Supermicro

SuperServer 6018U-TRTP+ - Server Supermicro - Free user manual and instructions

Find the device manual for free SuperServer 6018U-TRTP+ Supermicro in PDF.

📄 128 pages English EN Download 💬 AI Question
Notice Supermicro SuperServer 6018U-TRTP+ - page 7
Pick your language and provide your email: we'll send you a specifically translated version.

User questions about SuperServer 6018U-TRTP+ Supermicro

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Server in PDF format for free! Find your manual SuperServer 6018U-TRTP+ - Supermicro and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. SuperServer 6018U-TRTP+ by Supermicro.

USER MANUAL SuperServer 6018U-TRTP+ Supermicro

natural_image Front view of a rack-mounted server unit with multiple ports and connectors (no visible text or labels)

USER'S MANUAL

Revision 1.0e

The information in this User's Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates. Please Note: For the most up-to-date version of this manual, please see our web site at www.supermicro.com.

Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product described in this manual at any time and without notice. This product, including software and documentation, is the property of Supermicro and/or its licensors, and is supplied only under a license. Any use or reproduction of this product is not allowed, except as expressly permitted by the terms of said license.

IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTWARE, OR DATA STORED OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA.

Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Super Micro's total liability for all claims will not exceed the price paid for the hardware product.

FCC Statement: This equipment has been tested and found to comply with the limits for a Class A or Class B digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in industrial environment for Class A device or in residential environment for Class B device. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the manufacturer's instruction manual, may cause harmful interference with radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case you will be required to correct the interference at your own expense.

California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. "Perchlorate Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate"

Supermicro SuperServer 6018U-TRTP+ - USER'S MANUAL - 1

WARNING: This product can expose you to chemicals including lead, known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.

Manual Revision 1.0e

Release Date: May 20, 2021

Unless you request and receive written permission from Super Micro Computer, Inc., you may not copy any part of this document.

Information in this document is subject to change without notice. Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.

Copyright © 2021 by Super Micro Computer, Inc.

All rights reserved.

Printed in the United States of America

Preface

About this Manual

This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the SuperServer 6018U-T Series. Installation and maintenance should be performed by experienced technicians only.

Please refer to the server specifications page on our Web site for updates on supported memory, processors and operating systems (www.supermicro.com).

Notes

For your system to work properly, please follow the links below to download all necessary drivers/utilities and the user's manual for your server.

• Supermicro product manuals: https://www.supermicro.com/support/manuals/
• Product drivers and utilities: https://www.supermicro.com/wdl
- Product safety info: https://super-dev/about/policies/safety_information.cfm

If you have any questions, please contact our support team at: support@supermicro.com

This manual may be periodically updated without notice. Please check the Supermicro Web site for possible updates to the manual revision level.

Secure Data Deletion

A secure data deletion tool designed to fully erase all data from storage devices can be found on our website: https://www.supermicro.com/about/policies/disclaimer.cfm?url=/wftp/utility/Lot9_Secure_Data_Deletion_Utility/

Warnings

Special attention should be given to the following symbols used in this manual.

Supermicro SuperServer 6018U-TRTP+ - Warnings - 1

Warning! Indicates important information given to prevent equipment/property damage or personal injury.

Supermicro SuperServer 6018U-TRTP+ - Warnings - 2

Warning! Indicates high voltage may be encountered when performing a procedure.

Contents

Chapter 1 Introduction

1-1 Overview 1-1
1-2 Serverboard Features 1-2

Processors 1-2

Memory 1-2

Onboard Serial ATA....1-2

Input/Output 1-2

1-3 Server Chassis Features 1-3

System Power 1-3

Drives 1-3

PCI Expansion Slots 1-3

Front Control Panel....1-3

Cooling System 1-3

1-4 Contacting Supermicro.... 1-5

Chapter 2 Server Installation

2-1 Overview 2-1
2-2 Unpacking the System....2-1
2-3 Preparing for Setup....2-1

Choosing a Setup Location....2-1

2-4 Warnings and Precautions 2-2

Rack Precautions 2-2
Server Precautions....2-2
Rack Mounting Considerations 2-3

2-5 Installing the System into a Rack 2-4

Identifying the Sections of the Rack Rails 2-4
Installing the Optional Inner Rail Extensions....2-5
Assembling the Outer Rails 2-6
Installing the Outer Rails onto the Rack 2-7
Installing and Removing the Chassis From a Rack 2-8
Installing the Server into a Telco Rack 2-9

Chapter 3 System Interface....3-1

3-1 Overview 3-1
3-2 Control Panel Buttons 3-2
3-3 Control Panel LEDs 3-2

Overheating....3-3

Overheat Temperature Setting 3-3

Responses....3-3

3-4 Drive Carrier LEDs.... 3-4
3-5 Power Supply LEDs....3-4

Chapter 4 Standardized Warning Statements for AC Systems

About Standardized Warning Statements....4-1
Warning Definition 4-1
Installation Instructions....4-4
Circuit Breaker 4-5
Power Disconnection Warning 4-6
Equipment Installation....4-8
Restricted Area....4-9
Battery Handling....4-10
Redundant Power Supplies (if applicable to your system)....4-12
Backplane Voltage (if applicable to your system)....4-13
Comply with Local and National Electrical Codes....4-14
Product Disposal 4-15
Hot Swap Fan Warning 4-16
Power Cable and AC Adapter 4-18

Chapter 5 Advanced Serverboard Setup

5-1 Handling the Serverboard 5-1

Precautions 5-1
Unpacking 5-1

5-2 Installing the Processor and Heatsink 5-2

Installing an LGA 2011 Processor....5-2
Installing a CPU Heatsink 5-5
Removing the Heatsink 5-5

5-3 Connecting Cables....5-6

Connecting Data Cables 5-6
Connecting Power Cables 5-6
Connecting the Control Panel....5-6

5-4 I/O Ports 5-7

LAN Ports 5-7

5-5 Installing Memory 5-8

Memory Support....5-9
Processor & Memory Module Population Configuration 5-9

5-6 Serverboard Details 5-10

X10DRU-i+ Quick Reference 5-11

5-7 Connector Definitions.... 5-13

5-9 Jumper Settings 5-18

5-10 Onboard Indicators....5-20

5-11 SATA Ports 5-21

5.12 Microsoft Windows OS Installation 5-22

5-13 Installing Software....5-24

SuperDoctor® 5 5-25

5.14 IPMI 5-26

BMC ADMIN User Password 5-26

5-15 Onboard Battery....5-27

Chapter 6 Advanced Chassis Setup

6-1 Static-Sensitive Devices....6-1

Precautions 6-1

6-2 Removing the Power....6-2

6-3 Control Panel 6-2

6-4 Chassis Cover....6-3

6-5 Installing Drives....6-4

6-6 Installing Expansion Cards 6-6

Internal Expansion Card 6-7

6-7 System Cooling 6-8

Optional Fans 6-8

System Fan Replacement....6-9

Air Shroud 6-10

6-8 Power Supply....6-11

6-9 Removing the Ultra Riser Card....6-12

Chapter 7 BIOS

7-1 Introduction....7-1

Starting BIOS Setup Utility....7-1

How To Change the Configuration Data....7-1

Starting the Setup Utility 7-2

7-2 Main Setup 7-2

7-3 Advanced Setup Configurations.... 7-4

7-4 Event Logs 7-25

7-5 IPMI 7-27

7-6 Security....7-29

7-7 Boot 7-30

7-8 Save & Exit 7-31

Appendix A BIOS Error Beep Codes

Appendix B UEFI BIOS Recovery Instructions

Appendix C System Specifications

Chapter 1

Introduction

1-1 Overview

The SuperServer 6018U-T Series is a high-end server comprised of the SC819UTQ-R750 1U server chassis and the X10DRU-i+ dual processor serverboard. Refer to the Supermicro web site (www.supermicro.com) for information on operating systems that have been certified for use with the system.

Each of the models offer slightly different capabilities by means of the pre-installed Ultra riser card.

6018U-T Series Models
System LAN Ports Ultra Riser Card
6018U-TR4+ FourGbE AOC-UR-i4G
6018U-TRT+ Two10GBase-T AOC-UR-i2XT
6018U-TR4T+ Four10GBase-T AOC-UR-i4XT
6018U-TRTP+ Two10G SFP+ AOC-URN2-i2XS

In addition to the above components, the server includes:

• SAS backplane (BPN-SAS-815TQ)
• Four to eight 4cm fans (FAN-0101L4)
• One air shroud (MCP-310-81902-0B)
• Two passive CPU heatsinks (SNK-P0047PS)
- Riser Cards: One RSC-R1UW-2E16-O-P One RSC-R1UW-E8R-O-P
• Four drive carriers (MCP-220-00075-0B)

Note: For your system to work properly, please follow the links below to download all necessary drivers/utilities and the user's manual for your server.

  • Product manuals: http://www.supermicro.com/support/manuals/
    • Product drivers and utilities: https://www.supermicro.com/wdl
  • Product safety information: http://www.supermicro.com/about/policies/safety_information.cfm
  • For support, email support@supermicro.com.

1-2 Serverboard Features

At the heart of the SuperServer 6018U-T Series lies the X10DRU-i+, a dual processor serverboard based on the Intel PCH C612 chipset. Below are the main features of the serverboard. Figure 1-1 shows a block diagram of the chipset.

Processors

The server supports single or dual E5-2600 v3/v4 series processors in R3 LGA 2011 sockets (Socket R3). Refer to the Supermicro web site for a complete listing of supported processors.

Memory

The server features 24 DIMM slots that can support up to 3 TB of ECC Load Reduction (LRDIMM) or up to 768 GB of ECC Registered (RDIMM) DDR4-2400/2133/1866/1600/1333 SDRAM.

Onboard Serial ATA

A SATA controller is integrated into the chipset to provide a ten-port SATA subsystem. Six of the ports are supported by the Intel PCH and four of the ports are supported by the Intel SCU. The SATA 3.0 ports are connected to the backplane by default. RAID 0, 1, 5 and 10 are supported by Intel RSTe Software RAID.

Input/Output

The system comes with basic I/O ports for VGA, COM, five USB 3.0, and one IPMI connection. In addition, there are several possible networking configurations depending on the pre-installed Ultra riser card. See the table in Section 1-1.

1-3 Server Chassis Features

The 6018U-T Series is built upon the SC819UTQ-R750 chassis. Details on the chassis and on servicing procedures can be found in Chapter 6. The following is a general outline of the main features of the chassis.

System Power

The chassis features a redundant 750W power supply consisting of two power modules, so one may be replaced without powering down the system.

Drives

The chassis supports up to four hot-swap 3.5" SAS or SATA hard disk drives. Two other bays accommodate slim-type peripheral drives.

PCI Expansion Slots

The chassis supports two full-height, full-length PCIe expansion cards, or one double width graphics processor unit (GPU). The chassis also supports one low profile card, and the pre-installed Ultra riser card offers another internal low profile card slot. Riser cards and brackets are required. Additional fans are recommended; see Section 6-7.

Front Control Panel

The chassis front control panel provides system monitoring lights and power control buttons.

Cooling System

The system has an innovative cooling design that features four to eight sets of 4-cm counter-rotating fans located in the middle section of the chassis. Fan speed may be controlled by IPMI to respond to fluctuations in system temperature. An air shroud directs air flow to components the need cooling. The power supply module also includes a cooling fan.

Supermicro SuperServer 6018U-TRTP+ - Cooling System - 1

flowchart System architecture diagram showing CPU-IO and Microcontroller components with signal flow from DDR3 to Ultra IO via UART, PCH, and I/O interfaces.

Figure 1-1. Intel PCH C612 Chipset: System Block Diagram

Note: This is a general block diagram. Please see Chapter 5 for details.

1-4 Contacting Supermicro

Headquarters

Address: Super Micro Computer, Inc.

980 Rock Ave.

San Jose, CA 95131 U.S.A.

Tel: +1 (408) 503-8000

Fax: +1 (408) 503-8008

Email: marketing@supermicro.com (General Information)

support@supermicro.com (Technical Support)

Web Site: www.supermicro.com

Europe

Address: Super Micro Computer B.V.

's-Hertogenbosch, The Netherlands

Tel: +31 (0) 73-6400390

Fax: +31 (0) 73-6416525

Email: sales@supermicro.nl (General Information)

support@supermicro.nl (Technical Support)

rma@supermicro.nl (Customer Support)

Web Site: www.supermicro.nl

Asia-Pacific

Address: Super Micro Computer, Inc.

3F, No. 150, Jian 1st Rd.

Zhonghe Dist., New Taipei City 235

Taiwan (R.O.C)

Tel: +886-(2) 8226-3990

Fax: +886-(2) 8226-3992

Email: support@supermicro.com.tw

Web Site: www.supermicro.com.tw

Notes

Chapter 2

Server Installation

2-1 Overview

This chapter provides a quick setup checklist to get your system up and running. This quick setup assumes that your system has come to you with the processors and memory preinstalled. If your system is not already fully integrated with a serverboard, processors, system memory etc., please turn to the chapter or section noted in each step for details on installing specific components.

2-2 Unpacking the System

You should inspect the box the chassis was shipped in and note if it was damaged in any way. If the chassis itself shows damage, file a damage claim with the carrier who delivered it.

2-3 Preparing for Setup

Decide on a suitable location for the rack unit that will hold your chassis. It should be a clean, dust-free area that is well ventilated. Avoid areas where heat, electrical noise and electromagnetic fields are generated. A nearby grounded power outlet. is required

The box your chassis was shipped in should include two sets of rail assemblies, two rail mounting brackets and the mounting screws to mount the system into the rack. Please read this chapter in its entirety before beginning the installation procedure.

Choosing a Setup Location

  • Leave enough clearance in front of the rack to enable you to open the front door completely (\~25 inches) and approximately 30 inches of clearance in the back of the rack to allow for sufficient airflow and ease in servicing. This product is for installation only in a Restricted Access Location (dedicated equipment rooms, service closets and the like).
  • This product is not suitable for use with visual display work place devices according to §2 of the German Ordinance for Work with Visual Display Units.

2-4 Warnings and Precautions

Rack Precautions

  • Ensure that the leveling jacks on the bottom of the rack are fully extended to the floor with the full weight of the rack resting on them.
  • In single rack installation, stabilizers should be attached to the rack. In multiple rack installations, the racks should be coupled together.
  • Always make sure the rack is stable before extending a component from the rack.
  • You should extend only one component at a time - extending two or more simultaneously may cause the rack to become unstable.
  • Rack-mounted equipment should not be used as a shelf or work space.

Server Precautions

  • Review the electrical and general safety precautions in Chapter 4.
  • Determine the placement of each component in the rack before you install the rails.
  • Install the heaviest server components on the bottom of the rack first, and then work up.
  • Use a regulating uninterruptible power supply (UPS) to protect the server from power surges, voltage spikes and to keep your system operating in case of a power failure.
  • Allow the hot plug SATA drives and power supply modules to cool before touching them.
  • Always keep the rack's front door and all panels and components on the servers closed when not servicing to maintain proper cooling.

Rack Mounting Considerations

Ambient Operating Temperature

If installed in a closed or multi-unit rack assembly, the ambient operating temperature of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer's maximum rated ambient temperature (Tmra).

Reduced Airflow

Equipment should be mounted into a rack so that the amount of airflow required for safe operation is not compromised.

Mechanical Loading

Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading.

Circuit Overloading

Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection and power supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.

Reliable Ground

A reliable ground must be maintained at all times. To ensure this, the rack itself should be grounded. Particular attention should be given to power supply connections other than the direct connections to the branch circuit (i.e. the use of power strips, etc.).

Supermicro SuperServer 6018U-TRTP+ - Reliable Ground - 1

Warning! To prevent bodily injury when mounting or servicing this unit in a rack, you must take special precautions to ensure that the system remains stable. The following guidelines are provided to ensure your safety:

  • This unit should be mounted at the bottom of the rack if it is the only unit in the rack.
  • When mounting this unit in a partially filled rack, load the rack from the bottom to the top with the heaviest component at the bottom of the rack.
  • If the rack is provided with stabilizing devices, install the stabilizers before mounting or servicing the unit in the rack.
  • Slide rail mounted equipment is not to be used as a shelf or a work space.

2-5 Installing the System into a Rack

This section provides information on installing the chassis into a rack unit with the rails provided. There are a variety of rack units on the market, which may mean that the assembly procedure differs slightly. You should also refer to the installation instructions that came with the rack unit you are using.

Note: This rail will fit a rack between 26" and 33.5" deep.

Supermicro SuperServer 6018U-TRTP+ - 2-5 Installing the System into a Rack - 1

Stability hazard. The rack stabilizing mechanism must be in place, or the rack must be bolted to the floor before you slide the unit out for servicing. Failure to stabilize the rack can cause the rack to tip over.

Identifying the Sections of the Rack Rails

The chassis package includes two sets of rack rails, one set for the right side of the chassis and one for the left. Each set consists of an inner rail that is fixed directly to the chassis and an outer rail that attaches to the rack.

The inner rails are pre-attached and do not interfere with normal use of the chassis if you decide not to install it into a rack.

Supermicro SuperServer 6018U-TRTP+ - Identifying the Sections of the Rack Rails - 1

text_image Inner Rail-- pre-attached to the chassis Inner Rail Extension-- attach to the chassis Outer Rails-- slide together Front and Rear Brackets-- attach to the rack

Figure 2-1. Identifying the Sections of the Rack Rails

Installing the Optional Inner Rail Extensions

Attaching the optional inner rail extensions allows you to pull the server farther out of the rack. Do not put downward force on the chassis when it is fully extended.

Installing the Inner Rail Extensions

  1. Place the inner rail extensions at the side of the chassis. Align the holes of the inner rail extension with the hooks on the side of the chassis. Make sure the extension faces outward like the inner rail.
  2. Slide the extension toward the front of the chassis and under the hooks until the quick release bracket snaps into place, securing the extension to the chassis.
  3. If desired, you can install a screw to further secure the extension to the chassis.
  4. Repeat for the other inner rail extension.

Supermicro SuperServer 6018U-TRTP+ - Installing the Inner Rail Extensions - 1

text_image Chassis Front

Figure 2-2. Installing the Inner Rail Extensions

Assembling the Outer Rails

Each outer rail comes in two sections that must be assembled before mounting onto the rack.

Assembling the Outer Rails

  1. Identify the left and right outer rails by examining the ends, which bend outward. Match the left front outer rail with the left rear outer rail and the same for the right rails.
  2. Align the round post in the rear rail (B) with the round hole at the end of the slot in the front rail (A), and slide the front section into the rear section.

Supermicro SuperServer 6018U-TRTP+ - Assembling the Outer Rails - 1

text_image Round Hole Secure to the front of the rack Slide outer rails together Secure to the rear of the rack Assembling the sections of the outer rail A B

Supermicro SuperServer 6018U-TRTP+ - Assembling the Outer Rails - 2

text_image Outer rail assembled

Supermicro SuperServer 6018U-TRTP+ - Assembling the Outer Rails - 3

text_image Bracket with Square Pegs

Figure 2-3. Assembling the Outer Rails

Installing the Outer Rails onto the Rack

Each end of the assembled outer rail includes a bracket with square pegs to fit into your rack holes. If you have an older rack with round holes, these brackets must be removed, and you must use screws to secure the rail to the rack.

Outer Rail Installation

  1. Align the square pegs on the front end of the rail with the square holes on the front of the rack (C). Push the rail into the rack until the quick release bracket snaps into place, securing the rail to the rack. Keep the rail horizontal.
  2. Adjust the rail to reach just past the full depth of your rack.
  3. Align the square pegs on the rear end of the rail to the holes on the rack (D) and push the rail into the rack until the quick release bracket snaps into place, securing the rail to the rack.
  4. Repeat the procedure for the other outer rail assembly.

Supermicro SuperServer 6018U-TRTP+ - Outer Rail Installation - 1

text_image Technical diagram of a server rack structure with labeled components C and D

Figure 2-4. Installing the Outer Rails to the Rack

Note: The figure above is for illustrative purposes only. Always install servers at the bottom of the rack first.

Supermicro SuperServer 6018U-TRTP+ - Outer Rail Installation - 2

Stability hazard. The rack stabilizing mechanism must be in place, or the rack must be bolted to the floor before you slide the unit out for servicing. Failure to stabilize the rack can cause the rack to tip over.

Installing and Removing the Chassis From a Rack

Installation into a Rack

  1. Slide the inner rail extensions into the front of the outer rails.
  2. Push the chassis backward into the rack until it clicks into the locked position.

Removing the Chassis From a Rack

  1. Press the outer rail latch to release the chassis.
  2. Carefully slide the chassis forward, off the outer rails and out of the chassis.

Supermicro SuperServer 6018U-TRTP+ - Removing the Chassis From a Rack - 1

text_image Outer Rail Latch

Figure 2-5. Server Installation and Removal

Note: The figure above is for illustrative purposes only. Always install servers at the bottom of the rack first.

Supermicro SuperServer 6018U-TRTP+ - Removing the Chassis From a Rack - 2

Warning: Do not pick up the server with the front handles. They are designed to pull the system from a rack only.

Installing the Server into a Telco Rack

Optional brackets are needed to install the server to a telco (open type) rack.

To install the server into a Telco type rack, use the two L-shaped brackets on either side of the chassis (four total). First, determine how far follow the server will extend out the front of the rack. Larger chassis should be positioned to balance the weight between front and back. If a bezel is included on your server, remove it. Then attach the two front brackets to each side of the chassis, then the two rear brackets positioned with just enough space to accommodate the width of the telco rack. Finish by sliding the chassis into the rack and tightening the brackets to the rack.

Supermicro SuperServer 6018U-TRTP+ - Installing the Server into a Telco Rack - 1

natural_image Isometric line drawing of a server rack unit with mounting brackets and internal components (no text or symbols)

Figure 2-6. Installing the Server into a Telco Rack

Note: Figures are for illustrative purposes only. Servers should always be installed into racks starting at the bottom.

Notes

Chapter 3

System Interface

3-1 Overview

The chassis includes:

  • A control panel on the front that houses power buttons and status monitoring lights
    • Status lights on externally accessible hard drives
    • Status lights for the power supply visible from the back of the chassis

These elements are described in this chapter with possible responses.

Supermicro SuperServer 6018U-TRTP+ - 3-1 Overview - 1

text_image UID i² RESET

Figure 3-1. Control Panel

3-2 Control Panel Buttons

The chassis includes three push-buttons.

Supermicro SuperServer 6018U-TRTP+ - 3-2 Control Panel Buttons - 1

Power: The main power switch applies or removes power from the power supply to the server system. Turning off system power with this button removes the main power but standby power is still supplied to the system.

Supermicro SuperServer 6018U-TRTP+ - 3-2 Control Panel Buttons - 2

RESET

Reset: Reboots the system.

Supermicro SuperServer 6018U-TRTP+ - RESET - 1

Supermicro SuperServer 6018U-TRTP+ - RESET - 2

UID: Depressing the UID (unit identifier) button illuminates an LED on both the front and rear of the chassis for easy system location in large stack configurations. The LED will remain on until the button is pushed a second time. Another UID button on the rear of the chassis serves the same function.

3-3 Control Panel LEDs

There are five LEDs that provide status information about the system.

Supermicro SuperServer 6018U-TRTP+ - 3-3 Control Panel LEDs - 1

Information LED: Alerts operator of several states, as noted in the table below.

Information LED
Status Description
Continuously on and redAn overheat condition has occurred. (This may be caused by cable congestion.)
Blinking red (1Hz) Fan failure,check for an inoperative fan.
Blinking red (0.25Hz) Power failure,check for a non-operational power supply.
Solid blueUID has been activated locally to locate the server in a rack environment.
Blinking blueUID has been activated using IPMI to locate the server in a rack environment.

Supermicro SuperServer 6018U-TRTP+ - 3-3 Control Panel LEDs - 2

NIC: Indicates network activity on GLAN2 when flashing.

Supermicro SuperServer 6018U-TRTP+ - 3-3 Control Panel LEDs - 3

NIC: Indicates network activity on GLAN1 when flashing.

Supermicro SuperServer 6018U-TRTP+ - 3-3 Control Panel LEDs - 4

HDD: Indicates activity on the hard drive when flashing.

Supermicro SuperServer 6018U-TRTP+ - 3-3 Control Panel LEDs - 5

Power: Indicates power is being supplied to the system power supply units. This LED should normally be illuminated when the system is operating.

Overheating

There are several possible responses if the system overheats.

Overheat Temperature Setting

Some backplanes allow the overheat temperature to be set at 45, 50, or 55 by changing a jumper setting. For more information, consult the backplane user manual at www.supermicro.com. (Click Support, then the Manuals link.)

Responses

If the server overheats:

  1. Use the LEDs to determine the nature of the overheating condition.
  2. Confirm that the chassis covers are installed properly.

  3. Check the routing of the cables and make sure all fans are present and operating normally.

  4. Verify that the heatsinks are installed properly.

3-4 Drive Carrier LEDs

The chassis includes externally accessible SAS/SATA drives. Each drive carrier displays two status LEDs on the front of the carrier.

LED Color Blinking Pattern Behavior for Device
Activity LEDGreen Solid On Green BlinkingSAS drive installed I/O activity
Status LEDRed Solid On Ffailed drive for SAS/SATA with RSTe support
Red Blinking at1 Hz Rebuild drive for SAS/SATA with RSTe support
Red Blinking with two blinks and one stop at 1 HzHot spare for SAS/SATA with RSTe support
Red On for five seconds, then offPower on for SAS/SATA with RSTe support
Red Blinking at4 Hz Identify drive for SAS/SATA with RSTe support

3-5 Power Supply LEDs

On the rear of the power supply module, an LED displays the status.

  • Solid Green: When illuminated, indicates that the power supply is on.
  • Blinking Green: When blinking, indicates that the power supply is plugged in and turned off by the system.
  • Blinking Amber: When blinking, indicates that the power supply has a warning condition and continues to operate.
  • Solid Amber: When illuminated, indicates that the power supply is plugged in and in an abnormal state. The server system might need service. Please contact Supermicro technical support.

Chapter 4

Standardized Warning Statements for AC Systems

About Standardized Warning Statements

The following statements are industry standard warnings, provided to warn the user of situations which have the potential for bodily injury. Should you have questions or experience difficulty, contact Supermicro's Technical Support department for assistance. Only certified technicians should attempt to install or configure components.

Read this chapter in its entirety before installing or configuring components in the Supermicro chassis. Some warnings may not apply for your system.

These warnings may also be found on our web site at www.supermicro.com/about/policies/safety_information.cfm.

Warning Definition

Supermicro SuperServer 6018U-TRTP+ - Warning Definition - 1

Warning!

This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents.

警告の定義

この警告サインは危険を意味します。

Installation Instructions

Supermicro SuperServer 6018U-TRTP+ - Installation Instructions - 1

Warning!

Read the installation instructions before connecting the system to the power source.

設置手順書

This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that the protective device is rated not greater than: 250 V, 20 A.

サーキット・ブレーカー

Power Disconnection Warning

Supermicro SuperServer 6018U-TRTP+ - Power Disconnection Warning - 1

Warning!

The system must be disconnected from all sources of power and the power cord removed from the power supply module(s) before accessing the chassis interior to install or remove system components.

電源切断の警告

Equipment Installation

Supermicro SuperServer 6018U-TRTP+ - Equipment Installation - 1

Warning!

Only trained and qualified personnel should be allowed to install, replace, or service this equipment.

機器の設置

This unit is intended for installation in restricted access areas. A restricted access area can be accessed only through the use of a special tool, lock and key, or other means of security. (This warning does not apply to workstations).

アクセス制限区域

There is the danger of explosion if the battery is replaced incorrectly. Replace the battery only with the same or equivalent type recommended by the manufacturer.

Dispose of used batteries according to the manufacturer's instructions

電池の取り扱い

Redundant Power Supplies (if applicable to your system)

Supermicro SuperServer 6018U-TRTP+ - Redundant Power Supplies (if applicable to your system) - 1

Warning!

This unit might have more than one power supply connection. All connections must be removed to de-energize the unit.

冗長電源装置

Backplane Voltage (if applicable to your system)

Supermicro SuperServer 6018U-TRTP+ - Backplane Voltage (if applicable to your system) - 1

Warning!

Hazardous voltage or energy is present on the backplane when the system is operating. Use caution when servicing.

バックプレーンの電圧

Comply with Local and National Electrical Codes

Supermicro SuperServer 6018U-TRTP+ - Comply with Local and National Electrical Codes - 1

Warning!

Installation of the equipment must comply with local and national electrical codes.

地方および国の電気規格に準拠

Ultimate disposal of this product should be handled according to all national laws and regulations.

製品の廃棄

text_image WARNING Hazardous moving parts. Keep away from moving fan blades.

Supermicro SuperServer 6018U-TRTP+ - Warning! - 1

The fans might still be turning when you remove the fan assembly from the chassis. Keep fingers, screwdrivers, and other objects away from the openings in the fan assembly's housing.

ファン・ホットスワップの警告

Power Cable and AC Adapter

Supermicro SuperServer 6018U-TRTP+ - Power Cable and AC Adapter - 1

Warning!

When installing the product, use the provided or designated connection cables, power cables and AC adaptors. Using any other cables and adaptors could cause a malfunction or a fire. Electrical Appliance and Material Safety Law prohibits the use of UL or CSA-certified cables (that have UL/CSA shown on the code) for any other electrical devices than products designated by Supermicro only.

電源コードとACアダプター

This chapter covers the steps required to install processors and heatsinks to the X10DRU-i+ serverboard, connect the data and power cables and install add-on cards. All serverboard jumpers and connections are described and a layout and quick reference chart are included in this chapter. Remember to close the chassis completely when you have finished working on the serverboard to protect and cool the system sufficiently.

5-1 Handling the Serverboard

Static electrical discharge can damage electronic components. To prevent damage to printed circuit boards, it is important to handle them very carefully (see Chapter 4). Also note that the size and weight of the serverboard can cause it to bend if handled improperly, which may result in damage. To prevent the serverboard from bending, keep one hand under the center of the board to support it when handling.

The following measures are generally sufficient to protect your equipment from static discharge.

Precautions

  • Use a grounded wrist strap designed to prevent static discharge.
  • Touch a grounded metal object before removing any board from its antistatic bag.
  • Handle a board by its edges only; do not touch its components, peripheral chips, memory modules or gold contacts.
  • When handling chips or modules, avoid touching their pins.
  • Put the serverboard, add-on cards and peripherals back into their antistatic bags when not in use.

Unpacking

The serverboard is shipped in antistatic packaging to avoid static damage. When unpacking the board, make sure the person handling it is static protected.

5-2 Installing the Processor and Heatsink

Notes:

• Always remove the power cord before adding, removing or changing a CPU.
- When receiving a serverboard without a processor pre-installed, make sure that the plastic CPU socket cap is in place and none of the socket pins are bent; otherwise, contact your retailer immediately.
- If you buy a CPU separately, use only an Intel-certified, multi-directional heatsink.
- Avoid placing direct pressure to the top of the processor package.
• Install the processor into the CPU socket before installing the heatsink.
• Refer to the Supermicro web site for updates on CPU support.

Installing an LGA 2011 Processor

Installing a CPU

  1. There are two levers on the LGA 2011 socket. First press and release the load lever labeled "Open 1st".

Supermicro SuperServer 6018U-TRTP+ - Installing a CPU - 1

text_image Close In OPEN In

Release the lever labeled "Open 1st"

  1. Press the second load lever labeled "Close 1st" to release the load plate from its locked position.

Release the lever labeled "Close 1st"
Supermicro SuperServer 6018U-TRTP+ - Installing a CPU - 2

text_image Close 1st Open 1st
  1. With the second lever fully retracted, gently push down on the "Open 1st" lever to loosen the load plate. Lift the load plate with your fingers to open it completely.

Supermicro SuperServer 6018U-TRTP+ - Installing a CPU - 3

text_image Open the load plate.
  1. Pop the plastic cap marked "Warning" out of the load plate.

  2. Holding the CPU carefully above the socket, orient the CPU so that all keys and edges will fit the socket.

  3. Carefully lower the CPU straight down into the socket. Do not move the CPU horizontally, and do not rub the pins of the socket. This may damage the CPU or the socket.

Supermicro SuperServer 6018U-TRTP+ - Installing a CPU - 4

text_image IMPORTANT! OPR1a

Supermicro SuperServer 6018U-TRTP+ - Installing a CPU - 5

natural_image Line drawing of a hand holding a small electronic device with a grid and ports (no text or symbols)

Caution: You can only install the CPU into the socket in one direction. Make sure that the CPU is properly inserted into the socket before closing the load plate. If it does not close properly, do not force it as it may damage your CPU. Instead, open the load plate again and double-check that the CPU is aligned properly.

  1. With the "Close 1st" lever fully retracted, gently close the load plate.

Supermicro SuperServer 6018U-TRTP+ - Installing a CPU - 6

text_image Gently close the load plate.
  1. Make sure the locking mechanism on the "Close 1st" lever catches the lip of the load plate. Close and lock the "Close 1st" lever.

Supermicro SuperServer 6018U-TRTP+ - Installing a CPU - 7

text_image Push down and lock the lever labeled "Close 1st". GUSB 1st OPEN 1st of and of

Engage the lip of the load plate and locking portion of the lever."

  1. Close and lock the "Open 1st" lever.

Supermicro SuperServer 6018U-TRTP+ - Installing a CPU - 8

text_image Q481n OPEN1n Push down and lock the lever labeled "Open 1st"

Installing a CPU Heatsink

  1. Place the heatsink on top of the CPU so that the four mounting holes are aligned with those on the retention mechanism.
  2. Screw in two diagonal screws (i.e. the #1 and the #2 screws) until just snug (do not over-tighten the screws, which may damage the CPU.)
  3. Finish the installation by fully tightening all four screws.

Supermicro SuperServer 6018U-TRTP+ - Installing a CPU Heatsink - 1

text_image Screw #1 Screw #3 Screw #2 Screw #4

Figure 5-1. Heatsink

Removing the Heatsink

Caution: We do not recommend removing the CPU or the heatsink. If you do need to remove the heatsink, please follow the instructions below to prevent damage to the CPU or the CPU socket.

  1. Unplug the power cord from the power supply.
  2. Unscrew and remove the heatsink screws in the opposite sequence shown in the picture above.
  3. Hold the heatsink and gently wriggle it to loosen it from the CPU. (Do not use excessive force!)

  4. Once the heatsink is loosened, remove it from the CPU.

  5. Clean the surface of the CPU and the heatsink to get rid of the old thermal grease. Reapply the proper amount of thermal grease before re-installing the heatsink.

5-3 Connecting Cables

Now that the processors are installed, the next step is to connect the cables to the serverboard. These include the data (ribbon) cables for the peripherals and control panel and the power cables.

Connecting Data Cables

The cables used to transfer data from the peripheral devices have been carefully routed in preconfigured systems to prevent them from blocking the flow of cooling air that moves through the system from front to back. If you need to disconnect any of these cables, you should take care to reroute them as they were originally after reconnecting them and be aware of the pin 1 locations. If you are configuring the system, keep the airflow in mind when routing the cables.

Connecting Power Cables

The X10DRU-i+ has a 4-pin primary power supply connector designated "JPW1" for connection to the power supply. Connect the appropriate connector from the power supply to JPW1 to supply power to the serverboard. See the Connector Definitions section in this chapter for power connector pin definitions.

Connecting the Control Panel

JF1 contains header pins for the front control panel connectors. All JF1 wires have been bundled into single keyed ribbon cable to simplify their connection. The red wire in the ribbon cable plugs into pin 1 of JF1. Connect the other end of the cable to the Control Panel printed circuit board, located just behind the system status LEDs in the chassis.

See the Connector Definitions section in this chapter for details and pin descriptions of JF1.

5-4 I/O Ports

The I/O ports at the rear of the server are pictured below..

Figure 5-2. Rear Panel I/O Ports

  1. Back Panel USB 3.0 Port 0
  2. Back Panel USB 3.0 Port 1
  3. BMC dedicated LAN
  4. COM Port 1 (Turquoise)
  5. UID Button/UID LED (LED1)
  6. Back Panel VGA (Blue)

LAN Ports

The serverboard does not provide LAN ports directly. The server includes two or four LAN ports, depending on the server model, using a pre-installed Ultra riser card (expansion card). See Section 1-1 for details.

5-5 Installing Memory

Note: Check the Supermicro web site for recommended memory modules.

CAUTION

Exercise extreme care when installing or removing DIMM modules to prevent any possible damage.

Installing DIMMs

  1. Insert the desired number of DIMMs into the memory slots, starting with slot DIMMA1.
  2. Push the release tabs outwards on both ends of the DIMM slot to unlock it.
  3. Align the key on the DIMM module with the receptive point on the slot.
  4. Use two thumbs together to press on both ends of the module straight down into the slot until the module snaps into place.
  5. Press the release tabs to the lock positions to secure the DIMM module into the slot. See Figure 5-3.

Supermicro SuperServer 6018U-TRTP+ - Installing DIMMs - 1

text_image Release Tab Socket Key Release Tab

Figure 5-3. Installing DIMM into Slot

Memory Support

The server features 24 DIMM slots that can support up to 3 TB of Load Reduction (LRDIMM) or up to 768GB of Registered (RDIMM)/Non-volatile (NV-DIMM) ECC DDR4-2400/2133/1866/1600/1333 SDRAM or LRDIMM type memory. For the latest memory updates, efer to the Supermicro website at www.supermicro.com/products/motherboard.

Processor & Memory Module Population Configuration

For memory to work properly, follow the tables below for memory installation.

Processors and their Corresponding Memory Modules
CPU# Corresponding DIMM Modules
(CPU 1) P1-DIMM A1B1 C1D1 A2B2 C2D2 A3B3 C3D3
(CPU 2) P2-DIMM E1F1 G1H1 E2F2 G2H2 E3F3 G3H3

Caution: For the memory to work properly, please install DIMMs of the same type and speed. Mixing of DIMMs of different types or speeds is not allowed.

Populating DDR4 Memory Modules

Populating RDIMM/LRDIMM DDR4 Memory Modules
TypeRanks Per DIMM and Data WidthDIMM Capacity (GB)Speed (MT/s); Voltage (V); Slots per Channel (SPC) and DIMMs per Channel (DPC)
3 Slots per Channel
1 DPC 2 DPC 3 DPC
E5-2600 V3 E5-2600 V4 E5-2600 V3 E5-2600 V4E5-2600 V4
4 Gb 8Gb 1.2 V1.2 V 1.2 V 1.2 V1.2 V 1.2 V
RDIMMSRx48 GB16 GB213324001866213316001600
RDIMMSRx84 GB8 GB213324001866213316001600
RDIMMDRx88 GB16 GB213324001866213316001600
RDIMMDRx416 GB32 GB213324001866213316001600
LRDIMMQRx432 GB64 GB213324002133240016001866
LRDIMM 3DS8Rx4 64GB128 GB213324002133240016001866

5-6 Serverboard Details

Supermicro SuperServer 6018U-TRTP+ - 5-6 Serverboard Details - 1

text_image COM1 USB 04(13.0) VGA UDP2 LED1 IPMB1 BMC_HB_LED1 IPMI_CAN SXB1A SXB2 CPU2_PORT1 CPU2_PORT0 SJB7 SJB8 SJB9 SJB10 JPN52 JBT10 JBAT10 SXB3A CPU1_PORT1 SXB3_1 CPU1_PORT3A CPU1_PORT3A CPU2_PORT3A CPU2_PORT2A CPU2_PORT2A PCH SP1 SXB3B SXB3_2 SXB3C SXB3C SXB3C SXB3C SXB3C SXB3C SXB3C SXB3C SXB3C SXB3C SXB3C SXB3C SXB3C SXB3C SXB3C SXB3C SXB3C SXB3C SXB3C SXB3C SXB3D SXB3D-3 SXB3D-3~IJP0 I-SATAA0-3 I-SATAA0-3~IJP0 I-SATAA4 I-SATAA4-600-PP1 I-SATAA4-600-PP1 I-SATAA4-600-PP1 I-SATAA4-600-PP1 I-SATAA4-600-PP1 I-SATAA4-600-PP1 I-SATAA4-600-PP1 I-SATAA4-600-PP1 I-SATAA4-650-UPW2 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 PSU2 PSU1 ICPW'1 BP PWR21 BP PWR1 GPU PWR1 FWZ1 FWZ2 FWZ1 L996 L995 SPR02 SUPER X10DRU-i+ Rev. 1.01 CPU2 CPU1 CLOSE: IJ0 LED_C1 ED_C2 ED_C3 ED_D1 ED_D2 ED_D3 ED_D4 ED_D5 ED_D6 ED_D7 ED_D8 ED_D9 ED_A0 ED_A1 ED_A2 ED_A3 ED_A4 ED_A5 ED_A6 ED_A7 ED_A8 ED_A9 ED_A10 ED_A11 ED_A12 ED_A13 ED_A14 ED_A15 ED_A16 ED_A17 ED_A18 ED_A19 ED_A20 ED_A21 ED_A22 ED_A23 ED_A24 ED_A25 ED_A26 ED_A27 ED_A28 ED_A29 ED_A30 ED_A31 ED_A32 ED_A33 ED_A34 ED_A35 ED_A36 ED_A37 ED_A38 ED_A39 ED_A40 ED_A41 ED_A42 ED_A43 ED_A44 ED_A45 ED_A46 ED_A47 ED_A48 ED_A49 ED_A50 ED_A51 ED_A52 ED_A53 ED_A54 ED_A55 ED_A56 ED_A57 ED_A58 ED_A59 ED_A60 ED_A61 ED_A62 ED_A63 ED_A64 ED_A65 ED_A66 ED_A67 ED_A68 ED_A69 ED_A70 ED_A71 ED_A72 ED_A73 ED_A74 ED_A75 ED_A76 ED_A77 ED_A78 ED_A79 ED_A80 ED_A81 ED_A82 ED_A83 ED_A84 ED_A85 ED_A86 ED_A87 ED_A88 ED_A89 ED_A90 ED_A91 ED_A92 ED_A93 ED_A94 ED_A95 ED_A96 ED_A97 ED_A98 ED_A99 ED_A100

Figure 5-4. SUPER X10DRU-i+ Layout

Notes

  • "■" indicates the location of "Pin 1".
  • Jumpers/LEDs not indicated are for testing purposes only. Also, components that are not documented in this manual are reserved for internal use only.

X10DRU-i+ Quick Reference

Jumper Description Default Setting

JBT1 Clear Onboard CMOS Battery See Section 5-8
JPB1 BMC Enable Pins 1-2 (Enabled)
JPG1 VGA Enable Pins 1-2 (Enabled)
JPME2 ME Manufacturing Mode Select Pins 1-2 (Normal)
JPP0/JTAG SCAN CPU1 JTAG Scan EnablePins 1-4 (Includes CPU2, 2-3: isolates CPU1)
JPP1/JTAG SCAN CPU2 JTAG Scan EnablePins 1-4 (Includes CPU1, 2-3: isolates CPU2)
JWD1 Watch Dog Timer Enable Pins 1-2 (Reset)

Connectors Description

BP PWR1/2 Backplane power connectors
COM1 COM Port1
Fan1-8CPU/System Fan Headers
GPU PWR1-PWR48-pin Power Connectors (1-4) for GPUs
JF1Front Control Panel Header
JF24-pin Power Connector for LAN 3/4 LED
JL1Chassis Intrusion Header
JIPMB14-pin External BMC I2C Header (for an IPMI card)
JSD1/JSD2SATA DOM (Device on Module) Power Connectors
JTPM1TPM (Trusted Platform Module)/Port 80 Header
IPMI_LANDedicated IPMI LAN Support (by the ASpeed controller)
PSU1/PSU2Power Supply Unit 1/Unit 2 Headers
I-SATA0~3, 4, 5SATA 3.0 Ports (Intel PCH)
S-SATA 0~3SATA 3.0 Ports (Intel SCU)
SXB1A/1B/1CSMCI-proprietary PCI-E Slot used for WIO-Left Devices (supported by CPU2)
SXB2SMCI-proprietary PCI-E 3.0x8 Slot for WIO-Right Devices or Add-on Cards (supported by CPU2)
SXB3A/3B/3CSMCI-proprietary PCI-E Slot for Ultra Riser Devices (supported by CPU1)
I-SGPIO2Serial Link General Purpose I/O (SGPIO) header (for S-SATA ports)
USB 0/1 (3.0)Rear USB 3.0 Ports
USB 2 (3.0)Type A USB 3.0 Header
USB 3/4 (3.0)Front Accessible USB 3.0 Headers
VGAVGA Port

LED Description (State) Status

BMC_HB_LED1 BMC Heartbeat LED (Green: Blinking) BMC Normal
LED1 Rear UID LED (Blue: On) Unit Identified
HDD_LED1 HDD Heartbeat LED (Blinking) HDD Normal
LED2 Onboard PWR LED (On) System Power On
LED_A1-A3Memory Fault Detect LED for DIMM slots A1-A3: (Red: On)Memory Error(s)
LED_B1-B3Memory Fault Detect LED for DIMM slots B1-B3: (Red: On)Memory Error(s)
LED_C1-C3Memory Fault Detect LED for DIMM slots C1-C3: (Red: On)Memory Error(s)
LED_D1-D3Memory Fault Detect LED for DIMM slots D1-D3: (Red: On)Memory Error(s)
LED_F1-F3 Memory Fault Detect LED for DIMM slots F1-F3: (Red: On) Memory Error(s)
LED_G1-G3Memory Fault Detect LED for DIMM slots G1-G3: (Red: On)Memory Error(s)
LED_H1-H3Memory Fault Detect LED for DIMM slots H1-H3: (Red: On)Memory Error(s)

5-7 Connector Definitions

Power Connectors

The X10DRU-i+ motherboard supports the following power configurations:

  • Two proprietary main power supply units (PSU1: for CPU1 platform support, PSU2: for CPU2 platform support)
  • Two backplane power-connector units (each unit comprised of two 8-pin power connectors) for backplane device use (BP PWR1: CPU1 platform support, BP PWR2: for CPU2 platform support)
    • Four 8-pin power-connectors (GPU PWR1-4) used for GPU devices
    • One 4-pin power connector (JF2) used for LAN 3/4 LED

Caution: To provide adequate power to your system and to avoid damaging the power supply or the motherboard, be sure to connect all power connectors mentioned above to the power supply when using the devices mentioned. Failure in doing so may void the manufacturer warranty on your power supply and motherboard.

8-pin GPU PWRPin Definitions
PinsDefinition
1 through 3 Ground
4 through 8 +12V

NMI Button

The non-maskable interrupt button header is located on pins 19 and 20 of JF1. Refer to the table on the right for pin definitions.

NMI ButtonPin Definitions (JF1)
Pin#Definition
19Control
20Ground

Power LED

The Power LED connection is located on pins 15 and 16 of JF1. Refer to the table on the right for pin definitions.

Power LEDPin Definitions (JF1)
Pin#Definition
15 3.3V
16 PWR LED

HDD LED/UID Switch

The HDD LED/UID switch connections are located on pins 13/14 of JF1. Attach an LED cable to display HDD activity. Attach a cable to pin 13 to use UID button. See the table on the right for pin definitions.

HDD/UID SwitchPin Definitions (JF1)
Pin#Definition
13 UID Switch
14 HDD Active

NIC1/NIC2 LED

The NIC (Network Interface Controller) LED connections for GLAN port 1 are located on pins 11 and 12 of JF1, and the LED connection for GLAN Port 2 are on pins 9 and 10. Attach the NIC LED cables here to display network activity. Refer to the table on the right for pin definitions.

Note: The NIC LED connections for 10G_LAN Ports 3/4 is located on LED1.

GLAN 1/2 LEDPin Definitions (JF1)
Pin#Definition
9 NIC2 Activity LED
10 NIC2 Link LED
11 NIC1 Activity LED
12 NIC1 Link LED

Overheat (OH)/Fan Fail/PWR Fail/UID LED

Connect an LED cable to pins 7 and 8 of Front Control Panel to use the Overheat/Fan Fail/Power Fail and UID LED connections. The Red LED on pin 8 provides warnings of overheat, fan failure or power failure. The Blue LED on pin 7 works as the front panel UID LED indicator. Refer to the table on the right for pin definitions.

OH/Fan Fail/ PWR Fail/Blue_UIDLED Pin Definitions (JF1)
Pin#Definition
7 Blue_UID LED
8 OH/Fan Fail/Power Fail
OH/Fan Fail/PWR FailLED Status (Red LED)
StateDefinition
Off Normal
On Overheat
Flashing Fan Fail

Power Fail LED

The Power Fail LED connection is located on pins 5 and 6 of JF1. Refer to the table on the right for pin definitions.

PWR Fail LEDPin Definitions (JF1)
Pin#Definition
5 3.3V
6 PWR Supply Fail

Reset Button

The Reset Button connection is located on pins 3 and 4 of JF1. Attach it to the hardware reset switch on the computer case. Refer to the table on the right for pin definitions.

Power Button

The Power Button connection is located on pins 1 and 2 of JF1. Momentarily contacting both pins will power on/off the system. This button can also be configured to function as a suspend button (see the Power Button Mode setting in BIOS). To turn off the power when set to suspend mode, depress the button for at least 4 seconds. Refer to the table on the right for pin definitions.

Fan Headers

The serverboard has eight system/CPU fan headers (Fan 1\~Fan 8). All are 4-pin fans headers, which are backward compatible with traditional 3-pin fans. Fan speed control is available for 4-pin fans only. The fan speeds are controlled by IPMI. See the table on the right for pin definitions.

Chassis Intrusion

A Chassis Intrusion header is located at JL1. Attach an appropriate cable from the chassis to inform you of a chassis intrusion when the chassis is opened.

Reset ButtonPin Definitions (JF1)
Pin#Definition
3 Reset
4 Ground
Power ButtonPin Definitions (JF1)
Pin#Definition
1 Signal
2 Ground
Fan HeaderPin Definitions
Pin#Definition
1 Ground
2 +12V
3 Tachometer
4 Pulse Width Modulation(PWM)
Chassis Intrusion Pin Definitions
Pin#Definition
1Intrusion Input
2Ground

Internal Speaker

The Internal Speaker, located at SP1, can be used to provide audible indications for various beep codes. See the table on the right for pin definitions.

Internal SpeakerPin Definition
Pin#Definitions
Pin 1 Pos. (+) BeepIn
Pin 2 Neg. (-) AlarmSpeaker

TPM Header/Port 80

A Trusted Platform Module/Port 80 header is located at JTPM1 to provide TPM support and Port 80 connection. Use this header to enhance system performance and data security. See the table on the right for pin definitions.

TPM/Port 80 HeaderPin Definitions
Pin #Definition Pin #Definition
1 LCLK 2 GND
3 LFRAME# 4 < (KEY)>
5 LRESET# 6 +5V (X)
7 LAD 3 8 LAD 2
9 +3.3V 10 LAD1
11 LAD0 12 GND
13 SMB_CLK4 14 SMB_DAT4
15 +3V_DUAL 16 SERRQ
17 GND18CLKRUN# (X)
19 LPCPD#20LDRQ# (X)

I-SGPIO2 Header

A Serial-Link General Purpose Input/Output header (I-SGPIO2) supports onboard I-SATA 4/5. See the table on the right for pin definitions.

I-SGPIOPin Definitions
Pin#DefinitionPinDefinition
1 NC2 NC
3 Ground4 Data
5 Load6 Ground
7 Clock8 N

NC = No Connection

DOM Power Connectors

Two power connectors for SATA DOM (Disk On Module) devices are located at JSD1 and JSD2. These connectors are used with Supermciro SuperDOMs to provide backward-compatible power support to non-Supermicro SATADOMs that require external power supply.

DOM PWRPin Definitions
Pin#Definition
1 +5V
2 Ground
3 Ground

Unit Identifier Buttons/UID LED Indicators

A rear unit identifier button (JUIDB2) is located next to the COM port. The connection for the front UID button is located on pin 13 of JF1. The rear UID LED (LED1) is located next to the rear UID button, and the front UID LED connection is located on pin 7 of JF1. When you press the rear UID button, both front and rear UID LED indicators will be turned on. Press the UID button again to turn off the LEDs. The UID indicators provide easy identification of a system unit that may be in need of service.

Note: UID can also be triggered via IPMI. For more information on IPMI, please refer to the IPMI User's Guide posted on our website.

UID Button
Pin#Definition
1 Ground
2 Ground
3 Button In
4 Button In
UID LEDStatus
Color/State Status
Blue: On Unit Identified

Universal Serial Bus (USB)

Two USB 3.0 ports (USB 0/1) are located on the rear I/O panel. A Type A USB connector (USB 2), and a USB header with two USB connections (USB 3/4) provide onboard three USB 3.0 connections for front access (cables not included). See the tables below for pin definitions.

USB 3.0 Port (USB0/1, 2)Pin Definitions
Pin#DefinitionPin#Definition
1 +5V5 +5V
2 USB_PN16 USB_PN0
3 USB_PP17 USB_PP0
4 Ground8 Ground
USB 3.0 Header (USB 3/4)Pin Definitions
Pin#Description Pin# Description
1 USB3.0_Front_VCC
2 USB3_RE_RXN619 USB3.0_Front_VCC
3 USB3_RE_RXP618 USB3_RE_RXN5
4 Ground 17 USB3_RE_RXP5
5 USB3_RE_TXN616 Ground
6 USB3_RE_TXP615 USB3_RE_TXN5
7 Ground 14 USB3_RE_TXP5
8 USB2_N813 Ground
9 USB2_P812 USB2_N9
10Ground 11 USB2_P9

5-9 Jumper Settings

Explanation of Jumpers

To modify the operation of the serverboard, jumpers can be used to choose between optional settings. Jumpers create shorts between two pins to change the function of the connector. Pin 1 is identified with a square solder pad on the printed circuit board. See the diagram at right for an example of jumping pins 1 and 2. Refer to the serverboard layout page for jumper locations.

Note: On two-pin jumpers, "Closed" means the jumper is on and "Open" means the jumper is off the pins.

Supermicro SuperServer 6018U-TRTP+ - Explanation of Jumpers - 1

CMOS Clear

JBT1 is used to clear CMOS and will also clear any passwords. Instead of pins, this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS.

To clear CMOS

  1. First power down the system and unplug the power cord(s).
  2. With the power disconnected, short the CMOS pads with a metal object such as a small screwdriver.
  3. Remove the screwdriver (or shorting device).
  4. Reconnect the power cord(s) and power on the system.

Note: Do not use the PW_ON connector to clear CMOS.

VGA Enable/Disable

JPG1 allows you to enable or disable the onboard VGA port. The default position is on pins 1 and 2 to enable VGA. See the table on the right for jumper settings. The default setting is enabled.

VGA Enable/Disable Jumper Settings
Jumper SettingDefinition
Pins 1-2 Enabled
Pins 2-3 Disabled

Watch Dog Enable/Disable

JWD1 controls the Watch Dog function. Watch Dog is a system monitor that can reboot the system when a software application “hangs”. Pins 1-2 will cause WD to reset the system if an application hangs. Pins 2-3 will generate a non-maskable interrupt signal for the application that has hung. See the table on the right for jumper settings. Watch Dog must also be enabled in BIOS.

Watch DogJumper Settings
Jumper SettingDefinition
Pins 1-2 Reset
Pins 2-3 NMI
Open Disabled

BMC Enable

Jumper JPB1 allows you to enable the embedded onboard BMC (Baseboard Management) controller to provide IPMI 2.0 support on the motherboard. See the table on the right for jumper settings.

BMC EnableJumper Settings
Jumper SettingDefinition
Pins 1-2 BMC Enable
Pins 2-3 Normal

ME Manufacturing Mode Select

Close pin 2 and pin 3 of jumper JPME2 to bypass SPI flash security and force the system to operate in the Manufacturer (ME) mode, allowing the user to flash the system firmware from a host server for system setting modifications. See the table on the right for jumper settings.

ME Mode SelectJumper Settings
Jumper SettingDefinition
Pins 1-2 Normal
Pins 2-3 Manufacture Mode

5-10 Onboard Indicators

IPMI Dedicated LAN LEDs

A dedicated IPMI LAN port is located on the rear I/O panel. The amber LED on the right indicates activity, while the LED on the left indicates the speed of the connection. See the tables at right for more information.

IPMI LAN Activity IndicatorLED Settings
ColorStatusDefinition
Amber Flashing Active
IPMI LAN Speed LED
LED ColorDefinition
Off 10 Mbps, or No Connection
Green 100 Mbps
Amber 1 Gbps

HDD Heartbeat LED

An HDD heartbeat LED is located next to the JF1 header. When this green LED is blinking, HDD devices are functioning normally. See the table at right for more information.

HDD Heartbeat LED States
Color/StateDefinition
Green: BlinkingHDD: Normal

Onboard Power LED

An Onboard Power LED is located at LE2 on the motherboard. When this LED is on, the system is on. Be sure to turn off the system and unplug the power cord before removing or installing components. See the tables at right for more information.

Onboard PWR LED IndicatorLED States
LED ColorDefinition
Off SystemOff (PWR cable not connected)
Green System On
Green:FlashingQuicklyACPI S1 State

BMC Heartbeat LED

A BMC Heartbeat LED is located at BMC_HB_LED1. When this LED is blinking, BMC is functioning normally.

BMC Heartbeat LED Status
Color/StateDefinition
Green:BlinkingBMC: Normal

5-11 SATA Ports

Ten SATA 3.0 ports are located on the serverboard. Six ports (I-SATA 0\~3, 4, 5) are supported by the Intel PCH C612. I-SATA 4 and I-SATA 5 also support self-powered Supermcro SuperDOM (Device-on-Module) devices or any 3rd-party SATA DOM devices that use external power via JSD1 and JSD2. The other four SATA ports (S-SATA 0\~3) are supported by the Intel SCU See the table on the right for pin definitions.

5.12 Microsoft Windows OS Installation

If you will be using RAID, you must configure RAID settings before installing the Windows OS and the RAID driver. Refer to the RAID Configuration User Guides posted on our website at www.supermicro.com/support/manuals.

Installing the OS

  1. Create a method to access the MS Windows installation ISO file. That might be a DVD, perhaps using an external USB/SATA DVD drive, or a USB flash drive, or the IPMI KVM console.
  2. Retrieve the proper RST/RSTe driver. Go to the Supermicro web page for your motherboard and click on "Download the Latest Drivers and Utilities", select the proper driver, and copy it to a USB flash drive.
  3. Boot from a bootable device with Windows OS installation. You can see a bootable device list by pressing F11 during the system startup.

Supermicro SuperServer 6018U-TRTP+ - Installing the OS - 1

text_image Please select boot device: ATEN Virtual CDROM YSOJ → IPMI virtual drive (Legacy) ASUS SDRW-08D2S-U F601 → USB DVD device (Legacy) USB FLASH DRIVE PMAP → USB flash drive with OS installation (Legacy) IBA 40-10G Slot 1900 v1060 → PXE boot (Legacy) UEFI: ATEN Virtual CDROM YSOJ → IPMI virtual drive (UEFI) UEFI: ASUS SDRW-08D2S-U F601 → USB DVD device (UEFI) UEFI: Built-in EFI Shell Enter Setup ↑ and ↓ to move selection ENTER to select boot device ESC to boot using defaults

Figure 5-5. Select Boot Device

  1. During Windows Setup, continue to the dialog where you select the drives on which to install Windows. If the disk you want to use is not listed, click on "Load driver" link at the bottom left corner.

Supermicro SuperServer 6018U-TRTP+ - Installing the OS - 2

text_image Where do you want to install Windows? Name Total size Free space Type Refresh Delete Format New Load driver Extend We couldn't find any drives. To get a storage driver, click Load driver. Next

Figure 5-6. Load Driver Link

To load the driver, browse the USB flash drive for the proper driver files.

  • For RAID, choose the SATA/sSATA RAID driver indicated then choose the storage drive on which you want to install it.
  • For non-RAID, choose the SATA/sSATA AHCI driver indicated then choose the storage drive on which you want to install it.

  • Once all devices are specified, continue with the installation.

  • After the Windows OS installation has completed, the system will automatically reboot multiple times.

5-13 Installing Software

The Supermicro website contains drivers and utilities for your system at https://www.supermicro.com/wdl/driver. Some of these must be installed, such as the chipset driver.

After accessing the website, go into the CDR_Images (in the parent directory of the above link) and locate the ISO file for your motherboard. Download this file to a USB flash drive or a DVD. (You may also use a utility to extract the ISO file if preferred.)

Another option is to go to the Supermicro website at http://www.supermicro.com/products/. Find the product page for your motherboard, and "Download the Latest Drivers and Utilities".

Insert the flash drive or disk and the screenshot shown below should appear.

Supermicro SuperServer 6018U-TRTP+ - 5-13 Installing Software - 1

text_image SUPERMICRO X10DRU-i+ Motherboard Drivers & Tools (Win7) SupersMCRC Drivers & Tools Intel C610 Chipset X10DRU-i+ SUPERMICRO Computer Inc. Intel Chipset INF files Microsoft .Net Framework (Optional) ASPEED Graphics Driver Intel Rapid Storage Technology Enterprise Intel USB 3.0 Drivers Intel PRO Network Connections Drivers Intel Management Engine SUPERMICRO SuperDoctor 5 Build driver diskettes and manuals Browse CD Auto Start Up Next Time For more information, please visit SUPERMICRO's web site.

Figure 5-7. Driver Installation Display Screen

Note: Click the icons showing a hand writing on paper to view the readme files for each item. Click the computer icons to the right of these items to install each item (from top to the bottom) one at a time. After installing each item, you must re-boot the system before moving on to the next item on the list. The bottom icon with a CD on it allows you to view the entire contents.

SuperDoctor® 5

The Supermicro SuperDoctor 5 is a program that functions in a command-line or web-based interface for Windows and Linux operating systems. The program monitors such system health information as CPU temperature, system voltages, system power consumption, fan speed, and provides alerts via email or Simple Network Management Protocol (SNMP).

SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize your system monitoring needs. With SuperDoctor 5 Management Server (SSM Server), you can remotely control power on/off and reset chassis intrusion for multiple systems with SuperDoctor 5 or IPMI. SuperDoctor 5 Management Server monitors HTTP, FTP, and SMTP services to optimize the efficiency of your operation.

Supermicro SuperServer 6018U-TRTP+ - SuperDoctor® 5 - 1

text_image SuperDoctor 5 Voltage 10V 20V 30V 40V 50V 60V 70V 80V 90V 100V 110V 120V 130V 140V 150V 160V 170V 180V 190V 200V 210V 220V 230V 240V 250V 260V 270V 280V 290V 300V 310V 320V 330V 340V 350V 360V 370V 380V 390V 400V 410V 420V 430V 440V 450V 460V 470V 480V 490V 500V 510V 520V 530V 540V 550V 560V 570V 580V 590V 600V 610V 620V 630V 640V 650V 660V 670V 680V 690V 700V 710V 720V 730V 740V 750V 760V 770V 780V 790V 800V 810V 820V 830V 840V 850V 860V 870V 880V 890V 900V 910V 920V 930V 940V 950V 960V 970V 980V 990V 1000V

Figure 5-8. SuperDoctor 5 Interface Display Screen (Health Information)

Note: The SuperDoctor 5 program and User's Manual can be downloaded from the Supermicro web site at https://www.supermicro.com/products/nfo/sms_sd5.cfm.

5.14 BMC

The motherboard provides remote access, monitoring and management through the baseboard management controller (BMC) and other management controllers distributed among different system modules. There are several BIOS settings that are related to BMC. For general documentation and information on BMC, visit our website at:

www.supermicro.com/en/solutions/management-software/bmc-resources

BMC ADMIN User Password

For security, each system is assigned a unique default BMC password for the ADMIN user. This can be found on a sticker on the chassis and a sticker on the motherboard. The sticker also displays the BMC MAC address.

Note: Only later models include this sticker and pull-out tray.

Supermicro SuperServer 6018U-TRTP+ - BMC ADMIN User Password - 1

text_image BMC AC1F6BC PWD SUOKJ

Figure 5-9. BMC Password Label

Supermicro SuperServer 6018U-TRTP+ - BMC ADMIN User Password - 2

text_image This graphic is for illustration Your system looks slightly diff

Figure 5-10. Location of the BMC Password Label
(On later models only.)

5-15 Onboard Battery

Please handle used batteries carefully. Do not damage the battery in any way; a damaged battery may release hazardous materials into the environment. Do not discard a used battery in the garbage or a public landfill. Please comply with the regulations set up by your local hazardous waste management agency to dispose of your used battery properly.

Supermicro SuperServer 6018U-TRTP+ - 5-15 Onboard Battery - 1

text_image LITHIUM BATTERY BATTERY HOLDER

Figure 5-11. Installing the Onboard Battery

Notes

Chapter 6

Advanced Chassis Setup

This chapter covers the steps required to install components and perform maintenance on the SC819UTQ-R750 chassis. The only tool required is a Phillips screwdriver.

Your system may require the installation of processors, memory, drives or expansion cards. Other procedures presented in this chapter are for maintenance or replacement.

Supermicro SuperServer 6018U-TRTP+ - Advanced Chassis Setup - 1

text_image Hot-Swap Drive Bays (4) Control Panel PWS1 PWS2 Power Supplies LAN Ports (2 or 4) Rear I/O Ports PCI Slots

Figure 6-1. Chassis Front and Rear Views

6-1 Static-Sensitive Devices

Electrostatic Discharge (ESD) can damage electronic components. To prevent damage to any printed circuit boards (PCBs), it is important to handle them very carefully.

The following measures are generally sufficient to protect your equipment from ESD damage.

Precautions

  • Use a grounded wrist strap designed to prevent static discharge.
  • Touch a grounded metal object before removing any board from its antistatic bag.
  • Handle a board by its edges only; do not touch its components, peripheral chips, memory modules or gold contacts.
  • When handling chips or modules, avoid touching their pins.

  • Put the serverboard, add-on cards and peripherals back into their antistatic bags when not in use.

  • For grounding purposes, make sure your computer chassis provides excellent conductivity between the power supply, the case, the mounting fasteners and the serverboard.

6-2 Removing the Power

  1. Use the operating system to power down the system, following the on-screen prompts.

  2. After the system has completely shut-down, carefully grasp the head of the power cord and gently pull it out of the back of the power supply. If your system has dual power supplies, remove the cords from both power supplies.

  3. Disconnect the cord from the power strip or wall outlet.

6-3 Control Panel

The control panel (located on the front of the chassis) must be connected to the JF1 connector on the serverboard to provide you with system status indications. A ribbon cable has bundled these wires together to simplify the connection. Connect the cable from JF1 on the serverboard to the appropriate header on the Control Panel PCB (printed circuit board). Make sure the red wire plugs into pin 1 on both connectors. Pull all excess cabling out of the airflow path.

The control panel LEDs inform you of system status. See "Chapter 3: System Interface" for details on the LEDs and the control panel buttons. Details on JF1 can be found in "Chapter 5: Advanced Serverboard Installation."

6-4 Chassis Cover

Supermicro SuperServer 6018U-TRTP+ - 6-4 Chassis Cover - 1

text_image Release Buttons

6-2. Removing the Chassis Cover

Before operating the system for the first time, remove the protective film over the cover of the chassis, in order to allow for proper ventilation and cooling.

Removing the Chassis Cover and Protective Film

  1. Peel off the protective film covering the top cover and the top of the chassis
  2. Press the two release buttons and slide the cover toward the rear.
  3. Lift the top cover up.

Check that all ventilation openings on the top cover and the top of the chassis are clear and unobstructed.

6-5 Installing Drives

Drive bays are accessible from the front of the chassis without removing the chassis cover or powering down the system. The hard disk drives are mounted in drive carriers to simplify their installation and removal from the chassis. These carriers also help promote proper airflow for the drive bays. For this reason, even carriers without drives installed must remain in the chassis during system operation.

Removing Hard Drive Carriers from the Chassis

  1. Press the release button on the drive carrier. This extends the drive carrier handle.
  2. Use the handle to pull the drive carrier out of the chassis.

Supermicro SuperServer 6018U-TRTP+ - Removing Hard Drive Carriers from the Chassis - 1

text_image Technical diagram showing server rack connection with labeled components and a zoomed-in view of the internal structure.

Figure 6-3. Removing a Hard Drive Carrier

Supermicro SuperServer 6018U-TRTP+ - Removing Hard Drive Carriers from the Chassis - 2

text_image Dummy Drive Hard Drive Carrier

Figure 6-4. Removing a Dummy Drive from the Drive Carrier

Installing a Hard Drive into a Drive Carrier

  1. Remove the screws securing the dummy drive to the hard drive carrier, and remove the dummy.
  2. Insert a hard drive into the carrier with the PCB side facing down and the connector end toward the rear of the carrier. Align the hard drive in the carrier so that the mounting holes of the carrier are aligned with the mounting holes of the drive. Note that there are holes in the carrier which are marked "SATA" to aid in correct installation.
  3. Secure the drive to the carrier with the screws. Use the M3 flat-head screws included in the HDD bag of your accessory box. Note: The screws used to secure the dummy drive to the carrier cannot be used to secure the hard drive.
  4. Insert the hard drive and carrier into its bay, keeping the carrier oriented so that the release button is on the right. When the carrier reaches the rear of the drive bay, the handle will retract.
  5. Using your thumb, push against the upper part of the hard drive handle. Push the hard drive into the hard drive bay as illustrated below, until the hard drive clicks into the locked position.

Caution: Except for short periods of time (swapping hard drives), do not operate the server with the hard drive carriers removed.

Enterprise level hard disk drives are recommended for use in Supermicro chassis and servers. For information on recommended HDDs, visit the Supermicro Web site at http://www.supermicro.com/products/nfo/storage.cfm

6-6 Installing Expansion Cards

The system accepts two full height full-length expansion cards or one double width GPU, and one low profile card, mounted on a riser card and riser bracket. There is also an internal expansion slot in the center of the chassis. Additional fans are recommended; see Section 6-7.

Installing a Full Height or GPU Expansion Card

  1. Power down the system as described in section 6-2 and remove the cover.
  2. Remove the bracket and sections of the chassis in the rear. Small screwdriver icons are etched into the chassis pieces to help identify which screws must be removed.

Supermicro SuperServer 6018U-TRTP+ - Installing a Full Height or GPU Expansion Card - 1

natural_image Technical line drawing of a server rack with internal components and mounting brackets (no text or symbols)

Figure 6-5. Riser Card Bracket and Expansion Slots

Supermicro SuperServer 6018U-TRTP+ - Installing a Full Height or GPU Expansion Card - 2

text_image Icons

Figure 6-6. Example of Screwdriver Icons

  1. If necessary, attach the riser card to the riser card bracket using screws.

  2. Insert the expansion card into a slot on the riser card while aligning the expansion card backplate with the open slot in the rear of the chassis.

  3. Insert the riser card into the motherboard expansion slot while aligning the riser card bracket with the rear of the chassis. Secure the bracket with screws.

  4. Connect the GPU power cables to the power connector.

Supermicro SuperServer 6018U-TRTP+ - Installing a Full Height or GPU Expansion Card - 3

text_image 8-pin GPU Power Connector Expansion Cards Internal Expansion Card

Figure 6-7. Expansion Cards

Internal Expansion Card

The pre-installed expansion card that holds your LAN ports also offers another internal low profile card slot for Supermicro SAS only.

  1. Remove the cover and find the slot in the center of the chassis near the power supply modules.

  2. Insert your SAS expansion card.

6-7 System Cooling

Four to eight 4-cm counter-rotating fans provide the cooling for the system. Each fan unit is actually made up of two fans joined back-to-back, which rotate in opposite directions. This counter-rotating action generates exceptional airflow and works to dampen vibration levels. Four compound fans come stock with the server, and four more can be added.

Make sure the chassis top cover makes a good seal so the cooling air circulates properly through the chassis.

Optional Fans

Additional fans are recommended when expansion cards are added. This table shows the fan positions.

Recommended Optional Fans
Expansion Card Location FanPosition
PCIe x16 Slot 1 FAN 5, FAN 8
PCIe x16 Slot 2 FAN 5, FAN 8
PCIe x8 LP FAN 5
PCIe x8 Internal LP FAN 4

Supermicro SuperServer 6018U-TRTP+ - Optional Fans - 1

natural_image Isometric technical diagram of a server rack with internal components and a highlighted red region (no text or labels)

Figure 6-8. Installing a Fan

System Fan Replacement

Fan speed is controlled by IPMI depending on the system temperature. If a fan fails, the remaining fans will ramp up to full speed. The system can continue to run with a failed fan. Replace any failed fan at your earliest convenience with the same model. Failed fans can be identified through the BIOS. The fan numbers are printed on the floor of the chassis.

Changing a System Fan

  1. If necessary, open the chassis while the system is running to determine which fan has failed. Never run the server for an extended period of time with the chassis cover open.
  2. Unplug the fan cable from the serverboard and remove the failed fan from the chassis.
  3. Replace the failed fan with an identical 4cm fan, available from Supermicro.
  4. Push the new fan into the vacant space in the housing while making sure the arrows on the top of the fan (indicating air direction) point in the same direction as the arrows on the other fans.
  5. Reposition the fan housing back over the two mounting posts in the system, then reconnect the fan wires to the same fan headers on the serverboard.
  6. Power up the system and check that the fan is working properly and that the LED on the control panel has turned off. Finish by replacing the chassis cover.

Supermicro SuperServer 6018U-TRTP+ - Changing a System Fan - 1

natural_image Technical line drawing of a mechanical assembly with multiple circular components and mounting brackets (no text or symbols)

6-9. Fans in Housing

Air Shroud

Air shrouds concentrate airflow to maximize fan efficiency. Install an air shroud for each CPU. Any desired expansion cards should be installed before the air shroud.

Installing an Air Shroud

- Place the air shroud over the serverboard, as shown below. It sits behind the system fans and goes over the top of the CPU heatsink and nearby components.

Supermicro SuperServer 6018U-TRTP+ - Installing an Air Shroud - 1

natural_image Isometric technical diagram of a server rack with internal components and a connector (no text or labels)

Supermicro SuperServer 6018U-TRTP+ - Installing an Air Shroud - 2

text_image Shroud

6-10. Installing the Air Shroud

6-8 Power Supply

The server includes two redundant, hot-plug 750 watt power supply modules. They automatically sense the input voltage between 100v to 240v, and operate at that voltage. An amber light on the power supply is illuminated when the power is switched off. An green light indicates that the power supply is operating.

If either of the power supply modules fail, the other module will support the full load and allow the system to continue operation without interruption. The PWR Fail LED will illuminate and remain on until the failed unit has been replaced. Replace with the same model. Replacement units can be ordered directly from Supermicro.

Supermicro SuperServer 6018U-TRTP+ - 6-8 Power Supply - 1

natural_image Front view of a rack-mounted server chassis with multiple ports and connectors (no visible text or labels)

Figure 6-11. Removing the Power Supply

Replacing the Power Supply

  1. Unplug the AC power cord from the failed power supply module.
  2. Push in the locking tab at the back of the module to release it.
  3. Pull the unit straight out of the chassis.
  4. Insert the new unit into the chassis, pushing until it clicks.
  5. Reconnect the power cord.

6-9 Removing the Ultra Riser Card

To remove the Ultra riser card, use two hands. One hand lifts the mylar release tab and the other hand lifts at the PCI-E x8 slot at the same time. Caution: Lifting at only one of these points may cause damage to connectors on the motherboard.

Supermicro SuperServer 6018U-TRTP+ - 6-9 Removing the Ultra Riser Card - 1

text_image Mylar Lift Tab Mylar Lift Tab

Figure 6-12. Removing the Ultra Riser Card

Chapter 7

BIOS

7-1 Introduction

This chapter describes the AMI BIOS setup utility for the X10DRU-i+. It also provides the instructions on how to navigate the AMI BIOS setup utility screens. The AMI ROM BIOS is stored in a Flash EEPROM and can be easily updated.

Starting BIOS Setup Utility

To enter the AMI BIOS setup utility screens, press the key while the system is booting up.

Note: In most cases, the key is used to invoke the AMI BIOS setup screen. There are a few cases when other keys are used, such as , , etc.

Each main BIOS menu option is described in this manual. The Main BIOS setup menu screen has two main frames. The left frame displays all the options that can be configured. Grayed-out options cannot be configured. Options in blue can be configured by the user. The right frame displays the key legend. Above the key legend is an area reserved for informational text. When an option is selected in the left frame, it is highlighted in white. Often informational text will accompany it.

Note: The AMI BIOS has default informational messages built in. The manufacturer retains the option to include, omit, or change any of these informational messages.

The AMI BIOS setup utility uses a key-based navigation system called "hot keys." Most of the AMI BIOS setup utility "hot keys" can be used at any time during setup navigation. These keys include , , , , arrow keys, etc.

Note 1: Options printed in Bold are default settings.

Note 2: is used to load optimal default settings. is used to save the settings and exit the setup utility.

How To Change the Configuration Data

The configuration data that determines the system parameters may be changed by entering the AMI BIOS setup utility. This setup utility can be accessed by pressing at the appropriate time during system boot.

Note: For AMI UEFI BIOS Recovery, please refer to the UEFI BIOS Recovery User Guide posted @ http://www.supermicro.com/support/manuals/.

Starting the Setup Utility

Normally, the only visible Power-On Self-Test (POST) routine is the memory test. As the memory is being tested, press the key to enter the main menu of the AMI BIOS setup utility. From the main menu, you can access the other setup screens. An AMI BIOS identification string is displayed at the left bottom corner of the screen below the copyright message.

Caution: Do not upgrade the BIOS unless your system has a BIOS-related issue. Flashing the wrong BIOS can cause irreparable damage to the system. In no event shall the manufacturer be liable for direct, indirect, special, incidental, or consequential damage arising from a BIOS update. If you have to update the BIOS, do not shut down or reset the system while the BIOS is being updated to avoid possible boot failure.

7-2 Main Setup

When you first enter the AMI BIOS setup utility, you will enter the Main setup screen. You can always return to the Main setup screen by selecting the Main tab on the top of the screen. The Main BIOS Setup screen is shown below.

Supermicro SuperServer 6018U-TRTP+ - 7-2 Main Setup - 1

text_image Aptio Setup Utility - Copyright (C) 2014 American Megatrends, Inc. Main Advanced Event Logs IPMI Security Boot Save & Exit System Date [Wed 09/10/2014] System Time [17:15:21] Supermicro X100RU-1+ BIOS Version 1.0 Build Date 08/11/2014 Memory Information Total Memory 16384 MB Memory Speed 2133 MT/s Set the Time. Use Tab to switch between Time elements. ++: Select Screen T↓: Select Item Enter: Select +/-: Change Opt. F1: General Help F2: Previous Values F3: Optimized Defaults F4: Save & Exit ESC: Exit Version 2.17.1245. Copyright (C) 2014 American Megatrends, Inc.

The AMI BIOS Main menu displays the following information:

System Date

Use this item to change the system date. Press the key to move between fields. Enter new values through the keyboard and press . The date must be entered in MM/DD/YYYY format.

System Time

Use this item to change the system time. Press the key to move between fields. Enter new values through the keyboard and press . The time is entered in HH:MM:SS format. The time is in the 24-hour format. For example, 5:30 P.M. appears as 17:30:00.

Supermicro X10DRU-i+

BIOS Version

This item displays the version of the BIOS ROM used in this system.

Build Date

This item displays the date that the BIOS setup utility was built.

Memory Information

Total Memory

This item displays the amount of memory that is available in the system.

Memory Speed

This item displays the memory speed.

7-3 Advanced Setup Configurations

Supermicro SuperServer 6018U-TRTP+ - 7-3 Advanced Setup Configurations - 1

text_image Aptio Setup Utility - Copyright (C) 2014 American Megatrends, Inc. Main Advanced Event Logs IPMI Security Boot Save & Exit ► Boot Feature ► CPU Configuration ► Chipset Configuration ► SATA Configuration ► SSATA Configuration ► Server ME Configuration ► PCIe/PCI/PnP Configuration ► Super IO Configuration ► Serial Port Console Redirection ► ACPI Settings Boot Feature Configuration Page ++: Select Screen ↑↓: Select Item Enter: Select +/-: Change Opt. F1: General Help F2: Previous Values F3: Optimized Defaults F4: Save & Exit ESC: Exit Version 2.17.1245. Copyright (C) 2014 American Megatrends, Inc.

Select the Advanced tab to access the following submenu items.

▶Boot Features

Boot Feature

Quiet Boot

Use this item to select bootup screen display between POST messages and the OEM logo. Select Disabled to display the POST messages. Select Enabled to display the OEM logo instead of the normal POST messages. The options are Enabled and Disabled.

AddOn ROM Display Mode

Use this item to set the display mode for the Option ROM. Select Keep Current to use the current AddOn ROM Display setting. Select Force BIOS to use the Option ROM display set by the system BIOS. The options are Force BIOS and Keep Current.

Bootup Num-Lock

Use this item to set the power-on state for the Numlock key. The options are Off and On.

Wait For 'F1' If Error

Select Enabled to force the system to wait until the 'F1' key is pressed when an error occurs. The options are Disabled and Enabled.

Interrupt 19 Capture

Interrupt 19 is the software interrupt that handles the boot disk function. When this item is set to Immediate, the BIOS ROM of the host adaptors will immediately capture Interrupt 19 at bootup and allow the drives that are attached to these host adaptors to function as bootable disks. If this item is set to Postponed, the BIOS ROM of the host adaptors will only capture Interrupt 19 during bootup from a legacy device. The options are Immediate and Postponed.

Re-try Boot

Select Legacy Boot for the BIOS to continuously attempt to boot from the legacy boot drive. Select EFI Boot for the BIOS to continuously attempt to boot from the EFI boot drive. The options are Disabled, Legacy Boot, and EFI Boot.

Power Configuration

Watch Dog Function

If enabled, the Watch Dog timer will allow the system to automatically reboot when a non-recoverable error that lasts for more than five minutes occurs. The options are Enabled and Disabled.

Power Button Function

If this feature is set to Instant Off, the system will power off immediately as soon as the user presses the power button. If this feature is set to 4 Seconds Override, the system will power off when the user presses the power button for 4 seconds or longer. The options are Instant Off and 4 Seconds Override.

Restore on AC Power Loss

Use this item to set the power state after a power outage. Select Stay Off for the system power to remain off after a power outage. Select Power On to turn on the system power after a power outage. Select Last State to allow the system to resume its last power state before a power outage. The options are Power On, Stay Off, and Last State.

▶CPU Configuration

This screen displays CPU information as detected by the BIOS. It also allows the user to configure CPU settings.

CPU information: Processor Socket, Processor ID, Processor Frequency, Processor Maximum Ratio, Processor Minimum Ratio, Microcode Revision, L1 Cache RAM, L2 Cache RAM, L3 Cache RAM, Processor 1 Version, and Processor 2 Version.

Clock Spread Spectrum

Select Enable to allow the BIOS to monitor and attempt to reduce the level of Electromagnetic Interference caused by the components whenever needed. The options are Disable and Enable.

Hyper-Threading [All]

Select Enable to support Intel's Hyper-threading Technology to enhance CPU performance. The options are Enable and Disable.

Cores Enabled

Select the number of cores to enable. To enable all, enter 0 (zero). Maximum is twelve cores.

Execute-Disable Bit (Available if supported by the OS & the CPU)

Select Enable to support Intel® Execute Disable Bit Technology, which will allow the processor to designate areas in the system memory where an application code can be executed and where it cannot, thus preventing a worm or a virus from flooding illegal codes to overwhelm the processor or damage the system during an attack. This feature is used in conjunction with the items: "Clear MCA," "VMX," "Enable SMX," and "Lock Chipset" for Virtualization media support. The default setting is Enable. (Refer to Intel and Microsoft websites for more information.)

PPIN Control

When the Protected Processor Inventory Number (PPIN) is enabled, the processor will return a 64-bit ID number by way of the PPIN MSR. The options are Disable and Enable.

Hardware Prefetch (Available when supported by the CPU)

If this item is set to Enable, the hardware will prefetch streams of data and instructions from the main memory to the L2 cache to improve CPU performance. The options are Disable and Enable.

Adjacent Cache Prefetch (Available when supported by the CPU)

Select Enable for the CPU to prefetch both cache lines for 128 bytes as comprised. Select Disable for the CPU to prefetch both cache lines for 64 bytes. The options are Disable and Enable.

Note: Please reboot the system for changes on this setting to take effect. Please refer to Intel's web site for detailed information.

DCU (Data Cache Unit) Streamer Prefetcher (Available when supported by the CPU)

If this item is set to Enable, the DCU Streamer Prefetcher will prefetch data streams from the cache memory to the DCU (Data Cache Unit) to speed up data accessing and processing for CPU performance enhancement. The options are Disable and Enable.

DCU IP Prefetcher

If this feature is set to Enable, the IP prefetcher in the DCU (Data Cache Unit) will prefetch IP addresses to improve network connectivity and system performance. The options are Enable and Disable.

Direct Cache Access (DCA)

Select Enable to use Intel DCA (Direct Cache Access) Technology to improve the efficiency of data transferring and accessing. The options are Enable and Disable.

X2APIC

This setting allows you to enable or disable the Extended xAPIC mode that supports more than 256 interrupts over the local APIC.

AES-NI (New Encryption Standard-New Instructions)

Select Enable to use the Intel Advanced Encryption Standard (AES) New Instructions (NI) to ensure data security. The options are Enable and Disable.

Intel Virtualization Technology

When enabled, a VMM can utilize the additional hardware capabilities provided by Vanderpool Technology.

▶ Advanced Power Management Configuration

Power Technology

This setting allows you to customize power management. The options are Disabled, Energy Efficient, and Custom. Select Energy Efficient to support power-saving mode, which might have an impact on system performance. Select Custom to customize system power settings. Select Disabled to disable power-saving settings.

If the option is set to Custom, the following items will display:

▶ CPU P State Control

EIST (P-states)

EIST (Enhanced Intel SpeedStep Technology) allows the system to automatically adjust processor voltage and core frequency to reduce power consumption and heat dissipation. The options are Disable and Enable.

Turbo Mode

Select Enabled to use the Turbo Mode to boost system performance. The options are Enable and Disable.

P-state Coordination

This feature is used to change the P-state (Power-Performance State) coordination type. P-state is also known as "SpeedStep" for Intel processors. Select HW_ALL to change the P-state coordination type for hardware components only. Select SW_ALL to change the P-state coordination type for all software installed in the system. Select SW_ANY to change the P-state coordination type for a software program in the system. The options are HW_All, SW_ALL, and SW_ANY.

▶ CPU C State Control (Available when Power Technology is set to Custom)

Package C State limit

Use this item to set the limit on the C-State package register. The options are C0/1 state, C2 state, C6 (non-Retention) state, and C6 (Retention) state.

CPU C3 Report

Select Enable to allow the BIOS to report the CPU C3 State (ACPI C2) to the operating system. During the CPU C3 State, the CPU clock generator is turned off. The options are Enable and Disable.

CPU C6 Report (Available when Power Technology is set to Custom)

Select Enable to allow the BIOS to report the CPU C6 state (ACPI C3) to the operating system. During the CPU C6 state, power to all cache is turned off. The options are Enable and Disable.

Enhanced Halt State (C1E)

Select Enabled to use the "Enhanced Halt State" feature, which will significantly reduce CPU power consumption by reducing the CPU's clock cycle and voltage during a "Halt State." The options are Disable and Enable.

▶ CPU T State Control

ACPI (Advanced Configuration Power Interface) T-States

Select Enable to support CPU throttling provided by the operating system to reduce power consumption. The options are Enable and Disable.

▶Chipset Configuration

Caution: Setting wrong values may cause the system to malfunction.

▶ North Bridge

This section configures the North Bridge settings.

▶IIO Configuration

(Integrated IO)

EV DFX (Device Function On-Hide) Features

When this feature is set to Enable, the EV_DFX Lock Bits that are located on a processor will always remain clear during electric tuning. The options are Disable and Enable.

▶IIO1 Configuration

IOU2 (IIO1 PCIe Port 1)

The options are: x4x4 sets Function 1/0 visible, x8 sets function 1 visible, or Auto.

Select the target link speed. The options are: Gen 1--2.5GT/s, Gen 2--5GT/s, or Gen 3--8GT/s.

IOU0 (IIO1 PCIe Port 2)

Sets the functions that are visible.

Select the target link speed. The options are 2.5, 5, or 8GT/s.

IOU1 (IIO1 PCIe Port 3)

Sets the functions that are visible.

Select the target link speed. The options are 2.5, 5, or 8GT/s.

▶IIO2 Configuration

IOU2 (IIO2 PCIe Port 1)

The options are: x4x4 sets Function 1/0 visible, x8 sets function 1 visible, or Auto.

IOU0 (IIO2 PCIe Port 2)

Sets the functions that are visible.

Select the target link speed. The options are 2.5, 5, or 8GT/s.

IOU1 (IIO2 PCIe Port 3)

Sets the functions that are visible.

Select the target link speed. The options are 2.5, 5, or 8GT/s.

▶ IOAT Configuration

Enable IOAT

Enables or disables Intel I/O Acceleration Technology.

No Snoop

Snooping ensures cache coherency in each DMA engine. Choices are Enable or Disable.

Relaxed Ordering

Enables or disables relaxed ordering for each transaction to main memory in each DMA engine.

▶Intel VT for Directed I/O (VT-d)

Intel VT for Directed I/O

Enable or Disable Intel Virtualization Technology for Directed I/O. This reports the I/O device assignment to VMM through DMAR ACPI tables.

Interrupt Remapping

Interrupt remapping allows VMM to route device interrupts to the VM that controls the device.

▶QPI Configuration ▶QPI General Configuration

(Quick Path Interconnect)

QPI Status

This screen displays the Number of CPUs, Number of IIO, LInk Speed, Current QPI Link Frequency, QPI Global MMIO Low Base/Limit, QPI Global MMIO High Base/Limit, and QPI PCI-E Configuration Base/Siz (Size).

Use this feature to select the desired frequency for QPI Link connections. The options are 6.4GB/s, 8.0GB/s, 9.6GB/s, Auto, and Auto Limited.

Select Enable for Link L0p support. The options are Enable and Disable.

Select Enable for Link L1 support. The options are Enable and Disable.

COD Enable

This setting allows you to cluster on Die mode, which targets NUMA workloads where sharing across Caching Agents is less important than latency. The options are Enable and Disable.

Early Snoop

Early Snoop mode is best for workloads with high cache to cache transfers or for workloads that are not fully NUMA optimized. It requires memory population on all channels. The options are Enable, Disable, and Auto.

Isoc Mode

Isochronous mode can reduce or increase the credits available for memory traffic. Workstation and HEDT require Isoc enabled for caution and media performance. The options are Enable and Disable.

▶ Memory Configuration

This section displays the following Integrated Memory Controller (IMC) information.

Enforce POR

Enforces POR restrictions for DDR4 frequency and voltage programming. The options are Enable and Disable.

Memory Frequency

Allows you to set the maximum memory frequency below the enforced POR. The options are frequencies from 1333 to 2400 or Auto.

Data Scrambling

Data scrambling improves detection of DDR address line errors and reduces the probability of occurrence. The options are Disabled, Enabled and Auto.

DRAM RAPL Baseline

You can control the DRAM power by limiting memory bandwidth. The options are DRAM RAPL Mode 0, DRAM RAPL Mode 1, and Disable.

Set Throttling Mode

You can utilize the thermal sensors on the DIMMs to derive DRAM temperature estimation for throttling. The options are CLTT and Disable.

Socket Interleave Below 4GB

When enabled, this setting splits the 1-4GB address space between two sockets so that both get a chunk of local memory below 4GB. The options are Enable and Disable.

A7 Mode

A7 (Addressing) mode is recommended for most platform topologies as it is expected to yield slightly higher memory bandwidth. The options are Enable and Disable.

DIMM Information

Select this screen to view specification for your DIMMs

▶ Memory RAS Configuration

Memory RAS Configuration Setup

RAS Mode

Select the mode for memory initialization. For Mirror, writes are sent to both channels for redundancy. For Lockstep, adjacent channels must be populated identically. Or this function may be Disabled.

Memory Rank Sparing

Memory rank sparing enhances system performance. The options are Disable and Enable.

Patrol Scrub

This feature proactively searches the system memory repairing correctable errors. The options are Disable and Enable.

Patrol Scrub Interval

Select the number of hours (1-24) required to complete a full scrub. A value of zero designate Auto.

Demand Scrub

Demand Scrubbing allows the CPU to correct memory errors found on a memory module. When the CPU or I/O issues a demand-read command, and the read data from memory turns out to be a correctable error, the error is corrected and sent to the requestor (the original source). Memory is updated as well. Select Enable to use Demand Scrubbing for ECC memory correction. The options are Enable and Disable.

Device Tagging

Select Enable to support device tagging of a memory device that generates stuck-bit or hard errors The options are Disable and Enable.

▶ South Bridge

This section configures the South Bridge settings. The initial screen displays USB information including the USB Module version and the USB devices.

Legacy USB Support

Available when USB Function is not Disabled. Select Enabled to support legacy USB devices. Select Auto to disable legacy support if USB devices are not present. Select Disabled to have USB devices available for EFI (Extensive Firmware Interface) applications only. The settings are Disabled, Enabled and Auto.

XHCI Hand-Off

This feature is a work-around solution for operating systems that do not support XHCI (Extensible Host Controller Interface) hand-off. The XHCI ownership change should be claimed by the XHCI driver. The settings are Enabled and Disabled.

EHCI Hand-Off

This item is for operating systems that do not support Enhanced Host Controller Interface (EHCI) hand-off. When this item is enabled, EHCI ownership change will be claimed by the EHCI driver. The settings are Enabled and Disabled.

Port 60/64 Emulation

This feature allows I/O port 60h/64h emulation. It should be Enabled for operating systems that are not USB aware to provide a complete USB keyboard support. The settings are Enabled and Disabled.

USB 3.0 Support

For USB 3.0 support. The options are:

• Disabled: Force to EHCI mode only
• Auto: Recommended when XHCI Pre-Boot Driver is set to Disabled
- Enabled or Smart Auto: Recommended when XHCI Pre-Boot Driver is set to Enabled.

EHCI1

Controls the USB 2.0 EHCI functions. On EHCI controller must be Enabled.

EHCI2

Controls the USB 2.0 EHCI functions. On EHCI controller must be Enabled.

XHCI Pre-Boot Driver

Enable this feature to load the Intel XHCI pre-boot driver. The settings are Enabled and Disabled.

▶SATA Configuration

When this submenu is selected, the BIOS automatically detects the presence of the SATA devices that are supported by the Intel PCH chip and displays the following items:

SATA Controller

This item enables or disables the onboard SATA controller supported by the Intel PCH chip. The options are Enabled and Disabled.

Configure SATA as

Select the SATA configuration. The options are IDE, AHCI, and RAID. The items below differ depending on this choice.

If SATA is configured as IDE:

The SATA ports are listed. For each, you can identify whether the port is connected to a hard drive or a solid state drive.

If SATA is configured as AHCI, the following items are displayed:

The SATA ports are listed.

When this item is set to Enabled, the SATA AHCI controller manages the power usage of the SATA link. The controller will put the link in a low power mode during extended periods of I/O inactivity, and will return the link to an active state when I/O activity resumes. The options are Enabled and Disabled.

SATA Port 0\~ Port 5

This item displays the information detected on the installed SATA drive on the particular SATA port, including the model number of the drive, capacity, and the Software Preserve Support.

Port 0 \~ Port 5 Spin Up Device

Only devices for which this is Enabled will spin up at boot. The options are Enabled and Disabled. If no devices are Enabled, all will spin up at boot.

Port 0 \~ Port 5 SATA Device Type

For each port, you can identify whether it is connected to a hard drive or a solid state drive.

If SATA is configured as RAID, the following items are displayed:

The SATA ports are listed.

When this item is set to Enabled, the SATA AHCI controller manages the power usage of the SATA link. The controller will put the link in a low power mode during extended periods of I/O inactivity, and will return the link to an active state when I/O activity resumes. The options are Enabled and Disabled.

SATA RAID Option ROM/UEFI Driver

Select which SATA RAID firmware type to load. The options are Disabled, EFI, and Legacy.

SATA/sSATA RAID Boot Select

Select the boot capability for SATA or SATA RAID controllers. This is shared and presented in the SATA Configuration page and the sSATA Configuration page. The options are SATA Controller, sSATA Controller and Both. (Note: The Both option cannot support Windows Server 2012 r2 installation.)

SATA Port 0\~ Port 5

This item displays the information detected on the installed SATA drive on the particular SATA port, including the model number of the drive, capacity, and the Software Preserve Support.

Port 0 \~ Port 5 Spin Up Device

Only devices for which this is Enabled will spin up at boot. The options are Enabled and Disabled. If no devices are Enabled, all will spin up at boot.

Port 0 \~ Port 5 SATA Device Type

For each port, you can identify whether it is connected to a hard drive or a solid state drive.

▶ sSATA Configuration

When this submenu is selected, the BIOS automatically detects the presence of the sSATA devices that are supported by the Intel PCH chip and displays the following items:

SATA Controller

This item enables or disables the onboard SATA controller supported by the Intel PCH chip. The options are Enabled and Disabled.

Configure sSATA as

Select the sSATA configuration. The options are IDE, AHCI, and RAID. The items below differ depending on this choice.

If sSATA is configured as IDE:

The sSATA ports are listed. For each, you can identify whether the port is connected to a hard drive or a solid state drive.

If sSATA is configured as AHCI:

The sSATA ports are listed.

When this item is set to Enabled, the sSATA AHCI controller manages the power usage of the sSATA link. The controller will put the link in a low power mode during extended periods of I/O inactivity, and will return the link to an active state when I/O activity resumes. The options are Enabled and Disabled.

sSATA Port 0\~ Port 5

This item displays the information detected on the installed SATA drive on the particular SATA port, including the model number of the drive, capacity, and the Software Preserve Support.

Port 0 \~ Port 5 Spin Up Device

Only devices for which this is Enabled will spin up at boot. The options are Enabled and Disabled. If no devices are Enabled, all will spin up at boot.

Port 0 \~ Port 5 SATA Device Type

For each port, you can identify whether it is connected to a hard drive or a solid state drive.

If sSATA is configured as RAID:

The sSATA ports are listed.

When this item is set to Enabled, the sSATA AHCI controller manages the power usage of the sSATA link. The controller will put the link in a low power mode during extended periods of I/O inactivity, and will return the link to an active state when I/O activity resumes. The options are Enabled and Disabled.

sSATA RAID Option ROM/UEFI Driver

Select which SATA RAID firmware type to load. The options are Disabled, EFI, and Legacy.

SATA/sSATA RAID Boot Select

Select the boot capability for SATA or SATA RAID controllers. This is shared and presented in the SATA Configuration page and the sSATA Configuration page. The options are SATA Controller, sSATA Controller and Both. (Note: The Both option cannot support Windows Server 2012 r2 installation.)

sSATA Port 0\~ Port 3

This item displays the information detected on the installed SATA drive on the particular SATA port, including the model number of the drive, capacity, and the Software Preserve Support.

sSATA Port 0 \~ Port 3 Spin Up Device

Only devices for which this is Enabled will spin up at boot. The options are Enabled and Disabled. If no devices are Enabled, all will spin up at boot.

Port 0 \~ Port 3 sSATA Device Type

For each port, you can identify whether it is connected to a hard drive or a solid state drive.

▶Server ME Configuration

This screen displays the Management Engine configuration information, including Operational Firmware Version, Recovery Firmware Version, ME Firmware Features, ME Firmware Status #1, ME Firmware Status #2, Current State, Error Code.

No settings are configurable.

▶PCIe/PCI/PnP Configuration

PCI PERR/SERR Support

Choose whether to allow a PCI/PCI-E device to generate a PCI/PCI-E Parity-Error (PERR) number or a System-Error (SERR) number for a PCI Bus Signal Error Event. The options are Enabled and Disabled.

Above 4G Decoding (Available if the system supports 64-bit PCI decoding)

Choose to allow decoding a PCI device that supports 64-bit in the space above 4G Address. The options are Enabled and Disabled.

SR-IOV Support

If the system has PCI-E devices that supports Single Root IO Virtualization (SR-IOV), choose to Enable or Disable it.

Maximum Payload

Select Auto to allow the system BIOS to automatically set the maximum payload value for a PCI-E device to enhance system performance. The options are Auto, 128 Bytes, 256 Bytes.

Maximum Read Request

Select Auto to allow the system BIOS to automatically set the maximum Read Request size for a PCI-E device to enhance system performance. The options are Auto, 128 Bytes, 256 Bytes, 512 Bytes, 1024 Bytes, 2048 Bytes, and 4096 Bytes.

ASPM Support

This feature allows the user to set the Active State Power Management (ASPM) level for a PCI-E device. Select Auto to allow the system BIOS to automatically set the ASPM level for the system. Select Disabled to disable ASPM support. The options are Disabled and Auto.

Warning: Enabling ASPM support may cause some PCI-E devices to fail!

MMIOHBase

Set the MMIO base address above 4G decoding. The options are 56T(Bytes), 48T, 24T, 512G, or 256G.

MMIO High Size

Set the MMIO size above 4G decoding. The options are 256G(Bytes), 128G, 512G, 1024G.

AOC-UR-i4XT SLOT3 PCI-E X8 OPROM

RSC-R1UW-2E16 SLOT(1-2) PCI-E X16 OPROM

RSC-R1UW-E8 SLOT1 PCI-E X8 OPROM

For PCI add-on cards and riser cards, select the type of firmware to load for add-on cards in this slot. The options are EFI, Legacy, and Disabled.

Onboard LAN Option ROM Type

Select which type of firmware to load for onboard LANs Option ROM for system boot. The options are EFI and Legacy.

Onboard LAN1 Option ROM

Select which firmware function to load for the onboard LAN1. Choose iSCSI to use the iSCSI Option ROM to boot the computer using an iSCSI network device. Select PXE (Preboot Execution Environment) to use a PXE Option ROM to boot the computer using a PXE network device. The options for Onboard LAN 1 are PXE, iSCSI, FCoE, and Disabled.

Onboard LAN(2-4) Option ROM

(Available only if you choose PXE or Disable for LAN1) Choose whether to allow PXE firmware for LAN2, LAN3, and LAN4. Options are PXE and Disable.

Onboard Video Option ROM

This feature controls how the system executes UEFI (Unified Extensible Firmware Interface), and legacy Option ROM. Select Legacy only to boot the system using a legacy video device. The options are Disabled, Legacy, and EFI.

VGA Priority

This feature allows the user to select the graphics adapter to be used as the primary boot device. The options are Onboard, and Offboard.

Network Stack

When this feature is set to Enabled, both PXE (Preboot Execution Environment) and UEFI (Unified Extensible Firmware Interface) will be enabled for network stack support. The options are Enabled and Disabled.

▶Super IO Configuration

Super IO Chip

This item displays the Super IO chip used in the motherboard.

▶ Serial Port 1 (or 2) Configuration

Serial Port

Select Enabled to enable a serial port specified by the user. The options are Enabled and Disabled.

Change Port Settings

This option specifies the base I/O port address and the Interrupt Request address of Serial Port 1 (COM). Select Disabled to prevent the serial port from accessing any system resources. When this option is set to Disabled, the serial port becomes unavailable. The options are Auto, IO=3F8h; IRQ=4; IO=3F8h; IRQ=3, 4, 5, 6, 7, 10, 11, 12; IO=2F8h; IRQ=3, 4, 5, 6, 7, 10, 11, 12; IO=3E8h; IRQ=3, 4, 5, 6, 7, 10, 11, 12; IO=2E8h; IRQ=IRQ=3, 4, 5, 6, 7, 10, 11, 12.

▶Serial Port Console Redirection

Configure settings for serial ports.

COM 1 Console Redirection

Allows you to Enable or Disable console redirection. If you Enable, you can configure the Console Redirection Settings menu.

SOL/COM2 Console Redirection

Allows you to Enable or Disable console redirection. If you Enable, you can configure the Console Redirection Settings menu.

▶Console Redirection Settings

This feature allows the user to specify how the host computer will exchange data with the client computer, which is the remote computer used by the user.

Terminal Type

This feature allows the user to select the target terminal emulation type for Console Redirection. Select VT100 to use the ASCII Character set. Select VT100+ to add color and function key support. Select ANSI to use the Extended ASCII Character Set. Select VT-UTF8 to use UTF8 encoding to map Unicode characters into one or more bytes. The options are ANSI, VT100, VT100+, and VT-UTF8.

Bits Per second

Use this feature to set the transmission speed for a serial port used in Console Redirection. Make sure that the same speed is used in the host computer and the client computer. A lower transmission speed may be required for long and busy lines. The options are 9600, 19200, 38400, 57600 and 115200 (bits per second).

Data Bits

Use this feature to set the data transmission size for Console Redirection. The options are 7 Bits and 8 Bits.

Parity

A parity bit can be sent along with regular data bits to detect data transmission errors. Select Even if the parity bit is set to 0, and the number of 1's in data bits is even. Select Odd if the parity bit is set to 0, and the number of 1's in data bits is odd. Select None if you do not want to send a parity bit with your data bits in transmission. Select Mark to add a mark as a parity bit to be sent along with

the data bits. Select Space to add a Space as a parity bit to be sent with your data bits. The options are None, Even, Odd, Mark and Space.

Stop Bits

A stop bit indicates the end of a serial data packet. Select 1 Stop Bit for standard serial data communication. Select 2 Stop Bits if slower devices are used. The options are 1 and 2.

Flow Control

This feature allows the user to set the flow control for Console Redirection to prevent data loss caused by buffer overflow. Send a "Stop" signal to stop sending data when the receiving buffer is full. Send a "Start" signal to start sending data when the receiving buffer is empty. The options are None and Hardware RTS/CTS.

VT-UTF8 Combo Key Support

Select Enabled to enable VT-UTF8 Combination Key support for ANSI/VT100 terminals. The options are Enabled and Disabled.

Recorder Mode

Select Enabled to capture the data displayed on a terminal and send it as text messages to a remote server. The options are Disabled and Enabled.

Resolution 100x31

Select Enabled for extended-terminal resolution support. The options are Disabled and Enabled.

Legacy OS Redirection Resolution

Use this feature to select the number of rows and columns used in Console Redirection for legacy OS support. The options are 80x24 and 80x25.

Putty KeyPad

This feature selects Function Keys and KeyPad settings for Putty, which is a terminal emulator designed for the Windows OS. The options are VT100, LINUX, XTERMR6, SCO, ESCN, and VT400.

Redirection After BIOS Post

Use this feature to enable or disable legacy console redirection after BIOS POST. When set to Bootloader, legacy console redirection is disabled before booting the OS. When set to Always Enable, legacy console redirection remains enabled when booting the OS. The options are Always Enable and Bootloader.

▶Legacy Console Redirection Settings

Legacy Console Redirection Port

Choose a COM port to display redirection of legacy OS and legacy OPROM messages. The options are COM1 or SOL/COM2.

Serial Port for Out-of-Band Management/Windows Emergency Management Services (EMS)

EMS Console Redirection

Select Enabled to use a COM Port selected by the user for Console Redirection. The options are Enabled and Disabled.

▶ Console Redirection Settings (for EMS)

The submenu allows the user to configure Console Redirection settings to support Out-of-Band Serial Port management. The settings specify how the host computer will exchange data with the remote computer (used by the user). Both computers should have the same or compatible settings.

Out-of-Band Management Port

The setting selects a serial port used by the Microsoft Windows Emergency Management Services (EMS) to communicate with a remote server. The options are COM1 Console Redirection and COM2/SOL Console Redirection.

Terminal Type

This setting allows the user to select the target terminal emulation type for Console Redirection. Select VT100 to use the ASCII character set. Select VT100+ to add color and function key support. Select ANSI to use the extended ASCII character set. Select VT-UTF8 to use UTF8 encoding to map Unicode characters into one or more bytes. The options are ANSI, VT100, VT100+, and VT-UTF8.

Bits Per Second

This item sets the transmission speed for a serial port used in Console Redirection. Make sure that the same speed is used in the host computer and the client computer. A lower transmission speed may be required for long and busy lines. The options are 9600, 19200, 57600, and 115200 (bits per second).

Flow Control

This item allows the user to set the flow control for Console Redirection to prevent data loss caused by buffer overflow. Send a "Stop" signal to stop sending data when the receiving buffer is full. Send a "Start" signal to start sending data when the receiving buffer is empty. The options are None, Hardware RTS/CTS, and Software Xon/Xoff.

Data Bits, Parity, Stop Bits

The setting for each of these features is displayed.

▶ ACPI Settings

Use this feature to configure Advanced Configuration and Power Interface (ACPI) power management settings for your system.

WHEA Support

This item enables Windows Hardware Error Architecture to help determine the root cause of hardware errors. The options are Enabled and Disabled.

High Precision Event Timer

This setting allows you to activate the High Precision Event Timer that produces periodic interrupts at a much higher frequency than a real-time clock does in synchronizing multimedia streams, providing smooth playback, reducing the dependency on other timestamp calculation devices, such as an x86 RDTSC Instruction embedded in the CPU. The High Precision Event Timer is used to replace the 8254 Programmable Interval Timer. The options are Enabled and Disabled.

NUMA (NON-Uniform Memory Access)

This feature enables the Non-Uniform Memory Access ACPI support. The options are Enabled and Disabled.

PCI AER Support

This setting allows the ACPI OS to natively manage PCI Advanced Error Reporting. Options are Disabled and Enabled.

7-4 Event Logs

Supermicro SuperServer 6018U-TRTP+ - 7-4 Event Logs - 1

text_image Aptio Setup Utility - Copyright (C) 2014 American Megatrends, Inc. Main Advanced Event Logs IPMI Security Boot Save & Exit Change SMBIOS Event Log Settings View SMBIOS Event Log Press to change the SMBIOS Event Log configuration. +: Select Screen T↓: Select Item Enter: Select +/-: Change Opt. F1: General Help F2: Previous Values F3: Optimized Defaults F4: Save & Exit ESC: Exit Version 2.17.1245. Copyright (C) 2014 American Megatrends, Inc.

Select the Event Logs tab to access the following submenu items.

▶Change SMBIOS Event Log Settings

Note that any changes made here do not take effect until a reboot.

Enabling/Disabling Options

SMBIOS Event Log

Change this item to enable or disable all features of the SMBIOS Event Logging during boot. The options are Enabled and Disabled.

Runtime Error Logging Support

Change this item to enable or disable runtime error logging. The options are Enabled and Disabled.

Memory Corrected Error Enabling

This item allows you to enable the runtime event for memory correctable errors. The options are Enabled and Disabled.

Memory Correction Error Threshold

Change this item to define the system's memory correction error threshold. Directly enter a numeric value between 1 and 32767. The default value is 10.

Turn off Memory Error LED

This item allows you to turn off the Memory Error alert LED. the options are "Do Nothing" (that is, leave the LED on) or "Yes, Next reset" (that is, turn off the LED upon the next reboot).

PCI-Ex Error Enable

This item allows you to enable runtime event for PCI-Express error logging. The options are Yes or No.

Erasing Settings

Erase Event Log

This option erases all SMBIOIS logged events. The options are No, "Yes, Next reset," and "Yes, Every reset."

When Log is Full

Choose an action in the event that SMBIOS Event Log is full. The options are Do Nothing and Erase Immediately.

SMBIOS Event Log Standard Settings

Log System Boot Event

Choose whether to log system boot events. The options are Disabled and Enabled.

MECI

The Multiple Event Count Increment (MECI) counter counts the number of occurrences a duplicate event must happen before the MECI counter is incremented. This is a numeric value ranging from 1 to 255. The default value is 1.

METW

The Multiple Event Time Window (METW) defines number of minutes that must pass between duplicate log events before MECI is incremented. This is in minutes, from 0 to 99. The default value is 60.

▶View SMBIOS Event Log

This item allows the user to view the event in the SMBIOS event log. Select this item and press to view the status of an event in the log. The following categories are displayed:

Date/Time/Error Code/Severity

7-5 IPMI

Supermicro SuperServer 6018U-TRTP+ - 7-5 IPMI - 1

text_image Aptio Setup Utility - Copyright (C) 2014 American Megatrends, Inc. Main Advanced Event Logs IPMI Security Boot Save & Exit BMC Firmware Revision 1.59 IPMI STATUS Working ► System Event Log ► BMC Network Configuration Press to change the SEL event log configuration. ◆: Select Screen ↑↓: Select Item Enter: Select +/-: Change Opt. F1: General Help F2: Previous Values F3: Optimized Defaults F4: Save & Exit ESC: Exit ◆: Select Screen ↑↓: Select Item Enter: Select +/-: Change Opt. F1: General Help F2: Previous Values F3: Optimized Defaults F4: Save & Exit ESC: Exit Version 2.17.1245, Copyright (C) 2014 American Megatrends, Inc.

Select the IPMI (Intelligent Platform Management Interface) tab to access information and settings. The screen displays the BMC firmware revision number and the IPMI status.

▶System Event Log

Enabling/Disabling Options

SEL Components

Select Enabled for all system event logging at bootup. The options are Enabled and Disabled.

Erasing Settings

Erase SEL

Select 'Yes, On next reset' to erase all system event logs upon next system reboot. Select 'Yes, On every reset' to erase all system event logs upon each system reboot. Select No to keep all system event logs after each system reboot. The options are No, "Yes, On next reset," and "Yes, On every reset."

When SEL is Full

This feature allows the user to decide what the BIOS should do when the system event log is full. Select "Erase Immediately" to erase all events in the log when the system event log is full. The options are Do Nothing and Erase Immediately.

▶BMC Network Configuration

IPMI LAN Selection: This item displays the available IPMI LAN modes.

IPMI Network Link Status: This item displays the IPMI Network Link status.

Update IPMI LAN Configuration

This item allows the user to set whether the BIOS should configure the IPMI settings at next system boot. The options are No and Yes. If the option is set to Yes, the user is allowed to configure the following IPMI settings at next system boot:

Configuration Address Source

This item allows the user to select the source of the IP address for IPMI. The options are Static and DHCP.

If the Address Source is set to DHCP, the following information is displayed and not configurable. If the Address Source is set to Static, the Station IP Address, Subnet Mask, and IP Gateway IP Address can be configured. You must gather these parameters from your network administrator and enter them manually.

Station IP Address: In dotted quad form, for example 192.168.10.253

Subnet Mask: In dotted quad form, for example 255.255.0.0

Station MAC Address: Six two digit hexadecimal pairs, for example 1a.34.5e.b8.65.37.

Gateway IP Address: In dotted quad form, for example 192.168.0.1

7-6 Security

Supermicro SuperServer 6018U-TRTP+ - 7-6 Security - 1

text_image Aptio Setup Utility - Copyright (C) 2014 American Megatrends, Inc. Main Advanced Event Logs IPMI Security Boot Save & Exit Password Description If ONLY the Administrator's password is set, then this only limits access to Setup and is only asked for when entering Setup. If ONLY the User's password is set, then this is a power on password and must be entered to boot or enter Setup. In Setup the User will have Administrator rights. The password length must be In the following range: Minimum length 3 Maximum length 20 Password Check [Setup] Administrator Password Setup: Check password while invoking setup. Always: Check password while Invoking setup as well as on each boot. ++: Select Screen ↑↓: Select Item Enter: Select +/-: Change Opt. F1: General Help F2: Previous Values F3: Optimized Defaults F4: Save & Exit ESC: Exit Version 2.17.12-15. Copyright (C) 2014 American Megatrends, Inc.

This menu allows the user to configure the following security settings for the system.

Password Check

This item allows you to decide when the system should check for a password. The options are Setup and Always.

Select Setup for the system to prompt for a password before the user enters the BIOS Setup utility. Select Always for the system to prompt for a password upon each system boot and before the user enters the Setup utility.

Administrator Password

Use this feature to set the Administrator Password which is required to enter the BIOS setup utility. The length of the password should be from 3 characters to 20 characters long.

7-7 Boot

Supermicro SuperServer 6018U-TRTP+ - 7-7 Boot - 1

text_image Aptio Setup Utility - Copyright (C) 2014 American Megatrends, Inc. Main Advanced Event Logs IPMI Security Boot Save & Exit Boot Configuration Setup Prompt Timeout 1 Boot Mode Select [DUAL] FIXED BOOT ORDER Priorities Dual Boot Order #1 [Hard Disk] Dual Boot Order #2 [CD/DVD] Dual Boot Order #3 [USB Hard Disk] Dual Boot Order #4 [USB CD/DVD] Dual Boot Order #5 [USB Key] Dual Boot Order #6 [USB Floppy] Dual Boot Order #7 [Network: IBA KE SI...] Dual Boot Order #8 [UEFI Hard Disk] Dual Boot Order #9 [UEFI CO/DVD] Dual Boot Order #10 [UEFI USB Hard Disk] Dual Boot Order #11 [UEFI USB CD/DVD] Dual Boot Order #12 [UEFI USB Key] Dual Boot Order #13 [UEFI USB Floppy] Dual Boot Order #14 [UEFI Network] Dual Boot Order #15 [UEFI AP:UEFI: Bui...] ► Delete Boot Option ► NETWORK Drive BBS Priorities Number of seconds to wait for setup activation key. 65S35(0xFFFF) means Indefinite waiting. +: Select Screen ↑↓: Select Item Enter: Select +/-: Change Opt. F1: General Help F2: Previous Values F3: Optimized Defaults F4: Save & Exit ESC: Exit Version 2.17.1245, Copyright (C) 2014 American Megatrends, Inc.

This submenu allows the user to configure the following boot settings for the system.

Setup Prompt Timeout

Set the number of seconds to wait for the setup activation key. Enter 65535 (0xFFFF) to wait indefinitely.

Boot Mode Select

Select which boot device type to list below. The options are Legacy, UEFI, and Dual.

Fixed Boot Order Priorities

This option prioritizes the order of devices from which the system will boot. Select each entry in the list to choose a boot device.

  • For Dual, devices are listed in boot order #1 through #15.
  • For Legacy, devices are listed in boot order #1 through #7.
    • For UEFI, devices are listed in boot order #1 through #8.

▶ Delete Boot Option

Use this item to select a boot device to delete from the boot priority list.

Delete Boot Option

Select a boot device to delete.

▶ Network Drive BBS Priorities (Available when a device is installed in this drive)

This submenu sets the boot priority sequence from available network drives.

▶UEFI Application Boot Priorities

This submenu sets the boot priority sequence from available UEFI applications. (Not available when Legacy is selected.)

7-8 Save & Exit

Aptio Setup Utility - Copyright (C) 2014 American Megatrends, Inc. Main Advanced Event Logs IPMI Security Boot Save & Exit
Discard Changes and Exit Save Changes and Reset Save Options Save Changes Discard Changes Restore Optimized Defaults Save as User Defaults Restore User Defaults Boot Override UEFI: Built-in EFI Shell UEFI: Built-in EFI Shell UEFI: Built-In EFI Shell IBA XE Slot 0100 v2304Exit system setup without saving any changes.
+: Select Screen ↑↓: Select Item Enter: Select +/-: Change Opt. F1: General Help F2: Previous Values F3: Optimized Defaults F4: Save & Exit ESC: Exit
Version 2.17.1245, Copyright (C) 2014 American Megatrends, Inc.

Use this page to configure the Save & Exit settings for setup.

Discard Changes and Exit

Select this option to quit the BIOS setup without making any changes to the system configuration. Select Discard Changes and Exit, and press . When the dialog box appears, asking you if you want to exit the BIOS setup without saving, select Yes to quit BIOS without saving the changes.

Save Changes and Reset

When completing the system configuration changes, select this option to save the changes and reboot the computer so that the new system configuration settings can take effect.

Save Options

Save Changes

Select this option and press to save all changes you've done so far and return to the AMI BIOS utility Program. When the dialog box appears, asking you if you want to save configuration, select Yes to save the changes, or select No to return to the BIOS without making changes.

Discard Changes

Select this option and press to discard all the changes and return to the BIOS setup. When the dialog box appears, asking you if you want to load previous values, select Yes to keep the previous values, or select No to keep the changes you've made so far.

Restore Optimized Defaults

Select this option to load the optimized default settings. When the dialog box appears, asking you if you want to load optimized defaults, select Yes to load the optimized default settings, or select No to keep the defaults previously saved as the user defaults.

Save as User Defaults

Select this option to save the current settings as the user's defaults. When the dialog box appears, asking you if you want to save values as user's defaults, select Yes to save the current values as user's default settings, or select No to keep the defaults previously saved as the user's defaults.

Select this option to load the user's defaults previously saved in the system. When the dialog box appears, asking you if you want to restore user's defaults, select Yes to restore the user's defaults previously saved in the system, or select No to keep the changes you've made so far.

Boot Override

This option allows you to override the Boot Option Priorities setting in the Boot menu, and instead immediately boot the system with one of the listed devices. This is a one-time override. Select and confirm.

Appendix A

BIOS Error Beep Codes

A.1 BIOS Error Beep (POST) Codes

During the POST (Power-On Self-Test) routines, which are performed each time the system is powered on, errors may occur.

Non-fatal errors are those which, in most cases, allow the system to continue the boot-up process. The error messages normally appear on the screen.

Fatal errors are those which will not allow the system to continue the boot-up procedure. If a fatal error occurs, you should consult with your system manufacturer for possible repairs.

These fatal errors are usually communicated through a series of audible beeps. The table below lists some common errors and their corresponding beep codes encountered by users.

BIOS Error Beep (POST) Codes
Beep Code ErrorMessage Description
1 short Refresh Circuits have been reset (Ready to power up)
5 short, 1 long Memory error No memory detected in system
5 long, 2 shortDisplay memory read/write errorVideo adapter missing or with faulty memory
1 long continuous System OH System overheat condition

A.2 Additional BIOS POST Codes

The AMI BIOS supplies additional checkpoint codes, which are documented online at http://www.supermicro.com/support/manuals/ ("AMI BIOS POST Codes User's Guide").

When BIOS performs the Power On Self Test, it writes checkpoint codes to I/O port 0080h. If the computer cannot complete the boot process, a diagnostic card can be attached to the computer to read I/O port 0080h (Supermicro p/n AOC-LPC80-20).

For information on AMI updates, please refer to http://www.ami.com/products/.

Notes

Appendix B

UEFI BIOS Recovery Instructions

Warning: Do not upgrade the BIOS unless your system has a BIOS-related issue. Flashing the wrong BIOS can cause irreparable damage to the system. In no event shall Supermicro be liable for direct, indirect, special, incidental, or consequential damages arising from a BIOS update. If you need to update the BIOS, do not shut down or reset the system while the BIOS is updating to avoid possible boot failure.

B-1 An Overview to the UEFI BIOS

The Unified Extensible Firmware Interface (UEFI) provides a software-based interface between the operating system and the platform firmware in the pre-boot environment. The UEFI specification supports an architecture-independent mechanism for add-on card initialization to allow the UEFI OS loader, which is stored in the add-on card, to boot the system. The UEFI offers a clean, hands-off control to a computer system at bootup.

B-2 How to Recover the UEFI BIOS Image (-the Main BIOS Block)

A UEFI BIOS flash chip consists of a recovery BIOS block and a main BIOS block (a main BIOS image). The boot block contains critical BIOS codes, including memory detection and recovery codes for the user to flash a new BIOS image if the original main BIOS image is corrupted. When the system power is on, the boot block codes execute first. Once it is completed, the main BIOS code will continue with system initialization and bootup.

Note: Follow the BIOS recovery instructions below for BIOS recovery when the main BIOS boot crashes. However, when the BIOS boot block crashes, you will need to follow the procedures below for BIOS recovery.

B-3 To Recover the Main BIOS Block Using a USB-Attached Device

This feature allows the user to recover a BIOS image using a USB-attached device without additional utilities used. A USB flash device such as a USB Flash Drive, or a USB CD/DVD ROM/RW device can be used for this purpose. However, a USB Hard Disk drive cannot be used for BIOS recovery at this time.

The file system supported by UEFI is FAT (including FAT12, FAT16, and FAT32) installed on a bootable or non-bootable USB-attached device. However, the BIOS might need several minutes to locate the SUPER.ROM file if the media size becomes too large because it contains too many folders and files.

To perform UEFI BIOS recovery using a USB-attached device, follow the instructions below.

  1. Using a different machine, copy the "Super.ROM" binary image file into the disc Root "\" Directory of a USB device or a writeable CD/DVD.
    Note: If you cannot locate the "Super.ROM" file in your driver disk, visit our website at www.supermicro.com to download the BIOS image into a USB flash device and rename it "Super.ROM" for BIOS recovery use.
  2. Insert the USB device that contains the new BIOS image ("Super.ROM") into your USB drive and power on the system
  3. While powering on the system, please keep pressing and simultaneously on your keyboard until the following screen (or a screen similar to the one below) displays.

Caution: Please stop pressing the and keys immediately when you see the screen (or a similar screen) below; otherwise, it will trigger a system reboot.

Supermicro SuperServer 6018U-TRTP+ - B-3 To Recover the Main BIOS Block Using a USB-Attached Device - 1

text_image SAMS S S A S SPDDR DOS/OS ESPD P S S ZEN24 SHN25 ZEN36 S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S C SAMS S S S S TSSR10000000000000000000000000000000000000000000000000000000000000000000000000000 S S S F VSSR15000000000000000000000000000000000000000000000000 S S S S D VSSR155555555555555555555555555555555555555555555555555555555555555555555 SAMS STARS STARS STARS STARS STARS STARS STARS STARS STARS STARS STARS STARS STARS STARS STARS STARS STARS STARS STARS STARS STARS STARS STARS STARS STARS STARS STARS STARS STARS STARS STARS STARS STARS STARS BMC IP:18.132.161.13 FEI--System Enter Recovery Mode.. 47

Note: On the other hand, if the following screen displays, please load the "Super. ROM" file to the root folder and connect this folder to the system. (You can do so by inserting a USB device that contains the new "Super.ROM" image to your machine for BIOS recovery.)

Supermicro SuperServer 6018U-TRTP+ - B-3 To Recover the Main BIOS Block Using a USB-Attached Device - 2

text_image DMC IP: 10.132.161.13 PEI--Could Not Find Recovery Image... 87
  1. After locating the new BIOS binary image, the system will enter the BIOS Recovery menu as shown below.

Note: At this point, you may decide if you want to start with BIOS recovery. If you decide to proceed with BIOS recovery, follow the procedures below.

Supermicro SuperServer 6018U-TRTP+ - B-3 To Recover the Main BIOS Block Using a USB-Attached Device - 3

text_image Aptio Setup Utility - Copyright (C) 2010 American Negatrends, Inc. Main Advanced Event Logs IPHI Boot Security Exit Recovery WARNING! BIOS Recovery mode has been detected Flash Update Parameters Reset: NYRAH [Enabled] Proceed with Flash update Select this to start flash update +: Select Screen T4: Select Item Enter: Select +/-: Change Opt. F1: General Help F2: Previous Values F3: Optimized Defaults F4: Save & Exit ESC: Exit Version 2.10.1209, Copyright (C) 2010 American Negatrends, Inc.
  1. When the screen as shown above displays, using the arrow key, select the item "Proceed with flash update" and press the key. You will see the progress of BIOS recovery as shown in the screen below.

Note: Do not interrupt the process of BIOS flashing until it is completed.

Supermicro SuperServer 6018U-TRTP+ - B-3 To Recover the Main BIOS Block Using a USB-Attached Device - 4

text_image Aptio Setup Utility - Copyright (C) 2010 American Megatrends, Inc. Recovery WARNING! System firmware is being updated. Keyboard is locked. DO NOT TURN THE POWER OFF !!! Once firmware update is completed press any key to reboot the system Flash update progress 15 % ++: Select Screen T4: Select Item Enter: Select +/-: Change Opt. F1: General Help F2: Previous Values F3: Optimized Defaults F4: Save & Exit ESC: Exit Version 2.10.1208. Copyright (C) 2010 American Megatrends, Inc.
  1. After the process of BIOS recovery is completed, press any key to reboot the system.

Supermicro SuperServer 6018U-TRTP+ - B-3 To Recover the Main BIOS Block Using a USB-Attached Device - 5

text_image Aptio Setup Utility - Copyright (C) 2010 American Megatrends, Inc. Recovery WARNING! System firmware is being updated. Keyboard is locked. DO NOT TURN THE POWER OFF III Once firmware update is completed press any key to reboot the system Flash update progress completed. ++: Select Screen T4: Select Item Enter: Select +/-: Change Opt. F1: General Help F2: Previous Values F3: Optimized Defaults F4: Save & Exit ESC: Exit.
  1. Using a different system, extract the BIOS package into a bootable USB flash drive.
  2. When a DOS prompt appears, enter FLASH.BAT BIOSname.### at the prompt.

Note: Do not interrupt this process until BIOS flashing is completed.

  1. After seeing the message that BIOS update is completed, unplug the AC power cable from the power supply to clear the CMOS, and then plug the AC power cable in the power supply again to power on the system.
  2. Press continuously to enter the BIOS Setup utility.
  3. Press to load default settings.
  4. After loading default settings, press to save the settings and exit the BIOS Setup utility.

Appendix C

System Specifications

Processors

Two E5-2600 v3/v4 series series processors in LGA 2011 sockets (R3)

Note: Please refer to our web site for a complete listing of supported processors.

Chipset

Intel PCH C612

BIOS

16 MB SPI AMI BIOS® SM Flash UEFI BIOS

Memory Capacity

Integrated memory controller supports DDR4 288-pin memory of up to 3 TB of Load Reduction (LRDIMM) or of up to 768 GB of Registered (RDIMM)/Non-volatile (NV-DIMM) EEC 2400/2133/1866/1600/1333 MHz modules in 24 DIMM slots.

Note: See the memory section in Chapter 5 for details.

SATA Controller

Ten SATA 3.0 ports; six ports supported by the Intel PCH and four ports supported by the Intel SCU (RAID 0, 1, 5 and 10 are supported by LSI Software RAID)

Drive Bays

The chassis supports four hot-swap 3.5"hard disk drives. The default configuration supports SATA drives. Expansion cards allow SAS3.

Expansion Slots

  • Two full-height full-length or one double width GPU
    • One low profile card
    • Another internal low profile card

Serverboard

X10DRU-i+ (proprietary form factor)

Dimensions: 19.7" x 9.2" (500.4 x 233.7 mm)

Chassis

SC819UTQ-R750 (1U rackmount)

Dimensions: (WxHxD) 17.2 x 1.7 x 29.0 in. (437 x 43 x 736 mm)

System Cooling

Four to eight sets of 4-cm counter-rotating cooling fans (fan speed controlled by IPMI)

System Input Requirements

AC Input Voltage: 100-240 VAC

Rated Input Current: 9.5-4.5 Amps

Rated Input Frequency: 50-60 Hz

Power Supply

80-plus Platinum AC-DC, (Part# PWS-750P)

Rated Output Power: 750W

Rated Output Voltages: +12V, +12Vsb (2A)

Operating Environment

Operating Temperature: 10°C to 35°C (50°F to 95°F)

Expanded Operating Temperature: 5°C to 40°C (41°F to 104°F) *1,2

Non-Operating Temperature: -40^ to 70^ ( -40^ to 158^ )

Operating Relative Humidity: 8% to 90% (non-condensing)

Non-Operating Relative Humidity: 5% to 95% (non-condensing)

\*Conditions for 35-40°C Operating Temperature

  • Change heatsinks to part SNK-P0057PSU.
    • Install eight cooling fans.
    • GPU is not supported.

Note 1: When operating in the expanded temperature range, system performance is equivalent to the normal operating temperature range.

Note 2: When operating in the expanded temperature range, select a CPU for which the TDP is between 85 W to 145 W. CPUs E5-2667 v3, E5-2643 v3, E5-2637 v3, and E5-2623 v3 are not supported.

Regulatory Compliance

Electromagnetic Emissions: FCC Class A, EN 55032 Class A, EN 61000-3-2/3-3, CISPR 32 Class A

Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11)

Other: VCCI-CISPR 32 and AS/NZS CISPR 32

Environmental: Directive 2011/65/EU and DELEGATED DIRECTIVE (EU) 2015/863 and Directive 2012/19/EU

Safety: CSA/EN/IEC/UL 60950-1 Compliant, UL or CSA Listed (USA and Canada), CE Marking (Europe)

Perchlorate Warning

California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. "Perchlorate Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate"

(continued from front)

The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nuclear facilities or systems, aircraft, aircraft devices, aircraft/emergency communication devices or other critical systems whose failure to perform be reasonably expected to result in significant injury or loss of life or catastrophic property damage. Accordingly, Supermicro disclaims any and all liability, and should buyer use or sell such products for use in such ultra-hazardous applications, it does so entirely at its own risk. Furthermore, buyer agrees to fully indemnify, defend and hold Supermicro harmless for and against any and all claims, demands, actions, litigation, and proceedings of any kind arising out of or related to such ultra-hazardous use or sale.

Notes

Table of contents Click a title to access it
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Supermicro

Model : SuperServer 6018U-TRTP+

Category : Server