1. Refer to the table below for pin definitions.
| NMI ButtonPin Definitions (JF1) |
| Pins Definition |
| 19 Control |
| 20 Ground |

text_image
PWR Reset Power Button Reset Button 3.3V UID LED 3.3V Stby 3.3V Stby UID_SW 3.3V Stby X NMI 1 2 Ground Ground Power Fail LED OH/Fan Fail LED NIC2 Active LED NIC1 Active LED HDD LED PWR LED X Ground 19 20-
PWR LED
-
NMI
2.7 Connectors
Power Connections
ATX Power Supply Connector
JPWR1 is a 24-pin power supply connector. You must also connect the 8-pin (JPV1) power connector to the power supply.
| ATX Power 24-pin ConnectorPin Definitions | ||
| Pin# Definition Pin# Definition | ||
| 13 +3.3V 1 +3.3V | ||
| 14 Res (NC) 2 +3.3V | ||
| 15 Ground 3 Ground | ||
| 16 PS_ON 4 +5V | ||
| 17 Ground 5 Ground | ||
| 18 Ground 6 +5V | ||
| 19 Ground 7 Ground | ||
| 20 Res (NC) 8 PWR_OK | ||
| 21 +5V 9 5VSB | ||
| 22 +5V 10 +12V | ||
| 23 +5V 11 +12V | ||
| 24 Ground 12 +3.3V | ||
Required Connection

text_image
SUPPER X12SPM-LN4F-TF/LN6TF REV 2.00 DESIGNED IN USA BAR CODE MAC CODE- 24-Pin PWR
8-Pin Power Connector
JPV1 is an 8-pin 12V DC power input for the CPU that must be connected to the power supply. Refer to the table below for pin definitions.
| 8-pin PowerPin Definitions |
| Pin# Definition |
| 1 - 4 Ground |
| 5 - 8 P12V (12V Power) |
Required Connection
4-Pin Power Output
The 4-pin hard disk drive (HDD) power connector located at JPH1 provides power to onboard HDD devices. Refer to the table below for pin definitions.
| 4-pin HDD Power Pin Definitions | |
| Pin# Definition | |
| 1 12V | |
| 2-3 Ground | |
| 4 5V | |

text_image
SUPER X12SPMLN4F-TFLN6TF REV 2.00 DESIGNED IN USA BAR CODE MAC CODE ① ② ①- 8-Pin PWR
- 4-Pin PWR Output
JLAN LED Connectors
There are two LAN LED activity signal connectors for the front panel. Refer to the tables below for pin definitions.
| JLANLED1 (LN4F/LN6TF only) Pin Definitions | |
| Pin Definition | |
| 1 3.3V | Stby |
| 2 | NIC5 LED for LN4F; NIC3 Active LED for LN6TF |
| 3 3.3V | Stby |
| 4 | NIC6 Active LED for LN4F; NIC4 Active LED for LN6TF |
| JLANLED2 (LN4F/LN6TF only) Pin Definitions | |
| Pin Definition | |
| 1 3.3V | Stby |
| 2 NIC5 | Active LED for LN6TF |
| 3 3.3V | Stby |
| 4 NIC6 | Active LED for LN6TF |

text_image
SUPER X12SPM-LN4F7-TF/LN5TF REV. 2.00 DE SCORE D IN USA FCH 301A BAR CODE MAC CODE- JLANLED1 Connector
- JLANLED2 Connector
Headers
Fan Headers
There are five 4-pin fan headers (FAN1 \~ FAN4, FANA) on the motherboard. All these 4-pin fan headers are backwards compatible with the traditional 3-pin fans. However, fan speed control is available for 4-pin fans only by Thermal Management via the IPMI 2.0 interface. Refer to the table below for pin definitions.
| Fan HeaderPin Definitions | |
| Pin# Definition | |
| 1 Ground (Black) | |
| 2 5A/+12V (Red) | |
| 3 Tachometer | |
| 4 PWM_Control |

text_image
BMC AST2630 SUPER X-28PM-LN1F-TFLN6TF REV 2.00 DESIGNED IN USA PC4 921A BAR CODE MAC CODE 1 4 3 2 5- FANA
- FAN1
- FAN2
- FAN3
- FAN4
SGPIO Headers
There is one Serial Link General Purpose Input/Output (S-SGPIO1) header located on the motherboard. S-SGPIO is for sSATA use. Refer to the tables below for pin definitions.
| SGPIO HeaderPin Definitions | |
| Pin# Definition Pin# Definition | |
| 1 NC 2 NC | |
| 3 Ground 4 Data | |
| 5 Load 6 Ground | |
| 7 Clock 8 NC | |
NC = No Connection
Disk-On-Module Power Connector
The Disk-On-Module (DOM) power connectors at JSD1 and JSD2 provide 5V power to a solid state DOM storage device connected to one fo the SATA ports. Refer to the table below for pin definitions.
| DOM Power Pin Definitions | |
| Pin# Definition | |
| 1 5V | |
| 2 Ground | |
| 3 Ground | |

text_image
SUPER X12SPM LN4F7 TF/LN6TF DEV: 2.30 DESHED IN USA BAR CODE MAC CODE- S-SGPIO1
- JSD1 (DOM PWR)
- JSD2 (DOM PWR)
TPM/Port 80 Header
A Trusted Platform Module (TPM)/Port 80 header is located at JTPM1 to provide TPM support and Port 80 connection. Use this header to enhance system performance and data security. Refer to the table below for pin definitions. Please go to the following link for more information on the TPM: http://www.supermicro.com/manuals/other/TPM.pdf.
| Trusted Platform Module HeaderPin Definitions | ||
| Pin# Definition Pin# Definition | ||
| 1 +3.3V 2 SPI_CS# | ||
| 3 RESET# 4 SPI_MISO | ||
| 5 SPI_CLK 6 GND | ||
| 7 SPI_MOSI 8 NC | ||
| 9 +3.3V Stdby 10 SPI_IRQ# | ||
Standby Power
The Standby Power header is located at JSTBY1 on the motherboard. You must have a card with a Standby Power connector and a cable to use this feature. Refer to the table below for pin definitions.
| Standby Power Pin Definitions | |
| Pin# Definition | |
| 1 +5V | Standby |
| 2 Ground | |
| 3 No Connection | |

text_image
BMC X12SPM-LN4-F-1F-LN6TF REV 2.00 DESHINED IN USA ① ② SUPER X12SPM-LN4-F-1F-LN6TF BAR CODE MAC CODE- TPM Header
- Standby Power
Power SMB (I²C) Header
The Power System Management Bus (I²C) connector (JPI²C1) monitors the power supply, fan, and system temperatures. Refer to the table below for pin definitions.
| Power SMB HeaderPin Definitions | |
| Pin# | Definition |
| 1 | Clock |
| 2 | Data |
| 3 | PMBUS_Alert |
| 4 | Ground |
| 5 | +3.3V |
NVMe I²C Header
Connector JNVI ^2 C1 is a management header for the Supermicro AOC NVMe PCIe peripheral cards. Please connect the ^2 C cable to this connector.
| NVMe I2C Header Pin Definitions | |
| Pin# | Definition |
| 1 | Data |
| 2 | GND |
| 3 | Clock |
| 4 | +3.3V |

text_image
2 SUPER X12SPM LN4F-TP/LN8TF REV. 2.00 D:\SCRED IN USA 1 BAR CODE MAC CODE A1 BMC AST/2630 CNC GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND- Power SMB Header
- NVMe I²C Header
Chassis Intrusion
A Chassis Intrusion header is located at JL1 on the motherboard. Attach the appropriate cable from the chassis to inform you of a chassis intrusion when the chassis is opened. Refer to the table below for pin definitions.
| Chassis Intrusion Pin Definitions |
| Pin# Definition |
| 1 Intrusion Input |
| 2 Ground |
External (I²C) Header
The system management bus header is located at JIPMB1. Connect the appropriate cable here to use the IPMB I2C connection on your system. Refer to the table below for pin definitions.
| SMBus HeaderPin Definitions | |
| Pin# Definition | |
| 1 Data | |
| 2 GND | |
| 3 Clock | |
| 4 NC | |

text_image
SUPER X 25PM LN4Y-TFLN6TF REV 2.00 DESIGNED IN USA BAR CODE MAC CODE- Chassis Intrusion
- Power SMB (I²C) Header
Speaker
The speaker is located at JD1. Please note that the speaker connector pins (1-4) are used with an external speaker. Refer to the tables below for pin definitions.
| Speaker Connector Pin Definitions | |
| Pin# Signal | |
| 1 P5V | |
| 4 R_SPKPIN | |
Intel RAID Key Header
The JRK1 header allows the user to enable RAID functions for NVMe connections. Refer to the table below for pin definitions.
| Intel RAID Key HeaderPin Definitions | |
| Pin# Definition | |
| 1 GND | |
| 2 3.3V Stdby | |
| 3 | GND |
| 4 | PCH RAID KEY |

text_image
SUPER X125TM-LN4F-TF/LN6TF REV 2.30 DESIGNED IN USA FC1 821A BAR CODE MAC CODE- Speaker
- Intel RAID Key Header
SATA Ports
Eight SATA 3.0 ports are located on the X12SPM-TF/-LN4F/-LN6TF motherboard supported by the C621A chipset via two slimSAS connectors. These SATA ports support RAID 0, 1, 5, and 10. In addition, there are also two S-SATA ports (S-SATA0, S-SATA1) that include SATA DOM power. SATA ports provide serial-link signal connections, which are faster than the connections of Parallel ATA. Refer to the tables below for pin definitions.

Note: For more information on the SATA HostRAID configuration, please refer to the Intel SATA HostRAID user's guide posted on our website at http://www.supermicro.com.
| SATA 3.0 Ports Pin Definitions | |
| Pin# Definition | |
| 1 Ground | |
| 2 SATA_TXP | |
| 3 SATA_TXN | |
| 4 Ground | |
| 5 SATA_RXN | |
| 6 SATA_RXP | |
| 7 NC |
M.2 Slot
The X12SPM-RF/-LN4F/-LN6TF motherboard has one M.2 slot. M.2 was formerly known as Next Generation Form Factor (NGFF) and serves to replace mini PCIe. M.2 allows for a variety of card sizes, increased functionality, and spacial efficiency. The M.2 socket on the motherboard supports PCIe 3.0 x4 32Gb/s_/SATA SSD cards in the 2280 and 22110 form factors.

text_image
EAC A37200 SUPER X125FM-LNMF-TF/LN6TF REV. 2.00 DESIGNED IN USA PCN 621A BAR CODE MAC CODE 1 2 4 3- JS1 (I-SATA0-3)
- JS2 (I-SATA4-7)
- S-SATA0
- S-SATA1
- M.2 Slot
NVM Express Connections
There are two Slimline SAS connectors located on the motherboard to support two PCIe 4.0 x4 NVMe connections. This connector provides high-speed and low-latency connections directly from the CPU to NVMe Solid State (SSD) drives. This greatly increases SSD data-throughput performance and significantly reduces PCIe latency by simplifying driver/software requirements resulting from direct PCIe interface from the CPU to the NVMe SSD drives.
| NVME0/1 ConnectorPin Definitions | |||||||
| Pin# | Definition | Pin# | Definition | Pins# | Definition | Pins# | Definition |
| 1 GND | 11 SBA+ 21 | RX4N 31 | GND | ||||
| 2 RX0P | 12 SBA- 22 | GND | 32 RX6P | ||||
| 3 RX0N | 13 GND | 23 | RX5P 33 | RX6N | |||
| 4 GND | 14 R2XP 24 | RX5N 34 GND | |||||
| 5 RX1P | 15 RX2N | 25 | GND 35 | RX7P | |||
| 6 | RX1N | 16 | GND | 26 | SB7B | 36 | RX7N |
| 7 GND | 17 RX3P 27 | SB4B 37 GND | |||||
| 8 SB7A | 18 RX3N | 28 GND | |||||
| 9 SB4A | 19 GND | 29 SBB+ | |||||
| 10 | GND 20 RX4P 30 | SBB- | |||||

text_image
BMC X125FM-LN4E-TR-LNGTF REV: 2.00 DESIGNED NUSA SUPER X125FM-LN4E-TR-LNGTF BAR CODE MAC CODE-
JNVME0 Connection
-
JNVME1 Connection
2.8 Jumper Settings
How Jumpers Work
To modify the operation of the motherboard, jumpers can be used to choose between optional settings. Jumpers create shorts between two pins to change the function of the connector. Pin 1 is identified with a square solder pad on the printed circuit board. See the diagram below for an example of jumping pins 1 and 2. Refer to the motherboard layout page for jumper locations.

Note: On two-pin jumpers, "Closed" means the jumper is on and "Open" means the jumper is off the pins.

text_image
Connector Pins Jumper Setting 3 2 1 3 2 1CMOS Clear
JBT1 is used to clear CMOS, which will also clear any passwords. Instead of pins, this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS.
To Clear CMOS
-
First power down the system and unplug the power cord(s).
-
Remove the cover of the chassis to access the motherboard.
-
Remove the onboard battery from the motherboard.
-
Short the CMOS pads with a metal object such as a small screwdriver for at least four seconds.
-
Remove the screwdriver (or shorting device).
-
Replace the cover, reconnect the power cord(s), and power on the system.

Note: Clearing CMOS will also clear all passwords.
Do not use the PW_ON connector to clear CMOS.

JBT1 contact pads

text_image
SUPER X125PM-LN47-TF/LN6TF REV 2.00 DESIGNED IN USA BAR CODE MAC CODE- CMOS Clear
1GbE LAN Enable/Disable
JPL1 allows you to enable or disable the 1GbE LAN for the -LN4F and -LN6TF motherboards. The default setting is Enabled.
| 1GbE LAN Enable/Disable Jumper Settings | |
| Jumper Setting Definition | |
| Pins 1-2 Enable | |
| Pins 2-3 Disable | |
10GbE LAN Enable/Disable
JTPG1 allows you to enable or disable the 10GbE LAN ports on the -TF and -LN6TF motherboards.
| 10GbE LAN Enable/Disable Jumper Settings | |
| Jumper Setting Definition | |
| Pins 1-2 Enable | |
| Pins 2-3 Disable | |

text_image
BMC 125PM-LN4P-TPLNETF REV 2.00 DESIGNED IN USA SUPER X12SPM-LN4P-TPLNETF 1 BAR CODE MAC CODE2
- 10G LAN Enable/Disable
- 1G LAN Enable/Disable
ME Manufacturing
ME Recovery (JPME2) is used to enable or disable the ME Recovery feature of the motherboard. The jumper will reset Intel ME values back to their default settings.
| Manufacturing ModeJumper Settings | |
| Jumper Setting Definition | |
| Pins 1-2 Normal | |
| Pins 2-3 Manufacturing Mode | |

text_image
SUPER X12SPM LNAFTFLNETF REV. Z00 DE SICLN DIN USA PCH SPTA BAR CODE MAC CODE- Manufacturing Mode
2.9 LED Indicators
LAN LEDs
Six LAN ports (LAN1\~6) are located on the back I/O panel of the motherboard. Each Ethernet LAN port has two LEDs. The yellow LED indicates activity, while the other Link LED may be green, amber, or off to indicate the speed of the connection. Refer to the tables below for more information.
| LAN Activity LED for 1GbE (Left)LED State | ||
| Color Status Definition | ||
| Yellow Flashing Active | ||
| LAN Link LED for 1GbE (Right)LED State | |
| LED Color Definition | |
| Off No Connection/10Mbps | |
| Amber 1 Gbps | |
| Green 100 Mbps | |
| LAN Activity LED for 10GbE (Left)LED State | ||
| Color Status Definition | ||
| Yellow Flashing Active | ||
| LAN Link LED for 10GbE (Right)LED State | |
| LED Color Definition | |
| Off No Connection | |
| Amber 1 Gbps | |
| Green 10 Gbps | |

text_image
SUPER X125PM-LN47-TF/LN6TF REV. 2.00 DESIGNED IN USA BAR CODE MAC CODE- LAN 1\~6 LED
IPMI LAN LEDs
In addition to LAN ports, an IPMI LAN is also located on the I/O back panel. The amber LED on the right indicates activity, while the green LED on the left indicates the speed of the connection. Refer to the table below for more information.

text_image
IPMI LAN Link LED Activity LED| IPMI LAN LEDs | ||
| Color/State Definition | ||
| Link (left) | Green: SolidAmber: Solid | 100 Mbps1Gbps |
| Activity (Right) Amber: Blinking Active | ||
BMC Heartbeat LED
A BMC Heartbeat LED is located at LEDM1 on the motherboard. When LEDBMC is blinking, the BMC is functioning normally. Refer to the table below for more information.
| BMC Heartbeat LED Indicator | |
| LED Color Definition | |
| Green:Blinking | BMC Normal |

text_image
SUPER X125PM-LN4F7-TP/LN6TF REV. 2.00 DESIGNED IN USA BAR CODE MAC CODE- Dedicated IPMI LAN LED
- BMC Heartbeat LED
Onboard Power LED
The Onboard Power LED is located at LEDPWR on the motherboard. When this LED is on, the system is on. Be sure to turn off the system and unplug the power cord before removing or installing components. Refer to the table below for more information.
| Onboard Power LED Indicator | |
| LED Color Definition | |
| Off | System Off(power cable not connected) |
| Green System | On |
Unit ID LED
A rear UID LED indicator (UID-LED1) is located near the UID switch on the I/O back panel. This UID indicator provides easy identification of a system unit that may need service.
| UID LEDLED Indicator | |
| LED Color Definition | |
| Blue: On Unit | Identified |

text_image
SUPER X12SPM-LN4I-TP/LN4TF REV: 2.00 12 SIGN IN USA BAR CODE MAC CODE- Onboard Power LED
- Unit ID LED
Chapter 3
Troubleshooting
3.1 Troubleshooting Procedures
Use the following procedures to troubleshoot your system. If you have followed all of the procedures below and still need assistance, refer to the 'Technical Support Procedures' and/or 'Returning Merchandise for Service' section(s) in this chapter. Always disconnect the AC power cord before adding, changing or installing any non hot-swap hardware components.
Before Power On
- Make sure that there are no short circuits between the motherboard and chassis.
- Disconnect all ribbon/wire cables from the motherboard, including those for the keyboard and mouse.
- Remove all add-on cards.
- Install the CPU (making sure it is fully seated) and connect the front panel connectors to the motherboard.
No Power
- Make sure that there are no short circuits between the motherboard and the chassis.
- Make sure that the ATX power connectors are properly connected.
- Check that the 115V/230V switch, if available, on the power supply is properly set.
- Turn the power switch on and off to test the system, if applicable.
- Check the CPU socket for bent pins and make sure it is fully seated.
- The battery on your motherboard may be old. Check to verify that it still supplies \~3VDC. If it does not, replace it with a new one.
System Boot Failure
If the system does not display POST (Power-On-Self-Test) or does not respond after the power is turned on, do the following:
- Check the screen for an error message.
- Clear the CMOS settings by unplugging the power cord and contacting both pads on the CMOS clear jumper (JBT1). Restart the system. Refer to Section 2-8 in Chapter 2.
- Remove all components from the motherboard and turn on the system with only one DIMM module installed. If the system boots, turn off the system and re-populate the components back into the system to retest. Add one component at a time to isolate which one may have cuased the system boot issue.
Memory Errors
When suspecting faulty memory is causing the system issue, check the following:
- Make sure that the memory modules are compatible with the system and are properly installed. See Chapter 2 for installation instructions. (For memory compatibility, refer to the "Tested Memory List" link on the motherboard's product page to see a list of supported memory.)
- Check if different speeds of DIMMs have been installed. It is strongly recommended that you use the same RAM type and speed for all DIMMs in the system.
- Make sure that you are using the correct type of ECC DDR4 modules recommended by the manufacturer.
- Check for bad DIMM modules or slots by swapping a single module among all memory slots and check the results.
Losing the System's Setup Configuration
- Make sure that you are using a high-quality power supply. A poor-quality power supply may cause the system to lose the CMOS setup information. Refer to Chapter 2 for details on recommended power supplies.
- The battery on your motherboard may be old. Check to verify that it still supplies \~3VDC. If it does not, replace it with a new one.
- If the above steps do not fix the setup configuration problem, contact your vendor for repairs.
When the System Becomes Unstable
A. If the system becomes unstable during or after OS installation, check the following:
-
CPU/BIOS support: Make sure that your CPU is supported and that you have the latest BIOS installed in your system.
-
Memory support: Make sure that the memory modules are supported by testing the modules using memtest86 or a similar utility.

Note: Click on the "Tested Memory List" link on the motherboard's product page to see a list of supported memory.
- HDD support: Make sure that all hard disk drives (HDDs) work properly. Replace the bad HDDs with good ones.
- System cooling: Check the system cooling to make sure that all heatsink fans and CPU/system fans, etc., work properly. Check the hardware monitoring settings in the IPMI to make sure that the CPU and system temperatures are within the normal range. Also check the front panel Overheat LED and make sure that it is not on.
- Adequate power supply: Make sure that the power supply provides adequate power to the system. Make sure that all power connectors are connected. Please refer to our website for more information on the minimum power requirements.
- Proper software support: Make sure that the correct drivers are used.
B. If the system becomes unstable before or during OS installation, check the following:
- Source of installation: Make sure that the devices used for installation are working properly, including boot devices such as CD/DVD.
- Cable connection: Check to make sure that all cables are connected and working properly.
- Using the minimum configuration for troubleshooting: Remove all unnecessary components (starting with add-on cards first), and use the minimum configuration (but with the CPU and a memory module installed) to identify the trouble areas. Refer to the steps listed in Section A above for proper troubleshooting procedures.
- Identifying bad components by isolating them: If necessary, remove a component in question from the chassis, and test it in isolation to make sure that it works properly. Replace a bad component with a good one.
-
Check and change one component at a time instead of changing several items at the same time. This will help isolate and identify the problem.
-
To find out if a component is good, swap this component with a new one to see if the system will work properly. If so, then the old component is bad. You can also install the component in question in another system. If the new system works, the component is good and the old system has problems.
3.2 Technical Support Procedures
Before contacting Technical Support, please take the following steps. Also, please note that as a motherboard manufacturer, Supermicro also sells motherboards through its channels, so it is best to first check with your distributor or reseller for troubleshooting services. They should know of any possible problems with the specific system configuration that was sold to you.
- Please go through the Troubleshooting Procedures and Frequently Asked Questions (FAQ) sections in this chapter or see the FAQs on our website (http://www.supermicro.com/FAQ/index.php) before contacting Technical Support.
- BIOS upgrades can be downloaded from our website (http://www.supermicro.com/ResourceApps/BIOS_IPMI_Intel.html).
-
If you still cannot resolve the problem, include the following information when contacting Supermicro for technical support:
-
Motherboard model and PCB revision number
- BIOS release date/version (This can be seen on the initial display when your system first boots up.)
-
System configuration
-
An example of a Technical Support form is on our website at http://www.supermicro.com/RmaForm/.
- Distributors: For immediate assistance, please have your account number ready when placing a call to our Technical Support department. We can be reached by email at support@supermicro.com.
3.3 Frequently Asked Questions
Question: What type of memory does my motherboard support?
Answer: The motherboard supports DDR4 ECC RDIMM, LRDIMM, or 3DS LRDIMM modules. To enhance memory performance, do not mix memory modules of different speeds and sizes. Please follow all memory installation instructions given on Section 2-4 in Chapter 2.
Question: How do I update my BIOS?
Answer: It is recommended that you do not upgrade your BIOS if you are not experiencing any problems with your system. Updated BIOS files are located on our website at http://www.supermicro.com/ResourceApps/BIOS_IPMI_Intel.html. Please check our BIOS warning message and the information on how to update your BIOS on our website. Select your motherboard model and download the BIOS file to your computer. Also, check the current BIOS revision to make sure that it is newer than your BIOS before downloading.
Unzip the BIOS file onto a bootable USB device and then boot into the built-in UEFI Shell and type "flash.nsh
Warning: Do not shut down or reset the system while updating the BIOS to prevent possible system boot failure! Please read the X12_AMI_BIOS_Uppgrade_README file carefully before you perform the BIOS update.
3.4 Battery Removal and Installation
Battery Removal
To remove the onboard battery, follow the steps below:
- Power off your system and unplug your power cable.
- Locate the onboard battery as shown below.
- Using a tool such as a pen or a small screwdriver, push the battery lock outwards to unlock it. Once unlocked, the battery will pop out from the holder.
- Remove the battery.
Proper Battery Disposal
Warning: Please handle used batteries carefully. Do not damage the battery in any way; a damaged battery may release hazardous materials into the environment. Do not discard a used battery in the garbage or a public landfill. Please comply with the regulations set up by your local hazardous waste management agency to dispose of your used battery properly.
Battery Installation
- To install an onboard battery, follow steps 1 and 2 above and continue below:
- Identify the battery's polarity. The positive (+) side should be facing up.
- Insert the battery into the battery holder and push it down until you hear a click to ensure that the battery is securely locked.
Warning: When replacing a battery, be sure to only replace it with the same type.

text_image
LITHIUM BATTERY BATTERY HOLDER OR LITHIUM BATTERY BATTERY HOLDER3.5 Returning Merchandise for Service
A receipt or copy of your invoice marked with the date of purchase is required before any warranty service will be rendered. You can obtain service by calling your vendor for a Returned Merchandise Authorization (RMA) number. When returning the motherboard to the manufacturer, the RMA number should be prominently displayed on the outside of the shipping carton, and the shipping package is mailed prepaid or hand-carried. Shipping and handling charges will be applied for all orders that must be mailed when service is complete. For faster service, you can also request a RMA authorization online (http://www.supermicro.com/RmaForm/).
This warranty only covers normal consumer use and does not cover damages incurred in shipping or from failure due to the alternation, misuse, abuse or improper maintenance of products.
During the warranty period, contact your distributor first for any product problems.
Chapter 4
UEFI BIOS
4.1 Introduction
This chapter describes the AMIBIOS™ Setup utility for the motherboard. The BIOS is stored on a chip and can be easily upgraded using a flash program.

Note: Due to periodic changes to the BIOS, some settings may have been added or deleted and might not yet be recorded in this manual. Please refer to the Manual Download area of our website for any changes to the BIOS that may not be reflected in this manual.
Starting the Setup Utility
To enter the BIOS Setup Utility, hit the
The Main BIOS screen has two main frames. The left frame displays all the options that can be configured. "Grayed-out" options cannot be configured. The right frame displays the key legend. Above the key legend is an area reserved for a text message. When an option is selected in the left frame, it is highlighted in white. Often a text message will accompany it. (Note that the BIOS has default text messages built in. We retain the option to include, omit, or change any of these text messages.) Settings printed in Bold are the default values.
A "▶" indicates a submenu. Highlighting such an item and pressing the
The BIOS setup utility uses a key-based navigation system called hot keys. Most of these hot keys (
4.2 Main Setup
When you first enter the AMI BIOS setup utility, you will enter the Main setup screen. You can always return to the Main setup screen by selecting the Main tab on the top of the screen. The Main BIOS setup screen is shown below and the following items will be displayed:

text_image
Antio Setup - AMI Main Advanced Event Logs IFMI Security Boot Save & Exit System Date [Wed 12/02/2020] System Time [01:05:01] Supermicro K12SPM-LN6TF BIOS Version 1.00 Build Date 11/20/2020 CPLD Version F1.00.00 Memory Information Total Memory 65536 MB Set the Date. Use Tab to switch between Date elements. Default Ranges: Year: 1598-9999 Months: 1-12 Days: Dependent on month Range of Years may vary. ++: Select Screen TI: Select Item Enter: Select +/-: Change Opt. F1: General Help F2: Previous Values F3: Optimized Defaults F4: Save & Exit ESC: Exit Version 2.21.1278 Copyright (C) 2020 ANISystem Date/System Time
Use this option to change the system date and time. Highlight System Date or System Time using the arrow keys. Enter new values using the keyboard. Press the

Note: The time is in the 24-hour format. For example, 5:30 P.M. appears as 17:30:00. The date's default value is the BIOS build date after RTC reset.
Supermicro X12SPM-LN6TF
BIOS Version
This feature displays the version of the BIOS ROM used in the system.
Build Date
This feature displays the date when the version of the BIOS ROM used in the system was built.
CPLD Version
This feature displays the Complex Programmable Logic Device version.
Memory Information
Total Memory
This feature displays the total size of memory available in the system.
4.3 Advanced
Use the arrow keys to select the Advanced menu and press

text_image
Antio Setup - AMI Main Advanced Event Logs IFMI Security Boot Save & Exit Boot Feature CPU Configuration Chipset Configuration Server ME Information FCH SATA Configuration FCH sSATA Configuration Network Configuration KMIP Server Configuration PCIe/PCI/FnP Configuration Super IO Configuration Serial Port Console Redirection ACPI Settings Trusted Computing HTTP Boot Configuration iSCSI Configuration Intel(R) Ethernet Controller X550 - Intel(R) Ethernet Controller X550 - Intel(R) I350 Gigabit Network Connection - Intel(R) I350 Gigabit Network Connection - Intel(R) I350 Gigabit Network Connection - Intel(R) I350 Gigabit Network Connection - TLS Authenticate Configuration Intel(R) Virtual RAID on CPU Boot Feature Configuration Page ++: Select Screen ↑: Select Item Enter: Select +/-: Change Opt. F1: General Help F2: Previous Values F3: Optimized Defaults F4: Save & Exit ESC: Exit Version 2.21.1278 Copyright (C) 2020 AMIWarning: Take caution when changing the Advanced settings. An incorrect value, a very high DRAM frequency, or an incorrect DRAM timing setting may make the system unstable. When this occurs, revert to default manufacturer settings.
▶Boot Feature
Quiet Boot
Use this feature to select the screen display between the POST messages and the OEM logo upon boot up. Select Disabled to display the POST messages. Select Enabled to display the OEM logo instead of the normal POST messages. The options are Disabled and Enabled.
Option ROM Messages
Use this feature to set the display mode for the Option ROM. Select Keep Current to display the current AddOn ROM setting. Select Force BIOS to use the Option ROM display set by the system BIOS. The options are Force BIOS and Keep Current.
Bootup NumLock State
Use this feature to set the Power-on state for the
Wait For "F1" If Error
Use this feature to force the system to wait until the F1 key is pressed if an error occurs. The options are Disabled and Enabled.
INT19 (Interrupt 19) Trap Response
Interrupt 19 is the software interrupt that handles the boot disk function. When this feature is set to Immediate, the ROM BIOS of the host adapters will "capture" Interrupt 19 at boot up immediately and allow the drives that are attached to these host adapters to function as bootable disks. If this feature is set to Postponed, the ROM BIOS of the host adapters will not capture Interrupt 19 immediately and allow the drives attached to these adapters to function as bootable devices at boot up. The options are Immediate and Postponed.
Re-try Boot
If this feature is enabled, the BIOS automatically reboots the system from a specified boot device after its initial boot failure. The options are Disabled, Legacy Boot, and EFI Boot.
Power Configuration
Watch Dog Function
If enabled, the Watch Dog Timer allows the system to reset or generate NMI when it has expired for more than five minutes. The options are Disabled and Enabled.
*If the feature above is set to Enabled, Watch Dog Action is available for configuration:
Watch Dog Action
Use this feature to reset the system or generate NMI. The options are Reset and NMI.
Restore on AC Power Loss
Use this feature to set the power state after a power outage. Select Stay Off for the system power to remain off after a power loss. Select Power On for the system power to be turned on after a power loss. Select Last State to allow the system to resume its last power state before a power loss. The options are Stay Off, Power On, and Last State.
Power Button Function
This feature controls how the system shuts down when the power button is pressed. Select 4 Seconds Override for you to power off the system after pressing and holding the power button for four seconds or longer. Select Instant Off to instantly power off the system as soon as you press the power button. The options are Instant Off and 4 Seconds Override.
▶CPU Configuration
The following CPU information is displayed:
- Processor BSP Revision
- Processor Socket
- Processor ID
- Processor Frequency
- Processor Max Ratio
- Processor Min Ratio
- Microcode Revision
• L1 Cache RAM (Per Core)
• L2 Cache RAM (Per Core)
• L3 Cache RAM (Per Package) - Processor 0 Version
▶CPU1 Core Disable Bitmap
CPU1 Core Disable Bitmap
Core Disable Bitmap(Hex)
Select 0 to enable all cores or FFFFFFFFFF to disable all cores. One core must be enabled.
Hyper-Threading (ALL)
Select Enable to support Intel Hyper-hreading Technology to enhance CPU performance. The options are Disable and Enable.
Hardware Prefetcher
If set to Enable, the hardware prefetcher prefetches streams of data and instructions from the main memory to the L2 cache to improve CPU performance. The options are Enable and Disable.
Adjacent Cache Prefetch
The CPU prefetches the cache line for 64 bytes if this feature is set to Disabled. The CPU prefetches both cache lines for 128 bytes as comprised if this feature is set to Enable. The options are Enable and Disable.
DCU Streamer Prefetcher (Available when supported by the CPU)
Select Enable to enable the Data Cache Unit (DCU) Streamer Prefetcher, which streams and prefetches data and send it to the Level 1 data cache to improve data processing and system performance. The options are Enable and Disable.
DCU IP Prefetcher (Available when supported by the CPU)
Select Enable for Data Cache Unit (DCU) IP Prefetcher support, which prefetches IP addresses to improve network connectivity and system performance. The options are Enable and Disable.
LLC Prefetch
If set to Enable, the hardware prefetcher prefetches streams of data and instructions from the main memory to the L3 cache to improve CPU performance. The options are Disable and Enable.
Extended APIC
Select Enable to activate Advanced Programmable Interrupt Controller (APIC) support. The options are Disable and Enable.
VMX
Use this feature to enable or disable Vanderpool Technology. The options are Disable and Enable.
Enable SMX
Use this feature to enable or disable Safer Mode Extensions. The options are Disable and Enable.
PPIN Control
Select Unlock/Enable to use the Protected Processor Inventory Number (PPIN) in the system. The options are Unlock/Disable and Unlock/Enable.
AES-NI
Select Enable to use the Intel Advanced Encryption Standard (AES) New Instructions (NI) to ensure data security. The options are Disable and Enable.
TME, TME-MT, TDX
Total Memory Encryption (TME)
Use this feature to enable or disable total memory encryption. The options are Disabled and Enabled.
*If the feature above is set to Enabled, the next five features are displayed:
Total Memory Encryption Multi-Tenant (TME-MT)
Max TME-MT Keys
Software Guard Extension (SGX)
SGX Factory Reset
SW Guard Extensions (SGX)
SGX Package Into In-Band Access
Limit CPU PA to 46 Bits
Use this feature to limit the CPU physical address to 46 bits to support older hyper-v. The options are Disable and Enable.
▶ Advanced Power Management Configuration
Power Technology
Use this feature to enable or disable processor power management features. The options are Disable, Energy Efficient, and Custom.
Power Performance Tuning
Use this feature to select whether the BIOS or the operating system chooses energy performance tuning. The options are OS Controls EPB and BIOS Controls EPB.
*If the feature above is set to BIOS Controls EPB, the next feature is available for configuration:
ENERGY\_PERF\_BIAS CFG Mode
Use this feature to set the energy performance bias. The options are Maximum Performance, Performance, Balanced Performance, Balanced Power, and Power.
▶CPU P State Control
SpeedStep (Pstates)
Intel SpeedStep Technology allows the system to automatically adjust processor voltage and core frequency to reduce power consumption and heat dissipation. The options are Disable and Enable.
Dynamic SST-PP
Use this feature to enable or disable Intel Speed Select Technology Performance Profile (SST-PP). The options are Disable and Enable.
Intel SST-PP
Use this feature to select the base frequency conditions for SST-PP. The options are Base, Config 3, and Config 4.
Activate SST-BF
Use this feature to enable or disable Intel Speed Select Technology Base Frequency. The options are Disable and Enable.
*If the feature above is set to Enable, the next feature is available for configuration:
Configure SST-BF
Enable this feature for the BIOS to configure the SST-BF High Priority Cores so the software does not configure it. The options are Disable and Enable.
EIST PSD Funtion
This feature allows you to choose between Hardware and Software to control the processor's frequency and performance (P-state). In HW_ALL mode, the processor hardware is responsible for coordinating the P-state, and the OS is responsible for keeping the P-state request up to date on all Logical Processors. In SW_ALL mode, the OS Power Manager is responsible for coordinating the P-state, and must initiate the transition on all Logical Processors. In SW_ANY mode, the OS Power Manager is responsible for coordinating the P-state and may initiate the transition on any Logical Processors. The options are HW_ALL and SW_ALL.
Turbo Mode
This feature enables dynamic control of the processor, allowing it to run above stock frequency. The options are Disable and Enable.
CPU Flex Ratio Override
Use this feature to enable or disable CPU Flex Ratio Prgoramming. The options are Disable and Enable.
If the feature above is set to Enable, the next feature is available for configuration:
CPU Core Flex Ratio
Use this feature to set the non-turbo mode processor core ratio multiplier. The default value is 23.
▶Hardware PM State Control
Hardware P-States
This setting allows you to select between OS and hardware-controlled P-states. Selecting Native Mode allows the OS to choose a P-state. Selecting Out of Band Mode allows the hardware to autonomously choose a P-state without OS guidance. Selecting Native Mode with No Legacy Support functions as Native Mode with no support for older hardware. The options are Disable, Native Mode, Out of Band Mode, and Native Mode with No Legacy Support.
▶ Frequency Prioritization
RAPL Prioritization
Use this feature to enable the RAPL balancer. The options are Enable and Disable.
▶CPU C State Control
Enable Monitor MWAIT
Select Enabled to enable the Monitor/Mwait instructions. The Monitor instructions monitors a region of memory for writes, and MWait instructions instruct the CPU to stop until the monitored region begins to write. The options are Disable and Enable.
CPU C6 Report
Select Enable to allow the BIOS to report the CPU C6 State (ACPI C3) to the operating system. During the CPU C6 State, the power to all cache is turned off. The options are Disable, Enable, and Auto.
Enhanced Halt State (C1E)
Select Enable to use Enhanced Halt State technology, which significantly reduces the CPU's power consumption by reducing its clock cycle and voltage during a Halt-state. The options are Disable and Enable.
▶Package C State Control
Package C State
This feature allows you to set the limit on the C State package register. The options are C0/C1 state, C2 state, C6(non Retention) state, and Auto.
▶CPU T State Control
Software Controlled T-States
Use this feature to enable Software Controlled T-States. The options are Disable and Enable.
If the feature above is set to Enable, the next feature is available for configuration:
T-State Throttle Level
Use this feature to enable or disable CPU throttling, which reduces power consumption. The options are Disable, 6.25%, 12.5%, 18.75%, 25.0%, 31.25%, 37.5%, 43.75%, 50.0%, 56.25%, 62.5%, 68.75%, 75.0%, 81.25%, 87.5%, and 93.75%.
▶Chipset Configuration
Warning: Setting the wrong values in the following features may cause the system to malfunction.
▶ North Bridge
▶Uncore Configuration
Uncore Configuration
• Number of CPU
• Number of IIO
• Current UPI Link Speed
• Current UPI Link Frequency
• Global MMIO Low Base / Limit
• Global MMIO High Base / Limit
• PCI-e Configuration Base / Size
Degrade Precedence
Use this feature to set degrade precedence when system settings are in conflict. Select Topology Precedence to degrade Features. Select Feature Precedence to degrade Topology. The options are Topology Precedence and Feature Precedence.
Link L0p Enable
Select Enable for the QPI to enter the L0p state for power saving. The options are Disable, Enable, and Auto.
Link L1 Enable
Select Enable for the QPI to enter the L1 state for power saving. The options are Disable, Enable, and Auto.
XPT Remote Prefetch
Use this feature to enable or disable Extended Prediction Table (XPT) Remote Prefetch. The options are Disable, Enable, and Auto.
KTI Prefetch
If this feature is enabled, the KTI Prefetcher preloads the L1 cache with data deemed relevant to allow the memory read to start earlier on a DDR bus in an effort to reduce latency. The options are Disable, Enable, and Auto.
Local/Remote Threshold
Use this feature to set the threshold for the IRQ signals that handle hardware interruptions. The options are Dsiable, Auto, Low, Medium, and High.
IO Directory Cache (IODC)
IO Directory Cache is an 8-entry cache that stores the directory state of remote IIO writes and memory lookups, and saves directory updates. Use this feature to lower cache to cache (C2C) transfer latencies. The options are Disable, Auto, Enable for Remote InvItoM Hybrid Push, InvItoM AllocFlow, Enable for Remote InvItoM Hybrid AllocNonAlloc, and Enable for Remote InvItoM and Remote WViLF.
SNC (Sub NUMA)
Use this feature to enable or disable Sub NUMA Clustering. Disable this feature to support 1-cluster and enable to support 2-clusters. The options are Disable and Enable SNC2 (2-clusters)
XPT Prefetch
Use this feature to enable or disable XPT Prefetch support, which allows an LLC request to be duplicated and sent to an appropriate memory controller based on the recent LLC history to reduce latency. The options are Disable, Enable, and Auto.
Snoop Throttle Configuration
Use this feature to select the level of snoop throttle setting. The options are Disabled, Low, Medium, High, and Auto.
PCIe Remote P2P Relaxed Ordering
Enable peer-to-peer relaxed ordering to optimize system performance. The options are Disable and Enable.
Stale AtoS
Use this feature to enable or disable Stale A to S optimization. There are three states in the in-memory directory: invalid (I), snoopAll (A), and shared (S). Data in the I state is clean and does not exist in other sockets. Data in the A state may exist in another exclusive or modified socket. Data in the S state is clean and may be shared across one or more sockets. The options are Disable, Enable, and Auto.
LLC Dead Line Alloc
Select Enable to opportunistically fill dead lines in the LLC. Select Disable to never fill dead lines in LLC. The options are Disable, Enable, and Auto.
▶ Memory Configuration
STEP DRAM Test
Use this feature to enable or disable the Samsung TestBIOS Enhanced PPR (STEP) function. The options are Enable and Disable.
If the feature above is set to Enable, the next feature is available for configuration:
Operation Mode
Select the test mode for STEP DRAM. The options are Test Only and Test and Repair.
Enforce POR
Select POR (Plan of Record) to enforce POR restrictions on DDR4 frequency and voltage programming. The options are POR and Disable.
PPR Type
Use this feature to select the Post Package Repair (PPR) type. The options are PPR Disabled, Hard PPR, and Soft PPR.
Memory Frequency
Use this feature to set the maximum memory frequency for onboard memory modules. The options are Auto, 2133, 2200, 2400, 2600, 2666, 2800, 2933, 3000, and 3200.
Data Scrambling for DDR4
Use this feature to enable or disable data scrambling for DDR4 memory. The options are Disable and Enable.
2x Refresh Enable
Use this feature to enable 2x memory refresh support to enhance memory performance. The options are Auto, Disable, and Enable.
▶ Memory Topology
This feature displays the information of memory modules detected by the BIOS.
▶ Memory RAS Configuration Setup
Enabled Pcode WA for SAI PG
Use this feature to enable Pcode Work Around for SAI Policy group for A Step. The options are Disabled and Enabled.
Mirror Mode
This feature allows memory to be mirrored between two channels, providing 100% redundancy. The options are Disable, Full Mirror Mode, and Partial Mirror Mode.
UEFI ARM Mirror
This feature allows the system to imitate the behavior of the UEFI based Address Range Mirror with setup option. The options are Disabled and Enabled.
Correctable Error Threshold
Use this feature to specify the threshold value for correctable memory-error logging, which sets a limit on the maximum number of events that can be logged in the memory error log at a given time. The default setting is 512.
Partial Cache Line Sparing PCLS
Use this feature to enable or disable Partial Cache Line Sparing (PCLS). The options are Disabled and Enabled.
ADDDC Sparing
Adaptive Double Device Data Correction (ADDDC) Sparing detects when the predetermined threshold for correctable errors is reached, copying the contents of the failing DIMM to spare memory. The failing DIMM or memory rank is disabled. The options are Disabled and Enabled.
Patrol Scrub
Patrol Scrubbing is a process that allows the CPU to correct correctable memory errors detected on a memory module and send the correction to the requestor (the original source). When this item is set to Enable, the IO hub reads and writes back one cache line every 16K cycles if there is no delay caused by internal processing. By using this method, roughly 64 GB of memory behind the IO hub is scrubbed every day. The options are Disabled, Enabled, and Enable at End of POST.
▶ IIO Configuration
▶CPU Configuration
IOU0/1/3/4 (IIO PCIe Port 1/2/4/5)
Use this feature to configure the PCIe port Bifuraction setting for PCIe port. The options are Auto, x4x4x4x4, x4x4x8, x8x4x4, x8x8, and x16.
▶CPU SLOT7 PCI-E 4.0 x8
▶CPU SLOT6 PCI-E 4.0 x16
▶CPU SLOT4 PCI-E 4.0 x16
JSLIM1 NVME0
JSLIM1 NVME0_1
JSLIM2 NVME1
JSLIM2 NVME1_1
Link Speed
Use this feature to select the link speed for the PCIe port. The options are Auto, Gen 1 (2.5 GT/s), Gen 2 (5 GT/s), Gen 3 (8 GT/s), and Gen 4 (16 GT/s).
The following information is displayed:
• PCI-E Port Link Status
• PCI-E Port Link Max
- PCI-E Port Link Speed
PCI-E Port Max Payload Size
Selecting Auto for this feature enables the motherboard to automatically detect the maximum Transaction Layer Packet (TLP) size for the connected PCIe device, allowing for maximum I/O efficiency. Selecting 128B or 256B designates maximum packet size of 128 or 256. The options are 128B, 256B, 512B, and Auto.
▶ IOAT Configuration
Disable TPH
Transparent Huge Pages (TPH) is a Linux memory management system that enables communication in larger blocks (pages). Enabling this feature increases performance. The options are No and Yes.
*If the feature above is set to No, the feature below is available for configuration:
Prioritize TPH
Use this feature to enable Prioritize TPH support. The options are Enable and Disable.
Relaxed Ordering
Select Yes to enable Relaxed Ordering support, which allows certain transactions to violate the strict-ordering rules of PCI bus for a transaction to be completed prior to other transactions that have already been enqueued. The options are No and Yes.
Intel(R) for Directed I/O (VT-d)
Intel® VT for Directed I/O (VT-d)
Select Enable to use Intel Virtualization Technology for Direct I/O VT-d support by reporting the I/O device assignments to the Virtual Machine Monitor (VMM) through the DMAR ACPI tables. This feature offers fully-protected I/O resource sharing across Intel platforms, providing greater reliability, security and availability in networking and data sharing. The options are Enable and Disable.
ACS Control
Select Enable to program Access Control Services (ACS) to the chipset PCIe root port bridge. Select No to program ACS to all PCIe root port bridges. The options are Enable and Disable.
Interrupt Remapping
Use this feature to enable Interrupt Remapping support, which detects and controls external interrupt requests. The options are Auto, Enable, and Disable.
Intel(R) VMD Technology
Intel(R) VMD Technology
Intel® VMD Technology
NVMe Mode Switch
Use this feature to select the NVMe mode. The options are Manual, VMD, and Auto.
*If the feature above is set to Manual, the following features are available for configuration:
Intel(R) VMD Technology
VMD Config for PCH ports
Enable/Disable VMD
Use this feature to enable or disable the volume management device for this stack. The options are Disable and Enable.
*If the feature above is set to Enable, the following feature is available for configuration:
M.2-H VMD
Use this feature to enable or disable hot plug for this port. The options are Disable and Enable.
VMD Config for IOU 0
Enable/Disable VMD
Use this feature to enable or disable the volume management device for this stack. The options are Disable and Enable.
If the feature above is set to Enable, the following features is available for configuration:
CPU SLOT7 PCI-E 4.0 x8 VMD
Use this feature to enable or disable VMD technology for this port. The options are Disable and Enable.
Hot Plug Capable
Use this feature to enable or disable hot plug for this port. The options are Disable and Enable.
VMD Config for IOU 1
Enable/Disable VMD
Use this feature to enable or disable the volume management device for this stack. The options are Disable and Enable.
*If the feature above is set to Enable, the following features is available for configuration:
CPU SLOT6 PCI-E 4.0 x16 VMD
Use this feature to enable or disable VMD technology for this port. The options are Disable and Enable.
Hot Plug Capable
Use this feature to enable or disable hot plug for this port. The options are Disable and Enable.
VMD Config for IOU 3
Enable/Disable VMD
Use this feature to enable or disable the volume management device for this stack. The options are Disable and Enable.
If the feature above is set to Enable, the following features are available for configuration:
CPU SLOT4 PCI-E 4.0 x16 VMD
Use this feature to enable or disable VMD technology for this port. The options are Disable and Enable.
CPU SLOT1 PCI-E 4.0 X8 VMD
Use this feature to enable or disable VMD technology for this port. The options are Disable and Enable.
Hot Plug Capable
Use this feature to enable or disable hot plug for this port. The options are Disable and Enable.
VMD Config for IOU 4
Enable/Disable VMD
Use this feature to enable or disable the volume management device for this stack. The options are Disable and Enable.
If the feature above is set to Enable, the following features are available for configuration:
JSLIM1 NVME0 VMD
Use this feature to enable or disable volume management device for this port. The options are Disable and Enable.
JSLIM1 NVME0\_1 VMD
Use this feature to enable or disable volume management device for this port. The options are Disable and Enable.
JSLIM1 NVME1 VMD
Use this feature to enable or disable volume management device for this port. The options are Disable and Enable.
JSLIM1 NVME1\_1 VMD
Use this feature to enable or disable volume management device for this port. The options are Disable and Enable.
Hot Plug Capable
Use this feature to enable or disable hot plug for this port. The options are Disable and Enable.
PCI-E ASPM Support (Global)
Use this feature to enable or disable ASPM support for all donwstream devices. The options are Disable and Auto.
IIO eDPC Support
Use this feature to enable or disable IIO enhanced DPC support. The options are Disable, On Fatal Error, and On Fatal and Non-Fatal Errors.
*If the feature above is set to On Fatal Error or On Fatal and Non-Fatal Errors, the next two features are available for configuration:
IIO eDPC Interrupt
Use this feature to enable or disable IIO enhanced DPC interrupt. The options are Disable and Enable.
IIO eDPC ERR\_COR Message
Use this feature to enable or disable IIO enhanced DPC error correction message. The options are Disable and Enable.
South Bridge
The following USB information is displayed:
- USB Module Version
- USB Devices
Legacy USB Support
This feature enables support for USB 2.0 and older. The options are Enabled, Disabled, and Auto.
XHCI Hand-off
When this feature is disabled, the motherboard will not support USB 3.0. The options are Enabled and Disabled.
Port 60/64 Emulation
This feature allows legacy I/O support for USB devices like mice and keyboards. The options are Disabled and Enabled.
PCIe PLL SSC
Use this feature to enable or disable PCIe PLL SSC. The options are Disabled and Enabled.
Port 61h Bit-4 Emulation
Select Enabled to enable the emulation of Port 61h bit-4 toggling in System Management Mode (SMM). The options are Disabled and Enabled.
▶Server ME Information
The following General ME Configuration is displayed:
- General ME Configuration
• Oper. Firmware Version
• Backup Firmware Version
• Recovery Firmware Version
• ME Firmware Status #1
• ME Firmware Status #2 - Current State
- Error Code
▶PCH SATA Configuration
SATA Controller
This feature enables or disables the onboard SATA controller supported by the Intel PCH chip. The options are Disable and Enable.
Configure SATA as
Select AHCI to configure an sSATA drive specified as an AHCI drive. Select RAID to configure an sSATA drive specified as a RAID drive. The options are AHCI and RAID.
*If the feature above is set to RAID, SATA RSTe Boot Info and SATA RAID Option ROM/UEFI Driver are available for configuration:
SATA RSTe Boot Info
Select Enable to provide full int13h support for the devices attached to sSATA controller. The options are Disable and Enable.
Support Aggressive Link Power Management
When this feature is set to Enable, the SATA AHCI controller manages the power usage of the SATA link. The controller puts the link in a low power mode during extended periods of I/O inactivity, and returns the link to an active state when I/O activity resumes. The options are Disable and Enable.
SATA RAID Option ROM/UEFI Driver
Select UEFI to load the EFI driver for system boot. Select Legacy to load a legacy driver for system boot. The options are Disable, EFI, and Legacy.
SATA Port 0-7
This feature displays the information detected on the installed SATA drive on the particular SATA port.
- Software Preserve Support
SATA Port 0-7 Hot Plug
Set this feature to Enable for hot plug support, which allows you to replace a SATA drive without shutting down the system. The options are Disable and Enable.
SATA Port 0-7 Spin Up Device
Set this feature to enable or disable the PCH to initialize the device. The options are Disable and Enable.
SATA Port 0-7 SATA Device Type
Use this feature to specify if the SATA port specified should be connected to a Solid State Drive or a Hard Disk Drive. The options are Hard Disk Drive and Solid State Drive.
▶PCH sSATA Configuration
sSATA Controller
This feature enables or disables the onboard SATA controller supported by the Intel PCH chip. The options are Enable and Disable.
Configure sSATA as
Select AHCI to configure an sSATA drive specified as an AHCI drive. Select RAID to configure an sSATA drive specified as a RAID drive. The options are AHCI and RAID.
*If the feature above is set to RAID, the sSATA RSTe Boot Info and sSATA RAID Option ROM/UEFI Driver are available for configuration:
sSATA RSTe Boot Info
Select Enable to provide full int13h support for the devices attached to sSATA controller. The options are Disable and Enable.
Support Aggressive Link Power Management
When this feature is set to Enable, the SATA AHCI controller manages the power usage of the SATA link. The controller puts the link in a low power mode during extended periods of I/O inactivity, and returns the link to an active state when I/O activity resumes. The options are Disable and Enable.
sSATA RAID Option ROM/UEFI Driver
Select UEFI to load the EFI driver for system boot. Select Legacy to load a legacy driver for system boot. The options are Disable, EFI, and Legacy.
sSATA Port 0/1/2
This feature displays the information detected on the installed SATA drive on the particular SATA port.
- Software Preserve Support
sSATA Port 0/1/2 Hot Plug
Set this feature to Enable for hot plug support, which allows you to replace a SATA drive without shutting down the system. The options are Disabled and Enabled.
sSATA Port 0/1/2 Spin Up Device
Set this feature to enable or disable the PCH to initialize the device. The options are Disabled and Enabled.
sSATA Port 0/1/2 SATA Device Type
Use this feature to specify if the SATA port specified should be connected to a Solid State Drive or a Hard Disk Drive. The options are Hard Disk Drive and Solid State Drive.
▶Network Configuration
Network Stack
Select Enabled to enable PXE (Preboot Execution Environment) or UEFI (Unified Extensible Firmware Interface) for network stack support. The options are Disabled and Enabled.
IPv4 PXE Support
Select Enabled to enable IPv4 PXE boot support. The options are Disabled and Enabled.
IPv4 HTTP Support
Select Enabled to enable IPv4 HTTP boot support. The options are Disabled and Enabled.
IPv6 PXE Support
Select Enabled to enable IPv6 PXE boot support. The options are Disabled and Enabled.
IPv6 HTTP Support
Select Enabled to enable IPv6 HTTP boot support. The options are Disabled and Enabled.
PXE Boot Wait Time
Use this option to specify the wait time to press the ESC key to abort the PXE boot. Press "+" or "-" on your keyboard to change the value. The default setting is 0.
Media Detect Count
Use this option to specify the number of times media is checked. Press "+" or "-" on your keyboard to change the value. The default setting is 1.
▶MAC:xxxxxxxxxxxx-IPv6 Network Configuration
▶MAC:xxxxxxxxxxxx-IPv6 Network Configuration
▶MAC:xxxxxxxxxxxx-IPv6 Network Configuration
▶MAC:xxxxxxxxxxxx-IPv6 Network Configuration
▶MAC:xxxxxxxxxxxx-IPv6 Network Configuration
▶MAC:xxxxxxxxxxxx-IPv6 Network Configuration
▶ Enter Configuration Menu
Interface Name
Interface Type
MAC Address
Host addresses
Route Table
Gateway addresses
DNS addresses
Interface ID
Use this feature to set the 64-bit alternative interface ID for the device.
DAD Transmit Count
If this set feature is set to 0, the Duplication Address Detection is not performed. Set the value to a preferred selection.
Policy
Use this feature to set the policy to automatic or manual. The options or automatic and manual.
Save Changes and Exit
Select this feature to save the changes for the features above and exit.
▶MAC:xxxxxxxxxxxx-IPv4 Network Configuration
▶MAC:xxxxxxxxxxxx-IPv4 Network Configuration
▶MAC:xxxxxxxxxxxx-IPv4 Network Configuration
▶MAC:xxxxxxxxxxxx-IPv4 Network Configuration
▶MAC:xxxxxxxxxxxx-IPv4 Network Configuration
▶MAC:xxxxxxxxxxxx-IPv4 Network Configuration
Configured
Use this feature to indicate whether the network address is configured successfully or not. The options or Disabled and Enabled.
Save Changes and Exit
Select this feature to save the changes for the features above and exit.
▶KMIP Server Configuration
KMIP Server IP address
Enter the IP4 address in dotted-decimal notation (e.g., 255.255.255.255).
KMIP TCP Port number
Enter the KMIP TCP port number (from 100 to 9999) The default is 5696.
TimeZone
Use this feature to select the current time zone.
TCG Nvme KMS Policy
Use this feature to select the Trusted Computing Group (TCG) NVMe KMS policy. The options are Normal Unlock, Do Nothing, Reset All Devices Deleted Key Id List.
TCG Nvme KMS Status Retry Time
Use this feature to select the number of attempts of test connections to the Key Management Server. The options are 0 - 300 seconds and the default is 60.
Client UserName
Press Enter to create a client username.
Client Password
Press Enter to create a client username password.
KMS TLS Certificate
▶CA Certificate
Use this feature to enroll factory defaults or load the CA certificates from a file. The options are Update, Delete, and Export.
▶Client Certificate
Use this feature to enroll factory defaults or load the client certificates from a file. The options are Update, Delete, and Export.
▶Client Private Key
Use this feature to enroll factory defaults or load the client private key from a file. The options are Update, Delete, and Export.
▶ PCIe/PCI/PnP Configuration
PCI Bus Driver Version
PCI Devices Common Settings:
Above 4G Decoding (Available if the system supports 64-bit PCI decoding)
Select Enabled to decode a PCI device that supports 64-bit in the space above 4G Address.
The options are Disabled and Enabled.
SR-IOV Support
Use this feature to enable or disable Single Root IO Virtualization Support. The options are Disabled and Enabled.
ARI Support
Use this feature to enable or disable ARI support. The options are Disabled and Enabled.
Bus Master Enable
Use this feature to enable the Bus Master, which enables the Bus Master Attribute for DMA transaction. The options are Disabled and Enabled.
Consistent Device Name Support
Use this feature to enable ACPI_DSM device name support for onboard devices and slots. The options are Disabled and Enabled.
MMIO High Base
Use this feature to select the base memory size according to memory-address mapping for the IO hub. The options are 56T, 40T, 32T, 24T, 16T, 4T, 2T, 1T, and 512 G.
MMIO High Granularity Size
Use this feature to select the high memory size according to memory-address mapping for the IO hub. The options are 1G, 4G, 16G, 64G, 256G, and 1024G.
Maximum Read Request
Use this item to select the Maximum Read Request size of the PCIe device, or select Auto to allow the System BIOS to determine the value. The options are Auto, 128 Bytes, 256 Bytes, 512 Bytes, 1024 Bytes, 2048 Bytes, and 4096 Bytes.
MMCFG Base
Use this feature to select the low base address for PCIe adapters to increase base memory. The options are 1G, 1.5G, 1.75G, 2G, 2.25G, 3G, and Auto.
NVMe Firmware Source
The feature determines which type of NVMe firmware should be used in your system. The options are Vendor Defined Firmware and AMI Native Support.
VGA Priority
Use this feature to select VGA priority when multiple VGA devices are detected. Select Onboard to give priority to your onboard video device. Select Offboard to give priority to your graphics card. The options are Onboard and Offboard.
Onboard Video Option ROM
Use this feature to select which firmware function to be loaded for LAN1 used for system boot. The options are Disabled and Legacy (if the Boot Mode Select feature under the Boot tab is set to Legacy), Disabled and EFI (if the Boot Mode Select feature under the Boot tab is set to UEFI), and Disabled, Legacy, and EFI (if the Boot Mode Select feature under the Boot tab is set to Dual).
CPU SLOT4 PCI-E 4.0 X16 OPROM
Use this feature to select which firmware type to be loaded for the add-on card in this slot. The options are Disabled and Legacy (if the Boot Mode Select feature under the Boot tab is set to Legacy), Disabled and EFI (if the Boot Mode Select feature under the Boot tab is set to UEFI), and Disabled, Legacy, and EFI (if the Boot Mode Select feature under the Boot tab is set to Dual).
CPU SLOT6 PCI-E 4.0 X16 OPROM
Use this feature to select which firmware type to be loaded for the add-on card in this slot. The options are Disabled and Legacy (if the Boot Mode Select feature under the Boot tab is set to Legacy), Disabled and EFI (if the Boot Mode Select feature under the Boot tab is set to UEFI), and Disabled, Legacy, and EFI (if the Boot Mode Select feature under the Boot tab is set to Dual).
CPU SLOT7 PCI-E 4.0 X8 OPROM
Use this feature to select which firmware type to be loaded for the add-on card in this slot. The options are Disabled and Legacy (if the Boot Mode Select feature under the Boot tab is set to Legacy), Disabled and EFI (if the Boot Mode Select feature under the Boot tab is set to UEFI), and Disabled, Legacy, and EFI (if the Boot Mode Select feature under the Boot tab is set to Dual).
CPU SLOT6 PCI-E 4.0 X16 OPROM
Use this feature to select which firmware type to be loaded for the add-on card in this slot. The options are Disabled and Legacy (if the Boot Mode Select feature under the Boot tab is set to Legacy), Disabled and EFI (if the Boot Mode Select feature under the Boot tab is set to UEFI), and Disabled, Legacy, and EFI (if the Boot Mode Select feature under the Boot tab is set to Dual).
CPU SLOT7 PCI-E 4.0 X8 OPROM
Use this feature to select which firmware type to be loaded for the add-on card in this slot. The options are Disabled and Legacy (if the Boot Mode Select feature under the Boot tab is set to Legacy), Disabled and EFI (if the Boot Mode Select feature under the Boot tab is set to UEFI), and Disabled, Legacy, and EFI (if the Boot Mode Select feature under the Boot tab is set to Dual).
M.2-H OPROM
Use this feature to select which firmware type to be loaded for the add-on card in this slot. The options are Disabled and Legacy (if the Boot Mode Select feature under the Boot tab is set to Legacy), Disabled and EFI (if the Boot Mode Select feature under the Boot tab is set to UEFI), and Disabled, Legacy, and EFI (if the Boot Mode Select feature under the Boot tab is set to Dual).
Onboard LAN1 Option ROM
Use this feature to select a desired firmware function to be loaded for onboard LAN1. The options are Disabled and Legacy (if the Boot Mode Select feature under the Boot tab is set to Legacy), Disabled and EFI (if the Boot Mode Select feature under the Boot tab is set to UEFI), and Disabled, Legacy, and EFI (if the Boot Mode Select feature under the Boot tab is set to Dual).
Onboard LAN3 Option ROM
Use this feature to select a desired firmware function to be loaded for onboard LAN3. The options are Disabled and Legacy (if the Boot Mode Select feature under the Boot tab is set to Legacy), Disabled and EFI (if the Boot Mode Select feature under the Boot tab is set to UEFI), and Disabled, Legacy, and EFI (if the Boot Mode Select feature under the Boot tab is set to Dual).
JNVME0 NVME0/ JNVME0 NVME1/ JNVME1 NVME2/ JNVME1 NVME3 Option ROM
Use this feature to select a desired firmware function to be loaded for onboard NVMe1 - NVMe2. The options are Disabled and Legacy (if the Boot Mode Select feature under the Boot tab is set to Legacy), Disabled and EFI (if the Boot Mode Select feature under the Boot tab is set to UEFI), and Disabled, Legacy, and EFI (if the Boot Mode Select feature under the Boot tab is set to Dual).
▶Super IO Configuration
The following Super IO information is displayed:
• Super IO Chip AST2600
▶ Serial Port 1 Configuration
This submenu allows you to configure the settings of Serial Port 1.
Serial Port 1
Select Enabled to enable the selected onboard serial port. The options are Disabled and Enabled.
Device Settings
This feature displays the status of the serial port.
Change Settings
This feature specifies the base I/O port address and the Interrupt Request address of the serial port. Select Auto to allow the BIOS to automatically assign the base I/O and IRQ address. The options are Auto, (IO=3F8h; IRQ=4,), (IO=2F8h; IRQ=4,), (IO=3E8h; IRQ=4,), and (IO=2E8h; IRQ=4).
▶SOL Configuration
This submenu allows you to configure the settings of Serial Port 2.
Serial Port 2
Select Enabled to enable the selected onboard serial port. The options are Disabled and Enabled.
Device Settings
This feature displays the status of a serial port.
Change Settings
This feature specifies the base I/O port address and the Interrupt Request address of the serial port. Select Auto to allow the BIOS to automatically assign the base I/O and IRQ address. The options are Auto, (IO=3F8h; IRQ=3;), (IO=2F8h; IRQ=3;), (IO=3E8h; IRQ=3;), and (IO=2E8h; IRQ=3;).
Serial Port 2 Attribute (Available for Serial Port 2 only)
Select SOL to use COM Port 2 as a Serial Over LAN (SOL) port for console redirection. The options are SOL and COM.
▶ Serial Port Console Configuration
COM1 Console Redirection
Select Enabled to enable console redirection support for the serial port. The options are Enabled and Disabled.
*If the feature above is set to Enabled, the following features are available for configuration:
▶COM1 Console Redirection Settings
Use this feature to specify how the host computer exchanges data with the client computer, which is the remote computer used by the user.
Terminal Type
This feature allows you to select the target terminal emulation type for Console Redirection. Select VT100 to use the ASCII Character set. Select VT100+ to add color and function key support. Select ANSI to use the Extended ASCII Character Set. Select VT-UTF8 to use UTF8 encoding to map Unicode characters into one or more bytes. The options are VT100, VT100+, VT-UTF8, and ANSI.
Bits Per Second
Use this feature to set the transmission speed for a serial port used in Console Redirection. Make sure that the same speed is used in the host computer and the client computer. A lower transmission speed may be required for long and busy lines. The options are 9600, 19200, 38400, 57600 and 115200 (bits per second).
Data Bits
Use this feature to set the data transmission size for Console Redirection. The options are 7 Bits and 8 Bits.
Parity
A parity bit can be sent along with regular data bits to detect data transmission errors. Select Even if the parity bit is set to 0, and the number of 1's in data bits is even. Select Odd if the parity bit is set to 0, and the number of 1's in data bits is odd. Select None if you do not want to send a parity bit with your data bits in transmission. Select Mark to add a mark as a parity bit to be sent along with the data bits. Select Space to add a Space as a parity bit to be sent with your data bits. The options are None, Even, Odd, Mark, and Space.
Stop Bits
A stop bit indicates the end of a serial data packet. Select 1 Stop Bit for standard serial data communication. Select 2 Stop Bits if slower devices are used. The options are 1 and 2.
Flow Control
Use this feature to set the flow control for Console Redirection to prevent data loss caused by buffer overflow. Send a "Stop" signal to stop sending data when the receiving buffer is full. Send a "Start" signal to start sending data when the receiving buffer is empty. The options are None and Hardware RTS/CTS.
VT-UTF8 Combo Key Support
Select Enabled to enable VT-UTF8 Combination Key support for ANSI/VT100 terminals. The options are Disabled and Enabled.
Recorder Mode
Select Enabled to capture the data displayed on a terminal and send it as text messages to a remote server. The options are Disabled and Enabled.
Resolution 100x31
Select Enabled for extended-terminal resolution support. The options are Disabled and Enabled.
Legacy OS Redirection Resolution
Use this feature to select the number of rows and columns used in Console Redirection for legacy OS support. The options are 80x24 and 80x25.
Putty KeyPad
This feature selects the settings for Function Keys and KeyPad used for Putty, which is a terminal emulator designed for the Windows OS. The options are VT100, LINUX, XTERMR6, SC0, ESCN, and VT400.
Redirection After BIOS POST
Use this feature to enable or disable legacy console redirection after BIOS POST. When set to Bootloader, legacy console redirection is disabled before booting the OS. When set to Always Enable, legacy console redirection remains enabled when booting the OS. The options are Always Enable and Bootloader.
SOL Console Redirection
Select Enabled to use the SOL port for Console Redirection. The options are Disabled and Enabled.
*If the feature above is set to Enabled, the following features are available for configuration:
▶SOL Console Redirection Settings
Use this feature to specify how the host computer exchanges data with the client computer, which is the remote computer used by the user.
Terminal Type
Use this feature to select the target terminal emulation type for Console Redirection. Select VT100 to use the ASCII Character set. Select VT100+ to add color and function key support. Select ANSI to use the Extended ASCII Character Set. Select VT-UTF8 to use UTF8 encoding to map Unicode characters into one or more bytes. The options are ANSI, VT100, VT100+, and VT-UTF8.
Bits Per Second
Use this feature to set the transmission speed for a serial port used in Console Redirection. Make sure that the same speed is used in the host computer and the client computer. A lower transmission speed may be required for long and busy lines. The options are 9600, 19200, 38400, 57600, and 115200 (bits per second).
Data Bits
Use this feature to set the data transmission size for Console Redirection. The options are 7 Bits and 8 Bits.
Parity
A parity bit can be sent along with regular data bits to detect data transmission errors. Select Even if the parity bit is set to 0, and the number of 1's in data bits is even. Select Odd if the parity bit is set to 0, and the number of 1's in data bits is odd. Select None if you do not want to send a parity bit with your data bits in transmission. Select Mark to add a mark as a parity bit to be sent along with the data bits. Select Space to add a Space as a parity bit to be sent with your data bits. The options are None, Even, Odd, Mark and Space.
Stop Bits
A stop bit indicates the end of a serial data packet. Select 1 Stop Bit for standard serial data communication. Select 2 Stop Bits if slower devices are used. The options are 1 and 2.
Flow Control
Use this feature to set the flow control for Console Redirection to prevent data loss caused by buffer overflow. Send a "Stop" signal to stop sending data when the receiving buffer is full. Send a "Start" signal to start sending data when the receiving buffer is empty. The options are None and Hardware RTS/CTS.
VT-UTF8 Combo Key Support
Select Enabled to enable VT-UTF8 Combination Key support for ANSI/VT100 terminals. The options are Disabled and Enabled.
Recorder Mode
Select Enabled to capture the data displayed on a terminal and send it as text messages to a remote server. The options are Disabled and Enabled.
Resolution 100x31
Select Enabled for extended-terminal resolution support. The options are Disabled and Enabled.
Legacy OS Redirection Resolution
Use this feature to select the number of rows and columns used in Console Redirection for legacy OS support. The options are 80x24 and 80x25.
Putty KeyPad
This feature selects Function Keys and KeyPad settings for Putty, which is a terminal emulator designed for the Windows OS. The options are VT100, LINUX, XTERMR6, SCO, ESCN, and VT400.
Redirection After BIOS POST
Use this feature to enable or disable legacy Console Redirection after BIOS POST. When set to Bootloader, legacy Console Redirection is disabled before booting the OS. When set to Always Enable, legacy Console Redirection remains enabled when booting the OS. The options are Always Enable and Bootloader.
Legacy Console Redirection
Legacy Serial Redirection Port
Use this feature to select a COM port to display redirection of Legacy OS and Legacy OPROM messages. The options are COM1 and SOL.
EMS (Emergency Management Services) Console Redirection
Select Enabled to use a COM port selected by you for EMS Console Redirection. The options are Enabled and Disabled.
*If the feature above is set to Enabled, the following features are available for configuration:
▶EMS Console Redirection Settings
This feature allows you to specify how the host computer exchanges data with the client computer, which is the remote computer used by the user.
Out-of-Band Mgmt Port
The feature selects a serial port in a client server to be used by the Microsoft Windows Emergency Management Services (EMS) to communicate with a remote host server. The options are COM1 and SOL.
Terminal Type
Use this feature to select the target terminal emulation type for Console Redirection. Select VT100 to use the ASCII character set. Select VT100+ to add color and function key support. Select ANSI to use the extended ASCII character set. Select VT-UTF8 to use UTF8 encoding to map Unicode characters into one or more bytes. The options are VT100, VT100+, VT-UTF8, and ANSI.
Bits Per Second EMS
This feature sets the transmission speed for a serial port used in Console Redirection. Make sure that the same speed is used in the host computer and the client computer. A lower transmission speed may be required for long and busy lines. The options are 9600, 19200, 57600, and 115200 (bits per second).
Flow Control EMS
Use this feature to set the flow control for Console Redirection to prevent data loss caused by buffer overflow. Send a "Stop" signal to stop sending data when the receiving buffer is full. Send a "Start" signal to start sending data when the receiving buffer is empty. The options are None, Hardware RTS/CTS, and Software Xon/Xoff.
Data Bits EMS, Parity EMS, Stop Bits EMS
▶ACPI Settings
NUMA
Use this feature to enable or disable Non-Uniform Memory Access (NUMA), a feature that improves memory-to-processor communication and performance. The options are Disabled and Enabled.
UMA-Based Clustering
Use this feature to enable or disable Uniform Memory Access (UMA) clustering. The options are Disable (All2All) and Hemishpere (2-clusters).
WHEA Support
Select Enabled to support the Windows Hardware Error Architecture (WHEA) platform and provide a common infrastructure for the system to handle hardware errors within the Windows OS environment to reduce system crashes and to enhance system recovery and health monitoring. The options are Disabled and Enabled.
High Precision Event Timer
Select Enabled to activate the High Precision Event Timer (HPET) that produces periodic interrupts at a much higher frequency than a Real-time Clock (RTC) does in synchronizing multimedia streams, providing smooth playback and reducing the dependency on other timestamp calculation devices, such as an x86 RDTSC Instruction embedded in the CPU. The High Performance Event Timer is used to replace the 8254 Programmable Interval Timer. The options are Disabled and Enabled.
▶Trusted Computing
The motherboard supports TPM 2.0. The following Trusted Platform Module (TPM) information is displayed if a TPM 2.0 module is detected:
- Firmware Version
- Vendor Name
Security Device Support
If this feature and the TPM jumper on the motherboard are both set to Enabled, onboard security devices are enabled for Trusted Platform Module (TPM) support to enhance data integrity and network security. Reboot the system for a change on this setting to take effect.
The options are Disable and Enable.
• Active PCR Bank
• Available PCR banks
SHA-1 PCR Bank
Use this feature to disable or enable the SHA-1 Platform Configuration Register (PCR) bank for the installed TPM device. The options are Disabled and Enabled.
SHA256 PCR Bank
Use this feature to disable or enable the SHA256 Platform Configuration Register (PCR) bank for the installed TPM device. The options are Disabled and Enabled.
Pending Operation
Use this feature to schedule a TPM-related operation to be performed by a security device for system data integrity. Your system will reboot to carry out a pending TPM operation. The options are None and TPM Clear.
Platform Hierarchy
Use this feature to disable or enable platform hierarchy for platform protection. The options are Disabled and Enabled.
Storage Hierarchy
Use this feature to disable or enable storage hierarchy for cryptographic protection. The options are Disabled and Enabled.
Endorsement Hierarchy
Use this feature to disable or enable endorsement hierarchy for privacy control. The options are Disabled and Enabled.
PH Randomization
Use this feature to disable or enable Platform Hierarchy (PH) Randomization. The options are Disabled and Enabled.
SMCI BIOS-Based TPM Provision Support
Use this feature to enable the Supermicro TPM Provision support. The options are Disabled and Enabled.
TXT Support
Use this feature to enable or disable TXT Support. Intel Trusted Execution Technology (TXT) helps protect against software-based attacks and ensures protection, confidentiality, and integrity of data stored or created on the system. The options are Disabled and Enabled.
▶HTTP Boot Configuration
HTTP Boot Configuration
HTTP Boot Policy
Use this feature to select the boot policy. The options are Apply to all LANs, Apply to each LAN, and Boot Priority #1 instantly.
Priority of HTTP Boot:
Instance of Priority 1:
Use this feature to set the rank target port. The default value is 1.
Select IPv4 or IPv6
Use this feature to select which LAN port to boot from. The options are IPv4 and IPv6.
Boot Description
Highlight the feature and press enter to create a boot description. The description cannot be more than 75 characters.
Boot URI
Highlight the feature and press enter to create a boot URI.
Instance of Priority 2/3/4/5/6:
Use this feature to set the rank target port. The default value is 0.
▶iSCSI Configuration
▶Attempt Priority
Attempt Priority
Use this feature to set the attempt priorities. The options are Host Attempt, Redfish Attempt, and Rsd Attempt.
Commit Changes and Exit
Select this feature to save the changes and exit.
▶Host iSCSI Configuration
iSCSI Initiator Name
This feature allows you to enter the unique name of the iSCSI Initiator in IQN format. Once the name of the iSCSI Initiator is entered into the system, configure the proper settings for the following features.
▶ Add an Attempt
▶ Delete Attempts
▶ Change Attempt Order
Intel(R) Ethernet Controller X550 - xx:xx:xx:xx:xx:xx
Intel(R) Ethernet Controller X550 - xx:xx:xx:xx:xx:xx
Intel(R) I350 Gigabit Network Connection- xx:xx:xx:xx:xx:xx
Intel(R) 1350 Gigabit Network Connection- xx:xx:xx:xx:xx:xx
Intel(R) I350 Gigabit Network Connection- xx:xx:xx:xx:xx:xx
Intel(R) I350 Gigabit Network Connection- xx:xx:xx:xx:xx:xx
▶Firmware Image Properties
This submenu displays the firmware version.
Option ROM version
Unique NVM/EEPROM ID
NVM Version
▶NIC Configuration
Link Speed
Use this feature to specify the port speed used for the selected boot protocol. The options are Auto Negotiated, 10 Mbps Half, 10 Mbps Full, 100 Mbps Half, and 100 Mbps Full.
Wake On LAN
Select Enabled for wake on LAN support, which allows the system to wake up when an onboard LAN device receives an incoming signal. The options are Disabled and Enabled.
Blink LEDs
Use this feature to identify the physical network port by blinking the associated LED. Use the keyboard to select a value.
UEFI Driver
Adapter PBA
Device Name
Chip Type
PCI Device ID
PCI Address
Link Status
MAC Address
Virtual MAC Address
▶TLS Authenticate Configuration
This submenu allows you to configure Transport Layer Security (TLS) settings.
▶Server CA Configuration
▶Enroll Certification
Enroll Certification Using File
Use this feature to enroll certification from a file.
Certification GUID
Use this feature to input the certification GUID.
Commit Changes and Exit
Use this feature to save all changes and exit TLS settings.
Discard Changes and Exit
Use this feature to discard all changes and exit TLS settings.
▶ Delete Certification
Use this feature to delete certification.
Intel Virtual RAID on CPU
This submenu displays RAID volumes detected by the system.
▶All Intel VMD Controller
This submenu displays VMD controllers detected by the system.
▶Driver Health
This feature provides the health status for the network drivers and controllers, and all UEFI drivers detected by the system.
Intel(R) PRO/1000 9.3.10 PCI-E
Controller 5E19EA98 Child 0
Intel(R) I350 Gigabit Network Connection
Controller 5E1A5698 Child 0
Intel(R) I350 Gigabit Network Connection
Controller 5E1A5F98 Child 0
Intel(R) I350 Gigabit Network Connection
Controller 5E1A7E98 Child 0
Intel(R) I350 Gigabit Network Connection
Intel(R) 10GbE Driver 7.3.13 x64
Controller 5E19B618 Child 0
Intel(R) Ethernet Controller X550
Controller 5E19BF98 Child 0
Intel(R) Ethernet Controller X550
Intel(R) VROC with VMD Technology 7.5.0.1130
Controller 5E11FA98 Child 0
4.4 Event Logs
Use this menu to configure Event Log settings.

text_image
Aptio Setup - AMI Main Advanced Event Logs IFMI Security Boot Save & Exit Change SMBIOS Event Log Settings View SMBIOS Event Log Press▶Change SMBIOS Event Log Settings
Enabling/Disabling Options
SMBIOS Event Log
Change this feature to enable or disable all features of the SMBIOS Event Logging during system boot. The options are Disabled and Enabled.
Erasing Settings
Erase Event Log
If No is selected, data stored in the event log will not be erased. Select Yes, Next Reset, data in the event log will be erased upon next system reboot. Select Yes, Every Reset, data in the event log will be erased upon every system reboot. The options are No, Yes, Next reset, and Yes, Every reset.
When Log is Full
Select Erase Immediately for all messages to be automatically erased from the event log when the event log memory is full. The options are Do Nothing and Erase Immediately.
SMBIOS Event Log Standard Settings
Log System Boot Event
This option toggles the System Boot Event logging to enabled or disabled. The options are Disabled and Enabled.
MECI
The Multiple Event Count Increment (MECI) counter counts the number of occurrences that a duplicate event must happen before the MECI counter is incremented. This is a numeric value. The default value is 1.
METW
The Multiple Event Time Window (METW) defines the number of minutes that must pass between duplicate log events before MECI is incremented. This is in minutes, from 0 to 99. The default value is 60.

Note: After making changes on a setting, reboot the system for the changes to take effect.
▶View SMBIOS Event Log
Select this submenu and press enter to see the contents of the SMBIOS event log. The following categories is displayed: Date/Time/Error Codes/Severity.
4.5 IPMI
Use this menu to configure IPMI settings.

text_image
Aptio Setup - AMI Main Advanced Event Logs IFMI Security Boot Save & Exit EMC Firmware Revision 00.10.63 IPMI STATUS Working ► System Event Log ► EMC Network Configuration PressBMC Firmware Revision
This feature indicates the IPMI firmware revision used in your system.
IPMI STATUS (Baseboard Management Controller)
This feature indicates the status of the IPMI firmware installed in your system.
▶System Event Log
Enabling/Disabling Options
SEL Components
Select Enabled for all system event logging at bootup. The options are Disabled and Enabled.
Erasing Settings
Erase SEL
Select Yes, On next reset to erase all system event logs upon next system reboot. Select Yes, On every reset to erase all system event logs upon each system reboot. Select No to keep all system event logs after each system reboot. The options are No, Yes, On next reset, and Yes, On every reset.
When SEL is Full
This feature allows you to decide what the BIOS should do when the system event log is full. Select Erase Immediately to erase all events in the log when the system event log is full. The options are Do Nothing and Erase Immediately.

Note: After making changes on a setting, reboot the system for the changes to take effect.
▶BMC Network Configuration
BMC Network Configuration
Update IPMI LAN Configuration
Select Yes for the BIOS to implement all IP/MAC address changes at the next system boot. The options are No and Yes.
*If the feature above is set to Yes, Configuration Address Source, VLAN, and IPv6 Support are available for configuration:
Configure IPv4 Support
IPMI LAN Selection
IPMI Network Link Status
Configuration Address Source
This feature allows you to select the source of the IP address for this computer. If Static is selected, you need to know the IP address of this computer and enter it to the system manually in the field. If DHCP is selected, the BIOS searches for a Dynamic Host Configuration Protocol (DHCP) server in the network that is attached to and request the next available IP address for this computer. The options are DHCP and Static.
*If the feature above is set to Static, the following features are available for configuration:
Station IP Address
This features displays the Station IP address for this computer. The address can be manually entered. This should be in decimal and in dotted quad form (i.e., 192.168.10.253).
Subnet Mask
This feature displays the sub-network that this computer belongs to. The address can be manually entered. The value of each three-digit number separated by dots should not exceed 255.
Station MAC Address
Gateway IP Address
This feature displays the Gateway IP address for this computer. The address can be manually entered. This should be in decimal and in dotted quad form (i.e., 172.31.0.1).
VLAN
This feature displays the virtual LAN settings. The options are Disabled and Enabled.
VLAN ID
This feature is enabled if VLAN is enabled.
Configure IPv6 Support
IPv6 Address Status
IPv6 Support
Use this feature to enable IPv6 support. The options are Enabled and Disabled.
4.6 Security
Use this menu to configure the following security settings for the system.

text_image
Aptio Setup - AMI Main Advanced Event Logs IPMI Security Boot Save & Exit Administrator Password Not Installed User Password Not Installed Password Description If the Administrator's / User's password is set, then this only limits access to Setup and is asked for when entering Setup. Please set Administrator's password first in order to set User's password, if clear Administrator's password, the User's password will be cleared as well. The password length must be in the following range: Minimum length 3 Maximum length 20 Administrator Password Password Check [Setup] Hard Drive Security Frozen [Enabled] SMCI Security Erase Configuration Lockdown Mode [Disabled] Set Administrator Password +: Select Screen ↑↓: Select Item Enter: Select +/-: Change Opt. F1: General Help F2: Previous Values F3: Optimized Defaults F4: Save & Exit ESC: Exit Version 2.21.1278 Copyright (C) 2020 AMIAdministrator Password
Press Enter to create a new, or change an existing, Administrator password.
Password Check
Select Setup for the system to check for a password at Setup. Select Always for the system to check for a password at boot up or upon entering the BIOS Setup utility. The options are Setup and Always.
Hard Drive Security Frozen
Use this feature to enable or disable the BIOS security frozen command for SATA and NVMe devices. The options are Enabled and Disabled.
▶SMCI Security Erase Configuration
This section displays information if a storage device is detected by the system.
- HDD Name
- HDD Serial Number
-
Security Mode
-
TCG Device Type
• Estimated Time - Admin Pwd Status
Security Function
Use this feature to enable or disable the BIOS security frozen command for SATA and NVMe devices. The options are Disable, Set Password, Security Erase - Password, Security Erase - PSID, and Security Erase - Wtihout Password.
Password
Use this feature to set a password for the Supermicro HDD Security Function.
Lockdown Mode
Use this feature to put the BIOS into lockdown mode. The options are Enabled and Disabled.
▶Secure Boot
This section displays the contents of the following secure boot features:
- System Mode
- Vendor Keys
- Secure Boot
Secure Boot
Use this feature to enable secure boot. The options are Disabled and Enabled.
Secure Boot Mode
Use this item to configure Secure Boot variables without authentication. The options are Standard and Custom.
CSM Support
This feature is for manufacturing debugging purposes.
▶ Enter Audit Mode
This submenu can only be used if current System Mode is set to User (refer to Exit Deployed Mode). The PK variable will be erased on transition to Audit Mode.
▶ Enter Audit Mode
Provision Factory Defaults
Use this feature to install the factory default secure boot keys after the platform reset and while the system is in setup mode. The options are Disabled and Enabled.
▶ Reset to Setup Mode
This feature deletes all Secure Boot key databases from NVRAM.
▶ Export Secure Boot variables
This feature allows you to copy NVRAM content of Secure boot variables to files in a root folder on a file system device.
Enroll Efi Image
This feature allows the image to run in Secure Boot Mode. Enroll SHA256 Hash Certificate of the image into the Authorized Signature Database.
Device Guard Ready
▶Remove 'UEFI CA' from DB
This feature allows you to decide if all secure boot variables should be saved.
Select Yes to restore the DB defaults.
Secure Boot Variable
▶ Platform Key (PK)
Update
Select Yes to load the new Platform Keys (PK) from the manufacturer's defaults. Select No to load the Platform Keys from a file.
▶Key Exchange Key
Update
Select Yes to load the KEK from the manufacturer's defaults. Select No to load the Key Exchange Keys from a file.
Append
Select Yes to add the KEK from the manufacturer's defaults list to the existing KEK. Select No to load the KEK from a file.
▶ Authorized Signatures
Update
Select Yes to load the DB from the manufacturer's defaults. Select No to load the DB from a file.
Append
Select Yes to add the DB from the manufacturer's defaults list to the existing DB. Select No to load the DB from a file.
▶ Forbidden Signatures
Update
Select Yes to load the DBX from the manufacturer's defaults. Select No to load the DBX from a file.
Append
Select Yes to add the DBX from the manufacturer's defaults list to the existing DBX. Select No to load the DBX from a file.
▶ Authorized TimeStamps
Update
Select Yes to load the DBT from the manufacturer's defaults. Select No to load the DBT from a file.
Append
Select Yes to add the DBT from the manufacturer's defaults list to the existing DBT. Select No to load the DBT from a file.
OsRecovery Signature
Update
Select Yes to load the DBR from the manufacturer's defaults. Select No to load the DBR from a file.
Append
Select Yes to add the DBR from the manufacturer's defaults list to the existing DBR. Select No to load the DBR from a file.
4.7 Boot
Use this menu to configure Boot settings.

text_image
Auto Setup - AMI Main Advanced Event Logs IFMI Security Boot Save & Exit Boot Configuration Boot Mode Select [UEFI] LEGACY to EFI Support [Disabled] FIXED BOOT ORDER Priorities Boot Option #1 [UEFI Hard Disk] Boot Option #2 [UEFI CD/DVD] Boot Option #3 [UEFI USB Hard Disk] Boot Option #4 [UEFI USB CD/DVD] Boot Option #5 [UEFI USB Key] Boot Option #6 [UEFI USB Floppy] Boot Option #7 [UEFI USB Lan] Boot Option #8 [UEFI Network:(B24/D0/F0) UEFI PXE IFv4: Intel(R) Ethernet Controller X550(MAC:3_______) ] Boot Option #9 [UEFI AP:UEFI: Built-in EFI Shell] Delete Boot Option Select boot mode LEGACY/UEFI ++: Select Screen ↑↓: Select Item Enter: Select +/-: Change Opt. F1: General Help F2: Previous Values F3: Optimized Defaults F4: Save & Exit ESC: Exit Version 2.21.1278 Copyright (C) 2020 AMIBoot Mode Select
Use this feature to select the type of device that the system is going to boot from. The options are Legacy, UEFI, and Dual.
Legacy to EFI Support
Select Enabled to boot EFI OS support after Legacy boot order has failed. The options are Disabled and Enabled.
Fixed Boot Order Priorities
This feature prioritizes the order of bootable devices that the system boots from. Press
*If the feature "Boot Mode Select" is set to Legacy, UEFI, or Dual, the following features are displayed:
- Boot Option #1
- Boot Option #2
- Boot Option #3
-
Boot Option #4
-
Boot Option #5
- Boot Option #6
- Boot Option #7
- Boot Option #8
- Boot Option #9
▶ Delete Boot Option
This feature allows you to select a boot device to delete from the boot priority list.
Delete Boot Option
Use this feature to remove an EFI boot option from the boot priority list.
▶UEFI NETWORK Drive BBS Priorities
This feature sets the system boot order of detected devices.
- Boot Option #1 - Boot Option #12
▶UEFI Application Boot Priorities
This feature sets the system boot order of detected devices.
- Boot Option #1
4.8 Save & Exit
Use this menu to save settings and exit from the BIOS.

text_image
Antio Setup - AMI Main Advanced Event Logs IFMI Security Boot Save & Exit Save Options Discard Changes and Exit Save Changes and Reset Save Changes Discard Changes Default Options Restore Optimized Defaults Save as User Defaults Restore User Defaults Boot Override (B24/DO/F0) UEFI PXE IPv4: Intel(R) Ethernet Controller X550 (MAC: ____) (B24/DO/F1) UEFI PXE IPv4: Intel(R) Ethernet Controller X550 (MAC: ____) (B25/DO/F0) UEFI PXE IPv4: Intel(R) I350 Gigabit Network Connection (MAC: ____) (B25/DO/F1) UEFI PXE IPv4: Intel(R) I350 Gigabit Network Connection (MAC: ____) (B25/DO/F2) UEFI PXE IPv4: Intel(R) I350 Gigabit Network Connection (MAC: ____) (B25/DO/F3) UEFI PXE IPv4: Intel(R) I350 Gigabit Network Connection (MAC: ____) Exit system setup without saving any changes. +: Select Screen T1: Select Item Enter: Select +/-: Change Opt. F1: General Help F2: Previous Values F3: Optimized Defaults F4: Save & Exit ESC: Exit Version 2.21.1278 Copyright (C) 2020 AMISave Options
Discard Changes and Exit
Select this option to quit the BIOS Setup without making any permanent changes to the system configuration, and reboot the computer. Select Discard Changes and Exit from the Save & Exit menu and press
Save Changes and Reset
After completing the system configuration changes, select this option to save the changes you have made. This will not reset (reboot) the system.
Save Changes
When you have completed the system configuration changes, select this option to leave the BIOS setup utility and reboot the computer for the new system configuration parameters to take effect. Select Save Changes from the Save & Exit menu and press
Discard Changes
Select this option and press
Default Options
Load Optimized Defaults
To set this feature, select Restore Defaults from the Save & Exit menu and press
Save As User Defaults
To set this feature, select Save as User Defaults from the Save & Exit menu and press
To set this feature, select Restore User Defaults from the Save & Exit menu and press
Boot Override
This feature allows you to override the Boot priorities sequence in the Boot menu, and immediately boot the system with a device specified instead of the one specified in the boot list. This is an one-time override.
(B24/D0/F0) UEFI PXE IPv4: Intel(R) Ethernet Controller X550 (MAC:xxxxxxxxxxxxx)
(B24/D0/F1) UEFI PXE IPv4: Intel(R) Ethernet Controller X550 (MAC: xxxxxxxxxxxxx)
(B25/D0/F0) UEFI PXE IPv4: Intel(R) I350 Gigabit Network Controller (MAC:xxxxxxxxxxxxx)
(B25/D0/F1) UEFI PXE IPv4: Intel(R) I350 Gigabit Network Controller (MAC:xxxxxxxxxxxxx)
(B25/D0/F2) UEFI PXE IPv4: Intel(R) I350 Gigabit Network Controller (MAC:xxxxxxxxxxxxx)
(B25/D0/F3) UEFI PXE IPv4: Intel(R) I350 Gigabit Network Controller (MAC:xxxxxxxxxxxx)
(B24/D0/F0) UEFI PXE IPv6: Intel(R) Ethernet Controller X550 (MAC:xxxxxxxxxxxxx)
(B24/D0/F1) UEFI PXE IPv6: Intel(R) Ethernet Controller X550 (MAC:xxxxxxxxxxxxx)
(B25/D0/F0) UEFI PXE IPv6: Intel(R) Ethernet Controller X550 (MAC:xxxxxxxxxxxxx)
(B25/D0/F1) UEFI PXE IPv6: Intel(R) Ethernet Controller X550 (MAC:xxxxxxxxxxxxx)
(B25/D0/F2) UEFI PXE IPv6: Intel(R) Ethernet Controller X550 (MAC:xxxxxxxxxxxxx)
(B25/D0/F3) UEFI PXE IPv6: Intel(R) Ethernet Controller X550 (MAC:xxxxxxxxxxxxx)
UEFI: Built-in EFI Shell
Launch EFI Shell from filesystem device
Appendix A
Software Installation
A.1 Installing Software Programs
The Supermicro site that contains drivers and utilities for your system is at https://www.supermicro.com/wdl/driver/. Some of these must be installed, such as the chipset driver.
After accessing the site, go into the CDR_Images directory and locate the ISO file for your motherboard. Download this file to create a CD/DVD of the drivers and utilities it contains. (You may also use a utility to extract the ISO file if preferred.)
After creating a CD/DVD with the ISO files, insert the disk into the CD/DVD drive on your system and the display shown in Figure A-1 should appear.
Another option is to go to the Supermicro website at http://www.supermicro.com/products/. Find the product page for your motherboard here, where you may download individual drivers and utilities to your hard drive or a USB flash drive and install from there.

Note: To install the Windows OS, please refer to the instructions posted on our website at http://www.supermicro.com/support/manuals/.

text_image
SUPERMICRO X12SPM-TF Motherboard Drivers & Tools (Win10) Intel Chipset: INF files Microsoft Net Framework 4.5.2 (Optional) ASPEED Graphics Driver Intel Virtual RAID on CPU Intel PRO Network Connections Drivers SUPERMICRO SuperDoctor 5 Build driver disketes and manuals Browse CD Auto Start Up Next Time For more information, please visit SUPERMICRO's web sitesFigure A-1. Driver/Tool Installation Display Screen
Click the icons showing a hand writing on the paper to view the readme files for each item. Click a computer icon to the right of an item to install an item (from top to bottom) one at a time. After installing each item, you must reboot the system before proceeding with the next item on the list. The bottom icon with a CD on it allows you to view the entire contents of the CD.
When making a storage driver disk by booting into a driver CD, please set the SATA Configuration to "Compatible Mode" and configure SATA as IDE in the BIOS Setup. After making the driver diskette, be sure to change the SATA settings back to your original settings.
A.2 SuperDoctor® 5
The Supermicro SuperDoctor 5 is a hardware monitoring program that functions in a command-line or web-based interface in Windows and Linux operating systems. The program monitors system health information such as CPU temperature, system voltages, system power consumption, fan speed, and provides alerts via email or Simple Network Management Protocol (SNMP).
SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize your system monitoring needs. With SuperDoctor 5 Management Server (SSM Server), you can remotely control power on/off and reset chassis intrusion for multiple systems with SuperDoctor 5 or IPMI. SD5 Management Server monitors HTTP, FTP, and SMTP services to optimize the efficiency of your operation.
Figure A-2. SuperDoctor 5 Interface Display Screen (Health Information)

text_image
SuperDoctor 5 Health Info MOTHERBOARD: KNO TU-LN4+ Fan Speed 10A 20A 30A 40A 50A 60A 70A 80A 90A 100A 110A 120A 130A 140A 150A 160A 170A 180A 190A 200A 210A 220A 230A 240A 250A 260A 270A 280A 290A 300A 310A 320A 330A 340A 350A 360A 370A 380A 390A 400A 410A 420A 430A 440A 450A 460A 470A 480A 490A 500A 510A 520A 530A 540A 550A 560A 570A 580A 590A 600A 610A 620A 630A 640A 650A 660A 670A 680A 690A 700A 710A 720A 730A 740A 750A 760A 770A 780A 790A 800A 810A 820A 830A 840A 850A 860A 870A 880A 890A 900A 910A 920A 930A 940A 950A 960A 970A 980A 990A 1000A
Note: The SuperDoctor 5 program and user's manual can be downloaded from the Supermicro website at http://www.supermicro.com/products/nfo/sms_sd5.cfm.
A.3 IPMI
The X12SPM-TF/-LN4F/-LN6TF supports the Intelligent Platform Management Interface (IPMI). IPMI is used to provide remote access, monitoring and management. There are several BIOS settings that are related to IPMI.
Supermicro ships standard products with a unique password for the BMC ADMIN user. This password can be found on a label on the motherboard. For general documentation and information on IPMI, please visit our website at: http://www.supermicro.com/products/nfo/IPMI.cfm.
Appendix B
Standardized Warning Statements
The following statements are industry standard warnings, provided to warn the user of situations which have the potential for bodily injury. Should you have questions or experience difficulty, contact Supermicro's Technical Support department for assistance. Only certified technicians should attempt to install or configure components.
Read this section in its entirety before installing or configuring components.
These warnings may also be found on our website at http://www.supermicro.com/about/policies/safety_information.cfm.
Battery Handling

Warning! There is the danger of explosion if the battery is replaced incorrectly. Replace the battery only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions
電池の取り扱い