USER MANUAL Cora FTKM20Q2VMA DAIKIN

natural_image Front view of a white air conditioner unit with cooling fins and ventilation grilles (no text or symbols)

MODELS

FTXV20W2VMA
FTXV25W2VMA
FTXV35W2VMA
FTXV46W2VMA

DAIKIN Cora FTKM20Q2VMA - MODELS - 1

natural_image Illustration of a globe with a stylized city skyline and continents, no text or symbols present.

Features

Enhanced comfort and energy savings

DAIKIN Cora FTKM20Q2VMA - Enhanced comfort and energy savings - 1

INTELLIGENT EYE

The INTELLIGENT EYE sensor detects human movement and adjusts the right and left airflow direction. If no one is in the room for more than 20 minutes, the operation automatically changes to energy saving operation. The INTELLIGENT EYE sensor works differently depending on the situation. ▶Page 15

DAIKIN Cora FTKM20Q2VMA - INTELLIGENT EYE - 1

WEEKLY TIMER

Up to 4 timer settings can be saved for each day of the week according to your family's life style. The WEEKLY TIMER allows you to set on/off times and the desired temperature. ▶Page 22

Other functions

DAIKIN Cora FTKM20Q2VMA - Other functions - 1

COMFORT AIRFLOW OUTDOOR UNIT QUIET

The airflow direction is upward while in COOL operation, and downward while in HEAT operation. This function prevents cold or warm air from blowing directly on your body. ▶Page 14

DAIKIN Cora FTKM20Q2VMA - COMFORT AIRFLOW OUTDOOR UNIT QUIET - 1

OUTDOOR UNIT QUIET operation assures a low noise level of the outdoor unit. This function is useful to maintain a quiet neighbourhood.

DAIKIN Cora FTKM20Q2VMA - COMFORT AIRFLOW OUTDOOR UNIT QUIET - 2

natural_image Modern minimalist living room interior with white sofa, wall-mounted air conditioner unit, and potted plant (no text or symbols visible)

DAIKIN Cora FTKM20Q2VMA - COMFORT AIRFLOW OUTDOOR UNIT QUIET - 3

ECONO

This function enables efficient operation by limiting the maximum power consumption. It is useful when using the air conditioner and other electrical devices simultaneously on a shared electrical circuit. ▶Page 18

Contents

Read Before Operation

Safety Precautions 3

Names of Parts 5

Preparation Before Operation 9

Basic Operation

DAIKIN Cora FTKM20Q2VMA - Basic Operation - 1

AUTO · DRY · COOL · HEAT · FAN Operation ....11

DAIKIN Cora FTKM20Q2VMA - Basic Operation - 2

Adjusting the Airflow Rate .....12

DAIKIN Cora FTKM20Q2VMA - Basic Operation - 3

Adjusting the Airflow Direction .....13

Useful Functions

DAIKIN Cora FTKM20Q2VMA - Useful Functions - 1

COMFORT AIRFLOW Operation .....14

DAIKIN Cora FTKM20Q2VMA - Useful Functions - 2

INTELLIGENT EYE Operation .....15

DAIKIN Cora FTKM20Q2VMA - Useful Functions - 3

POWERFUL Operation ......17

DAIKIN Cora FTKM20Q2VMA - Useful Functions - 4

ECONO / OUTDOOR UNIT QUIET Operation 18

TIMER Operation

DAIKIN Cora FTKM20Q2VMA - TIMER Operation - 1

ON/OFF TIMER Operation .....19

DAIKIN Cora FTKM20Q2VMA - TIMER Operation - 2

WEEKLY TIMER Operation ......22

Care

Care and Cleaning 28

When the Need Arises

FAQ 32

Troubleshooting 33

Safety Precautions

DAIKIN Cora FTKM20Q2VMA - Safety Precautions - 1

Read the precautions in this manual carefully before operating the unit.

DAIKIN Cora FTKM20Q2VMA - Safety Precautions - 2

This appliance is filled with R32.

  • Keep this manual where the user can easily find it.
  • The precautions described herein are classified as WARNING and CAUTION. They both contain important information regarding safety. Be sure to observe all precautions without fail.

DAIKIN Cora FTKM20Q2VMA - Safety Precautions - 3

WARNING

Failure to follow these instructions properly may result in personal injury or loss of life.

DAIKIN Cora FTKM20Q2VMA - Safety Precautions - 4

CAUTION

Failure to observe these instructions properly may result in property damage or personal injury, which may be serious depending on the circumstances.

DAIKIN Cora FTKM20Q2VMA - Safety Precautions - 5

Never attempt.

DAIKIN Cora FTKM20Q2VMA - Safety Precautions - 6

Be sure to follow the instructions.

DAIKIN Cora FTKM20Q2VMA - Safety Precautions - 7

Be sure to establish an earth connection.

- After reading, keep this manual in a convenient place so that you can refer to it whenever necessary. If the equipment is transferred to a new user, be sure also to hand over the manual.

DAIKIN Cora FTKM20Q2VMA - Safety Precautions - 8

WARNING

DAIKIN Cora FTKM20Q2VMA - WARNING - 1

  • Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
  • The appliance must be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater).
  • Do not pierce or burn.
  • Be aware that refrigerants may not contain an odour.
  • The appliance must be installed, operated and stored in a room with floor area larger than -^*m^2 for 20/25/35/46 class.
    * Since the maximum refrigerant charge of the models is below 1.84kg , it does not have any limitation for the minimum floor area. Maintain an installation height of 1.8m or more from the floor surface to the bottom of the appliance. If the size of the room where the appliance is to be installed has less than the indicated minimum floor area, install it in a well ventilated room. For details refer to the WARNING list in the "Safety Precautions" section of the installation manual for the outdoor unit.
    • To avoid fire, explosion or injury, do not operate the unit when harmful gases (e.g. flammable or corrosive) are detected near the unit.
  • Be aware that prolonged, direct exposure to cool or warm air from the air conditioner, or to air that is too cool or too warm, can be harmful to your physical condition and health.
  • Do not place objects, including rods, your fingers, etc., in the air inlet or outlet. Product damage or personal injury may result due to contact with the air conditioner's high-speed fan blades.
  • Do not attempt to repair, dismantle, reinstall or modify the air conditioner yourself as this may result in water leakage, electric shock or fire hazards.
  • Do not use flammable spray near the air conditioner, or otherwise fire may result.
  • Do not use a refrigerant other than the one indicated on the outdoor unit (R32) when installing, moving or repairing. Using other refrigerants may cause trouble or damage to the unit, and personal injury.
    • To avoid electric shock, do not operate with wet hands.

DAIKIN Cora FTKM20Q2VMA - WARNING - 2

- Beware of fire in case of refrigerant leakage. If the air conditioner is not operating correctly, i.e. not generating cool or warm air, refrigerant leakage could be the cause. Consult your dealer for assistance. The refrigerant within the air conditioner is safe and normally does not leak. However, in the event of a leakage, contact with a naked burner, heater or cooker may result in generation of noxious gas. Do not use the air conditioner until a qualified service person confirms that the leakage has been repaired.

  • Do not attempt to install or repair the air conditioner yourself. Improper workmanship may result in water leakage, electric shock or fire hazards. Please contact your local dealer or qualified personnel for installation and maintenance work.
  • If the air conditioner is malfunctioning (giving off a burning odour, etc.), turn off power to the unit and contact your local dealer. Continued operation under such circumstances may result in a failure, electric shock or fire hazards.
  • Be sure to install an earth leakage circuit breaker. Failure to install an earth leakage circuit breaker may result in electric shock or fire.

DAIKIN Cora FTKM20Q2VMA - WARNING - 3

- Be sure to earth the unit. Do not earth the unit to a utility pipe, lightning conductor or telephone earth lead. Imperfect earthing may result in electric shock.

DAIKIN Cora FTKM20Q2VMA - WARNING - 4

CAUTION

DAIKIN Cora FTKM20Q2VMA - CAUTION - 1

  • Do not use the air conditioner for purposes other than those for which it is intended. Do not use the air conditioner for cooling precision instruments, food, plants, animals or works of art as this may adversely affect the performance, quality and/or longevity of the object concerned.
  • Do not expose plants or animals directly to the airflow from the unit as this may cause adverse effects.
  • Do not place appliances that produce naked flames in places exposed to the airflow from the unit as this may impair combustion of the burner.
  • Do not block the air inlets nor outlets. Impaired airflow may result in insufficient performance or trouble.

DAIKIN Cora FTKM20Q2VMA - CAUTION - 2

  • Do not sit on the outdoor unit, put things on the unit, or pull the unit. Doing so may cause accidents, such as falling or toppling down, thus resulting in injury, product malfunctioning, or product damage.
  • Do not place objects that are susceptible to moisture directly beneath the indoor or outdoor units. Under certain conditions, condensation on the main unit or refrigerant pipes, air filter dirt or drain blockage may cause dripping, resulting in fouling or failure of the object concerned.
  • After prolonged use, check the unit stand and its mounts for damage. If they are left in a damaged condition, the unit may fall and cause injury.
  • To avoid injury, do not touch the air inlet or aluminium fins of the indoor or outdoor units.
  • The appliance is not intended for use by unattended young children or infirm persons. Impairment of bodily functions and harm to health may result.
  • Children should be supervised to ensure that they do not play with the unit or its remote controller. Accidental operation by a child may result in impairment of bodily functions and harm health.
  • Avoid impacts to the indoor and outdoor units, or otherwise product damage may result.
  • Do not place flammable items, such as spray cans, within 1m of the air outlet.
    The spray cans may explode as a result of hot air from the indoor or outdoor units.
  • Be careful not to let pets urinate on the air conditioner. Urination on the air conditioner may result in electric shock or fire.
  • Do not wash the air conditioner with water, as this may result in electric shock or fire.
  • Do not place water containers (vases, etc.) above the unit, as this may result in electric shock or fire hazards if they should topple over.
  • Do not insert the batteries in the wrong polarity (+/-) orientation as this may result in short circuiting, fire, or battery leakage.
  • Do not sit or hang on the panel. The panel may fall, and injury or product malfunctioning may result.
  • Do not sway the panel. The panel may hit people or objects, and injury or property damage may result.
  • Do not let children play around the panel. Injury or property damage may result.
  • Do not pull the wires. The wires may be broken and the panel may fall, and injury or property damage may result.
  • Do not locate obstacles in the route. The panel may fall, and injury or property damage may result.
  • Do not bend or damage the wires. The wires may be broken and the panel may fall, and injury or property damage may result.
  • Do not put objects on the panel, or otherwise production malfunctioning may result.
  • Do not use an unstable stand at the time of operating or maintaining the air conditioner, or otherwise you may topple over or injury yourself.
  • Locate the remote controller in places out of reach of children. The wrong operation of the remote controller may result in injury.

DAIKIN Cora FTKM20Q2VMA - CAUTION - 3

  • To avoid oxygen depletion, ensure that the room is adequately ventilated if equipment such as a burner is used together with the air conditioner.
  • Before cleaning, be sure to stop unit operation and turn off the circuit breaker. Otherwise, an electric shock and injury may result.
  • Only connect the air conditioner to the specified power supply circuit. Power supplies other than the one specified may result in electric shock, overheating and fires.
  • Arrange the drain hose to ensure smooth drainage. Imperfect drainage may cause wetting of the building, furniture, etc.
  • Do not place objects in direct proximity of the outdoor unit and do not let leaves and other debris accumulate around the unit. Leaves are a hotbed for small animals which can enter the unit. Once inside the unit, such animals can cause malfunctions, smoke or fire if they come into contact with electrical parts.
  • Do not place objects around the indoor unit.
    Doing so may have an adverse influence on the performance, product quality, and life of the air conditioner.
  • This appliance is not intended to be used by persons with reduced physical, sensory or mental capabilities, or with lack of operation knowledge, unless they have been given supervision or instruction concerning the appliance use by person responsible for their safety. Keep out of children's reach to ensure that they do not play with the appliance.

Precautions relating to area surrounding the indoor and outdoor units

■ Be sure to follow the instructions below.

- The indoor unit is at least 1m away from any television or radio set (unit may cause interference with the picture or sound).

- Refrain from using the units in areas prone to high levels of oily smoke, such as a kitchen. Water leakage may result.

Names of Parts

Indoor Unit

DAIKIN Cora FTKM20Q2VMA - Indoor Unit - 1

text_image Front panel Air inlet Flap (horizontal blade) ▶Page 13 Louvres (vertical blades) • The louvres are inside of the air outlet. ▶Page 13 Air outlet Model name INTELLIGENT EYE sensor • Detects the movements of people and automatically switches between normal operation and energy saving operation. ▶Page 15,16 Room temperature sensor • Detects the air temperature around the unit.

Display

Signal receiver

  • Receives signals from the remote controller.
  • When the unit receives a signal, you will hear a beep sound.
Case Sound type
Operation start beep-beep
Setting changed beep
Operation stop long beep

DAIKIN Cora FTKM20Q2VMA - Signal receiver - 1

text_image OPERATION lamp (green) TIMER lamp (orange) ON/OFF ►Page 19,20,21,24,26 INTELLIGENT EYE lamp (green) ►Page 15

Indoor unit ON/OFF switch

  • Press this switch once to start operation. Press once again to stop it.
  • For the operation mode setting, refer to the following table.
Mode Temperature setting Airflow rate
AUTO 25.0°C AUTO

- This switch can be used when the remote controller is missing or out of batteries.

■ Open the front panel
DAIKIN Cora FTKM20Q2VMA - Indoor unit ON/OFF switch - 1

text_image Deodorizing filter (enzyme blue) Air filter

Outdoor Unit

■ For 20/25/35 class
DAIKIN Cora FTKM20Q2VMA - Outdoor Unit - 1

text_image Air inlet (back and side) Outdoor temperature sensor (back) Air outlet Earth terminal (inside) Refrigerant pipes and inter-unit wire Drain hose

For 46 class

DAIKIN Cora FTKM20Q2VMA - Outdoor Unit - 2

text_image Air inlet (back and side) Outdoor temperature sensor (back) Refrigerant pipes and inter-unit wire Earth terminal (inside) Drain hose Air outlet

Names of Parts

Remote Controller

DAIKIN Cora FTKM20Q2VMA - Remote Controller - 1

text_image Signal transmitter Receiver To use the remote controller, aim the transmitter at the indoor unit. If there is anything blocking the signals between the unit and the remote controller, such as a curtain, the unit may not operate. The maximum transmission distance is about 7m. Display (LCD) • Displays the current settings. (In this illustration, each section is shown with all its displays on for the purpose of explanation.) TEMPERATURE adjustment button • Changes the temperature setting. ▶Page 11 FAN setting button • Selects the airflow rate setting. ▶Page 12 POWERFUL button • POWERFUL operation. ▶Page 17 ON/OFF button • Press this button once to start operation. Press once again to stop it. ▶Page 11 Front cover • Open the front cover. ▶Page 8 Model name ARC466A26

■ Open the front cover
DAIKIN Cora FTKM20Q2VMA - Remote Controller - 2

text_image MODE selector button • Selects the operation mode. (AUTO/DRY/COOL/HEAT/FAN) ▶ Page 11 ECONO/QUIET button • ECONO/OUTDOOR UNIT QUIET operation. ▶ Page 18 SENSOR button • INTELLIGENT EYE operation. ▶ Page 15 COMFORT button • COMFORT AIRFLOW operation. ▶ Page 14 OFF TIMER button (NIGHT SET mode) ▶ Page 20 TIMER CANCEL button • Cancels the timer setting. ▶ Page 19,20 • Cannot be used for the WEEKLY TIMER operation. SELECT button • Changes the clock, ON/OFF TIMER and WEEKLY TIMER settings.

Preparation Before Operation

DAIKIN Cora FTKM20Q2VMA - Preparation Before Operation - 1

CAUTION

Incorrect handling of batteries can result in injury from battery leakage, rupturing or heating, or lead to equipment failure.

Please observe the following precautions and use safely.

  • If the alkaline solution from the batteries should get in the eyes, do not rub the eyes. Instead, immediately flush the eyes with tap water and seek the attention of a medical professional.
  • Keep batteries out of reach of children. In the event that batteries are swallowed, seek the immediate attention of a medical professional.
  • Do not expose batteries to heat or fire. Do not disassemble or modify batteries. The insulation or gas release vent inside the battery may be damaged, resulting in battery leakage, rupturing, or heating.
  • Do not damage or peel off labels on the batteries.

■ To insert the batteries

  1. Slide the front cover to take it off.
  2. Insert 2 dry batteries AAA.LR03 (alkaline).
  3. Replace the front cover.

■ To fix the remote controller holder to a wall

  1. Choose a place from where the signals reach the unit.
  2. Fix the holder to a wall, a pillar, or similar location with the screws supplied with the holder.
  3. Place the remote controller in the remote controller holder.

■ To attach the deodorizing filter (enzyme blue)

  • If attaching the separately sold filters, attach them before turning the power on.

■ Turn on the circuit breaker

- After the power is turned on, the flap of the indoor unit opens and closes once to set the reference position.

DAIKIN Cora FTKM20Q2VMA - ■ Turn on the circuit breaker - 1

text_image 1 2 3 Position + and - correctly!

DAIKIN Cora FTKM20Q2VMA - ■ Turn on the circuit breaker - 2

text_image Remote controller Screws Remote controller holder

NOTE

Notes on batteries

  • To avoid possible injury or damage from battery leakage or rupturing, remove the batteries when not using the product for long periods of time.
  • The standard replacement time is 1 year. Both batteries should be replaced at the same time. Be sure to replace them with new size AAA. LR03 (alkaline) batteries.
  • When battery power has run out, the LCD will begin blinking as an alert that the batteries need replacing. In some cases, when battery consumption is accelerated owing usage conditions, signal reception may decline before the LCD begins blinking.
  • The batteries supplied with the remote controller are for initial operation. The batteries may run out in less than 1 year.

Note on remote controller

- Do not drop the remote controller. Do not get it wet.

DAIKIN Cora FTKM20Q2VMA - Note on remote controller - 1

text_image MON 15:30 27.0 Select Timer

■ To set the clock

1. Press

DAIKIN Cora FTKM20Q2VMA - Press - 1

" 0.00 appears on the LCD.

"MON" and "💡 blink.

2. Press to set the current day of the week.

3. Press

DAIKIN Cora FTKM20Q2VMA - Press - 1

" blinks.

4. Press to set the clock to the present time.

- Holding down ▲ or rapidly increases or decreases the displayed time.

5. Press ⏰

- Point the remote controller at the indoor unit when pressing the buttons.

DAIKIN Cora FTKM20Q2VMA - Press ⏰ - 1

“*” blinks.

NOTE

Note on setting the clock

- If the indoor unit's internal clock is not set to the correct time, the ON/OFF TIMER and WEEKLY TIMER will not operate punctually.

DAIKIN Cora FTKM20Q2VMA - NOTE - 1

text_image ON 27.0°C * A MON 15:30 On/Off Temp Mode Timer

The air conditioner operates with the operation mode of your choice.

From the next time on, the air conditioner will operate with the same operation mode.

■ To start

1. Press and select an operation mode.

• Each pressing of the button changes the mode setting in sequence.

DAIKIN Cora FTKM20Q2VMA - Press and select an operation mode. - 1

flowchart
graph LR
    A["Input"] --> B["Process Step 1"]
    B --> C["Process Step 2"]
    C --> D["Process Step 3"]
    D --> E["Output"]

2. Press On/Off

• " Off pears on the LCD.
• The OPERATION lamp lights green.

DAIKIN Cora FTKM20Q2VMA - Press On/Off - 1
Display

■ To stop

Press again.

• " ON appears from the LCD.
• The OPERATION lamp goes off.

■ To change the temperature setting

Press

DAIKIN Cora FTKM20Q2VMA - Press - 1

- Press ▲ to raise the temperature and press ▼ to lower the temperature.

Each pressing of the button changes the temperature by 0.5^ C.

COOL operationHEAT operationAUTO operationDRY or FAN operation
18.0-32.0°C10.0-30.0°C18.0-30.0°CThe temperature setting cannot be changed.

NOTE

Notes on AUTO operation

  • In AUTO operation, the system selects an appropriate operation mode (COOL or HEAT) based on the indoor temperature, then starts the operation.
  • The system automatically reselects setting at a regular interval to bring the indoor temperature to user-setting level.

Note on COOL operation

  • This air conditioner cools the room by releasing the heat in the room outside.
    Therefore, the cooling performance of the air conditioner may be degraded if the outdoor temperature is high.

Note on DRY operation

- Eliminates humidity while maintaining the indoor temperature as much as possible. It automatically controls temperature and airflow rate, so manual adjustment of these functions is unavailable.

Notes on HEAT operation

  • Since this air conditioner heats the room by taking heat from outdoor air to indoors, the heating capacity becomes smaller in lower outdoor temperatures. If the heating effect is insufficient, it is recommended to use another heating appliance in combination with the air conditioner.
  • The heat pump system heats the room by circulating hot air around all parts of the room. After the start of HEAT operation, it takes some time before the room gets warmer.
  • In HEAT operation, frost may occur on the outdoor unit and lower the heating capacity. In that case, the system switches into defrosting operation to take away the frost.

Note on FAN operation

• This mode is valid for fan only.

DAIKIN Cora FTKM20Q2VMA - Note on FAN operation - 1

Adjusting the Airflow Rate

DAIKIN Cora FTKM20Q2VMA - Adjusting the Airflow Rate - 1

text_image 27.0°C MON 15:30 Fan

You can adjust the airflow rate to increase your comfort.

■ To adjust the airflow rate setting

DAIKIN Cora FTKM20Q2VMA - ■ To adjust the airflow rate setting - 1

• Each pressing of the button changes the airflow rate setting in sequence.

DAIKIN Cora FTKM20Q2VMA - ■ To adjust the airflow rate setting - 2

flowchart
graph LR
    A["AUTO Indoor unit quiet Airflow rate 1-5 (Low to High)"] --> B["..."]
    B --> C["..."]
    C --> D["..."]
    D --> E["..."]
    E --> F["..."]
    F --> G["..."]
    G --> H["..."]
  • When the airflow is set to “quiet operation starts and noise from the indoor unit will become quieter.
  • In the quiet operation mode, the airflow rate is set to a weak level.
  • In DRY operation, the airflow rate setting cannot be changed.
  • At smaller airflow rates, the cooling (heating) effect is also smaller.

Tips for saving energy

Keeping the temperature setting at a moderate level helps save energy.

- Recommended temperature setting for cooling: 26.0-28.0°C, for heating: 20.0-24.0°C

Cover windows with a blind or a curtain.

- Blocking sunlight and air from outdoors increases the cooling (heating) effect.

Keep the air filters clean.

• Clogged air filters cause inefficient operation and waste energy. Clean them once in about every 2 weeks. ▶ Page 29

If you are not going to use the air conditioner for a long period, for example in spring or autumn, turn off the circuit breaker.

- The air conditioner always consumes a small amount of electricity even while it is not operating.

DAIKIN Cora FTKM20Q2VMA - Tips for saving energy - 1

Adjusting the Airflow Direction

DAIKIN Cora FTKM20Q2VMA - Adjusting the Airflow Direction - 1

text_image 27.0°C MON 15:30 Swing Timer

You can adjust the airflow direction to increase your comfort.

ATTENTION

• Always use a remote controller to adjust the angles of the flap and louvres.

  • If you attempt to move the flap and louvres forcibly by hand when they are swinging, the mechanism may be damaged.
  • Inside the air outlet, a fan is rotating at a high speed.

■ To start auto swing

Up and down airflow direction

Press

• “ Appears on the LCD.
• The flap (horizontal blade) will begin to swing.

Right and left airflow direction

Press

• “ appears on the LCD.
- The louvres (vertical blades) will begin to swing.

The 3-D airflow direction

Press and .

• “ and ” appear on the LCD.
• The flap and louvres move in turn.
- To cancel 3-D airflow, press either 📁 or again.

The flap or louvres will stop moving.

DAIKIN Cora FTKM20Q2VMA - Press and . - 1

natural_image Diagram showing a circular icon with rotation arrows and a rectangular device emitting motion (no text or symbols)

DAIKIN Cora FTKM20Q2VMA - Press and . - 2

text_image Diagram illustrating airflow or fluid flow with a pipe and a cylinder, showing directional arrows and a schematic symbol.

DAIKIN Cora FTKM20Q2VMA - Press and . - 3

natural_image Diagram showing airflow around a vehicle with curved arrows indicating direction (no text or symbols)

■ To set the flap or louvres at the desired position

- This function is effective while the flap or louvres are in auto swing mode.

Press and when the flap or louvres reach the desired position.

• In the 3-D airflow, the flap and louvres move in turn.
- “ 📋” or “ 📄” disappears from the LCD.

NOTE

Note on airflow direction setting

- The movable range of the flap varies according to the operation mode.

Note on 3-D airflow

- Using 3-D airflow circulates cold air, which tends to collect at the bottom of the room, and hot air, which tends to collect near the ceiling, throughout the room, preventing areas of cold and hot developing.

Movable range of the flap
DAIKIN Cora FTKM20Q2VMA - Note on 3-D airflow - 1

text_image e of the flap COOL / DRY FAN HEAT

DAIKIN Cora FTKM20Q2VMA - Note on 3-D airflow - 2

COMFORT AIRFLOW Operation

DAIKIN Cora FTKM20Q2VMA - COMFORT AIRFLOW Operation - 1

text_image 27.0°C MUN 15:30 Comfort Timer

The flow of air will be in the upward direction while in COOL operation and in the downward direction while in HEAT operation, which will provide a comfortable wind that will not come in direct contact with people.

DAIKIN Cora FTKM20Q2VMA - COMFORT AIRFLOW Operation - 2

natural_image Diagram of a airflow or ventilation system with a fan and duct (no text or symbols)

COOL operation

DAIKIN Cora FTKM20Q2VMA - COMFORT AIRFLOW Operation - 3

natural_image Pure diagram of a curved pipe or duct with no text, numbers, or symbols

HEAT operation

■ To start

DAIKIN Cora FTKM20Q2VMA - ■ To start - 1

Press

Comfort

DAIKIN Cora FTKM20Q2VMA - Press - 1

• “ 🙏 appears on the LCD.

COOL and DRY operationHEAT operation FANoperation
Flap directionGoes up Goes downNot available
Airflow rate AUTO

■ To cancel

DAIKIN Cora FTKM20Q2VMA - ■ To cancel - 1

Press

Comfort

DAIKIN Cora FTKM20Q2VMA - Press - 1

again.

• “ disappears from the LCD.
- The flap will return to the position in memory from before COMFORT AIRFLOW operatoin.

NOTE

Notes on COMFORT AIRFLOW Operation

  • The flap position will change, preventing air from blowing directly on the occupants of the room.
  • POWERFUL operation and COMFORT AIRFLOW operation cannot be used at the same time.
    • The airflow rate will be set to AUTO.
  • If the upward and downward airflow direction is selected, the COMFORT AIRFLOW function will be canceled.
    Priority is given to the function of whichever button is pressed last.

DAIKIN Cora FTKM20Q2VMA - Notes on COMFORT AIRFLOW Operation - 1

INTELLIGENT EYE Operation

DAIKIN Cora FTKM20Q2VMA - INTELLIGENT EYE Operation - 1

text_image 27.0°C MON 15:30 Sensor Timer

The INTELLIGENT EYE sensor detects human movement and adjusts airflow direction. It can be set to avoid people or to direct airflow specifically at people. If no one is in the room for more than 20 minutes, the operation automatically changes to energy saving operation.

DAIKIN Cora FTKM20Q2VMA - INTELLIGENT EYE Operation - 2

CAUTION

  • Do not place large objects near the INTELLIGENT EYE sensor. Also keep heating units and humidifiers outside the sensor's detection area. This sensor can detect undesirable objects.
  • Do not hit or violently push the INTELLIGENT EYE sensor. This can lead to damage and malfunction.

■ To start

Press / sensor and select the desired mode.

• Each time the button is pressed, a different setting option appears on the LCD.
• The INTELLIGENT EYE lamp lights green.

DAIKIN Cora FTKM20Q2VMA - Press / sensor and select the desired mode. - 1

text_image Display

DAIKIN Cora FTKM20Q2VMA - Press / sensor and select the desired mode. - 2

flowchart
graph LR
    A["Directly on people"] --> B["Blow directly on people"]
    B --> C["blank\nNo Setting Do not blow"]
  • When the flap (horizontal blade) is swinging, selecting any of the modes above will cause the flap (horizontal blade) to stop.
  • The lamp lights when human movement is detected.

■ To cancel

Press Sensor until no icon is displayed.

• The INTELLIGENT EYE lamp goes off.

NOTE

Note on INTELLIGENT EYE operation

  • INTELLIGENT EYE operation is set to blow directly on people, the air conditioner tracks you horizontally, without the air blowing directly on you.
  • When the INTELLIGENT EYE sensor detects the movement of people, it adjusts the airflow direction upward (while in COOL operation) and downward (while in HEAT operation), by adjusting the flap. Depending on the setting, the louvres (vertical blades) will either direct airflow directly toward or away from people.

■ How the INTELLIGENT EYE operation works

The INTELLIGENT EYE sensor detects human movement and adjusts the right and left airflow direction. If no one is in the room for more than 20 minutes, the operation automatically changes to energy saving operation. The INTELLIGENT EYE sensor works differently depending on the situation.

[Example]

A person is detected in area 1. area 2.A person is detected inPeople are detected in both areas.No people are detected in the areas.
DAIKIN Cora FTKM20Q2VMA - ■ How the INTELLIGENT EYE operation works - 1DAIKIN Cora FTKM20Q2VMA - ■ How the INTELLIGENT EYE operation works - 2DAIKIN Cora FTKM20Q2VMA - ■ How the INTELLIGENT EYE operation works - 3The airflow is directed to Area 1.DAIKIN Cora FTKM20Q2VMA - ■ How the INTELLIGENT EYE operation works - 4DAIKIN Cora FTKM20Q2VMA - ■ How the INTELLIGENT EYE operation works - 5
DAIKIN Cora FTKM20Q2VMA - ■ How the INTELLIGENT EYE operation works - 6DAIKIN Cora FTKM20Q2VMA - ■ How the INTELLIGENT EYE operation works - 7DAIKIN Cora FTKM20Q2VMA - ■ How the INTELLIGENT EYE operation works - 8The current airflow direction is maintained.The air conditioner will switch to energy-saving mode after 20 minutes.

* The airflow direction may differ from the illustrated direction depending on the actions and movements of the people in the areas.

INTELLIGENT EYE operation is useful for energy saving

Energy saving operation

  • If no presence detected in the room for 20 minutes, the energy saving operation will start, and the INTELLIGENT EYE lamp goes off. If human movement is detected again, the INTELLIGENT EYE lamp lights up and energy saving operation terminates.
  • This operation changes the temperature by -2^ in HEAT / +2^ in COOL / +2^ in DRY operation from the set temperature. When the room temperature exceeds 30^ , the operation changes the temperature by +1^ in COOL / +1^ in DRY operation from the set temperature.
  • This operation decreases the airflow rate slightly in FAN operation only.

NOTE

Notes on INTELLIGENT EYE operation

- Application range is as follows.

DAIKIN Cora FTKM20Q2VMA - Notes on INTELLIGENT EYE operation - 1

text_image Vertical angle 90° (Side view) 5m 90°

DAIKIN Cora FTKM20Q2VMA - Notes on INTELLIGENT EYE operation - 2

text_image Horizontal angle 110° (Top view) 55° 55° 5m
  • While the air conditioner is in INTELLIGENT EYE operation, the louvres adjust the airflow direction if there are people in the sensing areas of the INTELLIGENT EYE so that the leftward or rightward airflow will not be directed to the people.
    If no people are detected in either area 1 or 2 for 20 minutes, the air conditioner switches to the energy-saving mode with the set temperature shifted by 2^ C.
    The air conditioner may switch to the energy-saving operation even if there are people in the areas.
    This may occur depending on the clothes the people are wearing, if there is no movement of the people in the areas.
  • The airflow direction from the louvres will be leftward if there are people in both areas 1 and 2. The air will also flow left if there is a person right in front of the sensor as the sensor judges that there are people in both areas.
  • Due to the position of the sensor, people might be exposed to the airflow of the indoor unit if they are close to the front side of the indoor unit. If there are people close to the front side of the indoor unit or in both areas, it is recommended to use the COMFORT AIRFLOW and INTELLIGENT EYE operations simultaneously. Using both modes together, the air conditioner will not direct the airflow towards the people.
    • The sensor could also mistakenly detect pets, sunlight, fluttering curtains and light reflected off of mirrors as passers-by.
  • The sensor may not detect moving objects further than 5m away. (Please see the application range)
  • Sensor detection sensitivity changes according to the indoor unit location, the speed of passers-by, temperature range, etc.
  • NIGHT SET mode ▶Page 20 will not switch on during use of INTELLIGENT EYE operation.

DAIKIN Cora FTKM20Q2VMA - Notes on INTELLIGENT EYE operation - 3

POWERFUL Operation

DAIKIN Cora FTKM20Q2VMA - POWERFUL Operation - 1

text_image 15:30 Powerful

POWERFUL operation quickly maximises the cooling (heating) effect in any operation mode. In this mode, the air conditioner operates at maximum capacity.

■ To start

Press during operation.

• “ appears on the LCD.
- POWERFUL operation ends in 20 minutes. Then the system automatically operates again with the previous settings which were used before POWERFUL operation.

■ To cancel

Press again.

• “ disappears from the LCD.

NOTE

Notes on POWERFUL operation

  • Pressing causes the settings to be cancelled, and " " disappears from the LCD.
  • POWERFUL operation will not increase the capacity of the air conditioner if the air conditioner is already in operation with its maximum capacity demonstrated.
  • In COOL, HEAT and AUTO operation
    To maximise the cooling (heating) effect, the capacity of outdoor unit increases and the airflow rate becomes fixed at the maximum setting. The temperature and airflow settings cannot be changed.
  • In DRY operation
    The temperature setting is lowered by 2.5°C and the airflow rate is slightly increased.
  • In FAN operation
    The airflow rate is fixed at the maximum setting.

Regarding the combination of POWERFUL and other operations

POWERFUL + COMFORT AIRFLOWNot available*
POWERFUL + ECONO
POWERFUL + OUTDOOR UNIT QUIET

*Priority is given to the function of whichever button is pressed last.

DAIKIN Cora FTKM20Q2VMA - Notes on POWERFUL operation - 1

ECONO / OUTDOOR UNIT QUIET Operation

DAIKIN Cora FTKM20Q2VMA - ECONO / OUTDOOR UNIT QUIET Operation - 1

text_image 27.0 MON 15:30 Erons Chout Tieter

ECONO operation enables efficient operation by limiting the maximum power consumption. This function is useful to prevent the circuit breaker from tripping when the unit operates alongside other appliances on the same circuit.

OUTDOOR UNIT QUIET operation lowers the noise level of the outdoor unit by changing the frequency and fan speed of the outdoor unit. This function is convenient during the night-time operation.

■ To start

Press Econo/Quiet and select the desired mode.

• Each time the button is pressed, a different setting option appears on the LCD.

DAIKIN Cora FTKM20Q2VMA - Press Econo/Quiet and select the desired mode. - 1

flowchart
graph LR
    A["ECONO OUTDOOR UNIT QUIET"] --> B["Combination"]
    B --> C["blank\nNo Setting"]

■ To cancel

Press Econo/Quiet until no icon is displayed.

NOTE

Notes on ECONO operation

  • This operation is performed with lower power and therefore may not provide a sufficient cooling (heating) effect.
  • Pressing ⏻ causes the settings to be cancelled, and “” disappears from the LCD.
  • If the power consumption level is already low, switching to ECONO operation will not reduce the power consumption.

Notes on OUTDOOR UNIT QUIET operation

  • Even if the operation is stopped by using the remote controller or the indoor unit ON/OFF switch when using OUTDOOR UNIT QUIET operation, "💡" will remain displayed on the remote controller.
  • OUTDOOR UNIT QUIET operation will not reduce the frequency nor fan speed if they already are operating at reduced levels.
  • This operation is performed with lower power and therefore may not provide a sufficient cooling (heating) effect.

Possible combinations of ECONO / OUTDOOR UNIT QUIET operation and basic operations

Operation mode
DRY COOLHEAT FAN
ECONO-
OUTDOOR UNIT QUIET--

DAIKIN Cora FTKM20Q2VMA - Notes on OUTDOOR UNIT QUIET operation - 1

ON/OFF TIMER Operation

DAIKIN Cora FTKM20Q2VMA - ON/OFF TIMER Operation - 1

text_image 27.0 ON 6:00 Select Cancel On Timer

Timer functions are useful for automatically switching the air conditioner on or off at night or in the morning. You can also use the ON TIMER and OFF TIMER together.

[ON TIMER with a 24 hour clock display] (24 HOUR ON/OFF TIMER)

■ To set

- Check that the clock is correct.

If not, set the clock to the present time. ▶Page 10

1. Press On

DAIKIN Cora FTKM20Q2VMA - Press On - 1

“5.00 appears on the LCD.

"ON" blinks.

- “④” and day of the week disappear from the LCD.

2. Press until the time setting reaches the point you like.

- Each pressing of either button increases or decreases the time setting by 10 minutes. Holding down either button changes the setting rapidly.

3. Press on again.

- “ON” and setting time appear on the LCD.

• The TIMER lamp lights orange.

DAIKIN Cora FTKM20Q2VMA - Press on again. - 1
Display

■ To cancel

Press Cancel.

  • “ON” and setting time disappear from the LCD.
  • “ ⊕” and day of the week appear on the LCD.
    • The TIMER lamp goes off.

NOTE

Note on TIMER operation

- When TIMER is set, the present time is not displayed.

In the following cases, set the timer again.

• After the circuit breaker has turned off.
• After a power failure.
• After replacing the batteries in the remote controller.

DAIKIN Cora FTKM20Q2VMA - In the following cases, set the timer again. - 1

text_image 27.0 OFF 0:00 Off Select Cancel Timer

[OFF TIMER with a 24 hour clock display] (24 HOUR ON/OFF TIMER)

■ To set

- Check that the clock is correct. If not, set the clock to the present time. ▶Page 10

1. Press Off

DAIKIN Cora FTKM20Q2VMA - Press Off - 1

"0:appears on the LCD. "OFF" blinks.

- “ ⊕” and day of the week disappear from the LCD.

2. Press until the time setting reaches the point you like.

• Each pressing of either button increases or decreases the time setting by 10 minutes. Holding down either button changes the time setting rapidly.

3. Press again.

- “OF and setting time appear on the LCD. - The TIMER lamp lights orange.

DAIKIN Cora FTKM20Q2VMA - Press again. - 1
Display

■ To cancel

Press Cancel.

  • “OF and setting time disappear from the LCD.
  • “ ⏻” and day of the week appear on the LCD.
    • The TIMER lamp goes off.

[ON/OFF TIMER combination]

■ To combine

- A sample setting for combining the 2 timers is shown below.

DAIKIN Cora FTKM20Q2VMA - ■ To combine - 1

text_image (Example) Present time: 23:00 (The unit is operating) OFF TIMER at 0:00 ON TIMER at 14:00) Combined OFF 0:00 ON 14:00

NOTE

NIGHT SET mode

- When the OFF TIMER is set, the air conditioner automatically adjusts the temperature setting (0.5°C up in COOL, 2.0°C down in HEAT) to prevent excessive cooling (heating) during sleeping hours.

DAIKIN Cora FTKM20Q2VMA - NIGHT SET mode - 1

ON/OFF TIMER Operation

DAIKIN Cora FTKM20Q2VMA - ON/OFF TIMER Operation - 1

text_image ON 27.0°C A ON Ihr Off Select On Cancel Timer

[ON/OFF TIMER with an hours remaining display] (COUNT UP-DOWN ON/OFF TIMER)

- Check that the clock is correct. If not, set the clock to the present time. ▶Page 10

DAIKIN Cora FTKM20Q2VMA - Press and hold on or for about 5 seconds, when signal indicator (▲) blink, release your finger from the button. - 1

For ON TIMER

"Ihr" appears on the LCD.

"ON" blinks.

For OFF TIMER

“Ihr” appears on the LCD.

"OFF" blinks.

- “ ⊕” and day of the week disappear from the LCD.

2. Press until the time setting reaches the point you like.

• Each pressing of the button increases or decreases the time setting by 1 hour.

- The time can be set between 1 and 12 hours.

3. Press on or again. Off

- “ONand” “OFF and setting time appear on the LCD.

• The TIMER lamp lights orange.

- To change the display mode from COUNT UP-DOWN ON/OFF TIMER to 24 HOUR ON/OFF TIMER, repeat STEP 1, and continue from STEP 2 of "24 HOUR ON/OFF TIMER". ▶ Page 19, 20

- Timer display mode cannot be changed while "ON" or "OF" are blinking. Press ☐ or ☑ to stop the blinking.

DAIKIN Cora FTKM20Q2VMA - Press on or again. Off - 1
Display

■ Combining display modes

- Different display modes (24 HOUR ON/OFF TIMER and COUNT UP-DOWN ON/OFF TIMER) can be used for the ON TIMER and OFF TIMER simultaneously.

DAIKIN Cora FTKM20Q2VMA - ■ Combining display modes - 1

text_image (Example) Present time: 22:00 [The unit is operating] OFF TIMER at 1:00 (3 hours after persent time) ON TIMER at 6:00 (8 hours after persent time) )Combined OFF 3hr ON 6:00 OFF 1:00 ON 8hr OFF 3hr ON 8hr

NOTE

Note on COUNT UP-DOWN ON/OFF TIMER

- After setting, the time displayed on the LCD will automatically count down by 1 hour for every 1 hour that passes. For example, if the OFF TIMER is set to 3 hours, the display will change as follows: 3hr 2hr 1hr blank (OFF)

Switching between ON/OFF TIMER display modes (24 hour clock and hours remaining display)

- When changing timer display modes (from 24 HOUR ON/OFF TIMER to COUNT UP-DOWN ON/OFF TIMER or vice versa), the timer cancels. The timer must be set again to activate it.

WEEKLY TIMER Operation

Up to 4 timer settings can be saved for each day of the week. This is convenient to adapt the WEEKLY TIMER to your family's life style.

■ Setting example of the WEEKLY TIMER

The same timer settings are used from Monday through Friday, while different timer settings are used for the weekend.

[Monday]Make timer settings for programmes 1-4. ▶Page 23
Programme 1Programme 2Programme 3Programme 4
DAIKIN Cora FTKM20Q2VMA - ■ Setting example of the WEEKLY TIMER - 1DAIKIN Cora FTKM20Q2VMA - ■ Setting example of the WEEKLY TIMER - 2DAIKIN Cora FTKM20Q2VMA - ■ Setting example of the WEEKLY TIMER - 3DAIKIN Cora FTKM20Q2VMA - ■ Setting example of the WEEKLY TIMER - 4
[Tuesday] to [Friday]Use the copy mode to make settings for Tuesday to Friday, because these settings are the same as those for Monday. ▶Page 25PrDAIKIN Cora FTKM20Q2VMA - ■ Setting example of the WEEKLY TIMER - 5≥4
[Saturday]No timer settings
[Sunday]Make timer settings for programmes 1-4. ▶Page 23DAIKIN Cora FTKM20Q2VMA - ■ Setting example of the WEEKLY TIMER - 6
  • Up to 4 reservations per day and 28 reservations per week can be set using the WEEKLY TIMER. The effective use of the copy mode simplifies timer programming.
  • The use of ON-ON-ON-ON settings, for example, makes it possible to schedule operating mode and set temperature changes. Furthermore, by using OFF-OFF-OFF-OFF settings, only the turn off time of each day can be set. This will turn off the air conditioner automatically if you forget to turn it off.

DAIKIN Cora FTKM20Q2VMA - ■ Setting example of the WEEKLY TIMER - 7

WEEKLY TIMER Operation

DAIKIN Cora FTKM20Q2VMA - WEEKLY TIMER Operation - 1

text_image MOZZER 27.0°C ON MON 6:00 25.0°C Select Next Timer

■ To use WEEKLY TIMER operation

Setting mode

- Make sure the day of the week and time are set. If not, set the day of the week and time. ▶Page 10

DAIKIN Cora FTKM20Q2VMA - Setting mode - 1

text_image [Monday] 25.0°C 27.0°C 6:00 8:30 17:30 22:00 Programme 1 Programme 2 ON OFF Programme 3 ON OFF Programme 4

Setting Displays
DAIKIN Cora FTKM20Q2VMA - Setting mode - 2

flowchart
graph LR
    A["MON"] --> B["ON"]
    B --> C["6:00"]
    C --> D["25.0°C"]

1. Press

- The day of the week and the reservation number of the current day will be displayed. - 1 to 4 settings can be made per day.

2. Press Select to select the desired day of the week and reservation number.

- Pressing Select changes the reservation number and the day of the week.

3. Press Next .

- The day of the week and reservation number will be set. - “WEEKLY” and “ON” blink.

4. Press Select to select the desired mode.

- Pressing Select changes the "ON" or "OFF" setting in sequence.

DAIKIN Cora FTKM20Q2VMA - Press Select to select the desired mode. - 1

flowchart
graph LR
    A["ON"] --> B["OFF"]
    B --> C["blank"]
    D["ON TIMER"] --> A
    E["OFF TIMER"] --> B
    F["No Setting"] --> C

Pressing Select puts the sequence in reverse.

  • In case the reservation has already been set, selecting "blank" deletes the reservation.
  • Proceed to STEP 9 if "blank" is selected.
  • To return to the day of the week and reservation number setting, press ☐.

5. Press Next .

  • The ON/OFF TIMER mode will be set.
    • “ Ⓞ WEEKLY ” and the time blink.

DAIKIN Cora FTKM20Q2VMA - Press Next . - 1

text_image ON 27.0°C A BERLY TUE ON 6:00 25.0°C Select Next Timer

6. Press 📁 to select the desired time.

  • The time can be set between 0:00 and 23:50 in 10-minute intervals.
  • To return to the ON/OFF TIMER mode setting, press BACK
  • Proceed to STEP 9 when setting the OFF TIMER.

7. Press Next

  • The time will be set.
  • “ Ⓧ WEEKLY ” and the temperature blink.

8. Press to select the desired temperature.

  • The temperature can be set between 10.0°C and 32.0°C. COOL or AUTO: The unit operates at 18.0°C even if it is set to 10.0°C to 17.0°C. ▶Page 11 HEAT or AUTO: The unit operates at 30.0°C even if it is set to 31.0°C to 32.0°C. ▶Page 11
  • To return to the time setting, press Back .
  • The set temperature is only displayed when the mode setting is on.

9. Press Next

  • The temperature will be set and go to the next reservation setting.
  • The temperature is set while in ON TIMER operation, and the time is set while in OFF TIMER operation.
  • The next reservation screen will appear.
  • To continue further settings, repeat the procedure from STEP 4.

10. Press to complete the setting.

  • Be sure to direct the remote controller toward the indoor unit and check for a receiving tone and blinking of the OPERATION lamp.
  • “WEEKLY” appears on the LCD and WEEKLY TIMER operation is activated.
    • The TIMER lamp lights orange.

DAIKIN Cora FTKM20Q2VMA - Press to complete the setting. - 1
Display

- A reservation made once can be easily copied and the same settings used for another day of the week. Refer to Copy mode. ▶Page 25

NOTE

Notes on WEEKLY TIMER operation

  • Do not forget to set the clock on the remote controller first. ▶Page 10
  • The day of the week, ON/OFF TIMER mode, time and set temperature (only for ON TIMER mode) can be set with the WEEKLY TIMER. Other settings for the ON TIMER are based on the settings just before the operation.
  • WEEKLY TIMER and ON/OFF TIMER operation cannot be used at the same time. The ON/OFF TIMER operation has priority if it is set while WEEKLY TIMER is still active. The WEEKLY TIMER will enter the standby state, and “ Ⓧ WEEKLY ” will disappear from the LCD. When the ON/OFF TIMER is up, the WEEKLY TIMER will automatically become active.
  • Only the time and set temperature with the WEEKLY TIMER are sent with the ☐. Set the WEEKLY TIMER only after setting the operation mode, the airflow rate and the airflow direction ahead of time.
  • Turning off the circuit breaker, power failure, and other similar events will render operation of the indoor unit's internal clock inaccurate. Reset the clock. ▶ Page 10
    • can be used only for the time and temperature settings. It cannot be used to go back to the reservation number.

DAIKIN Cora FTKM20Q2VMA - Notes on WEEKLY TIMER operation - 1

WEEKLY TIMER Operation

DAIKIN Cora FTKM20Q2VMA - WEEKLY TIMER Operation - 1

text_image 27.0°C ON TUE 6:00 25.0°C Copy Select Timer

Copy mode

- A reservation made once can be copied to another day of the week. The whole reservation of the selected day of the week will be copied.

DAIKIN Cora FTKM20Q2VMA - Copy mode - 1

text_image Programme 1 Programme 2 Programme 3 Programme 4 [Monday] ON OFF ON OFF 25.0°C 27.0°C 6:00 8:30 17:30 22:00 COPY Programme 1 Programme 2 Programme 3 Programme 4 [Tuesday] ON OFF ON OFF 25.0°C 27.0°C 6:00 8:30 17:30 22:00

DAIKIN Cora FTKM20Q2VMA - Copy mode - 2

flowchart
graph LR
    A["Setting Displays"] --> B["Confirmation"]
    B --> C["Copy"]
    C --> D["Paste"]
    D --> E["Normal"]
  1. Press
  2. Press Select to confirm the day of the week to be copied.
  3. Press Copy .

- The whole reservation of the selected day of the week will be copied.

  1. Press Select to select the destination day of the week.
  2. Press Copy

  3. The reservation will be copied to the selected day of the week. The whole reservation of the selected day of the week will be copied.
    • To continue copying the settings to other days of the week, repeat STEP 4 and STEP 5.

  4. Press ☐ to complete the setting.

- “WEEKLY” appears on the LCD and WEEKLY TIMER operation is activated.

NOTE

Note on COPY MODE

- The entire reservation of the source day of the week is copied in the copy mode. In the case of making a reservation change for any day of the week individually after copying the content of weekly reservations, press and change the settings in the steps of Setting mode. ▶Page 23

DAIKIN Cora FTKM20Q2VMA - Note on COPY MODE - 1

text_image ON TUE 6:00 25.0°C Weekly Select Next Timer

■ Confirming a reservation

• The reservation can be confirmed.

DAIKIN Cora FTKM20Q2VMA - ■ Confirming a reservation - 1

text_image Setting Displays TUE 15:30 Normal Confirmation ON 6:00 TUE 25.0°C

1. Press

- The day of the week and the reservation number of the current day will be displayed.

2. Press to select the day of the week and the reservation number to be confirmed.

  • Pressing displays the reservation details.
  • To change the confirmed reserved settings, select the reservation number and press. The mode is switched to setting mode. Proceed to Setting mode STEP 4. ▶Page 23

3. Press to exit the confirmation mode.

  • “ WEEKLYrs on the LCD and WEEKLY TIMER operation is activated.
    • The TIMER lamp lights orange.

DAIKIN Cora FTKM20Q2VMA - Press to exit the confirmation mode. - 1
Display

■ To deactivate WEEKLY TIMER operation

Press ☐ while “ Ⓧ WEEKLY ” is displayed on the LCD.

• “ MEAN bears from the LCD.
• The TIMER lamp goes off.
• To reactivate the WEEKLY TIMER operation, press ____ again.
- If a reservation deactivated with weekly is activated once again, the last reservation mode will be used.

NOTE

- If not all the reservation settings are reflected, deactivate the WEEKLY TIMER operation once. Then press ____ again to reactivate the WEEKLY TIMER operation.

DAIKIN Cora FTKM20Q2VMA - NOTE - 1

WEEKLY TIMER Operation

DAIKIN Cora FTKM20Q2VMA - WEEKLY TIMER Operation - 1

text_image 27.0°C ON TUE 6:00 25.0°C Weekly Select Next Timer

■ To delete a reservation

An individual reservation

1. Press

- The day of the week and the reservation number will be displayed.

2. Press to select the day of the week and the reservation number to be deleted.

3. Press Next

• " WEEKLY " or " ONlink. OFF

4. Press until no icon is displayed.

- Pressing changes the ON/OFF TIMER mode in sequence.

- Selecting "blank" will cancel any reservation you may have.

DAIKIN Cora FTKM20Q2VMA - Press until no icon is displayed. - 1

flowchart
graph LR
    A["ON"] --> B["OFF"]
    B --> C["blank"]
    D["ON TIMER OFF TIMER"] --> E["No Setting"]

Pressing Select puts the sequence in reverse.

5. Press Next .

- The selected reservation will be deleted.

6. Press .

- If there are still other reservations, WEEKLY TIMER operation will be activated.

Reservations for each day of the week

- This function can be used for deleting reservations for each day of the week.

- It can be used while confirming or setting reservations.

1. Press

- The day of the week and the reservation number will be displayed.

2. Press Select to select the day of the week to be deleted.

3. Hold for about 5 seconds.

- The reservation of the selected day of the week will be deleted.

4. Press .

- If there are still other reservations, WEEKLY TIMER operation will be activated.

All reservations

Hold Weekly for about 5 seconds with the normal display.

  • Be sure to direct the remote controller toward the indoor unit and check for a receiving tone.
  • This operation cannot be used for the WEEKLY TIMER setting display.
  • All reservations will be deleted.

Care and Cleaning

DAIKIN Cora FTKM20Q2VMA - Care and Cleaning - 1

CAUTION

  • Before cleaning, be sure to stop the operation and turn off the circuit breaker.
  • Do not touch the aluminum fins of the indoor unit. If you touch those parts, this may cause an injury.

■ Quick reference

Cleaning parts

Front panel

  • Wipe it with a soft damp cloth.
  • Only neutral detergent may be used.

If dirty
DAIKIN Cora FTKM20Q2VMA - Front panel - 1

DAIKIN Cora FTKM20Q2VMA - Front panel - 2

natural_image Cross-sectional diagram of an air conditioner unit showing internal compartments and ventilation slots (no text or labels)

DAIKIN Cora FTKM20Q2VMA - Front panel - 3

DAIKIN Cora FTKM20Q2VMA - Front panel - 4

DAIKIN Cora FTKM20Q2VMA - Front panel - 5

natural_image Two curved, grid-patterned panels with a small dot on one panel (no text or symbols)

Air filter

• Vacuum dust or wash the filter.

Once every 2 weeks

Page 29

Indoor unit and remote controller

- Wipe them with a soft cloth.

If dirty

Deodorizing filter (enzyme blue)

To purchase the filters (Table 1) or to purchase the another type, contact the dealer where you bought the air conditioner.

The method of cleaning and replacement of the filters may differ depending on the model. Refer to the label attached to the separately sold filters themselves.

Table 1

Item Part No.
Air quality filter (enzyme blue with PM2.5) - without frame (set of 2)BAFP094A43
Deodorizing filter (enzyme blue) - without frame (set of 2) BAFP094A41
Dust collection filter (PM 2.5) - without frame (set of 2) BAFP046A41
Titanium apatite deodorizing filter - without frame (set of 2) KAF970A46

Deodorizing filter (enzyme blue), Titanium apatite deodorizing filter.

• Vacuum dust or replace the filter. [Cleaning] [Replacement]

Once every 6 months Once every 3 years

▶Page 30

▶Page 30

Air quality filter (enzyme blue with PM2.5), Dust collection filter (PM 2.5)

- No cleaning is required. Please replace the filter every 6 months. ▶Page 30

NOTE

For cleaning, do not use any of the following:

• Water hotter than 40°C
• Volatile liquid such as benzene, petrol and thinner
- Polishing compounds
- Rough materials such as a scrubbing brush

DAIKIN Cora FTKM20Q2VMA - NOTE - 1

natural_image Illustration of a kettle, a brush, and a bottle (no text or symbols)

Care and Cleaning

Air filter

1. Open the front panel.

- Hold the front panel by the sides and open it.

DAIKIN Cora FTKM20Q2VMA - Open the front panel. - 1

natural_image Diagram of a car air conditioner unit showing airflow direction and ventilation slots (no text or symbols)

2. Pull out the air filters.

- Push the filter tab at the centre of each air filter a little upwards, then pull it down.

DAIKIN Cora FTKM20Q2VMA - Pull out the air filters. - 1

text_image 1) Push 2) Pull down

3. Wash the air filters with water or clean them with vacuum cleaner.

- It is recommended to clean the air filters every 2 weeks.

DAIKIN Cora FTKM20Q2VMA - Wash the air filters with water or clean them with vacuum cleaner. - 1

natural_image Illustration of hands holding a grid-based object with scissors, no text or symbols present

If the dust does not come off easily

- Wash the air filters with neutral detergent thinned with lukewarm water, then dry them up in the shade.

DAIKIN Cora FTKM20Q2VMA - If the dust does not come off easily - 1

natural_image Simple line drawing of a basin with a rectangular object on top (no text or symbols)

4. Reattach the filters.

5. Close the front panel slowly.

- Press the panel at both sides and the centre.

DAIKIN Cora FTKM20Q2VMA - Close the front panel slowly. - 1

natural_image Illustration of a wall-mounted air conditioner unit with three black arrows indicating airflow or cooling direction (no text or symbols)

- Make sure that the front panel is securely fixed.

■ Filter (small)

* For the applicable filter type, please refer to ▶Page 28.

Attaching

  1. Open the front panel and pull out the air filters. ▶ Page 29

  2. Insert the filter.

- Check that the filters are inserted securely under the tabs.

DAIKIN Cora FTKM20Q2VMA - Attaching - 1

text_image Filter (small) Tab

Cleaning and Replacement

  1. Open the front panel and pull out the air filters. ▶ Page 29

  2. Take off the filter.

- Remove the filters from the tabs.

DAIKIN Cora FTKM20Q2VMA - Cleaning and Replacement - 1

text_image Filter (small) Tab
  1. Clean or replace.

[Cleaning]

Deodorizing filter (enzyme blue) : Blue / Titanium apatite deodorizing filter : Blue-Black

3-1 Vacuum dust, and soak in lukewarm water or water for about 10 to 15 minutes if very dirty.

3-2 After washing, shake off remaining water and let them dry in the shade.

- This filter can be renewed by washing it with water once every 6 months and we recommend replacing it once every 3 years. - Do not wiring out the filter when removing water from it.

Air quality filter (enzyme blue with PM2.5) : Blue-White / Dust collection filter (PM 2.5) : White

- Do not wash the filters as this will reduce their efficiency. - It is recommended to replace it once every 6 months.

[Replacement]

Remove each filter from the front grille by detaching them from the 6 tabs and then install the new filters.

- When attaching the filter, check that the filter is properly set in the tabs.

  1. Set the filters as they were and close the front panel.

- Press the front panel at both sides and the center.

NOTE

• Operation with dirty filters:
- cannot deodorise the air,
- cannot clean the air,
– results in poor heating or cooling,
- may cause odour.
- Dispose of old filters as non-flammable waste.

Care and Cleaning

■ Prior to a long period of non-use

  1. Operate the FAN mode for several hours on a fine day to dry out the inside.

1) Press and select " .
2) Press 0-0F and start the operation.
2. After operation stops, turn off the circuit breaker for the room air conditioner.
3. Clean the air filters and reattach them. ▶Page 29
4. To prevent battery leakage, take out the batteries from the remote controller.

■ We recommend periodical maintenance

  • In certain operating conditions, the inside of the air conditioner may get foul after several seasons of use, resulting in poor performance. It is recommended to have periodical maintenance by a specialist in addition to regular cleaning by the user.
  • For specialist maintenance, please contact the dealer where you bought the air conditioner.
  • The maintenance cost must be borne by the user.

FAQ

Indoor unit

The flap does not start swinging immediately.

- The air conditioner is adjusting the position of the flap. The flap will start moving soon.

The air conditioner stops generating airflow during HEAT operation.

- Once the set temperature is reached, the airflow rate is reduced and operation stopped in order to avoid generating a cool airflow. Operation will resume automatically when the indoor temperature falls.

HEAT operation stops suddenly and a flowing sound is heard.

- The outdoor unit is defrosting. HEAT operation starts after the frost on the outdoor unit has been removed. This can take about 4 to 12 minutes.

Operation does not start soon.

■ When ⏻ was pressed soon after operation was stopped.

■ When the mode was reselected.
• This is to protect the air conditioner. You should wait for about 3 minutes.

Outdoor unit

The outdoor unit emits water or steam.

In HEAT operation

  • The frost on the outdoor unit melts into water or steam when the air conditioner is in defrosting operation.
    ■ In COOL or DRY operation
  • Moisture in the air condenses into water on the cool surface of the outdoor unit piping and drips.

Different sounds are heard.

■ A sound like flowing water

  • This sound is generated because the refrigerant in the air conditioner is flowing.
  • This is a pumping sound of the water in the air conditioner and can be heard when the water is pumped out from the air conditioner during COOL or DRY operation.

■ Blowing sound

  • This sound is generated when the flow of the refrigerant in the air conditioner is switched over.
    ■ Ticking sound
  • This sound is generated when the cabinet and frame of the air conditioner slightly expand or shrink as a result of temperature changes.

■ Whistling sound

  • This sound is generated when refrigerant flows during defrosting operation.
    ■ Clicking sound during operation or idle time
  • This sound is generated when the refrigerant control valves or the electrical parts operate.

■ Clopping sound

  • This sound is heard from the inside of the air conditioner when the exhaust fan is activated while the room doors are closed. Open the window or turn off the exhaust fan.
    ■ Rotating machinery causes sound

  • Sound is heard when the vertical swing flaps and the horizontal swing flaps move.

  • When the air conditioner is operating in a quiet environment and the airflow rate of the indoor unit is set to Quiet Mode or Low Mode, the motion of the swing flaps may cause sound.

DAIKIN Cora FTKM20Q2VMA - Different sounds are heard. - 1

natural_image Illustration of a large air conditioner unit with mesh grille and side-mounted buttons (no text or symbols)

Troubleshooting

Before making an inquiry or a request for repair, please check the following.

If the problem persists, consult your dealer.

DAIKIN Cora FTKM20Q2VMA - Troubleshooting - 1

Not a problem

This case is not a problem.

DAIKIN Cora FTKM20Q2VMA - Not a problem - 1

Check

Please check again before requesting repairs.

The air conditioner does not operate

Case Description / what to check
OPERATION lamp is off.Has the circuit breaker been tripped or the fuse blown?Is there a power failure?Are batteries set in the remote controller?
OPERATION lamp is blinking.Turn off the power with the circuit breaker and restart operation with the remote controller.If the OPERATION lamp is still blinking, check the error code and consult your dealer.

The air conditioner suddenly stops operating

Case Description / what to check
OPERATION lamp is on.To protect the system, the air conditioner may stop operating after sudden large voltage fluctuations. It automatically resumes operation in about 3 minutes.
OPERATION lamp is blinking.Is there anything blocking the air inlet or air outlet of the indoor unit or outdoor unit? Stop operation and after turning off the circuit breaker, remove the obstruction. Then restart operation with the remote controller. If the OPERATION lamp is still blinking, check the error code and consult your dealer. ▶Page 36

The air conditioner does not stop operating

Case Description / what to check
The air conditioner continues operating even after operation is stopped.☑ Immediately after the air conditioner is stopped• The outdoor unit fan continues rotating for about another 1 minute to protect the system.• While the air conditioner is not in operation• When the outdoor temperature is high, the outdoor unit fan may start rotating to protect the system.

The room does not cool down/ warm up

Case Description / what to check
Air does not come out.☑ In HEATING operationThe air conditioner is warming up. Wait for about 1 to 4 minutes.During defrosting operation, hot air does not flow out of the indoor unit.When the air conditioner operates immediately after the circuit breaker is turned onThe air conditioner is preparing to operate. Wait for about 3 to 15 minutes.
Air does not come out / Air comes out.? Is the airflow rate setting appropriate?Is the airflow rate setting low, such as “Indoor unit quiet” or “Airflow rate 1”? Increase the airflow rate setting.Is the set temperature appropriate?Is the adjustment of the airflow direction appropriate?
Air comes out.? Is there any furniture directly under or beside the indoor unit?Is the air conditioner in ECONO operation or OUTDOOR UNIT QUIET operation? ▶Page 18Are the air filters dirty?Is there anything blocking the air inlet or air outlet of the indoor unit or outdoor unit?Is a window or door open?Is an exhaust fan turning?

Mist comes out

Case Description / what to check
Mist comes out of the indoor unit.This happens when the air in the room is cooled into mist by the cold airflow during COOL or other operation.

Remote controller

Case Description / what to check
The unit does not receive signals from the remote controller or has a limited operating range.The batteries may be exhausted.Replace both batteries with new dry batteries AAA.LR03 (alkaline).For details, refer to “Preparation Before Operation”. ▶Page 9Signal communication may be disabled if an electronic-starter-type fluorescent lamp (such as inverter-type lamps) is in the room. Consult your dealer if that is the case.The remote controller may not function correctly if the transmitter is exposed to direct sunlight.
LCD is faint, is not working, or the display is erratic.The batteries may be exhausted.Replace both batteries with new dry batteries AAA.LR03 (alkaline).For details, refer to “Preparation Before Operation”. ▶Page 9
The LCD is blinking and the remote controller cannot be operated.Battery power has run out.Replace both batteries at the same time with new size AAA.LR03 (alkaline) batteries.Leaving exhausted batteries in the remote controller can result in injury due to battery leakage, rupturing or heating, or lead to equipment failure.(Even when the LCD is blinking, the OFF button remains functional.)
Other electric devices start operating.If the remote controller activates other electric devices, move them away or consult your dealer.

Air has an odour

Case Description / what to check
The air conditioner gives off an odour.The room odour absorbed in the unit is discharged with the airflow.We recommend you to have the indoor unit cleaned. Please consult your dealer.

Others

Case Description / what to check
The air conditioner suddenly starts behaving strangely during operation.? The air conditioner may malfunction due to lightning or radio.If the air conditioner malfunctions, turn off the power with the circuit breaker and restart the operation with the remote controller.
The ON/OFF TIMER does not operate according to the settings.? Check if the ON/OFF TIMER and the WEEKLY TIMER are set to the same time.Change or deactivate the settings in the WEEKLY TIMER. ▶Page 22

NOTE

Notes on the operating conditions

  • If operation continues under any conditions other than those listed in the table,
  • A safety device may activate to stop the operation.
  • Dew may form on the indoor unit and drip from it when COOL or DRY operation is selected.
Mode Operating conditions
COOL / DRYOutdoor temperature: -10.0~46.0°CIndoor temperature: 18.0~32.0°CIndoor humidity: 80% max.
HEATOutdoor temperature: -15.0~24.0°CIndoor temperature: 10.0~30.0°C

Troubleshooting

■ Call your dealer immediately

DAIKIN Cora FTKM20Q2VMA - ■ Call your dealer immediately - 1

WARNING

When an abnormality (such as a burning smell) occurs, stop operation and turn off the circuit breaker.

- Continued operation in an abnormal condition may result in problems, electric shock or fire.

- Consult the dealer where you bought the air conditioner.

Do not attempt to repair or modify the air conditioner by yourself.

  • Incorrect work may result in electric shock or fire.
  • Consult the dealer where you bought the air conditioner.

If one of the following symptoms takes place, call your dealer immediately.

  • The power cord is abnormally hot or damaged.
  • An abnormal sound is heard during operation.
  • The circuit breaker, a fuse, or the earth leakage circuit breaker cuts off the operation frequently.
  • A switch or a button often fails to work properly.
    • There is a burning smell.
    • Water leaks from the indoor unit.

Turn off the circuit breaker and call your dealer.

DAIKIN Cora FTKM20Q2VMA - WARNING - 1

■ After a power failure
- The air conditioner automatically resumes operation in about 3 minutes. Please wait for a while.
Lightning
- If there is a risk lightning could strike in the neighbourhood, stop operation and turn off the circuit breaker to protect the system.

■ Disposal requirements

- Dismantling of the unit, handling of the refrigerant, oil and other parts, should be done in accordance with the relevant local and national regulations.

DAIKIN Cora FTKM20Q2VMA - ■ Disposal requirements - 1

text_image 00 ON OFF 38:88 SAT SUN 8 ON 38:88 Cancel Timer

■ Fault diagnosis by remote controller

- In case the air conditioner is malfunctioning, you can check the error code via the remote controller before consulting with service personnel and informing them of the malfunction code.

  1. When Cancel is held down for about 5 seconds, "00" blinks in the temperature display section.

  2. Press Cancel repeatedly until a long beep is produced.

- The code indication changes as shown below, and notifies you with a long beep.

CODE MEANING
SYSTEM00 NORMAL
UA INDOOR-OUTDOOR UNIT COMBINATION FAULT
U0 REFRIGERANT SHORTAGE
U2 DROP VOLTAGE OR MAIN CIRCUIT OVERVOLTAGE
U4 FAILURE OF TRANSMISSION (BETWEEN INDOOR UNIT AND OUTDOOR UNIT)
INDOOR UNITA1 INDOOR PCB DEFECTIVENESS
A5 HIGH PRESSURE CONTROL OR FREEZE-UP PROTECTOR
A6 FAN MOTOR FAULT
C4 FAULTY HEAT EXCHANGER TEMPERATURE SENSOR
C9 FAULTY SUCTION AIR TEMPERATURE SENSOR
OUTDOOR UNITEACOOLING-HEATING SWITCHING ERROR
E1 CIRCUIT BOARD FAULT
E5 OL STARTED
E6 FAULTY COMPRESSOR START UP
E7 DC FAN MOTOR FAULT
E8 OVERCURRENT INPUT
F3 HIGH TEMPERATURE DISCHARGE PIPE CONTROL
F6 HIGH PRESSURE CONTROL (IN COOLING)
H0 SENSOR FAULT
H6 OPERATION HALT DUE TO FAULTY POSITION DETECTION SENSOR
H8 DC CURRENT SENSOR FAULT
H9 FAULTY SUCTION AIR TEMPERATURE SENSOR
J3FAULTY DISCHARGE PIPE TEMPERATURE SENSOR
J6FAULTY HEAT EXCHANGER TEMPERATURE SENSOR
L3 ELECTRICAL PARTS HEAT FAULT
L4 HIGH TEMPERATURE AT INVERTER CIRCUIT HEATSINK
L5 OUTPUT OVERCURRENT
P4 FAULTY INVERTER CIRCUIT HEATSINK TEMPERATURE SENSOR

NOTE

  • A short beep and 2 consecutive beeps indicates non-corresponding codes.
  • To cancel the code display, hold □ down for about 5 seconds. The code display also clears if no button is pressed for 1 minute.

MEMO

Quick Reference

DAIKIN Cora FTKM20Q2VMA - Quick Reference - 1

text_image ON 27.0°C MON 15:30 On/OffFAN Temp Mode Swing 10°C → 30°C 18°C ← 32°C 18°C ← 30°C

DAIKIN Cora FTKM20Q2VMA - Quick Reference - 2

flowchart
graph TD
    A["MODE"] --> B["A"]
    B --> C["Recovery to Air"]
    C --> D["Recovery to Air"]
    D --> E["Recovery to Air"]
    E --> F["Recovery to Air"]
    F --> G["Recovery to Air"]
    G --> H["Recovery to Air"]
    H --> I["Recovery to Air"]
    I --> J["Recovery to Air"]
    J --> K["Recovery to Air"]
    K --> L["Recovery to Air"]
    L --> M["Recovery to Air"]
    M --> N["Recovery to Air"]
    N --> O["Recovery to Air"]
    O --> P["Recovery to Air"]
    P --> Q["Recovery to Air"]
    Q --> R["Recovery to Air"]
    R --> S["Recovery to Air"]
    S --> T["Recovery to Air"]
    T --> U["Recovery to Air"]
    U --> V["Recovery to Air"]
    V --> W["Recovery to Air"]
    W --> X["Recovery to Air"]
    X --> Y["Recovery to Air"]
    Y --> Z["Recovery to Air"]
    Z --> AA["Recovery to Air"]
    AA --> AB["Recovery to Air"]
    AB --> AC["Recovery to Air"]
    AC --> AD["Recovery to Air"]
    AD --> AE["Recovery to Air"]
    AE --> AF["Recovery to Air"]
    AF --> AG["Recovery to Air"]
    AG --> AH["Recovery to Air"]
    AH --> AI["Recovery to Air"]
    AI --> AJ["Recovery to Air"]
    AJ --> AK["Recovery to Air"]
    AK --> AL["Recovery to Air"]
    AL --> AM["Recovery to Air"]
    AM --> AN["Recovery to Air"]
    AN --> AO["Recovery to Air"]
    AO --> AP["Recovery to Air"]
    AP --> AQ["Recovery to Air"]
    AQ --> AR["Recovery to Air"]
    AR --> AS["Recovery to Air"]
    AS --> AT["Recovery to Air"]
    AT --> AU["Recovery to Air"]
    AU --> AV["Recovery to Air"]
    AV --> AW["Recovery to Air"]
    AW --> AX["Recovery to Air"]
    AX --> AY["Recovery to Air"]
    AY --> AZ["Recovery to Air"]
    AZ --> BA["Recovery to Air"]
    BA --> BB["Recovery to Air"]
    BB --> BC["Recovery to Air"]
    BC --> BD["Recovery to Air"]
    BD --> BE["Recovery to Air"]
    BE --> BF["Recovery to Air"]
    BF --> BG["Recovery to Air"]
    BG --> BH["Recovery to Air"]
    BH --> BI["Recovery to Air"]
    BI --> BJ["Recovery to Air"]
    BJ --> BK["Recovery to Air"]
    BK --> BL["Recovery to Air"]
    BL --> BM["Recovery to Air"]
    BM --> BN["Recovery to Air"]
    BN --> BO["Recovery to Air"]
    BO --> BP["Recovery to Air"]
    BP --> BQ["Recovery to Air"]
    BQ --> BR["Recovery to Air"]
    BR --> BS["Recovery to Air"]
    BS --> BT["Recovery to Air"]
    BT --> BU["Recovery to Air"]
    BU --> BV["Recovery to Air"]
    BV --> BW["Recovery to Air"]
    BW --> BX["Recovery to Air"]
    BX --> BY["Recovery to Air"]
    BY --> BZ["Recovery to Air"]

DAIKIN INDUSTRIES, LTD.

Head office:

Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,

Kita-ku, Osaka, 530-8323 Japan

Tokyo office:

JR Shinagawa East Bldg., 2-18-1, Konan,

Minato-ku, Tokyo, 108-0075 Japan

https://www.daikin.com

DAIKIN Cora FTKM20Q2VMA - DAIKIN INDUSTRIES, LTD. - 1

The two-dimensional bar code is a manufacturing code.

OPERATION MANUAL

DAIKIN ROOM AIR CONDITIONER

DAIKIN Cora FTKM20Q2VMA - OPERATION MANUAL - 1

natural_image Line drawing of a single air conditioner unit (no text or symbols)

MODELS

FTXV50W2VMA
FTXV60W2VMA
FTXV71W2VMA

DAIKIN Cora FTKM20Q2VMA - MODELS - 1

natural_image Illustration of a city skyline above Earth with continents and oceans (no text or symbols)

Features

Enhanced comfort and energy savings

DAIKIN Cora FTKM20Q2VMA - Enhanced comfort and energy savings - 1

INTELLIGENT EYE

The INTELLIGENT EYE sensor detects human movement in a room. If no one is in the room for more than 20 minutes, the operation automatically changes to energy saving operation.

▶Page 15

DAIKIN Cora FTKM20Q2VMA - INTELLIGENT EYE - 1

WEEKLY TIMER

Up to 4 timer settings can be saved for each day of the week according to your family's life style. The WEEKLY TIMER allows you to set on/off times and the desired temperature. ▶Page 22

Other functions

DAIKIN Cora FTKM20Q2VMA - Other functions - 1

COMFORT AIRFLOW OUTDOOR UNIT QUIET

The airflow direction is upward while in COOL operation, and downward while in HEAT operation. This function prevents cold or warm air from blowing directly on your body. ▶Page 14

DAIKIN Cora FTKM20Q2VMA - COMFORT AIRFLOW OUTDOOR UNIT QUIET - 1

OUTDOOR UNIT QUIET operation assures a low noise level of the outdoor unit. This function is useful to maintain a quiet neighbourhood.

Page 18

DAIKIN Cora FTKM20Q2VMA - COMFORT AIRFLOW OUTDOOR UNIT QUIET - 2

natural_image Modern minimalist living room interior with white sofa, wall-mounted air conditioner unit, and potted tree (no text or symbols visible)

DAIKIN Cora FTKM20Q2VMA - COMFORT AIRFLOW OUTDOOR UNIT QUIET - 3

ECONO

This function enables efficient operation by limiting the maximum power consumption. It is useful when using the air conditioner and other electrical devices simultaneously on a shared electrical circuit. ▶Page 18

Contents

Read Before Operation

Safety Precautions 3

Names of Parts 5

Preparation Before Operation 9

Basic Operation

DAIKIN Cora FTKM20Q2VMA - Basic Operation - 1

AUTO · DRY · COOL · HEAT · FAN Operation ....11

DAIKIN Cora FTKM20Q2VMA - Basic Operation - 2

Adjusting the Airflow Rate .....12

DAIKIN Cora FTKM20Q2VMA - Basic Operation - 3

Adjusting the Airflow Direction .....13

Useful Functions

DAIKIN Cora FTKM20Q2VMA - Useful Functions - 1

COMFORT AIRFLOW Operation .....14

DAIKIN Cora FTKM20Q2VMA - Useful Functions - 2

INTELLIGENT EYE Operation .....15

DAIKIN Cora FTKM20Q2VMA - Useful Functions - 3

POWERFUL Operation ......17

DAIKIN Cora FTKM20Q2VMA - Useful Functions - 4

ECONO / OUTDOOR UNIT QUIET Operation ....18

TIMER Operation

DAIKIN Cora FTKM20Q2VMA - TIMER Operation - 1

ON/OFF TIMER Operation .....19

DAIKIN Cora FTKM20Q2VMA - TIMER Operation - 2

WEEKLY TIMER Operation ......22

Care

Care and Cleaning 28

When the Need Arises

FAQ 32

Troubleshooting 33

Safety Precautions

Read the precautions in this manual carefully before operating the unit.This appliance is filled with R32.
  • Keep this manual where the user can easily find it.
  • The precautions described herein are classified as WARNING and CAUTION. They both contain important information regarding safety. Be sure to observe all precautions without fail.
WARNINGFailure to follow these instructions properly may result in personal injury or loss of life.
CAUTIONFailure to observe these instructions properly may result in property damage or personal injury, which may be serious depending on the circumstances.
Never attempt.Be sure to follow the instructions.Be sure to establish an earth connection.

- After reading, keep this manual in a convenient place so that you can refer to it whenever necessary. If the equipment is transferred to a new user, be sure also to hand over the manual.

DAIKIN Cora FTKM20Q2VMA - Safety Precautions - 1

WARNING

DAIKIN Cora FTKM20Q2VMA - WARNING - 1

  • Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
  • The appliance must be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater).
  • Do not pierce or burn.
  • Be aware that refrigerants may not contain an odour.
  • The appliance must be installed, operated and stored in a room with floor area larger than 4.6m² for 50/60 class, 4.9m² for 71 class. Maintain an installation height of 1.8m or more from the floor surface to the bottom of the appliance. If the size of the room where the appliance is to be installed has less than the indicated minimum floor area, install it in a well ventilated room. For details refer to the WARNING list in the “Safety Precautions” section of the installation manual for the outdoor unit.
    • To avoid fire, explosion or injury, do not operate the unit when harmful gases (e.g. flammable or corrosive) are detected near the unit.
  • Be aware that prolonged, direct exposure to cool or warm air from the air conditioner, or to air that is too cool or too warm, can be harmful to your physical condition and health.
  • Do not place objects, including rods, your fingers, etc., in the air inlet or outlet. Product damage or personal injury may result due to contact with the air conditioner's high-speed fan blades.
  • Do not attempt to repair, dismantle, reinstall or modify the air conditioner yourself as this may result in water leakage, electric shock or fire hazards.
  • Do not use flammable spray near the air conditioner, or otherwise fire may result.
  • Do not use a refrigerant other than the one indicated on the outdoor unit (R32) when installing, moving or repairing. Using other refrigerants may cause trouble or damage to the unit, and personal injury.
  • To avoid electric shock, do not operate with wet hands.

DAIKIN Cora FTKM20Q2VMA - WARNING - 2

- Beware of fire in case of refrigerant leakage. If the air conditioner is not operating correctly, i.e. not generating cool or warm air, refrigerant leakage could be the cause. Consult your dealer for assistance. The refrigerant within the air conditioner is safe and normally does not leak.

However, in the event of a leakage, contact with a naked burner, heater or cooker may result in generation of noxious gas. Do not use the air conditioner until a qualified service person confirms that the leakage has been repaired.

  • Do not attempt to install or repair the air conditioner yourself. Improper workmanship may result in water leakage, electric shock or fire hazards. Please contact your local dealer or qualified personnel for installation and maintenance work.
  • If the air conditioner is malfunctioning (giving off a burning odour, etc.), turn off power to the unit and contact your local dealer. Continued operation under such circumstances may result in a failure, electric shock or fire hazards.
  • Be sure to install an earth leakage circuit breaker. Failure to install an earth leakage circuit breaker may result in electric shock or fire.

DAIKIN Cora FTKM20Q2VMA - WARNING - 3

- Be sure to earth the unit. Do not earth the unit to a utility pipe, lightning conductor or telephone earth lead. Imperfect earthing may result in electric shock.

DAIKIN Cora FTKM20Q2VMA - WARNING - 4

CAUTION

DAIKIN Cora FTKM20Q2VMA - CAUTION - 1

  • Do not use the air conditioner for purposes other than those for which it is intended. Do not use the air conditioner for cooling precision instruments, food, plants, animals or works of art as this may adversely affect the performance, quality and/or longevity of the object concerned.
  • Do not expose plants or animals directly to the airflow from the unit as this may cause adverse effects.
  • Do not place appliances that produce naked flames in places exposed to the airflow from the unit as this may impair combustion of the burner.
  • Do not block the air inlets nor outlets. Impaired airflow may result in insufficient performance or trouble.

DAIKIN Cora FTKM20Q2VMA - CAUTION - 2

  • Do not sit on the outdoor unit, put things on the unit, or pull the unit. Doing so may cause accidents, such as falling or toppling down, thus resulting in injury, product malfunctioning, or product damage.
  • Do not place objects that are susceptible to moisture directly beneath the indoor or outdoor units. Under certain conditions, condensation on the main unit or refrigerant pipes, air filter dirt or drain blockage may cause dripping, resulting in fouling or failure of the object concerned.
  • After prolonged use, check the unit stand and its mounts for damage. If they are left in a damaged condition, the unit may fall and cause injury.
  • To avoid injury, do not touch the air inlet or aluminium fins of the indoor or outdoor units.
  • The appliance is not intended for use by unattended young children or infirm persons. Impairment of bodily functions and harm to health may result.
  • Children should be supervised to ensure that they do not play with the unit or its remote controller. Accidental operation by a child may result in impairment of bodily functions and harm health.
  • Avoid impacts to the indoor and outdoor units, or otherwise product damage may result.
  • Do not place flammable items, such as spray cans, within 1m of the air outlet.

The spray cans may explode as a result of hot air from the indoor or outdoor units.

  • Be careful not to let pets urinate on the air conditioner. Urination on the air conditioner may result in electric shock or fire.
  • Do not wash the air conditioner with water, as this may result in electric shock or fire.
  • Do not place water containers (vases, etc.) above the unit, as this may result in electric shock or fire hazards if they should topple over.
  • Do not insert the batteries in the wrong polarity (+/-) orientation as this may result in short circuiting, fire, or battery leakage.
  • Do not sit or hang on the panel. The panel may fall, and injury or product malfunctioning may result.
  • Do not sway the panel. The panel may hit people or objects, and injury or property damage may result.
  • Do not let children play around the panel. Injury or property damage may result.
  • Do not pull the wires. The wires may be broken and the panel may fall, and injury or property damage may result.
  • Do not locate obstacles in the route. The panel may fall, and injury or property damage may result.
  • Do not bend or damage the wires. The wires may be broken and the panel may fall, and injury or property damage may result.
  • Do not put objects on the panel, or otherwise production malfunctioning may result.
  • Do not use an unstable stand at the time of operating or maintaining the air conditioner, or otherwise you may topple over or injury yourself.
  • Locate the remote controller in places out of reach of children. The wrong operation of the remote controller may result in injury.

DAIKIN Cora FTKM20Q2VMA - CAUTION - 3

  • To avoid oxygen depletion, ensure that the room is adequately ventilated if equipment such as a burner is used together with the air conditioner.
  • Before cleaning, be sure to stop unit operation and turn off the circuit breaker. Otherwise, an electric shock and injury may result.
  • Only connect the air conditioner to the specified power supply circuit. Power supplies other than the one specified may result in electric shock, overheating and fires.
  • Arrange the drain hose to ensure smooth drainage. Imperfect drainage may cause wetting of the building, furniture, etc.
  • Do not place objects in direct proximity of the outdoor unit and do not let leaves and other debris accumulate around the unit. Leaves are a hotbed for small animals which can enter the unit. Once inside the unit, such animals can cause malfunctions, smoke or fire if they come into contact with electrical parts.
  • Do not place objects around the indoor unit.
    Doing so may have an adverse influence on the performance, product quality, and life of the air conditioner.
  • This appliance is not intended to be used by persons with reduced physical, sensory or mental capabilities, or with lack of operation knowledge, unless they have been given supervision or instruction concerning the appliance use by person responsible for their safety. Keep out of children's reach to ensure that they do not play with the appliance.

Precautions relating to area surrounding the indoor and outdoor units

■ Be sure to follow the instructions below.

  • The indoor unit is at least 1m away from any television or radio set (unit may cause interference with the picture or sound).
  • Refrain from using the units in areas prone to high levels of oily smoke, such as a kitchen. Water leakage may result.

Names of Parts

Indoor Unit

DAIKIN Cora FTKM20Q2VMA - Indoor Unit - 1

text_image Front panel Air inlet Flaps (horizontal blades) Page 13 Air outlet Model name InTELLIGENT EYE sensor • Detects the movements of people and automatically switches between normal operation and energy saving operation. • The louvres are inside of the air outlet. Page 13 Room temperature sensor • Detects the air temperature around the unit. Page 15,16

Display

Signal receiver

  • Receives signals from the remote controller.
  • When the unit receives a signal, you will hear a beep sound.
Case Sound type
Operation start beep-beep
Setting changed beep
Operation stop long beep

DAIKIN Cora FTKM20Q2VMA - Signal receiver - 1

text_image OPERATION lamp (green) TIMER lamp (orange) ON/OFF Page 19,20,21,24,26 INTELLIGENT EYE lamp (green) Page 15

Indoor unit ON/OFF switch

  • Press this switch once to start operation. Press once again to stop it.
  • For the operation mode setting, refer to the following table.
Mode Temperature setting Airflow rate
AUTO 25.0°C AUTO

- This switch can be used when the remote controller is missing or out of batteries.

■ Open the front panel
DAIKIN Cora FTKM20Q2VMA - Indoor unit ON/OFF switch - 1

text_image Air filter Deodorizing filter (enzyme blue)

Outdoor Unit

DAIKIN Cora FTKM20Q2VMA - Indoor unit ON/OFF switch - 2

text_image Air inlet (back and side) Outdoor temperature sensor (back) Refrigerant pipes and inter-unit wire Earth terminal (inside) Drain hose Air outlet

Remote Controller

DAIKIN Cora FTKM20Q2VMA - Remote Controller - 1

text_image Signal transmitter Receiver To use the remote controller, aim the transmitter at the indoor unit. If there is anything blocking the signals between the unit and the remote controller, such as a curtain, the unit may not operate. The maximum transmission distance is about 7m. Display (LCD) Displays the current settings. (In this illustration, each section is shown with all its displays on for the purpose of explanation.) TEMPERATURE adjustment button Changes the temperature setting. ▶Page 11 FAN setting button Selects the airflow rate setting. ▶Page 12 POWERFUL button POWERFUL operation. ▶Page 17 ON/OFF button Press this button once to start operation. Press once again to stop it. ▶Page 11 Front cover Open the front cover. ▶Page 8 Model name ARC466A28

Names of Parts

■ Open the front cover

DAIKIN Cora FTKM20Q2VMA - ■ Open the front cover - 1

text_image MODE selector button • Selects the operation mode. (AUTO/DRY/COOL/HEAT/FAN) ▶ Page 11 ECONO/QUIET button • ECONO/OUTDOOR UNIT QUIET operation. ▶ Page 18 SENSOR button • INTELLIGENT EYE operation. ▶ Page 15 COMFORT button • COMFORT AIRFLOW operation. ▶ Page 14 OFF TIMER button (NIGHT SET mode) ▶ Page 20 TIMER CANCEL button • Cancels the timer setting. ▶ Page 19,20 • Cannot be used for the WEEKLY TIMER operation. SELECT button • Changes the clock, ON/OFF TIMER and WEEKLY TIMER settings.

Preparation Before Operation

DAIKIN Cora FTKM20Q2VMA - Preparation Before Operation - 1

CAUTION

Incorrect handling of batteries can result in injury from battery leakage, rupturing or heating, or lead to equipment failure.

Please observe the following precautions and use safely.

  • If the alkaline solution from the batteries should get in the eyes, do not rub the eyes. Instead, immediately flush the eyes with tap water and seek the attention of a medical professional.
  • Keep batteries out of reach of children. In the event that batteries are swallowed, seek the immediate attention of a medical professional.
  • Do not expose batteries to heat or fire. Do not disassemble or modify batteries. The insulation or gas release vent inside the battery may be damaged, resulting in battery leakage, rupturing, or heating.
  • Do not damage or peel off labels on the batteries.

■ To insert the batteries

  1. Slide the front cover to take it off.
  2. Insert 2 dry batteries AAA.LR03 (alkaline).
  3. Replace the front cover.

■ To fix the remote controller holder to a wall

  1. Choose a place from where the signals reach the unit.
  2. Fix the holder to a wall, a pillar, or similar location with the screws supplied with the holder.
  3. Place the remote controller in the remote controller holder.

■ To attach the deodorizing filter (enzyme blue)

  • If attaching the separately sold filters, attach them before turning the power on.

■ Turn on the circuit breaker

• After the power is turned on, the flaps of the indoor unit open and close once to set the reference position.

DAIKIN Cora FTKM20Q2VMA - ■ Turn on the circuit breaker - 1

text_image Position + and correctly!

DAIKIN Cora FTKM20Q2VMA - ■ Turn on the circuit breaker - 2

text_image Remote controller Screws Remote controller holder

NOTE

Notes on batteries

  • To avoid possible injury or damage from battery leakage or rupturing, remove the batteries when not using the product for long periods of time.
  • The standard replacement time is 1 year. Both batteries should be replaced at the same time. Be sure to replace them with new size AAA. LR03 (alkaline) batteries.
  • When battery power has run out, the LCD will begin blinking as an alert that the batteries need replacing. In some cases, when battery consumption is accelerated owing usage conditions, signal reception may decline before the LCD begins blinking.
  • The batteries supplied with the remote controller are for initial operation. The batteries may run out in less than 1 year.

Note on remote controller

- Do not drop the remote controller. Do not get it wet.

DAIKIN Cora FTKM20Q2VMA - Note on remote controller - 1

text_image MON 15:30 27.0°C Select Timer

■ To set the clock

1. Press

DAIKIN Cora FTKM20Q2VMA - Press - 1

"0.00 appears on the LCD.

"MON" and "💡 blink.

2. Press to set the current day of the week.

3. Press

DAIKIN Cora FTKM20Q2VMA - Press - 1

“ blinks.

4. Press Select to set the clock to the present time.

- Holding down ▲r rapidly increases or decreases the displayed time.

5. Press

- Point the remote controller at the indoor unit when pressing the buttons.

DAIKIN Cora FTKM20Q2VMA - Press - 1

“*”blinks.

NOTE

Note on setting the clock

- If the indoor unit's internal clock is not set to the correct time, the ON/OFF TIMER and WEEKLY TIMER will not operate punctually.

DAIKIN Cora FTKM20Q2VMA - Note on setting the clock - 1

text_image ON 27.0°C * A MON 15:30 On/Off Temp Mode Timer

The air conditioner operates with the operation mode of your choice.

From the next time on, the air conditioner will operate with the same operation mode.

■ To start

1. Press and select an operation mode.

• Each pressing of the button changes the mode setting in sequence.

DAIKIN Cora FTKM20Q2VMA - Press and select an operation mode. - 1

flowchart
graph LR
    A["Start"] --> B["Input"]
    B --> C["Process Step 1"]
    C --> D["Process Step 2"]
    D --> E["End"]

2. Press On/Off

• " Onpears on the LCD.
• The OPERATION lamp lights green.

DAIKIN Cora FTKM20Q2VMA - Press On/Off - 1
Display

■ To stop

Press again.

• “ ON appears from the LCD.
• The OPERATION lamp goes off.

■ To change the temperature setting

Press Temp

- Press ▲ to raise the temperature and press ▼ to lower the temperature.

Each pressing of the button changes the temperature by 0.5°C.

COOL operationHEAT operationAUTO operationDRY or FAN operation
18.0 - 32.0°C10.0 - 30.0°C18.0 - 30.0°CThe temperature setting cannot be changed.

NOTE

Notes on AUTO operation

  • In AUTO operation, the system selects an appropriate operation mode (COOL or HEAT) based on the indoor temperature, then starts the operation.
  • The system automatically reselects setting at a regular interval to bring the indoor temperature to user-setting level.

Note on COOL operation

  • This air conditioner cools the room by releasing the heat in the room outside.
    Therefore, the cooling performance of the air conditioner may be degraded if the outdoor temperature is high.

Note on DRY operation

- Eliminates humidity while maintaining the indoor temperature as much as possible. It automatically controls temperature and airflow rate, so manual adjustment of these functions is unavailable.

Notes on HEAT operation

  • Since this air conditioner heats the room by taking heat from outdoor air to indoors, the heating capacity becomes smaller in lower outdoor temperatures. If the heating effect is insufficient, it is recommended to use another heating appliance in combination with the air conditioner.
  • The heat pump system heats the room by circulating hot air around all parts of the room. After the start of HEAT operation, it takes some time before the room gets warmer.
  • In HEAT operation, frost may occur on the outdoor unit and lower the heating capacity. In that case, the system switches into defrosting operation to take away the frost.

Note on FAN operation

• This mode is valid for fan only.

DAIKIN Cora FTKM20Q2VMA - Note on FAN operation - 1

Adjusting the Airflow Rate

DAIKIN Cora FTKM20Q2VMA - Adjusting the Airflow Rate - 1

text_image 27.0°C MON 15:30 Fan

You can adjust the airflow rate to increase your comfort.

■ To adjust the airflow rate setting

DAIKIN Cora FTKM20Q2VMA - ■ To adjust the airflow rate setting - 1

• Each pressing of the button changes the airflow rate setting in sequence.

DAIKIN Cora FTKM20Q2VMA - ■ To adjust the airflow rate setting - 2

flowchart
graph LR
    A["AUTO Indoor unit quiet Airflow rate 1-5 (Low to High)"] --> B["..."]
    B --> C["..."]
    C --> D["..."]
    D --> E["..."]
    E --> F["..."]
  • When the airflow is set to “quiet operation starts and noise from the indoor unit will become quieter.
  • In the quiet operation mode, the airflow rate is set to a weak level.
  • In DRY operation, the airflow rate setting cannot be changed.
  • At smaller airflow rates, the cooling (heating) effect is also smaller.

Tips for saving energy

Keeping the temperature setting at a moderate level helps save energy.

- Recommended temperature setting for cooling: 26.0 - 28.0°C, heating: 20.0 - 24.0°C

Cover windows with a blind or a curtain.

- Blocking sunlight and air from outdoors increases the cooling (heating) effect.

Keep the air filters clean.

- Clogged air filters cause inefficient operation and waste energy. Clean them once in about every 2 weeks. ▶ Page 29

If you are not going to use the air conditioner for a long period, for example in spring or autumn, turn off the circuit breaker.

- The air conditioner always consumes a small amount of electricity even while it is not operating.

DAIKIN Cora FTKM20Q2VMA - Tips for saving energy - 1

Adjusting the Airflow Direction

DAIKIN Cora FTKM20Q2VMA - Adjusting the Airflow Direction - 1

text_image 27.0 MIN 15:30 Swing Timer

You can adjust the airflow direction to increase your comfort.

ATTENTION

• Always use a remote controller to adjust the angles of the flaps and louvres.

  • If you attempt to move the flaps and louvres forcibly by hand when they are swinging, the mechanism may be damaged.
  • Inside the air outlet, a fan is rotating at a high speed.

■ To start auto swing

Up and down airflow direction

Press

• “ Appears on the LCD.
• The flaps (horizontal blades) will begin to swing.

Right and left airflow direction

Press

• “ appears on the LCD.
- The louvres (vertical blades) will begin to swing.

The 3-D airflow direction

Press and .

• “ and ” appear on the LCD.
• The flaps and louvres move in turn.
- To cancel 3-D airflow, press either 📁 or again.

The flaps or louvres will stop moving.

DAIKIN Cora FTKM20Q2VMA - Press and . - 1

natural_image Diagram showing a device emitting a circular arrow, with no text or symbols present.

DAIKIN Cora FTKM20Q2VMA - Press and . - 2

natural_image Diagram showing airflow around a curved arrow, with no text or symbols present.

DAIKIN Cora FTKM20Q2VMA - Press and . - 3

natural_image Diagram showing curved arrows and a magnified inset of a device with a sensor icon (no text or symbols)

■ To set the flaps or louvres at the desired position

- This function is effective while the flaps or louvres are in auto swing mode.

Press and when the flaps or louvres reach the desired position.

• In the 3-D airflow, the flaps and louvres move in turn.
- “ 📋” or “ 📌 disappears from the LCD.

NOTE

Note on airflow direction setting

- The movable range of the flaps varies according to the operation mode.

Note on 3-D airflow

- Using 3-D airflow circulates cold air, which tends to collect at the bottom of the room, and hot air, which tends to collect near the ceiling, throughout the room, preventing areas of cold and hot developing.

Movable range of the flaps
DAIKIN Cora FTKM20Q2VMA - Note on 3-D airflow - 1

text_image of the flaps COOL / DRY FAN HEAT

DAIKIN Cora FTKM20Q2VMA - Note on 3-D airflow - 2

COMFORT AIRFLOW Operation

DAIKIN Cora FTKM20Q2VMA - COMFORT AIRFLOW Operation - 1

text_image 27.0°C MON 15:30 Comfort Timer

The flow of air will be in the upward direction while in COOL operation and in the downward direction while in HEAT operation, which will provide a comfortable wind that will not come in direct contact with people.

DAIKIN Cora FTKM20Q2VMA - COMFORT AIRFLOW Operation - 2

natural_image Diagram of a wall-mounted air conditioner unit with airflow direction indicated (no text or symbols)

COOL operation

DAIKIN Cora FTKM20Q2VMA - COMFORT AIRFLOW Operation - 3

natural_image Pure diagram of a curved pipe or duct with a rectangular component, no text or symbols present

HEAT operation

■ To start

DAIKIN Cora FTKM20Q2VMA - ■ To start - 1

Press

Comfort

DAIKIN Cora FTKM20Q2VMA - ■ To start - 2

DAIKIN Cora FTKM20Q2VMA - ■ To start - 3

appears on the LCD.

COOL and DRY operation HEAT operation FAN operation
Flaps directionGoes up Goes downNot available
Airflow rate AUTO

■ To cancel

DAIKIN Cora FTKM20Q2VMA - ■ To cancel - 1

Press

Comfort

DAIKIN Cora FTKM20Q2VMA - ■ To cancel - 2

again.

• “ disappears from the LCD.
- The flaps will return to the position in memory form before COMFORT AIRFLOW operation.

NOTE

Notes on COMFORT AIRFLOW Operation

  • The flaps position will change, preventing air from blowing directly on the occupants of the room.
  • POWERFUL operation and COMFORT AIRFLOW operation cannot be used at the same time.
    • The airflow rate will be set to AUTO.
  • If the upward and downward airflow direction is selected, the COMFORT AIRFLOW function will be canceled.
    Priority is given to the function of whichever button is pressed last.

DAIKIN Cora FTKM20Q2VMA - Notes on COMFORT AIRFLOW Operation - 1

INTELLIGENT EYE Operation

DAIKIN Cora FTKM20Q2VMA - INTELLIGENT EYE Operation - 1

text_image 27.0°C MON 15:30 Sensor Timer

The INTELLIGENT EYE operation detects human movement. If no one is detected in the room for more than 20 minutes, the unit automatically enters energy saving operation.

DAIKIN Cora FTKM20Q2VMA - INTELLIGENT EYE Operation - 2

CAUTION

  • Do not place large objects near the INTELLIGENT EYE sensor. Also keep heating units and humidifiers outside the sensor's detection area. This sensor can detect undesirable objects.
  • Do not hit or violently push the INTELLIGENT EYE sensor. This can lead to damage and malfunction.

DAIKIN Cora FTKM20Q2VMA - CAUTION - 1

To start

DAIKIN Cora FTKM20Q2VMA - To start - 1

Press Sensor and select the desired model.

• Each time the button is pressed, a different setting option is displayed on the LCD.
• The INTELLIGENT EYE lamp lights green.

DAIKIN Cora FTKM20Q2VMA - Press Sensor and select the desired model. - 1

DAIKIN Cora FTKM20Q2VMA - Press Sensor and select the desired model. - 2

flowchart
graph LR
    A["User Icon"] -->|Display| B["blank"]
    B --> C["No Setting Intelligent eye"]

• The lamp lights when human movement is detected.

DAIKIN Cora FTKM20Q2VMA - Press Sensor and select the desired model. - 3

To cancel

DAIKIN Cora FTKM20Q2VMA - To cancel - 1

Press

DAIKIN Cora FTKM20Q2VMA - Press - 1

button.

• The INTELLIGENT EYE lamp goes off.

INTELLIGENT EYE operation is useful for energy saving

■ People are detected in the sensing area.
DAIKIN Cora FTKM20Q2VMA - INTELLIGENT EYE operation is useful for energy saving - 1

natural_image Illustration of an elderly person sitting on a sofa with a TV displaying a downward arrow (no text or symbols)

The air conditioner is in normal operation while the sensor is detecting human movement.

■ No people are detected in the sensing area.
DAIKIN Cora FTKM20Q2VMA - INTELLIGENT EYE operation is useful for energy saving - 2

natural_image Diagram showing a car with a downward arrow and a sofa, no text or symbols present

The air conditioner will switch to energy-saving mode after 20 minutes.

Energy saving operation

  • If no presence detected in the room for 20 minutes, the energy saving operation will start, and the INTELLIGENT EYE lamp goes off. If human movement is detected again, the INTELLIGENT EYE lamp lights up and energy saving operation terminates.
  • This operation changes the temperature by -2^ in HEAT / +2^ in COOL / +2^ in DRY operation from the set temperature.
    When the room temperature exceeds 30^ C, the operation changes the temperature by +1^ C in COOL / +1^ C in DRY operation from the set temperature.
  • This operation decreases the airflow rate slightly in FAN operation only.

NOTE

Notes on INTELLIGENT EYE operation

- Application range is as follows.

DAIKIN Cora FTKM20Q2VMA - Notes on INTELLIGENT EYE operation - 1

text_image Vertical angle 90° (Side view) 7m 90°

DAIKIN Cora FTKM20Q2VMA - Notes on INTELLIGENT EYE operation - 2

text_image Horizontal angle 110° (Top view) 55° 55° 7m
  • The sensor may not detect moving objects further than 7m away. (Please see the application range)
  • Sensor detection sensitivity changes according to the indoor unit location, the speed of passers-by, temperature range, etc.
  • The sensor could also mistakenly detect pets, sunlight, fluttering curtains and light reflected off of mirrors as passers-by.
  • NIGHT SET mode ▶Page 20 will not switch on during use of INTELLIGENT EYE operation.

Note on combination of COMFORT AIRFLOW operation and INTELLIGENT EYE operation

- The airflow rate will be set to AUTO. If the up and down airflow direction is selected, COMFORT AIRFLOW operation will be cancelled. Priority is given to the function of whichever button is pressed last.

DAIKIN Cora FTKM20Q2VMA - Note on combination of COMFORT AIRFLOW operation and INTELLIGENT EYE operation - 1

POWERFUL Operation

DAIKIN Cora FTKM20Q2VMA - POWERFUL Operation - 1

text_image MON 15:30 Powerful

POWERFUL operation quickly maximises the cooling (heating) effect in any operation mode. In this mode, the air conditioner operates at maximum capacity.

■ To start

Press during operation.

• “ appears on the LCD.
- POWERFUL operation ends in 20 minutes. Then the system automatically operates again with the previous settings which were used before POWERFUL operation.

■ To cancel

Press again.

• “ disappears from the LCD.

NOTE

Notes on POWERFUL operation

  • Pressing causes the settings to be cancelled, and " " disappears from the LCD.
  • POWERFUL operation will not increase the capacity of the air conditioner if the air conditioner is already in operation with its maximum capacity demonstrated.
  • In COOL, HEAT and AUTO operation
    To maximise the cooling (heating) effect, the capacity of outdoor unit increases and the airflow rate becomes fixed at the maximum setting. The temperature and airflow settings cannot be changed.
  • In DRY operation
    The temperature setting is lowered by 2.5^ C and the airflow rate is slightly increased.
  • In FAN operation
    The airflow rate is fixed at the maximum setting.

Regarding the combination of POWERFUL and other operations

POWERFUL + COMFORT AIRFLOWNot available*
POWERFUL + ECONO
POWERFUL + OUTDOOR UNIT QUIET

*Priority is given to the function of whichever button is pressed last.

DAIKIN Cora FTKM20Q2VMA - Notes on POWERFUL operation - 1

ECONO / OUTDOOR UNIT QUIET Operation

DAIKIN Cora FTKM20Q2VMA - ECONO / OUTDOOR UNIT QUIET Operation - 1

text_image 27.0 MON 15:30 Erona Quiet Tieter

ECONO operation enables efficient operation by limiting the maximum power consumption. This function is useful to prevent the circuit breaker from tripping when the unit operates alongside other appliances on the same circuit.

OUTDOOR UNIT QUIET operation lowers the noise level of the outdoor unit by changing the frequency and fan speed of the outdoor unit. This function is convenient during the night-time operation.

■ To start

Press Econo/Quiet and select the desired mode.

• Each time the button is pressed, a different setting option appears on the LCD.

DAIKIN Cora FTKM20Q2VMA - Press Econo/Quiet and select the desired mode. - 1

flowchart
graph LR
    A["ECONO OUTDOOR UNIT QUIET"] --> B["Combination"]
    B --> C["blank\nNo Setting"]

■ To cancel

Press 📄 unil no icon is displayed.

NOTE

Notes on ECONO operation

  • This operation is performed with lower power and therefore may not provide a sufficient cooling (heating) effect.
  • Pressing ⏻ causes the settings to be cancelled, and “” disappears from the LCD.
  • If the power consumption level is already low, switching to ECONO operation will not reduce the power consumption.

Notes on OUTDOOR UNIT QUIET operation

  • Even if the operation is stopped by using the remote controller or the indoor unit ON/OFF switch when using OUTDOOR UNIT QUIET operation, "💡" will remain displayed on the remote controller.
  • OUTDOOR UNIT QUIET operation will not reduce the frequency nor fan speed if they already are operating at reduced levels.
  • This operation is performed with lower power and therefore may not provide a sufficient cooling (heating) effect.

Possible combinations of ECONO / OUTDOOR UNIT QUIET operation and basic operations

Operation mode
DRY COOL HEAT FAN
ECONO-
OUTDOOR UNIT QUIET--

DAIKIN Cora FTKM20Q2VMA - Notes on OUTDOOR UNIT QUIET operation - 1

ON/OFF TIMER Operation

DAIKIN Cora FTKM20Q2VMA - ON/OFF TIMER Operation - 1

text_image ON 27.0°C A 6:00 Select On Cancel Timer

Timer functions are useful for automatically switching the air conditioner on or off at night or in the morning. You can also use the ON TIMER and OFF TIMER together.

[ON TIMER with a 24 hour clock display] (24 HOUR ON/OFF TIMER)

■ To set

- Check that the clock is correct. If not, set the clock to the present time. ▶Page 10

1. Press On

DAIKIN Cora FTKM20Q2VMA - Press On - 1

"5.00 appears on the LCD. "ON" blinks.

- “④” and day of the week disappear from the LCD.

2. Press until the time setting reaches the point you like.

• Each pressing of either button increases or decreases the time setting by 10 minutes. Holding down either button changes the setting rapidly.

3. Press on again.

- “ON” and setting time appear on the LCD. - The TIMER lamp lights orange.

DAIKIN Cora FTKM20Q2VMA - Press on again. - 1
Display

■ To cancel

Press Cancel.

  • “ON” and setting time disappear from the LCD.
  • “ ⏻ ” and day of the week appear on the LCD.
    • The TIMER lamp goes off.

NOTE

Note on TIMER operation

- When TIMER is set, the present time is not displayed.

In the following cases, set the timer again.

• After the circuit breaker has turned off.
• After a power failure.
• After replacing the batteries in the remote controller.

DAIKIN Cora FTKM20Q2VMA - In the following cases, set the timer again. - 1

text_image 27.0 OFF 0:00 Off Select Cancel Timer

[OFF TIMER with a 24 hour clock display] (24 HOUR ON/OFF TIMER)

■ To set

- Check that the clock is correct. If not, set the clock to the present time. ▶Page 10

1. Press Off

DAIKIN Cora FTKM20Q2VMA - Press Off - 1

"0:appears on the LCD. "OFF" blinks.

- “ ⊕” and day of the week disappear from the LCD.

2. Press until the time setting reaches the point you like.

• Each pressing of either button increases or decreases the time setting by 10 minutes. Holding down either button changes the time setting rapidly.

3. Press again.

- "OF and setting time appear on the LCD. - The TIMER lamp lights orange.

DAIKIN Cora FTKM20Q2VMA - Press again. - 1

text_image Display

■ To cancel

Press Cancel.

  • “OF and setting time disappear from the LCD.
  • “ ⏻” and day of the week appear on the LCD.
    • The TIMER lamp goes off.

[ON/OFF TIMER combination]

■ To combine

- A sample setting for combining the 2 timers is shown below.

DAIKIN Cora FTKM20Q2VMA - ■ To combine - 1

text_image (Example) Present time: 23:00 (The unit is operating) OFF TIMER at 0:00 ON TIMER at 14:00) Combined OFF 0:00 ON 14:00

NOTE

NIGHT SET mode

- When the OFF TIMER is set, the air conditioner automatically adjusts the temperature setting (0.5°C up in COOL, 2.0°C down in HEAT) to prevent excessive cooling (heating) during sleeping hours.

DAIKIN Cora FTKM20Q2VMA - NIGHT SET mode - 1

ON/OFF TIMER Operation

DAIKIN Cora FTKM20Q2VMA - ON/OFF TIMER Operation - 1

text_image 27.0°C ON Ihr Off Select On Cancel Timer

[ON/OFF TIMER with an hours remaining display] (COUNT UP-DOWN ON/OFF TIMER)

- Check that the clock is correct. If not, set the clock to the present time. ▶Page 10

DAIKIN Cora FTKM20Q2VMA - Press and hold on or for about 5 seconds, when signal indicator (▲) blink, release your finger from the button. - 1

For ON TIMER

"Ibr" appears on the LCD.

"ON" blinks.

For OFF TIMER

"Ihr" appears on the LCD

"OFF" blinks.

- “ ⏻ ” and day of the week disappear from the LCD.

2. Press until the time setting reaches the point you like.

• Each pressing of the button increases or decreases the time setting by 1 hour.

• The time can be set between 1 and 12 hours.

3. Press on or again.

  • “ONand” “OFF and setting time appear on the LCD.
    • The TIMER lamp lights orange.
  • To change the display mode from COUNT UP-DOWN ON/OFF TIMER to 24 HOUR ON/OFF TIMER, repeat STEP 1, and continue from STEP 2 of "24 HOUR ON/OFF TIMER".

▶ Page 19, 20

- Timer display mode cannot be changed while "ON" or "OFF" are blinking. Press On or to stop the blinking.

DAIKIN Cora FTKM20Q2VMA - Press on or again. - 1
Display

■ Combining display modes

- Different display modes (24 HOUR ON/OFF TIMER and COUNT UP-DOWN ON/OFF TIMER) can be used for the ON TIMER and OFF TIMER simultaneously.

DAIKIN Cora FTKM20Q2VMA - ■ Combining display modes - 1

text_image (Example) Present time: 22:00 [The unit is operating] OFF TIMER at 1:00 (3 hours after present time) ) Combined ON TIMER at 6:00 (8 hours after present time) OFF 3hr ON 6:00 OFF 1:00 ON 8hr OFF 3hr ON 8hr

NOTE

Note on COUNT UP-DOWN ON/OFF TIMER

- After setting, the time displayed on the LCD will automatically count down by 1 hour for every 1 hour that passes. For example, if the OFF TIMER is set to 3 hours, the display will change as follows: 3hr 2hr 1hr blank (OFF)

Switching between ON/OFF TIMER display modes (24 hour clock and hours remaining display)

- When changing timer display modes (from 24 HOUR ON/OFF TIMER to COUNT UP-DOWN ON/OFF TIMER or vice versa), the timer cancels. The timer must be set again to activate it.

WEEKLY TIMER Operation

Up to 4 timer settings can be saved for each day of the week. This is convenient to adapt the WEEKLY TIMER to your family's life style.

■ Setting example of the WEEKLY TIMER

The same timer settings are used from Monday through Friday, while different timer settings are used for the weekend.

[Monday]Make timer settings for programmes 1-4. ▶Page 23
Programme 1Programme 2Programme 3Programme 4
DAIKIN Cora FTKM20Q2VMA - ■ Setting example of the WEEKLY TIMER - 1DAIKIN Cora FTKM20Q2VMA - ■ Setting example of the WEEKLY TIMER - 2DAIKIN Cora FTKM20Q2VMA - ■ Setting example of the WEEKLY TIMER - 3DAIKIN Cora FTKM20Q2VMA - ■ Setting example of the WEEKLY TIMER - 4
[Tuesday] to [Friday]Use the copy mode to make settings for Tuesday to Friday, because these settings are the same as those for Monday. ▶Page 25Pr DAIKIN Cora FTKM20Q2VMA - ■ Setting example of the WEEKLY TIMER - 5
[Saturday]No timer settings
[Sunday]Make timer settings for programmes 1-4. ▶Page 23DAIKIN Cora FTKM20Q2VMA - ■ Setting example of the WEEKLY TIMER - 6
  • Up to 4 reservations per day and 28 reservations per week can be set using the WEEKLY TIMER. The effective use of the copy mode simplifies timer programming.
  • The use of ON-ON-ON-ON settings, for example, makes it possible to schedule operating mode and set temperature changes. Furthermore, by using OFF-OFF-OFF-OFF settings, only the turn off time of each day can be set. This will turn off the air conditioner automatically if you forget to turn it off.

DAIKIN Cora FTKM20Q2VMA - ■ Setting example of the WEEKLY TIMER - 7

WEEKLY TIMER Operation

DAIKIN Cora FTKM20Q2VMA - WEEKLY TIMER Operation - 1

text_image 27.0°C ON 6:00 25.0°C MON Select Next Timer

■ To use WEEKLY TIMER operation

Setting mode

• Make sure the day of the week and time are set. If not, set the day of the week and time. ▶ Page 10

Programme 1 Programme 2 Programme 3 Programme 4
DAIKIN Cora FTKM20Q2VMA - Setting mode - 1

text_image [Monday] ON OFF 25.0°C 27.0°C 6:00 8:30 17:30 22:00 ON OFF

Setting Displays
DAIKIN Cora FTKM20Q2VMA - Setting mode - 2

text_image MON Day and number ON/OFF ON WEEKLY ON Time WEEKLY ON 6:00 Temperature WEEKLY ON 25.0°C

1. Press

• The day of the week and the reservation number of the current day will be displayed.
- 1 to 4 settings can be made per day.

2. Press Select to select the desired day of the week and reservation number.

- Pressing Select changes the reservation number and the day of the week.

3. Press Next .

• The day of the week and reservation number will be set.
• “ Ⓧ WEEKLY ” and “ ON ” blink.

4. Press Select to select the desired mode.

- Pressing Select changes the "ON" or "OFF" setting in sequence.

DAIKIN Cora FTKM20Q2VMA - Press Select to select the desired mode. - 1

flowchart
graph LR
    A["ON"] --> B["OFF"]
    B --> C["blank"]
    D["ON TIMER"] --> A
    E["OFF TIMER"] --> B
    F["No Setting"] --> C

Pressing Select puts the sequence in reverse.

  • In case the reservation has already been set, selecting "blank" deletes the reservation.
  • Proceed to STEP 9 if "blank" is selected.
  • To return to the day of the week and reservation number setting, press 📄.

5. Press Next .

  • The ON/OFF TIMER mode will be set.
    • “WEEKLY” and the time blink.

DAIKIN Cora FTKM20Q2VMA - Press Next . - 1

text_image 27.0°C ON 6:00 TUE 25.0°C Select Next Timer

6. Press to select the desired time.

  • The time can be set between 0:00 and 23:50 in 10-minute intervals.
  • To return to the ON/OFF TIMER mode setting, press Back
  • Proceed to STEP 9 when setting the OFF TIMER.

7. Press Next

• The time will be set.
• “WEEKLY” and the temperature blink.

8. Press to select the desired temperature.

• The temperature can be set between 10.0^ C and 32.0^ C.
COOL or AUTO: The unit operates at 18.0°C even if it is set to 10.0°C to 17.0°C. ▶Page 11 HEAT or AUTO : The unit operates at 30.0°C even if it is set to 31.0°C to 32.0°C. ▶Page 11
• To return to the time setting, press Back
- The set temperature is only displayed when the mode setting is on.

9. Press Next

  • The temperature will be set and go to the next reservation setting.
  • The temperature is set while in ON TIMER operation, and the time is set while in OFF TIMER operation.
    • The next reservation screen will appear.
    • To continue further settings, repeat the procedure from STEP 4.

10. Press to complete the setting.

  • Be sure to direct the remote controller toward the indoor unit and check for a receiving tone and blinking of the OPERATION lamp.
  • “WEEKLY” appears on the LCD and WEEKLY TIMER operation is activated.
    • The TIMER lamp lights orange.

DAIKIN Cora FTKM20Q2VMA - Press to complete the setting. - 1
Display

- A reservation made once can be easily copied and the same settings used for another day of the week. Refer to Copy mode. ▶Page 25

NOTE

Notes on WEEKLY TIMER operation

  • Do not forget to set the clock on the remote controller first. ▶Page 10
  • The day of the week, ON/OFF TIMER mode, time and set temperature (only for ON TIMER mode) can be set with the WEEKLY TIMER. Other settings for the ON TIMER are based on the settings just before the operation.
  • WEEKLY TIMER and ON/OFF TIMER operation cannot be used at the same time. The ON/OFF TIMER operation has priority if it is set while WEEKLY TIMER is still active. The WEEKLY TIMER will enter the standby state, and “WEEKLY” will disappear from the LCD. When the ON/OFF TIMER is up, the WEEKLY TIMER will automatically become active.
  • Only the time and set temperature with the WEEKLY TIMER are sent with the ☐. Set the WEEKLY TIMER only after setting the operation mode, the airflow rate and the airflow direction ahead of time.
  • Turning off the circuit breaker, power failure, and other similar events will render operation of the indoor unit's internal clock inaccurate. Reset the clock. ▶Page 10
  • can be used only for the time and temperature settings. It cannot be used to go back to the reservation number.

DAIKIN Cora FTKM20Q2VMA - Notes on WEEKLY TIMER operation - 1

WEEKLY TIMER Operation

DAIKIN Cora FTKM20Q2VMA - WEEKLY TIMER Operation - 1

text_image 27.8°C ON 6:00 TUE 25.0°C Copy Select Timer

Copy mode

- A reservation made once can be copied to another day of the week. The whole reservation of the selected day of the week will be copied.

Programme 1 Programme 2 Programme 3 Programme 4
DAIKIN Cora FTKM20Q2VMA - Copy mode - 1

text_image [Monday] ON OFF ON OFF 25.0°C 27.0°C 6:00 8:30 17:30 22:00 COPY

Programme 1 Programme 2 Programme 3 Programme 4
DAIKIN Cora FTKM20Q2VMA - Copy mode - 2

text_image [Tuesday] to [Friday] ON OFF ON OFF 25.0°C 27.0°C 6:00 8:30 17:30 22:00

Setting Displays
DAIKIN Cora FTKM20Q2VMA - Copy mode - 3

text_image 27.0°C ON 6:00 MON 25.0°C Confirmation Copy Paste CP ON 6:00 TUE Normal CP ON 6:00 TUE 25.0°C ON 15:30 27.0°C ON 15:30
  1. Press

  2. Press Select to confirm the day of the week to be copied.

  3. Press Copy .

- The whole reservation of the selected day of the week will be copied.

  1. Press Select to select the destination day of the week.

  2. Press Copy

- The reservation will be copied to the selected day of the week. The whole reservation of the selected day of the week will be copied.

• To continue copying the settings to other days of the week, repeat STEP 4 and STEP 5.

  1. Press ☐ to complete the setting.

- “ WEEKLY ” appears on the LCD and WEEKLY TIMER operation is activated.

NOTE

Note on COPY MODE

- The entire reservation of the source day of the week is copied in the copy mode. In the case of making a reservation change for any day of the week individually after copying the content of weekly reservations, press ____ and change the settings in the steps of Setting mode ▶Page 23

DAIKIN Cora FTKM20Q2VMA - Note on COPY MODE - 1

text_image 27.0 ON 6:00 TUE 25.0°C Weekly Select Next Time

■ Confirming a reservation

• The reservation can be confirmed.

DAIKIN Cora FTKM20Q2VMA - ■ Confirming a reservation - 1

text_image Setting Displays TUE 15:30 Normal Confirmation TUE ON 6:00 25.0°C

1. Press

- The day of the week and the reservation number of the current day will be displayed.

2. Press to select the day of the week and the reservation number to be confirmed.

  • Pressing displays the reservation details.
  • To change the confirmed reserved settings, select the reservation number and press. The mode is switched to setting mode. Proceed to Setting mode STEP 4. ▶Page 23

3. Press to exit the confirmation mode.

  • “ WEEKLYrs on the LCD and WEEKLY TIMER operation is activated.
    • The TIMER lamp lights orange.

DAIKIN Cora FTKM20Q2VMA - Press to exit the confirmation mode. - 1
Display

■ To deactivate WEEKLY TIMER operation

Press ☐ while “ Ⓧ WEEKLY ” is displayed on the LCD.

• “WEI bears from the LCD.
• The TIMER lamp goes off.
• To reactivate the WEEKLY TIMER operation, press ____ again.
- If a reservation deactivated with weekly is activated once again, the last reservation mode will be used.

NOTE

- If not all the reservation settings are reflected, deactivate the WEEKLY TIMER operation once. Then press ____ again to reactivate the WEEKLY TIMER operation.

DAIKIN Cora FTKM20Q2VMA - NOTE - 1

WEEKLY TIMER Operation

DAIKIN Cora FTKM20Q2VMA - WEEKLY TIMER Operation - 1

text_image 27.0°C ON 6:00 TUE 25.0°C Weekly Select Next Timer

■ To delete a reservation

An individual reservation

1. Press

- The day of the week and the reservation number will be displayed.

2. Press to select the day of the week and the reservation number to be deleted.

3. Press Next

- “ WEEKLY ” or “ Oblink. OFF

4. Press until no icon is displayed.

- Pressing changes the ON/OFF TIMER mode in sequence.

- Selecting "blank" will cancel any reservation you may have.

DAIKIN Cora FTKM20Q2VMA - Press until no icon is displayed. - 1

flowchart
graph LR
    A["ON"] --> B["OFF"]
    B --> C["blank"]
    D["ON TIMER OFF TIMER"] --> E["No Setting"]

Pressing Select puts the sequence in reverse.

5. Press Next .

- The selected reservation will be deleted.

6. Press

- If there are still other reservations, WEEKLY TIMER operation will be activated.

Reservations for each day of the week

- This function can be used for deleting reservations for each day of the week.

- It can be used while confirming or setting reservations.

1. Press

- The day of the week and the reservation number will be displayed.

2. Press Select to select the day of the week to be deleted.

3. Hold for about 5 seconds.

- The reservation of the selected day of the week will be deleted.

4. Press

- If there are still other reservations, WEEKLY TIMER operation will be activated.

All reservations

Hold Weekly for about 5 seconds with the normal display.

  • Be sure to direct the remote controller toward the indoor unit and check for a receiving tone.
  • This operation cannot be used for the WEEKLY TIMER setting display.
  • All reservations will be deleted.

Care and Cleaning

DAIKIN Cora FTKM20Q2VMA - Care and Cleaning - 1

CAUTION

  • Before cleaning, be sure to stop the operation and turn off the circuit breaker.
  • Do not touch the aluminum fins of the indoor unit. If you touch those parts, this may cause an injury.

DAIKIN Cora FTKM20Q2VMA - CAUTION - 1

text_image Quick reference Cleaning parts Front panel • Wipe it with a soft damp cloth. • Only neutral detergent may be used. If dirty Air filter • Vacuum dust or wash the filter. Once every 2 weeks ▶Page 29 Deodorizing filter (enzyme blue) To purchase the filters (Table 1) or to purchase the another type, contact the dealer where you bought the air conditioner.

To purchase the filters (Table 1) or to purchase the another type, contact the dealer where you bought the air conditioner. The method of cleaning and replacement of the filters may differ depending on the model. Refer to the label attached to the separately sold filters themselves.

Table 1

Item Part No.
Air quality filter (enzyme blue with PM2.5) - without frame (set of 2)BAFP094A43
Deodorizing filter (enzyme blue) - without frame (set of 2) BAFP094A41
Dust collection filter (PM 2.5) - without frame (set of 2) BAFP046A41
Titanium apatite deodorizing filter - without frame (set of 2) KAF970A46

Indoor unit and remote controller

- Wipe them with a soft cloth.

If dirty

Deodorizing filter (enzyme blue), Titanium apatite deodorizing filter.

• Vacuum dust or replace the filter. [Cleaning] [Replacement]

Once every 6 months Once every 3 years

Page 30

▶Page 30

Air quality filter (enzyme blue with PM2.5), Dust collection filter (PM 2.5)

- No cleaning is required. Please replace the filter every 6 months. ▶Page 30

NOTE

For cleaning, do not use any of the following:

• Water hotter than 40°C
• Volatile liquid such as benzene, petrol and thinner
- Polishing compounds
- Rough materials such as a scrubbing brush

DAIKIN Cora FTKM20Q2VMA - NOTE - 1

natural_image Illustration of a kettle, a tray of food, and a bottle (no text or symbols)

Care and Cleaning

Air filter

1. Open the front panel.

- Hold the front panel by the sides and open it.

DAIKIN Cora FTKM20Q2VMA - Open the front panel. - 1

natural_image Diagram of an air conditioner unit showing airflow direction and component layout (no text or symbols)

2. Pull out the air filters.

- Push the filter tab at the centre of each air filter a little upwards, then pull it down.

DAIKIN Cora FTKM20Q2VMA - Pull out the air filters. - 1

text_image 1) Push 2) Pull down

3. Wash the air filters with water or clean them with vacuum cleaner.

- It is recommended to clean the air filters every 2 weeks.

DAIKIN Cora FTKM20Q2VMA - Wash the air filters with water or clean them with vacuum cleaner. - 1

natural_image Illustration of hands holding a grid-based device with a tool, no text or symbols visible

If the dust does not come off easily

  • Wash the air filters with neutral detergent thinned with lukewarm water, then dry them up in the shade.
  • Be sure to remove the filter (small). Refer to "Filter (small)" on the next page.

DAIKIN Cora FTKM20Q2VMA - If the dust does not come off easily - 1

natural_image Simple line drawing of a basin with a rectangular plate on top (no text or symbols)

4. Reattach the filters.

5. Close the front panel slowly.

- Press the panel at both sides and the centre.

DAIKIN Cora FTKM20Q2VMA - Close the front panel slowly. - 1

natural_image Illustration of a car air conditioner with airflow arrows indicating airflow direction (no text or symbols)

- Make sure that the front panel is securely fixed.

■ Filter (small)

* For the applicable filter type, please refer to ▶Page 28.

Attaching

  1. Open the front panel and pull out the air filters. ▶Page 29

  2. Insert the filter.

- Check that the filters are inserted securely under the tabs.

DAIKIN Cora FTKM20Q2VMA - Attaching - 1

text_image Claw Filter (small)

Cleaning and Replacement

  1. Open the front panel and pull out the air filters. ▶Page 29

  2. Take off the filter.

  3. Hold the recessed parts of the frame and unhook the 4 claws.

  4. Remove the filters from the tabs.

DAIKIN Cora FTKM20Q2VMA - Cleaning and Replacement - 1

text_image Claw Filter (small)
  1. Clean or replace.

[Cleaning]

Deodorizing filter (enzyme blue) : Blue / Titanium apatite deodorizing filter : Blue-Black

3-1 Vacuum dust, and soak in lukewarm water or water for about 10 to 15 minutes if very dirty.
3-2 After washing, shake off remaining water and let them dry in the shade.

- This filter can be renewed by washing it with water once every 6 months and we recommend replacing it once every 3 years.

- Do not wiring out the filter when removing water from it.

Air quality filter (enzyme blue with PM2.5) : Blue-White / Dust collection filter (PM 2.5) : White

- Do not wash the filters as this will reduce their efficiency.

- It is recommended to replace it once every 6 months.

[Replacement]

Remove the filter from the filter frame and prepare a new one.

  • Do not throw away the filter frame.
    Reuse the filter frame when replacing the filter.
  • When attaching the filter, check that the filter is properly set in the tabs.

DAIKIN Cora FTKM20Q2VMA - Cleaning and Replacement - 2

  1. Set the filters as they were and close the front panel.

- Press the front panel at both sides and the center.

NOTE

• Operation with dirty filters:
- cannot deodorise the air,
- cannot clean the air,
– results in poor heating or cooling,
- may cause odour.
- Dispose of old filters as non-flammable waste.

Care and Cleaning

■ Prior to a long period of non-use

  1. Operate the FAN mode for several hours on a fine day to dry out the inside.

1) Press and select "".
2) Press ⏻ and start the operation.

  1. After operation stops, turn off the circuit breaker for the room air conditioner.
  2. Clean the air filters and reattach them. ▶Page 29
  3. To prevent battery leakage, take out the batteries from the remote controller.

■ We recommend periodical maintenance

  • In certain operating conditions, the inside of the air conditioner may get foul after several seasons of use, resulting in poor performance. It is recommended to have periodical maintenance by a specialist in addition to regular cleaning by the user.
  • For specialist maintenance, please contact the dealer where you bought the air conditioner.
  • The maintenance cost must be borne by the user.

FAQ

Indoor unit

The flaps do not start swinging immediately.

- The air conditioner is adjusting the position of the flaps. The flaps will start moving soon.

The air conditioner stops generating airflow during HEAT operation.

- Once the set temperature is reached, the airflow rate is reduced and operation stopped in order to avoid generating a cool airflow. Operation will resume automatically when the indoor temperature falls.

HEAT operation stops suddenly and a flowing sound is heard.

- The outdoor unit is defrosting. HEAT operation starts after the frost on the outdoor unit has been removed. This can take about 4 to 12 minutes.

Operation does not start soon.

■ When ⏻ was pressed soon after operation was stopped.

■ When the mode was reselected.

• This is to protect the air conditioner. You should wait for about 3 minutes.

Outdoor unit

The outdoor unit emits water or steam.

In HEAT operation

- The frost on the outdoor unit melts into water or steam when the air conditioner is in defrosting operation.

■ In COOL or DRY operation

- Moisture in the air condenses into water on the cool surface of the outdoor unit piping and drips.

Different sounds are heard.

■ A sound like flowing water

  • This sound is generated because the refrigerant in the air conditioner is flowing.
  • This is a pumping sound of the water in the air conditioner and can be heard when the water is pumped out from the air conditioner during COOL or DRY operation.

■ Blowing sound

- This sound is generated when the flow of the refrigerant in the air conditioner is switched over.

■ Ticking sound

- This sound is generated when the cabinet and frame of the air conditioner slightly expand or shrink as a result of temperature changes.

■ Whistling sound

- This sound is generated when refrigerant flows during defrosting operation.

- Clicking sound during operation or idle time

- This sound is generated when the refrigerant control valves or the electrical parts operate.

■ Clopping sound

- This sound is heard from the inside of the air conditioner when the exhaust fan is activated while the room doors are closed. Open the window or turn off the exhaust fan.

■ Rotating machinery causes sound

- Sound is heard when the vertical swing flaps and the horizontal swing flaps move.

- When the air conditioner is operating in a quiet environment and the airflow rate of the indoor unit is set to Quiet Mode or Low Mode, the motion of the swing flaps may cause sound.

DAIKIN Cora FTKM20Q2VMA - Different sounds are heard. - 1

natural_image Illustration of a large industrial air conditioning unit with cooling fan and ventilation grilles (no text or symbols)

Troubleshooting

Before making an inquiry or a request for repair, please check the following.

If the problem persists, consult your dealer.

DAIKIN Cora FTKM20Q2VMA - Troubleshooting - 1

Not a problem

This case is not a problem.

DAIKIN Cora FTKM20Q2VMA - Not a problem - 1

Check

Please check again before requesting repairs.

The air conditioner does not operate

Case Description / what to check
OPERATION lamp is off.Has the circuit breaker been tripped or the fuse blown?Is there a power failure?Are batteries set in the remote controller?
OPERATION lamp is blinking.Turn off the power with the circuit breaker and restart operation with the remote controller.If the OPERATION lamp is still blinking, check the error code and consult your dealer.

The air conditioner suddenly stops operating

Case Description / what to check
OPERATION lamp is on.To protect the system, the air conditioner may stop operating after sudden large voltage fluctuations. It automatically resumes operation in about 3 minutes.
OPERATION lamp is blinking.Is there anything blocking the air inlet or air outlet of the indoor unit or outdoor unit?Stop operation and after turning off the circuit breaker, remove the obstruction. Then restart operation with the remote controller. If the OPERATION lamp is still blinking, check the error code and consult your dealer.Page 36Are operation modes all the same for indoor units connected to the outdoor unit in the multi system? If not, set all indoor units to the same operation mode and confirm that the lamps blink.If the lamps stop blinking after the above steps, there is no malfunction.

The air conditioner does not stop operating

Case Description / what to check
The air conditioner continues operating even after operation is stopped.☑ Immediately after the air conditioner is stopped• The outdoor unit fan continues rotating for about another 1 minute to protect the system.• While the air conditioner is not in operation• When the outdoor temperature is high, the outdoor unit fan may start rotating to protect the system.

The room does not cool down / warm up

Case Description / what to check
Air does not come out.☑ In HEAT operationThe air conditioner is warming up. Wait for about 1 to 4 minutes.During defrosting operation, hot air does not flow out of the indoor unit.When the air conditioner operates immediately after the circuit breaker is turned onThe air conditioner is preparing to operate. Wait for about 3 to 15 minutes.
Air does not come out / Air comes out.? Is the airflow rate setting appropriate?Is the airflow rate setting low, such as “Indoor unit quiet” or “Airflow rate 1”? Increase the airflow rate setting.Is the set temperature appropriate?Is the adjustment of the airflow direction appropriate?
Air comes out.? Is there any furniture directly under or beside the indoor unit?Is the air conditioner in ECONO operation or OUTDOOR UNIT QUIET operation? ▶Page 18Are the air filters dirty?Is there anything blocking the air inlet or air outlet of the indoor unit or outdoor unit?Is a window or door open?Is an exhaust fan turning?

Mist comes out

Case Description / what to check
Mist comes out of the indoor unit.This happens when the air in the room is cooled into mist by the cold airflow during COOL or other operation.

Remote controller

Case Description / what to check
The unit does not receive signals from the remote controller or has a limited operating range.The batteries may be exhausted.Replace both batteries with new dry batteries AAA.LR03 (alkaline).For details, refer to “Preparation Before Operation”. ▶Page 9Signal communication may be disabled if an electronic-starter-type fluorescent lamp (such as inverter-type lamps) is in the room. Consult your dealer if that is the case.The remote controller may not function correctly if the transmitter is exposed to direct sunlight.
LCD is faint, is not working, or the display is erratic.The batteries may be exhausted.Replace both batteries with new dry batteries AAA.LR03 (alkaline).For details, refer to “Preparation Before Operation”. ▶Page 9
The LCD is blinking and the remote controller cannot be operated.Battery power has run out.Replace both batteries at the same time with new size AAA.LR03 (alkaline) batteries.Leaving exhausted batteries in the remote controller can result in injury due to battery leakage, rupturing or heating, or lead to equipment failure.(Even when the LCD is blinking, the OFF button remains functional.)
Other electric devices start operating.If the remote controller activates other electric devices, move them away or consult your dealer.

Air has an odour

Case Description / what to check
The air conditioner gives off an odour.The room odour absorbed in the unit is discharged with the airflow.We recommend you to have the indoor unit cleaned. Please consult your dealer.

Others

Case Description / what to check
The air conditioner suddenly starts behaving strangely during operation.The air conditioner may malfunction due to lightning or radio.If the air conditioner malfunctions, turn off the power with the circuit breaker and restart the operation with the remote controller.
The ON/OFF TIMER does not operate according to the settings.Check if the ON/OFF TIMER and the WEEKLY TIMER are set to the same time.Change or deactivate the settings in the WEEKLY TIMER. ▶Page 22

NOTE

Notes on the operating conditions

  • If operation continues under any conditions other than those listed in the table,
  • A safety device may activate to stop the operation.
  • Dew may form on the indoor unit and drip from it when COOL or DRY operation is selected.
Mode Operating conditions
COOL / DRYOutdoor temperature: -10.0~46.0°CIndoor temperature: 18.0~32.0°CIndoor humidity: 80% max.
HEATOutdoor temperature: -15.0~24.0°CIndoor temperature: 10.0~30.0°C

■ Call your dealer immediately

DAIKIN Cora FTKM20Q2VMA - ■ Call your dealer immediately - 1

WARNING

When an abnormality (such as a burning smell) occurs, stop operation and turn off the circuit breaker.

  • Continued operation in an abnormal condition may result in problems, electric shock or fire.
  • Consult the dealer where you bought the air conditioner.

Do not attempt to repair or modify the air conditioner by yourself.

  • Incorrect work may result in electric shock or fire.
  • Consult the dealer where you bought the air conditioner.

If one of the following symptoms takes place, call your dealer immediately.

  • The power cord is abnormally hot or damaged.
  • An abnormal sound is heard during operation.
  • The circuit breaker, a fuse, or the earth leakage circuit breaker cuts off the operation frequently.
  • A switch or a button often fails to work properly.
    • There is a burning smell.
    • Water leaks from the indoor unit.

Turn off the circuit breaker and call your dealer.

DAIKIN Cora FTKM20Q2VMA - If one of the following symptoms takes place, call your dealer immediately. - 1

■ After a power failure

- The air conditioner automatically resumes operation in about 3 minutes. Please wait for a while.

Lightning

- If there is a risk lightning could strike in the neighbourhood, stop operation and turn off the circuit breaker to protect the system.

■ Disposal requirements

- Dismantling of the unit, handling of the refrigerant, oil and other parts, should be done in accordance with the relevant local and national regulations.

DAIKIN Cora FTKM20Q2VMA - ■ Disposal requirements - 1

text_image ON 88.8°C MON FUE WD ON 38.88 THU FRI ON 38.88g SAT SUN 8 ON 38.88g Cancel Timer

■ Fault diagnosis by remote controller

- In case the air conditioner is malfunctioning, you can check the error code via the remote controller before consulting with service personnel and informing them of the malfunction code.

2. Press Cancel repeatedly until a long beep is produced.

- The code indication changes as shown below, and notifies you with a long beep.

CODE MEANING
SYSTEM00 NORMAL
UA INDOOR-OUTDOOR UNIT COMBINATION FAULT
U0 REFRIGERANT SHORTAGE
U2 DROP VOLTAGE OR MAIN CIRCUIT OVERVOLTAGE
U4 FAILURE OF TRANSMISSION (BETWEEN INDOOR UNIT AND OUTDOOR UNIT)
INDOOR UNITA1 INDOOR PCB DEFECTIVENESS
A5 HIGH PRESSURE CONTROL OR FREEZE-UP PROTECTOR
A6 FAN MOTOR FAULT
C4 FAULTY HEAT EXCHANGER TEMPERATURE SENSOR
C9 FAULTY SUCTION AIR TEMPERATURE SENSOR
OUTDOOR UNITEACOOLING-HEATING SWITCHING ERROR
E1 CIRCUIT BOARD FAULT
E5 OL STARTED
E6 FAULTY COMPRESSOR START UP
E7 DC FAN MOTOR FAULT
E8 OVERCURRENT INPUT
F3 HIGH TEMPERATURE DISCHARGE PIPE CONTROL
F6 HIGH PRESSURE CONTROL (IN COOLING)
H0 SENSOR FAULT
H6 OPERATION HALT DUE TO FAULTY POSITION DETECTION SENSOR
H8 DC CURRENT SENSOR FAULT
H9 FAULTY SUCTION AIR TEMPERATURE SENSOR
J3FAULTY DISCHARGE PIPE TEMPERATURE SENSOR
J6FAULTY HEAT EXCHANGER TEMPERATURE SENSOR
L3 ELECTRICAL PARTS HEAT FAULT
L4 HIGH TEMPERATURE AT INVERTER CIRCUIT HEATSINK
L5 OUTPUT OVERCURRENT
P4 FAULTY INVERTER CIRCUIT HEATSINK TEMPERATURE SENSOR

NOTE

  • A short beep and 2 consecutive beeps indicates non-corresponding codes.
  • To cancel the code display, hold □ down for about 5 seconds. The code display also clears if no button is pressed for 1 minute.

MEMO

Quick Reference
DAIKIN Cora FTKM20Q2VMA - MEMO - 1

text_image ON 27.0°C MON 15:30 On/OffFAN Temp Mode Swing 10°C ← 30°C 18°C ← 32°C 18°C ← 30°C

DAIKIN Cora FTKM20Q2VMA - MEMO - 2

flowchart
graph TD
    A["MODE"] --> B["A"]
    B --> C["Temperature Control"]
    C --> D["Lightning System"]
    D --> E["Lighting System"]
    E --> F["Lighting System"]
    F --> G["Lighting System"]
    G --> H["Lighting System"]
    H --> I["Lighting System"]
    I --> J["Lighting System"]
    J --> K["Lighting System"]
    K --> L["Lighting System"]
    L --> M["Lighting System"]
    M --> N["Lighting System"]
    N --> O["Lighting System"]
    O --> P["Lighting System"]
    P --> Q["Lighting System"]
    Q --> R["Lighting System"]
    R --> S["Lighting System"]
    S --> T["Lighting System"]
    T --> U["Lighting System"]
    U --> V["Lighting System"]
    V --> W["Lighting System"]
    W --> X["Lighting System"]
    X --> Y["Lighting System"]
    Y --> Z["Lighting System"]
    Z --> AA["Lighting System"]
    AA --> AB["Lighting System"]
    AB --> AC["Lighting System"]
    AC --> AD["Lighting System"]
    AD --> AE["Lighting System"]
    AE --> AF["Lighting System"]
    AF --> AG["Lighting System"]
    AG --> AH["Lighting System"]
    AH --> AI["Lighting System"]
    AI --> AJ["Lighting System"]
    AJ --> AK["Lighting System"]
    AK --> AL["Lighting System"]
    AL --> AM["Lighting System"]
    AM --> AN["Lighting System"]
    AN --> AO["Lighting System"]
    AO --> AP["Lighting System"]
    AP --> AQ["Lighting System"]
    AQ --> AR["Lighting System"]
    AR --> AS["Lighting System"]
    AS --> AT["Lighting System"]
    AT --> AU["Lighting System"]
    AU --> AV["Lighting System"]
    AV --> AW["Lighting System"]
    AW --> AX["Lighting System"]
    AX --> AY["Lighting System"]

DAIKIN INDUSTRIES, LTD.

Head office:

Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,

Kita-ku, Osaka, 530-8323 Japan

Tokyo office:

JR Shinagawa East Bldg., 2-18-1, Konan,

Minato-ku, Tokyo, 108-0075 Japan

https://www.daikin.com

DAIKIN Cora FTKM20Q2VMA - DAIKIN INDUSTRIES, LTD. - 1

The two-dimensional bar code is a manufacturing code.

OPERATION MANUAL

DAIKIN ROOM AIR CONDITIONER

DAIKIN Cora FTKM20Q2VMA - OPERATION MANUAL - 1

natural_image Line drawing of a single air conditioner unit (no text or symbols)

MODELS

FTKM20Q2VMA
FTKM25Q2VMA
FTKM35Q2VMA
FTKM46Q2VMA

DAIKIN Cora FTKM20Q2VMA - MODELS - 1

natural_image Illustration of a city skyline above Earth with continents and oceans (no text or symbols)

Features

Enhanced comfort and energy savings

DAIKIN Cora FTKM20Q2VMA - Enhanced comfort and energy savings - 1

INTELLIGENT EYE

The INTELLIGENT EYE sensor detects human movement and adjusts the right and left airflow direction. If no one is in the room for more than 20 minutes, the operation automatically changes to energy saving operation. The INTELLIGENT EYE sensor works differently depending on the situation. ▶ Page 16

DAIKIN Cora FTKM20Q2VMA - INTELLIGENT EYE - 1

WEEKLY TIMER

Up to 4 timer settings can be saved for each day of the week according to your family's life style. The WEEKLY TIMER allows you to set on/off times and the desired temperature. ▶ Page 23

Other functions

DAIKIN Cora FTKM20Q2VMA - Other functions - 1

COMFORT AIRFLOW OUTDOOR UNIT QUIET

The airflow direction is upward while in COOL operation, and downward while in HEAT operation. This function prevents cold or warm air from blowing directly on your body. ▶ Page 15

DAIKIN Cora FTKM20Q2VMA - COMFORT AIRFLOW OUTDOOR UNIT QUIET - 1

OUTDOOR UNIT QUIET operation assures a low noise level of the outdoor unit. This function is useful to maintain a quiet neighbourhood.

Page 19

DAIKIN Cora FTKM20Q2VMA - COMFORT AIRFLOW OUTDOOR UNIT QUIET - 2

natural_image Modern minimalist living room interior with white sofa, wall-mounted air conditioner, and potted plant (no text or symbols visible)

DAIKIN Cora FTKM20Q2VMA - COMFORT AIRFLOW OUTDOOR UNIT QUIET - 3

ECONO

This function enables efficient operation by limiting the maximum power consumption. It is useful when using the air conditioner and other electrical devices simultaneously on a shared electrical circuit. Page 19

Contents

Read Before Operation

Safety Precautions 3

Names of Parts 5

Preparation Before Operation 9

Basic Operation

DAIKIN Cora FTKM20Q2VMA - Basic Operation - 1

DRY · COOL · FAN Operation...... 11

DAIKIN Cora FTKM20Q2VMA - Basic Operation - 2

Adjusting the Airflow Direction...... 13

DAIKIN Cora FTKM20Q2VMA - Basic Operation - 3

Adjusting the Airflow Rate...... 14

Useful Functions

DAIKIN Cora FTKM20Q2VMA - Useful Functions - 1

COMFORT AIRFLOW Operation.....15

DAIKIN Cora FTKM20Q2VMA - Useful Functions - 2

INTELLIGENT EYE Operation...... 16

DAIKIN Cora FTKM20Q2VMA - Useful Functions - 3

POWERFUL Operation.... 18

DAIKIN Cora FTKM20Q2VMA - Useful Functions - 4

ECONO/OUTDOOR UNIT QUIET Operation.... 19

TIMER Operation

DAIKIN Cora FTKM20Q2VMA - TIMER Operation - 1

ON/OFF TIMER Operation...... 20

DAIKIN Cora FTKM20Q2VMA - TIMER Operation - 2

WEEKLY TIMER Operation......23

Care

Care and Cleaning 29

■ When the Need Arises

FAQ 34

Troubleshooting 35

Safety Precautions

DAIKIN Cora FTKM20Q2VMA - Safety Precautions - 1

Read the precautions in this manual carefully before operating the unit.

DAIKIN Cora FTKM20Q2VMA - Safety Precautions - 2

This appliance is filled with R32.

  • Keep this manual where the user can easily find it.
  • The precautions described herein are classified as WARNING and CAUTION. They both contain important information regarding safety. Be sure to observe all precautions without fail.

DAIKIN Cora FTKM20Q2VMA - Safety Precautions - 3

WARNING

Failure to follow these instructions properly may result in personal injury or loss of life.

DAIKIN Cora FTKM20Q2VMA - WARNING - 1

CAUTION

Failure to follow these instructions properly may result in property damage or personal injury, which may be serious depending on the circumstances.

DAIKIN Cora FTKM20Q2VMA - CAUTION - 1

Never attempt.

DAIKIN Cora FTKM20Q2VMA - CAUTION - 2

Be sure to follow the instructions.

DAIKIN Cora FTKM20Q2VMA - CAUTION - 3

Be sure to establish an earth connection.

DAIKIN Cora FTKM20Q2VMA - CAUTION - 4

Never touch the air conditioner nor the remote controller with wet hands.

DAIKIN Cora FTKM20Q2VMA - CAUTION - 5

Never wet the air conditioner nor the remote controller

• After reading, keep this manual in a convenient place so that you can refer to it whenever necessary. If the equipment is transferred to a new user, be sure also to hand over the manual.

DAIKIN Cora FTKM20Q2VMA - CAUTION - 6

WARNING

DAIKIN Cora FTKM20Q2VMA - WARNING - 1

  • Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
  • The appliance must be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater).
  • Do not pierce or burn.
  • Be aware that refrigerants may not contain an odour.
  • The appliance must be installed, operated and stored in a room with floor area larger than -^*m^2 for 20/25/35/46 class.
    * Since the maximum refrigerant charge of the models is below 1.84kg , it does not have any limitation for the minimum floor area.
    • To avoid fire, explosion or injury, do not operate the unit when harmful gases (e.g. flammable or corrosive) are detected near the unit.
  • Be aware that prolonged, direct exposure to cool or warm air from the air conditioner, or to air that is too cool or too warm, can be harmful to your physical condition and health.
  • Do not place objects, including rods, your fingers, etc., in the air inlet or outlet. Product damage or personal injury may result due to contact with the air conditioner's high-speed fan blades.
  • Do not attempt to repair, dismantle, reinstall or modify the air conditioner yourself as this may result in water leakage, electric shocks or fire hazards.
  • Do not use flammable spray near the air conditioner, or otherwise fire may result.
  • When the air conditioner is malfunctioning (giving off a burning odour, etc.) turn off power to the unit and contact your local dealer. Continued operation under such circumstances may result in a failure, electric shocks or fire hazards.
  • Do not use a refrigerant other than the one indicated on the outdoor unit (R32) when installing, moving or repairing. Using other refrigerants may cause trouble or damage to the unit, and personal injury.

DAIKIN Cora FTKM20Q2VMA - WARNING - 2

- To avoid electric shocks, do not operate with wet hands.

DAIKIN Cora FTKM20Q2VMA - WARNING - 3

- Beware of fire in case of refrigerant leakage. If the air conditioner is not operating correctly, i.e. not generating cool or warm air, refrigerant leakage could be the cause. Consult your dealer for assistance. The refrigerant within the air conditioner is safe and normally does not leak.

However, in the event of a leakage, contact with a naked burner, heater or cooker may result in generation of noxious gas. Do not use the air conditioner until a qualified service person confirms that the leakage has been repaired.

  • Do not attempt to install or repair the air conditioner yourself. Improper workmanship may result in water leakage, electric shocks or fire hazards. Please contact your local dealer or qualified personnel for installation and maintenance work.
  • If the air conditioner is malfunctioning (giving off a burning odour, etc.), turn off power to the unit and contact your local dealer. Continued operation under such circumstances may result in a failure, electric shocks or fire hazards.
  • Be sure to install an earth leakage circuit breaker. Failure to install an earth leakage circuit breaker may result in electric shocks or fire.
  • Be sure to earth the unit. Do not earth the unit to a utility pipe, lightning conductor or telephone earth lead. Imperfect earthing may result in electric shocks.

DAIKIN Cora FTKM20Q2VMA - WARNING - 4

CAUTION

DAIKIN Cora FTKM20Q2VMA - CAUTION - 1

  • Do not use the air conditioner for purposes other than those for which it is intended. Do not use the air conditioner for cooling precision instruments, food, plants, animals or works of art as this may adversely affect the performance, quality and/or longevity of the object concerned.
  • Do not expose plants or animals directly to the airflow from the unit as this may cause adverse effects.
  • Do not place appliances that produce naked flames in places exposed to the airflow from the unit as this may impair combustion of the burner.

DAIKIN Cora FTKM20Q2VMA - CAUTION - 2

CAUTION

DAIKIN Cora FTKM20Q2VMA - CAUTION - 1

  • Do not block the air inlets nor outlets. Impaired airflow may result in insufficient performance or trouble.
  • Do not sit on the outdoor unit, put things on the unit, or pull the unit. Doing so may cause accidents, such as falling or toppling down, thus resulting in injury, product malfunctioning, or product damage.
  • Do not give impact to the indoor and outdoor units, or otherwise product damage may result.
  • Do not place objects that are susceptible to moisture directly beneath the indoor or outdoor units. Under certain conditions, condensation on the main unit or refrigerant pipes, air filter dirt or drain blockage may cause dripping, resulting in fouling or failure of the object concerned.
  • After prolonged use, check the unit stand and its mounts for damage. If they are left in a damaged condition, the unit may fall and cause injury.
  • To avoid injury, do not touch the air inlet or aluminium fins of the indoor or outdoor units.
  • The appliance is not intended for use by unattended young children or infirm persons. Impairment of bodily functions and harm to health may result.
  • Children should be supervised to ensure that they do not play with the unit or its remote controller. Accidental operation by a child may result in impairment of bodily functions and harm health.
  • Do not place flammable items, such as spray cans, within 1m of the air outlet.
    The spray cans may explode as a result of hot air from the indoor or outdoor units.
  • Be careful not to let pets urinate on the air conditioner. Urination on the air conditioner may result in electric shocks or fire.
  • Do not sit or hang on the panel. The panel may fall, and injury or product malfunctioning may result.
  • Do not sway the panel. The panel may hit people or objects, and injury or property damage may result.
  • Do not let children play around the panel. Injury or property damage may result.
  • Do not pull the wires. The wires may be broken and the panel may fall, and injury or property damage may result.
  • Do not locate obstacles in the route. The panel may fall, and injury or property damage may result.
  • Do not bend or damage the wires. The wires may be broken and the panel may fall, and injury or property damage may result.
  • Do not wash the air conditioner with water, as this may result in electric shocks or fire.
  • Do not place water containers (vases, etc.) above the unit, as this may result in electric shocks or fire hazards if they should topple over.
  • Do not put objects on the panel, or otherwise production malfunctioning may result.
  • Do not use an unstable stand at the time of operating or maintaining the air conditioner, or otherwise you may topple over or injury yourself.
  • Locate the remote controller in places out of reach of children. The wrong operation of the remote controller may result in injury.
  • To avoid oxygen depletion, ensure that the room is adequately ventilated if equipment such as a burner is used together with the air conditioner.
  • Before cleaning, be sure to stop unit operation and turn off the circuit breaker. Otherwise, an electric shock and injury may result.
  • Only connect the air conditioner to the specified power supply circuit. Power supplies other than the one specified may result in electric shocks, overheating and fires.
  • Arrange the drain hose to ensure smooth drainage. Imperfect drainage may cause wetting of the building, furniture, etc.
  • Do not place objects in direct proximity of the outdoor unit and do not let leaves and other debris accumulate around the unit. Leaves are a hotbed for small animals which can enter the unit. Once inside the unit, such animals can cause malfunctions, smoke or fire if they come into contact with electrical parts.
  • Do not place objects around the indoor unit.
    Doing so may have an adverse influence on the performance, product quality, and life of the air conditioner.

DAIKIN Cora FTKM20Q2VMA - CAUTION - 2

Installation site

■ To install the air conditioner in the following types of environments, consult your dealer.

  • Places with an oily environment or where steam or soot occurs.
  • Salty environments such as coastal areas.
  • Places where sulphide gas occurs such as hot springs.
  • Places where snow may block the outdoor unit.

■ Be sure to follow the instructions below.

• The indoor unit is at least 1m away from any television or radio set (unit may cause interference with the picture or sound).
- The drain from the outdoor unit must be discharged to a place of good drainage.

Consider nuisance to your neighbours from noises

■ For installation, choose a place as described below.

  • A place solid enough to bear the weight of the unit and which does not amplify the operation noise or vibration.
  • A place from where the air discharged from the outdoor unit or the operation noise will not annoy your neighbours.

Electrical work

■ Fdhe power supply, be sure to use a separate power circuit dedicated to the air conditioner.

System relocation

■ Relocating the air conditioner requires specialized knowledge and skills. Please consult your dealer if relocation is necessary for moving or remodelling.

Names of Parts

Indoor Unit

DAIKIN Cora FTKM20Q2VMA - Indoor Unit - 1

text_image Deodorizing filter (enzyme blue) Air Filter Front panel Air inlet Horizontal blade (Flap) : ▶Page 13 Vertical blades (Louvers) • The Louvers are inside of the air outlet. ▶Page 13 Air outlet Display Name Panel tab INTELLIGENT EYE sensor • Detects the movements of people and automatically switches between normal operation and energy saving operation. ▶Page 16 Room temperature sensor • It senses the air tempera ture around the unit.

Display

Signal receiver

  • It receives signals from the remote controller.
  • When the unit receives a signal, you will hear a short beep.
    • Operation start ...... beep-beep
  • Settings changed .... beep
    • Operation stop ...... beeeeeep

DAIKIN Cora FTKM20Q2VMA - Signal receiver - 1

text_image Operation lamp (green) TIMER lamp (orange) : ▶Page 20,21,22,25,27 ON/OFF INTELLIGENT EYE lamp (green) : ▶Page 16

Indoor Unit ON/OFF switch

  • Push this switch once to start operation. Push once again to stop it.
  • The operation mode refer to the following table.
ModeTemperature settingAirflow rate
COOL22°CAUTO

- This switch can be used when the remote controller is missing.

■ Open the front panel
DAIKIN Cora FTKM20Q2VMA - Indoor Unit ON/OFF switch - 1

text_image Deodorizing filter (enzyme blue) Air filter

Outdoor Unit

■ For 20/25/35 class
DAIKIN Cora FTKM20Q2VMA - Outdoor Unit - 1

text_image Air inlet (back and side) Air outlet Outdoor temperature sensor (back) Refrigerant piping and inter-unit wiring Model name plate Earth terminal (inside) Drain hose

■ For 46 class

DAIKIN Cora FTKM20Q2VMA - Outdoor Unit - 2

text_image Air inlet (back and side) Air outlet Outdoor temperature sensor (back) Refrigerant piping and inter-unit wiring Earth terminal (inside) Drain hose Model name plate

Names of Parts

Remote Controller

DAIKIN Cora FTKM20Q2VMA - Remote Controller - 1

text_image Signal transmitter Receiver To use the remote controller, aim the transmitter at the indoor unit. If there is anything blocking the signals between the unit and the remote controller, such as a curtain, the unit may not operate. The maximum transmission distance is about 7m. Display (LCD) Displays the current settings. (In this illustration, each section is shown with all its displays on for the purpose of explanation.) TEMPERATURE adjustment button Changes the temperature setting. ▶ Page 12 FAN setting button Selects the airflow rate setting. ▶ Page 14 POWERFUL button POWERFUL operation. ▶ Page 18 ON/OFF button Press this button once to start operation. Press once again to stop it. ▶ Page 11 Front cover Open the front cover. ▶ Page 8 Model name ARC466A27

■ Open the front cover

DAIKIN Cora FTKM20Q2VMA - ■ Open the front cover - 1

flowchart
graph TD
    A["MODE selector button"] --> B["SENSOR button"]
    A --> C["COMFORT button"]
    A --> D["OFF TIMER button (NIGHT SET mode)"]
    A --> E["TIMER CANCEL button"]
    A --> F["SELECT button"]
    B --> G["ECONO/QUIET button"]
    C --> H["SWING button"]
    D --> I["ON TIMER button"]
    E --> J["CLOCK button"]
    style A fill:#f9f,stroke:#333
    style B fill:#ccf,stroke:#333
    style C fill:#cfc,stroke:#333
    style D fill:#fcc,stroke:#333
    style E fill:#cff,stroke:#333
    style F fill:#ffc,stroke:#333

Preparation Before Operation

DAIKIN Cora FTKM20Q2VMA - Preparation Before Operation - 1

text_image Position + and - correctly!

*The remote controller may differ from some models.

To insert the batteries

  1. Slide the front cover to take it off.
  2. Insert 2 dry batteries AAA.LR03 (alkaline).
  3. Replace the front cover.

DAIKIN Cora FTKM20Q2VMA - To insert the batteries - 1

text_image Remote controller Screws Remote controller holder

To fix the remote controller holder to a wall

  1. Choose a place from where the signals reach the unit.
  2. Fix the holder to a wall, a pillar, or similar location with the screws supplied with the holder.
  3. Place the remote controller in the remote controller holder.

Turn on the circuit breaker

- After the power is turned on, the flaps of the indoor unit open and close once to set the reference position.

NOTE

Notes on batteries

  • When replacing the batteries, use batteries of the same type, and replace both old batteries together.
  • The batteries will last for about 1 year. If the remote controller display begins to fade and the possible transmission range becomes shorter within a year, however, replace both batteries with new, size AAA.LR03 (alkaline).
  • The batteries supplied with the remote controller are for initial operation. The batteries may run out in less than 1 year.

Note on remote controller

- Do not drop the remote controller. Do not get it wet.

DAIKIN Cora FTKM20Q2VMA - Note on remote controller - 1

text_image 27.0°C MON 15:30 Select Timer

*The remote controller may differ from some models.

To set the clock

1. Press

DAIKIN Cora FTKM20Q2VMA - Press - 1

"0.00 is displayed on the LCD.

"MON" and "④ blink.

2. Press to set the current day of the week.

3. Press

DAIKIN Cora FTKM20Q2VMA - Press - 1

" blinks.

4. Press to set the clock to the present time.

- Holding down ▲ or ▼ rapidly increases or decreases the displayed time.

5. Press

- Point the remote controller at the indoor unit when pressing the buttons.

DAIKIN Cora FTKM20Q2VMA - Press - 1

“*” blinks.

NOTE

Note on setting the clock

- If the indoor unit's internal clock is not set to the correct time, the ON/OFF TIMER and WEEKLY TIMER will not operate punctually.

DAIKIN Cora FTKM20Q2VMA - Note on setting the clock - 1

DRY · COOL · FAN Operation

DAIKIN Cora FTKM20Q2VMA - DRY · COOL · FAN Operation - 1

text_image ON 27.0°C * A MON 15:30 On/Off Mode Timer

The air conditioner operates with the operation mode of your choice.

From the next time on, the air conditioner will operate with the same operation mode.

To start operation

1. Press and select a operation mode.

• Each pressing of the button changes the mode setting in sequence.

DAIKIN Cora FTKM20Q2VMA - Press and select a operation mode. - 1

flowchart
graph LR
    A["Start"] --> B["Step 1: 📋"]
    B --> C["Step 2: ✦"]
    C --> D["Step 3: 🍀️"]
    D --> E["End"]

2. Press On/Off

• “ON displayed on the LCD.
• The OPERATION lamp lights green.

DAIKIN Cora FTKM20Q2VMA - Press On/Off - 1

text_image Simple diagram with a rectangle, lightbulb, clock, and small figures below, possibly representing a system or process.

Display

To stop operation

Press again.

  • “ On appears from the LCD.
    • The OPERATION lamp goes off.

NOTE

Note on DRY operation

- Eliminates humidity while maintaining the indoor temperature as much as possible. It automatically controls temperature and airflow rate, so manual adjustment of these functions is unavailable.

DAIKIN Cora FTKM20Q2VMA - Note on DRY operation - 1

text_image ON 27.0°C MON 15:30 Temp Timer

To change the temperature setting

DAIKIN Cora FTKM20Q2VMA - To change the temperature setting - 1

Press

DAIKIN Cora FTKM20Q2VMA - Press - 1

- Press ▲ to raise the temperature and press ▼ to lower the temperature.

COOL operationDRY or FAN operation
18.0 – 32.0°CThe temperature setting cannot be changed.

Tips for saving energy

Keeping the temperature setting at a moderate level helps save energy.

- Recommended temperature setting

- For cooling : 26.0-28.0°C

Cover windows with a blind or a curtain.

- Blocking sunlight and air from outdoors increases the cooling effect.

Keep the air filters clean.

• Clogged air filters cause inefficient operation and waste energy. Clean them once in about every 2 weeks. ▶ Page 31

DAIKIN Cora FTKM20Q2VMA - Tips for saving energy - 1

natural_image Stylized plant branch illustration with leaves and stems, rendered in grayscale geometric shapes (no text or symbols)

If you are not going to use the air conditioner for a long period, for example in spring or autumn, turn off the circuit breaker.

- The air conditioner always consumes a small amount of electricity even while it is not operating.

DAIKIN Cora FTKM20Q2VMA - Tips for saving energy - 2

Adjusting the Airflow Direction

DAIKIN Cora FTKM20Q2VMA - Adjusting the Airflow Direction - 1

text_image MASTER * 27.0°C A MON 15:30 Switch Timer

You can adjust the airflow direction to increase your comfort.

ATTENTION

• Always use a remote controller to adjust the angles of the flaps and louvres.
- If you attempt to move the flaps and louvres forcibly by hand when they are swinging, the mechanism may be damaged.
- Inside the air outlet, a fan is rotating at a high speed.

To start auto swing

Up and down airflow direction

DAIKIN Cora FTKM20Q2VMA - Up and down airflow direction - 1

Press

DAIKIN Cora FTKM20Q2VMA - Press - 1

  • “C” is displayed on the LCD.
  • The flaps (horizontal blades) will begin to swing.

DAIKIN Cora FTKM20Q2VMA - Press - 2

natural_image Diagram showing a circular icon with rotation arrows and a server icon, no text or symbols present

Right and left airflow direction

DAIKIN Cora FTKM20Q2VMA - Right and left airflow direction - 1

Press

DAIKIN Cora FTKM20Q2VMA - Press - 1

• “” is displayed on the LCD.
• The louvres (vertical blades) will begin to swing.

DAIKIN Cora FTKM20Q2VMA - Press - 2

natural_image Diagram showing airflow around a car with a curved arrow indicating direction (no text or symbols)

The 3-D airflow direction

DAIKIN Cora FTKM20Q2VMA - The 3-D airflow direction - 1

Press

DAIKIN Cora FTKM20Q2VMA - Press - 1

  • “ ⏻” and “ 📋” are displayed on the LCD.
    • The flaps and louvres move in turn.
  • To cancel 3-D airflow, press either 📁 or again. The flaps or louvres will stop moving.

DAIKIN Cora FTKM20Q2VMA - Press - 2

natural_image Diagram showing airflow around a car air conditioner unit (no text or symbols)

To set the flaps or louvres at the desired position

- This function is effective while the flaps or louvres are in auto swing mode.

DAIKIN Cora FTKM20Q2VMA - To set the flaps or louvres at the desired position - 1

sserP

DAIKIN Cora FTKM20Q2VMA - sserP - 1

whandthe flaps or louvres

reach the desired position.

• In the 3-D airflow, the flaps and louvres move in turn.
- “” or “” disappears from the LCD.

DAIKIN Cora FTKM20Q2VMA - reach the desired position. - 1

Adjusting the Airflow Rate

DAIKIN Cora FTKM20Q2VMA - Adjusting the Airflow Rate - 1

text_image 27:0 MON 15:30 Fan

You can adjust the airflow rate to increase your comfort.

To adjust the airflow rate setting

DAIKIN Cora FTKM20Q2VMA - To adjust the airflow rate setting - 1

• Each pressing of fan changes the airflow rate setting in sequence.

DAIKIN Cora FTKM20Q2VMA - To adjust the airflow rate setting - 2

flowchart
graph LR
    A["AUTO"] --> B["Indoor unit quiet"]
    B --> C["Airflow rate 1-5 (Low to High)"]
  • When operation starts and noise from the indoor unit will become quieter.
  • In the quiet operation mode, the airflow rate is set to a weak level.
COOL and FAN operation DRY operation
The airflow rate setting cannot be changed.

NOTE

Note on airflow direction setting

- The movable range of the flaps varies according to the operation mode.

Movable range of the flap

DAIKIN Cora FTKM20Q2VMA - Note on airflow direction setting - 1

text_image of the flap COOL / DRY FAN

Note on 3-D airflow

- Using 3-D airflow circulates cold air, which tends to collected at the bottom of the room, and hot air, which tends to collect near the ceiling, throughout the room, preventing areas of cold and hot developing.

Note on airflow rate setting

- At smaller airflow rates, the cooling effect is also smaller.

DAIKIN Cora FTKM20Q2VMA - Note on airflow rate setting - 1

COMFORT AIRFLOW Operation

DAIKIN Cora FTKM20Q2VMA - COMFORT AIRFLOW Operation - 1

text_image 27.0°C MON 15:30 Comfort Timer

COMFORT AIRFLOW operation: The air direction and flow rate are adjusted so that the air will not blow directly at people in the room.

To start COMFORT AIRFLOW operation

DAIKIN Cora FTKM20Q2VMA - To start COMFORT AIRFLOW operation - 1

• “ 🍴 is displayed on the LCD.

COOL and DRY operation FAN operation
Flap directionGoes upNot available
Airflow rateAUTO

To cancel COMFORT AIRFLOW operation

Press again.

• “ disappears from the LCD.
- The flap will return to the memory position from before COMFORT AIRFLOW operation.

Notes on "COMFORT AIRFLOW Operation"

• The flap position will change, preventing air from blowing directly on the occupants of the room.
- POWERFUL operation and COMFORT AIRFLOW operation cannot be used at the same time.
- The volume of air will be set to AUTO. If the upward and downward airflow direction is selected, the COMFORT AIRFLOW function will be canceled.
- Priority is given to the function of whichever button is pressed last.
- The COMFORT AIRFLOW function makes the following airflow direction adjustments. The flaps will move upward while cooling so that the airflow will be directed upward.

DAIKIN Cora FTKM20Q2VMA - Notes on "COMFORT AIRFLOW Operation" - 1

natural_image Diagram of a airflow or ventilation system with a mounted air conditioner unit (no text or symbols)

Cooling operation

DAIKIN Cora FTKM20Q2VMA - Notes on "COMFORT AIRFLOW Operation" - 2

INTELLIGENT EYE Operation

DAIKIN Cora FTKM20Q2VMA - INTELLIGENT EYE Operation - 1

text_image 27.0°C MON 15:30 Sensor Timer

The INTELLIGENT EYE operation detects human movement and adjusts airflow direction. It can be set to avoid people or to direct airflow specifically at people. If no one is detected in the room for more than 20 minutes, the unit automatically enters energy saving operation.

CAUTION

  • Do not place large objects near the INTELLIGENT EYE sensor. Also keep heating units and humidifiers outside the sensor's detection area. This sensor can detect undesirable objects.
  • Do not hit or violently push the INTELLIGENT EYE sensor. This can lead to damage and malfunction.

To start INTELLIGENT EYE operation

DPress

DAIKIN Cora FTKM20Q2VMA - DPress - 1

and select the desired model.

• Each time is pressed, a different setting option is displayed on the LCD.
• The INTELLIGENT EYE lamp lights green.

DAIKIN Cora FTKM20Q2VMA - and select the desired model. - 1

text_image Simple diagram with a person, clock, and sun icons, possibly representing a conceptual or educational concept.

Display

DAIKIN Cora FTKM20Q2VMA - and select the desired model. - 2

flowchart
graph LR
    A["Directly on people"] --> B["Blow directly on people"]
    B --> C["blank\nNo Setting"]
    C --> D["Do not blow"]
  • When the flaps (horizontal blades) are swinging, selecting any of the modes above will cause the flaps (horizontal blades) to stop.
    • The lamp lights when human movement is detected.

To cancel the INTELLIGENT EYE operation

Press

DAIKIN Cora FTKM20Q2VMA - Press - 1

button.

• The INTELLIGEN EYE lamp goes off.

NOTE

• INTELLIGENT EYE operation is set to blow directly on people, the air conditioner tracks you horizontally, without the air blowing directly on you.
- When the INTELLIGENT EYE sensor detects the movement of people, it adjusts the airflow direction upward (while in COOL operation) adjusting the flaps. Depending on the settings, the louvres (vertical blades) will either direct airflow directly toward or away from people.

DAIKIN Cora FTKM20Q2VMA - NOTE - 1

INTELLIGENT EYE Operation

How the INTELLIGENT EYE operation works

The INTELLIGENT EYE sensor detects human movement and adjusts the right and left direction. If no one is in the room for more than 20 minutes, the operation automatically changes to energy saving operation. The INTELLIGENT EYE sensor works differently depending on the situation.

[Example]

A person is detected in area 1.A person is detected in area 2.People are detected in both areas.No people are detected in the areas.
DAIKIN Cora FTKM20Q2VMA - How the INTELLIGENT EYE operation works - 1DAIKIN Cora FTKM20Q2VMA - How the INTELLIGENT EYE operation works - 2DAIKIN Cora FTKM20Q2VMA - How the INTELLIGENT EYE operation works - 3DAIKIN Cora FTKM20Q2VMA - How the INTELLIGENT EYE operation works - 4When the INTELLIGENT EYE operation and the COMFORT AIRFLOW operation are used together, the unit will not blow air directly at people (only in their general direction).DAIKIN Cora FTKM20Q2VMA - How the INTELLIGENT EYE operation works - 5The air conditioner will switch to energy-saving mode after 20 minutes.
DAIKIN Cora FTKM20Q2VMA - How the INTELLIGENT EYE operation works - 6DAIKIN Cora FTKM20Q2VMA - How the INTELLIGENT EYE operation works - 7DAIKIN Cora FTKM20Q2VMA - How the INTELLIGENT EYE operation works - 8

* The airflow direction may differ from the illustrated direction depending on the actions and movements of the people in the areas.

INTELLIGENT EYE operation is useful for energy saving

Energy saving operation

  • If no presence detected in the room for 20 minutes, energy saving operation starts automatically.
  • This operation changes the temperature by -2^ in HEAT / +2^ in COOL / +2^ in DRY operation from the set temperature.
    When the room temperature exceeds 30^ C, the operation changes the temperature by +1^ C in COOL / +1^ C in DRY operation from the set temperature.
  • This operation decreases the air intake slightly in FAN operation only.

NOTE

Notes on INTELLIGENT EYE operation

- Application range is as follows.

DAIKIN Cora FTKM20Q2VMA - Notes on INTELLIGENT EYE operation - 1

DAIKIN Cora FTKM20Q2VMA - Notes on INTELLIGENT EYE operation - 2

text_image Horizontal angle 110° (Top view) 55° 55° 7m

- While the air conditioner is in INTELLIGENT EYE operation, the louvres adjust the airflow direction if there are people in the sensing areas of the INTELLIGENT EYE so that the leftward or rightward air will not be directed to the people. If no people are detected in either area 1 or 2 for 20 minutes, the air conditioner switches to the energy-saving mode with the set temperature shifted by 2^ .

The air conditioner may switch to the energy-saving operation even if there are people in the areas.

This may occur depending on the clothes the people are wearing, if there is no movement of the people in the areas.

  • The airflow direction from the louvres will be leftward if there are people in both areas 1 and 2. The air will also flow left if there is a person right in front of the sensor as the sensor judges that there are people in both areas.
  • Due to the position of the sensor, people might be exposed to the airflow of the indoor unit if they are close to the front side of the indoor unit. If there are people close to the front side of the indoor unit or in both areas, it is recommended to use the COMFORT AIRFLOW and INTELLIGENT EYE operations simultaneously. Using both modes together, the air conditioner will not direct the airflow towards the people.
  • The sensor may not detect moving objects further than 7m away. (Please see the application range.)
  • Sensor detection sensitivity changes according to the indoor unit location, the speed of passers-by, temperature range, etc.
  • The sensor could also mistakenly detect pets, sunlight, fluttering curtains and light reflected off of mirrors as passers-by.
  • INTELLIGENT EYE operation will not switch on during POWERFUL operation.
  • NIGHT SET mode ▶Page 21 will not switch on during use of INTELLIGENT EYE operation.

DAIKIN Cora FTKM20Q2VMA - Notes on INTELLIGENT EYE operation - 3

POWERFUL Operation

DAIKIN Cora FTKM20Q2VMA - POWERFUL Operation - 1

text_image ON 27.0c MON 15:30 Powerful

POWERFUL operation quickly maximizes the cooling effect in any operation mode. In this mode, the air conditioner operates at maximum capacity.

To start POWERFUL operation

Press during operation.

• “ Is displayed on the LCD.
- POWERFUL operation ends in 20 minutes. Then the system automatically operates again with the previous settings which were used before POWERFUL operation.

To cancel POWERFUL operation

Press again.

• “ disappears from the LCD.

NOTE

Notes on POWERFUL operation

  • Pressing ⏻ causes the settings to be cancelled, and “💡” disappears from the LCD.
  • POWERFUL operation will not increase the capacity of the air conditioner if the air conditioner is already in operation with its maximum capacity demonstrated.
  • In COOL operation
    To maximize the cooling effect, the capacity of outdoor unit increases and the airflow rate becomes fixed at the maximum setting. The temperature and airflow settings cannot be changed.
  • In DRY operation
    The temperature setting is lowered by 2.5°C and the airflow rate is slightly increased.
  • In FAN operation
    The airflow rate is fixed at the maximum setting.

Regarding the combination of POWERFUL and other operations

POWERFUL + COMFORT AIRFLOWNot available*
POWERFUL + ECONO
POWERFUL + OUTDOOR UNIT QUIET

*Priority is given to the function of whichever button is pressed last.

DAIKIN Cora FTKM20Q2VMA - Notes on POWERFUL operation - 1

ECONO / OUTDOOR UNIT QUIET Operation

DAIKIN Cora FTKM20Q2VMA - ECONO / OUTDOOR UNIT QUIET Operation - 1

text_image 27.0°C MON 15:30 Ecoa/Outlet Timer

ECONO operation enables efficient operation by limiting the maximum power consumption.

This function is useful to prevent the circuit breaker from tripping when the unit operates alongside other appliances on the same circuit.

OUTDOOR UNIT QUIET operation lowers the noise level of the outdoor unit by changing the frequency and fan speed of the outdoor unit. This function is convenient during the night-time operation.

To start operation

Press Econo/Quiet and select the desired mode.

• Each time is pressed, a different setting option is displayed on the LCD.

DAIKIN Cora FTKM20Q2VMA - To start operation - 1

flowchart
graph LR
    A["ECONO OUTDOOR UNIT QUIET"] --> B["Combination"]
    B --> C["blank\nNo Setting"]

To cancel operation

Press Econo/Quiet until no icon is displayed.

NOTE

Notes on ECONO operation

  • Pressing ⏻ causes the settings to be cancelled, and “ ↘” disappears from the LCD.
  • If the power consumption level is already low, switching to ECONO operation will not reduce the power consumption.

Notes on OUTDOOR UNIT QUIET operation

  • Even if the operation is stopped by using the remote controller or the indoor unit ON/OFF switch when using OUTDOOR UNIT QUIET operation, "Cavill remain lit on the remote controller display.
  • OUTDOOR UNIT QUIET operation will not reduce the frequency nor fan speed if they already are operating at reduced levels.
  • This operation is performed with lower power and therefore may not provide a sufficient cooling effect.

Possible combinations of ECONO / OUTDOOR UNIT QUIET operation and basic operations

Operation mode
DRY COOLFAN
ECONO×
OUTDOOR UNIT QUIET××

DAIKIN Cora FTKM20Q2VMA - Notes on OUTDOOR UNIT QUIET operation - 1

ON/OFF TIMER Operation

DAIKIN Cora FTKM20Q2VMA - ON/OFF TIMER Operation - 1

text_image 27.0°C ON 6:00 Select Cancel On Timer

Timer functions are useful for automatically switching the air conditioner on or off at night or in the morning. You can also use the ON TIMER and OFF TIMER together.

To use ON TIMER with a 24 hour clock display (24 HOUR ON/OFF TIMER)

  • Check that the clock is correct.
    If not, set the clock to the present time. ▶ Page 10
    • To set the ON TIMER in an hours remaining display. ▶ Page 10

DAIKIN Cora FTKM20Q2VMA - To use ON TIMER with a 24 hour clock display (24 HOUR ON/OFF TIMER) - 1

text_image 1. Press On ON 6:00 "8:00" "ON"

- “①” and day of the week disappear from the LCD.

2. Press until the time setting reaches the point you like.

• Each pressing of either button increases or decreases the time setting by 10 minutes. Holding down either button changes the setting rapidly.

3. Press □ again.

  • "ONand setting time are displayed on the LCD.
    • The TIMER lamp lights orange.

DAIKIN Cora FTKM20Q2VMA - Press □ again. - 1

flowchart
graph TD
    A["Square"] --> B["Directional Arrow"]
    B --> C["Sun Icon"]
    C --> D["Circle Node"]
    D --> E["Circle Node"]
    E --> F["Circle Node"]
    F --> G["Circle Node"]
    G --> H["Circle Node"]
    H --> I["Circle Node"]
    I --> J["Circle Node"]
    J --> K["Circle Node"]
    K --> L["Circle Node"]
    L --> M["Circle Node"]
    M --> N["Circle Node"]
    N --> O["Circle Node"]
    O --> P["Circle Node"]
    P --> Q["Circle Node"]
    Q --> R["Circle Node"]
    R --> S["Circle Node"]
    S --> T["Circle Node"]
    T --> U["Circle Node"]
    U --> V["Circle Node"]
    V --> W["Circle Node"]
    W --> X["Circle Node"]
    X --> Y["Circle Node"]
    Y --> Z["Circle Node"]

Display

To cancel ON TIMER operation

DAIKIN Cora FTKM20Q2VMA - To cancel ON TIMER operation - 1

  • “ONand setting time disappear from the LCD.
  • “💡” and day of the week are displayed on the LCD.
    • The TIMER lamp goes off.

NOTE

Note on TIMER operation

- When TIMER is set, the present time is not displayed.

In the following cases, set the timer again.

• After the circuit breaker has turned off.
• After a power failure.
• After replacing the batteries in the remote controller.

DAIKIN Cora FTKM20Q2VMA - In the following cases, set the timer again. - 1

ON/OFF TIMER Operation

DAIKIN Cora FTKM20Q2VMA - ON/OFF TIMER Operation - 1

text_image 27.0°C OFF 0:00 Off Select Cancel Timer

To use OFF TIMER with a 24 hour clock display (24 HOUR ON/OFF TIMER)

  • Check that the clock is correct.
    If not, set the clock to the present time. ▶ Page 10
    • To set the ON TIMER in an hours remaining display. ▶ Page 10

1. Press Off

DAIKIN Cora FTKM20Q2VMA - Press Off - 1

"0.08 displayed on the LCD.

"OFF" blinks.

- “ ⊕” and day of the week disappear from the LCD.

2. Press until the time setting reaches the point you like.

- Each pressing of either button increases or decreases the timem setting by 10 minutes. Holding down either button changes the time setting rapidly.

3. Press again.

  • “OFF and setting time are displayed on the LCD.
    • The TIMER lamp lights orange.

DAIKIN Cora FTKM20Q2VMA - Press again. - 1

flowchart
graph TD
    A[" "] --> B[" "]
    B --> C[" "]
    C --> D[" "]
    D --> E[" "]
    E --> F[" "]
    F --> G[" "]
    G --> H[" "]
    H --> I[" "]
    I --> J[" "]
    J --> K[" "]
    K --> L[" "]
    L --> M[" "]
    M --> N[" "]
    N --> O[" "]
    O --> P[" "]
    P --> Q[" "]
    Q --> R[" "]
    R --> S[" "]
    S --> T[" "]
    T --> U[" "]
    U --> V[" "]
    V --> W[" "]
    W --> X[" "]
    X --> Y[" "]
    Y --> Z[" "]

Display

To cancel OFF TIMER operation

Press Cancel

  • “OFF and setting time disappear from the LCD.
  • “ ⊕” and day of the week are displayed on the LCD.
    • The TIMER lamp goes off.

To combine ON TIMER and OFF TIMER

- A sample setting for combining the 2 timers is shown below.

DAIKIN Cora FTKM20Q2VMA - To combine ON TIMER and OFF TIMER - 1

text_image (Example) Present time: 23:00 (The unit operating) OFF TIMER at 0:00 ON TIMER at 14:00) Combined OFF 0:00 ON 14:00

NOTE

NIGHT SET mode

- When the OFF TIMER is set, the air conditioner automatically adjusts the temperature setting (0.5°C up in COOL) to prevent excessive cooling during sleeping hours.

DAIKIN Cora FTKM20Q2VMA - NIGHT SET mode - 1

text_image 27.8°C ON ihr Select On Cancel Timer

To use the ON/OFF TIMER with an hours remaining display (COUNT UP-DOWN ON/OFF TIMER)

- Check that the clock is correct.

If not, set the clock to the present time. ▶ Page 10

DAIKIN Cora FTKM20Q2VMA - Press and hold on or for about 5 seconds, when signal indicator (▲) blink, release your finger from the button. - 1

For ON TIMER

"Ibr" is displayed on the LCD.

"ON" blinks.

For OFF TIMER

"Ibr" is displayed on the LCD.

"OFF" blinks.

- “ ⏻ ” and day of the week disappear from the LCD.

2. Press until the time setting reaches the point you like.

• Each pressing of the button increases or decreases the time setting by 1 hour.

• The time can be set between 1 and 12 hours.

3. Press on or again.

  • “ON” or “OFF”, and setting time are displayed on the LCD.
    • The TIMER lamp lights orange.

DAIKIN Cora FTKM20Q2VMA - Press on or again. - 1
Display

  • To change the display mode from COUNT UP-DOWN ON/OFF TIMER to 24 HOUR ON/OFF TIMER, repeat STEP 1, and continue from STEP 2 of "24 HOUR ON/OFF TIMER". ▶ Page 20.21
  • Timer display mode cannot be changed while "ON" or "OFF" are blinking. Press ☐ or ☐ to stop the blinking.

Combining display modes

- Different display modes (24 HOUR ON/OFF TIMER and COUNT UP-DOWN ON/OFF TIMER) can be used for the ON TIMER and OFF TIMER simultaneously.

(Example)-

Present time: 22:00 [unit is in operation] OFF TIMER at 1:00 (3 hours after present time) ON TIMER at 6:00 (8 hours after present time) Combined

DAIKIN Cora FTKM20Q2VMA - Combining display modes - 1

text_image OFF 3hr ON 6:00 OFF 1:00 ON 8hr OFF 3hr ON 8hr

NOTE

Notes on COUNT UP-DOWN ON/OFF TIMER

- After setting, the time displayed on the LCD will automatically count down by 1 hour for every 1 hour that passes. For example, if the OFF TIMER is set to 3 hours, the display will change as follows: 3hr 2hr 1hr blank (OFF)

Switching between ON/OFF TIMER display modes (24 hour clock and hours remaining display)

- When change display mode (from 24 HOUR ON/OFF TIMER to COUNT UP-DOWN ON/OFF TIMER or from COUNT UP-DOWN ON/OFF TIMER to 24 HOUR ON/OFF TIMER), cancel timer. So, to use timer, set timer again.

DAIKIN Cora FTKM20Q2VMA - Switching between ON/OFF TIMER display modes (24 hour clock and hours remaining display) - 1

WEEKLY TIMER Operation

Up to 4 timer settings can be saved for each day of the week. This is convenient to adapt the WEEKLY TIMER to your family's life style.

Setting example of the WEEKLY TIMER

The same timer settings are used from Monday through Friday, while different timer settings are used for the weekend.

[Monday]Make timer settings for programmes 1-4. ▶Page 24Programme 1 Programme 2 Programme 3 Programme 4DAIKIN Cora FTKM20Q2VMA - Setting example of the WEEKLY TIMER - 1 DAIKIN Cora FTKM20Q2VMA - Setting example of the WEEKLY TIMER - 2 DAIKIN Cora FTKM20Q2VMA - Setting example of the WEEKLY TIMER - 3 DAIKIN Cora FTKM20Q2VMA - Setting example of the WEEKLY TIMER - 4
[Tuesday] to [Friday]Use the copy mode to make settings for Tuesday to Friday, because these settings are the same as those for Monday. ▶Page 26Programme 1 Programme 2 Programme 3 Programme 4DAIKIN Cora FTKM20Q2VMA - Setting example of the WEEKLY TIMER - 5
[Saturday]No timer settings
[Sunday]Make timer settings for programmes 1-4. ▶Page 24Programme 1 Programme 2 Programme 3 Programme 4DAIKIN Cora FTKM20Q2VMA - Setting example of the WEEKLY TIMER - 6
  • Up to 4 reservations per day and 28 reservations per week can be set using the WEEKLY TIMER. The effective use of the copy mode simplifies timer programming.
  • The use of ON-ON-ON-ON settings, for example, makes it possible to schedule operating mode and set temperature changes. Furthermore, by using OFF-OFF-OFF-OFF settings, only the turn off time of each day can be set. This will turn off the air conditioner automatically if you forget to turn it off.

DAIKIN Cora FTKM20Q2VMA - Setting example of the WEEKLY TIMER - 7

text_image 27.0°C ON 6:00 MON 25.0°C Select Next Timer

To use WEEKLY TIMER operation

Setting mode

• Make sure the day of the week and time are set. If not, set the day of the week and time. ▶ Page 10

Programme 1 Programme 2 Programme 3 Programme 4
DAIKIN Cora FTKM20Q2VMA - Setting mode - 1

text_image [Monday] ON OFF ON OFF 25.0°C 27.0°C 6:00 8:30 17:30 22:00

Setting Displays
DAIKIN Cora FTKM20Q2VMA - Setting mode - 2

flowchart
graph LR
    A["MON"] --> B["ON/OFF"]
    B --> C["6:00"]
    C --> D["Temperature"]

1. Press

  • The day of the week and the reservation number of the current day will be displayed.
  • 1 to 4 settings can be made per day.

2. Press Select to select the desired day of the week and reservation number.

- Pressing □ changes the reservation number and the day of the week.

3. Press Next .

• The day of the week and reservation number will be set.
- “WEEKLY” and “ON” blink.

4. Press Select to select the desired mode.

- Pressing ▲ changes the "ON" or "OFF" setting in sequence.

DAIKIN Cora FTKM20Q2VMA - Press Select to select the desired mode. - 1

flowchart
graph LR
    A["ON"] --> B["OFF"]
    B --> C["blank"]
    D["ON TIMER"] --> A
    E["OFF TIMER"] --> B
    F["No Setting"] --> C
  • In case the reservation has already been set, selecting "blank" deletes the reservation.
  • Proceed to STEP 9 if "blank" is selected.
  • To return to the day of the week and reservation number setting, press Back.

5. Press Next .

• The ON/OFF TIMER mode will be set.
• “WEEKLY” and the time blink.

DAIKIN Cora FTKM20Q2VMA - Press Next . - 1

WEEKLY TIMER Operation

DAIKIN Cora FTKM20Q2VMA - WEEKLY TIMER Operation - 1

text_image 27.0°C ON TUE 6:00 25.0°C Back Select Next Timer

6. Press to select the desired time.

  • The time can be set between 0:00 and 23:50 in 10-minute intervals.
  • To return to the ON/OFF TIMER mode setting, press Back
    • Proceed to STEP 9 when setting the OFF TIMER.

7. Press Next

• The time will be set.
• “ ⏻ WEEKLY ” and the temperature blink.

8. Press to select the desired temperature.

• The temperature can be set between 10.0°C and 32.0°C.
COOL or AUTO: The unit operates at 18.0°C even if it is set to 10.0°C to 17.0°C. ▶ Page 12 HEAT or AUTO : The unit operates at 30.0°C even if it is set to 31.0°C to 32.0°C. ▶ Page 12
• To return to the time setting, press Back.
- The set temperature is only displayed when the mode setting is on.

9. Press Next .

  • The temperature will be set and go to the next reservation setting.
  • The temperature is set while in ON TIMER operation, and the time is set while in OFF TIMER operation.
    • The next reservation screen will appear.
    • To continue further settings, repeat the procedure from STEP 4.

10. Press to complete the setting.

  • Be sure to direct the remote controller toward the indoor unit and check for a receiving tone and blinking of the OPERATION lamp.
  • “WEEKLY” is displayed on the LCD and WEEKLY TIMER operation is activated.
    • The TIMER lamp lights orange.

DAIKIN Cora FTKM20Q2VMA - Press to complete the setting. - 1

flowchart
graph TD
    A["Start"] --> B{Decision}
    B -->|Yes| C["Node 1"]
    B -->|No| D["Node 2"]
    C --> E["Person Icon"]
    D --> F["Circle Node"]
    E --> G["Circle Node"]
    F --> H["Circle Node"]

Display

- A reservation made once can be easily copied and the same settings used for another day of the week. Refer to Copy mode ▶ Page 26

NOTE

Notes on WEEKLY TIMER operation

  • Do not forget to set the clock on the remote controller first. ▶ Page 10
  • The day of the week, ON/OFF TIMER mode, time and set temperature (only for ON TIMER mode) can be set with the WEEKLY TIMER. Other settings for the ON TIMER are based on the settings just before the operation.
  • WEEKLY TIMER and ON/OFF TIMER operation cannot be used at the same time. The ON/OFF TIMER operation has priority if it is set while WEEKLY TIMER is still active. The WEEKLY TIMER will enter the standby state, and “WEEKLY” will disappear from the LCD. When the ON/OFF TIMER is up, the WEEKLY TIMER will automatically become active.
  • Only the time and set temperature with the WEEKLY TIMER are sent with the ☐. Set the WEEKLY TIMER only after setting the operation mode, the airflow rate and the airflow direction ahead of time.
  • Turning off the circuit breaker, power failure, and other similar events will render operation of the indoor unit's internal clock inaccurate. Reset the clock. ▶Page 10
  • Back can be used only for the time and temperature settings. It cannot be used to go back to the reservation number.

DAIKIN Cora FTKM20Q2VMA - Notes on WEEKLY TIMER operation - 1

text_image WEDNES 27.0°C ON TUE 8:00 25.0°C Copy Select Timer

Copy mode

- A reservation made once can be copied to another day of the week. The whole reservation of the selected day of the week will be copied.

DAIKIN Cora FTKM20Q2VMA - Copy mode - 1

text_image Programme 1 Programme 2 Programme 3 Programme 4 ON OFF ON OFF [Monday] 25.0°C 27.0°C 6:00 8:30 17:30 22:00 COPY

DAIKIN Cora FTKM20Q2VMA - Copy mode - 2

text_image Programme 1 Programme 2 Programme 3 Programme 4 [Tuesday] ON OFF ON OFF to [Friday] 25.0°C 27.0°C 6:00 8:30 17:30 22:00

DAIKIN Cora FTKM20Q2VMA - Copy mode - 3

flowchart
graph LR
    A["Setting Displays"] --> B["Confirmation"]
    B --> C["CopyPaste Normal"]
    C --> D["Final confirmation"]
  1. Press
  2. Press Select to confirm the day of the week to be copied.
  3. Press Copy

- The whole reservation of the selected day of the week will be copied.

  1. Press Select to select the destination day of the week.
  2. Press Copy

  3. The reservation will be copied to the selected day of the week. The whole reservation of the selected day of the week will be copied.
    • To continue copying the settings to other days of the week, repeat STEP 4 and STEP 5.

  4. Press ☐ to complete the setting.

- “WEEKLY” is displayed on the LCD and WEEKLY TIMER operation is activated.

NOTE

Note on COPY MODE

- The entire reservation of the source day of the week is copied in the copy mode.

In the case of making a reservation change for any day of the week individually after copying the content of weekly reservations, press and change the settings in the steps of Setting mode. ▶ Page 24

DAIKIN Cora FTKM20Q2VMA - Note on COPY MODE - 1

WEEKLY TIMER Operation

DAIKIN Cora FTKM20Q2VMA - WEEKLY TIMER Operation - 1

text_image ON 27.0°C ON TUE 6:00 25.0°C Weekly Select Next Timer

Confirming a reservation

• The reservation can be confirmed.

DAIKIN Cora FTKM20Q2VMA - Confirming a reservation - 1

text_image Setting Displays TUE 15:30 Normal ON 6:00 TUE 25.0c Confirmation

1. Press

- The day of the week and the reservation number of the current day will be displayed.

2. Press to select the day of the week and the reservation number to be confirmed.

  • Pressing Select displays the reservation details.
  • To change the confirmed reserved settings, select the reservation number and press Next. The mode is switched to setting mode. Proceed to Setting mode STEP 4. ▶ Page 24

3. Press to exit the confirmation mode.

  • “WEEKLY” is displayed on the LCD and WEEKLY TIMER operation is activated.
    • The TIMER lamp lights orange.

DAIKIN Cora FTKM20Q2VMA - Press to exit the confirmation mode. - 1

flowchart
graph TD
    A["Start"] --> B{Decision}
    B -->|Yes| C["User Icon"]
    B -->|No| D["Process Step"]
    D --> E["End"]

Display

To deactivate WEEKLY TIMER operation

DAIKIN Cora FTKM20Q2VMA - To deactivate WEEKLY TIMER operation - 1

Weekly sser while “ ⚙ WEEKLY ” is displayed on the LCD.

  • “ Ⓧ WEEKLY ” disappears from the LCD.
    • The TIMER lamp goes off.
    • To reactivate the WEEKLY TIMER operation, press □ again.
  • If a reservation deactivated with □ is activated once again, the last reservation mode will be used.

NOTE

- If not all the reservation settings are reflected, deactivate the WEEKLY TIMER operation once. Then press ☐ again to reactivate the WEEKLY TIMER operation.

DAIKIN Cora FTKM20Q2VMA - NOTE - 1

text_image ON 27.0°C A OFF/WHM ON 6:00 TUE 25.0°C Weekly Next Select Timer

To delete reservations

An individual reservation

1. Press

- The day of the week and the reservation number will be displayed.

2. Press to select the day of the week and the reservation number to be deleted.

3. Press Next

- “ WEEKLY ” and “ ON ” or “ OFF ” blink.

4. Press until no icon is displayed.

- Pressing changes the ON/OFF TIMER mode in sequence.

- Selecting "blank" will cancel any reservation you may have.

DAIKIN Cora FTKM20Q2VMA - Press until no icon is displayed. - 1

flowchart
graph LR
    A["ON"] --> B["OFF"]
    B --> C["blank"]
    D["ON TIMEROFF TIMER"] --> E["No Setting"]

5. Press Next .

- The selected reservation will be deleted.

6. Press

- If there are still other reservations, WEEKLY TIMER operation will be activated.

Reservations for each day of the week

  • This function can be used for deleting reservations for each day of the week.
  • It can be used while confirming or setting reservations.

1. Press Select to select the day of the week to be deleted.

2. Hold for about 5 seconds.

- The reservation of the selected day of the week will be deleted.

All reservations

Hold Weekly for about 5 seconds with the normal display.

  • Be sure to direct the remote controller toward the indoor unit and check for a receiving tone.
  • This operation cannot be used for the WEEKLY TIMER setting display.
  • All reservations will be deleted.

Care and Cleaning

DAIKIN Cora FTKM20Q2VMA - Care and Cleaning - 1

CAUTION

  • Before cleaning, be sure to stop the operation and turn off the circuit breaker.
  • Do not touch the aluminum fins of the indoor unit. If you touch those parts, this may cause an injury.

DAIKIN Cora FTKM20Q2VMA - CAUTION - 1

text_image ■ Quick reference Cleaning parts Front panel • Wipe it with a soft damp cloth. If dirty ▶ Page 30 Air filter • Vacuum dust or wash the filter. Once every 2 weeks ▶ Page 31 Indoor unit and Remote controller • Wipe them with a soft cloth. If dirty Deodorizing filter (enzyme blue) To purchase the filters (Table 1) or to purchase the another type, contact the dealer where you bought the air conditioner. The method of cleaning and replacement of the filters may differ depending on the model. Refer to the label attached to the separately sold filters themselves. Table 1 Item Part No. Air quality filter (enzyme blue with PM 2.5) - without frame (set of 2) BAFP094A43 Deodorizing filter (enzyme blue) - without frame (set of 2) BAFP094A41 Dust collection filter (PM 2.5) - without frame (set of 2) BAFP046A41 Titanium apatite deodorizing filter - without frame (set of 2) KAF970A46 Deodorizing filter (enzyme blue).Titanium apatite

Deodorizing filter (enzyme blue), Titanium apatite deodorizing filter.

• Vacuum dust or replace the filter. [Cleaning] [Replacement]

Once every 6 months

Once every 3 years

▶ Page 32

Air quality filter (enzyme blue with PM 2.5), Dust collection filter (PM 2.5)

- No cleaning is required. Please replace the filter every 6 months. ▶ Page 28

NOTE

For cleaning, do not use any of the following:

• Water hotter than 40.0°C
• Volatile liquid such as benzene, petrol and thinner
- Polishing compounds
- Rough materials such as a scrubbing brush

DAIKIN Cora FTKM20Q2VMA - NOTE - 1

natural_image Illustration of a kettle, a brush, and a bottle (no text or symbols)

DAIKIN Cora FTKM20Q2VMA - NOTE - 2

CAUTION

  • When removing or attaching the front panel, stand on a solid, stable base and take care not to fall.
  • When removing or attaching the front panel, support the panel securely with your hand to prevent it from falling.

■ Front panel

1. Open the front panel.

- Hold the front panel by the panel tabs on the 2 sides and open it.

DAIKIN Cora FTKM20Q2VMA - Open the front panel. - 1

text_image Panel tab

2. Remove the front panel.

- Slide the front panel to either the left or right and pull it toward you. This will disconnect the front panel shaft on one side.

DAIKIN Cora FTKM20Q2VMA - Remove the front panel. - 1

text_image 2) Pull 1) Slide Front panel shaft 2) Pull 1) Slide

- Disconnect the front panel shaft on the other side in the same manner.

3. Clean the front panel.

  • Wipe it with a soft damp cloth.
  • Only neutral detergent may be used.
  • In case of washing the panel with water, wipe it with a dry soft cloth, and let it dry in the shade after washing.

4. Attach the front panel.

- Align the front panel shaft on the left and right of the front panel with the grooves, then push them all the way in.

DAIKIN Cora FTKM20Q2VMA - Attach the front panel. - 1

text_image Front panel shaft Groove

5. Close the front panel slowly.

- Press the front panel at both sides and thecentre.

DAIKIN Cora FTKM20Q2VMA - Close the front panel slowly. - 1

natural_image Illustration of a car air conditioner unit with three arrows indicating airflow direction (no text or symbols)

- Make sure that the front panel is securely fixed.

Care and Cleaning

■ Air filter

1. Open the front panel. ▶ Page 30

2. Pull out the air filters.

- Push the filter tab at the centre of each air filter a little upwards, then pull it down.

DAIKIN Cora FTKM20Q2VMA - Pull out the air filters. - 1

text_image 1) Push 2) Pull down

3. Wash the air filters with water or clean them with a vacuum cleaner.

- It is recommended to clean the air filters every 2 weeks.

DAIKIN Cora FTKM20Q2VMA - Wash the air filters with water or clean them with a vacuum cleaner. - 1

natural_image Illustration of hands holding a grid-based panel with scissors, no text or symbols present

If the dust does not come off easily

- Wash the air filters with neutral detergent thinned with lukewarm water, then let them dry in the shade.

DAIKIN Cora FTKM20Q2VMA - If the dust does not come off easily - 1

natural_image Simple line drawing of a basin with a rectangular object on top (no text or symbols)
  1. Set the filters as they were.
  2. Close the front panel slowly.

■ Filter (small)

* For the applicable filter type, please refer to ▶ Page 30.

Attaching

  1. Open the front panel and pull out the air filters. ▶ Page 31

  2. Insert the filter.

- Check that the filters are inserted securely under the tabs.

DAIKIN Cora FTKM20Q2VMA - Attaching - 1

text_image Filter (small) Tab

Cleaning and Replacement

  1. Open the front panel and pull out the air filters. ▶ Page 31

  2. Take off the filter.

- Remove the filters from the tabs.

DAIKIN Cora FTKM20Q2VMA - Cleaning and Replacement - 1

text_image Filter (small) Tab

NOTE

• Operation with dirty filters:
- cannot deodorise the air,
- cannot clean the air,
– results in poor cooling,
-may cause odour.
- Dispose of old filters as non-flammable waste.

  1. Clean or replace.

[Cleaning]

Deodorizing filter (enzyme blue) : Blue / Titanium apatite deodorizing filter : Blue-Black

3-1 Vacuum dust, and soak in lukewarm water or water for about 10 to 15 minutes if very dirty.
3-2 After washing, shake off remaining water and let them dry in the shade.

- This filter can be renewed by washing it with water once every 6 months and we recommend replacing it once every 3 years.

- Do not wiring out the filter when removing water from it.

Air quality filter (enzyme blue with PM 2.5) : Blue-White / Dust collection filter (PM 2.5) : White

- Do not wash the filters as this will reduce their efficiency.

- It is recommended to replace it once every 6 months.

[Replacement]

Remove each filter from the filter frame and prepare a new one.

- When attaching the filter, check that the filter is properly set in the tabs.

  1. Set the filters as they were and close the front panel.

- Press the front panel at both sides and the center.

Care and Cleaning

■ Prior to a long period of non-use

1. Operate the FAN mode for several hours on a fine day to dry out the inside.

  • Press Mode and select "♣".
  • Press On/Off and start the operation.

2. After operation stops, turn off the circuit breaker for the room air conditioner.

3. Take out the batteries from the remote controller.

■ We recommend periodical maintenance

  • In certain operating conditions, the inside of the air conditioner may get foul after several seasons of use, resulting in poor performance. It is recommended to have periodical maintenance by a specialist in addition to regular cleaning by the user.
  • For specialist maintenance, please contact the dealer where you bought the air conditioner.
  • The maintenance cost must be borne by the user.

FAQ

Indoor unit

The flaps do not start swinging immediately.

- The air conditioner is adjusting the position of the laps. The flaps start moving soon.

Operation does not start soon.

■ When was pressed soon after operation was stopped.
■ When the mode was reselected.
• This is to protect the air conditioner. You should wait for about 3 minutes.

DAIKIN Cora FTKM20Q2VMA - Operation does not start soon. - 1

natural_image Line drawing of a wall-mounted air conditioner unit (no text or symbols)

Different sounds are heard.

■ A sound like flowing water

  • This sound is generated because the refrigerant in the air conditioner is flowing.
  • This is a pumping sound of the water in the air conditioner and can be heard when the water is pumped out from the air conditioner during COOL or DRY operation.
  • The refrigerant flows in the air conditioner even if the air conditioner is not working when the indoor units in other rooms are in operation.

■ Blowing sound

- This sound is generated when the flows of the refrigerant in the air conditioner is switched over.

■ Ticking sound

- This sound is generated when the cabinet and frame of the air conditioner slightly expand or shrink as a result of temperature changes.

■ Whistling sound

- This sound is generated when refrigerant flows during defrosting operation.

■ Clicking sound during operation or idle time

- This sound is generated when the refrigerant control valves or the electrical parts operate.

■ Clopping sound

- This sound is heard from the inside of the air conditioner when the exhaust fan is activated while the room doors are closed. Open the window or turn off the exhaust fan.

■ Rotating machinery causes sound

  • Sound is heard when the vertical swing flaps and the horizontal swing flaps move.
  • When the air conditioner is operating in a quiet environment and the airflow rate of the indoor unit is set to Quiet Mode or Low Mode, the motion of the swing flaps may cause sound.

Outdoor unit

The outdoor unit emits water.

In COOL or DRY operation
- Moisture in the air condenses into water on the cool surface of the outdoor unit piping and drips.

DAIKIN Cora FTKM20Q2VMA - The outdoor unit emits water. - 1

natural_image Line drawing of a large air conditioning unit with a circular vent grille and mounting base (no text or symbols)

*The appearance of the outdoor unit may differ from some models.

Troubleshooting

Before making an inquiry or a request for repair, please check the following.

If the problem persists, consult your dealer.

DAIKIN Cora FTKM20Q2VMA - Troubleshooting - 1

Not trouble

These cases are not troubles.

DAIKIN Cora FTKM20Q2VMA - Not trouble - 1

Check

Please check again before requesting repairs.

The air conditioner does not operate

Case Description / what to check
OPERATION lamp is off.Has the circuit breaker been tripped or the fuse blown?Is there a power failure?Are batteries set in the remote controller?
OPERATION lamp is blinking.Turn off the power with the circuit breaker and restart operation with the remote controller.If the OPERATION lamp is still blinking, check the error code and consult your dealer.

The air conditioner suddenly stops operating

Case Description / what to check
OPERATION lamp is on.To protect the system, the air conditioner may stop operating after sudden large voltage fluctuations. It automatically resumes operation in about 3 minutes.
OPERATION lamp is blinking.Is there anything blocking the air inlet or air outlet of the indoor unit or outdoor unit? Stop operation and after turning off the circuit breaker, remove the obstruction. Then restart operation with the remote controller. If the OPERATION lamp is still blinking, check the error code and consult your dealer. ▶ Page 38

The air conditioner does not stop operating

Case Description / what to check
The air conditioner continues operating even after operation is stopped.☑ Immediately after the air conditioner is stopped• The outdoor unit fan continues rotating for about another 1 minute to protect the system.• While the air conditioner is not in operation• When the outdoor temperature is high, the outdoor unit fan may start rotating to protect the syste.

The room does not cool down

Case Description / what to check
Air does not come out.When the air conditioner operates immediately after the circuit breaker is turned onThe air conditioner is preparing to operate. Wait for about 3 to 15 minutes.
Air does not come out / Air comes out.Is the airflow rate setting appropriate?Is the airflow rate setting low, such as “Indoor unit quiet” or “1”? Increase the airflow rate setting.Is the set temperature appropriate?Is the adjustment of the airflow direction appropriate?
Air comes out.Is there any furniture directly under or beside the indoor unit?Is the air conditioner in ECONO operation or OUTDOOR UNIT QUIET operation?Are the air filters dirty?Is there anything blocking the air inlet or air outlet of the indoor unit or outdoor unit?Is a window or door open?Is an exhaust fan turning?

Mist comes out

Case Description / what to check
Mist comes out of the indoor unit.This happens when the air in the room is cooled into mist by the cold airflow during COOL or other operation.

Remote controller

Case Description / what to check
The unit does not receive signals from the remote controller or has a limited operating range.The batteries may be exhausted.Replace both batteries with new dry batteries AAA.LR03 (alkaline).For details, refer to “Preparation Before Operation”. ▶Page 9Signal communication may be disabled if an electronic-starter-type fluorescent lamp (such as inverter-type lamps) is in the room. Consult your dealer if that is the case.The remote controller may not function correctly if the transmitter is exposed to direct sunlight.
LCD is faint, is not working, or the display is erratic.The batteries may be exhausted.Replace both batteries with new dry batteries AAA.LR03 (alkaline).For details, refer to “Preparation Before Operation”. ▶Page 9
Other electric devices start operating.If the remote controller activates other electric devices, move them away or consult your dealer.

Air has an odour

Case Description / what to check
The air conditioner gives off an odour.The room odour absorbed in the unit is discharged with the airflow.We recommend you to have the indoor unit cleaned. Please consult your dealer.

Others

Case Description / what to check
The air conditioner suddenly starts behaving strangely during operation.The air conditioner may malfunction due to lightning or radio.If the air conditioner malfunctions, turn off the power with the circuit breaker and restart the operation with the remote controller.
The ON/OFF TIMER does not operate according to the settings.Check if the ON/OFF TIMER and the WEEKLY TIMER are set to the same time.Change or deactivate the settings in the WEEKLY TIMER. ▶ Page 23

Notes on the operating conditions

  • If operation continues under any conditions other than those listed in the table,
    – A safety device may activate to stop the operation.
  • Dew may form on the indoor unit and drip from it when COOL or DRY operation is selected.
ModeOperating conditions
DRYOutdoor temperature : -10.0-46.0°CIndoor temperature : 18.0-32.0°CIndoor humidity : 80% max.
COOLOutdoor temperature : -10.0-46.0°CIndoor temperature : 18.0-32.0°CIndoor humidity : 80% max.

Troubleshooting

■ Call your dealer immediately

DAIKIN Cora FTKM20Q2VMA - ■ Call your dealer immediately - 1

WARNING

When an abnormality (such as a burning smell) occurs, stop operation and turn off the circuit breaker.

  • Continued operation in an abnormal condition may result in troubles, electric shocks or fire.
  • Consult the dealer where you bought the air conditioner.

Do not attempt to repair or modify the air conditioner by yourself.

  • Incorrect work may result in electric shocks or fire.
  • Consult the dealer where you bought the air conditioner.

If one of the following symptoms takes place, call your dealer immediately.

  • The power cord is abnormally hot or damaged.
  • An abnormal sound is heard during operation.
  • The circuit breaker, a fuse, or the earth leakage circuit breaker cuts off the operation frequently.
  • A switch or a button often fails to work properly.
    • There is a burning smell.
    • Water leaks from the indoor unit.

Turn off the circuit breaker and call your dealer.

DAIKIN Cora FTKM20Q2VMA - WARNING - 1

■ After a power failure
- The air conditioner automatically resumes operation in about 3 minutes. You should just wait for a while.
Lightning
- If there is a risk lightning could strike in the neighbourhood, stop operation and turn off the circuit breaker to protect the system.

■ Disposal requirements

- Dismantling of the unit, handling of the refrigerant, oil and other parts, should be done in accordance with the relevant local and national regulations.

DAIKIN Cora FTKM20Q2VMA - ■ Disposal requirements - 1

text_image ON 88 STD ON OFF ON MONTLEWED THUFRI SATSUN ON 38:88 ON 38:88 Cancel Timer

■ Fault diagnosis by remote controller

- The remote controller can receive relevant error codes from the indoor unit.

  1. When is held down for about 5 seconds, "00 blinks in the temperature display section.

  2. Press repeatedly until a continuous beep is produced.

- The code indication changes as shown below, and notifies you with a long beep.

CODE MEANING
SYSTEM00NORMAL
UAINDOOROUTDOOR UNIT COMBINATION FAULT
U0REFRIGERANT SHORTAGE
U2DROP VOLTAGE OR MAIN CIRCUIT OVERVOLTAGE
U4FAILURE OF TRANSMISSION (BETWEEN INDOOR UNIT AND OUTDOOR UNIT)
INDOOR UNITA1INDOORPCB DEFECTIVENESS
A5HIGH PRESSURE CONTROL OR FREEZE-UP PROTECTOR
A6FAN MOTOR FAULT
C4FAULTY HEAT EXCHANGER TEMPERATURE SENSOR
C9FAULTY SUCTION AIR TEMPERATURE SENSOR
OUTDOOR UNITEACOOLING-HEATING SWITCHING ERROR
E1CIRCUIT BOARD FAULT
E5OL STARTED
E6FAULTYCOMPRESSOR START UP
E7DC FAN MOTOR FAULT
E8OVERCURRENT INPUT
F3HIGH TEMPERATURE DISCHARGE PIPE CONTROL
F6HIGH PRESSURE CONTROL (IN COOLING)
H0 SENSOR FAULT
H6OPERATION HALT DUE TO FAULTY POSITION DETECTION SENSOR
H8 DC CURRENT SENSOR FAULT
H9FAULTY SUCTION AIR TEMPERATURE SENSOR
J3FAULTY DISCHARGE PIPE TEMPERATURE SENSOR
J6FAULTY HEAT EXCHANGER TEMPERATURE SENSOR
L3ELECTRICAL PARTS HEAT FAULT
L4HIGH TEMPERATURE AT INVERTER CIRCUIT HEATSINK
L5OUTPUT OVERCURRENT
P4FAULTY INVERTER CIRCUIT HEATSINK TEMPERATURE SENSOR

NOTE

  • A short beep and 2 consecutive beeps indicate non-corresponding codes.
  • To cancel the code display, hold □ down for about 5 seconds. The code display also clears if no button is pressed for 1 minute.

Quick Reference

DAIKIN Cora FTKM20Q2VMA - Quick Reference - 1

flowchart
graph TD
    A["Air Condition"] --> B["On/Off Fan"]
    B --> C{Temperature Control}
    C --> D["Mode: 27.0°C"]
    C --> E["Switch: 15:30"]
    D --> F["ON: 18°C → 32°C"]
    E --> G["Mode: 18°C → 32°C"]
    F --> H["Weather Change Icon"]
    G --> I["Weather Change Icon"]
    H --> J["Refrigeration Mode"]
    I --> K["Refrigeration Mode"]
    J --> L["Refrigeration Mode"]
    K --> M["Refrigeration Mode"]
    L --> N["Refrigeration Mode"]
    M --> O["Refrigeration Mode"]
    N --> P["Refrigeration Mode"]
    O --> Q["Refrigeration Mode"]
    P --> R["Refrigeration Mode"]
    Q --> S["Refrigeration Mode"]
    R --> T["Refrigeration Mode"]
    S --> U["Refrigeration Mode"]
    T --> V["Refrigeration Mode"]
    U --> W["Refrigeration Mode"]
    V --> X["Refrigeration Mode"]
    W --> Y["Refrigeration Mode"]
    X --> Z["Refrigeration Mode"]

DAIKIN INDUSTRIES, LTD.

Head office:

Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,

Kita-ku, Osaka, 530-8323 Japan

Tokyo office:

JR Shinagawa East Bldg., 2-18-1, Konan,

Minato-ku, Tokyo, 108-0075 Japan

https://www.daikin.com

DAIKIN Cora FTKM20Q2VMA - DAIKIN INDUSTRIES, LTD. - 1

The two-dimensional bar code is a manufacturing code.

OPERATION MANUAL

DAIKIN ROOM AIR CONDITIONER

DAIKIN Cora FTKM20Q2VMA - OPERATION MANUAL - 1

natural_image Line drawing of a single air conditioner unit with no text or symbols

MODELS

FTKM50Q2VMA
FTKM60Q2VMA
FTKM71Q2VMA

DAIKIN Cora FTKM20Q2VMA - MODELS - 1

natural_image Illustration of a city skyline above Earth with continents and oceans (no text or symbols)

Features

Enhanced comfort and energy savings

DAIKIN Cora FTKM20Q2VMA - Enhanced comfort and energy savings - 1

INTELLIGENT EYE

The INTELLIGENT EYE sensor detects human movement in a room for more than 20 minutes, the operation automatically changes to energy saving operation. ▶ Page 16

DAIKIN Cora FTKM20Q2VMA - INTELLIGENT EYE - 1

WEEKLY TIMER

Up to 4 timer settings can be saved for each day of the week according to your family's life style. The WEEKLY TIMER allows you to set on/off times and the desired temperature. ▶ Page 23

Other functions

DAIKIN Cora FTKM20Q2VMA - Other functions - 1

COMFORT AIRFLOW OUTDOOR UNIT QUIET

The airflow direction is upward while in COOL operation, and downward while in HEAT operation. This function prevents cold or warm air from blowing directly on your body. ▶ Page 15

DAIKIN Cora FTKM20Q2VMA - COMFORT AIRFLOW OUTDOOR UNIT QUIET - 1

OUTDOOR UNIT QUIET operation assures a low noise level of the outdoor unit. This function is useful to maintain a quiet neighbourhood.

Page 19

DAIKIN Cora FTKM20Q2VMA - COMFORT AIRFLOW OUTDOOR UNIT QUIET - 2

natural_image Modern minimalist living room interior with white sofa, wall-mounted air conditioner unit, and potted plant (no text or symbols)

DAIKIN Cora FTKM20Q2VMA - COMFORT AIRFLOW OUTDOOR UNIT QUIET - 3

ECONO

This function enables efficient operation by limiting the maximum power consumption. It is useful when using the air conditioner and other electrical devices simultaneously on a shared electrical circuit. Page 19

Contents

Read Before Operation

Safety Precautions 3

Names of Parts 5

Preparation Before Operation 9

Basic Operation

DAIKIN Cora FTKM20Q2VMA - Basic Operation - 1

DRY · COOL · FAN Operation...... 11

DAIKIN Cora FTKM20Q2VMA - Basic Operation - 2

Adjusting the Airflow Direction...... 13

DAIKIN Cora FTKM20Q2VMA - Basic Operation - 3

Adjusting the Airflow Rate...... 14

Useful Functions

DAIKIN Cora FTKM20Q2VMA - Useful Functions - 1

COMFORT AIRFLOW Operation.....15

DAIKIN Cora FTKM20Q2VMA - Useful Functions - 2

INTELLIGENT EYE Operation...... 16

DAIKIN Cora FTKM20Q2VMA - Useful Functions - 3

POWERFUL Operation.... 18

DAIKIN Cora FTKM20Q2VMA - Useful Functions - 4

ECONO/OUTDOOR UNIT QUIET Operation.... 19

TIMER Operation

DAIKIN Cora FTKM20Q2VMA - TIMER Operation - 1

ON/OFF TIMER Operation...... 20

DAIKIN Cora FTKM20Q2VMA - TIMER Operation - 2

WEEKLY TIMER Operation......23

Care

Care and Cleaning 29

■ When the Need Arises

FAQ 34

Troubleshooting 35

Safety Precautions

DAIKIN Cora FTKM20Q2VMA - Safety Precautions - 1

Read the precautions in this manual carefully before operating the unit.

DAIKIN Cora FTKM20Q2VMA - Safety Precautions - 2

This appliance is filled with R32.

  • Keep this manual where the user can easily find it.
  • The precautions described herein are classified as WARNING and CAUTION. They both contain important information regarding safety. Be sure to observe all precautions without fail.

DAIKIN Cora FTKM20Q2VMA - Safety Precautions - 3

WARNING

Failure to follow these instructions properly may result in personal injury or loss of life.

DAIKIN Cora FTKM20Q2VMA - WARNING - 1

CAUTION

Failure to follow these instructions properly may result in property damage or personal injury, which may be serious depending on the circumstances.

DAIKIN Cora FTKM20Q2VMA - CAUTION - 1

Never attempt.

DAIKIN Cora FTKM20Q2VMA - CAUTION - 2

Be sure to follow the instructions.

DAIKIN Cora FTKM20Q2VMA - CAUTION - 3

Be sure to establish an earth connection.

DAIKIN Cora FTKM20Q2VMA - CAUTION - 4

Never touch the air conditioner nor the remote controller with wet hands.

DAIKIN Cora FTKM20Q2VMA - CAUTION - 5

Never wet the air conditioner nor the remote controller

• After reading, keep this manual in a convenient place so that you can refer to it whenever necessary. If the equipment is transferred to a new user, be sure also to hand over the manual.

DAIKIN Cora FTKM20Q2VMA - CAUTION - 6

WARNING

DAIKIN Cora FTKM20Q2VMA - WARNING - 1

  • Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
  • The appliance must be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater).
  • Do not pierce or burn.
  • Be aware that refrigerants may not contain an odour.
  • The appliance must be installed, operated and stored in a room with a floor area larger than 4.6m^2 for 50/60 class, 4.9m^2 for 71class.
    • To avoid fire, explosion or injury, do not operate the unit when harmful gases (e.g. flammable or corrosive) are detected near the unit.
  • Be aware that prolonged, direct exposure to cool or warm air from the air conditioner, or to air that is too cool or too warm, can be harmful to your physical condition and health.
  • Do not place objects, including rods, your fingers, etc., in the air inlet or outlet. Product damage or personal injury may result due to contact with the air conditioner's high-speed fan blades.
  • Do not attempt to repair, dismantle, reinstall or modify the air conditioner yourself as this may result in water leakage, electric shocks or fire hazards.
  • Do not use flammable spray near the air conditioner, or otherwise fire may result.
  • When the air conditioner is malfunctioning (giving off a burning odour, etc.) turn off power to the unit and contact your local dealer. Continued operation under such circumstances may result in a failure, electric shocks or fire hazards.
  • Do not use a refrigerant other than the one indicated on the outdoor unit (R32) when installing, moving or repairing. Using other refrigerants may cause trouble or damage to the unit, and personal injury.

DAIKIN Cora FTKM20Q2VMA - WARNING - 2

- To avoid electric shocks, do not operate with wet hands.

DAIKIN Cora FTKM20Q2VMA - WARNING - 3

- Beware of fire in case of refrigerant leakage. If the air conditioner is not operating correctly, i.e. not generating cool or warm air, refrigerant leakage could be the cause. Consult your dealer for assistance. The refrigerant within the air conditioner is safe and normally does not leak.

However, in the event of a leakage, contact with a naked burner, heater or cooker may result in generation of noxious gas. Do not use the air conditioner until a qualified service person confirms that the leakage has been repaired.

  • Do not attempt to install or repair the air conditioner yourself. Improper workmanship may result in water leakage, electric shocks or fire hazards. Please contact your local dealer or qualified personnel for installation and maintenance work.
  • If the air conditioner is malfunctioning (giving off a burning odour, etc.), turn off power to the unit and contact your local dealer. Continued operation under such circumstances may result in a failure, electric shocks or fire hazards.
  • Be sure to install an earth leakage circuit breaker. Failure to install an earth leakage circuit breaker may result in electric shocks or fire.
  • Be sure to earth the unit. Do not earth the unit to a utility pipe, lightning conductor or telephone earth lead. Imperfect earthing may result in electric shocks.

DAIKIN Cora FTKM20Q2VMA - WARNING - 4

CAUTION

DAIKIN Cora FTKM20Q2VMA - CAUTION - 1

  • Do not use the air conditioner for purposes other than those for which it is intended. Do not use the air conditioner for cooling precision instruments, food, plants, animals or works of art as this may adversely affect the performance, quality and/or longevity of the object concerned.
  • Do not expose plants or animals directly to the airflow from the unit as this may cause adverse effects.
  • Do not place appliances that produce naked flames in places exposed to the airflow from the unit as this may impair combustion of the burner.

DAIKIN Cora FTKM20Q2VMA - CAUTION - 2

CAUTION

DAIKIN Cora FTKM20Q2VMA - CAUTION - 1

  • Do not block the air inlets nor outlets. Impaired airflow may result in insufficient performance or trouble.
  • Do not sit on the outdoor unit, put things on the unit, or pull the unit. Doing so may cause accidents, such as falling or toppling down, thus resulting in injury, product malfunctioning, or product damage.
  • Do not give impact to the indoor and outdoor units, or otherwise product damage may result.
  • Do not place objects that are susceptible to moisture directly beneath the indoor or outdoor units. Under certain conditions, condensation on the main unit or refrigerant pipes, air filter dirt or drain blockage may cause dripping, resulting in fouling or failure of the object concerned.
  • After prolonged use, check the unit stand and its mounts for damage. If they are left in a damaged condition, the unit may fall and cause injury.
  • To avoid injury, do not touch the air inlet or aluminium fins of the indoor or outdoor units.
  • The appliance is not intended for use by unattended young children or infirm persons. Impairment of bodily functions and harm to health may result.
  • Children should be supervised to ensure that they do not play with the unit or its remote controller. Accidental operation by a child may result in impairment of bodily functions and harm health.
  • Do not place flammable items, such as spray cans, within 1m of the air outlet.
    The spray cans may explode as a result of hot air from the indoor or outdoor units.
  • Be careful not to let pets urinate on the air conditioner. Urination on the air conditioner may result in electric shocks or fire.
  • Do not sit or hang on the panel. The panel may fall, and injury or product malfunctioning may result.
  • Do not sway the panel. The panel may hit people or objects, and injury or property damage may result.
  • Do not let children play around the panel. Injury or property damage may result.
  • Do not pull the wires. The wires may be broken and the panel may fall, and injury or property damage may result.
  • Do not locate obstacles in the route. The panel may fall, and injury or property damage may result.
  • Do not bend or damage the wires. The wires may be broken and the panel may fall, and injury or property damage may result.
  • Do not wash the air conditioner with water, as this may result in electric shocks or fire.
  • Do not place water containers (vases, etc.) above the unit, as this may result in electric shocks or fire hazards if they should topple over.
  • Do not put objects on the panel, or otherwise production malfunctioning may result.
  • Do not use an unstable stand at the time of operating or maintaining the air conditioner, or otherwise you may topple over or injury yourself.
  • Locate the remote controller in places out of reach of children. The wrong operation of the remote controller may result in injury.
  • To avoid oxygen depletion, ensure that the room is adequately ventilated if equipment such as a burner is used together with the air conditioner.
  • Before cleaning, be sure to stop unit operation and turn off the circuit breaker. Otherwise, an electric shock and injury may result.
  • Only connect the air conditioner to the specified power supply circuit. Power supplies other than the one specified may result in electric shocks, overheating and fires.
  • Arrange the drain hose to ensure smooth drainage. Imperfect drainage may cause wetting of the building, furniture, etc.
  • Do not place objects in direct proximity of the outdoor unit and do not let leaves and other debris accumulate around the unit. Leaves are a hotbed for small animals which can enter the unit. Once inside the unit, such animals can cause malfunctions, smoke or fire if they come into contact with electrical parts.
  • Do not place objects around the indoor unit.
    Doing so may have an adverse influence on the performance, product quality, and life of the air conditioner.

DAIKIN Cora FTKM20Q2VMA - CAUTION - 2

Installation site

■ To install the air conditioner in the following types of environments, consult your dealer.

  • Places with an oily environment or where steam or soot occurs.
  • Salty environments such as coastal areas.
  • Places where sulphide gas occurs such as hot springs.
  • Places where snow may block the outdoor unit.

■ Be sure to follow the instructions below.

• The indoor unit is at least 1m away from any television or radio set (unit may cause interference with the picture or sound).
- The drain from the outdoor unit must be discharged to a place of good drainage.

Consider nuisance to your neighbours from noises

■ For installation, choose a place as described below.

  • A place solid enough to bear the weight of the unit and which does not amplify the operation noise or vibration.
  • A place from where the air discharged from the outdoor unit or the operation noise will not annoy your neighbours.

Electrical work

■ Fdhe power supply, be sure to use a separate power circuit dedicated to the air conditioner.

System relocation

■ Relocating the air conditioner requires specialized knowledge and skills. Please consult your dealer if relocation is necessary for moving or remodelling.

Names of Parts

Indoor Unit

DAIKIN Cora FTKM20Q2VMA - Indoor Unit - 1

text_image Deodorizing filter (enzyme blue) Air Filter Front panel Air inlet Horizontal blade (Flap) : ▶ Page 13 Vertical blades (Louvers) • The Louvers are inside of the air outlet. ▶ Page 13 Display Name Air outlet Room temperature sensor • It senses the air tempera ture around the unit. Panel tab INTELLIGENT EYE sensor • Detects the movements of people and automatically switches between normal operation and energy saving operation. ▶Page 16

Display

Signal receiver

  • It receives signals from the remote controller.
  • When the unit receives a signal, you will hear a short beep.
    • Operation start ...... beep-beep
  • Settings changed .... beep
    • Operation stop ...... beeeeeep

DAIKIN Cora FTKM20Q2VMA - Signal receiver - 1

text_image Operation lamp (green) TIMER lamp (orange) : ▶Page 20,21,22,25,27 ON/OFF INTELLIGENT EYE lamp (green) : ▶Page 16

Indoor Unit ON/OFF switch

  • Push this switch once to start operation. Push once again to stop it.
  • The operation mode refer to the following table.
ModeTemperature settingAirflow rate
COOL22°CAUTO

- This switch can be used when the remote controller is missing.

■ Open the front panel
DAIKIN Cora FTKM20Q2VMA - Indoor Unit ON/OFF switch - 1

text_image Air filter Deodorizing filter (enzyme blue)

Outdoor Unit
DAIKIN Cora FTKM20Q2VMA - Indoor Unit ON/OFF switch - 2

text_image Air inlet (back and side) Outdoor temperature sensor (back) Refrigerant piping and inter-unit wiring Earth terminal (inside) Drain hose Model name plate Air outlet

Names of Parts

Remote Controller

DAIKIN Cora FTKM20Q2VMA - Remote Controller - 1

text_image Signal transmitter Receiver To use the remote controller, aim the transmitter at the indoor unit. If there is anything blocking the signals between the unit and the remote controller, such as a curtain, the unit may not operate. The maximum transmission distance is about 7m. Display (LCD) Displays the current settings. (In this illustration, each section is shown with all its displays on for the purpose of explanation.) TEMPERATURE adjustment button Changes the temperature setting. ▶ Page 12 FAN setting button Selects the airflow rate setting. ▶ Page 14 POWERFUL button POWERFUL operation. ▶ Page 18 ON/OFF button Press this button once to start operation. Press once again to stop it. ▶ Page 11 Front cover Open the front cover. ▶ Page 8 Model name ARC466A29

■ Open the front cover

DAIKIN Cora FTKM20Q2VMA - ■ Open the front cover - 1

text_image MODE selector button • Selects the operation mode. (DRY/COOL/FAN) ▶ Page 11 ECONO/QUIET button • ECONO/OUTDOOR UNIT QUIET operation. ▶ Page 19 SENSOR button • INTELLIGENT EYE operation. ▶ Page 16 COMFORT button • COMFORT AIRFLOW operation. ▶ Page 15 SWING button • Adjusts the airflow direction. ▶ Page 13 OFF TIMER button (NIGHT SET mode) ▶ Page 21 TIMER CANCEL button • Cancels the timer setting. ▶ Page 20,21 • Cannot be used for the WEEKLY TIMER operation. SELECT button • Changes the clock, ON/OFF TIMER and WEEKLY TIMER settings. Timer Copy Back Select On Cancel Off Cancel Timer + - ▼ ON TIMER button ▶ Page 20 CLOCK button ▶ Page 10

Preparation Before Operation

DAIKIN Cora FTKM20Q2VMA - Preparation Before Operation - 1

text_image Position + and - correctly!

*The remote controller may differ from some models.

To insert the batteries

  1. Slide the front cover to take it off.
  2. Insert 2 dry batteries AAA.LR03 (alkaline).
  3. Replace the front cover.

DAIKIN Cora FTKM20Q2VMA - To insert the batteries - 1

text_image Remote controller Screws Remote controller holder

To fix the remote controller holder to a wall

  1. Choose a place from where the signals reach the unit.
  2. Fix the holder to a wall, a pillar, or similar location with the screws supplied with the holder.
  3. Place the remote controller in the remote controller holder.

Turn on the circuit breaker

- After the power is turned on, the flaps of the indoor unit open and close once to set the reference position.

NOTE

Notes on batteries

  • When replacing the batteries, use batteries of the same type, and replace both old batteries together.
  • The batteries will last for about 1 year. If the remote controller display begins to fade and the possible transmission range becomes shorter within a year, however, replace both batteries with new, size AAA.LR03 (alkaline).
  • The batteries supplied with the remote controller are for initial operation. The batteries may run out in less than 1 year.

Note on remote controller

- Do not drop the remote controller. Do not get it wet.

DAIKIN Cora FTKM20Q2VMA - Note on remote controller - 1

text_image 27.0°C MON 15:30 Select Timer

*The remote controller may differ from some models.

To set the clock

1. Press

DAIKIN Cora FTKM20Q2VMA - Press - 1

"0.00 is displayed on the LCD.

"MON" and "④ blink.

2. Press to set the current day of the week.

3. Press

DAIKIN Cora FTKM20Q2VMA - Press - 1

“ ℝ blinks.

4. Press to set the clock to the present time.

- Holding down ▲ or ▼ rapidly increases or decreases the displayed time.

5. Press

- Point the remote controller at the indoor unit when pressing the buttons.

DAIKIN Cora FTKM20Q2VMA - Press - 1

“*” blinks.

NOTE

Note on setting the clock

- If the indoor unit's internal clock is not set to the correct time, the ON/OFF TIMER and WEEKLY TIMER will not operate punctually.

DAIKIN Cora FTKM20Q2VMA - Note on setting the clock - 1

DRY · COOL · FAN Operation

DAIKIN Cora FTKM20Q2VMA - DRY · COOL · FAN Operation - 1

text_image ON 27.0°C * ON MON 15:30 On/Off Mode Timer

The air conditioner operates with the operation mode of your choice.

From the next time on, the air conditioner will operate with the same operation mode.

To start operation

1. Press and select a operation mode.

• Each pressing of the button changes the mode setting in sequence.

DAIKIN Cora FTKM20Q2VMA - Press and select a operation mode. - 1

flowchart
graph LR
    A["DRY COOL FAN"] --> B["Product 1"]
    B --> C["Product 2"]
    C --> D["Product 3"]

2. Press On/Off

• “ ON displayed on the LCD.
• The OPERATION lamp lights green.

DAIKIN Cora FTKM20Q2VMA - Press On/Off - 1

text_image Simple diagram with a rectangle, sun, and icons including a plus sign, a person, and a circle, likely representing a conceptual or basic process.

Display

To stop operation

Press again.

• “ On appears from the LCD.
• The OPERATION lamp goes off.

NOTE

Note on DRY operation

- Eliminates humidity while maintaining the indoor temperature as much as possible. It automatically controls temperature and airflow rate, so manual adjustment of these functions is unavailable.

DAIKIN Cora FTKM20Q2VMA - Note on DRY operation - 1

text_image ON 27.0°C MON 15:30 Temp Timer

To change the temperature setting

DAIKIN Cora FTKM20Q2VMA - To change the temperature setting - 1

Press

DAIKIN Cora FTKM20Q2VMA - Press - 1

- Press ▲ to raise the temperature and press ▼ to lower the temperature.

COOL operationDRY or FAN operation
18.0 – 32.0°CThe temperature setting cannot be changed.

Tips for saving energy

Keeping the temperature setting at a moderate level helps save energy.

- Recommended temperature setting

- For cooling : 26.0-28.0°C

Cover windows with a blind or a curtain.

- Blocking sunlight and air from outdoors increases the cooling effect.

Keep the air filters clean.

• Clogged air filters cause inefficient operation and waste energy. Clean them once in about every 2 weeks. ▶ Page 31

DAIKIN Cora FTKM20Q2VMA - Tips for saving energy - 1

natural_image Stylized plant branch illustration with leaves and stems, rendered in grayscale geometric shapes (no text or symbols)

If you are not going to use the air conditioner for a long period, for example in spring or autumn, turn off the circuit breaker.

- The air conditioner always consumes a small amount of electricity even while it is not operating.

DAIKIN Cora FTKM20Q2VMA - Tips for saving energy - 2

Adjusting the Airflow Direction

DAIKIN Cora FTKM20Q2VMA - Adjusting the Airflow Direction - 1

text_image MASTER 27.0°C A MON 15:30 Switch Timer

You can adjust the airflow direction to increase your comfort.

ATTENTION

• Always use a remote controller to adjust the angles of the flaps and louvres.
- If you attempt to move the flaps and louvres forcibly by hand when they are swinging, the mechanism may be damaged.
- Inside the air outlet, a fan is rotating at a high speed.

To start auto swing

Up and down airflow direction

DAIKIN Cora FTKM20Q2VMA - Up and down airflow direction - 1

Press

DAIKIN Cora FTKM20Q2VMA - Press - 1

  • “C” is displayed on the LCD.
  • The flaps (horizontal blades) will begin to swing.

DAIKIN Cora FTKM20Q2VMA - Press - 2

natural_image Diagram showing a circular icon with rotation arrows and a server icon, no text or symbols present

Right and left airflow direction

DAIKIN Cora FTKM20Q2VMA - Right and left airflow direction - 1

Press

DAIKIN Cora FTKM20Q2VMA - Press - 1

  • “” is displayed on the LCD.
    • The louvres (vertical blades) will begin to swing.

DAIKIN Cora FTKM20Q2VMA - Press - 2

natural_image Diagram showing airflow around a car with a curved arrow indicating direction (no text or symbols)

The 3-D airflow direction

DAIKIN Cora FTKM20Q2VMA - The 3-D airflow direction - 1

Press

DAIKIN Cora FTKM20Q2VMA - Press - 1

  • “ ⏻” and “ 📋” are displayed on the LCD.
    • The flaps and louvres move in turn.
  • To cancel 3-D airflow, press either 📁 or again. The flaps or louvres will stop moving.

DAIKIN Cora FTKM20Q2VMA - Press - 2

natural_image Diagram showing airflow around a car air conditioner unit with control panel (no text or symbols)

To set the flaps or louvres at the desired position

- This function is effective while the flaps or louvres are in auto swing mode.

DAIKIN Cora FTKM20Q2VMA - To set the flaps or louvres at the desired position - 1

sserP

DAIKIN Cora FTKM20Q2VMA - sserP - 1

whandthe flaps or louvres

reach the desired position.

• In the 3-D airflow, the flaps and louvres move in turn.
- “” or “” disappears from the LCD.

DAIKIN Cora FTKM20Q2VMA - reach the desired position. - 1

Adjusting the Airflow Rate

DAIKIN Cora FTKM20Q2VMA - Adjusting the Airflow Rate - 1

text_image 27:00 MON 15:30 Fan

You can adjust the airflow rate to increase your comfort.

To adjust the airflow rate setting

DAIKIN Cora FTKM20Q2VMA - To adjust the airflow rate setting - 1

• Each pressing ☐ of changes the airflow rate setting in sequence.

DAIKIN Cora FTKM20Q2VMA - To adjust the airflow rate setting - 2

flowchart
graph LR
    A["AUTOIndoor unit quiet Airflow rate 1-5 (Low to High)"] --> B["AUTOIndoor unit quiet Airflow rate 1-5 (Low to High)"]
    B --> C["AUTOIndoor unit quiet Airflow rate 1-5 (Low to High)"]
    C --> D["AUTOIndoor unit quiet Airflow rate 1-5 (Low to High)"]
  • When operation starts and noise from the indoor unit will become quieter.
  • In the quiet operation mode, the airflow rate is set to a weak level.
COOL and FAN operation DRY operation
The airflow rate setting cannot be changed.

NOTE

Note on airflow direction setting

- The movable range of the flaps varies according to the operation mode.

Movable range of the flap

DAIKIN Cora FTKM20Q2VMA - Note on airflow direction setting - 1

text_image of the flap COOL / DRY FAN

Note on 3-D airflow

- Using 3-D airflow circulates cold air, which tends to collected at the bottom of the room, and hot air, which tends to collect near the ceiling, throughout the room, preventing areas of cold and hot developing.

Note on airflow rate setting

- At smaller airflow rates, the cooling effect is also smaller.

DAIKIN Cora FTKM20Q2VMA - Note on airflow rate setting - 1

COMFORT AIRFLOW Operation

DAIKIN Cora FTKM20Q2VMA - COMFORT AIRFLOW Operation - 1

text_image 27.0°C MON 15:30 Comfort Timer

COMFORT AIRFLOW operation: The air direction and flow rate are adjusted so that the air will not blow directly at people in the room.

To start COMFORT AIRFLOW operation

DAIKIN Cora FTKM20Q2VMA - To start COMFORT AIRFLOW operation - 1

• “ 🍼 is displayed on the LCD.

COOL and DRY operation FAN operation
Flap directionGoes upNot available
Airflow rateAUTO

To cancel COMFORT AIRFLOW operation

Press again.

• “ disappears from the LCD.
- The flap will return to the memory position from before COMFORT AIRFLOW operation.

Notes on "COMFORT AIRFLOW Operation"

• The flap position will change, preventing air from blowing directly on the occupants of the room.
- POWERFUL operation and COMFORT AIRFLOW operation cannot be used at the same time.
- The volume of air will be set to AUTO. If the upward and downward airflow direction is selected, the COMFORT AIRFLOW function will be canceled.
- Priority is given to the function of whichever button is pressed last.
- The COMFORT AIRFLOW function makes the following airflow direction adjustments. The flaps will move upward while cooling so that the airflow will be directed upward.

DAIKIN Cora FTKM20Q2VMA - Notes on "COMFORT AIRFLOW Operation" - 1

natural_image Diagram of a airflow or ventilation system with a car on a wall (no text or symbols)

Cooling operation

DAIKIN Cora FTKM20Q2VMA - Notes on "COMFORT AIRFLOW Operation" - 2

INTELLIGENT EYE Operation

DAIKIN Cora FTKM20Q2VMA - INTELLIGENT EYE Operation - 1

text_image 27.0°C MON 15:30 Sensor Timer

The INTELLIGENT EYE operation detects human movement. If no one is detected in the room for more than 20 minutes, the unit automatically enters energy saving operation.

CAUTION

  • Do not place large objects near the INTELLIGENT EYE sensor. Also keep heating units and humidifi ers outside the sensor's detection area. This sensor can detect undesirable objects.
  • Do not hit or violently push the INTELLIGENT EYE sensor. This can lead to damage and malfunction.

To start INTELLIGENT EYE operation

DPress

DAIKIN Cora FTKM20Q2VMA - DPress - 1

and select the desired model.

• Each time is pressed, a different setting option is displayed on the LCD.
• The INTELLIGENT EYE lamp lights green.

DAIKIN Cora FTKM20Q2VMA - and select the desired model. - 1

text_image Simple diagram with a person, clock, and sun icons, possibly representing a conceptual or symbolic representation.

Display

DAIKIN Cora FTKM20Q2VMA - and select the desired model. - 2

flowchart
graph LR
    A["Sensor"] --> B["blank"]
    B --> C["No Setting Intelligent eye"]

- The lamp lights when human movement is detected.

To cancel the INTELLIGENT EYE operation

Press

DAIKIN Cora FTKM20Q2VMA - Press - 1

button.

• The INTELLIGEN EYE lamp goes off.

DAIKIN Cora FTKM20Q2VMA - button. - 1

INTELLIGENT EYE Operation

The INTELLIGENT EYE operation detects human movement.

If no one is detected in the room for more than 20 minutes, the unit automatically enters energy saving operation.

INTELLIGENT EYE operation is useful for energy saving

■ People is detected in the sensing area.
DAIKIN Cora FTKM20Q2VMA - INTELLIGENT EYE operation is useful for energy saving - 1

natural_image Illustration of a person sitting on a sofa using a device, with no visible text or symbols

The air conditioner is in normal operation while the sensor is detecting human movement.

■ No people are detected in the sensing area.
DAIKIN Cora FTKM20Q2VMA - INTELLIGENT EYE operation is useful for energy saving - 2

natural_image Diagram showing a car above a sofa with a downward arrow indicating motion (no text or symbols)

The air conditioner will switch to energy-saving mode after 20 minutes.

Energy saving operation

  • If no presence detected in the room for 20 minutes, energy saving operation starts automatically.
  • This operation changes the temperature by +2^ in COOL / +2^ in DRY operation from the set temperature.
    When the room temperature exceeds 30^ C, the operation changes the temperature by +1^ C in COOL / +1^ C in DRY operation from the set temperature.
  • This operation decreases the airflow rate slightly in FAN operation only.

NOTE

Note on COMFORT AIRFLOW operation

- The airflow rate will be set to AUTO. If the up and down airflow direction is selected, COMFORT AIRFLOW operation will be cancelled.

Notes on INTELLIGENT EYE operation

- Application range is as follows.

DAIKIN Cora FTKM20Q2VMA - Notes on INTELLIGENT EYE operation - 1

text_image Vertical angle 90° (Side view) 7m 90°

DAIKIN Cora FTKM20Q2VMA - Notes on INTELLIGENT EYE operation - 2

text_image Horizontal angle 110° (Top view) 55° 55° 7m
  • The sensor may not detect moving objects further than 7m away. (Please see the application range)
  • Sensor detection sensitivity changes according to the indoor unit location, the speed of passers-by, temperature range, etc.
  • The sensor could also mistakenly detect pets, sunlight, fluttering curtains and light reflected off of mirrors as passers-by.
  • INTELLIGENT EYE operation will not switch on during POWERFUL operation.
  • NIGHT SET mode ▶ Page 21 will not switch on during use of INTELLIGENT EYE operation.

Note on combination of COMFORT AIRFLOW operation and INTELLIGENT EYE operation

- The airflow rate will be set to AUTO. If the up and down airflow direction is selected, COMFORT AIRFLOW operation will be canceled. Priority is given to the function of whichever button is pressed last.

DAIKIN Cora FTKM20Q2VMA - Note on combination of COMFORT AIRFLOW operation and INTELLIGENT EYE operation - 1

POWERFUL Operation

DAIKIN Cora FTKM20Q2VMA - POWERFUL Operation - 1

text_image ON 27.0°C MON 15:30 Powerful

POWERFUL operation quickly maximizes the cooling effect in any operation mode. In this mode, the air conditioner operates at maximum capacity.

To start POWERFUL operation

Press during operation.

• “ Is displayed on the LCD.
- POWERFUL operation ends in 20 minutes. Then the system automatically operates again with the previous settings which were used before POWERFUL operation.

To cancel POWERFUL operation

Press again.

• “ disappears from the LCD.

NOTE

Notes on POWERFUL operation

  • Pressing ⏻ causes the settings to be cancelled, and “💡” disappears from the LCD.
  • POWERFUL operation will not increase the capacity of the air conditioner if the air conditioner is already in operation with its maximum capacity demonstrated.
  • In COOL operation
    To maximize the cooling effect, the capacity of outdoor unit increases and the airflow rate becomes fixed at the maximum setting.
    The temperature and airflow settings cannot be changed.
  • In DRY operation
    The temperature setting is lowered by 2.5^ C and the airflow rate is slightly increased.
  • In FAN operation
    The airflow rate is fixed at the maximum setting.

Regarding the combination of POWERFUL and other operations

POWERFUL + COMFORT AIRFLOWNot available*
POWERFUL + ECONO
POWERFUL + OUTDOOR UNIT QUIET

*Priority is given to the function of whichever button is pressed last.

DAIKIN Cora FTKM20Q2VMA - Notes on POWERFUL operation - 1

ECONO / OUTDOOR UNIT QUIET Operation

DAIKIN Cora FTKM20Q2VMA - ECONO / OUTDOOR UNIT QUIET Operation - 1

text_image 27.0°C MON 15:30 Ecoa/Outlet Timer

ECONO operation enables efficient operation by limiting the maximum power consumption.

This function is useful to prevent the circuit breaker from tripping when the unit operates alongside other appliances on the same circuit.

OUTDOOR UNIT QUIET operation lowers the noise level of the outdoor unit by changing the frequency and fan speed of the outdoor unit. This function is convenient during the night-time operation.

To start operation

Press Econo/Quiet and select the desired mode.

• Each time is pressed, a different setting option is displayed on the LCD.

DAIKIN Cora FTKM20Q2VMA - To start operation - 1

flowchart
graph LR
    A["ECONO OUTDOOR UNIT QUIET"] --> B["Combination"]
    B --> C["blank\nNo Setting"]

To cancel operation

Press Econo/Quiet until no icon is displayed.

NOTE

Notes on ECONO operation

  • Pressing ⏻ causes the settings to be cancelled, and “ ↘” disappears from the LCD.
  • If the power consumption level is already low, switching to ECONO operation will not reduce the power consumption.

Notes on OUTDOOR UNIT QUIET operation

  • Even if the operation is stopped by using the remote controller or the indoor unit ON/OFF switch when using OUTDOOR UNIT QUIET operation, "Cavill remain lit on the remote controller display.
  • OUTDOOR UNIT QUIET operation will not reduce the frequency nor fan speed if they already are operating at reduced levels.
  • This operation is performed with lower power and therefore may not provide a sufficient cooling effect.

Possible combinations of ECONO / OUTDOOR UNIT QUIET operation and basic operations

Operation mode
DRY COOLFAN
ECONO×
OUTDOOR UNIT QUIET××

DAIKIN Cora FTKM20Q2VMA - Notes on OUTDOOR UNIT QUIET operation - 1

ON/OFF TIMER Operation

DAIKIN Cora FTKM20Q2VMA - ON/OFF TIMER Operation - 1

text_image 27.0°C ON 6:00 Select Cancel On Timer

Timer functions are useful for automatically switching the air conditioner on or off at night or in the morning. You can also use the ON TIMER and OFF TIMER together.

To use ON TIMER with a 24 hour clock display (24 HOUR ON/OFF TIMER)

  • Check that the clock is correct.
    If not, set the clock to the present time. ▶ Page 10
    • To set the ON TIMER in an hours remaining display. ▶ Page 10

DAIKIN Cora FTKM20Q2VMA - To use ON TIMER with a 24 hour clock display (24 HOUR ON/OFF TIMER) - 1

text_image 1. Press On ON 6:00 "8:00" "ON"

- “①” and day of the week disappear from the LCD.

2. Press until the time setting reaches the point you like.

• Each pressing of either button increases or decreases the time setting by 10 minutes. Holding down either button changes the setting rapidly.

3. Press □ again.

  • "ONand setting time are displayed on the LCD.
    • The TIMER lamp lights orange.

DAIKIN Cora FTKM20Q2VMA - Press □ again. - 1

flowchart
graph TD
    A["Square"] --> B["Directional Arrow"]
    B --> C["Sun Icon"]
    C --> D["Circle Node"]
    D --> E["Circle Node"]
    E --> F["Circle Node"]
    F --> G["Circle Node"]
    G --> H["Circle Node"]
    H --> I["Circle Node"]
    I --> J["Circle Node"]
    J --> K["Circle Node"]
    K --> L["Circle Node"]
    L --> M["Circle Node"]
    M --> N["Circle Node"]
    N --> O["Circle Node"]
    O --> P["Circle Node"]
    P --> Q["Circle Node"]
    Q --> R["Circle Node"]
    R --> S["Circle Node"]
    S --> T["Circle Node"]
    T --> U["Circle Node"]
    U --> V["Circle Node"]
    V --> W["Circle Node"]
    W --> X["Circle Node"]
    X --> Y["Circle Node"]
    Y --> Z["Circle Node"]

Display

To cancel ON TIMER operation

DAIKIN Cora FTKM20Q2VMA - To cancel ON TIMER operation - 1

  • “ONand setting time disappear from the LCD.
  • “💡” and day of the week are displayed on the LCD.
    • The TIMER lamp goes off.

NOTE

Note on TIMER operation

- When TIMER is set, the present time is not displayed.

In the following cases, set the timer again.

• After the circuit breaker has turned off.
• After a power failure.
• After replacing the batteries in the remote controller.

DAIKIN Cora FTKM20Q2VMA - In the following cases, set the timer again. - 1

ON/OFF TIMER Operation

DAIKIN Cora FTKM20Q2VMA - ON/OFF TIMER Operation - 1

text_image 27.0°C OFF 0:00 Off Select Cancel Timer

To use OFF TIMER with a 24 hour clock display (24 HOUR ON/OFF TIMER)

  • Check that the clock is correct.
    If not, set the clock to the present time. ▶ Page 10
    • To set the ON TIMER in an hours remaining display. ▶ Page 10

1. Press Off

DAIKIN Cora FTKM20Q2VMA - Press Off - 1

"0.08 displayed on the LCD.

"OFF" blinks.

- “ ⊕” and day of the week disappear from the LCD.

2. Press until the time setting reaches the point you like.

- Each pressing of either button increases or decreases the timem setting by 10 minutes. Holding down either button changes the time setting rapidly.

3. Press again.

  • “OFF and setting time are displayed on the LCD.
    • The TIMER lamp lights orange.

DAIKIN Cora FTKM20Q2VMA - Press again. - 1

flowchart
graph TD
    A[" "] --> B[" "]
    B --> C[" "]
    C --> D[" "]
    D --> E[" "]
    E --> F[" "]
    F --> G[" "]
    G --> H[" "]
    H --> I[" "]
    I --> J[" "]
    J --> K[" "]
    K --> L[" "]
    L --> M[" "]
    M --> N[" "]
    N --> O[" "]
    O --> P[" "]
    P --> Q[" "]
    Q --> R[" "]
    R --> S[" "]
    S --> T[" "]
    T --> U[" "]
    U --> V[" "]
    V --> W[" "]
    W --> X[" "]
    X --> Y[" "]
    Y --> Z[" "]

Display

To cancel OFF TIMER operation

Press Cancel

  • “OFF and setting time disappear from the LCD.
  • “ ⊕” and day of the week are displayed on the LCD.
    • The TIMER lamp goes off.

To combine ON TIMER and OFF TIMER

- A sample setting for combining the 2 timers is shown below.

DAIKIN Cora FTKM20Q2VMA - To combine ON TIMER and OFF TIMER - 1

text_image (Example) Present time: 23:00 (The unit operating) OFF TIMER at 0:00 ON TIMER at 14:00) Combined OFF 0:00 ON 14:00

NOTE

NIGHT SET mode

- When the OFF TIMER is set, the air conditioner automatically adjusts the temperature setting (0.5°C up in COOL) to prevent excessive cooling during sleeping hours.

DAIKIN Cora FTKM20Q2VMA - NIGHT SET mode - 1

text_image 27.8°C ON ihr Select On Cancel Timer

To use the ON/OFF TIMER with an hours remaining display (COUNT UP-DOWN ON/OFF TIMER)

- Check that the clock is correct.

If not, set the clock to the present time. ▶ Page 10

DAIKIN Cora FTKM20Q2VMA - Press and hold or for about 5 seconds, when signal indicator (▲) blink, release your finger from the button. - 1

For ON TIMER

"Ibr" is displayed on the LCD.

"ON" blinks.

For OFF TIMER

"Ibr" is displayed on the LCD.

"OFF" blinks.

- “ ⏻ ” and day of the week disappear from the LCD.

2. Press until the time setting reaches the point you like.

• Each pressing of the button increases or decreases the time setting by 1 hour.

• The time can be set between 1 and 12 hours.

3. Press on or again.

  • “ON” or “OFF”, and setting time are displayed on the LCD.
    • The TIMER lamp lights orange.

DAIKIN Cora FTKM20Q2VMA - Press on or again. - 1
Display

  • To change the display mode from COUNT UP-DOWN ON/OFF TIMER to 24 HOUR ON/OFF TIMER, repeat STEP 1, and continue from STEP 2 of "24 HOUR ON/OFF TIMER". ▶ Page 20.21
  • Timer display mode cannot be changed while "ON" or "OFF" are blinking. Press ☐ or ☐ to stop the blinking.

Combining display modes

- Different display modes (24 HOUR ON/OFF TIMER and COUNT UP-DOWN ON/OFF TIMER) can be used for the ON TIMER and OFF TIMER simultaneously.

(Example)

Present time: 22:00 [unit is in operation] OFF TIMER at 1:00 (3 hours after present time) ON TIMER at 6:00 (8 hours after present time) Combined

DAIKIN Cora FTKM20Q2VMA - Combining display modes - 1

text_image OFF 3hr ON 6:00 OFF 1:00 ON 8hr OFF 3hr ON 8hr

NOTE

Notes on COUNT UP-DOWN ON/OFF TIMER

- After setting, the time displayed on the LCD will automatically count down by 1 hour for every 1 hour that passes. For example, if the OFF TIMER is set to 3 hours, the display will change as follows: 3hr 2hr 1hr blank (OFF)

Switching between ON/OFF TIMER display modes (24 hour clock and hours remaining display)

- When change display mode (from 24 HOUR ON/OFF TIMER to COUNT UP-DOWN ON/OFF TIMER or from COUNT UP-DOWN ON/OFF TIMER to 24 HOUR ON/OFF TIMER), cancel timer. So, to use timer, set timer again.

DAIKIN Cora FTKM20Q2VMA - Switching between ON/OFF TIMER display modes (24 hour clock and hours remaining display) - 1

WEEKLY TIMER Operation

Up to 4 timer settings can be saved for each day of the week. This is convenient to adapt the WEEKLY TIMER to your family's life style.

Setting example of the WEEKLY TIMER

The same timer settings are used from Monday through Friday, while different timer settings are used for the weekend.

[Monday]Make timer settings for programmes 1-4. ▶Page 24Programme 1 Programme 2 Programme 3 Programme 4
DAIKIN Cora FTKM20Q2VMA - Setting example of the WEEKLY TIMER - 1
[Tuesday] to [Friday]Use thosePr DAIKIN Cora FTKM20Q2VMA - Setting example of the WEEKLY TIMER - 2
[Saturday]No timer settings
[Sunday]Maki DAIKIN Cora FTKM20Q2VMA - Setting example of the WEEKLY TIMER - 3
  • Up to 4 reservations per day and 28 reservations per week can be set using the WEEKLY TIMER. The effective use of the copy mode simplifies timer programming.
  • The use of ON-ON-ON-ON settings, for example, makes it possible to schedule operating mode and set temperature changes. Furthermore, by using OFF-OFF-OFF-OFF settings, only the turn off time of each day can be set. This will turn off the air conditioner automatically if you forget to turn it off.

DAIKIN Cora FTKM20Q2VMA - Setting example of the WEEKLY TIMER - 4

text_image 27.0°C ON 6:00 MON 25.0°C Select Next Timer

To use WEEKLY TIMER operation

Setting mode

• Make sure the day of the week and time are set. If not, set the day of the week and time. ▶ Page 10

Programme 1 Programme 2 Programme 3 Programme 4
DAIKIN Cora FTKM20Q2VMA - Setting mode - 1

text_image [Monday] ON OFF ON OFF 25.0°C 27.0°C 6:00 8:30 17:30 22:00

Setting Displays
DAIKIN Cora FTKM20Q2VMA - Setting mode - 2

flowchart
graph LR
    A["MON"] --> B["ON/OFF"]
    B --> C["6:00"]
    C --> D["Temperature"]

1. Press

  • The day of the week and the reservation number of the current day will be displayed.
  • 1 to 4 settings can be made per day.

2. Press Select to select the desired day of the week and reservation number.

- Pressing □ changes the reservation number and the day of the week.

3. Press Next .

• The day of the week and reservation number will be set.
- “ WEEKLY ” and “ ON ” blink.

4. Press Select to select the desired mode.

- Pressing Select changes the "ON" or "OFF" setting in sequence.

DAIKIN Cora FTKM20Q2VMA - Press Select to select the desired mode. - 1

flowchart
graph LR
    A["ON"] --> B["OFF"]
    B --> C["blank"]
    D["ON TIMER"] --> E["OFF TIMER"]
    E --> F["No Setting"]
  • In case the reservation has already been set, selecting "blank" deletes the reservation.
  • Proceed to STEP 9 if "blank" is selected.
  • To return to the day of the week and reservation number setting, press Back.

5. Press Next .

• The ON/OFF TIMER mode will be set.
• “WEEKLY” and the time blink.

DAIKIN Cora FTKM20Q2VMA - Press Next . - 1

WEEKLY TIMER Operation

DAIKIN Cora FTKM20Q2VMA - WEEKLY TIMER Operation - 1

text_image 27.0°C ON TUE 6:00 25.0°C Back Select Next Timer

6. Press to select the desired time.

  • The time can be set between 0:00 and 23:50 in 10-minute intervals.
  • To return to the ON/OFF TIMER mode setting, press Back
    • Proceed to STEP 9 when setting the OFF TIMER.

7. Press Next

• The time will be set.
• “ ⏻ WEEKLY ” and the temperature blink.

8. Press to select the desired temperature.

• The temperature can be set between 10.0°C and 32.0°C.
COOL or AUTO: The unit operates at 18.0°C even if it is set to 10.0°C to 17.0°C. ▶ Page 12 HEAT or AUTO : The unit operates at 30.0°C even if it is set to 31.0°C to 32.0°C. ▶ Page 12
• To return to the time setting, press Back.
- The set temperature is only displayed when the mode setting is on.

9. Press Next .

  • The temperature will be set and go to the next reservation setting.
  • The temperature is set while in ON TIMER operation, and the time is set while in OFF TIMER operation.
    • The next reservation screen will appear.
    • To continue further settings, repeat the procedure from STEP 4.

10. Press to complete the setting.

  • Be sure to direct the remote controller toward the indoor unit and check for a receiving tone and blinking of the OPERATION lamp.
  • “WEEKLY” is displayed on the LCD and WEEKLY TIMER operation is activated.
    • The TIMER lamp lights orange.

DAIKIN Cora FTKM20Q2VMA - Press to complete the setting. - 1

flowchart
graph TD
    A["Start"] --> B{Decision}
    B -->|Yes| C["Node 1"]
    B -->|No| D["Node 2"]
    C --> E["Child Icon"]
    D --> F["Circle Node"]
    E --> G["Sunlight"]
    F --> H["Circle Node"]

Display

- A reservation made once can be easily copied and the same settings used for another day of the week. Refer to Copy mode ▶ Page 26

NOTE

Notes on WEEKLY TIMER operation

  • Do not forget to set the clock on the remote controller first. ▶ Page 10
  • The day of the week, ON/OFF TIMER mode, time and set temperature (only for ON TIMER mode) can be set with the WEEKLY TIMER. Other settings for the ON TIMER are based on the settings just before the operation.
  • WEEKLY TIMER and ON/OFF TIMER operation cannot be used at the same time. The ON/OFF TIMER operation has priority if it is set while WEEKLY TIMER is still active. The WEEKLY TIMER will enter the standby state, and “WEEKLY” will disappear from the LCD. When the ON/OFF TIMER is up, the WEEKLY TIMER will automatically become active.
  • Only the time and set temperature with the WEEKLY TIMER are sent with the ☐. Set the WEEKLY TIMER only after setting the operation mode, the airflow rate and the airflow direction ahead of time.
  • Turning off the circuit breaker, power failure, and other similar events will render operation of the indoor unit's internal clock inaccurate. Reset the clock. ▶Page 10
  • Back can be used only for the time and temperature settings. It cannot be used to go back to the reservation number.

DAIKIN Cora FTKM20Q2VMA - Notes on WEEKLY TIMER operation - 1

text_image WEDNES 27.0°C ON TUE 8:00 25.0°C Copy Select Timer

Copy mode

- A reservation made once can be copied to another day of the week. The whole reservation of the selected day of the week will be copied.

DAIKIN Cora FTKM20Q2VMA - Copy mode - 1

text_image Programme 1 Programme 2 Programme 3 Programme 4 ON OFF ON OFF [Monday] 25.0°C 27.0°C 6:00 8:30 17:30 22:00 COPY

DAIKIN Cora FTKM20Q2VMA - Copy mode - 2

text_image Programme 1 Programme 2 Programme 3 Programme 4 [Tuesday] ON OFF ON OFF to [Friday] 25.0°C 27.0°C 6:00 8:30 17:30 22:00

DAIKIN Cora FTKM20Q2VMA - Copy mode - 3

flowchart
graph LR
    A["Setting Displays"] --> B["Confirmation"]
    B --> C["CopyPaste Normal"]
    C --> D["Final confirmation"]
  1. Press
  2. Press Select to confirm the day of the week to be copied.
  3. Press Copy

- The whole reservation of the selected day of the week will be copied.

  1. Press Select to select the destination day of the week.
  2. Press Copy

  3. The reservation will be copied to the selected day of the week. The whole reservation of the selected day of the week will be copied.
    • To continue copying the settings to other days of the week, repeat STEP 4 and STEP 5.

  4. Press ☐ to complete the setting.

- “WEEKLY” is displayed on the LCD and WEEKLY TIMER operation is activated.

NOTE

Note on COPY MODE

- The entire reservation of the source day of the week is copied in the copy mode.

In the case of making a reservation change for any day of the week individually after copying the content of weekly reservations, press and change the settings in the steps of Setting mode. ▶ Page 24

DAIKIN Cora FTKM20Q2VMA - Note on COPY MODE - 1

WEEKLY TIMER Operation

DAIKIN Cora FTKM20Q2VMA - WEEKLY TIMER Operation - 1

text_image ON 27.0°C ON TUE 6:00 25.0°C Weekly Select Next Timer

Confirming a reservation

• The reservation can be confirmed.

DAIKIN Cora FTKM20Q2VMA - Confirming a reservation - 1

text_image Setting Displays TUE 15:30 Normal ON 6:00 TUE 25.0c Confirmation

1. Press

- The day of the week and the reservation number of the current day will be displayed.

2. Press to select the day of the week and the reservation number to be confirmed.

  • Pressing Select displays the reservation details.
  • To change the confirmed reserved settings, select the reservation number and press Next. The mode is switched to setting mode. Proceed to Setting mode STEP 4. ▶ Page 24

3. Press to exit the confirmation mode.

  • “WEEKLY” is displayed on the LCD and WEEKLY TIMER operation is activated.
    • The TIMER lamp lights orange.

DAIKIN Cora FTKM20Q2VMA - Press to exit the confirmation mode. - 1

flowchart
graph TD
    A["Start"] --> B{Decision}
    B -->|Yes| C["User Icon"]
    B -->|No| D["Process Step"]
    D --> E["End"]

Display

To deactivate WEEKLY TIMER operation

DAIKIN Cora FTKM20Q2VMA - To deactivate WEEKLY TIMER operation - 1

Weekly sser while “ ⚙ WEEKLY ” is displayed on the LCD.

  • “ Ⓧ WEEKLY ” disappears from the LCD.
    • The TIMER lamp goes off.
    • To reactivate the WEEKLY TIMER operation, press □ again.
  • If a reservation deactivated with ☐ is activated once again, the last reservation mode will be used.

NOTE

- If not all the reservation settings are reflected, deactivate the WEEKLY TIMER operation once. Then press ☐ again to reactivate the WEEKLY TIMER operation.

DAIKIN Cora FTKM20Q2VMA - NOTE - 1

text_image ON 27.0°C A OFF/WHM ON 6:00 TUE 25.0°C Weekly Next Select Timer

To delete reservations

An individual reservation

1. Press

- The day of the week and the reservation number will be displayed.

2. Press to select the day of the week and the reservation number to be deleted.

3. Press Next

- “ WEEKLY ” and “ ON ” or “ OFF ” blink.

4. Press until no icon is displayed.

- Pressing changes the ON/OFF TIMER mode in sequence.

- Selecting "blank" will cancel any reservation you may have.

DAIKIN Cora FTKM20Q2VMA - Press until no icon is displayed. - 1

flowchart
graph LR
    A["ON"] --> B["OFF"]
    B --> C["blank"]
    D["ON TIMEROFF TIMER"] --> E["No Setting"]

5. Press Next .

- The selected reservation will be deleted.

6. Press

- If there are still other reservations, WEEKLY TIMER operation will be activated.

Reservations for each day of the week

  • This function can be used for deleting reservations for each day of the week.
  • It can be used while confirming or setting reservations.

1. Press Select to select the day of the week to be deleted.

2. Hold for about 5 seconds.

- The reservation of the selected day of the week will be deleted.

All reservations

Hold Weekly for about 5 seconds with the normal display.

  • Be sure to direct the remote controller toward the indoor unit and check for a receiving tone.
  • This operation cannot be used for the WEEKLY TIMER setting display.
  • All reservations will be deleted.

Care and Cleaning

DAIKIN Cora FTKM20Q2VMA - Care and Cleaning - 1

CAUTION

  • Before cleaning, be sure to stop the operation and turn off the circuit breaker.
  • Do not touch the aluminum fins of the indoor unit. If you touch those parts, this may cause an injury.

■ Quick reference
DAIKIN Cora FTKM20Q2VMA - CAUTION - 1

text_image Cleaning parts Front panel • Wipe it with a soft damp cloth. If dirty ▶ Page 30 Air filter

Air filter

• Vacuum dust or wash the filter.

Once every 2 weeks

Page 31

Indoor unit and Remote controller

- Wipe them with a soft cloth.

If dirty

Deodorizing filter (enzyme blue)

To purchase the filters (Table 1) or to purchase the another type, contact the dealer where you bought the air conditioner. The method of cleaning and replacement of the filters may differ depending on the model. Refer to the label attached to the separately sold filters themselves.

Table 1

Item Part No.
Air quality filter (enzyme blue with PM 2.5) - without frame (set of 2)BAFP094A43
Deodorizing filter (enzyme blue) - without frame (set of 2)BAFP094A41
Dust collection filter (PM 2.5) - without frame (set of 2)BAFP046A41
Titanium apatite deodorizing filter - without frame (set of 2)KAF970A46

Deodorizing filter (enzyme blue), Titanium apatite deodorizing filter.

• Vacuum dust or replace the filter. [Cleaning] [Replacement]

Once every 6 months

Once every 3 years

Page 32

Air quality filter (enzyme blue with PM 2.5), Dust collection filter (PM 2.5)

- No cleaning is required. Please replace the filter every 6 months. ▶ Page 32

NOTE

For cleaning, do not use any of the following:

• Water hotter than 40.0°C
• Volatile liquid such as benzene, petrol and thinner
- Polishing compounds
- Rough materials such as a scrubbing brush

DAIKIN Cora FTKM20Q2VMA - NOTE - 1

natural_image Illustration of a kettle, a beaker with a grater, and a bottle labeled 'Benzene' (no text or symbols on objects)

DAIKIN Cora FTKM20Q2VMA - NOTE - 2

CAUTION

  • When removing or attaching the front panel, stand on a solid, stable base and take care not to fall.
  • When removing or attaching the front panel, support the panel securely with your hand to prevent it from falling.

■ Front panel

1. Open the front panel.

- Hold the front panel by the panel tabs on the 2 sides and open it.

DAIKIN Cora FTKM20Q2VMA - Open the front panel. - 1

text_image Panel tab

2. Remove the front panel.

- Slide the front panel to either the left or right and pull it toward you. This will disconnect the front panel shaft on one side.

DAIKIN Cora FTKM20Q2VMA - Remove the front panel. - 1

text_image 2) Pull Front panel shaft 1) Slide 2) Pull 1) Slide

- Disconnect the front panel shaft on the other side in the same manner.

3. Clean the front panel.

  • Wipe it with a soft damp cloth.
  • Only neutral detergent may be used.
  • In case of washing the panel with water, wipe it with a dry soft cloth, and let it dry in the shade after washing.

4. Attach the front panel.

- Align the front panel shaft on the left and right of the front panel with the grooves, then push them all the way in.

DAIKIN Cora FTKM20Q2VMA - Attach the front panel. - 1

text_image Front panel shaft Groove

5. Close the front panel slowly.

- Press the front panel at both sides and thecentre.

DAIKIN Cora FTKM20Q2VMA - Close the front panel slowly. - 1

natural_image Illustration of a car air conditioner with airflow arrows indicating airflow direction (no text or symbols)

- Make sure that the front panel is securely fixed.

Care and Cleaning

Air filter

1. Open the front panel. ▶ Page 30

DAIKIN Cora FTKM20Q2VMA - Open the front panel. ▶ Page 30 - 1

natural_image Diagram of an air conditioner unit showing airflow direction and component layout (no text or symbols)

2. Pull out the air filters.

- Push the filter tab at the centre of each air filter a little upwards, then pull it down.

DAIKIN Cora FTKM20Q2VMA - Pull out the air filters. - 1

text_image 1) Push 2) Pull down

3. Wash the air filters with water or clean them with a vacuum cleaner.

- It is recommended to clean the air filters every 2 weeks.

DAIKIN Cora FTKM20Q2VMA - Wash the air filters with water or clean them with a vacuum cleaner. - 1

natural_image Illustration of hands holding a grid-based device with a tool, no text or symbols visible

If the dust does not come off easily

  • Wash the air filters with neutral detergent thinned with lukewarm water, then let them dry in the shade.
  • Be sure to remove the filter (small). Refer to "Filter (small)" on the next page.

DAIKIN Cora FTKM20Q2VMA - If the dust does not come off easily - 1

natural_image Simple line drawing of a basin with a rectangular dish on top (no text or symbols)
  1. Set the filters as they were.
  2. Close the front panel slowly.

Page 30

DAIKIN Cora FTKM20Q2VMA - If the dust does not come off easily - 2

natural_image Illustration of a car with four downward arrows indicating airflow or cooling process (no text or symbols)

■ Filter (small)

* For the applicable filter type, please refer to ▶ Page 29.

Attaching

  1. Open the front panel and pull out the air filters. ▶ Page 31

  2. Insert the filter.

- Check that the filters are inserted securely under the tabs.

DAIKIN Cora FTKM20Q2VMA - Attaching - 1

text_image Claw Filter (small)

Cleaning and Replacement

  1. Open the front panel and pull out the air filters. ▶ Page 31

  2. Take off the filter.

- Hold the recessed parts of the frame and unhook the 4 claws.

- Remove the filters from the tabs.

DAIKIN Cora FTKM20Q2VMA - Cleaning and Replacement - 1

text_image Claw Filter (small)

NOTE

• Operation with dirty filters:

- cannot deodorise the air,

- cannot clean the air,

– results in poor cooling,

- may cause odour.

- Dispose of old filters as non-flammable waste.

  1. Clean or replace.

[Cleaning]

Deodorizing filter (enzyme blue) : Blue / Titanium apatite deodorizing filter : Blue-Black

3-1 Vacuum dust, and soak in lukewarm water or water for about 10 to 15 minutes if very dirty.

3-2 After washing, shake off remaining water and let them dry in the shade.

- This filter can be renewed by washing it with water once every 6 months and we recommend replacing it once every 3 years.

- Do not wiring out the filter when removing water from it.

Air quality filter (enzyme blue with PM 2.5) : Blue-White / Dust collection filter (PM 2.5) : White

- Do not wash the filters as this will reduce their efficiency.

- It is recommended to replace it once every 6 months.

[Replacement]

Remove the filter from the filter frame and prepare a new one.

- Do not throw away the filter frame.

- Reuse the filter frame when replacing the filter.

- When attaching the filter, check that the filter is properly set in the tabs.

DAIKIN Cora FTKM20Q2VMA - NOTE - 1

  1. Set the filters as they were and close the front panel.

- Press the front panel at both sides and the center.

Care and Cleaning

■ Prior to a long period of non-use

1. Operate the FAN mode for several hours on a fine day to dry out the inside.

  • Press Mode and select "♣".
  • Press On/Off and start the operation.

2. After operation stops, turn off the circuit breaker for the room air conditioner.

3. Take out the batteries from the remote controller.

■ We recommend periodical maintenance

  • In certain operating conditions, the inside of the air conditioner may get foul after several seasons of use, resulting in poor performance. It is recommended to have periodical maintenance by a specialist in addition to regular cleaning by the user.
  • For specialist maintenance, please contact the dealer where you bought the air conditioner.
  • The maintenance cost must be borne by the user.

FAQ

Indoor unit

The flaps do not start swinging immediately.

- The air conditioner is adjusting the position of the flaps. The flaps will start moving soon.

DAIKIN Cora FTKM20Q2VMA - The flaps do not start swinging immediately. - 1

natural_image Line drawing of a wall-mounted air conditioner unit (no text or symbols)

Operation does not start soon.

■ When was pressed soon after operation was stopped.

■ When the mode was reselected.

• This is to protect the air conditioner. You should wait for about 3 minutes.

Different sounds are heard.

■ A sound like flowing water

  • This sound is generated because the refrigerant in the air conditioner is flowing.
  • This is a pumping sound of the water in the air conditioner and can be heard when the water is pumped out from the air conditioner during COOL or DRY operation.
  • The refrigerant flows in the air conditioner even if the air conditioner is not working when the indoor units in other rooms are in operation.

■ Blowing sound

- This sound is generated when the flows of the refrigerant in the air conditioner is switched over.

■ Ticking sound

- This sound is generated when the cabinet and frame of the air conditioner slightly expand or shrink as a result of temperature changes.

■ Whistling sound

- This sound is generated when refrigerant flows during defrosting operation.

■ Clicking sound during operation or idle time

- This sound is generated when the refrigerant control valves or the electrical parts operate.

■ Clopping sound

- This sound is heard from the inside of the air conditioner when the exhaust fan is activated while the room doors are closed. Open the window or turn off the exhaust fan.

■ Rotating machinery causes sound

  • Sound is heard when the vertical swing flaps and the horizontal swing flaps move.
  • When the air conditioner is operating in a quiet environment and the airflow rate of the indoor unit is set to Quiet Mode or Low Mode, the motion of the swing flaps may cause sound.

Outdoor unit

The outdoor unit emits water.

In COOL or DRY operation

- Moisture in the air condenses into water on the cool surface of the outdoor unit piping and drips.

DAIKIN Cora FTKM20Q2VMA - In COOL or DRY operation - 1

natural_image Line drawing of a large industrial air conditioning unit with cooling fins and ventilation grilles (no text or symbols)

Troubleshooting

Before making an inquiry or a request for repair, please check the following.

If the problem persists, consult your dealer.

DAIKIN Cora FTKM20Q2VMA - Troubleshooting - 1

Not trouble

These cases are not troubles.

DAIKIN Cora FTKM20Q2VMA - Not trouble - 1

Check

Please check again before requesting repairs.

The air conditioner does not operate

Case Description / what to check
OPERATION lamp is off.Has the circuit breaker been tripped or the fuse blown?Is there a power failure?Are batteries set in the remote controller?
OPERATION lamp is blinking.Turn off the power with the circuit breaker and restart operation with the remote controller.If the OPERATION lamp is still blinking, check the error code and consult your dealer.

The air conditioner suddenly stops operating

Case Description / what to check
OPERATION lamp is on.To protect the system, the air conditioner may stop operating after sudden large voltage fluctuations. It automatically resumes operation in about 3 minutes.
OPERATION lamp is blinking.Is there anything blocking the air inlet or air outlet of the indoor unit or outdoor unit? Stop operation and after turning off the circuit breaker, remove the obstruction. Then restart operation with the remote controller. If the OPERATION lamp is still blinking, check the error code and consult your dealer. ▶ Page 38

The air conditioner does not stop operating

Case Description / what to check
The air conditioner continues operating even after operation is stopped.☑ Immediately after the air conditioner is stopped• The outdoor unit fan continues rotating for about another 1 minute to protect the system.• While the air conditioner is not in operation• When the outdoor temperature is high, the outdoor unit fan may start rotating to protect the syste.

The room does not cool down

Case Description / what to check
Air does not come out.When the air conditioner operates immediately after the circuit breaker is turned onThe air conditioner is preparing to operate. Wait for about 3 to 15 minutes.
Air does not come out / Air comes out.Is the airflow rate setting appropriate?Is the airflow rate setting low, such as “Indoor unit quiet” or “1”? Increase the airflow rate setting.Is the set temperature appropriate?Is the adjustment of the airflow direction appropriate?
Air comes out.Is there any furniture directly under or beside the indoor unit?Is the air conditioner in ECONO operation or OUTDOOR UNIT QUIET operation?Are the air filters dirty?Is there anything blocking the air inlet or air outlet of the indoor unit or outdoor unit?Is a window or door open?Is an exhaust fan turning?

Mist comes out

Case Description / what to check
Mist comes out of the indoor unit.This happens when the air in the room is cooled into mist by the cold airflow during COOL or other operation.

Remote controller

Case Description / what to check
The unit does not receive signals from the remote controller or has a limited operating range.The batteries may be exhausted.Replace both batteries with new dry batteries AAA.LR03 (alkaline).For details, refer to “Preparation Before Operation”. ▶Page 9Signal communication may be disabled if an electronic-starter-type fluorescent lamp (such as inverter-type lamps) is in the room. Consult your dealer if that is the case.The remote controller may not function correctly if the transmitter is exposed to direct sunlight.
LCD is faint, is not working, or the display is erratic.The batteries may be exhausted.Replace both batteries with new dry batteries AAA.LR03 (alkaline).For details, refer to “Preparation Before Operation”. ▶Page 9
Other electric devices start operating.If the remote controller activates other electric devices, move them away or consult your dealer.

Air has an odour

Case Description / what to check
The air conditioner gives off an odour.The room odour absorbed in the unit is discharged with the airflow.We recommend you to have the indoor unit cleaned. Please consult your dealer.

Others

Case Description / what to check
The air conditioner suddenly starts behaving strangely during operation.The air conditioner may malfunction due to lightning or radio.If the air conditioner malfunctions, turn off the power with the circuit breaker and restart the operation with the remote controller.
The ON/OFF TIMER does not operate according to the settings.Check if the ON/OFF TIMER and the WEEKLY TIMER are set to the same time.Change or deactivate the settings in the WEEKLY TIMER. ▶ Page 23

Notes on the operating conditions

  • If operation continues under any conditions other than those listed in the table,
    – A safety device may activate to stop the operation.
  • Dew may form on the indoor unit and drip from it when COOL or DRY operation is selected.
ModeOperating conditions
DRYOutdoor temperature : -10.0-46.0°CIndoor temperature : 18.0-32.0°CIndoor humidity : 80% max.
COOLOutdoor temperature : -10.0-46.0°CIndoor temperature : 18.0-32.0°CIndoor humidity : 80% max.

Troubleshooting

■ Call your dealer immediately

DAIKIN Cora FTKM20Q2VMA - ■ Call your dealer immediately - 1

WARNING

When an abnormality (such as a burning smell) occurs, stop operation and turn off the circuit breaker.

  • Continued operation in an abnormal condition may result in troubles, electric shocks or fire.
  • Consult the dealer where you bought the air conditioner.

Do not attempt to repair or modify the air conditioner by yourself.

  • Incorrect work may result in electric shocks or fire.
  • Consult the dealer where you bought the air conditioner.

If one of the following symptoms takes place, call your dealer immediately.

  • The power cord is abnormally hot or damaged.
  • An abnormal sound is heard during operation.
  • The circuit breaker, a fuse, or the earth leakage circuit breaker cuts off the operation frequently.
  • A switch or a button often fails to work properly.
    • There is a burning smell.
    • Water leaks from the indoor unit.

Turn off the circuit breaker and call your dealer.

DAIKIN Cora FTKM20Q2VMA - WARNING - 1

■ After a power failure
- The air conditioner automatically resumes operation in about 3 minutes. You should just wait for a while.
Lightning
- If there is a risk lightning could strike in the neighbourhood, stop operation and turn off the circuit breaker to protect the system.

■ Disposal requirements

- Dismantling of the unit, handling of the refrigerant, oil and other parts, should be done in accordance with the relevant local and national regulations.

DAIKIN Cora FTKM20Q2VMA - ■ Disposal requirements - 1

text_image ON 88 STD ON OFF ON MONTLEWED THUFRI SATSUN ON 38:88 ON 38:88 Cancel Timer

■ Fault diagnosis by remote controller

- The remote controller can receive relevant error codes from the indoor unit.

  1. When is held down for about 5 seconds, "00" blinks in the temperature display section.

  2. Press repeatedly until a continuous beep is produced.

- The code indication changes as shown below, and notifies you with a long beep.

CODE MEANING
SYSTEM00NORMAL
UAINDOOROUTDOOR UNIT COMBINATION FAULT
U0REFRIGERANT SHORTAGE
U2DROP VOLTAGE OR MAIN CIRCUIT OVERVOLTAGE
U4FAILURE OF TRANSMISSION (BETWEEN INDOOR UNIT AND OUTDOOR UNIT)
INDOOR UNITA1INDOORPCB DEFECTIVENESS
A5HIGH PRESSURE CONTROL OR FREEZE-UP PROTECTOR
A6FAN MOTOR FAULT
C4FAULTY HEAT EXCHANGER TEMPERATURE SENSOR
C9FAULTY SUCTION AIR TEMPERATURE SENSOR
OUTDOOR UNITEACOOLING-HEATING SWITCHING ERROR
E1CIRCUIT BOARD FAULT
E5OL STARTED
E6FAULTYCOMPRESSOR START UP
E7DC FAN MOTOR FAULT
E8OVERCURRENT INPUT
F3HIGH TEMPERATURE DISCHARGE PIPE CONTROL
F6HIGH PRESSURE CONTROL (IN COOLING)
H0 SENSOR FAULT
H6OPERATION HALT DUE TO FAULTY POSITION DETECTION SENSOR
H8 DC CURRENT SENSOR FAULT
H9FAULTY SUCTION AIR TEMPERATURE SENSOR
J3FAULTY DISCHARGE PIPE TEMPERATURE SENSOR
J6FAULTY HEAT EXCHANGER TEMPERATURE SENSOR
L3ELECTRICAL PARTS HEAT FAULT
L4HIGH TEMPERATURE AT INVERTER CIRCUIT HEATSINK
L5OUTPUT OVERCURRENT
P4FAULTY INVERTER CIRCUIT HEATSINK TEMPERATURE SENSOR

NOTE

  • A short beep and 2 consecutive beeps indicate non-corresponding codes.
  • To cancel the code display, hold □ down for about 5 seconds. The code display also clears if no button is pressed for 1 minute.

Quick Reference

DAIKIN Cora FTKM20Q2VMA - Quick Reference - 1

flowchart
graph TD
    A["Top Panel: Air Condition"] --> B["On/Off AN"]
    B --> C["Mode"]
    B --> D["Swing"]
    B --> E["ON"]
    E --> F["27.0°C"]
    F --> G["MON 15:30"]
    G --> H["18°C → 32°C"]
    I["Bottom Panel: Weather Control"] --> J["Mode"]
    J --> K["% RH"]
    K --> L["Recovery to Air"]
    L --> M["Recovery to Air"]
    M --> N["Recovery to Air"]

DAIKIN INDUSTRIES, LTD.

Head office:

Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,

Kita-ku, Osaka, 530-8323 Japan

Tokyo office:

JR Shinagawa East Bldg., 2-18-1, Konan,

Minato-ku, Tokyo, 108-0075 Japan

https://www.daikin.com

DAIKIN Cora FTKM20Q2VMA - DAIKIN INDUSTRIES, LTD. - 1

The two-dimensional bar code is a manufacturing code.

Table of contents Click a title to access it
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : DAIKIN

Model : Cora FTKM20Q2VMA

Category : Air-conditioner