BEKO

BAFBF 181 - Washing machine BEKO - Free user manual and instructions

Find the device manual for free BAFBF 181 BEKO in PDF.

📄 28 pages English EN Download 💬 AI Question
Notice BEKO BAFBF 181 - page 4
Pick your language and provide your email: we'll send you a specifically translated version.

User questions about BAFBF 181 BEKO

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Washing machine in PDF format for free! Find your manual BAFBF 181 - BEKO and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. BAFBF 181 by BEKO.

USER MANUAL BAFBF 181 BEKO

Split-type room air conditioner

User Manual

BEKO BAFBF 181 - Split-type room air conditioner - 1

natural_image Line drawing of a cylindrical air conditioner unit with lid and ventilation slots (no text or symbols)

BAFBF 120 | BAFBF 121 | BAFBF 180

BAFBF 181 | BAFBF 240 | BAFBF 241

EN

Please read this user manual first!

Dear Customer,

Thank you for preferring a Beko product. We hope that you get the best results from your product which has been manufactured with high quality and state-of-the-art technology. Therefore, please read this entire user manual and all other accompanying documents carefully before using the product and keep it as a reference for future use. If you handover the product to someone else, give the user manual as well. Follow all warnings and information in the user manual.

Meanings of the symbols

Following symbols are used in the various section of this manual:

BEKO BAFBF 181 - Meanings of the symbols - 1

Important information or useful hints about usage.

BEKO BAFBF 181 - Meanings of the symbols - 2

Warning for hazardous situations with regard to life and property.

BEKO BAFBF 181 - Meanings of the symbols - 3

Warning to actions that must never perform.

BEKO BAFBF 181 - Meanings of the symbols - 4

Warning for electric shock.

BEKO BAFBF 181 - Meanings of the symbols - 5

Warning for danger of fire.

BEKO BAFBF 181 - Meanings of the symbols - 6

Warning for hot surfaces.

CONTENTS

1 Safety instructions 4

2 Unit specifications and features 7

2.1 Unit parts 7
2.2 Achieving optimal performance 8
2.3 Inverter split type....8
2.4 Fixed-speed type 9
2.5 Other features....9

3 Manual operation (without remote) 14

3.1 How to operate your unit without the remote control 14

4 Care and maintenance 15

4.1 Cleaning your indoor unit 15
4.2 Cleaning your air filter 15
4.3 Air filter reminders (optional)....17
4.4 Maintenance - long periods of non-use.... 18
4.5 Maintenance-pre-season inspection....19

5 Troubleshooting 20

5.1 Common issues 20
5.2 Troubleshooting 22

6 Disposal guidelines 24

1 Safety instructions

Read safety precautions before installation Incorrect installation due to ignoring instructions can cause serious damage or injury.

The seriousness of potential damage or injuries is classified as Warning.

Warning

This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

Installation warnings

Ask an authorized dealer to install this air conditioner. Inappropriate installation may cause water leakage, electric shock, or fire.

All repairs, maintenance and relocation of this unit must be performed by an authorized service technician. Inappropriate repairs can lead to serious injury or product failure.

Warnings for product use

If an abnormal situation arises (like a burning smell), immediately turn off the unit and pull the power plug. Call your dealer for instructions to avoid electric shock, fire or injury.

Do not insert fingers, rods or other objects into the air inlet or outlet. This may cause injury, since the fan may be rotating at high speeds.

1 Safety instructions

Do not use flammable sprays such as hair spray, lacquer or paint near the unit. This may cause fire or combustion.

Do not operate the air conditioner in places near or around combustible gases. Emitted gas may collect around the unit and cause explosion.

Do not operate the air conditioner in a wet room (e.g., bathroom or laundry room). This can cause electrical shock and cause the product to deteriorate.

Do not expose your body directly to cool air for a prolonged period of time.

Electrical warnings

Only use the specified power cord. If the power cord is damaged, it must be replaced by the manufacturer or certified service agent.

Keep power plug clean. Remove any dust or grime that accumulates on or around the plug. Dirty plugs can cause fire or electric shock.

Do not pull power cord to unplug unit. Hold the plug firmly and pull it from the outlet. Pulling directly on the cord can damage it, which can lead to fire or electric shock.

Do not use an extension cord, manually extend the power cord, or connect other appliances to the same outlet as the air conditioner. Poor electrical connections, poor insulation, and insufficient voltage can cause fire.

Cleaning and maintenance warnings

Turn off the device and pull the plug before cleaning. Failure to do so can cause electrical shock.

1 Safety instructions

Do not clean the air conditioner with excessive amounts of water.
Do not clean the air conditioner with combustible cleaning agents.

Combustible cleaning agents can cause fire or deformation.

Warning

If the air conditioner is used together with burners or other heating devices, thoroughly ventilate the room to avoid oxygen deficiency.
Turn off the air conditioner and unplug the unit if you are not going to use it for a long time.
Turn off and unplug the unit during storms.
Make sure that water condensation can drain unhindered from the unit.
Do not operate the air conditioner with wet hands. This may cause electric shock.
Do not use device for any other purpose than its intended use.
Do not climb onto or place objects on top of the outdoor unit.
Do not allow the air conditioner to operate for long periods of time with doors or windows open or if the humidity is very high.

2 Unit specifications and features

2.1 Unit parts
BEKO BAFBF 181 - Unit specifications and features - 1

text_image 1 2 3 4 5 6 88 Fresh Defrost Run Timer Fresh Defrost Run Timer Fresh Defrost Run Timer 88
  1. Display window
  2. Power Cable (Some Units)
  3. Remote Control
  4. Remote Control Holder (Some Units)
  5. Louver
  6. Front Panel

Display Code Meanings

"Fresh" when Fresh feature is activated(some units)

"Defrost" when defrost feature is activated.

"Run" when the unit is on.

"Timer" when TIMER is set.

"88" not available for all units.

When ECO function(some units) is activated, the B dominates gradually one by one as -- -- E- C O -- set temperature -- E..... in one second interval.

In other modes, the unit will display your temperature setting.

In Fan mode, the unit will display the room temperature.

When error occurs, it displays error code.

“”for 3 seconds when:

  • TIMER ON is set
  • FRESH, SWING, TURBO, or SILENCE features are turned on
    "OF for 3 seconds when:
  • TIMER OFF is set

2 Unit specifications and features

  • FRESH, SWING, TURBO, or SILENCE features are turned off
    " when anti-cold air feature is turned on
    "86 when defrosting
    "56 when unit is self-cleaning
    " when freeze protection is turned on

BEKO BAFBF 181 - Unit specifications and features - 1

Note: A guide on using the infrared remote is not included in this literature package.

2.2 Achieving optimal performance

Optimal performance for the COOL, HEAT, and DRY modes can be achieved in the following temperature ranges. When your air conditioner is used outside of these ranges, certain safety protection features will activate and cause the unit to perform less than optimally.

2.3 Inverter split type

COOL mode HEAT mode DRY mode
Room Temperature 17°C-32°C(63°F - 90°F)0°C - 30°C(32°F - 86°F)10°C - 32°C(50°F - 90°F)
Outdoor Temperature0°C - 50°C(32°F - 122°F)-15°C - 30°C(5°F - 86°F)0°C - 50°C(32°F - 122°F)
-15°C - 50°C(5°F - 122°F)(For models with low temp. cooling systems.)
0°C - 60°C(32°F - 140°F)(For special tropical models)0°C - 60°C(32°F - 140°F)(For special tropical models)

For outdoor units with auxiliary electric heater

When outside temperature is below 0^ C ( 32^ F), we strongly recommend keeping the unit plugged in at all time to ensure smooth ongoing performance.

2 Unit specifications and features

2.4 Fixed-speed type

COOL mode HEAT mode DRY mode
Room Temperature17°-32°C(63°-90°F)0°-30°C(32°-86°F)10°-32°C(50°-90°F)
Outdoor Temperature18°-43°C(64°-109°F)-7°-24°C(19°-75°F)11°-43°C(52°-109°F)
-7°-43°C(19°-10 9°F)(For models with low-temp cooling systems)18°-43°C(64°-109°F)
18°-54°C(64°-129°F)(For special tropical models)18°-54°C(64°-129°F)(For special tropical models)

To further optimize the performance of your unit, do the following:

  • Keep doors and windows closed.
  • Limit energy usage by using TIMER ON and TIMER OFF functions.
  • Do not block air inlets or outlets.
  • Regularly inspect and clean air filters.

For a detailed explanation of each function, refer to the Remote control manual.

2.5 Other features

- Auto-restart

If the unit loses power, it will automatically restart with the prior settings once power has been restored.

- Anti-mildew (some units)

When turning off the unit from COOL, AUTO (COOL), or DRY modes, the air conditioner will continue operate at very low power to dry up condensed water and prevent mildew growth.

- Wireless control (some units)

Wireless control allows you to control your air conditioner using your mobile phone and a Wireless connection.

For the USB device access, replacement, maintenance operations must be carried out by professional staff.

2 Unit specifications and features

- Louver angle memory (some units)

When turning on your unit, the louver will automatically resume its former angle.

• Refrigerant leakage detection (some units)

The indoor unit will automatically display "EC" The "timer" indicator light turns off and the "run" indicator light flashes 7 times when the unit detects refrigerant leakage.

• Air filter reminders (some units)

Air filter cleaning reminder

After 240 hours of use, the "run" & "timer" indicator lamps on the indoor unit will flash simultaneously and the display window on the indoor unit will flash "CL" (if applicable). This is a reminder to clean your filter. After 15 seconds, the unit will revert to its previous display.

To reset the reminder, press the LED button on your remote control 4 times, or press the MANUAL CONTROL bottom 3 times. If you don't reset the reminder, the "CL", "run" & "timer" indicator lamps will flash again when you restart the unit.

Air filter replacement reminder

After 2,880 hours of use, the "run" & "timer" indicator lamps will flash simultaneously for 10 times, then remain on for five seconds, and the display window on the indoor unit will flash "nF"(if applicable). This is a reminder to replace your filter. After that, the unit will revert to its previous display.

To reset the reminder, press the LED button on your remote control 4 times, or press the MANUAL CONTROL botton 3 times. If you don't reset the reminder, the "nF", "run" & "timer" indicator lamps will flash again when you restart the unit.

For a detailed explanation of your unit's advanced functionality (such as TURBO mode and its self-cleaning functions), refer to the Remote Control Manual.

BEKO BAFBF 181 - Air filter replacement reminder - 1

Note:

Illustrations in this manual are for explanatory purposes. The actual shape of your indoor unit may be slightly different. The actual shape shall prevail.

- Setting angle of air flow

Setting vertical angle of air flow

While the unit is on, use the SWING/DIRECT button to set the direction (vertical angle) of airflow.

  1. Press the SWING/DIRECT button once to activate the louver. Each time you press the button, it will adjust the louver by 6°. Press the button until the direction you prefer is reached.
  2. To make the louver swing up and down continuously, press and hold the SWING/DIRECT button for 3 seconds. Press it again to stop the automatic function.

Setting horizontal angle of air flow

The horizontal angle of the airflow must be set manually. Grip the deflector rod (See Fig.B) and manually adjust it to your preferred direction.

2 Unit specifications and features

For some units, the horizontal angle of the airflow can be set by remote control, please refer to the Remote Control Manual.

BEKO BAFBF 181 - Unit specifications and features - 1

Note on louver angles

When using COOL or DRY mode, do not set louver at too vertical an angle for long periods of time. This can cause water to condense on the louver blade, which will drop on your floor or furnishings. (See Fig.A)

When using COOL or HEAT mode, setting the louver at too vertical an angle can reduce the performance of the unit due to restricted air flow.

Do not move louver by hand. This will cause the louver to become out of sync. If this occurs, turn off the unit and unplug it for a few seconds, then restart the unit. This will reset the louver.

BEKO BAFBF 181 - Note on louver angles - 1

text_image Range

Fig. A

BEKO BAFBF 181 - Note on louver angles - 2

Warning

Do not keep louver at too vertical an angle for long periods of time. This can cause water condensation to drip on your furnishings.

BEKO BAFBF 181 - Warning - 1

Warning

Do not put your fingers in or near the blower and suction side of the unit. The high-speed fan inside the unit may cause injury.

2 Unit specifications and features

BEKO BAFBF 181 - Unit specifications and features - 1

text_image Deflector rod

Fig. B

- Sleep operation

The SLEEP function is used to decrease energy use while you sleep (and don't need the same temperature settings to stay comfortable). This function can only be activated via remote control. Press the SLEEP button when you are ready to go to sleep. When in COOL mode, the unit will increase the temperature by 1°C (2°F) after 1 hour, and will increase an additional 1°C (2°F) after another hour. When in HEAT mode, the unit will decrease the temperature by 1°C (2°F) after 1 hour, and will decrease an additional 1°C (2°F) after another hour. It will hold the new temperature for 5 hours, then the unit will turn off automatically.

BEKO BAFBF 181 - - Sleep operation - 1

Note: The SLEEP function is not available in FAN or DRY mode.

2 Unit specifications and features

SLEEP Operation
BEKO BAFBF 181 - Unit specifications and features - 1

flowchart
graph LR
    A["Set temperature"] --> B["+/-1°C/2°F +/-1°C/2°F"]
    B --> C["1hr1h"]
    C --> D["Time interval"]
    D --> E["7 hours timer off"]
    E --> F["Saving energy during sleep"]

B Manual operation (without remote)

3.1 How to operate your unit without the remote control

In the event that your remote control fails to work, your unit can be operated manually with the MANUAL CONTROL button located on the indoor unit. Note that manual operation is not a long-term solution, and that operating the unit with your remote control is strongly recommended.

Before manual operation

Unit must be turned off before manual operation.

To operate your unit manually:

  1. Open the front panel of the indoor unit.
  2. Locate the MANUAL CONTROL button on the right-hand side of the unit.
  3. Press the MANUAL CONTROL button one time to activate FORCED AUTO mode.
  4. Press the MANUAL CONTROL button again to activate FORCED COOLING mode.
  5. Press the MANUAL CONTROL button a third time to turn the unit off.
  6. Close the front panel.

BEKO BAFBF 181 - Before manual operation - 1

Warning

The manual button is intended for testing purposes and emergency operation only. Please do not use this function unless the remote is lost and it is absolutely necessary. To restore regular operation, use the remote control to activate the unit.

BEKO BAFBF 181 - Warning - 1

text_image Manual control button AUTOCOOL

4 Care and maintenance

4.1 Cleaning your indoor unit

BEKO BAFBF 181 - Cleaning your indoor unit - 1

Before cleaning or maintenance

Always turn off your air conditioner system and disconnect its power supply before cleaning or maintenance.

BEKO BAFBF 181 - Cleaning your indoor unit - 2

Warning

Only use a soft, dry cloth to wipe the unit clean. If the unit is especially dirty, you can use a cloth soaked in warm water to wipe it clean.

  • Do not use chemicals or chemically treated cloths to clean the unit
  • Do not use benzene, paint thinner, polishing powder or other solvents to clean the unit. They can cause the plastic surface to crack or deform.
  • Do not use water hotter than 40^ (104°F) to clean the front panel. This can cause the panel to deform or become discolored.

4.2 Cleaning your air filter

A clogged air conditioner can reduce the cooling efficiency of your unit, and can also be bad for your health. Make sure to clean the filter once every two weeks.

  1. Lift the front panel of the indoor unit.
  2. First press the tab on the end of filter to loosen the buckle, lift it up, then pull it towards yourself.
  3. Now pull the filter out.
  4. If your filter has a small air freshening filter, unclip it from the larger filter. Clean this air freshening filter with a hand-held vacuum.
  5. Clean the large air filter with warm, soapy water. Be sure to use a mild detergent.
  6. Rinse the filter with fresh water, then shake off excess water.
  7. Dry it in a cool, dry place, and refrain from exposing it to direct sunlight.
  8. When dry, re-clip the air freshening filter to the larger filter, then slide it back into the indoor unit.
  9. Close the front panel of the indoor unit.

4 Care and maintenance

BEKO BAFBF 181 - Care and maintenance - 1

text_image Filter Tab

BEKO BAFBF 181 - Care and maintenance - 2

natural_image Diagram showing a hand pressing down a car air vent with a downward arrow indicating airflow direction (no text or symbols present)

BEKO BAFBF 181 - Care and maintenance - 3

text_image Remove air freshening filter from back of larger filter (some units)

BEKO BAFBF 181 - Care and maintenance - 4

natural_image Diagram showing a water tap above a grid with a shaded rectangular area and a small object below (no text or symbols)

BEKO BAFBF 181 - Care and maintenance - 5

Warning

Do not touch air freshening (Plasma) filter for at least 10 minutes after turning off the unit.

4 Care and maintenance

BEKO BAFBF 181 - Care and maintenance - 1

Warning

  • Before changing the filter or cleaning, turn off the unit and disconnect its power supply.
  • When removing filter, do not touch metal parts in the unit. The sharp metal edges can cut you.
  • Do not use water to clean the inside of the indoor unit. This can destroy insulation and cause electrical shock.
  • Do not expose filter to direct sunlight when drying. This can shrink the filter.

4.3 Air filter reminders (optional)

4.3.1 Air filter cleaning reminder

After 240 hours of use, the display window on the indoor unit will flash "CL." This is a reminder to clean your filter. After 15 seconds, the unit will revert to its previous display.

To reset the reminder, press the LED button on your remote control 4 times, or press the MANUAL CONTROL button 3 times. If you don't reset the reminder, the "CL" indicator will flash again when you restart the unit.

4.3.2 Air filter replacement reminder

After 2,880 hours of use, the display window on the indoor unit will flash "nF." This is a reminder to replace your filter. After 15 seconds, the unit will revert to its previous display.

To reset the reminder, press the LED button on your remote control 4 times, or press the MANUAL CONTROL button 3 times. If you don't reset the reminder, the "nF" indicator will flash again when you restart the unit.

BEKO BAFBF 181 - Air filter replacement reminder - 1

Warning

  • Any maintenance and cleaning of outdoor unit should be performed by an authorized dealer or licensed service provider.
  • Any unit repairs should be performed by authorized dealer or licensed service provider.

4 Care and maintenance

4.4 Maintenance - long periods of non-use

If you plan not to use your air conditioner for an extended period of time, do the following:

BEKO BAFBF 181 - Maintenance - long periods of non-use - 1

natural_image 3D grid diagram with a small arrow pointing to the top-right corner (no text or symbols)

Clean all filters

BEKO BAFBF 181 - Maintenance - long periods of non-use - 2

natural_image Simple line drawing of a house with wavy roof and roof, no text or symbols present

Turn on FAN function until unit dries out completely

BEKO BAFBF 181 - Maintenance - long periods of non-use - 3

text_image Prohibition sign with a circular symbol containing a crossed-out lightning bolt and diagonal lines, indicating no protection or resistance.

BEKO BAFBF 181 - Maintenance - long periods of non-use - 4

natural_image Technical line drawing of a device with internal components (no text or symbols)

Turn off the unit and disconnect the power Remove batteries from remote control

4 Care and maintenance

4.5 Maintenance -pre-season inspection

After long periods of non-use, or before periods of frequent use, do the following:

BEKO BAFBF 181 - Maintenance -pre-season inspection - 1

Check for leaks Replace batteries
BEKO BAFBF 181 - Maintenance -pre-season inspection - 2

text_image Two safety symbols: one with a diagonal line crossing over a building, another with a crossed-out box and a potted plant.

Make sure nothing is blocking all air inlets and outlets

5 Troubleshooting

BEKO BAFBF 181 - Troubleshooting - 1

Safety precautions

If ANY of the following conditions occurs, turn off your unit immediately!

• The power cord is damaged or abnormally warm
- You smell a burning odor
• The unit emits loud or abnormal sounds
• A power fuse blows or the circuit breaker frequently trips
• Water or other objects fall into or out of the unit

Do not attempt to fix these yourself! Contact authorized service provider immediately!

5.1 Common issues

The following problems are not a malfunction and in most situations will not require repairs.

Issue Possible Causes
Unit does not turn on when pressing ON/OFF buttonThe Unit has a 3-minute protection feature that prevents the unit from overloading. The unit cannot be restarted within three minutes of being turned off.
The unit changes from COOL/HEAT mode to FAN modeThe unit may change its setting to prevent frost from forming on the unit. Once the temperature increases, the unit will start operating in the previously selected mode again.
The set temperature has been reached, at which point the unit turns off the compressor. The unit will continue operating when the temperature fluctuates again.
The indoor unit emits white mistIn humid regions, a large temperature difference between the room's air and the conditioned air can cause white mist.
Both the indoor and outdoor units emit white mistWhen the unit restarts in HEAT mode after defrosting, white mist may be emitted due to moisture generated from the defrosting process.
The indoor unit makes noisesA rushing air sound may occur when the louver resets its position.
A squeaking sound may occur after running the unit in HEAT mode due to expansion and contraction of the unit's plastic parts.

5 Troubleshooting

Issue Possible Causes
Both the indoor unit and outdoor unit make noisesLow hissing sound during operation: This is normal and is caused by refrigerant gas flowing through both indoor and outdoor units.
Low hissing sound when the system starts, has just stopped running, or is defrosting: This noise is normal and is caused by the refrigerant gas stopping or changing direction.
Squeaking sound: Normal expansion and contraction of plastic and metal parts caused by temperature changes during operation can cause squeaking noises.
The outdoor unit makes noisesThe unit will make different sounds based on its current operating mode.
Dust is emitted from either the indoor or outdoor unitThe unit may accumulate dust during extended periods of non-use, which will be emitted when the unit is turned on. This can be mitigated by covering the unit during long periods of inactivity.
The unit emits a bad odorThe unit may absorb odors from the environment (such as furniture, cooking, cigarettes, etc.) which will be emitted during operations.
The unit's filters have become moldy and should be cleaned.
The fan of the outdoor unit does not operateDuring operation, the fan speed is controlled to optimize product operation.
Operation is erratic, unpredictable, or unit is unresponsiveInterference from cell phone towers and remote boosters may cause the unit to malfunction.In this case, try the following:Disconnect the power, then reconnect.Press ON/OFF button on remote control to restart operation.

BEKO BAFBF 181 - Troubleshooting - 1

Note:

If problem persists, contact a local dealer or your nearest customer service center. Provide them with a detailed description of the unit malfunction as well as your model number.

5 Troubleshooting

5.2 Troubleshooting

When troubles occur, please check the following points before contacting a repair company.

Problem Possible Causes Solution
Poor Cooling PerformanceTemperature setting may be higher than ambient room temperatureLower the temperature setting
The heat exchanger on the indoor or outdoor unit is dirtyClean the affected heat exchanger
The air filter is dirtyRemove the filter and clean it according to instructions
The air inlet or outlet of either unit is blockedTurn the unit off, remove the obstruction and turn it back on
Doors and windows are openMake sure that all doors and windows are closed while operating the unit
Excessive heat is generated by sunlightClose windows and curtains during periods of high heat or bright sunshine
Too many sources of heat in the room (people, computers, electronics, etc.)Reduce amount of heat sources
Low refrigerant due to leak or long-term useCheck for leaks, re-seal if necessary and top off refrigerant
SILENCE function is activated(optional function)SILENCE function can lower product performance by reducing operating frequency. Turn off SILENCE function.
The unit is not workingPower failure Wait for the power to be restored
The power is turned off Turn on the power
The fuse is burned out Replace the fuse
Remote control batteries are dead Replace batteries
The Unit's 3-minute protection has been activatedWait three minutes after restarting the unit
Timer is activated Turn timer off

5 Troubleshooting

Problem Possible Causes Solution
The unit starts and stops frequentlyThere's too much or too little refrigerant in the systemCheck for leaks and recharge the system with refrigerant.
Incompressible gas or moisture has entered the system.Evacuate and recharge the system with refrigerant
The compressor is broken Replace the compressorcompressor
The voltage is too high or too lowInstall a manostat to regulate the voltage
Poor heating performanceThe outdoor temperature is extremtly lowUse auxiliary heating device
Cold air is entering through doors and windowsMake sure that all doors and windows are closed during use
Low refrigerant due to leak or long-term useCheck for leaks, re-seal if necessary and top off refrigerant
Indicator lamps continue flashingThe unit may stop operation or continue to run safely. If the indicator lamps continue to flash or error codes appear, wait for about 10 minutes. The problem may resolve itself.If not, disconnect the power, then connect it again. Turn the unit on.If the problem persists, disconnect the power and contact your nearest customer service center.
Error code appears in the window display of indoor unit:•E0, E1, E2...•P1, P2, P3...•F1, F2, F3...

BEKO BAFBF 181 - Troubleshooting - 1

Note:

If your problem persists after performing the checks and diagnostics above, turn off your unit immediately and contact an authorized service center.

6 isposal guidelines

This appliance contains refrigerant and other potentially hazardous materials. When disposing of this appliance, the law requires special collection and treatment. Do not dispose of this product as household waste or unsorted municipal waste.

When disposing of this appliance, you have the following options:

  • Dispose of the appliance at designated municipal electronic waste collection facility.
  • When buying a new appliance, the retailer will take back the old appliance free of charge.
    • The manufacturer will take back the old appliance free of charge.
  • Sell the appliance to certified scrap metal dealers.

BEKO BAFBF 181 - isposal guidelines - 1

Special notice

Disposing of this appliance in the forest or other natural surroundings endangers your health and is bad for the environment. Hazardous substances may leak into the ground water and enter the food chain.

BEKO BAFBF 181 - Special notice - 1

natural_image Symbol of a trash bin crossed with no text or labels, representing waste sorting or disposal (no text present)

This symbol indicates that this product shall not be disposed with other household wastes at the end of its service life. Used device must be returned to official collection point for recycling of electrical and electronic devices. To find these collection systems please contact to your local authorities or retailer where the product was purchased. Each household performs important role in recovering and recycling of old appliance. Appropriate disposal of used appliance helps prevent potential negative consequences for the environment and human health.

Model NameBAFBF 120 / BAFBF 121BAFBF 180 / BAFBF 181BAFBF 240 / BAFBF 241
RefrigerantR410AR410AR410A
Total Refrigerant Amount (g)570g960g1100g
Climate ClassT1T1T1
Cooling Capacity (Btu/h) [T1]118021799822001
Cooling Capacity (W) [T1]345952756448
Heating Capacity (Btu/h)
Heating Capacity (W)
Energy Efficiency Cooling (W/W) [T1]3.163.13.1
Energy Efficiency Heating (W/W)
Energy Level1 star1 star1 star
Energy Level
Cooling Power Input (W)109517002080
Heating Power Input (W)
Voltage/Frequency (V/Hz)220-240V~50Hz, 1Ph220-240V~50Hz, 1Ph220-240V~50Hz, 1Ph
Cooling Running Current (A)4.87.49.0
Heating Running Current (A)
High Pressure Pipe Diameter (mm)Φ6.35Φ6.35Φ9.52
Low Pressuer Pipe Diameter (mm)Φ12.7Φ12.7Φ15.9
Indoor Unit (WxHxD) mm805x194x2851040x220x3271040x220x327
Outdoor Unit (WxHxD) mm770x300x555770x300x555845x363x702
Indoor Unit Net Weight (kg)8.413.113.2
Outdoor Unit Net Weight (kg)28.63445.6

BEKO BAFBF 181 - Special notice - 2

natural_image Abstract geometric design with blue triangular shapes on white background (no text or symbols)
Table of contents Click a title to access it
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : BEKO

Model : BAFBF 181

Category : Washing machine